Home
DVA Network Device Plugins Manual
Contents
1. If the gain exceeds 0 dB the signal is amplified while if the gain is lower than 0 dB the signal is attenuated Freq To set the filter central or cut off frequency Rev 1 0 dBlechnologies 5 5 Compressor Panel Val Channels Comp 30 24 18 D B D 6 l AR 24 30 36 42 A8 54 50 56 72 E 6 A K E 30 24 18 12 6 D 6 LI 18 24 Be Compressor panel shows the compression status for the corresponding audio channel The compression diagram is in green colour The configuration can be performed on the graph by moving the circle with the relevant letter or analytically by inserting the data in the option boxes or else by moving Sliders Threshold identifies the threshold where the compression ratio begins Base is 1 1 Ratio Indicates the conversion ratio between input and output signal Post Gain Applies output gain applied after the compressor Attach Time Set compressor attack time Release Time Set compressor release time Hold time Set compressor hold time Flatten Reset all parameters to default values no compression applied By pass It allows to bypass the compressor Save It allows to save the configuration of one individual channel Load It allows to load a previously saved configuration Send Sends the changed data of each individual channel to the processor This operation is normally carried out by the system in real time while the parameters are being modified Rev 1 0 AVA d
2. see Speaker User manual Group panel Assign the speaker to a Group Equalizer When assigned equalization delay or volume can be modified in the Group Eq window Thermal Limiter becomes yellow when amplifier module starts reducing Audio volume to prevent overheating FW Rev Show revision of currently loaded Firmware Temp indicates PSU temperature in C I Standby enter in standby mode to reduce internal temperature and energy consumption in long O inactivity conditions Button is usually green and becomes red in stand by condition Anyway DVA Network communication remains active and speaker can be reactivated at any time by pressing the key again ATTENTION S If activated standby button will switch PSU module off and will deactivat audio on all 3 output channels Factory Default Allows to reset all settings made via DVA Network software and to restore factory configuration settings VA ATTENTION Speaker must be assigned to a group in order to modify the audio equalization Rev 1 0 dBlechnologies 2 DVA S1518N Sub 18 Bandpass and DVA S1521N Sub 21 Bassreflex 2 1 Compact View 1 1 2 ODVAS15918 _ Eg Syme oo Comm Green indicates that communication between speaker and Control is working In case of communication error the indicator becomes red Eq Sync Green indicates that actual device Eq is synchronized with the Group Eq showed in the DVA Network software Status This indicator
3. shows the device status Green indicates normal operation when it becomes red an error condition is occurring MUTE The device can be muted by selecting the button it turns red when enabled SOLO Allows to listen to only to the selected device Other devices will be automatically muted Light indicators under Speaker Image shows the audio status e Green audio level of the relevant channel exceeds 40dBfs decibel full scale OdBfs maximum power delivered by channel amplifier e Red amplifier delivers maximum power and limiter is active Vu meter bars e left bar green indicates the input signal level in dBu e right bar red indicates the limiter compression level in dB An indicator located above compressor average level becomes red when maximum signal level allowed on preamplifier input is reached 2 2 Expanded View 1 1 1 DVAS1518 Xover Preset FW Rev 0 0 0 FW Rev 0 0 0 BE Es Factory Default L dl Factory Default Woofer Xover Out Panels show advanced parameters for each audio way Woofer Out and Xover Out E Rev 1 0 dBlechnologies Each panel contains e Vu meter bar on the left green channel amplifier output level in dBfs decibel full scale OdBfs maximum power delivered e Vu meter bar on the right red channel limiter compression level in dB e Status or active indicator green channel is ok Red malfunction is detected e MUTE single audio way mute Delay
