Home
1769-IN014 - Rockwell Automation
Contents
1. IN015 terminators Instructions If you would like a manual you can e download a free electronic version from the internet www ab com micrologix or www theautomationbookstore com e purchase a printed manual by contacting your local distributor or Rockwell Automation representative visiting www theautomationbookstore com and placing your order calling 1 800 963 9548 USA Canada or 001 330 725 1574 Outside USA Canada Hazardous Location Considerations This product must be installed in an enclosure This equipment is suitable for use in Class I Division 2 Groups A B C D or non hazardous locations only The following ATTENTION statement applies to use in hazardous locations EXPLOSION HAZARD ATTENTION a nn e Substitution of components may impair suitability for Class I Division 2 e Do not replace components or disconnect equipment unless power has been switched off or the area is known to be non hazardous e Do not connect or disconnect components unless power has been switched off or the area is known to be non hazardous e All wiring must comply with N E C article 501 4 b Publication 1769 1N014B EN P May 2002 4 1769 Compact 1 0 Communication Bus Expansion Cables Environnements dangereux Cet quipement est con u pour tre utilis dans des environnements de Classe 1 Division 2 Groupes A B C D ou non dangereux La mise en garde suivante s applique une utilisation
2. your system using a MicroLogix 1500 controller only one expansion cable one expansion power supply and a maximum of eight I O modules may be used gt allowing for two banks of I O modules maximum An adapter allows three banks and 30 modules maximum Publication 1769 1N014B EN P May 2002 1769 Compact 1 0 Communication Bus Expansion Cables 7 Installation Prevent Electrostatic Discharge Electrostatic discharge can damage integrated circuits or ATTENTION semiconductors if you touch bus connector pins or the terminal block Follow these guidelines when handling 1769 Compact I O components e Touch a grounded object to discharge static potential e Wear an approved wrist strap grounding device e Do not touch the bus connector or connector pins e Do not touch circuit components inside the module If available use a static safe workstation e When not in use keep cables in static shield packaging Remove Power Remove power before making or breaking cable connections ATTENTION When you remove or insert a cable connector with power applied an electrical arc may occur An electrical arc can cause personal injury or property damage by e sending an erroneous signal to your system s field devices causing unintended machine motion e causing an explosion in a hazardous environment Electrical arcing causes excessive wear to contacts on both the module and its mating connector Worn cont
3. Installation Instructions 1769 Compact 1 0 Communication Bus Expansion Cables Cat No 1769 CRR1 CRR3 CLL1 CLL3 CRL1 CRL3 Inside For More Information 2 Hazardous Location Considerations 3 Environnements dangereux 0 0 4 A A Rond tee 4 Cable Types and Lengths 5 System Configurations sses 6 Installation oo cc sescseessesecsessecseeeeeeseeees 7 Publication 1769 1N014B EN P May 2002 2 1769 Compact 1 0 Communication Bus Expansion Cables For More Information For Refer to this Document Pub No Information on how to install and use Compact 1 0 1769 ADN DeviceNet Adapter 769 IN001 your 1769 ADN Adapter Installation Instructions Installation guides for 1769 Discrete Compact 1769 IA8I Individually Isolated 120V ac 769 IN012 Compact 1 0 module 1769 IA81 Input Module Installation guides for 1769 Discrete Compact 1769 IA16 120V ac Input Module 769 IN006 Compact 1 0 module 1769 1416 Installation Instructions Installation guides for 1769 Discrete Compact 1769 OW8 AC DC Relay Output Module 769 IN051 Compact 1 0 module 1769 0W8 Installation Instructions Installation guides for 1769 Discrete Compact 1769 OW8l Individually Isolated 769 IN053 Compact 0 module 1769 OWE8l AC DC Relay Output Module Installation guides for 1769 Discrete Compact 1769 1016 24V d
