1. 20 C 40 C Direct air convection 380 x 200x 190mm Weight 8Kg 2008 9 19 1 4 PHOTOMETRIC DATA WHITE AMBER 3338 900 410 166 LUX 1261 361 155 90 62 LUX OV mt 100 10Distance m 2 4 6 10Distance m 3 2 1 K 1 2 3 WHITE AMBER 4795 1270 10Distance m 1 5 SAFETY WARNING IMPORTANT ALWAYS READ THEUSER MANUAL BEFORE OPERATION PLEASE CONFIRM THAT THE POWER SUPPLY STATED ON THE PRODUCT IS THE SAME AS THE MAINS POWER SUPPLYIN YOUR AREA e This product must be installed by a qualified professional e Always operate the equipment as described in the user manual eA minimum distance of 0 5m must be maintained between the equipment and combustible surface e The product must always be placedin a well ventilated area e Always make sure thatthe equipmentis installed securely e DO NOT stand close to the equipment and stare directly into the LED light source e Always disconnectthe power supply before attempting and maintenance e Always make sure that the supporting structure is solid and can support the combined weight ofthe products e The earth wire must always be connected to the ground e Do not touchthe power cablesif your hands are wet ATTENTION AATTENTIONA e This product leftthe place ofmanufactu
2. ITEM BRACKET PLASTIC BASE COVER DISPLAY BOARD DRIVER BOARD POWER SUPPLY POWER SUPPLY COVER METAL BASE LEDBOARD LENS COMPLETE SET 10 PLASTIC UPPER COVER Version 1 0 5 APPENDIX 14 2008 9 19
3. WA D STUDIO 1 or STUDIO 2 3 DISPLAY PANEL OPERATION 8 2008 9 19 3 7 IDADDRESS MENU 1D gt Address 001 066 ID e Enter the D mode to setthe IDADDRESS 3 8 SPECIAL SETTINGS MODE SETTING Upload gt Password gt Sending End RESET Parameter gt Password gt kkk p Resetting ID ON OFF ON OFF SETTING e Select Upload to upload the custom programs fromthe current MASTER unit to the SLAVE units e In orderto activate the upload function the password mustbe entered e Password is the same as the main access password e When uploading the MASTER and SLAVE units willbe full on e f an error occurs when uploading the MASTER and or SLAVE units will display AMBER e On successful uploading of the custom programs the MASTER and SLAVE units will display WHITE e In order toreset custom modesto default valuesselect PESET Parameter e Enter D ON OFF in orderto allow disallow ID address function from the DMX512 controller 3 9 ACTIVATE THE PASSWORD MENU KEYLOCK gt ON OFF KEYLOCK e Enter the KEYLOCK mode to selectwhether the access password is onor off e In order toenter access passwordit is necessaryto firstpress SET e Access password is UP DOWN UP DOWN 3 10 WHITESSETTING MODE gt _CALIB_ gt WHITE1 White gt 0 255 WHITE 2 Amber 0 255 WHITE 8 CALIB e Enter the CALIB
4. to select white color of different color temperature e There are 8 pre programmed White colors can be edited by using Whitel 8 Amber 3 DISPLAY PANEL OPERATION 9 2008 9 19 A USING ADMX512 CONTROLLER 4 1 BASICADDRESSING e Connect all of the unitsin series using standard DMX512 signal cable or the IP65 rated cable provided e Set the DMX512 address in the DMX menu e It is possible to have the same DMX address or independent addresses for each fixture 4 2 CHANNEL ASSIGNMENT e Note This product have four DMX512 channel configuration WA WA D1 STUDIO 1 and STUDIO 2 WA CHANNEL VALUE FUNCTION 1 0 lt gt 255 WHITE 2 0 lt gt 255 AMBER WA D CHANNEL VALUE FUNCTION 1 0 lt gt 255 MASTER DIMMER 2 0 lt gt 255 WHITE 3 0 lt gt 255 AMBER STUDIO 1 CHANNEL VALUE FUNCTION 1 0 lt gt 255 MASTER DIMMER 2 0 lt gt 255 SAME AS STUDIO 2 CH4 4 USINGA DMX512CONTROLLER 10 2008 9 19 STUDIO 2 CHANNEL VALUE FUNCTION 4 MASTER DIMMER 0 lt gt 255 2 WHITE 0 lt gt 255 AMBER 3 0 lt gt 255 DIFFERENT WHITES 0 lt gt 10 NO FUNCTION 11 lt gt 40 WHITE 1 2800K 41 lt gt 70 WHITE 2 3000K 71 lt gt 100 WHITE 3 3200K 4 101 lt gt 130 WHITE 4 3400K 131 lt gt 160 WHITE 5 4200K 161 lt gt 190 WHITE 6 4900K 191 lt gt 220 WHITE 7 5600K 221 lt gt 255 WHITE 8 5900K STROBE 5 0 lt gt 9 NO FUN
