Home
E A S Y T E N S
Contents
1. The device must be used only by person with mental competence Do not use the stimulator near short wave devices Use destination VAN Read the operating manual carefully in order to avoid to carry out installation use and maintenance non adequate that could damage the apparatus the operator and the user The stimulators are used in the following operating enviromment and field home surgeries hospital physiotherapic surgery rehabilitation centres treatments of pain in general in any type of sequential electro stimulation Aesthetic and sports use The use of the stimulator is allowed to patients rightly informed about the methods doctors and paramedic The presence of clinic stimulation makes this product a medical device The certification cover the clinic applications It is forbidden the reproduction and the copy of this manual without written permission of producer ENG 10 11 Data di emissione 10 11 2010 22 TECHNICAL FEATURES Number of channels Out current Wave form Running frequency Impulse amplitude Supply Storage and transportation temperature Max relative humidity Atmospheric pressure Use conditions Temperature of use Max relative humidity Atmospheric pressure Weight Classification Certification 2 90 mA Square biphasic symmetrical compensated impulse 1 110Hz 50 300 us 3 batteries of 1 5V AAA type LR03 from 10 C to 45 C 75 from 700
2. This program is efficacious in case of stressed vertebral column The pain can be caused by an incorrect body position or for example by a prolonged per manence at the wheel or sitting at the writing desk The program helps the blood flow increasing eliminating the substance that causes the pain The effect is not immediate but it lasts for 6 12 hours It can be performed until the pain stops Intensity Pins and needles sensation without pain 5 CERVICAL Anthalgic current Tens Burst This pro gram is very useful for neck pain relief It can be performed every day until the pain stops Intensity pins and needles sensation without pain Should not cause muscle contractions 6 ARTHRITIS SHOULDER The program has a sedati ve anthalgic effect It relieves the chronic and acute shoul der pain The pain can be caused by a series of erroneous movement or by an intense physical work for example weight lifting It can be associated to an Endorphinic TENS program It can be performed every day until the pain stops Intensity pins and needles sensation without pain Should not cause muscle contractions 7 DRAINAGE The coordinated stimulation achieved by the two channels of the stimulator produces a muscular pumping effect starting at the extremity of the limb and spreading all the way to its root The pumping action mainly activates the venous but also the lymphatic system by mechanical effect Its objective is to improve the circu
3. lation and to promote the elimination of toxins It also helps to prevent the night cramp and it is useful for people who suffer of limb swelling Intensity Visible muscle vibration 8 ATROPHY MUSCULAR RESUMING The program is particularly useful after a period of interruptions After injuries or other interruptions in physical activity the muscle often lose strength and muscle mass It is important to restore normal muscle capacity as soon as possible This program gives the possibility to train specific muscles that are affected Intensity it is advisable to start with low intensity gra dually increasing Attention Seek medical advice for establishing time and work mode Programs and protocols of health and tens are generic suggestion about the treatments to be executed They must be confirmed by a doctor or specialist It is forbidden the reproduction and the copy of this manual without written permission of producer ENG 10 11 Data di emissione 10 11 2010 min Placement Ll heel i rca Peer __ _ di dn O P 6 Arthritis shoulder oie 7 Drame 05 o eee a B pew o 00 omm jo LEGEND LOW Barely perceptible contractions MODERATE Very bearable and tolerable contractions Visible muscular movement MODERATE and STRONG Obvious contraction but bearable MAXIMUM Maximum contraction Bearable but without pain Programs and protocols of health and tens are generic suggestion about the treatments to be
