1. 60S 14 360 scanning 360 scanning at one preset position Dome speed is Grade1 Grade 2 Grade 64 from slow to fast 6 5 View Preset Position 1 Press Clear key to clear the number in the data area 2 Input the address of the dome in the Data area press down lt CAM gt key and show it in DATA area 3 Input the preset position you would like to view Example View preset position No 5 MON CAM DATA Displays the Preset Position lt A 01 0001 0000 Number 1 128 4 Press CALL key The dome will move to the Preset Position No A After pressing CALL key dome camera will nun to the preset position you Would like to view at Grade 64 280 S speed 6 6 Preset Position Parameter Set for the Dome RANCENT protocol has this function 15 Press MPX or Auto key until LCD displays 1 speed dome Setup Number 0000 Press Clear key to delete previous data Input required address code XXXX 1 1024 for control Press Enter key for confirmation Press Enter key into preset position set of dome camera A The below menu is submenu Press FUN into submenu after entering this main menu 14 6 6 1 Preset Position Speed and Dwell Time Set Dome Camera has the capacity to set up to 128 preset positions through the keyboard It can set a running speed at each preset position from 0 4 s to 280 s 1 64 grades and dwell time from 1 60 seconds Note can rotate at low speeds and at fast spe
2. Group Group Number 0 Number 1 8 4 Input a Group number using the number keys press Enter key the keyboard displays Add 5 Input desired Pattern Tour for the Group You can set up to 16 Preset Positions in one Group Example Desired pattern tour of 6 Preset Positions The sequence is Preset Position No 1 2 3 4 5 6 The keyboard displays Add 1 gt 2 gt 3 gt 4 gt 5 gt 2 gt 6 Press Enter key to confirm Pattern Tour Note When completed Press SHIFT MON to close and exit To Start the Scan In the Main Menu enter the Group Number and Press SCAN gt This dome can set 8 cruise groups with a Max of 16 cruise points Each group 1 128 points at any preset position Set the preset position at each of the cruise groups Dwell time at each preset position can be customized at a different time 1 60 seconds The speed to each preset position can be different 1 64 grades Default cruise group will auto scan by starting at preset position point No 1 to preset position point No 16 V VVoV 16 16 Pattern tours Layout different preset position for Dome Camera as one group make the camera scan as set route in advance The running speed and dwell time of each preset position can be programmed Two pattern tours styles can be used A To and from Scanning ape A arras Make an auto circle scanning by points Press EXIT key and exit to default status of the keyboard Input cruise Number adjust key SCAN into t
3. Press Enter key for confirmation a blank screen will appear Press any key except the lt EXIT gt key the relative name will display on the screen Press lt EXIT gt to leave the testing status and return to the main Menu 3 2 7 Max Slave Control Number Set 10 Press MPX or Auto key until LCD displays 7 MAX 16 SLAVE ID XX gt Default Setting Input new ID XX Input number 00 16 Press Enter key for confirmation If the keyboard is set as 01 02 16 it will be considered as the total slave control keyboard quantity separately 3 2 8 Max Alarm Set 1 Press MPX or Auto key until LCD displays 8 MAX 239 ALARM ID XX Default setting Input new ID XX Input number the biggest alarm input terminal number is 239 Press Enter key for confirmation System Keyboard Keyboard Overview The keyboard is used for controlling the intelligent dome The keyboard is the main device between operator and device in the monitoring system It can be regarded as the main control keyboard and as the vice control keyboard 1 Liquid Crystal Display The LCD display board is regarded as interface between operator and device It is direct convenient easy to follow and conveys large amounts of information 2 Proportion Joystick Options PTZ control joystick and PT control joystick Use this joystick to operate high speed dome It is easy to use with good handling and flexible maneuvering 3 The