4. acts may create electrical resistance Publication 1769 1N014B EN P May 2002 8 1769 Compact 1 0 Communication Bus Expansion Cables Attaching Cables e A maximum of two expansion cables may be used in a 1769 system TIP e Each I O bank requires its own power supply The 1769 cables extend the 1769 communication bus but do not extend bus power Right Cover a 1 Disconnect power 2 Check bus lever position Left cover Make sure the bus lever 4 on the left most I O module is in the unlocked fully right position Right cover Make sure the bus lever 4 on the right cover is in the unlocked fully right position 3 Use the upper and lower tongue and groove slots 1 to secure the cable cover to the module 4 Move the cable cover back along the tongue and groove slots until the bus connectors 2 line up with each other Publication 1769 1N014B EN P May 2002 1769 Compact 1 0 Communication Bus Expansion Cables 9 5 If necessary push the bus lever back slightly to clear the bus locking tab 3 Use your fingers or a small screwdriver 6 To allow communication between the module and the cable connector move the bus lever firmly to the left 4 until it clicks Ensure that it is locked firmly in place ATTENTION When attaching cables it is very important that the bus connectors are securely locked together to ensure proper electrical connection S
5. cond Street Milwaukee WI 53204 2496 USA Tel 1 414 382 2000 Fax 1 414 382 4444 Europe Middle East Africa Rockwell Automation SA NV Vorstlaan Boulevard du Souverain 36 1170 Brussels Belgium Tel 32 2 663 0600 Fax 32 2 663 0640 Asia Pacific Rockwell Automation 27 F Citicorp Centre 18 Whitfield Road Causeway Bay Hong Kong Tel 852 2887 4788 Fax 852 2508 1846 Headquarters for Dodge and Reliance Electric Products Americas Rockwell Automation 6040 Ponders Court Greenville SC 29615 4617 USA Tel 1 864 297 4800 Fax 1 864 281 2433 Europe Middle East Africa Rockwell Automation Br histraRe 22 D 74834 Elztal Dallau Germany Tel 49 6261 9410 Fax 49 6261 17741 Asia Pacific Rockwell Automation 55 Newton Road 11 01 02 Revenue House Singapore 307987 Tel 65 6356 9077 Fax 65 6356 9011 Publication 1769 1N014B EN P May 2002 PN 40071 103 01 2 Supersedes Publication 1769 1N014A US P April 2000 Copyright 2002 Rockwell Automation All rights reserved Printed in the U S A
6. ctions For Series B DeviceNet adapters only Information on how to install and use Compact 1769 IF4XOF2 8 Bit Low Resolution Analog 1769 UM008 your 1769 IF4XOF2 module 1 0 Combination Module User Manual Installation guides for 1769 High Speed Compact 1769 HSC High Speed Counter Module 769 IN030 Counter module 1769 HSC Installation Instructions For Series B DeviceNet adapters only Installation guides for 1769 Compact 1769 IT6 Thermocouple mV Input Module 769 IN026 Thermocouple mV module 1769 IT6 Installat ion Instructions Publication 1769 1N014B EN P May 2002 1769 Compact 1 0 Communication Bus Expansion Cables 3 For Refer to this Document Pub No Information on how to install and use Compact 1769 IT6 Thermocouple mV Input Module 769 UM004 your 1769 IT6 module User Manual Installation guides for 1769 Compact 1769 IR6 RTD Resistance Input Module 1769 IN027 RTD resistance module 1769 IR6 Installation Instructions Information on how to install and use Compact 1769 IR6 RTD Resistance Input Module 1769 UM005 your 1769 IR6 module User Manual Installation guides for 1769 power Compact 1769 Expansion 1 0 Power Supplies 1769 IN028 supplies Installation Instructions Installation guides for 1769 cables Compact 1 0 Communication Bus Expansion Cables 1769 IN014 Installation Instructions Installation guides for 1769 end caps and Compact 1 0 End Caps Terminators Installation 1769
7. dans des environnements dangereux DANGER D EXPLOSION ATTENTION es oes e La substitution de composants peut rendre cet quipement impropre a une utilisation en environnement de Classe 1 Division 2 e Ne pas remplacer de composants ou d connecter l quipement sans s tre assur que l alimentation est coup e e Ne pas connecter ou d connecter des composants sans s tre assur que l alimentation est coup e e Ce produit doit tre install dans une armoire Overview The 1769 CLLx CRRx and CRLx cables extend the 1769 bus communication lines A maximum of two cables can be used in a 1769 system allowing for three groups or banks of I O modules Each bank requires its own power supply See System Configurations on page 6 e Some controllers do not support three I O banks Refer to your controller s manual for details D e Some controllers provide power to the I O bank Refer to your TIP controllers manual for details Publication 1769 IN014B EN P May 2002 1769 Compact 1 0 Communication Bus Expansion Cables 5 Cable Types and Lengths Table 1 Catalog Number Cable Type Length 1769 CLL1 Left bank to left bank expansion 1 ft 305 mm 1769 CLL3 Left bank to left bank expansion 3 28 ft 1 m 1769 CRR1 Right bank to right bank expansion 1 ft 305 mm 1769 CRR3 Right bank to right bank e