4. via San Felice 4 31020 San Vendemiano TV ITALY info domino tv it Distribuido da Globus Italia s r l via Vittorio Veneto 52 31013 Codogn TV ITALY Tel 39 0438 7933 info globusitalia com El equipo fue construido en conformidad a normativas tecnicas vigentes y fue sometido a certificaciones a sentidos de la directiva 93 42 CEE sobre dispositivos medicos Para mante ner el maximo nivel de seguridad el usuario debe utilizar el equipo respetando las prescripciones y los limites de empleo del manual de uso El productor rechaza cada responsabilidad en merito al uso diferente del que se indica y prescribe en el presente manual Sin el permiso escrito del productor se prohibe la reproducci n tambien parcial en cualquier forma o con cualquier metodo electr nico o mecanico de los textos y o fotos contenidos en este manual Ce produit est r alise par SAVIA L t d 2nd Industrial District Feng Huang Village Shenzen Made in PRC sales tyece com Mandataire Domino s r l via San Felice 4 31020 San Vendemiano TV ITALY info domino tv it Distribu par Globus Italia s r l via Vittorio Veneto 52 31013 Codogn TV ITALY Tel 39 0438 7933 info globusitalia com L appareil a t construit en conformit aux normes techniques en vigueur et a t soumis certification selon la directive 93 42 CEE sur les dispositifs medicaux Puor maintenir le niveau maximum de suret e l utilisateur doit utiliser l appareil dans
5. executed They must be confirmed by a doctor or specialist It is forbidden the reproduction and the copy of this manual without written permission of producer ENG 10 11 Data di emissione 10 11 2010 30 Why does the intensity return immediately to 0 when increasing its value The unit has a control of current supply In case the circuit is open the intensity is automatically shut off It is therefore necessary before starting any treatment to be sure that the cables are well connected and the electrodes completely placed on the skin What to do when the discharged battery indicator appears You can continue your stimulation until it starts diminishing then turn off the unit disconnect the electrode cables and change the batteries Is it possible to use the electric stimulator during the menstrual cycle Possible interferences like anticipations delays accentuations or reductions of the cycle can be subjective and varia ble It is however advisable to avoid treatments in the abdominal zone during the cycle Is it possible to use the electric stimulator during lactation Until now it has not found collateral effects in relation to the electric stimulator use during the lactation It is however advisable not to treat the thoracic zone Does the presence of dermatological diseases like psoriasis urticaria etc prevent the electric stimulator use Yes it is advisable not to treat epidermic zones which present important dermatological
6. permission of producer ENG 10 11 Data di emissione 10 11 2010 24 DISPLAY PROGRAM 1 E WA D c Mms Em The device has a big display which continuously gives information about the different parameters in use A Timer Shows the remaining time in minutes The timer zone consists of a circular graph representation which moves during the performance B Performance indicator The figures of small man and impulses indicate the correct execution of the program The represen ted graphic impulses are animated in different ways for each program When this zone is light it means that a program is in progress C Intensity graphic indicator The graphic bar shows the intensity level in use D Intensity numerical indicator Shows the used intensity level included from 0 to 20 scale E Program indicator Shows the selected program F Lock key indicator It shows that the keyboard is locked except for the ON OFF switch G Battery indicator The indicator lightens when the batteries are almost empty It is forbidden the reproduction and the copy of this manual without written permission of producer ENG 10 11 Data di emissione 10 11 2010 25 HOW 10 Use RI First use 1 AE e e L8 2 Turn the stimulator ON by pressing for three second the ON OFF key The stimulator automatically shows the last Attach the electrodes to the cable and place them on the skin See Placement of Electrodes chapter of this manual used progra
7. time 5 The warranty doesn t have effect in case of damages by bits falls improper or incorrect use not original external supply accidents alterations changes removal of warranty seals and or product infringement The warranty doesn t cover the damages caused during the transportation due to the use of inadequate boxing see art 1 6 The warranty doesn t cover the impossibility of using the product other occasional or consequential expenses or other purchaser expenses ATTENTION Before returning the machine to be repaired it is recommended to carefully read the user manual instruc tions In case of device breakdowns contact the shopkeeper before The fabricant can make at any moment all the neces sary modifications to improve the product aesthetic and quality It is forbidden the reproduction and the copy of this manual without written permission of producer ENG 10 11 Data di emissione 10 11 2010 32 ARTHRITIS SHOULDER CERVICAL UPPER LIMBS PAINS PERIARTRITE SCAPOLO OMERALE CERVICALI DOLORI ARTI SUPERIORI PROG 6 PROG 5 PROG 2 EPICONDYLITE BACKACHE KNEE PAIN EPICONDILITE MAL DI SCHIENA CONDRITE ROTULEA PROG 1 PROG 4 PROG 1 um SCIATICA DRAINAGE or ATROPHY ARTICULATION PAINS SCIATALGIA DRENAGGIO o RECUPERO MUSC DOLORI ARTICOLAZIONI PROG 3 PROG 7 8 PROG 1e 2 EGREGIO CLIENTE LA RINGRAZIAMO PER LA SCELTA EFFETTUATA E LE CONFERMIAMO LA NOSTRA PIU COMPLETA DISPONIBILITA PER QUALSIASI AIUT