4. key until LCD displays 7 MAX 16 SLAVE ID XX Default Setting Input new ID XX Input number 00 16 Press Enter key for confirmation A Ifthe keyboard is set as 01 02 16 it will be considered as the totalVice control keyboard quantity separately 5 1 8 Max Alarm Set 1 Press MPX or Auto key until LCD displays 8 MAX 239 ALARM ID XX Default setting Input new ID XX Input number the biggest alarm input terminal number is 239 Press Enter key for confirmation A Ifthe keyboard is set as 000 001 002 239 the total relative quantity for Alarm input terminal will be in operation 10 When there are two or more than two keyboards in one system please use the main control keyboard to set the total desired vice keyboard quantity should be set 16 vice control keyboard at most If the vice keyboard quantity are not set the vice keyboards will not control camera dome The number desired to input should be more than or equal to the total actual vice control keyboard quantity 11 You should set the total alarm input terminal quantity for alarm dome camera if such dome camera is adopted The number desired to input should be more than or equal to the total actual alarm input terminal quantity One dome camera has 4 alarm input e 59 alarm dome camera can be connected with the keyboard at most VI Intelligent Keyboard Operation The startup interface is general operation Menu after the keyboard is connected to
5. lock function of the keyboard can prevent unauthorized users to operate the keyboard 4 Provide RS485 control output signal and also offer the standard RS232 control signal Il Intelligent Keyboard Technical Parameters 1 Communication baud rate 1200bps 2400bps 4800bps 9600bps 2 Protocol RANCENT PELCO_D PELCO_P VntPD 3 Data Format N 8 1 4 Power input AC DC 9V 12V 5 Max controlled dome camera 1024 2 6 Power 5W Intelligent Keyboard Drawing 3 1 Intelligent Keyboard Connection Insert one end of keyboard data line into keyboard A2 B2 on the right of its back panel 1 Proportion Joystick The speed of the joystick is a direct ratio to the running speed of the dome camera 2 The keyboard can set up to 1024 sole addresses However it does not control 1024 dome cameras directly The strength and weakness of the RS485 control signal determines the speed dome quantity It can control up to 1024 VPTZ dome cameras through signal compensation devices The RS485 can control 32 dome cameras at most if it has no signal compensation 3 2 Keyboard Connection with Dome Camera RS48 RS48 RSA85 RS485 e RS485 RS485 RS485 dome camera dome camera dome camera When dome camera is furthest away from the control keyboard Please set switch of matching resistance as ON status 3 R is on behalf of matching resistance The farthest matching resistance in order to minimize RS485 bus reflection and disturbance The 8fbit of SW3
6. see below for reference Operating Key Function Enter Enter Login Exit function MPX Dome MENU cursor up Auto Dome MENU cursor down Call Dome MENU cursor right Scan Dome MENU cursor left Pan_A Select DVR Keyboard function Menu exit to upper MENU dome camera MENU set should consult Dome Camera manual VII Auxiliary Function Set A The auxiliary function is used with other RANCENT products It is not used with the Dome camera 7 1 Wash Brush Set 17 Press MPX or Auto key until LCD display as below 3 Wash Number 0001 OFF Set Wash Brush open by pressing down SHIFT MON key Set Wash Brush close by pressing down SHIFT CAM key 7 2 Heating Set 18 Press MPX or Auto key until LCD display as below 4 Warm Number 0001 OFF Set Heating open by pressing down SHIFT MON key Set Heating close by pressing down SHIFT CAM key 7 3 Auxiliary Switch 1 Set Press MPX or Auto key until LCD display as below 5 Auxiliary 1 Number 0001 OFF Set Auxiliary Switch 1 open by pressing down SHIFT MON key Set Auxiliary Switch 1 close by pressing down SHIFT CAM key 17 This Function is used for the frontal terminal device with the wash brush function only 18 The fan and heater in the speed dome camera is always under auto temperature control status This function will auto start when the tempera
