1. Model MP 4R and MP 4RSS  MULTI PAK    RESCUE AIR CARTS    Manual No  PAK013   Rev 1 January 2001     SYSTEMS  INTERNATIONAL       Operating Manual       AIRSYSTEMS INTERNATIONAL  INC   829 Juniper Crescent  Chesapeake  Va    23320   Telephone  757  424 3967  Toll Free 1 800 866 8100  Fax No   757  424 5348  http   www airsystems cc  e mail  sales airsystems cc       Printed in U S A  Air Systems International  Inc    Copyright Air Systems International  Inc  2000  All Rights Reserved   Registered to ISO 9001  Certificate No  A5033    Table of Contents    M  ssen  m                                                                             3  SECU OP er ALO PETRI T II IT TT 4 5  Cylinde  r CAN GG M                                               6  SU  PA 6  High Pressure Airline General Maintenance  amp  Inspection               csscssssccsssccsssscsssescssssesesees 6  Parts POENPMICALION e L                                           7    Warranty di ny os casscsciicscsavescssstcessvecssscacsovesivsseteavsctssteseuensetstanesauvsascaseseutsecacspaesesbsiivsnoaeabaees 8    Specifications    5 H x20 5 W x15  D  Handle collapsed     Bleeder Valves  Allows depressurization of hand tight nut  Check Valves  Allows independent cylinder operation    Pneumatic   set at approximately 500psi  Whistle   34 5 bar  descending pressure  MN 0   5500psi  379 bar  inlet   Primary Regulator  0   125psi 8 6 bar  discharge   80cfm  2260 LPM    125psi  8 6 bar   Flow Rate  discharge pressure    Sec
2. e gauge pressure to assure that it is full    2  Index the selector valve towards the full cylinder    3  Close the drained cylinder valve and open the corresponding bleeder valve to relieve  pressure on the hand tight nut    4  Remove the drained cylinder and install a full cylinder in its place  Connect the CGA 347  hand tight nut to the cylinder valve  close the bleeder valve on the connect whip  It is  now ready for use when the other cylinder pressure descends to 500psi or lower    Note  The system is equipped with check valves that will prevent back flow from the other cylin  der in use     Shutdown  Make sure all personnel have egressed the hazardous area and have disconnected from the  breathing air system     1 Close cylinder valves    2 Depressurize manifold by pulling the relief valve ring    3 Close the regulator by turning the control knob counterclockwise    4  Disconnect airline hoses and reinstall dust caps    5  Remove connections from cylinders and reinstall cylinder valve covers  if applicable      High Pressure Airline General Maintenance   amp  Inspection    Monthly  1  Check regulators  gauges  and valves for external leakage     2  Inspect cylinder valves for proper closure   3  Check cylinder pigtails for cleanliness  flexibility  wear  leakage  blisters on hose  thread  damage  and O rings on CGA fittings  Replace damaged items immediately     Annually  1  Check relief valve s pressure setting     2  Check regulator function by opening and closing reg
3. hough Air Systems International believes that its  products  if operated and maintained as shipped from the factory and in accordance with our    op   erations manual     conform to OSHA and or MSHA requirements  there are no implied or expressed  warranties of such compliance extending beyond the limited warranty described herein  Product  designs and specifications are subject to change without notice  Rev 2 12 98    Air leaks are not covered under warranty except when they result from a defective system  component  i e  an on off valve or regulator or upon initial delivery due to poor workman   ship  Air leaks due to poor delivery or damage will be covered under delivery claims  Minor  air leaks are part of routine service and maintenance and are the responsibility of the cus   tomer just as are filters and oil changes     
