1. FL 1000 XT    LED light generators    for use with fibre optic lighting    User manual       Mounting and installation instructions    Item no   0123 0050  0123 0053  0123 2050  0123 2053  0123 0040  0123 2040     99082088 30 09 2013    FL 1000 XT B 3000 K   FL 1000 XT B 3000 R CRI 90    FL 1000 XT B US 3000 K   FL 1000 XT B US 3000 K CRI 90   FL 1000 XT B 4000 K   FL 1000 XT B US 4000 K    Roblon    Contents       Introduction     Product overview     Technical data     Installation     Dimming US models only     Mounting     Installing in closed compartments    Installing adjacent light generators    Mounting filters     Spare parts     Accessories     Troubleshooting    CON DOOR WN        i GEN  N AR O Oo    1 Introduction     Roblon FL 1000 XT light generators are designed for use    outdoors    with glass or PMMA fibre    in all installation set ups  including in closed compartments    Follow the installation instructions correctly in order to ensure    safe operation    enhanced functionality    extended lifetime for components    uninterrupted illumination    2 Product overview     FL 1000 XT light generator    28  gt   9 harness adaptor  Two Allen keys   Screws   Wall plugs   Power cord   User manual       FL 1000 XT B    FL 1000 XT B US    3 Technical data     Light port   Fibre type   Total power consumption  amp  700 mA  Light source power   Supply voltage   Supply voltage US   Applied LED    Light source lifetime  CCT  nominal   CRIg  Ra  typical value    Protecti
2. cool for 15 minutes   Try again     Is the harness common end dirty    Clean filter with damp cloth   Dry with lint free cloth       Ambient temperature  max  45    Measured 50 mm from light generator   Surface temperature max  73    Measured beside the screw when it has been running for min  1 hour        Measure ambient temperature here  Measure surface temperature beside the screw       Roblon accepts no responsibility for possible errors in printed and electronic material  Roblon reserves the right to alter or discontinue products  without notice     2012  Roblon A S     Roblon    Roblon Lighting Tel   45 9620 3300  Nordhavnsvej 1 Fax   45 9620 3399  9900 Frederikshavn info roblon com  Denmark www roblon com    
3. insert the assembled inner part in the casing    10   11   12     Replace the O ring   Insert the casing screws and tighten   Replace the baseplate and screw in place        10    10 Spare parts     Model designation Description    LED  FL 1000 XT LED module    LED  FL 1000 XT  US LED module US models    Philips 25W CC 220 240 V    Philips 35W CC 120 277 V Driver US models    0129 4004    0129 4005  0129 3000    0129 3001       11 Accessories     CTC Filter A  500K  CTC Filter A  900K  CTC Filter A  1200K  Colour Filter A yellow  Colour Filter A green  Colour Filter A blue    Colour Filter A red Red filter 0126 1007  Bracket that can be  Mounting bracket padlocked 0126 7000          11    12 Troubleshooting     Trace the problem    No light          Is the power on  Turn the power on     Is the power cord connected Connect the power cord properly   properly     Is the light generator too hot    Check it is installed according to  the instructions    Switch generator off    Let it cool for 15 minutes    Try again   pis the LED working   d ReplacetheleD   gt   Light switches on and off  Is the light generator too hot    Check it is installed according to   the instructions    Switch generator off    Let it cool for 15 minutes    Try again     Light output has Has the light been dimmed via a Increase brightness using dimmer  diminished dimmer switch  switch     Is the light generator too hot    Check it is installed according to  the instructions   Switch generator off   Let it 
4. on rating  Driver type  Driver lifetime  Dimmable    Thermal protection  Cooling system   Noise level   Ambient temperature  Material   Dimensions  L x H x W   Weight   Safety      Y or   28 mm   PMMA   Glass   24 W   19 3 W   220 240 V   50 60 Hz   120 277 V   50 60 Hz   LUXEON S1000 LXS8 PW30  3 000 K   LUXEON S1000 LXS8 PW40  4 000 K   50 000 hours   3 000 K   85    IP65   Integrated electronic  50 000 hours  Trailing edge   1 10V  US models   Automatic decrease  Natural convection  N a    20  C to 45  C  Aluminium   POM  298 x 193 x 95 mm  2 3 kg   CE    4 Installation     1     Use the Allen key to loosen and remove the   28  gt   9 harness adaptor that  is mounted in the light port       For use with   28 harness     The generator is now ready for installation   For use with   9 harness   Place the   28  gt   9 harness adaptor on the harness common end       Remove the plastic plug on the baseplate  directly below the light port     Insert the common end fully in the light port      Tighten the screw on the base with an Allen key      Insert the plastic plug       Ensure all installation and ventilation requirements are met       Connect the power cord to the mains        5 Dimming of 01232050     1  Ensure the dimmer is compliant with 1 10V US models    See   Dimmer selection  guide for FL 1000 models on www  roblonlighting com     2  Remove the plastic plug    3  Screw in the cable gland    4  Guide the dimmer cable through the cable gland     gt   Use a cable tie to 
5. secure the cable s position     2 3 4       6 Mounting   6a Surface mounting   1  Attach to surface using two screws in the baseplate holes     2  Vertical installation  to maintain IP 65 protection  mount with the light port  facing down     170 mm  bet  26 mm TP  gt        gt  9  holes  ay   p    6a Bracket mounting     1  Attach the bracket  not supplied  see Accessories  to the surface using two  SCrevys     2  Mount the light generator on the bracket     Q  140 mm w  between O    6 mm DR     holes       7 Installing in closed compartments     Requirements    Enough space to allow natural heat transmission through surfaces   Surfaces should not be insulated    Air volume per light generator minimum 0 03 m      Ventilation holes per light generator with min  20 cm  air inlet and min   20 cm  air outlet    Max  ambient temperature 45  C        8 Installing one or more light generators     Requirement  min  100 mm distance between adjacent light generators in  order to ensure sufficient heat transmission     100    P        9 Mounting filters   Colour filters  not supplied   CTC filters  not supplied     CO NO In ES  tu N       SO      Unscrew and remove the baseplate      Remove the casing screws      Remove the O ring      Carefully detach and manoeuvre the assembled inner part out of the casing     Unscrew the plastic front part      Assemble the filter and bracket      Mount the assembled filter in the detached front part      Screw the front part back on      Carefully 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Frigidaire GLEB30S8A Electric Single Oven  UTV-1100 Multi Gauge for 2007 Yamaha Rhino  Betriebsanleitung IPC1419  Betriebsanleitung Controlbox  Acctiva professional [42,0410,0551]  PRIMERGY BX600 スイッチブレード(1Gbps)(PG  Escort ZR3 Radar Detector User Manual  Samsung SPF-72V Manuel de l'utilisateur  Télécharger l`édition n°246 au format PDF    Copyright © All rights reserved. 