Home

SCS 300 Sync Converter/Stabilizer User`s Manual

image

Contents

1. C Ji X c LN LE H BEE Table of Contents Chapter One Introduction eee 1 1
2. Both front false faceplates use 2 screws Ge 7 2 4 40 x 3 16 Screws 0000 Use 2 mounting holes on opposite corners Figure 2 1 Mounting the SCS 300 on a standard 9 5 deep rack shelf 6 Deep Rack Shelf 1 2 Rack Width False Fro Face Plate 1 4 Rack Width False Front Face Plate nt Use 2 mounting holes on opposite corners Figure 2 2 Mounting the SCS 300 on a 1U 6 deep rack shelf 4 If the shelf is not already mounted in the rack use the supplied hardware to mount it following the instructions that came with the shelf 5 When mounted continue the installation by connecting the input output and power cables SCS 300 Installation Connection and Settings 2 3 Installation Connection and Settings cont d Mounting the SCS 300 under a desk To mount the SCS 300 under a desk or in a podium using the under desk mounting kit Extron part 70 077 01 MBU 125 do the following 1 Attach the mounting brackets to the SCS 300 using the four machine screws supplied with the mounting kit as shown in figure 2 3 Figure 2 3 Attaching the under desk brackets 2 Holding the device up against the underside of the surface to which you are mounting it mark the four screw holes 3 Drill four pilot holes each 3 32 2 mm in diameter by 1 4 6 4 mm deep where marked on the template 4 Using the four supplied wood screws attach the brackets under the
3. lectrocution Attention Lire les instructions Prendre connaissance de toutes les consignes de s curit et d exploitation avant d utiliser le mat riel Conserver les instructionse Ranger les consignes de s curit afin de pouvoir les consulter l avenir Respecter les avertissements Observer tous les avertissements et consignes marqu s sur le mat riel ou pr sent s dans la documentation utilisateur Eviter les pi ces de fixation e Ne pas utiliser de pi ces de fixation ni d outils non recommand s par le fabricant du mat riel car cela risquerait de poser certains dangers Sicherheitsanleitungen Deutsch Dieses Symbol soll dem Benutzer in der im Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise zur Bedienung und Wartung Instandhaltung geben DiesesSymbolsollden Benutzerdarauf aufmerksam machen daf im Inneren des Geh uses dieses Produktes gef hrliche Spannungen dienichtisoliert sind und die einen elektrischen Schock verursachen k nnen herrschen Achtung Lesen der Anleitungen Bevor Sie das Ger t zum ersten Mal verwenden sollten Sie alle Sicherheits und Bedienungsanleitungen genau durchlesen und verstehen Aufbewahren der Anleitungen Die Hinweise zur elektrischen Sicherheit des Produktes sollten Sie aufbewahren damit Sie im Bedarfsfall darauf zur ckgreifen k nnen Befolgen der Warnhinweise Befolgen Sie alle Warnhinweise und Anleitungen auf dem Ger t oder in der Benutzerdokum
4. overwritten to memory location 1 All saved settings are retained in the memory after power down SCS 300 e Installation Connection and Settings 2 9 Installation Connection and Settings cont d Front Panel DIP Switch Settings The bank of eight DIP switches allows the user to control sync input termination sync polarity output sync format and serration pulses or to disable all sync processing Switches furthest to the right takes the highest priority Set each switch as desired in the order they are listed 2g o gt OD oO gt Oo Lu E gt c o o zu COMP SYNC OUT SERR REMOVAL NO SYNC PROC RsGsBs OUT Up position On Down Off Default all Off Settings for the DIP switches on the SCS 300 Switch 1 On 10k ohm sync input termination Off 510 ohm sync input termination Switch 2 On Force negative sync polarity on output Off Sync polarity follows input Switch 3 On Enable composite sync output Off Disable composite sync output Switch 4 On Sync on green output Off Disable sync on green output Switch 5 On Enable RsGsBs sync on all Off Disable RsGsBs Ne When switch fts 3 4 and 5 are in the off position Horizontal and Vertical sync is on Switch 6 On Disable remove serration pulses Off Enable pass serration pulses Switch 7 On Disables sync processing Off Normal sync processing If switch 7 is in the on position it disables all switch
