Home

user guide - Bayer Diabetes Canada

image

Contents

1. SEND OPTIONS 5 To change the current Send Option press Go Back Change Send is set to Always SEND OPTIONS T Automatically send Papal 6 Choose the Send Option results to the Pump 2a that is best for you Never Send Options set Meter will ask you 7 Aconfirmation screen appears Press OK to return to Pump Options before sending results Test Reminders A reminder for your next test can be set after testing or from the Setup Menu See page 31 for Setting a Test Reminder after Testing Setting a Reminder 1 Press and hold the top Menu button to turn the meter on 2 Press the button next to Setup SETUP 3 Press the W button to Pump Options highlight Reminder Off Press OK to turn ON the fate reminder REMINDER 4 To accept the preset COUNTOOLWN eras time shown select Start 9 00 Change To change the time hrs mins ta Back select Change Use the A and F buttons to change the reminder time in 15 minute increments from 15 minutes to 23 hours 45 minutes SJOPUILUOY ISOL Sc Pn z 2L cm Turning Off a Reminder Lu pm 2 ie V MAIN MENU REMINDER 5 After you have selected CHANGE COUNTDOWN x hours press OK After you 2 2 have selected minutes hrs press OK Reminder in l 6 A confirmation screen appears and you can select Change or Done Change Se 15 mins a Done If you accept the reminder a reminder icon O wi
2. eeee 52 LANGUES iisa 53 Pump Options 3 sccrtetasmatncnncwaneccteceuencre 38 FAG IIIS Ss tncarscanssncbcerarninsetetemmtencetans 43 SOUNO eee ee eee eee eee 47 Targets i arctdssg canaiveseaguaestoacacentdeecantusees 49 TINE E EE E E 46 Trends Range cccccseeeeeeeceeeeeeees 51 SOUNAON OM sesers 47 Strip Port Light cvetsasctdendenwavavwoeaveniens 4 DS aeea 2 Underfilled Stl Ds enc sccesstnctndenateceaenesers 16 Supplies Replacement Parts 70 Symbols Used svete cascuisvrassereacanetennees 64 Symptoms of High Low Blood SUGAT sictduisutouncusiaceuednndelninewrns 59 System Specifications 008 65 Target RANGeS ccccccsesseeesesseeesees 11 With AutoLog ifresccccnsenesccceasctendcctiens 49 With AutoLog ON srxdisiccnccanechasacecwesiact 50 Technical Information cc000 60 Test Strip Port Light cccccceee 4 Test SIPS asccnidesvanrecivasnscdewnsancsenanaccns 2 WS SUNG andains aia 12 Alternative Site Testing AST 19 Fingertip Testing seccceshnendcetssnnceencebexs 15 Testing in the Dark scsssacivaccusaxbobeaxatnecs 26 Testing with AutoLog Off 008 17 Testing with AutoLog ON 18 Testing Your Blood Sugar 05 12 TIE esaa R 46 Format 12 hour or 24 hour clock 46 Setting ieser re 46 Trends Averages Summaries 36 Viewing with AutoLog Off 05 36 Viewing with AutoLog On 0 37
3. w L pue eqd lt c Pn Zg n 2L cm setting or Changing the Time Sound 1 Press and hold the top Menu button to turn the meter on Turning the Sound On Off 2 Press the button next to Setup Sound is ON when you receive your meter Some error messages and the Reminder bell will override the Sound 3 Press the V button to Off setting highlight Time Press Ok 1 Press and hold the top Menu button to turn the meter on to select 2 Press the button next to Setup TIME 3 Press the V button to Z4 HOUR CLOCK channel 4 To change the time select Sound Press OK ees al press Change O 1 1 30 Go Back SOUND 4 To turn the sound OFF D a s ress Turn Off To kee fae 5 Select either the 12 Hour Sound is On i d turned ON p 2 12 Hour Clock Clock or 24 Hour Clock ecu i 6 24 Hour Clock opua O Sound is Off z TIME i 6 Press the A or V button A screen confirms N CHANGE HOURS to aa Hg collec da your choice E and minute Press OK after a 30 AM each selection 7 If you have selected the AutoLog heer oa Galva NOTE Your meter comes with AutoLog turned OFF to select AM or PM The AutoLog feature lets you mark your test result as Time is set Before Meal After Meal 8 Time is set A screen 10 30 am Ti lt T2 SO E S az Z 2 YO lt q 2L 25 cm confirms your choice To Turn On AutoLog Press Done 1 Press and hold the top Menu button to turn the meter on 2 Pre
4. Connecting the Meter and Pump USING THE MAIN MENU 8 Scroll to Connect Devices and press ACT Then scroll to Meters and press ACT NOTE If your UTILITIES MENU does not contain Connect Devices scroll to Meter Options and press ACT 9 Select n and press ACT If you are replacing a meter go to Step 10 If you are adding a new meter go to Step 12 10 To replace a meter select Delete ID and press ACT 11 If you have multiple meter IDs repeat Step 10 for each one 12 To add a new meter select Add ID and press ACT Refer to Step 6 or see meter back to find meter ID SN Use the up and down arrow buttons to enter the six character meter ID shown on the meter screen Press ACT after each character entry 13 Select Review ID on your compatible Medtronic device to confirm that your CONTOUR NEXT LINK meter ID has been correctly entered If incorrect go back to Step 10 NOTE For detailed instructions see your compatible Medtronic device user guide 14 Return to your CONTOUR NEXT LINK meter After you have entered the meter ID into your compatible Medtronic device press Mert CONNECT TO PUMP Enter this Meter ID into your pump aei 123456 Go Back 15 After the meter and pump are connected you set your Send Options This controls how your meter sends blood glucose readings to your Medtronic pump Choose the Send Option that is best for you Your options are