7. shows ON status which means the BUS matching resistance has been connected IV Function Key gt Joystick Control Dome Camera running Up down Left Right Left up Left down Right up right down camera lens zoom in and zoom out Keyboard joystick can t control Dome Camera lens zoom in and zoom out Dome Camera Selection and Auto scanning Control Data Input Clear and Confirmation Menu Turning Exit and Preset Position Set Dome Camera Lens Control and Keyboard Lock and Unlock LCD Data Display VVVV WV Function Key Explanation is As Below Other key such as GRP SEQ NEXT AREA DVR is designed for other RANCENT terminal device KEY Function 0 9 Data key Clear Clear the inputted number on the DATA display area MON matrix monitor selection CAM Dome Camera address selection Enable Alarm open set4 Shift Enable Alarm close set Shift Clear Clear Alarm Pan_A Set the start point of dome camera auto scanning Pan_B Set the end point of dome camera auto scanning Auto Finish Dome Camera auto action select Menu items down Shift Auto Adjust Dome Camera pattern tour function Scan Startup scanning group model NO 1 Shift Scan Startup scanning group model NO 2 Call Call Dome Camera preset position function Shift Call Set Dome Camera preset position function MPX Clear Dome Camera preset position function select Menu items up SHIFT EXIT Enter keyboard
8. the power supply LCD displays as follows MON CAM DATA 01 0001 0000 6 1 Keyboard Communication Address Set Input any number within 1 1024 Dome Camera address in DATA area Press lt CAM gt key The relative number will display on CAM area 6 2 Keyboard Control for Dome Camera When Operating keyboard joystick in different directions Dome Camera will do relative movement The joystick excursion scope from center is direct ratio to running speed of Dome Camera 0 4 S 280 S When the DATA column does not show 0 the DATA column displays the Address of the dome camera When the DATA column shows 0 the CAM column displays the address Of the dome camera Take RANCENT protocol for example to operate Dome Camera 6 3 Auto Scanning 2 Points Scanning 360 Scanning A 2 Points Scanning 2 The operator can also run a simple point to point scan also called back and forth scanning To do this set Preset Point A first at the same time set the dwell time at Point A and then set Present Point B at the same time set the dwell time at Point B Finally execute an outer command to scan between points and B 12 2 points scanning It means scanning between two points The speed is Grade1 Grade 2 Grade64 from slow to fast Press Clear key on the keyboard DATA area to delete value on DATA column 1 To set Point A Move the joystick to the desired position 2 In the Main
9. 010010 O AC220V hel R 1 pe j 1 M h k for la 6 ol ae AN a 77 y POWER 1N Le alg 6 4 Is a h 20 ha Jos 32 64 RS232Communicat ion Vid A di ideo Audio Video Audio Output Input B2 A2 GNDB1A1 00 000 AREA MON CAM DATA o 00 0 0001 0000 COM ALARM LINK ACK10 100M deis Ti pvr P H 7 8 9 Enabll ack List 5 4 5 6 fus to nea Bute call GRP SEQ Next 1 2 3 CO Zoom Zoom Shif Logil Clea Ente 5 nl A i Exit y o AREA MON can 2 3 2 RS485 Communication Dome connecting wire are diagramed below for reference RS485A ND KEY S485A Connect Dome O O O O O O O O O O O O O 2 3 3 RS232 Communication RS232 connect PC Alarm equipment etc Note When keyboard controler control matrix system RS232 Port must be taken out 2 4 Alarm out connect connecting wire are diagramed below for reference RS485A ND KEY S485B S485A ND PTZ S485B S485A ND SYS RS485B auxi gt Two alarm AUX2 gt lt S output QA 7ROR7 FA O O O O O O O O O O O O O 2 5 Video matrix connect audio matrix connecting wire are diagramed below for reference O RS485A O GND KEY O RS485B O RS485A O GND PTZ O RS485B O RS485A o GND SYS Connect Audio O RS485B matrix AUX1 O O AUX2 O VERTE BIT 1 BIT 2 Protocol OFF OFF PELCO_D ON OFF PELCO_P OFF ON KALATE ON ON RANCENT System setting 3 1 Set p
10. Menu Zoom in Press lt ZOOM in gt key joystick make a veer rotation Zoom out Press lt ZOOM out gt key joystick make a retrorse rotation Focusing Far Press lt FOCUS far gt key Focusing Near Press lt FOCUS near gt key IRIS open Press lt IRIS open gt key IRIS close press lt iris close gt key dome from the control center should be set as its V Keyboard Parameters Setting The keyboard intelligent keyboard baud rate and communication protocol should Be consistent with that of the dome camera 5 1 Keyboard Parameters Set Press SHIFT EXIT key enter Keyboard main Menu Then Press MPX or Auto key until LCD displays 2 Keyboard setup Press Enter key into keyboard set up Menu Press MPX or Auto key to enter the subMenu Press EXIT key to exit to the main Menu 5 1 1 Keyboard ID No Set Press Enter key on keyboard screen Keyboard setup until LCD displays 1 Cur Keyboard ID XX gt Current keyboard ID No 0 Mast 1 16 Slave XX Input New ID No Input the number 0 16 press Enter key for confirmation New ID will be in effect immediately ID 00 Main Control Keyboards ID 1 16 Vice Control Keyboard The default keyboard ID number is No 00 This is also the ID number for the Dome camera Verify the keyboard ID if the ID No is not set correctly you will Not be able to control the dome camera 5 Keyboard ID is used to set multi controlling keybo