5. 255 Amber 0 255 Strobe gt 0 20 Dimmer 0 255 DMX Address 001 512 RUN MODE gt DMX SLAVE PERSONALITY gt WA WA D STUDIO 1 STUDIO 2 ID gt Address 001 066 SETTING gt Upload Password gt _ Sending gt End RESET Parameter gt Password kkk gt Resetting ID ON OFF gt ON OFF KEYLOCK gt ON OFF CALIB gt WHITE1 White gt 0 255 WHITE2 Amber 0 255 WHITES 3 DISPLAY PANEL OPERATION 7 2008 9 19 3 3 EDIT STATIC COLOUR MODE gt STATICCOLOR gt White gt 0 255 Amber 0 255 Strobe 0 20 Dimmer gt 0 255 STATIC COLOUR e Combine White Amber and Dimmer to create whites with different color temperature e Set the value ofthe Strobe 0 20Hz 3 4 DMX512 SETTINGS MENU gt DMX gt Address 001 512 DMX e Enter the DMX mode to setthe DUXADDRESS 3 5 RUN MODE MENU gt RUNMODE gt DMX SLAVE RUN MODE e Enter the RUN MODE mode to set working mode e DMX mode is forusing the DMX512 controller to controlthe fixtures e SLAVE mode isfor Master Slave operation Note When fixtures are under Auto program operation the RUN MODE does no works 3 6 PERSONALITY MODE PERSONALITY gt WA WA D STUDIO 1 STUDIO 2 PERSONALITY e Enter the PERSONALITY mode to select DMX mode WA
6. address inthe range from 001 to 512 may be used e Each DMX address may carry upto 66 separate ID addresses e ID should beset inthe menu on each unit in ascending values i e 1 2 3 e ID On should beset inthe Settings menu on eachunit e ID addresses are accessible from CH6 on the DMX512 controller 2 INSTALLATION 5 2008 9 19 Example DMX Adar 1 DMX Adar 1 DMX Addr 1 DMX Adar 7 DMX Adar 7 DMX Adar 7 ID Addr 1 1D Addr 2 ID Addr 3 1D Adar 1 1D Adar 2 ID Addr 3 DMX512 CONTROLER The figure above shows a simple DMX layout which has usedthree units ateach DMX address The three units have different ID addresses which allows the user to collectively controlthe whole group of units atthat DMX address by setting CH6 to 0 orto control each unitindependently by first selecting the DMX address and then by using Ch6 to locatethe target ID address 2 INSTALLATION 6 2008 9 19 3 DISPLAY PANEL OPERATION 3 1 BASIC The LED fixtureis mounted witha LCD display and 4 control buttons MODE scroll through the main menu orreturn to the main menu SET enter the currently selected menu or confirm the current function value UP scroll UP through the menulist or increase O O O O the value of the currentfunction DOWN scroll DOWN through the menu list or decrease MODE SET YE DOWN the value of the current function 3 2 MENU MODE STATICCOLOR gt White _ 0
7. 6 independentID addresses e An IDaddress of Owill activate alllD address locations 4 USINGA DMX512CONTROLLER 12 2008 9 19 5 APPENDIX 5 1 5 APPENDIX SITUATION No display LCD MODULE on but nocontrol from display Display normal but no response from buttons Display normal but no response from buttons Color mixing uneven with splash TROUBLE SHOOTING CAUSE 1 No powerinput 2 Power connectionerror 3 Display damaged 4 Display boardIC error or power input connection error or two boardconnection error 5 Contrast decay 1 Main PCBreverse install 2 Main PCB damaged 1 Buttons damaged 2 Main PCBdamaged 1 Signal Cable error 2 Signal conncetionerror 3 The inputsignal IC damaged4 DMX address error 1 LED notjoining well 2 Lens notinstalling well ACTION 1 Check power supply 2 Check powerconnection 3 Replace display 4 Check the IC and allthe connections 5 Adjustthe LCD contrast 1 CheckMain PCBinstallation and quality 1 Replace buttons 2 Replace MainPCB 1 Check allsignal Cables 2 Check allsignal conncetions 3 Check theinput signal IC 4 Check DMX address 1 Check LEDsjoining 2 Check lens installing LEDs of thesame color are notlit 1 LED damaged 2 LED damagedor Main PCB 1 Replace LEDs 2 Replace damagedLED or MainPCB Manual and program can not save 1 Saving IC damaged 13 1 Replace saving IC 2008 9 19 5 2 MAINTENANCE