4. 5 6 Audio signals sourced from outputs 5 and 6 Input A B link lt allows to configure the inputs in stereo and joined modes so that all the filters compressors delays volumes of the two inputs will have the same values If active LINKED button will light up red 5 3 X Over Panel EEN X Overs Equa CCS SSES ea oa ER r o ew P RR r a ca o aI T HER BER CS EE EE CED z Save end This window allows to select for each output a low pass filter and an high pass filter for each output or to create a band pass filter via the combination of both Graphic filters of the individual outputs are identified using the colors shown in the configuration menu The configuration can be performed directly on the graph by moving the relevant square colored cursor with the mouse or analytically by inserting the data in the option boxes Option boxes are composed by the following fields Enabled Activate the filter Type e HPF High pass filter Set to allow only the part of audio signal above the cut off frequency e LPF Low pass filter Set to allow only the part of audio signal below the cut off frequency Slope To select the attenuation slope of the audio signal on the basis of the desired attenuation The higher the signal slope at the same cut off frequency the greater the signal selection Freq Hz To set the passing frequency for the lower frequencies only low pass filter or the higher frequencies only high pas
5. BTechnologies NETWORK 5 6 Preset Panel Name DEFAULT FACTORY PRESET 00 00 00 00 00 00 00 00 00 00 00 00 WE E The Preset List shows all the presets stored on the processor Id It indicates the Identifier number of the preset from 0 to 31 Name It indicates the name of the preset DEFAULT FACTORY PRESET this preset is read only and contains the factory configuration of the processor Local Preset It indicates that the preset was saved via the processor local user interface LCD display and rotary knob Date and time are not reported e User desired name Eg Arena 12 pro system User can associate a desired name up to 16 characters including spaces using the Preset Name box after you have selected the desired configuration number In this case date and current time of the Save operation are displayed Date it shows date and time of saving Not aviable for Local Presets Load Button Load the selected preset from the list Save Button save the actual configuration to a preset in the selected location Delete Button Delete selected preset Rev 1 0 AVA dBi echnologies NETWORK dR TECHNOLOGIES THE SOUND OF EXPERIENCE July 2013 R amp D Dept dB Technologies a brand of A E B Industriale Srl dva_network dbtechnologies aeb com www dbtechnologies com Rev 1 0
6. NT E Status Amp REAR Cardioid Preset FW Rev 0 0 0 K ee oe Kat gr Factory Default Woofer Front Xover Out Panels show advanced parameters for each audio way Main Woofer and Xover Out Rev 1 0 dBlechnologies Each panel contains e Vu meter bar on the left green channel amplifier output level in dBfs decibel full scale OdBfs maximum power delivered e Vu meter bar on the right red channel limiter compression level in dB e Status Amp Front indicator status of the front woofer audio channel green channel is ok Red malfunction is detected e Status Amp Rear indicator status of the Rear woofer audio channel green channel is ok Red malfunction is detected e MUTE single audio way mute Delay Preset panel Select a different audio Delay preset see Speaker User manual Delay is indicated in mS and ranges from 0 to 4 5mS in step of 0 5mS The following formula can be used to align an audio signal v Delay GAPx1000 344 Delay ms in milliseconds GAP distance between speaker and reference point in meters Speed of sound 344 m s Inv Phase performs a phase rotation of 180 respect to the input signal It turns red when phase rotation is active Xover Preset panel Select a different audio preset for Xover see Speaker User manual Woofer Low Pass Cut off Frequency can be selected in step of 5Hz with a slope of 24dB oct An HighPass filter with the same cut of frequen
7. Preset panel Select a different audio Delay preset See Speaker User manual Delay is indicated in mS and ranges from 0 to 4 5mS in step of 0 5mS The following formula can be used to align an audio signal v Delay GAPx1000 344 Delay ms in milliseconds GAP distance between speaker and reference point in meters Speed of sound 344 m s Inv Phase performs a phase rotation of 180 respect to the input signal It turns red when phase rotation is active Xover Preset panel Select a different audio preset for Xover see Speaker User manual Woofer Low Pass Cut off Frequency can be selected in step of 5Hz with a slope of 24dB oct An HighPass filter with the same cut of frequency will be automatically