Home
USER MANUAL - Gulf Fiberoptics
Contents
1. B Type M 003 Rev C INSTALLATION Experienced or expert personnel are not required to install the VISUALUX LED Once the installation is complete please continue with the procedures detailed in the Inspection and Operation section MN Thoroughly follow the instructions included in this section 1 Unpack the eguipment carefully 2 Place the VISUALUX LED on a solid flat surface 3 Gonnect the fiber optic cable to the corresponding connector of the individual adapter depending on the fiber optic to be used Storz ACMI Wolf To avoid damage to the light source or the fiber optic cable the proper adapter must be selected to match the fiber optic connector 1 Once the VISUALUX LED is turned on ensure the cooling fan is functioning If the cooling fan is not operating turn the equipment off immediately to avoid failures in the LED system as a result of high temperature The VISUALUX LED shall only be used in places with electrical installations that meet the local regulations in effect It shall always be connected to the grounding of the medical room or endoscopy tower through a ground cable The VISUALUX LED shall be connected to the voltage line through the power supply cable provided The power supply shall only be provided with a protected plug and the adequate ground connection To avoid the risk of vision damage do not look directly into the light source connector port while the unit is running INSPECTION AN
2. Fiberontice Visualuxf FJ USER MANUAL LED LIGHT SOURCE MODEL GMF LS02 E Gul Fiberoptics M 003 Rev C INDEX NA CANE CE HON a a 3 COMPONENTS zazila n ln kn 4 DESCE MON set pS 4 PRONA a o qeda 4 PEF A e e E a S S 4 TECHNICAL SPECIFICATIONS izoae posun s tu i K l aa Pa H aaa 5 AB ES eas sn no 6 ICON DESCRIPTION a s O O ans 6 INSTALLATION consigan O o aa 7 INSPECTION AND OPERATION 522780 Vl ks AE 7 NOREG MON netas tt a eee eee 7 ORERATO Ness dada 8 MAINTENANCE ezren O ON O 0 Gaaone 8 A aba t a a a do k o ooo tac 8 ELECTRICAL CONNEC TIONS i skon hi e 9 FUSE REPLACEMENT ina 9 TROUBLESHOOTING incitan a on 10 WARNIN CS ts o DN a 10 MAINTENANCE CARD suscita id 12 TECHNICAL SERVI E e dn 13 WARRANTY a ai reci Vies 13 A e O o O on cata seas eee cates 13 M 003 Rev C INTRODUCTION The VISUALUX LED light source is intended for use in office based medical applications such as ENT and clinical areas It has a LED Light Emitting Diode lighting module produces cold deep and white light Its enhancement of brightness and colors makes it suitable for use in many types of procedures The purpose of this manual is to explain the function and operation of the light source Before turning the equipment on for the first time please read the entire manual and pay special attention to all the safety measures in order to prevent any damage that may occur either to the user or the patient AN This symbol s
3. ATIONS POWER SUPPLY VOLTAGE N OF PHASES FREQUENCY CLASS TYPE PROTECTION LEVEL AGAINST WATER ENTRANCE POWER CONSUMPTION FUSE COLOR TEMPERATURE LED SYSTEM SERVICE LIFE REFRIGERATION OVER TEMPERATURE PROTECTION DIMMER SERVICE CONDITIONS STORAGE AND TRANSPORTATION CONDITIONS WEIGHT DIMENSIONS width depth height M 003 Rev C 90 240 V 1 single phase 50 60 Hz B IPXO 110W T3AL250V 6000 K Approximate 50 000 Hours Approximate Forced air Automatic LED system power off Electronic 50 104 F 10 40 C 35 75 relative humidity 700 1060 HPa 22 113 F 30 45 C 10 95 relative humidity 500 1060 HPa 5 86 lbs 2 66 Kg 8 07 x 11 22 x 4 13 inches 205 x 285 x 105mm LABELS The following label is located either on the rear or the bottom of the VISUALUX LED light source It contains technical data as well as the serial number of the device Please refer to this label when ordering replacement parts or requesting service VISUALUX LED m Gulf Modical Fitre erp tic Serial No LED110RX110110006 VOLTAGE 90 240 v FREQUENCY 60 60 Hz POWER 110 VA FUSE T3AL280V MANUFACTURED FOR GULF MEDICAL FIBEROPTICS INC OLDSMAR FLORIDA U S A ICON DESCRIPTION Attention Read the related documentation Alternate current gt Protect against water a a a a Saar g Fragile CE Mark N N Manufacturer Identification Name Address
4. D OPERATION INSPECTION Once installation is complete and before the unit is powered on please perform the following check list e Verify that the electrical network has its grounding connection in perfect conditions and that it makes perfect contact with the equipment e Check that the fuse holder has a fuse installed and that it is the correct one T3AL250V e Check that the ventilation grid is completely free without obstruction e Ensure an adequate air flow area around the unit e Verify that there are no gas or liquid sources near the equipment that may damage it All connections shall be made before turning the equipment on The VISUALUX LED shall only be used in places with electrical installations that meet all local regulations in effect If a problem is detected prior to powering on the unit please contact the technical service department of your local authorized distributor M 003 Rev C OPERATION This section thoroughly describes the equipment start up and functioning verification procedure It is recommended to perform this procedure after installing the equipment and during maintenance inspections A The equipment shall only be operated by qualified personnel 1 Connect the power supply cable to the equipment and the electrical network Turn the VISUALUX LED on by pressing the general on off switch to the 1 position Ensure the cooling fan is operating Turn the LED system on by turning the light inte
