Home
UP200-GSM Manual - DuPol - GSM Door Phone, GSM Intercom
Contents
1. Call time sec 120 OUT activation time sec 5 RELAY activation time sec 3 Incoming SMS Forwarding 00363011111111 Gate controling Recorded users Phone numbe 00363011111111 4 100 VIRELAY OUT New user Phone number VIRELAY OUT Add new Status information Intercom GSM network state messages Module type UP200 GSM GSM signal 0 31 19 Call Finished 4 Firmware version 1 16 GSM provider T Mobile H Call Stop in ring state Auto call enabled Start call secondary 00362077777777 Inputs Outputs Reset to primary nr 1JOutgoing call Upper button IDLE RELAY IDLE started Call Finished p Lower button IDLE OUT IDLE Call Stop in ring state INPUT IDLE Config save OK UP200 GSM Rev 1 2 08 01 2014 Administration operations These menu items serve for reading writing saving etc the settings Read Click to read and displays the settings from the unit Write Click to write the settings to the unit s memory Read Write Write Save Open Save Click to save the settings to file Open Click to open saved settings from file Firmware Click to update the intercom s firmware English Magyar Click to change the ntercom configurator s interface language Me Progress bar Buttons The intercom unit calls the phone numbers entered here when the appropriate button is pressed If both phone numbers are set to any button the unit calls the primary phone number first In case
2. GSM850 EGSM900 DCS1800 PCS1900 Dimensions height 165mm width 122mm depth 40mm Package contents e UP200 GSM e GSM 900MHZ 1800MHz antenna e Antenna bracket fixing screws UP200 GSM Rev 1 2 08 01 2014
3. INTRODUCTION The UP200 GSM is an intercom unit which as a cell phone can call the owner s mobile or landline phone By pressing the call button on the intercom it makes the voice connection in a few seconds just like when talking via a conventional intercom system This way it makes possible for the owner to receive the visitor s calls and talk to them at anytime and anywhere even when not at home The unit does not need any special installation or complicated wiring it needs power only and an active SIM card FUNCTIONS e Wireless intercom with 2 pushbuttons for 1 or 2 apartments e 2 phone numbers can be assigned to each pushbutton set as primary and secondary e Gate control function by free call 100 user phone numbers can be configured e Direct control for electric lock can be controlled during the conversation using the phone s keys e The output can be activated by pushing the unit s call button existing doorbell can be connected e The outputs can be controlled by the contact input optional button for local control of the electric lock e SMS forwarding e g to forward the balance information of pre pay SIM card e Configuring via USB using the PC software found in the intercom unit e Remote configuring by SMS message UP200 GSM Intercom and access control unit operating on mobile GSM network FEATURES e Compact design all functions on 1 panel Wide power voltage range from 14V to 24V DC or AC r
4. SIM card e g balance information in case of a prepaid card to the configured phone number After forwarding the received message is deleted from the SIM card If there is no phone number configured the unit deletes the incoming messages without forwarding Status LED indications Is lit after connecting to the GSM network and reaching the sufficient GSM signal The sufficient signal is 10 on 0 31 scale Is lit continuously if the device cannot connect to the GSM network Possible reasons the GSM antenna is faulty or is not connected the SIM card is not inserted or the PIN code request is not disabled or the SIM card is faulty Communication in progress A call or conversation is in progress UP200 GSM Rev 1 2 08 01 2014 SETTING WITH MS WINDOWS APPLICATION The intercom unit parameters phone numbers controls can be configured using the Intercom configurator software found on the internal storage of the device You can run the program directly from the unit s drive after connecting to USB Widows XP and Windows 7 compatible HF Intercom configurator V1 00 g X Be llit sok Upper button Primary phone number 00363011111111 Secondary phone number 00362077777777 lZ Automatic rite Lower button Save Primary phone number 00367033333333 Secondary phone number Automatic Control of outputs OUT INPUT NO RELAY Push button NO English v General settings Ring time sec 20
5. an be configured e controlling by the pushbutton the relay activates when the call button is pushed e g possibility to connect an existing door bell e controlling by the INPUT contact input the relay activates on external contact e g garage door opening or closing e controlling by the phone s while in call by pressing 1 of the phone s numbered keys the relay activates for the configured time period ATTENTION The RELAY and OUT outputs is activated in parallel and independently from each other by both menu items the Control of outputs and the Gate control Please take this into consideration when planning the usage CALL IN PROGRESS red Voltage output activated RELAY red Relay output activated Controlling the voltage output The OUT voltage output can be controlled as follows e controlling by the INPUT contact input after activating the input the output activates for the configured time period e g optional indoor pushbutton for electric lock control e controlling by the phone s keys while in call by pressing 2 of the phone s numbered keys the output activates for the configured time period e g direct control of the electric lock The voltage output is protected against short circuit and overcurrent thereby the output turns off upon overcurrent and becomes operable again after the termination of the fault Forwarding incoming SMS messages The unit forwards the SMS messages received on its