5. mounting surface see figure 2 3 5 When the SCS 300 is mounted continue the installation by connecting the input output and power cables 2 4 SCS 300 Installation Connection and Settings Mounting the SCS 300 through a desk To mount the SCS 300 through a desk or table using the through desk mounting kit Extron part 70 077 02 MBD 129 do the following 1 Attach the mounting brackets to the SCS 300 using four machine screws and washers supplied with the mounting kit as shown in figure 2 4 Figure 2 4 Attaching the through desk brackets 2 Holding the device up against the underside of the surface to which you are mounting mark the four screw holes 3 Drill four pilot holes each 3 32 2 mm in diameter by 1 4 6 4 mm deep where marked on the template 4 Using the four supplied wood screws attach the brackets to the mounting surface see figure 2 4 5 When the SCS 300 is mounted continue the installation by connecting the input output and power cables SCS 300 Installation Connection and Settings 2 5 Installation Connection and Settings cont d 2 6 Mounting the SCS 300 to a projector pole To mount the SCS 300 to a projector pole use one of the optional accessory Projector Mounting Kits PMK series To install the Extron PMK follow the instructions supplied with the kit To attach the SCS 300 to the PMK use the two supplied 4 40 x 3 16 screws in the opposite diagonal corne
6. t sollte nur ber die auf dem Produkt angegebene Stromquelle betrieben werden Dieses Ger t wurde f r eine Verwendung mit einer Hauptstromleitung mit einem geerdeten neutralen Leiter konzipiert Der dritte Kontakt ist f r einen Erdanschluf und stellt eine Sicherheitsfunktion dar Diese sollte nicht umgangen oder aufer Betrieb gesetzt werden Stromunterbrechung Um das Ger t auf sichere Weise vom Netz zu trennen sollten Sie alle Netzkabel aus der R ckseite des Ger tes aus der externen Stomversorgung falls dies m glich ist oder aus der Wandsteckdose ziehen Schutz des Netzkabels e Netzkabel sollten stets so verlegt werden daf sie nicht im Weg liegen und niemand darauf treten kann oder Objekte darauf oder unmittelbar dagegengestellt werden k nnen Wartung e Alle Wartungsmafsnahmen sollten nur von qualifiziertem Servicepersonal durchgef hrt werden Die internen Komponenten des Ger tes sind wartungsfrei Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem Fall dieses Ger t selbst ffnen da beim Entfernen der Abdeckungen die Gefahr eines elektrischen Schlags und oder andere Gefahren bestehen Schlitze und ffnungen e Wenn das Ger t Schlitze oder L cher im Geh use aufweist dienen diese zur Vermeidung einer Uberhitzung der empfindlichen Teile im Inneren Diese Offnungen d rfen niemals von anderen Objekten blockiert werden Litium Batterie Explosionsgefahr falls die Batterie nicht richtig ersetzt wird Erse
7. About this Manual 1 2 About the SCS 300 1 2 POS a a a 1 2 Chapter Two Installation Connection and Settings OOO 2 1 Mounting the SCS 300 Li 2 2 UL requirements for rack mounted devices 2 2 Mounting the SCS 300 on a rack shelf 2 2 Mounting the SCS 300 under a desk 2 4 Mounting the SCS 300 through a desk 2 5 Mounting the SCS 300 to a projector pole 2 6 Device Connecton 2 6 Rear Panel Features and Connection 2 7 Front Panel Features and Settings 2 9 Auto Memory for H shift Control Settings 2 9 Front Panel DIP Switch Settings 2 10 Appendix A e Reference Material A 1 Specifications ee A 2 Included Parts een ene er ee A 4 Optional Accessories A 4 AII trademarks mentioned in this manual are the properties of their respective owners 68 1251 01 Rev B 03 07 SCS 300 Table of Contents i Table of Contents cont d This page was deliberately left blank ii SCS 300 e Table of Contents SCS 300 Sync Converter Stabilizer E e 3 Q a N d 10 Chapter One Introduction About this Manual About the SCS 300 Features Introduction About this
8. Extron Electronics INTERFACING SWITCHING AND DISTRIBUTION User s Manual xt H SHIFT OUTPUT S SCS 300 SYNC CONVERTER STABILIZER WITH ADSP SCS 300 Sync Converter Stabilizer 68 1251 01 Rev B 03 07 c Se AN 3 amp d A D Se UTI ov Precautions Safety Instructions English Thissymbolisintended toalertthe user of important operating and maintenance servicing instructions in the literature provided with the equipment This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product s enclosure that may present a risk of electric shock Caution Read Instructions Read and understand all safety and operating instructions before using the equipment Retain Instructions The safety instructions should be kept for future reference Follow Warnings Follow all warnings and instructions marked on the equipment or in the user information Avoid Attachments Do not use tools or attachments that are not recommended by the equipment manufacturer because they may be hazardous Consignes de S curit Francais Ce symbole sert avertir l utilisateur que la documentation fournie avecle mat riel contient des instructions importantes concernant l exploitation et la maintenance r paration Ce symbole sert avertir l utilisateur de la pr sence dansle boitier del appareil de tensions dangereuses non isol es posant des risques d