8. Miniec Emme nid EASY TEN SN Lee USER MANUAL ai 0197 gt a SE ac EGREGIO CLIENTE LA RINGRAZIAMO PER LA SCELTA EFFETTUATA E LE CONFERMIAMO LA NOSTRA PIU COMPLETA DISPONIBILITA PER QUALSIASI AIUTO O SUGGERIMENTO DI CUI AVESSE BISOGNO Prodotto da SAVIA L t d 2nd Industrial District Feng Huang Village Shenzen Made in PRC sales tyece com Mandatario Domino s r l via San Felice 4 31020 San Vendemiano TV ITALY info domino tv it Distribuito da Globus Italia s r l via Vittorio Veneto 52 31013 Codogn TV ITALY Tel 39 0438 7933 info globusitalia com L apparecchiatura stata costruita in conformit alle norme tecniche vigenti ed stata sottoposta a certificazione ai sensi della direttiva 93 42 CEE sui dispositi vi medici Per mantenere il livello massimo di sicurezza l utente deve utilizzare l apparecchio nel rispetto delle prescrizioni e dei limiti di impiego del manuale d uso Il produttore declina ogni responsabilit in merito ad un uso difforme da quanto indicato e prescritto nel presente manuale Senza il permesso scritto del produttore sono vietati la riproduzione anche parziale in qualsiasi forma e con qualsiasi mezzo elettronico o meccanico di testi e o foto contenute in questo manuale Questo simbolo sul vostro apparecchio serve ad indicare che in conformit con 1 requi C siti delle direttive sugli apparecchi medici 93 42 CEE Il numer
9. O O SUGGERIMENTO DI CUI AVESSE BISOGNO Prodotto da SAVIA L t d 2nd Industrial District Feng Huang Village Shenzen Made in PRC sales tyece com Mandatario Domino s r l via San Felice 4 31020 San Vendemiano TV ITALY info domino tv it Distribuito da Globus Italia s r l via Vittorio Veneto 52 31013 Codogn TV ITALY Tel 39 0438 7933 info globusitalia com L apparecchiatura stata costruita in conformit alle norme tecniche vigenti ed stata sottoposta a certificazione ai sensi della direttiva 93 42 CEE sui dispositivi medici Per mantenere il livello massimo di sicurezza l utente deve utilizzare l apparecchio nel rispetto delle prescrizioni e dei limiti di impiego del manuale d uso Il produttore declina ogni responsabilit in merito ad un uso difforme da quanto indicato e prescritto nel presente manuale Senza il permesso scritto del produttore sono vietati la riproduzione anche parziale in qualsiasi forma e con qualsiasi mezzo elettronico o meccanico di testi e o foto contenute in questo manuale This product as been manufactured by SAVIA L t d 2nd Industrial District Feng Huang Village Shenzen Made in PRC sales tyece com Agency Domino s r l via San Felice 4 31020 San Vendemiano TV ITALY info domino tv it Distribuited by Globus Italia s r l via Vittorio Veneto 52 31013 Codogn TV ITALY Tel 39 0438 7933 info globusitalia com This product has been manufactured acc
10. diseases How long after is it possible to see the first results The aesthetic results obtained are always subjective It is however possible to state that you can achieve good results about tonicity after 15 days with 3 or 4 sessions a week for lypolisis and drainage treatment it is necessary at least 40 days Better and speeder results are obtained if treatments are combined with a good physical activity and a correct life style It is forbidden the reproduction and the copy of this manual without written permission of producer ENG 10 11 Data di emissione 10 11 2010 31 ANT I This product is warranted to the first user for a 24 month period from the purchase date against material defects or manu facturing provided that it is used properly and maintained in the normal efficiency conditions To enjoy the warranty service the user must observe the following warranty articles 1 The products must be delivered for repairing by the User in their original packaging the expenses are charged to the User 2 The product warranty depends on the presentation of fiscal document cash voucher fiscal receipt or selling invoice and certifying the purchase date of the product 3 The repairing will not have effect on the original date of warranty expiration and will not mean the renewing or exten sion of the warranty 4 When during the repairing will not be found any defect will be in any case charged the expenses related to the chec king
