Home

USER MANUAL - Kramer Electronics Japan Homepage

image

Contents

1. 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Fully compatible with power plugs in the UK India Italy and Denmark as well as with the 2 prong Europlug Partially compatible if the polarity is reversed with plugs in China Switzerland Israel and the USA The universal socket does not supply grounding to plugs in Central Europe and France you should order country specific sockets instead Not compatible with South African plugs TBUS PS US 80 000999 100 240V AC 50 60Hz 5A Maximum 5A per power outlet TBUS 1A Your TBUS 1A Enclosure Single Power Socket Assemblies Power Specs Germany and EU TBUS PS DE 80 001299 100 240V AC 50 60Hz 5A Maximum 5A per power outlet TBUS PS FR 80 001399 100 240V AC 50 60Hz 5A Maximum 5A per power outlet TBUS PS ITALY 80 001499 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Australia TBUS PS AUS 80 001599 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Legrand manufactured sockets for various TBUS PS LEGRAND 80 001799 countries For example the Legrand assembly with a UK power socket 100 240V AC 50 60Hz 5A Maximum 5A per power outlet TBUS 1A Your TBUS 1A Enclosure Dual Power Socket Assemblies Power Specs Universal TBUS DUAL PS UNIV 80 001899 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet USA TBUS DUAL PS US 80 001999 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet Germany
2. Europe AC POWER CORD 6ft Y 220V 91 000499 240V Y version 6ft UK AC POWER CORD 6ft Y 240V 91 000599 5 5 1 5 1 1 Installing the TBUS 1A To install the TBUS 1A perform the following steps 1 Assemble the inner frame see Section 5 1 2 Install the inner frame See Section 5 2 3 Cutan opening in the table see Section 5 3 4 Insert the unit through the opening and secure to the table see Section 5 4 5 Connect the pass through cables see Section 5 5 6 Connect the cables see Section 5 6 7 Adjust the height of the inner frame see Section 5 7 Assembling the Inner Frame The modules mounted on the inner frame can include single inserts and or dual inserts as well as power sockets and various Kramer devices This section describes how to assemble these modules Each module kit comes with detailed assembly instructions Mounting the Inserts You can rearrange or remove any of the plates mounted on the inner frame and replace them with Kramer passive wall plates or connector modules for interfacing A V type signals To mount a Kramer insert or connector module 1 Unscrew the two screws that fasten the blank plate to the inner frame and remove the blank plate 2 Place the required Kramer insert over the opening insert the two screws to fix the Kramer insert in place and tighten them 5 1 2 Figure 3 TBUS 1A Inner Frame P N 80 000299 Feature Function 1 Blank Plates Fou
3. France 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet Legrand 100 240V AC 50 60Hz 5A manufactured sockets for various countries FUSE RATING T 6 3A 250V OPERATING TEMPERATURE 5 to 45 Deg Centigrade RANGE OPERATING HUMIDITY 10 to 90 RHL non condensing RANGE STORAGE TEMPERATURE 20 to 70Deg C RANGE Maximum 5A 2 5A per power outlet IA lechnical opecitications ot the Assempied 1IBUS I1A LILI STORAGE HUMIDITY RANGE 5 to 95 RHL non condensing DIMENSIONS 22 1cm x 18 2cm x 13cm 8 17 x 5 88 x 5 13 W D H WEIGHT TBUS 1A 1 5kg 3 3lbs approx Table clamps 0 26kg 0 57Ibs Metal template 0 125kg 0 28lbs ACCESSORIES Power cord six self locking ties metal template OPTIONS Inner frames passive wall plates and interfaces power socket kits power cord Specifications are subject to change without notice at http www kramerelectronics com LIMITED WARRANTY We warrant this product free from defects in material and workmanship under the following terms HOWLONGIS THE WARRANTY Labor and parts are warranted for seven years from the date of the first customer purchase WHOIS PROTECTED Only the first purchase customer may enforce this warranty WHAT IS COVERED AND WHAT IS NOT COVERED Except as below this warranty covers all defects in material or workmanship in this product The following are not covered by the warranty 1 Any product which is not distributed by us or whic