4. ondary 0   300ps1 20 6 bar  inlet  Regulator  Pressure  0   125 ps1 8 6 bar  discharge   0 125psi inlet 0 125psi outlet   Minimum flow rate  5cfm  100psi inlet  Secondary pressure and 80 psi outlet  Regulator Maximum flow rate  18cfm 100psi inlet  Flow Rate  pressure and 70 outlet    Relief Valve  125psi 8 6 bar  ASME preset  Four  4  quick connect fittings    Intrinsically Safe   No electronic devices       Setup Operation A    STEP 1   Install cylinders on cart  Secure cylinders by tightening the straps at the buckle    and mate the velcro sections to prevent slipping  2216psi  153 bar  or 4500psi zr    310 bar  cylinders can be used  v  STRAP  HAND     TIGHT  STEP 2  he    Install universal CGA 347 hand tight nuts to the cylinder valves and tighten  E  Insure both bleeder valves are closed by turning fully clockwise  E  BLEEDER VALVES    STEP 3  ia  Open one cylinder       SELECTOR VALVE  STEP 4     Index the selector valve so that it points to the open cylinder  At this time  the  low pressure warning alarm will sound until it sets itself at approximately  1000psi  69 bar   Check reading on gauge to verify that it is full  Close the  cylinder UE    REGULATOR   CONTROL KNOB  STEP 5  LOW PRESSURE ALARM TEST  Set the required respirator pressure with the regulator control knob  and bleed the pressure at either the relief valve or by partially  engaging a male plug into one of the respirator couplings  This         L  depressurizes the manifold and simulates low cvlinder pres
5. sure  A  The low pressure warning alarm will sound at approximatelv lm    500psi  35bar    7 p s 7  RELIEF VALVE RESPIRATOR      COUPLING             AUXILIARY INLET    STEP 6  SORT    Index the selector valve toward the other cylinder and open the  cylinder valve  At this time the low pressure warning alarm will  resound until it sets itself at approximately 1000psi  69 bar   Check 2  reading on gauge to verify cylinder is full  Either cylinder can    im  el  now be selected for operation  EG rs    Optional   Install high pressure connect whip to auxiliary inlet port  CGA   347   This step can be done after Step 6 or anytime during the  operation of the system  This auxiliary inlet port is not controlled  by the selector valve  Auxiliary inlet air directly feeds the regula   tor system        STEP 7          Couple respirators and lengths of hoses to the manifold and read  o l  just pressure regulator if necessarv  The svstem is now opera  B  tional     A KK  Optional             If pneumatic equipment is to be used which requires a different  pressure than the respirators  set the secondary low pressure regu   lator accordingly  This is a locking regulator  push to lock  pull  to unlock        Cylinder Change    When the cylinder in use has been depleted to approximately 500psi  35bar   the low pressure  warning alarm will sound indicating that the cylinder needs to be replaced    To change a cylinder while the cart is still in use    1  Open the second cylinder and note th
6. ulator valve knob fully     Every 4 years  1  Replace all flexible pigtails   consult factory     Parts Identification    ITEM   DESCRIPTION PART    HDWRI113A  QDH3SL4M   5A QDSSL4M    QDH3DCAP   6A QDSDCAP   7 GA15160B  8   SECONDARY PRESSURE REGULATOR    WLOI3    9   OUTLET PRESSURE GAUGE   GA20160B            Warranty Disclaimer  Air Systems    manufactured equipment is warranted to the original user against defects in workman   ship or materials under normal use for one year after date of purchase  Any part which is deter   mined by Air Systems to be defective in material or workmanship will be  as the exclusive remedy   repaired or replaced at Air Systems    option  This warranty does not apply to electrical systems or  electronic components  Electrical parts are warranted  to the original user  for 90 days from the  date of sale  During the warranty period  electrical components will be repaired or replaced at Air  Systems    option   NO OTHER WARRANTY  EXPRESSED OR IMPLIED  AS TO DESCRIPTION  QUAL   ITY  MERCHANTABILITY  FITNESS FOR A PARTICULAR PURPOSE  OR ANY  OTHER MATTER IS GIVEN BY AIR SYSTEMS IN CONNECTION HEREWITH  UN   DER NO CIRCUMSTANCES SHALL THE SELLER BE LIABLE FOR LOSS OF  PROFITS  ANY OTHER DIRECT OR INDIRECT COSTS  EXPENSES  LOSSES OR  DAMAGES ARISING OUT OF DEFECTS IN  OR FAILURE OF THE PRODUCT OR  ANY PART THEREOF   The purchaser shall be solely responsible for compliance with all applicable Federal  State and  Local OSHA and or MSHA requirements  Alt
    