9. ICES LE 30 000 hours MARRAINE DEP E N 3 years parts and labor Nez All nominal levels are at 10 deu Specifications are subject to change without notice SCS 300 Reference Material A 3 Reference Material cont d Included Parts Included parts Replacement part number SCS 300 60 811 01 Rubber feet 4 12 VDC Desktop power supply 1 IEC cord 1 2 pole captive screw plug orange 1 10 762 01LF Tweeker small screwdriver SCS 300 User s manual Optional Accessories These items can be ordered separately PMK 350 black white 70 563 02 03 PMK 250 black white 70 526 02 03 PMK 200 70 077 04 RSU 129 9 5 deep Universal rack shelf 60 190 01 RSB 129 9 5 deep Basic rack shelf 60 604 01 RSU 126 6 deep Universal rack shelf 60 190 10 RSB 126 6 deep Basic rack shelf 60 604 10 MBU 125 Under desk mounting kit 70 077 01 MBD 129 Through desk mounting kit 70 077 02 BNC cables 26 260 xx SY VGA cables 26 53 xx VGA cables 26 238 xx A 4 SCS 300 e Reference Material This page was deliberately left blank SCS 300 e Reference Material A 5 FCC Class A Notice Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequen
10. Manual This manual documents the features installation operation and specifications of the Extron SCS 300 Sync Converter Stabilizer About the SCS 300 The SCS 300 Sync Converter Stabilizer is a 1U high quarter rack width 6 deep sync converter and stabilizer with Advanced Digital Sync Processing ADSP The SCS 300 accepts RGBHV RGBS RGsB or RsGsBs signal inputs automatically strips off the sync on green or the sync on red green and blue and outputs RGBHV RGBS or RGsB through five BNC connectors on the rear panel An identical and simultaneous output is provided via a 15 pin HD VGA connector on the front panel The output sync is restored to the original timing using the Extron ADSP technology Horizontal shift adjustments are made from the front panel A bank of eight DIP switches allows the user to set various sync output formats set sync input impedance and control the removal of serration pulses Features Inputs Female BNCs for RGBHV RGBS RGsB or RsGsBs inputs Simultaneous output Female 15 pin HD and female BNCs for RGBHV RGBS RGsB or RsGsBs outputs Signal conversion With all DIP switches down any input signal type RGBS RGsB or RsGsBs is converted to RGBHYV output Flexibility DIP switches allow sync control for various sync output formats input impedance termination and the passing or removal of serration pulses Output sync restoration Using ADSP the output sync can
11. be restored to the original timing Furniture and wall mountability The SCS 300 can be mounted onto or in furniture or to a projector pole using a suitable Extron mounting kit see Appendix A Reference Material for a list SCS 300 Introduction s e S 3 s d 3 4 SCS 300 Sync Converter Stabilizer euro Chapter Two Installation Connection and Settings Mounting the SCS 300 Rear Panel Features and Connection Front Panel Features and Settings Auto Memory for H shift Control Settings Front Panel DIP Switch Settings Installation Connection and Settings Mounting the SCS 300 The SCS 300 can be mounted on a 1U rack shelf under or through a desk or attached to the projector pole 2 2 UL requirements for rack mounted devices The following Underwriters Laboratories UL requirements pertain to the safe installation of the SCS 300 in a rack 1 Elevated operating ambient temperature If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient temperature Therefore install the SCS in an environment compatible with the maximum ambient temperature Tma 122 F 50 C specified by Extron Reduced air flow Install the equipment in a rack so that the amount of air flow required for safe operation of the equipment is not compromised Mechanical loading Mount the equipment in the rac