11. es with 8 electrodes Case of 4 reusable adhesive electrodes 5 x 5 cm Conductive band for legs Case of 4 reusable adhesive electrodes 5 x 9 cm Face electrodes 3 battery stylos 1 5 V AAA Y cables Operating manual Gel This stimulator is supplied complete of cables and electrodes When you open the packing verify that the simulator equip ment is complete If some of the above mentioned accessories are missing you should immediately contact the shopkee per Also check the stimulator and electrodes integrity Electrodes The electrodes are usable by only one user they are self adhesive and do not need gel The electrode cable is female They are branded CE complied with MDD 93 42 EEC requirements All the information can be subject to changes without notice The symbols mean that the apparatus is in accordance with medical CE requirements type BF It is forbidden the reproduction and the copy of this manual without written permission of producer ENG 10_11 Data di emissione 10 11 2010 20 PRECAUTIONARY MEASU A This symbols warns you to read the operating instructions prior to use Contraindications Do not stimulate the neck region carotid sinus Patients who have a demand type cardiac pacemaker Stimulation should be not used on cancer patients previous permission received by the oncologist Do not stimulate the cerebral zone Do not use on undiagnosed pains until aetiology is established Do not use on sore
12. hPa to 1060 hPa from 0 C to 40 C from 30 to 75 from 700 hPa to 1060 hPa 95 gr Power supply type BF Certificate CE MDD Medical Device Directive The name of producer is reported in the last page Device removal Don t throw the battery or electrodes out but recycle or get rid of them appropriately following the removal rules in force in your country It is forbidden the reproduction and the copy of this manual without written permission of producer ENG 10_11 Data di emissione 10 11 2010 23 DESCRIPTION OF THE P ON OFF key Press for three seconds for turning the stimu lator ON Press for three seconds for turning the stimu lator OFF This switch can be used during the treatment as a Stop button LOCK key Display To lock all keys except Indicates mode parame for the ON OFF key ters etc press for 3 seconds To unlock the keys press for 3 seconds again Program key Press this key to select the program Intensity key of the left Intensity key of the right channel channel Press the key with the Press the key with the arrow to increase the out arrow A to increase the out intensity of the left chan intensity of the right chan nel nel Press the key with the Press the key with the arrow W to decrease the arrow W to decrease the out out intensity of the left intensity of the right chan channel nel It is forbidden the reproduction and the copy of this manual without written
13. le respect des prescriptions et des limites d emploi du manuel d utilisation Le producteur d cline toute responsabili t en cas d utilisation difforme de ce qui est indiqu et prescrit dan ce manuel Sans l autorisation crite par le producteur toute reproduction meme partielle sous toute forme ou l aide de moyens lectroniques ou m caniques des textese et des photos contenues dans ce manuel est interdite
14. m The intensity indicator is positioned on 0 in both channels Select the program you want to perform pressing the P key Increase the used channel intensity by pressing the arrow of L switches 4 Increase the intensity until the wished level maintaining a pleasant feeling To decrease the intensity press the arrow Y Increase the used channel intensity by pressing the arrow of R switches Increase the intensity until the wished A level maintaining a pleasant feeling To decrease the intensity press the arrow Y Every time you want to turn off the stimulator press the ON OFF key It can be used as an emergency button NOTE Each program has a predefined duration time The intensity resets to 0 when the program ends It is forbidden the reproduction and the copy of this manual without written permission of producer ENG 10 11 Data di emissione 10 11 2010 26 How to pause the program You can pause the program by pressing the ON OFF switch Start the stimulation by pressing the On OFF switch again The program continues where the stimulation was shut off Automatic functions Automatic Switching off If the electric stimulator is not in use for more than 5 minutes and the intensity in both channels is on 0 the stimulator automatically switches off Electrode contact If the electrodes are not correctly placed on the skin or the cables are not well connected the intensity of channels is automatically shut off
15. o dell ente notificato 0197 0197 A Questo simbolo significa Attenzione consultare le avvertenze Parti applicate BF Conforme RoHS A Il simbolo indica la raccolta separata delle apparecchiature elettriche ed elettroniche si RoHS II CE0197 non si riferisce ai trattamenti non di tipo medicale Gli avvisi sonori e acustici sono conformi alla direttiva 60601 1 1 Manuale d uso Rev ITA 10 11 Data di emissione 10 11 2010 2 E vietata la riproduzione e la copia senza espressa autorizzazione del produttore an lt e Z INDEX Accessories Precautionary measures Palm technical features Electrode and battery removal Description of the Palm Display How to use the Palm First use How to pause the program Automatic function Automatic switching off Electrode contact Empty battery Memory function Intensity of stimulation Special functions Keyboard lock key Battery replacement How to connect the cables How to place the electrodes Index of the programs Programs List Common questions Guarantee terms Electrode Placement It is forbidden the reproduction and the copy of this manual without written permission of producer ENG 10_11 Data di emissione 10 11 2010 20 21 23 24 25 26 28 28 28 29 30 31 32 33 19 Accessories Accessories on request Electro stimulator Ball pen Carry case Kit splitter 2 connectors 2 connection cables 4 channels 2 connection cabl