11. Menu enter a dwell time for PointA Example If Dwell time is 2 seconds the keyboard displays MON CAM DATA 01 0001 0000 3 Press PAN A key 4 To set Point B move the joystick to the desired position 5 In the Main Menu enter a Dwell time for Point B 6 Input the grade Speed 1 64 and Press AUTO key This will start up 2 points Scan B 360 Scanning The Operator can also start an auto cruise scan This scan will rotate 360 from the desired position Press Clear key on the keyboard DATA area to delete value on DATA column 1 In the Main Menu input desired cruise group No Example Desired Group No is 4 the keyboard displays MON CAM DATA 01 0001 0000 2 Press Shift Scan key to place PTZ into cruise scanning OR 1 Move the joystick to desired position 2 Input the running speed 1 64 and then input Shift AUTO key Shake the keyboard joystick to stop auto scanning 6 4 Set Preset Position 1 Press Clear key to clear the number in the data area 2 Enter the Preset Position Number you wish to set You can set up to 128 Preset Positions Ex Set Preset Position No 1 the keyboard displays MON CAM DATA Displays the Preset 01 0001 0000 Position Number 1 128 3 Adjust the camera to the desired position including location camera zoom focus and iris 4 Press Shift Call key for final confirmation 13 Dwelling time Can set dwelling time at one preset position 18 25
12. RC MT2000 MATRIX SWITCHER CONTROLLER USER MANUAL Rancent Technologies Ltd 10 F Hong Kong Trade Centre 161 Des Voeux Road Centrl Hong Kong Tel 852 2816 7037 Fax 852 2855 8158 Connection and Setup Safety Attention Notes Please read the instructions thoroughly before installing or operating the unit Please do not put the machine on an unstable table or mounting bracket Please prevent all liquids or other contaminating material from entering into the matrix housing When connecting to the power source please follow all electric safety standards and only use the power supply designated for this device The matrix s RS 485 and video signal uses TVS technology to protect it from strong electric surges This technology prevents damage to the device resulting from impulse signals such as lightning strikes or surges under 500W power Allow for enough distance between the RS 485 and video signals and high voltage equipment or cables during the transmission process Please do not power the unit until all connections are secure and installation is complete When the machine is not operating properly do not casually repair it Refer to the instructions for information about how to service or repair your matrix Please protect the unit against extremes of vibration pressure or dampness while transporting unit Damage can occur from improperly packaging the unit while shipping Please only install the indoor envir
13. ards when a series of Cameras are required to be controlled A group of speed domes can be supported by one main control keyboard and 16 vice control keyboards 6 Main control keyboard Its ID is 00 It enjoys priority when several keyboards are in control Only one of several keyboards can be set as main control keyboard ID must be sole not repeated 7 Vice control keyboard ID is to be 01 16 keyboard 5 1 2 Keyboard Baud Rate Set Press MPX or Auto key until LCD displays 2 Cur Baud Rate XXXX Current baud rate 12 24 48 9600 XXXX Input new baud rate Optional baud rate 9600 4800 2400 and 1200 Default baud rate 9600bps Input your required baud rate in DATA area and press Enter key for confirmation New baud rate is in effect immediately 5 1 3 Key press Sound Set Press MPX or Auto key until LCD displays Displays current set Your select Select Sound preference Press lt SHIFT MON gt key showing ON turns on the sound function Press Enter key for confirmation Press lt SHIFT CAM gt key showing OFF turns off the sound function Press Enter key for confirmation The normal sound status is open 5 1 4 Matching Resistance 1500 Set Press MPX or Auto key three times until LCD displays 4 Match resister ON Displays the current set Your select ON Press lt SHIFT MON gt key showing ON this will place suited resistance between RS485 D and D Press l