12. cy energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Note This unit was tested with shielded cables on the peripheral devices Shielded cables must be used with the unit to ensure compliance Extron s Warranty Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase In the event of malfunction during the warranty period attributable directly to faulty workmanship and or materials Extron Electronics will at its option repair or replace said products or components to whatever extent it shall deem necessary to restore said product to proper operating condition provided that it is returned within the warranty period with proof of purchase and description of malfunction to USA Canada South America Europe Africa and the Middle East and Central America Extron Electronics Europe Extron Electronics Beeldschermweg 6C 1001 East Ball Road 3821 AH Amersfoort Anaheim CA 92805 USA The Netherlands Asia Japan Extron Electronics Asia Extron Electronics Japan 135 Joo Seng Road 04 01 Kyodo Building PM Industrial Bldg 16 Ichibancho Singapore 368363 Chiyoda ku Tokyo 102 0082 Japan Thi
13. entation Keine Zusatzger te e Verwenden Sie keine Werkzeuge oder Zusatzger te die nicht ausdr cklich vom Hersteller empfohlen wurden da diese eine Gefahrenquelle darstellen k nnen Instrucciones de seguridad e Espa ol Este s mbolo se utiliza para advertir al usuario sobre instrucciones importantes de operaci n y mantenimiento o cambio de partes que se desean destacar en el contenido de la documentaci n suministrada con los equipos Este s mbolo se utiliza para advertir al usuario sobre la presencia de elementos con voltaje peligroso sin protecci n aislante que puedan encontrarse dentro de la caja o alojamiento del producto y que puedan representar riesgo de electrocuci n Precaucion Leer las instrucciones Leer y analizar todas las instrucciones de operaci n y seguridad antes de usar el equipo Conservar las instrucciones e Conservar las instrucciones de seguridad para futura consulta Obedecer las advertencias Todas las advertencias e instrucciones marcadas en el equipo o en la documentaci n del usuario deben ser obedecidas Evitar el uso de accesorios No usar herramientas o accesorios que no sean especificamente recomendados por el fabricante ya que podrian implicar riesgos Warning Power sources This equipment should be operated only from the power source indicated on the product This equipment is intended to be used with a main power system with a grounded neutral conductor The third ground
14. es except for switch 1 and deactivates all sync processing and timing changes However sync edges will still be reshaped Switch 8 Spare 2 10 SCS 300 Installation Connection and Settings SCS 300 Sync Converter Stabilizer D s 4 AN 3 Ki 9 a bo Appendix A Reference Material Specifications Included Parts Optional Accessories Reference Material Specifications Video Ca E T Unity Bandwidth 2 2 300 MHz 3 dB Video input Number signal pe 1 analog RGBHV RGBS RGsB RsGsBs Ne Not compatible with interlaced signals EE Sn raid 5 BNC female Nonnnallevelsss 2 0 7 Vp p for RGB Minimum maximum levels Analog 0 3 V to 1 5 Vp p with no offset are E 75 ohms Horizontal frequency 24 kHz to 130 kHz Verheal E E me 40 Hz to 120 Hz Nominal maximum return loss lt 30 dB 5 MHz Maximum allowed DC offset 4 0 V Ta AC Video output Number signal pes 2 analog RGBHV RGBS RGsB RsGsBs Connectors ee 5 BNC female and 1 15 pin HD female Nominal level mr 0 7 Vp p for RGB Minimum maximum levels 0 3 V to 1 5 VP P with no offset follows input sche TANCE se 75 ohms Nominal maximum return loss 30 dB 5 MHz IIe 5 mV maximum with no input signal and at 0 offset Sync IDDHL e RGBHV RGBS RGsB RsGsBs Output ly PE me RGBHV RGBS RGsB RsGsBs switch selectable bert I tre te ene ere Sync on R G B RGsB RsGsBs 0 15 to 0 6 Vp p TTL 2 0 V to 5 5 Vp p with 0 2 VDC
15. ing pin is a safety feature do not attempt to bypass or disable it Power disconnection To remove power from the equipment safely remove all power cords from the rear of the equipment or the desktop power module if detachable or from the power source receptacle wall plug Power cord protection Power cords should be routed so that they are not likely to be stepped on or pinched by items placed upon or against them Servicing Refer all servicing to qualified service personnel There are no user serviceable parts inside To prevent the risk of shock do not attempt to service this equipment yourself because opening or removing covers may expose you to dangerous voltage or other hazards Slots and openings If the equipment has slots or holes in the enclosure these are provided to prevent overheating of sensitive components inside These openings must never be blocked by other objects Lithium battery There is a danger of explosion if battery is incorrectly replaced Replace it only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Avertissement Alimentationse Ne faire fonctionner ce mat riel qu avec la source d alimentation indiqu e sur l appareil Ce mat riel doit tre utilis avec une alimentation principale comportant un fil de terre neutre Le troisi me contact de mise la terre constitue un dispositif de s curit n e