8. CONNECTIONS 220V 35 units may be connected in series 120V 15units may be connected in series Note As thisfixture s DMX signal cable connection is Parallel connection soif over 20 units to be connected then a DMX signal amplifieris needed 2 INSTALLATION 4 2008 9 19 2 3 SETTING UP WITHADMX512 GONTROLLER 2 3 1 DMX512 ADDRESSING WITHOUT ID ADDRESSING STUDIO 2 MODE e Connect the DMX512controller to theunits in series e Each unithas 6 DMX channels so the DMX Addresses should increase by increments of 6 e g 1 7 13 19 eThe ID address has not beenset so therefore when usingthe controller CH8 must be inactive CH6 0 elt is also possible to deactivate ID address selecting ID OFF from the Settings menu on the fixture e Each DMX Address may beused as many times as required e Any DMX address inthe range from 001 to 512 may be used Example DMX Adar 1 DMX Adar 7 DMX Adar 13 DMX512 CONTROLLER The figure above shows a simple DMX512 layout with thestarting address ofthe first unit set at 1 with the second set at 7 and so on Note thatwhen usedin this way the CH6 ID function must be inactive CH6 0 2 3 2 DMX512 ADDRESSING WITH ID ADDRESS STUDIO 2 MODE e Connect the DMX512 controller to the units in series e Each unithas 6 DMX channels so the DMX Addresses should increase by increments of 6 e g 1 7 13 19 e Each DMX Address may beused as many times as required e Any DMX
9. CTION 10 lt gt 255 1 20Hz ID ADDRESS 0 lt gt 9 D1 1D66 10 lt gt 19 D1 20 lt gt 29 D2 30 lt gt 39 D3 40 lt gt 49 D4 50 lt gt 59 D5 60 lt gt 69 D6 70 lt gt 79 D7 80 lt gt 89 D8 90 lt gt 99 D9 100 lt gt 109 D10 110 lt gt 119 D11 6 120 lt gt 129 D12 130 lt gt 139 D13 140 lt gt 149 D14 150 lt gt 159 D15 160 lt gt 169 ID16 170 lt gt 179 D17 180 lt gt 189 D18 190 lt gt 199 D19 200 lt gt 209 D20 210 D21 255 1D66 4 USINGA DMX512CONTROLLER 11 2008 9 19 4 3 BASIC INSTRUCTIONS FOR DMX512 OPERATION STUDIO 2 MASTER DIMMER e CH1 controls the intensity of the currently projected color e When the slider is at the highest position 255 the intensity ofthe outputis the maximum WHITE 8 AMBER SELECTION e CH2 and CH3 control the intensity ratio of eachof the WHITE 8 AMBER LEDs When the slideris atthe highest position 255 the intensity of the color is the maximum O CH2 and CH3 can be combined together to create whites with different color temperature STROBE e CH 5controls the strobe of CH1 to CH4 e CH5 has priority over CH2 CH3 8 CH4 DIFFERENT WHITES e Ch4 allow user to select 8 whites with different color temperature e The 8whites are take fromthe CALIBI on Display panel ID ADDRESS SELECTION e CH6 is usedto select thetarget ID address e Each independent DMX address may have upto 6
10. LEDbloc USER MANUAL ABLE OF CONTENTS PART 1 PRODUCT GENERAL lt lt lt w lt tiit tun nuv esaduatann ia lacada da adn 1 1 1 PRODUCT INTRODUCTION 00ccccccccccceccecensessecensensecensenseteeses 1 1 2 PRODUGT FEATURES cual it tie 1 1 3 TECHNICAL SPECIFICATIONS cccccccceccccececcecensecenserensersesente 2 1 4 PHOTOMETRIC DATA vicki oo i aa das ake 3 1 5 SAFETY WARNING cccccccccecececececeensetenecenensneeeesenesetenesentnsetes 3 PART 221INS TALLATION cota tds asa 4 2 1 MOUN FIN Gite A oia 4 2 2 POWER CONNECTION b 2sescceescevcsccrdeneegesteed cies a e a a eee 4 2 3 SETTING UP WITH A DMX512 CONTROLLER 0 cccccccecececeeees 5 2 3 1 DMX512 ADDRESSING WITHOUT ID ADDRESSING 5 2 3 2 DMX512 ADDRESSING WITH ID ADDRESS cscccscscscscscscscssesesesesesesessessvssees 5 PART 3 DISPLAY PANEL OPERATION c ccceeeceeneceeneceeseuees 7 SP BASIC ita S tea aataid TA 7 A O t 7 3 3 EDIT STATIC COLOUR moih e e a a a a ai a ei 8 3 4 DMX512 SETTINGS cairn a a A a a N ae eaa 8 IO ROUN MOD E Kris a e tl E 8 3 6 PERSO NA ia La A A E aE Bede 8 3 T AIDADDRES Susini iia aia tds sol ae 9 3 8 SPECIAE SETTINGS 000 li 9 3 9 A CTIVATE THE PASSWORD cooococcccccnncocononcononcnnnnnnnonnnonnnonnnnnnnonos 9 3 10 WHITES SETHING rei nutavad taal kae legal vea E t ta 9 PART 4 USING A DMX512 CONTROLLER nnnn