14. eds lts speed can be divided into 64 grades 1 is the lowest speed and 64 is the fastest speed Press Exit key until the screen displays MON CAM DATA 01 0001 0000 1 In the Current state Press SHIFT EXIT key The Keyboard displays 1 speed dome Setup Number 0000 2 Enter the correct Speed Dome Unit and Press Enter key Example Preset Position for Speed Dome 3 The Keyboard displays 1 speed dome Setup Displays the Speed Dome Number 0003 Address 1 1024 3 Now the Keyboard displays Preset position 1 128 Running speed y 1 64 1 Position 000 Speed 00 Time 00 Dwell time 1 60 Press SHIFT MON the keyboard to move the cursor up and down 4 Press Clear key to delete previous data before programming to a new preset position 5 Enter desired Preset Position and Press Enter key 6 Press SHIFT MON key to get to Speed Using the number keys enter the desired running speed 7 Press SHIFT MON key to get to Time Using the number keys enter the desired dwell time For example Set the running speed of preset position No 6 as Grade 64 fastest speed dwelling time is 5 seconds Set the running speed of preset position No 2 as Grade 10 dwelling time is 10 seconds 1 Press MPX or Auto key Press Clear key to clear the data Input 06 Note Setting the Preset Position No 6 press Enter Key to Confirm Press SHIFT MON key to move the cursor to Speed 00
15. lt Input 64 press Enter key Press SHIFT MON key to move the cursor to Time 00 lt Input 05 press Enter key Press SHIFT MON to move the cursor back to 1 Position 001 lt 9 Press Clear to delete 0006 10 Input 02 press Enter key 11 Press SHIFT MON key to move the cursor to Speed 64 12 Press Clear to delete 64 13 Input 10 press Enter key 14 Press t SHIFT MON key to move the cursor to Time 05 lt 15 Press Clear to delete 05 16 Input 10 press Enter key D MN Oo A wh Do not forget to press ENTER to confirm each Preset Position Not doing so will result in lost information and the setting will not be effective 6 6 2 Pattern Tours Set 16 The keyboard can set pattern tour groups for the speed dome camera Before setting the Pattern Tours please set all preset positions in advance If the preset positions are not set the pattern tour will default to the pattern tour parameter Note can set 8 cruise groups 1 Press SHIFT EXIT key the keyboard displays 1 speed dome Setup Displays the Speed Dome Number 0000 Address 1 1024 2 Enter the correct Speed Dome Unit and Press Enter key Example Set Pattern Tour for Speed Dome Unit 02 The Keyboard displays 1 speed dome Setup Displays the Speed Dome Number 0002 Address 1 1024 3 Press MPX or Auto key until the keyboard displays 3 Add pre position Displays the
16. o and from scanning as the above route B Cruise Scanning frs IS 2 1 2 0 15 16 15 70 enen Make an auto cruise scanning Press EXIT key and exit to default status of the keyboard Then input cruise group No and then input Shift Scan Into cruise scanning as the above route A If a point is not set or is deleted after being set there will not be any scanning to these points Select gt _ Add the preset position to cruise Press Enter key for confirmation after adding a preset position Press SHIFT CAM key exit when setting is finished Please set the preset position parameter before setting its pattern tours If not setting dome preset position Dome Camera will operate default preset position parameter when it runs its pattern tours 6 7 Guard Location Set The guard location is an important position that the camera will come back to automatically when there is no operation for a defined period The user can set a guard location and control the waiting time to the guard location starting and stopping 1 255S before allowing the camera to return to the guard location Use the keyboard to set the guard location and its waiting time Turning the Guard Location On Off and Setting delay time to Guard Location 1 To set the guard location to start or stop The keyboard recognizes this action as a Switch ON Start OFF Stop Press SHIFT MON key ON Startup the guard location Press SHIFT CAM key OFF S