16. of switches during the treatment The keyboard lock is released when the key is pressed for three seconds again Note You cannot change the intensity value during the rump up and ramp down in all intermittent programs which foresees cycles of work and recovery It is forbidden the reproduction and the copy of this manual without written permission of producer ENG 10 11 Data di emissione 10 11 2010 27 Battery replacement Shut off the stimulator Remove the battery cover by sliding it downwards and take out the batteries Placed 3 alkaline batteries of 1 5V AAA type LR03 and close the cover Make sure that the new batteries are correctly placed with respect to the polarity note marks for and Electrode and battery removal Don t throw the batteries or electrodes out but recycle or get rid of them appropriately following the removal rules in force in your country How to connect the cables It is possible to use one or two cables depending on use of one or two channels Connect the cable connector to the relative output placed on the inferior part of the unit The outputs are exactly below the correspondent channel left or right How to place the electrodes Remove the electrodes from the original wrapping and connect the cable plugs to them Place the electrodes on the skin following the images present in this manual At the end of the treatment put back the electrodes in their special seat Note The new electrodes have a herme
17. ording to the technical regulations in force and it has been subjected to certifications according to 93 42 CEE directiv for medical devices in order to assure the product s security The user must follow all prescriptions and restrictions shown in the operating manual in order to keep the maximum security level of the product The manufacturer declines all responsibility for every different use from what indicated in this operating manual All complete or partial reproductions of texts and or pictures of this opera ting manuals made by any electronic or mechanic equipments are strictly forbidden without written permission of the manufacturer Die Ger t ist aufgebauet von SAVIA L t d 2nd Industrial District Feng Huang Village Shenzen Made in PRC sales tyece com Beauftragte Domino s r l via San Felice 4 31020 San Vendemiano TV ITALY info domino tv it Vertretet von Globus Italia s r l via Vittorio Veneto 52 31013 Codogn TV ITALY Tel 39 0438 7933 info globusitalia com CE Die Ger t ist in bereinstimmung mit der EU Verordnung ber medizinische Ger te 93 42 CEE die die Sicherheit dieses Produktes gew hrleistet hergestellt worden Der Hersteller beh lt sich alle Urheberrechte im Hinblick auf die Texte und Fotos dieses Handbuchs vor Kopien sind untersagt Este producto est costruido SAVIA L t d 2nd Industrial District Feng Huang Village Shenzen Made in PRC sales tyece com Mandatario Domino s r l
18. s and dermatological diseases Do not use on acute traumas Do not stimulate recent cicatrix Do not use during pregnancy Do not use driving car It is absolutely forbidden to stimulate the ocular and genital zone It is also forbidden the use of the stimulator in the water it is not protected against the water seepage Not to use the stimulator in environment where combustible gas inflammables or oxygen are present Adverse possible effects AN It is also required to use with caution in case of capillary fragility because an excessive stimulation could cause the break of more quantity of capillaries Anyway it is always preferable to contact your doctor befo Skin irritation can occur in rare case In case of allergic reactions by the use of gel stop the treatment and contact the specialist doctor re using If during the stimulation treatment tachycardia or extrasistolia should appear it is better to stop the treatment the sen sation will pass immediately Precautions for usin VAN Do not make any modifications or repairs by yourself Authorized centres can only execute the repairs Do not give a shock to the product by clashing overturning or shaking It may cause a trouble or accident in a long run although no immediate trouble occurs Store the electro stimulator at a place free from a splash or water Avoid installing at places subject to undue humi dity temperature dust or places exposed to direct sunbeam Do not u