6. cter else the module does not apply the modifications The following table contains the configuring and query commands Configuration commands Password for programming default setting 1234 Changing the password The password is a 4 digit number Resetting the settings and the password to default Primary phone number for upper pushbutton Secondary phone number for upper pushbutton Seer ere rrp ate meee iamae Primary phone number for lower pushbutton Secondary phone number for lower pushbuiton In case the call to LOWTEL1 fails LOWTEL2 phone number will be called one i without having to push the button again if the parameter is ON Voltage output control OFF disable BUTTON when button is pressed INPUT when input is activated PHONE during call pressing any of the phone s keys IN PHONE INPUT and PHONE enabled OUT activation event See eee Relay control OFF disable BUTTON when button is pressed Pere rer vere INPUT when input is activated RINGTIME duration Ringing time of the telephone to restrict the reach of voice mail 10 120sec CALLTIME duration Maximum duration of the conversation 10 600 sec RTIME duration NO or NC Duration and idle mode of the relay output activation 1 120 sec OUTTIME duration NO or NC Duration and idle mode of the voltage output activation 1 120 sec Setting the phone numbers for relay or voltage output activation For output RTEL phone number REL OUT activation
7. egardless to polarity Solar powered version is available UP200 GSM S 1 contact input 1 relay output max load 1A 24V DC 1 voltage output with short circuit and overcurrent protection max power 1A 12V DC Programming port mini USB B type e Communication 2G GSM 850 EGSM 900 DCS 1800 PCS 1900 MHz e Network independent accepts any SIM card e Operating temperature 30 C 60 C e Protection IP54 APPLICATION AREA e Modern solution for wireless intercom system private homes resorts offices premises Remotely controllable access control unit Keyless door opening Garage door opening closing by phone Emergency call unit Info columns ADVANTAGES e No missed clients or visitors since the intercom unit calls the owner s mobile phone no matter where the owner is e On call the owner can let in the guest client or courier remotely e Incase of absence burglary attempts can be prevented by imitating the apparent presence e Fast and easy installation easy configuration using a PC e The solar powered version can be operated where no power supply is available e Possibility for communication from any fixed place UP200 GSM Rev 1 2 08 01 2014 OPERATION Visitor mode When the visitor pushes the call button the device initiates a voice call to the configured phone number If the called party accepts the call the communication establishes for the configured duration During the call the connectio
8. elay contact output activation time SMS forward Forwards the SMS messages received on the unit s SIM card to the specified phone number e g balance information received from the GSM service provider It is recommended to configure this in case of using a pre pay type SIM card Gate control When calling the intercom from the phone numbers specified here control of the output or outputs assigned to the given phone number is performed The incoming call is not accepted thereby this function works with free calls Maximum 100 user phone numbers can be added Status information Displays information about the switching state of the peripheries and the actual status of the mobile network State messages The messages shown in this window give information about the internal operation of the unit This helps in identifying an internal process an incorrect configuration or other malfunction The question marks placed next to the settings in the Intercom configurator give assistance to the parameter settings of the given section UP200 GSM Rev 1 2 08 01 2014 SETTING WITH SMS COMMANDS Configuration of the unit is possible by sending the appropriate commands in SMS to the module s phone number It is possible to send more commands settings in the same SMS but the length of the message must not exceed 140 characters Each message must begin with the password using the PWD password command and each command must end with chara
9. it is and all connections are done the unit can be powered up lf operated without an electric lock from a 16V AC transformer the current requirement is 300mA 5VA When operated with an electric lock the minimum power requirement is 20VA GSM antenna connector Contact input Relay contact output Voltage output Power input Speaker output Microphone input QBAY lt OQOOoWO Battery connector solar powered version only Name plate lighting USB mini B port Call pushbuttons Status LEDs SIM card case CROTORORO UP200 GSM Rev 1 2 08 01 2014 EXTRA FUNCTIONS With the help of fang ini which contains the Intercom configurator s settings the below settings can be done Changing audio settings SpkAnalog volume 0 70 default value 30 MicAnalog michrophone sensitivity 0 13 default value 10 Attention By changing the above values echoing can increase Backlight brightness Light brightness 0 10 default value 5 After changing the settings and saving ang ini it is necessary to run Intercom configurator program again and to upload the new settings on the module to validate the changes TECHNICAL SPECIFICATION Names Other conditions Minimum Typical Maximum Unit a ee een saat for 16VDC o ee A Vy DC switching Relay output load AC switching Voltage output Contact input switching 0 Operating temperature es ao S y o sO Outdoor protection PH Other data Transmission frequency