17. onments Connection connecting wire are diagramed below for reference w ajo AN AN AN AN AN AN ME OOOO OOO 00101 D O Alo y IN IN IN IN IN IN G o PTZ EOS 010010101010 OIOIOI 307 so He 10 slo sys D fs fs rs D D B O AC220V nh 2 na O O pS O O or r 10 oly D D D D D o o 4 le D he ja lg pia h lo 247 Jos 32 64 y RS232Communication y y Video Audio Vides udie Output Trapt 2 1 Video Audio Output connect connecting wire are diagramed below for reference 2 2 Video Audio Input connect connecting wire are diagramed below for reference 2 3 Communication connect RS485 Communication two RS485 Communication port RS232 Communication port Connect PC 2 3 1 RS485 Communication keyboard Connecting wire are diagramed below for reference O O O O O O O O O O O O O Connect Keyboard or Alarmer LAN A a Ae OO OOOO DOI Bla NY Pp p a aes 37 h7 lan jos 29 61 A FER E NO OOOO OIOIDIOIO O PIZ B 5 9 5 Os 6 9 PC ho h ro k k 30 6 fo 010101
18. rotocol and baud rate matrix switcher control dome Default setting is PELCO_D protocol Baud rate 2400Bit s gt the communication protocol baud rate should be confirmed Set the code switch keeping the setting consistent with the dome system The relative code switch site and connecting wire are diagramed below for reference O O Switch ui AES O Protocol setting are tabled below for reference Switch bit3 and bit4 BIT 3 BIT 4 Baud Rate OFF OFF 9600Bit s ON OFF 4800Bit s OFF ON 2400Bit s ON ON 1200Bit s Baud rate setting are tabled below for reference 3 2 Keyboard Parameters Set Press SHIFT EXIT key enter Keyboard main Menu Then Press MPX or Auto key until LCD displays 2 Keyboard setup Press Enter key into keyboard set up Menu Press MPX or Auto key to enter the subMenu Press EXIT key to exit to the main Menu 3 2 1 Keyboard ID No Set Press Enter key on keyboard screen Keyboard setup until LCD displays 1 Cur Keyboard ID XX Current keyboard ID No 0 Mast 1 16 Slave XX Input New ID No Input the number O must be zero press Enter key for confirmation New ID will be in effect immediately Note 1D 00 Main Control Keyboardf 3 2 2 Keyboard Baud Rate Set Press MPX or Auto key until LCD displays 2 Cur Baud Rate XXXX gt Current baud rate 12 24 48 9600 XXXX Input new ba
19. t SHIFT CAM gt key showing OFF this will separate suited resistance from RS485 D and D Press Enter key for confirmation The normal status is open 5 1 5 Keyboard Protocol Set Press MPX or Auto key four times until LCD displays P FIOREONRANGENT Displays the current set New Protocol Press 1 key showing RANCENT protocol press Enter key for confirmation Press 2 key showing PEL D PELCO D protocol press ENTER for confirmation Press 3 key showing PEL P PELCO P protocol press Enter key for confirmation default protocol is the our RANCENT Protocol Sometimes matching resistance should be set at the control center in order to avoid reflection and disturbance from RS 485 communication signal and other signals PELCO P PELCO D protocol The keyboard can be used together with other high speed domes When using a Camera please adopt the Vinte protocol 5 1 6 Keyboard Test Press MPX or Auto key until LCD displays 6 Keyboard test Press Enter key for confirmation a blank screen will appear Press any key except the lt EXIT gt key the relative name will display on the screen Press lt EXIT gt to leave the testing status and return to the main Menu A If the keyboard test does not display the correct Keyboard protocol the keyboard may be damaged 5 1 7 Max Vice Control Number Set 10 Press MPX or Auto
20. tion MPX Shift Call Set preset position 21
21. top guard location Example Press SHIFT MON key ON to start up guard location Dome will rotate to set position within XX seconds 2 In the Main Menu screen press MPX or Auto key until key once LCD displays 1 speed dome Setup Displays Current Speed Number 0000 dome address 3 Press Enter key to Confirm 4 Press MPX or Auto key until LCD displays 4 Watch Position Time 000 Switch 5 Input the desired waiting time using the number keys 17 Example After inputting time 05 press Enter key 4 Watch Position Time 005 Switch 6 8 Guard Location Parameter Set 1 When the keyboard is under default Main Menu status press MPX or Auto key until the keyboard displays 1 speed dome Setup Number 0000 2 Press Enter key to confirm 3 Press MPX or Auto key until the keyboard displays 3 Press Enter Key To Setup Watch Position 4 Move the joystick rocker to the target position you would like to set as the Guard Location 5 Press Enter key to set the Guard Location The position is set as the guard location 6 9 Intelligent Keyboard Menu Set for Press MPX or Auto key until keyboard will display Press MPX or Auto key 5 dome MENU Press enter to Menu 5 Dome Menu Data 0000 gt Data 0000 Press Clear key to delete previous data input required address of 1 1024 press Enter key Operating MENU