16. k so that a hazardous condition is not achieved due to uneven mechanical loading Circuit overloading Connect the equipment to the supply circuit and consider the effect that circuit overloading might have on overcurrent protection and supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Reliable earthing grounding Maintain reliable grounding of rack mounted equipment Pay particular attention to supply connections other than direct connections to the branch circuit e g use of power strips Mounting the SCS 300 on a rack shelf For optional rack mounting mount the SCS 300 on a standard 9 5 deep Universal or Basic rack shelf Extron part 60 190 01 RSU 129 or 60 604 01 RSB 129 figure 2 1 or on a 6 deep Universal or Basic rack shelf Extron part 60 190 10 RSU 126 or 60 604 10 RSB 126 figure 2 2 On the standard 9 5 deep rack shelf the SCS 300 can be mounted in one of four locations at the rear of the rack or the front of the rack shelf 1 2 If the SCS 300 has feet installed remove them Align the SCS 300 over the shelf so that the two threaded holes in the base line up with two holes in the shelf Use two 4 40 x 3 16 screws to mount the SCS 300 to the shelf SCS 300 e Installation Connection and Settings 9 5 Deep Universal Rack Shelf 1 2 Rack Width Front False Faceplate Mises 1 4 Rack Width Front False Faceplate
17. ker or other small screwdriver and observe the left right movement of the image on the screen Stop when the image is centered See below for details of auto memory for H shift control settings 3 8 bank DIP switch The settings of these DIP switches control various sync adjustments For details see Front Panel DIP Switch Settings in a this chapter a 15 pin HD female connector The converted video signal is output on this connector Connect a VGA cable to the connector and to a VGA display device for simultaneous video signal output Menzl The output on the 15 pin HD connector is simultaneous and identical to the output on the five BNC connectors on the rear panel NO SYNC PROC gt ET INPUT SYNC 10KQ w ET FORCE NEG SYNC UCI COMP SYNC OUT IC socour LCI SERRREMOVAL SET fC spare LT RsGsBs OUT OFF Auto Memory for H shift Control Settings The SCS 300 has a non volatile internal memory where H shift settings are automatically saved one setting for each of up to 15 different input rates The unit automatically detects any new rate changes based on the horizontal and vertical frequencies and then saves the H shift position setting for that specific resolution Once all memory locations are full the unit overwrites the locations in sequential order beginning at number one If for example a sixteenth input rate is detected that rate s setting is saved
18. nput is sync on green RGsB RsGsBs 3 Output connectors The converted video signal output is carried on these five female BNC connectors labelled Output Use BNC cables to attach the output connectors to a projector or other display device This output is simultaneous and identical to the output on the 15 pin HD connector on the front panel RGsB When the DIP switch SOG Out is set to On and terminated 75 ohms coax cables are connected to red green and blue channels only the output is sync on green RsGsBs When the DIP switch RsGsBs Out is set to On and terminated 75 ohms coax cables are connected to red green and blue channels only the output is sync on all RGBS When the DIP switch Comp sync out is set to On and the H HV cable is connected the output is composite sync RGBHV When DIP switches 3 4 and 5 are set to Off and all cables are connected the sync output is separate horizontal and vertical H HV V AX 2 8 SCS 300 e Installation Connection and Settings Front Panel Features and Settings The front panel has four features OFF Extron SCS 300 SYNC CONVERTER STABILIZER WITH ADSP Figure 2 9 Front Panel features xt Power LED This green LED is lit when the device has power Horizontal shift control This recessed rotary dial H SHIFT adjusts the horizontal shift To adjust the horizontal D shift turn the dial using a Twee
