Home
        LEISTER LE 5000 HT (without electronics) Electric Hot Air Tool
         Contents
1.  element housing and nozzle when  hot as they can cause burns  Do not point the hot air  flow at people or animals     AN CAUTION    230  400        0       TECHNICAL DATA    Voltage   Power consumption  Frequency   Min  Airflow   Max  Temp    Max  Temp    Size LxBxH  Weight    The voltage rating stated on the tool should corre   spond to the mains voltage     The tool should be earthed using a protective  conductor     Protect the tool from damp and wet     The equipment should not be operated without  supervision     V  3 x 400   kW 10800   Hz 50 60   l min  635   XS 900   oe 1650   mm 37 9 X NOE x 112  kg 229       USAGE LEISTER LE 5000 HT without electronics    Description of tool       Protective sleeve for cable  to mains    Air intake connection    38  Connection housing  Installation stand    Element housing with  protective sleeve    akRwnN             Lf f   12 34 5    Installation    e The tool should be fixed by using four M4 screws on the installation stand  4    e When installing the tool  ensure that      only cold air is sucked in     no  warm air  back pressure develops     the hot air tool is not in direct line of another hot air tool   e Protect the tool from vibration and shock     e Installation dimensions in mm                                     Air supply   e To protect the tool and the element  the air flow must under no circumstances  fall below the specified minimum  and the maximum temperature  measured 3  mm in front of the element housing  must u
2. OPERATING INSTRUCTIONS LEISTER    LEISTER LE 5000 HT  without electronics   Electric Hot Air Tool  900   C 1650  F     T Please read operating instructions carefully before use and  LN keep for further reference     APPLICATION    e The LEISTER Hot Air Tool type 5000 HT is suitable for building into machines   installations or appliances and is designed for continuous operation    e Drying and heating processes of various types    e Shrinking and welding packaging films and moulded parts    e Heating conveyor ovens or heat tunnels    e Activating and loosening solvent free adhesives and melt adhesives    e Sterilizing packaging materials such as bottles  corks and containers    e Separating and fusing synthethic fibres and fabrics    e Soldering processes on thin metal parts    e Speeding up mixing processes and dissolving foams which can arise during  mixing and filling operations    e Removing plastic mould flash and putting a shine on plastic surfaces        LEISTER Process Technologies  Riedstrasse  CH 6060 Sarnen   Switzerland  Tel   41 41 662 7474 Fax  41 41 6627416 www leister com  sales leister com  1    AN WARNING     gt e D    Danger  When opening up the tool  live components  and connections are exposed  Therefore  before open   ing it  unplug the tool to ensure disconnection from  the mains     Incorrect installation and use of hot air tools can  present a fire and explosion hazard  The specified  minimum air flow must be absolutely adhered to     Do not touch the
3. nder no circumstances be exceeded   Should the air flow be interrupted or the air flow fall below the minimum  the  mains must be disconnected at the same time     e LEISTER blowers must be used for the air supply  pay attention to the direction of  rotation and the electrical connection     e For use in a dusty environment the tool should be fitted with a LEISTER stainless  steel filter on the air intake connection  Where a particularly critical dust pro   blem exists  eg metal  electrically charged or damp dust  special filters must be  used to avoid short circuiting the tool    e The hot air tool should only be supplied with air up to a max  100  C     BA LE 5000 HT without electronics  06 2001 GB    Operation    Connect tool to the mains    The mains connection cable should have the corresponding cross section area  of conductor and should be fitted by a specialist    As required  push fit appropriate nozzle or reflector  see caution     Make sure that the hot air can flow freely as otherwise back pressure could da   mage the tool  fire hazard     The LEISTER Company  as well as the authorized Sales and Service Centres  offer  advice and an introduction to the areas of application of hot air tools  free of  charge  see page 1     After use  allow the tool to cool down by letting cold air flow through it  pre   venting warm air back pressure      CAUTION       To protect the tool as well as the element  the minimum air flow  see page 2   must in no way be impeded through n
4. ozzles or reflectors        The mains connection should have a suitable double pole isolator with a 3 mm  distance between contacts     ACCESSORIES    e Only LEISTER accessories should be used   e Let the tool cool down before changing the nozzle or reflector     SERVICE AND REPAIR    e Repairs have to be carried out by authorised LEISTER Service Centres only  They  guarantee a specialized and reliable repair service within 24 hours using original  LEISTER spare parts     GUARANTEE AND LIABILITY    e Guarantee and liability are in accordance with the guarantee certificate as well  as with the currently valid general business and sales conditions     e LEISTER Process Technologies rejects any guarantee claims for tools which are not  in their original condition  The tools must never be altered or changed     Technical data and specifications are subject to change without prior notice     Your authorized Service Centre is     LEISTER Process Technologies  Riedstrasse  CH 6060 Sarnen   Switzerland  Tel   41 41 662 7474 Fax  4141 6627416 www leister com  sales leister com  4    
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Manual de Usuario  Samsung AQ09MSDN User Manual  SKF Online Motor Analysis System NetEP/iNetEP User Manual  Service bulletin  dual diaphragm condenser microphone b-2 pro  X-HM81-S/-K  レスキューパラシュートについて 2007年7月 スクール・事業委員会 委員  48" Deck Manual  - Deines Manufacturing  The Introduction of ORICO 3549RUS3  Fwmaggate    Copyright © All rights reserved. 
   Failed to retrieve file