22. ture reaches higher point or lower point 7 4 Auxiliary Switch 2 Set Press MPX or Auto key until LCD display as below 6 Auxiliary 2 Number 0001 OFF Set Auxiliary Switch 2 open by pressing down SHIFT MON key Set Auxiliary Switch 2 close by pressing down SHIFT CAM key 7 5 Proportion Joystick A This function has been set well before the keyboard leaves the factory The speed of the Joystick is a direct ratio the running speed of the dome If it is not a direct ratio reset the keyboard joystick parameter Press MPX or Auto key until LCD displays 8 Joy Stick Set Tilt 000 Pan 000 Display Joystick value Up Down Left Right 8 1 Set Joystick middle value dwelling time When stop on the middle part set joystick middle status by pressing AREA key 8 2 Set joystick up limit value Move the joystick to top up set its upper limit value by pressing SEQ key 8 3 Set joystick down limit value Move the joystick to bottom set its lower limit value by pressing MON key 19 8 4 Set joystick left limit value Move the joystick to left side set its left limit value by pressing GRP key 8 5 Set joystick right limit value Move the joystick to right side set its right limit value by pressing Next key 8 6 Set joystick retrorse limit value limited for PTZ keyboard only Move the middle pillar of joystick to the bottom extrorsely set its retrorse limit value by pressing Pan_A ke
23. ud rate Optional baud rate 9600 must be 9600 Default baud rate 9600bps Input your required baud rate in DATA area and press Enter key for confirmation New baud rate is in effect immediately 3 2 3 Key press Sound Set Press MPX or Auto key until LCD displays 3 Current sound ON gt Displays current set Your select Select Sound preference Press lt SHIFT MON gt key showing ON turns on the sound function Press Enter key for confirmation Press lt SHIFT CAM gt key showing OFF turns off the sound function Press Enter key for confirmation The normal sound status is open 3 2 4 Matching Resistance 150Q Set Press MPX or Auto key three times until LCD displays 4 Match resister ON Displays the current set Your select ON Press lt SHIFT MON gt key showing ON this will place suited resistance between RS485 D and D Press lt SHIFT CAM gt key showing OFF this will separate suited resistance from RS485 D and D Press Enter key for confirmation The normal status is open 3 2 5 Keyboard Protocol Set Press MPX or Auto key four times until LCD displays 5 Protocol RANCENT Displays the current set New Protocol Press 1 key showing RANCENT protocol press Enter key for confirmation Note must be RANCENT 3 2 6 Keyboard Test Press MPX or Auto key until LCD displays 6 Keyboard test
24. y 8 7 Set joystick veering limit value limited for PTZ keyboard only Move the middle pillar of joystick to the bottom veer set its veering limit value by pressing Pan_B key See below chart for setting reference IX Exception Handles Exception Possible reason Relative solution phenomena No display on the 1 Power supply is not 1 Check connection of screen when the connected properly power line power on 2 Watt is notenough 2 See if power supply is AC DC 9V 12V No way to control 1 Protocol is not 1 Check if the keyboard designated dome or correct protocol accords with high speed dome 2 Baud rate is not that of dome or correct high speed ball or not 3 Controlled address 2 Check if the baud rate is not correct of the keyboard accord 4the polarity of with that of dome or control line is not high speed ball or not correct 3 The number in CAM or DATA area can t accord with the object address pressing key closed in the keyboard set Other phenomena Back to manufacturer for o AA A When using the keyboard to control other dome cameras keep the keyboard setting Baud rate protocol address consistent with the dome camera Some dome camera 20 addresses have a 1 difference the keyboard does not X Key press Function RANCENT Protocol Operating Limited Site A Shift_ Pan A Limited B Auto Line Scan scanning between two points Shits Scan PELCO_D Protocol Operating Adjust preset posi