10. n cannot be interrupted nor by making a call to the device nor by pressing the button again The call is ended automatically when the configured communication time expires or the called party can hang up the call at anytime on his her phone The call is ended automatically if the called party does not answer or is not available A new call is initiated only if the button is pressed again Listen in mode The intercom unit can be called from any phone number In this case the unit accepts the call without ringing and the voice connection establishes The call can be ended on the caller s phone or by pressing the call button on the unit If the call is initiated from a phone number which is configured in the unit as gate opener number the device will consider the call as a gate opening call In this case voice connection is not established but the relay output is activated To make a listen in call from such phone number use the 31 code in front of the number this hides the caller s phone number e g 31 0036301234567 The unit will already accept the call received from unknown phone number Controlling the relay output The RELAY normally open NO relay output can be controlled as follows depending on the usage e controlling by free call on incoming call after identifying the caller ID the unit rejects the call and activates the output e g garage door or barrier opening for which max 100 user phone numbers c
11. of an unsuccessful call e g if the called number is not available or the call is not accepted calling the secondary phone number can be done by pushing the button again within 60 seconds If the Automatic option is enabled then the unit calls the secondary phone number if the primary fails without having to push the button again Control of outputs The two outputs of the unit can be controlled by multiple configured events You can choose the activation event according to the usage Control of outputs OUT Input NO RELAY Push button NO OUT The voltage output e g for direct control of an electric lock RELAY The relay contact output e g for garage door control You can select the activation event and the normal state of the output idle state from the drop down menus Upon activation the output state changes for the configured time period General settings General settings Ring time sec 20 Em Call time sec 120 caw OUT activation time sec 5 mikes RELAY activation time sec 3 Incoming SMS Forwarding 00363011111111 mm Ring time 10 120 sec The maximum time allowed for ringing from pushing the call button This function is useful to avoid switching to voicemail Call time 10 600 sec The maximum time allowed for a call initiated from the intercom OUT active time 1 120 sec monostable The voltage output activation time RELAY active time 1 120 sec monostable The r
12. supplied with the unit provides good transmission under normal reception circumstances In case of having signal strength problems and or noisy communication use other type of higher gain antenna or find a more suitable place for the antenna Inserting the SIM card pull the metallic part of the SIM case towards the center of the panel to open up the SIM slot for inserting the card Insert the SIM card into the slot so that its contact surface should point towards the contact pins of the card case when turned down as well as the cut corner of the card should fall towards the edge of the panel in the direction of the LEDs Fasten the SIM card by pulling back the metallic part of the SIM case Connection diagram INPUT RELAY OUTS 12 24V oe i temo LF fel GSM SIM ERROR fel CALL IN PROGRESS EJ Fo gog Oo hgh msg igh vane ns a om jg om E FHT SPK MIC iv a f Socol 1 ag T Putting into operation Disable PIN code request voicemail and missed call notification service on the SIM card Enable caller identification and caller ID sending service on the SIM card at the GSM service provider Make sure the SIM card is inserted properly into its case Make sure the antenna is fixed properly into the SMA connector Make sure the wires are connected as shown in the connection diagram Make sure the power supply is sufficient for the operation of the unit If
13. the suffix after the phone number is necessary REL switch the realy OUT switch the voltage out REL OUT switch both Up to 100 users RTELDEL phone number Delete the selected phone number STATUS Query of the settings except RTEL list RTEL Query of the RTEL list INFOSMS phone number Forwards the incoming SMS messages This scenario shows the configurations for the following requirements phone number 2 only for upper pushbutton auto switch to the secondary phone VOUT control for electric lock by phone and input contact duration is 10sec both phone numbers are able to control the gate control s relay by a free call relay activation time is 5sec Other call parameters Ringingtinme 25sec maximum duration of the conversation 1 20sec forwarding prepaid card information to primary phone number SMS message PWD 1234 UPTEL1 0036309999999 UPTEL1 0036201111111 UPAUTO ON OUT IN PHONE OUTTIME 1 0 NO RTEL 0036309999999 REL RTEL 0036201111171 RELARTIME 5 NO RINGTIME 25 C ALL TIME 720 INFOSMS 0036201111111 UP200 GSM Rev 1 2 08 01 2014 INSTALLATION Mounting Measure the GSM signal with your mobile phone It may happen that in the desired place of installation the signal strength is not satisfactory In this case you can move the unit or the GSM antenna in a more suitable place before installation Do not mount the unit where it could be affected by strong electromagnetic disturbances Antenna the GSM antenna