11. annannnana 10 4 1 BASICG ADDRESSING ds 10 4 2 CHANNEL ASSIGNMENT ccccccccccncccecececeneenensetenscenetnseseneneas 10 4 3 BASIC INSTRUCTIONS FOR DMX512 OPERATION 12 PART 5 APPENDIX S cui A ied 13 5 1 TROUBLE SHOOTING ccsccccsccscctensotssecsesscsnsccssessvessensessevesesceess 13 8 2 MAIN TENANCE coa Ae a led ae Ss 14 PRODUCT GENERAL 1 1 PRODUCT INTRODUCTION This product is designed for indoor or outdoor use Suitable applications include wash or effect lighting for architectural stage or nightclub applications This product can also be installed for use in signage and advertising using the dynamic functions available with DMX512 control Direct input of DMX512 signal allows the units to be controlled from any DMX512 controller This product can be operated as a single unit or in multiple units for large applications 1 2 PRODUGT FEATURES LED FIXTURE Dimmer0 100 Strobe IP65 protection rating LCD display Display control lock out DirectDMX512 input Independent IDaddress Lightweight aluminium casing Different white colors setting 1 PRODUCT GENERAL 1 2008 9 19 1 3 TECHNICAL SPECIFICATIONS LED MODULE 1 PRODUCT GENERAL LED MODULE Voltage 100 240V 50 60Hz Rated Power IP 80W IP65 protection rating LED Unit 54pcs 42 x White 12x Amber Output LED 1W Environment Temperature Cooling Dimensions
12. re in perfectcondition In orderto maintain this condition and for safe operation the user mustalways followthe instructions and safety warnings described in this user manual e Avoid shaking or strong impactsto any partof the equipment e Make sure thatall parts ofthe equipment are kept clean andfree of dust e Always make sure thatthe power connections are connected correctand secure elf thereis any malfunction of the equipment contact your distributor immediately e When transferring the product it is advisable to use the original packaging in which the productleft the factory e Shields lenses orultraviolet screens shallbe changed ifthey have become damaged to such an extent that their effectivenessis impaired e The lamp LED shall be changed if ithas become damaged or thermally deformed 1 PRODUCT GENERAL 3 2008 9 19 2 INSTALLATION 2 1 MOUNTING HANGING The LEDbloc can be mounted in a hanging position using the supporting bracket The bracket should be secured to the mounting truss or structure using a standard mounting clamp Please note that when hanging the unit a safety cable should also be used UPRIGHT The LEDbloc can be mounted in an upright or sitting position usingthe supporting brackets The LED MODULE can be mountedat any angle and in any position It ispossible to further adjust the angle of the LED MODULE using thetwo adjustment knobslocated on theside of the fixture 2 2 POWER
Download Pdf Manuals
Related Search
Related Contents
Acerca de Windows NT Workstation 4.0, aplicaciones y software de Delft3D-TIDE User Manual ASUS (M6NE/SXGA) Barebone 20150306_Fiche descriptive concours CHED Sauvadet 2015 MCC Freescale - MPC8323E-RDB - MPC8323E-RDB Reference Selez. - Konica Minolta Sky Connect Series Installation Manual Avanti CF61 Freezer User Manual FICHA TECNICA Rev.1: Julio 2008 Página 1 de 2 Medisana 76156 digital body thermometer Copyright © All rights reserved.
Failed to retrieve file