19. se thinner gasoline kerosene cleaning powder or chemicals for cleaning the machine it is sufficient a soft duster Take away the battery from the electro stimulator in case of prolonged no use After a long period of no use it is advisable to check the correct working For cleaning the machine and the cables it is sufficient a soft duster lightly humid It is forbidden the reproduction and the copy of this manual without written permission of producer ENG 10_11 Data di emissione 10 11 2010 21 Warnings The stimulator must be used only for transcutaneous neuro stimulation The neurostimulation apparatus should be used only under the continued supervision of a physician The stimulator should be only used with skin electrodes intended for nerve and muscle stimulation The user must keep the device out of reach of children Electronic monitoring equipment such as ECG monitors and ECG alarms may not operate properly when stimula tion 1s In use Stimulus delivered by this device may be sufficient to cause electrocution Electrical current of this magnitude must not flow through the thorax because it may cause a cardiac arrhythmia Do not use the apparatus in case of any health problem without consulting your doctor Incase of damage of the covering apparatus this has to be replaced Itis advisable not to use the apparatus together with other electronic equipment above all those used for support of vital functions
20. tic wrapping therefore check that they are new and supplied together with the unit ATTENTION Don t remove the electrodes when the unit is working A It is forbidden the reproduction and the copy of this manual without written permission of producer ENG 10_11 Data di emissione 10 11 2010 28 INDEX OF THE PROGRAMS 1 TENS TENS allow the relaxation of the muscle as well as pain relief TENS utilises the nervous system s own pain relief mechanism to ease both acute and chronic pain It can be used for muscular or articulation pains sciatica and for feet knee and back pains The treatment can be performed every day until the pain disappears 2 TENS ENDORPHINIC This treatment can be perfor med every day until the pain disappears and it can be alter nated with the other TENS treatments The stimulation with light contractions causes the circulation increasing and helps the muscles to relax The effect induced by the relea se of endorphins causes a delayed analgesic action but that continues for hours 6 12 hours 3 SCIATICA The program is ideal for people who suffer of pain caused by the sciatic nerve inflammation The pain often starts from the lumbar zone and spreads until feet Place the electrodes on the painful leg as specified in the images of this manual It can be performed every day until the pain disappears Intensity pins and needles sensation without pain Should not cause muscle contractions 4 BACKACHE
21. to 0 In case the electrodes are not correctly placed before starting a treatment it is not possible to increase the channel intensity This is a security measure to preserve the user from unpleasant possible effects Empty battery The battery indicator lights up on the display when the batteries are almost empty As long as stimulation feels the same as usual you can continue the treatment It is time to replace the batteries when stimulation starts diminishing or the stimulator shuts off Memory function The electric stimulator keeps on the memory the last performed program which is repurposed when you turn on the stimulator again The memory function takes back the unit to the first program every time you change the batteries Intensity of stimulation The intensity value for obtaining a special contraction is completely subjective It can depend on a series of factors like as the electrode position the adipose stratum the perspiration etc For these reasons the same current intensity value can give different sensations from a person to another from a day to another or furthermore you could feel more contraction on the left limb rather than the right one You have to regulate it on the bases of your sensations Special Functions Keyboard lock key When you have reached the wished intensity level you can lock the keys except for the ON OFF switch by pressing the LOCK key for 3 seconds This function will avoid you the accidental use
Download Pdf Manuals
Related Search
Related Contents
microKONTROL owner`s manual Manuale tecnico GMWW Fisher & Paykel Intuitive DEIX1 User's Manual Guida all`implementazione di CA ARCserve Backup per Windows PDF - 取扱説明書 Supermicro X9SRL-O Retail Proposal Example - Electrical and Computer Engineering Department User`s Manual mesas para comida caliente Quantium 510 Manuel d`Installation Copyright © All rights reserved.