4. TBUS 1A features A modular design letting you tailor the TBUS 1A according to your requirements A brushed aluminum lid with a special opening for cable pass through available in black and brushed clear note that other customized colors can also be ordered An inner frame that can be set to one of five possible height adjustments Note that the inner frame is ordered separately Power socket openings that are suitable for any of the following power sockets for the USA Germany the Europlug Belgium France Italy Australia Universal for use anywhere see compatibility restrictions in Section 7 or Legrand type power sockets for use with Legrand s white Mosaic series only Order the power sockets separately from Kramer Electronics Power socket openings for which you can order any of the following power sockets USA Germany EU Belgium France Italy Australia Universal for use anywhere see compatibility restrictions in Section 7 or Legrand type power sockets from the Mosaic Series white only Figure 1 TBUS 1A Inside a Table Do not place heavy objects on top of the TBUS 1A 4 Your TBUS 1A Enclosure SVS lt SsSssgss Figure 2 TBUS 1A Enclosure Top View Feature Function 1 Black Brushed Clear Includes an opening for cable pass through covers the inner Textured Lid frame leaving the table surface neat and tidy 2 Outer Rim Fits over the table surface A protective rubb
5. cables Place the split bracket around the grommet and position this assembly over the inner frame Place the two screws appropriately and tighten the split bracket together with the grommet and inserted cables to the inner frame Insert the self locking ties through the tie holes to secure the cables to the inside walls of the enclosure Figure 6 4 cable Pass through Insert P N 80 000399 5 6 9 7 Connecting the Cables When replacing blank inserts with connector inserts for example VGA audio HDMI and so on 1 Insert the cables to their appropriate connectors from underneath 2 Secure the cables to the tie holes on the TBUS 1A Do not secure the cables too tightly or too loosely Leave a small amount of slack Adjusting the Height of the Inner frame If needed you can adjust the inner frame to one of five possible heights to accommodate large or bulky cables To adjust perform the following 1 Remove the eight height adjustment screws two screws on the front and back two screws on each side as shown in Figure 2 while supporting the surface from underneath with your fingers 2 Raise or lower the inner frame to the required height insert the screws and tighten them in place 6 Using the TBUS 1A Once the TBUS 1A is installed you can easily customize it to suit your own requirements by plugging in the required A V equipment as illustrated in the example in Figure 7 Video C
6. installed in the TBUS 1A enclosure Inner Frames for TBUS 1A Specifications define what you can include in this inner frame TBUS 1A IF 1XPS P N 80 000299 1 power socket 2 cable pass through inserts 4 blank inserts TBUS 1A IF 2XPS P N 80 000399 2 power sockets 2 cable pass through inserts 4 blank inserts TBUS 1A IF 4XPS P N 80 000499 4 power sockets 2 cable pass through inserts 2 blank inserts Special Panel for RC 8IR P N 80 000599 1 special panel to fit the Kramer RC 8IR Control Panel into the appropriate frame P N 80 000399 or P N 80 000499 instead of two power sockets TBUS 1A Your TBUS 1A Enclosure EN 4 3 TBUS 1A IF SI 1VGA RC 3TB P N 80 000699 1 power socket 1 opening for Kramer SI 1VGA RC 3TB 2 cable pass through inserts 2 blank inserts Custom made inner frames can be designed if required Contact Kramer Electronics for more details Power Socket Options A choice of one or more power sockets per inner frame is available in several versions including power sockets for the USA Germany the Europlug Belgium France Italy and Australia A Universal socket for general use is also available see the compatibility restrictions in the table below as well as Legrand manufactured sockets the Mosaic series only which comes in white that are suitable for various countries Single Power Socket Assemblies Power Specs Universal TBUS PS UNIV 80 000899
7. 3 inches or less 152 2mm 191 2mm Figure 4 Cut out Dimensions 4 Unscrew and remove the template from the surface of the table and clean the table surface Take care not to damage the table If needed you can download a full scale template from our Web site Kramer Electronics is not responsible for any damage caused to the 5 4 Inserting the TBUS 1A through the Cut Out Opening To install TBUS 1A in the opening 1 Remove the protective rubber guard from around the outer rim of the TBUS 1A housing Beware of the sharp edge Carefully insert the unit into the prepared opening see Figure 5 Take the support brackets under the table and place them into the support bracket grooves on both sides of the unit See Figure 2 item 7 Verify proper alignment of the unit before tightening the mounting screws Screw both mounting butterfly screws upward until they reach the table surface from underneath Tighten firmly see Figure 5 Screw the locking butterfly screws downward until tight against the mounting bracket Figure 5 Inserting TBUS 1A into the Prepared Opening 5 5 Connecting the Pass through Cables To insert the pass through cables for example to connect a laptop do the following 1 Remove the two screws attaching the split pass through bracket Remove the split grommet Insert the cable through the rectangular opening Open the split grommet slightly and insert the reguired