applied to Xover Out Group panel Assign the speaker to a Group Equalizer When assigned equalization delay or volume can be modified in the Group Eq window FW Rev Show revision of currently loaded Firmware Temp indicates PSU temperature in C I Standby enter in standby mode to reduce internal temperature and energy consumption in long O inactivity conditions Button is usually green and becomes red in stand by condition Anyway DVA Network communication remains active and speaker can be reactivated at any time by pressing the key again ATTENTION S If activated standby button will switch PSU module off and will deactivat audio on all 3 output channels Factory Default Allows to reset all settings made via DVA N
8. activat audio on all 3 output channels Factory Default Allows to reset all settings made via DVA Network software and to restore factory configuration settings S ATTENTION Speaker must be assigned to a group in order to modify the audio equalization Rev 1 0 dBlechnologies 4 DVA S30N Sub 2x18 Bassreflex Horn Loaded 4 1 Compact View Comm Green indicates that communication between speaker and Control is working In case of communication error the indicator becomes red Eq Sync Green indicates that actual device Eq is synchronized with the Group Eq showed in the DVA Network software Status This indicator shows the device status Green indicates normal operation when it becomes red an error condition is occurring MUTE The device can be muted by selecting the button it turns red when enabled SOLO Allows to listen to only to the selected device Other devices will be automatically muted Light indicators under Speaker Image shows the audio status for each woofer e Green audio level of the relevant channel exceeds 40dBfs decibel full scale OdBfs maximum power delivered by channel amplifier e Red amplifier delivers maximum power and limiter is active Vu meter bars e left bar green indicates the input signal level in dBu e right bar red indicates the limiter compression level in dB An indicator located above compressor average level becomes red when maximum signal level allowed on pre
9. amplifier input is reached 4 2 Expanded View Woofer 1 Woofer 2 Xover Out Panels show advanced parameters for each audio way Rev 1 0 dBlechnologies Each panel contains e Vu meter bar on the left green channel amplifier output level in dBfs decibel full scale OdBfs maximum power delivered e Vu meter bar on the right red channel limiter compression level in dB e Status or active indicator green channel is ok Red malfunction is detected e MUTE single audio way mute Delay Preset panel Select a different audio Delay preset see Speaker User manual Delay is indicated in mS and ranges from 0 to 4 5mS in step of 0 5mS The following formula can be used to align an audio signal v Delay GAPx1000 344 Delay ms in milliseconds GAP distance between speaker and reference point in meters Speed of sound 344 m s Inv Phase performs a phase rotation of 180 respect to the input signal It turns red when phase rotation is active Xover Preset panel Select a different audio preset for Xover see Speaker User manual Woofer Low Pass Cut off Frequency can be selected in step of 5Hz with a slope of 24dB oct An HighPass filter with the same cut of frequency will be automatically applied to Xover Out Group panel Assign the speaker to a Group Equalizer When assigned equalization delay or volume can be modified in the Group Eq window FW Rev Show revision of currently loaded Firmwa
10. cting the button it turns red when enabled The general mute has the highest priority with respect to the muting of individual channels Input A B Output 1 6 panels each panel indicates the audio status of the corresponding channel e Left side bar green shows the signal level in dBu in dBfs for inputs if Digital Source is selected e Right side bar red indicates the compression level of the compressor in dB 5 2 Expanded View Sa AC26N Detail Input A 8 Source Bere E oe eT HMH HR r DOH U d een H T Li lAnatog In U D UW E si lAnalo Ir A i Ea Gg SOLO MUTE SOO MUTE SOLO MUTE SOLO MUTE SOLO MUTE SOLO MUTE Gain Gain Gam Gain Gain Gain Gain Linked C Processing PFY COMPRESSOR Presets Manage Audio Path fw rev 0 0 0 Inv Phase Inv Phase Left side panel grey hosts the general processor configurations Input A B source This option allows to set the type of input audio signal e Analog In Analog audio signals CA and B inputs e Digital In Digital audio signals AES EBU inputs Rev 1 0 dBlechnologies Digital Out Source This option allows to select the audio source that will be forwarded to the connector AES EBU OUT digital output e Analog In Audio signals sourced from analog inputs Digital In Audio signals sourced from digital inputs Output 1 2 Audio signals sourced from outputs 1 and 2 Output 3 4 Audio signals sourced from outputs 3 and 4 Output