5. f the problem The VISUALUX LED shall be sent in its original packaging so that it is not damaged during transportation Gulf Fiberoptics shall not be liable for damages that may occur during transportation caused by deficient packaging WARRANTY Gulf Fiberoptics states that the VISUALUX LED has complied with the required Quality Control verification and has no manufacturing defects This guarantees the appropriate functioning under adequate use in agreement with the indications of this manual The warranty period is for one 1 year as from the date of purchase invoice Gulf Fiberoptics shall not be liable for any damage caused to by the VISUALUX LED due to incorrect use negligence cleaning or incorrect storage Any repairs made by personnel not authorized by Gulf Fiberoptics will void this warranty The described warranty is exclusively valid for the original buyer The following parts are excluded from the warranty e Damages resulting from connections to inadequate power supplies If the VISUALUX LED requires service outside of the warranty period all shipment from and to Gulf Fiberoptics or its authorized technical service facilities is the sole responsibility of the client RIGHTS All the rights arising from the manual herein especially its reproduction publishing and translation are reserved No part of this manual shall be reproduced by any means photocopy microfilm or other methods without the previous written authori
6. hall be used in this manual to indicate information that includes warnings or important precautions Please read the manual thoroughly before operating the equipment Should you have any doubt regarding the contents of the manual herein or the equipment operation and safety please contact your local distributor or Gulf Fiberoptics Responsible Firm Gulf Fiberoptics Inc 448 Commerce Blvd Oldsmar Florida 34677 U S A Telephone 1 813 855 6618 Facsimile 1 813 855 6627 Web www qulffiberoptics com E Mail contact gulffiberoptics com EU Authorized Representative EC REP European Device Solutions Ltd 17 Springwell Drive Sheffiled Yorskhire S20 1XA England 44 754 559 5464 Gulf Fiberoptics VISUALUX LED light source is CE approved complying with European Council Directive 93 42 CEE related to medical equipment The MDD equipment classification is M 003 Rev C COMPONENTS The VISUALUX LED light source includes the following components It is recommended to identify and check their existence before proceeding with the installation e Main Unit e Power Supply Cable e User Manual DESCRIPTION FRONT PANEL MODEL GMF LS02 So O Or HH 1 On Off switch 2 Light Intensity Control Dimmer 3 Fiber optic cable connector REAR PANEL EOI LILA ILI s s 5 Earth connection 6 Power supply cable connector with fuse holder 7 Ventilation grid M 003 Rev C TECHNICAL SPECIFIC
7. l supply cable to the source electrical source The power supply cable Replace the power is broken or cut supply cable The plug is in bad Change the plug condition Fuse broken or burnt Replace the fuse The green pilot light Exhausted LED system Contact your distributor from the on off switch turns on but the LED Over temperature LED Clean and clear the system does not system protection lateral ventilation grids activated Check if the fan is running Turn the equipment off immediately and contact your distributor Internal fuse burnt or Contact your distributor defective board Light intensity is not Dimmer in minimum Turn the dimmer the correct one intensity clockwise to increase the light intensity Defective LED system Contact you distributor High temperature Lateral ventilation grids Clear the lateral are obstructed ventilation grids Fan is not working Turn the equipment off immediately and contact your distributor If the problem cannot be solved please contact your local authorized distributor to request technical service WARNINGS It is important to read this manual thoroughly before using the VISUALUX LED Gulf Fiberoptics shall not be liable for the damages that may occur if the equipment is not used according to these instructions and following the criteria mentioned herein below e Do not install the equipment near heating sources such as stoves e Install the equipment on a firm and horizontal su
8. nsity control dimmer clockwise OF ae M Use this control to regulate the light intensity The VISUALUX LED light source has an over temperature protection The LED module will turn off if it experiences high internal temperatures 5 When not in use turn the VISUALUX LED off in order to maximize the LED system lifetime and conserve energy MAINTENANCE In order to maintain optimum operation of the VISUALUX LED it is recommended the following procedures are performed e Periodic cleaning of all exterior components including the ventilation grid e Inspection of electrical connections e Annual technical inspection of the equipment To perform any required service contact your local authorized distributor All technical service work repair or modification should be noted on the Maintenance Card of this manual indicating work performed date name and signature of the person in charge CLEANING Before cleaning the VISUALUX LED disconnect the power supply cable form the electrical network External Surfaces Clean the external surface of the equipment using a piece of cotton or cloth moistened with mild detergent or soap Use only adequate products for the external cleaning of electrical equipments prepared in accordance with the manufacturer s indications Perform the cleaning with special care avoiding water or humidity access to the equipment Do not use flammable products especially alcohol when the VISUALUX LED is ho