8. A Enclosure Top View Figure 3 TBUS 1A Inner Frame P N 80 000299 Figure 4 Cut out Dimensions Figure 5 Inserting TBUS 1A into the Prepared Opening Figure 6 4 cable Pass through Insert P N 80 000399 Figure 7 TBUS 1A Boardroom Installation OO 01 01 WNHNN Introduction Welcome to Kramer Electronics Since 1981 Kramer Electronics has been providing a world of unique creative and affordable solutions to the vast range of problems that confront the video audio presentation and broadcasting professional on a daily basis In recent years we have redesigned and upgraded most of our line making the best even better Our 1 000 plus different models now appear in 11 groups that are clearly defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Matrix Switchers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP 7 Scan Converters and Scalers GROUP 8 Cables and Connectors GROUP 9 Room Connectivity GROUP 10 Accessories and Rack Adapters and GROUP 11 Sierra Products Thank you for purchasing the Kramer TBUS 1A which is ideal for boardrooms conference and training rooms 2 Getting Started We recommend that you e Unpack the equipment carefully and save the original box and packaging materials for possible future shipment e Review the contents of this user manual e Use Kramer high performa
9. KRAMER ELECTRONICS LTD USER MANUAL MODEL MODULAR TBUS 1A Table Connection Bus P N 2900 300055 Rev 1 TBUS 1A Quick Start Guide This page guides you through a basic installation and first time use of your TBUS 1A For more detailed information see the TBUS 1A user manual and modular instruction sheets You can download the latest manual at http www kramerelectronics com Step 1 Check what s in the box M TBUS 1A Table Connection Bus Enclosure A 1 Cut out Template 2 table clamps 1 Quick start guide AH 6 self locking ties 1 User Manual Step 2 Prepare the TBUS 1A for mounting Step 3 Prepare the table for mounting Cut out an opening in the table using the cut out template Step 4 Install the TBUS 1A to the table Contents 1 Introduction 2 Getting Started 2 1 Achieving the Best Performance 2 2 Glossary 3 Overview 4 Your TBUS 1A Enclosure 4 1 TBUS 1A Optional Inserts 4 2 TBUS 1A Optional Inner Frames 4 3 Power Socket Options 4 4 Power Cord Options 5 Installing the TBUS 1A 5 1 Assembling the Inner Frame 5 2 Installing the Inner Frame 5 3 Cutting an Opening in the Table 5 4 Inserting the TBUS 1A through the Cut Out Opening 2 5 Connecting the Pass through Cables 5 6 Connecting the Cables 8 7 Adjusting the Height of the Inner frame 6 Using the TBUS 1A 7 Technical Specifications of the Assembled TBUS 1A Figures Figure 1 TBUS 1A Inside a Table Figure 2 TBUS 1
10. and EU TBUS DUAL PS DE 80 002199 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet France TBUS DUAL PS FR 80 002299 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet TBUS DUAL PS ITALY 80 002399 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet Australia TBUS DUAL PS AUS 80 002499 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet Legrand manufactured sockets for various TBUS DUAL PS LEGRAND 80 002699 countries For example the Legrand assembly with a UK power socket 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet All the sockets come in black except for Legrand s white Mosaic series sockets that come in white Assembly instructions come with each power socket kit TBUS 1A Your TBUS 1A Enclosure 4 4 Power Cord Options You can order any of the following power cords to use with the TBUS Power Cord Type Description P N 220V Israel 250V UK AC POWER CORD 6ft UK 250V 91 000299 250V India Right Angle AC POWER CORD INDIA R A 6ft 250V 91 001099 250V 10A China Right Angle AC POWER CORD CHINA R A10A 6f 250V 91 001199 250V 10A South Africa AC POWER CORD SAA 10A 6ft 250V 91 001299 To use one power cord for a 4 socket configuration you can order any of the following types of power cords separately Power Cord Type Description P N 110V Y version 6ft North America AC POWER CORD 6tt Y 110V 91 000399 220V Y version 6ft