8. e Sink Source Input 769 1N007 Compact 1 0 module 1769 1016 odule Installation Instructions Installation guides for 1769 Discrete Compact 1769 0B16 Solid State 24V de Source 769 1N054 Compact 1 0 module 1769 0B16 Output Module Installation Instructions Installation guides for 1769 Discrete Compact 1769 0B16P Solid State 24V de Source 769 IN052 Compact 1 0 module 1769 0B16P Output Module Installation Instructions Installation guides for 1769 Discrete Compact 1769 0A8 100 to 240V ac Solid State 769 IN055 Compact l O module 1769 0A8 Output Module Installation Instructions Installation guides for 1769 Discrete Compact 1769 0V16 Solid State 24V de Sink Output 1769 INO56 Compact 1 0 module 1769 0V16 odule Installation Instructions Installation guides for 1769 Discrete Compact 1769 IO6XOW4 24V de Sink Source Input 769 IN050 Compact I O module 1769 IO6XOW4 AC DC Relay Output Module Installation Instructions Installation guides for 1769 Discrete Compact 1769 IM12 240V ac Input Module 769 IN011 Compact 1 0 module 1769 IM12 Installation Instructions Installation guides for 1769 Analog Compact 1769 IF4 Analog Input Module Installation 1769 IN048 Compact 1 0 module 1769 IF4 Instructions Installation guides for 1769 Analog Compact 1769 0F2 Analog Output Module 769 IN049 Compact 1 0 module 1769 0F2 Installation Instructions Installation guides for 1769 Analog Compact 1769 IF4X0F2 Combination Analog Module 1769 IN057 Compact 1 0 module 1769 IF4XOF2 Installation Instru
9. pecifications Approximate Shipping 3 foot cables 350 g 0 77Ibs Weight with carton 1 foot cables 300 g 0 66 Ibs Storage Temperature 40 C to 85 C 40 F to 185 F Operating Temperature 0 C to 60 C 32 F to 140 F Operating Humidity 5 to 95 non condensing Operating Altitude 2000 meters 6561 feet Vibration Operating 10 to 500 Hz 5G 0 030 inches maximum peak to peak Relay Operation 2G Shock Operating 30G panel mounted 20G DIN rail mounted Relay Operation 7 5G panel mounted 5G DIN rail mounted Non Operating 40G panel mounted 30G DIN rail mounted Agency Certification C UL certified under CSA C22 2 No 142 UL 508 listed CE compliant for all applicable directives Hazardous Environment Class Class Division 2 Hazardous Location Groups A B C D UL 1604 C UL under CSA C22 2 No 213 Publication 1769 1N014B EN P May 2002 10 1769 Compact I O Communication Bus Expansion Cables Notes Publication 1769 1N014B EN P May 2002 1769 Compact 1 0 Communication Bus Expansion Cables 11 Notes Publication 1769 1N014B EN P May 2002 Notes www rockwellautomation com Corporate Headquarters Rockwell Automation 777 East Wisconsin Avenue Suite 1400 Milwaukee WI 53202 5302 USA Tel 1 414 212 5200 Fax 1 414 212 5201 Headquarters for Allen Bradley Products Rockwell Software Products and Global Manufacturing Solutions Americas Rockwell Automation 1201 South Se
10. xpansion 3 28 ft 1 m 1769 CRL1 Right bank to left bank expansion 1 ft 305 mm 1769 CRL3 Right bank to left bank expansion 3 28 ft 1 m 1 Approximate cable length is measured from end to end of the cable only jot 15 mm 32 mm_ i 32 mm 0 59 in spam ee 1 26 in 0 71 in 18mm q 0 71 in 1769 CLLx 1769 CRRx 1769 CRLx 118 mm 4 65 in 15 mm A 0 59 in Ly AL Ly 118 mm 4 65 in 118 mm 4 65 in Publication 1769 1N014B EN P May 2002 6 1769 Compact 1 0 Communication Bus Expansion Cables System Configurations The following illustration show examples of two valid system setups Right to Right D o e x lt Ss o olx 33 a Bank 1 LE oz gt 2 2A x L S a z yk gt a 3 sa 1 0 Slot Number 1 2 gt E 3lo o a o Bank2 5 5 15 Sie El 8 8 con lee a e z Z co ms Left to Left 1 0 Slot Number 1 4 5 gt e CE pu x E amp 2 e S Le Se w ye Bank3 la 5 lelelel z Z S a 2 1 0 Slot Number 6 7 8 9 Right to Left Bank 1 Bank 2 Bank 3 2 Ss e e al sl ls 5 5 2 S 2 gt ZS x z 2e X Q g z Q ne SS sa o D o S D gt E 55 8 S p 2 8 g gt B z 8 BP ee g RE aan 2 S 2 z Ss g 3 a ES 3 a 1 0 Slot Number 1 2 4 5 e When configuring