19. offset max Sync on R G B RGsB RsGsBs 0 3 Vp p TTL 5 0 Vp p unterminated Input impedance seno toties etin 510 ohms or 10k ohms selectable Output impedance ss 75 ohms A 2 SCS 300 Reference Material Max propagation delay 48 nS Max rise fall time 3 5 nS Polarity KODEIN apies For RGBHV input output is positive or negative follows input or is forced negative switch selectable RGBS RGsB RsGsBs Negative General 02 0 re ee 100 VAC to 240 VAC 50 60 Hz external auto switchable to 12 VDC 1 A regulated Power input requirement 12 VDC 0 4 A Temperature humidity Storage 40 to 158 F 40 to 70 C 10 to 90 non condensing Operating 32 to 122 F 0 to 50 C 10 to 90 non condensing FRR Yes with optional 9 5 deep rack shelf part 60 190 10 or 60 604 01 or 6 deep rack shelf part 60 190 10 or 60 604 10 Also furniture mountable with optional kit 70 077 01 or 70 077 02 or projector mountable with kits 70 563 02 03 70 526 02 03 or 70 077 04 Ee E ype ove Metal Enclosure dimensions 1 7 H x 4 3 W x 6 D LU high rack wide 4 2 cm H x 10 9 cm W x 15 2 cm D Depth excludes connectors Product weight pe 0 8 Ibs 0 4 kg DIP PINS E ni 2 lbs 1 kg Klee E ISTA 1A in carton International Safe Transit Association Listes Motto estE UL CUL CO CE FCC Class A VCCI AS NZS
20. rs of the device base to secure it to the bracket as shown in figure 2 5 Extron SCS 300 Sync Converter Stabilizer Extron PMK 300 Multi product Projector Mount Kit Figure 2 5 Mounting the unit to a projector pole Device connection Upon completion of the mounting method chosen the SCS 300 sync converter stabilizer should be connected to a suitable video signal source and to a projector or other display device for output Figure 2 6 shows an example of an application Cable connections are made via the rear panel Extron p CrossPoint 450 Plus Series Matrix Switcher Sync Converter Stabilizer LS ZZ Projector Figure 2 6 Typical SCS 300 application SCS 300 e Installation Connection and Settings Rear Panel Features and Connection The rear panel has three main features Figure 2 7 Rear Panel features Power connection point This dedicated female 12V 3 5mm 2 pole captive screw connector enables connection of the 12 VDC external power supply Wire the power supply cord into the supplied male orange connector as shown in figure 2 8 CAUTION Power supply voltage polarity is critical Incorrect voltage polarity can damage the power supply and the SCS 300 Identify the power cord negative lead by the ridges on the side of the cord figure 2 8 The length of the exposed stripped copper wires is important The ideal length is 5 16 7 mm Longer bare wires can shor
21. s Limited Warranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnormal operating conditions or non Extron authorized modification to the product If it has been determined that the product is defective please call Extron and ask for an Applications Engineer at 714 491 1500 USA 31 33 453 4040 Europe 65 6383 4400 Asia or 81 3 3511 7655 Japan to receive an RA Return Authorization number This will begin the repair process as quickly as possible Units must be returned insured with shipping charges prepaid If not insured you assume the risk of loss or damage during shipment Returned units must include the serial number and a description of the problem as well as the name of the person to contact in case there are any questions Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality performance merchantability or fitness for any particular use In no event will Extron Electronics be liable for direct indirect or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage Please note that laws vary from state to state and country to country and that some provisions of this warranty may not apply to you As Extron Electronics USA Extron Electronics Europe Extron Electronics Asia Extron Electronics Japan A s 9 1230 South Le
22. ssayez pas de la contourner ni de la d sactiver D connexion de l alimentation Pour mettre le mat riel hors tension sans danger d connectez tous les cordons d alimentation de l arri re de l appareil ou du module d alimentation de bureau s il est amovible ou encore de la prise secteur Protection du cordon d alimentation Acheminer les cordons d alimentation de mani re ce que personne ne risque de marcher dessus et ce qu ils ne soient pas cras s ou pinc s par des objets R paration maintenance Faire ex cuter toutes les interventions de r paration maintenance par un technicien qualifi Aucun des l ments internes ne peut tre r par par l utilisateur Afin d viter tout danger d lectrocution l utilisateur ne doit pas essayer de proc der lui m me ces op rations car l ouverture ou le retrait des couvercles risquent de l exposer de hautes tensions et autres dangers Fentes et orifices Si le bo tier de l appareil comporte des fentes ou des orifices ceux ci servent emp cher les composants internes sensibles de surchauffer Ces ouvertures ne doivent jamais tre bloqu es par des objets Lithium Batterie Il a danger d explosion s ll y a remplacment incorrect de la batterie Remplacer uniquement avec une batterie du meme type ou d un ype equivalent recommande par le constructeur Mettre au reut les batteries usagees conformement aux instructions du fabricant Vorsicht Stromquellen e Dieses Ger