11. cy will be automatically applied to Xover Out Cardioid Preset Gases SC Super Cardioid Rear attenuation range is 135 with respect to the front This i configuration is used when the speakers are positioned laterally to stages whose width is Ke HH between 6 and 14 metres Tue Ge SS C Cardioid heart shaped diagram Rear attenuation range is 180 in line with the Oase front This configuration is to be used if the speaker is placed in front of the stage in a Wes ee central position in this case the low frequencies are practically eliminated on stage 180 MEREN 8 D ree e TIT HC Hypercardioid Rear attenuation range is 120 with respect to the front This is the LJ 429 recommended configuration when the speakers are arranged laterally to stages whose width is over 14 meters Rev 1 0 dBlechnologies Group panel Assign the speaker to a Group Equalizer When assigned equalization delay or volume can be modified in the Group Eq window FW Rev Show revision of currently loaded Firmware Temp indicates PSU temperature in C I Standby enter in standby mode to reduce internal temperature and energy consumption in long O inactivity conditions Button is usually green and becomes red in stand by condition Anyway DVA Network communication remains active and speaker can be reactivated at any time by pressing the key again ATTENTION VA If activated standby button will switch PSU module off and will de
12. dB echnologies NETWORK DEVICE PLUGINS Software version 1 1 Document version 1 0 AVA dBTechnologies NETWORK 1 DVA TS and DVA T12 Line Array Te TUTE 2 1 1 C mpact E 2 Te e tee KEE 2 2 DVA 1518N Sub 18 Bandpass and DVA 1521N Sub 21 Bassreflex cccsssseeeeeesseeeeeeseeees 4 2 1 einer 4 2e lt 8216 Ee 4 3 DVAS2585N Sub 18 15 ele VE 6 3 1 inner 6 ae EPOCO VIEW ee ee ee ee ee ee ee E eee eee 6 4 DVA GON Sub 2x18 Bassreflex Horn Loadedl essen 9 4 1 C mpact EE 9 4 2 Selle e EE 9 5 AC26N Digital Audio Processor EE 11 5 1 MOMMA VI W e e a E A E G E ee 11 32 ee ee 11 E e EE 12 lt PEOP g E 13 55 Compressor PAMS hve si ctcciscextenedecesescisetadechesdecdastatausdestsasetacatads sbvaneideseetaeedeeteseesentsds Asehooddastateusestedes 14 5 6 CSC T 15 Rev 1 0 dBlechnologies 1 DVA T8 and DVA T12 Line Array Module 1 1 Compact View Comm Green indicates that communication between speaker and Control is working In case of communication error the indicator becomes red Eq Sync Green indicates that actual device Eq is synchronized with the Group Eq showed in the DVA Network software Status This indicator shows the device status Green indicates normal operation when it becomes red an error condition is occurring MUTE The device can be muted by selecting the button it turns red when enabled SOLO Allows to listen to only to the selected device O
13. etwork software and to restore factory configuration settings wv ATTENTION Speaker must be assigned to a group in order to modify the audio equalization Rev 1 0 dBlechnologies 3 DVA S2585N Sub 18 15 Cardiod 3 1 Compact View 1 1 5 OVAS2935 B Eg Sync Comm Green indicates that communication between speaker and Control is working In case of communication error the indicator becomes red Eq Sync Green indicates that actual device Eq is synchronized with the Group Eq showed in the DVA Network software Status This indicator shows the device status Green indicates normal operation when it becomes red an error condition is occurring MUTE The device can be muted by selecting the button it turns red when enabled SOLO Allows to listen to only to the selected device Other devices will be automatically muted Light indicators under Speaker Image shows the audio status e Green audio level of the relevant channel exceeds 40dBfs decibel full scale OdBfs maximum power delivered by channel amplifier e Red amplifier delivers maximum power and limiter is active Vu meter bars e left bar green indicates the input signal level in dBu e right bar red indicates the limiter compression level in dB An indicator located above compressor average level becomes red when maximum signal level allowed on preamplifier input is reached 3 2 Expanded View 1 1 6 OVAS 23985 Status Amp FRO