9. pment be sold or donated the manual shall go with it If as a consequence of e Incorrect use of the equipment e Under utilization of this manual e Poor care and maintenance of the equipment or e Repair and manipulation by unauthorized personnel any material or personal damage caused to third parties Gulf Fiberoptics and the distributor of the equipment shall not assume any responsibility for such damages 11 M 003 Rev C MAINTENANCE CARD Work Performed Responsible Person This card shall only be completed by the authorized person from the company responsible for the maintenance repair and modification of the device Frequent and timely updates to this service table are recommended 12 M 003 Rev C TECHNICAL SERVICE VISUALUX LED light sources shall be exclusively repaired and or maintained in authorized Gulf Fiberoptics technical facilities Gulf Fiberoptics recommends using the following procedures to speed up the repair service and replacement of the guaranteed products 1 Contact the technical service department of your local distributor or Gulf Fiberoptics 2 Give detailed information of the problem 3 If the problem cannot be solved by troubleshooting the product must be shipped to your local authorized distributor for service The following product information shall be attached Owner s name Owner s address e Contact name and phone number Produc s serial number Description o
10. rface in a well ventilated area e Avoid exposing the equipment and fittings directly to sunlight dust humidity vibrations or excessive impacts e Do not use around inflammable anesthetic mixed with air oxygen or nitrous oxide 10 M 003 Rev C e Do not use volatile substances benzine thinner or solvents in general to clean the equipment since it may cause damage It is recommended to use a soft wet cloth soaked in neutral soap or any specific product to clean electronic equipment cases e Do not introduce objects in the holes or rest any containers with liquid on the equipment e Prevent the power supply cable from being walked rolled over or placed under any piece of furniture e Do not use the equipment when there are electrical storms e Always unplug the equipment when it is not being used e The VISUALUX LED is grounded through a conductor of the power supply cable This essential grounding is provided for a safe operation of the equipment e Incase of interference with other electro medical or electrical equipment widen the distance between the VISUALUX LED and the other device in order to minimize these effects e Do not open the equipment Maintenance and repairs shall be made by Gulf Fiberoptics Gulf Fiberoptics shall not be liable for the consequences of maintenance or repairs made by unauthorized personnel e This manual of instructions shall be kept together with the equipment for future consultations Should the equi
11. t Do not turn the light source on until one hour 1 has passed from the cleaning to eleminate the chance for damage M 003 Rev C It is recommended to clean the exterior surface of the device every 15 days ELECTRICAL CONNECTIONS Constantly check the condition of all components and their aging process Verify there are no Faulty broken or cut cables Faulty connection between the cable and the plug Oxide corrosion in connection pins FUSE REPLACEMENT 1 Disconnect the power supply cable from the electrical network and the equipment 2 Under the power supply cable connector there is a small rectangular plastic holder where the fuses are located Using a screwdriver and with a slight pressure remove the lid to replace the damaged fuse 3 Remove the fuse and replace it with a new fuse T3AL250V located inside the same plastic holder Obtain a spare fuse to minimize potential out of service time 1 To avoid shock injury or damage to the VISUALUX LED use ONLY fuses with the same specified ratings T3AL250V 4 Place the fuse lid back pushing it until a click is heard 5 Connect the power supply cable M 003 Rev C TROUBLESHOOTING The following table indicates the most common problems and their quick solutions Please consult this table for any difficulty you may encounter PROBLEM PROBABLE CAUSE ACTION The equipment does It is not connected to Connect the power not turn on an active electrica
12. zation by Gulf Fiberoptics No part of this manual shall be reproduced multiplied or published through electronic data processing The information contained in this manual can be modified without previous notification without it representing any liability for Gulf Fiberoptics Gulf Fiberoptics Inc 448 Commerce Blvd Oldsmar FL 34677 U S A 13 M 003 Rev C NOTES M 003 Rev C 14
Download Pdf Manuals