23. t together Shorter wires are not as secure in the captive screw connectors and could be pulled out Do not tin the stripped power supply leads before installing the captive screw connector Tinned wires are not as secure in the captive screw connector and could be pulled out Use the supplied tie warp to strap the wires to the connector POWER 12V 0 4A MAX Smooth Ridges ae ge A e e Orange Captive 1 A crew Connector c 3 Power Supply SECTION A A Output Cord Tie Wrap 7 mm MAX Figure 2 8 Wiring the power connector SCS 300 e Installation Connection and Settings 2 7 Installation Connection and Settings cont d Insert the wired connector into the female 2 pole captive screw connector marked power CAUTION When using a compatible power source from the projector verify that it is 12 VDC positive Input connectors Non interlaced video signal input is made on these five female BNC connectors labeled Input Connect the input devices video signal cables to the BNC connectors ensuring the correct cable matches the labeled input connector RGBHV If all cables are connected the sync input is separate horizontal and vertical PEN O O O Q RGBHV RGBS If the H HV composite sync cable is connected the input is composite sync RGsB RsGsBs If coax cables are connected and terminated 75 ohms to the red green and blue channels only the i
24. tzen Sie verbrauchte Batterien nur durch den gleichen oder einen vergleichbaren Batterietyp der auch vom Hersteller empfohlen wird Entsorgen Sie verbrauchte Batterien bitte gem t den Herstelleranweisungen Advertencia Alimentaci n el ctrica e Este equipo debe conectarse nicamente a la fuente tipo de alimentaci n el ctrica indicada en el mismo La alimentaci n el ctrica de este equipo debe provenir de un sistema de distribuci n general con conductor neutro a tierra La tercera pata puesta a tierra es una medida de seguridad no puentearia ni eliminaria Desconexi n de alimentaci n el ctrica e Para desconectar con seguridad la acometida de alimentaci n el ctrica al equipo desenchufar todos los cables de alimentaci n en el panel trasero del equipo o desenchufar el m dulo de alimentaci n si fuera independiente o desenchufar el cable del recept culo de la pared Protecci n del cables de alimentaci n Los cables de alimentaci n el ctrica se deben instalar en lugares donde no sean pisados ni apretados por objetos que se puedan apoyar sobre ellos Reparaciones mantenimiento Solicitar siempre los servicios t cnicos de personal calificado En el interior no hay partes a las que el usuario deba acceder Para evitar riesgo de electrocuci n no intentar personalmente la reparaci n mantenimiento de este equipo ya que al abrir o extraer las tapas puede quedar expuesto a voltajes peligrosos u otros riesgos Ranuras y abert
25. uras Si el equipo posee ranuras o orificios en su caja alojamiento es para evitar el sobrecalientamiento de componentes internos sensibles Estas aberturas nunca se deben obstruir con otros objetos Bater a de litio e Existe riesgo de explosi n si esta bater a se coloca en la posici n incorrecta Cambiar esta bater a nicamente con el mismo tipo o su equivalente recomendado por el fabricante Desachar las bater as usadas siguiendo las instrucciones del fabricante Precautions SEH e g RED Bai PX N
26. wis Street Beeldschermweg 6C 135 Joo Seng Rd 04 01 Kyodo Building 16 Ichibancho c Anaheim CA 92805 3821 AH Amersfoort The Netherlands PM Industrial Bldg Singapore 368363 Chiyoda ku Tokyo 102 0082 er oro 800 633 9876 714 491 1500 800 3987 6673 31 33 453 4040 800 7339 8766 65 6383 4400 Japan www extron com FAX 714 491 1517 FAX 31 33 453 4050 FAX 65 6383 4664 81 3 3511 7655 FAX 81 3 3511 2007 Extron Electronics All rights reserved

Download Pdf Manuals

image

Related Search

Related Contents

1771 UM001A-US-P - Rockwell Automation  Samsung 206BW manual de utilizador  Link to Artel Pipette Calibration System Quick Start Guide…  取扱説明書 KS-DA456ASPN/KS-DA556ASPN/KS  Ditec LOGIC M  OPERATOR`S MANUAL MANUEL de L`UTILISATEUR MANUAL del    Installationsanleitung für die autorisierte Fachkraft turbotec  System and method for retaining clients by automated services  B_capitolato copertura palestra Massa dic14  

Copyright © All rights reserved.
Failed to retrieve file