11. er guard protects the outer rim during shipping Remove it before installing the unit Inserted into the table cut out 4 Height Adjustment The screw holes are used for installing Kramer TOOLS Screw Holes TOOLs 5 Tie Holes Insert the self locking tie through the holes to fix the pass through cables to the inside walls of the unit 6 pairs of holes 3 for the front panel and 3 for the rear panel Bracket Slits Located on the front and rear panels and on both sides of the unit For attaching the two mounting brackets on opposite sides 7 Rubber Protect the table surface when mounting the unit and ensure soft Protectors tightening to the table underside one on each side Locking Butterfly Tighten to lock the mounting butterfly screw one on each side Screws Mounting Tighten to secure the unit to the table surface one on each side Butterfly Screws 10 Mounting Place in the bracket slits after inserting the enclosure into the table Brackets 2 units for securing the unit to the table surface one on each side Inner Frame Height The screw holes on each side panel are used for adjusting the Table Clamping Set Adjustment Screw height of the inner frame eight height adjustment screws are Holes included 4 1 TBUS 1A Optional Inserts You can install any wall plate devices as well as any of the single or dual inserts see our Web site for details 4 2 TBUS 1A Optional Inner Frames The following inner frames can be
12. h is not purchased from an authorized Kramer dealer If you are uncertain as to whether a dealer is authorized please contact Kramer at one of the agents listed in the Web site www kramerelectronics com 2 Any product on which the serial number has been defaced modified or removed or on which the WARRANTY VOID IF TAMPERED sticker has been torn reattached removed or otherwise interfered with 3 Damage deterioration or malfunction resulting from i Accident misuse abuse neglect fire water lightning or other acts of nature ii Product modification or failure to follow instructions supplied with the product iii Repair or attempted repair by anyone not authorized by Kramer iv Any shipment of the product claims must be presented to the carrier v Removal orinstallation of the product vi Any other cause which does not relate to a product defect vii Cartons equipment enclosures cables or accessories used in conjunction with the product WHAT WE WILL PAY FOR AND WHAT WE WILL NOT PAY FOR We will pay labor and material expenses for covered items We will not pay for the following 1 Removalor installations charges 2 Costs of initial technical adjustments set up including adjustment of user controls or programming These costs are the responsibility of the Kramer dealer from whom the product was purchased 3 Shipping charges HOW YOU CAN GET WARRANTY SERVICE 1 To obtain service on you product you must take or ship it
13. nce high resolution cables Go to http www kramerelectronics com to check for up to date user manuals a complete list of Kramer wall plates and module connectors application programs and to check if firmware upgrades are available where appropriate 2 1 Achieving the Best Performance To achieve the best performance e Use only good quality connection cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables e Avoid interference from neighboring electrical appliances that may adversely influence signal quality e Position your Kramer TBUS 1A away from moisture excessive sunlight and dust 2 2 Glossary Inner frame The inner frame fits into the TBUS enclosure Legrand socket For use with Legrand s white Mosaic series only Universal socket The Universal socket fits almost all power cords worldwide Insert The insert is fitted in the inner frame Go to our Web site to check for a variety of single and dual sized inserts Overview The TBUS 1A is a modular furniture mounted connection bus that is easily installed into a table or podium top The TBUS 1A lets you connect any equipment to the room s presentation system installations via cable access or passive interfaces see Figure 1 When the cables are not in use they can be stored inside the unit covered by the lid and out of sight In addition the
14. ned from your dealer This equipment has been tested to determine compliance with the requirements of EN 50081 Electromagnetic compatibility EMC generic emission standard Part 1 Residential commercial and light industry EN 50082 Electromagnetic compatibility EMC generic immunity standard Part 1 Residential commercial and light industry environment CFR 47 FCC Rules and Regulations Part 15 Radio frequency devices Subpart B Unintentional radiators CAUTION E Servicing the machines can only be done by an authorized Kramer technician Any user who makes changes or modifications to the unit without the expressed approval of the manufacturer will void user authority to operate the equipment E Use the supplied DC power supply to feed power to the machine ID Please use recommended interconnection cables to connect the machine to other components FCC and CE approved using STP cable for twisted pair products For the latest information on our products and a list of Kramer distributors visit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site www kramerelectronics com E mail info kramerel com SAFETY WARNING Disconnect the unit from the power m supply before opening and servicing