14. re Temp indicates PSU temperature in C I Standby enter in standby mode to reduce internal temperature and energy consumption in long O inactivity conditions Button is usually green and becomes red in stand by condition Anyway DVA Network communication remains active and speaker can be reactivated at any time by pressing the key again ATTENTION S If activated standby button will switch PSU module off and will deactivat audio on all 3 output channels Factory Default Allows to reset all settings made via DVA Network software and to restore factory configuration settings YA ATTENTION Speaker must be assigned to a group in order to modify the audio equalization Rev 1 0 dBlechnologies 5 AC26N Digital Audio Processor 5 1 Compact View OUTDT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 24 24 24 24 24 12 12 12 12 12 0 0 0 ls a 12 12 12 C 12 S 12 24 24 24 g 24 24 36 36 24 12 g 12 24 36 lt 36 lt 36 Comm Green indicates that communication between speaker and Control is working In case of communication error the indicator becomes red Eq Sync Green indicates that actual device Eq is synchronized with the Group Eq showed in the DVA Network software Status This indicator shows the device status Green indicates normal operation when it becomes red an error condition is occurring MUTE The device can be muted by sele
15. s filter Rev 1 0 dBlechnologies 5 4 PEQ Panel 6a Channels Equalizers a m e oe oe ee oe _ g mm mm em m vm vm vm Gm vm mmm g ms mmm emm _ mmm mmm vm mmm a a m mmm emm mmm mmm mmm mmm mmm gem _ mmm mm mmm mmm mmm m am an mmm mmm emm PEQ panel allows to equalize each single Input or Output channel correcting one or more frequencies that have to be reduced or increased The graphs shows a red line that represent the resultant of all activated filters Each single filter Frequency response will be showed in white and will become Green when the corresponding filter is selected Filter parameters can be edited by moving the round icon on the graph or analytically by inserting the data in the option boxes Enabled Select the relevant dedicated box to activate the filter development Type To configure the kind of equalizer e PEQ Peaking equalizer Correct only a defined range of frequencies e SHF High shelf Equalizer All frequencies pass but frequencies above the selected cut off frequency are increased or attenuated by the given gain e SHF Low shelf Equalizer All frequencies pass but frequencies below the selected cut off frequency are increased or attenuated by the given gain Bw only available with PEQ filters It defines the range of frequencies where the filter work the greater the value of Bw the narrower is the frequencies range Gain It set the gain of the selected frequencies
16. ther devices will be automatically muted Light indicators under Speaker Image shows status of each audio way Midrange tweeter and woofer e Green audio level of the relevant channel exceeds 40dBfs decibel full scale OdBfs maximum power delivered by channel amplifier e Red amplifier delivers maximum power and limiter is active Vu meter bars e left bar green indicates the input signal level in dBu e right bar red indicates the limiter compression level in dB average of the 3 audio ways An indicator located above compressor average level becomes red when maximum signal level allowed on preamplifier input is reached 1 2 Expanded View 1 1 1 DVATS 20 20 40 Terg Bh E i 22 40 LZ ie LZ ie x Status Pie sto Fie T Group Preset Thermal Limiter FW Pew 0 0 0 ferro Temp e A Factory Default HD FW Rev 0 0 0 Tove DS FA Factory Default MF HF LF Panels show advanced parameters for each audio way Midrange Tweeter and Woofer Rev 1 0 dBlechnologies Each panel contains e Vu meter bar on the left green channel amplifier output level in dBfs decibel full scale OdBfs maximum power delivered Vu meter bar on the right red channel limiter compression level in dB amplifier temperature indicated in C Status indicator green channel is ok Red malfunction is detected MUTE single audio way mute Preset panel Select a different audio preset
Download Pdf Manuals
Related Search
Related Contents
PAC-YW51BAC 取扱説明書 Ikelite S95 User's Manual カタログ PM12PTO - TekSupply Gebruiksaanwijzing 2 User manual 15 Notice d'utilisation 28 Oven miroSOUND PCM20 radio AN038 Getting Started with the KXTJ2 Copyright © All rights reserved.
Failed to retrieve file