15. onference Communicatio Display Kramer Switcher Scaler Ethernet Q N J222222222223333233333 Ethernet M VGA D gt 7 Ss Computer Graphics gi Power Amplifier Source Laptop Projector with Speakers 4 A V Figure 7 TBUS 1A Boardroom Installation ESE TBUS 1A Using the TBUS 1A T Technical Specifications of the Assembled TBUS 1A POWER SOURCE Single Socket Assemblies AC power limits Universal 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Fully compatible with power plugs in the UK India Italy and Denmark as well as with the 2 prong Europlug Partially compatible if the polarity is reversed with plugs in China Switzerland Israel and the USA The universal socket does not supply grounding to plugs in Central Europe and France you should order country specific sockets instead Not compatible with South African plugs USA 100 240V AC 50 60Hz 5A Inman per ovr ce Germany and EU 100 240V AC 50 60Hz 5A pr Insane gover Belgium and France 100 240V AC 50 60Hz 5A je e cel Italy 100 240V AC 50 60Hz 5A yin poet Australia 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Legrand manufactured 100 240V AC 50 60Hz 5A sockets for various countries Mosaic Series Co paali Power Kit Assemblies Universal 100 240V AC 50 60Hz 5A A A eee USA 100 240V AC 50 60Hz 5A AA i lt Germany and EU 100 240V AC 50 60Hz 5A RE 5 Maximum 5A per power outlet
16. prepaid to any authorized Kramer service center 2 Whenever warranty service is required the original dated invoice or a copy must be presented as proof of warranty coverage and should be included in any shipment of the product Please also include in any mailing a contact name company address and a description of the problem s 3 For the name of the nearest Kramer authorized service center consult your authorized dealer LIMITATION OF IMPLIED WARRANTIES All implied warranties including warranties of merchantability and fitness for a particular purpose are limited in duration to the length of this warranty EXCLUSION OF DAMAGES The liability of Kramer for any effective products is limited to the repair or replacement of the product at our option Kramer shall not be liable for 1 Damage to other property caused by defects in this product damages based upon inconvenience loss of use of the product loss of time commercial loss or 2 Any other damages whether incidental consequential or otherwise Some countries may not allow limitations on how long an implied warranty lasts and or do not allow the exclusion or limitation of incidental or consequential damages so the above limitations and exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from place to place NOTE All products returned to Kramer for service must have prior approval This may be obtai
17. r blank covers that can be replaced with wall plates as required Split Grommets Push apart slightly to insert cables Split Brackets Support the split grommet for the pass through cables Power Socket Suitable for a single power socket Adjustable Height Screw For adjusting the height of the inner frame Holes Mounting the Power Socket Assemblies To mount the power socket place the power socket under the frame in its appropriate place and tighten with the two screws supplied Power socket kits come with assembly instructions 9 2 9 3 Installing the Inner Frame To install the inner frame 1 Place the inner frame inside the TBUS 1A enclosure 2 Setthe reguired height using your fingers to bring the inner frame to the desired position screw and tighten it in place using the height adjustment screws supplied with the inner frame Inner frame kits come with assembly instructions Cutting an Opening in the Table To cut an opening in the table 1 Place the included cut out template that is included with your TBUS 1A on the surface of the table exactly where you want to install the TBUS 1A 2 Attach the template to the table with the included screws if using the cut out template 3 Following the inside edge of the template cut a hole in the table surface with a sabre or keyhole saw according to the dimensions shown in Figure 4 not to scale The thickness of the table should be 76 2 mm

Download Pdf Manuals

image

Related Search

Related Contents

PUREE DOUCEUR DE CAROTTE INGREDIENTS  Progress Lighting P3467-20 Installation Guide  Puritan Bennett 840 Ventilator Pocket Guide  Panasonic KX-TG5622 Telephone User Manual  平成6年函審第9号 漁船第十八辨天丸機関損傷事件 言渡年月日 平成6  VS-WRC103LV取扱説明書  Meublés Non ERP et Chambres d`Hôtes  Forno Elettrico Ventilato Manuale d`Uso  D.08.1 Psc - Comune di Milano  Vulcan-Hart K20DL User's Manual  