5. 300 mA 30 C Strip Storage Temperature Range x X 30 C Normal Control Storage Temperature Range a Meter Operating Temperature Range i po Humidity 10 93 RH Dimensions 97 mm wide x 31 mm high x 18 mm thick Weight 43 grams Sound Output 45 to 80 dBA at a distance of 10 cm Electromagnetic Compatibility EMC The CONTOUR NEXT LINK meter complies with the electromagnetic requirements specified in ISO 15197 2003 Electromagnetic emissions are low and unlikely to interfere with other nearby electronic equipment nor are emissions from nearby electronic equipment likely to interfere with the CONTOUR NEXT LINK meter Immunity to electrostatic discharge meets the requirements of IEC 61000 4 2 2008 It is advisable to avoid use of electronic devices in very dry environments especially if synthetic materials are present The CONTOUR NEXT LINK meter has been tested for radio frequency interference at the frequency range and test levels specified by ISO 15197 2003 To avoid radio frequency interference do not use the CONTOUR NEXT LINK meter near cellular or cordless telephones walkie talkies garage door openers radio transmitters or other electrical or electronic equipment that are sources of electromagnetic radiation as these may interfere with the proper operation of the meter SUOIEDIJIO9dS WIa SAS IWOINHOAL gt Z s 2 gt J m Cleaning and Disinfection _l lt Z z 8 LUI H AND CARE
6. Results in mmol L will always have a decimal point Results in mg dL will never have a decimal point Example D 2 or O3i Check your display screen to be sure the results are shown the right way If not please see Bayer Customer Service contact information on the back cover of this user guide e The CONTOUR NEXT LINK wireless blood glucose monitoring system from Bayer has a measuring range of 1 1 mmol L to 33 3 mmol L For results under 1 1 mmol L or over 33 3 mmol L If your blood sugar reading is under 1 1 mmol L the Fallow Medical Advice Immediately screen will display and the meter will beep twice Contact your health care professional o If your blood sugar reading is over 33 3 mmol L the next screen will tell you to retest The meter will beep twice If results are still over 33 3 mmol L Follow Medical Advice Immediately is displayed e Please be aware that USB ports in some computers and self powered USB hubs can become much warmer than the room A USB extension cable is available If you wish to test immediately after disconnecting from your computer please use the USB cable to protect the meter from exposure to heat created by the computer CAUTION Your CONTOUR NEXT LINK meter only works with CONTOUR NEXT test strips and CONTOUR NEXT control solutions Rechargeable Battery The CONTOUR NEXT LINK meter from Bayer has a rechargeable battery You must charge your battery before you can use your
7. always Meter will always send results Ask Me Meter will ask you before sending results Never Meter will never send results SEND OPTIONS Automatically send Always ab ae To change your choice see page 42 results to the Pump Neyer 41 dung pue 419 94 Bun oeUuUOD Sc Pn z 2L cm Changing the Send Option USING THE MAIN MENU 16 The next screen confirms your Send Option choice Press OK Send Options set Meter will ask you before sending results NOTE If you want to disconnect the pump from the meter you do not need to take action on your meter Please refer to your Medtronic device user guide Changing the Send Option Send Options control how your meter sends your test results to your pump You have 3 choices Always Meter will always send results Ask Me Meter will ask you before sending results Never Meter will never send results NOTE You may want to test with the Send Option set to Never if you do not want to create a wireless signal for example if you have been asked to turn off all electronic devices on an aircraft 1 Press and hold the top Menu button to turn the meter on 2 Press the button next to Setup aoe 3 Press the V button to highlight Pump Options Reminder Press OK to select Date PUMP OPTIONS Send Options ET 4 Press Send Options Go Back NOTE For Connection settings see page 38 Contour ry next link
8. hibernate or power save mode The test strip port light flashes during charging and stops flashing and turns off when charging is complete Please remove the meter and store in the wallet until you are ready to test Battery Charging When you plug your meter into your wall charger or computer it starts to charge immediately While the battery charges the test strip port light flashes slowly Press the top Menu button at any time to display the charging status Contour ry next link Rapid Charge lf the battery is low when you plug in your meter it will Rapid Charge for about 1 minute You can run a blood sugar test as soon as Rapid Charge is complete and you have unplugged the meter Do Not Test Normal Charging When Rapid Charge ends normal charging is expected to last up to 2 hours when plugged into a high powered USB port When the battery is fully charged the test strip port light turns off CAUTION Please be aware that USB ports in some computers and self powered USB hubs can become much warmer than the room If you wish to test immediately after disconnecting from your computer please use the USB cable to protect the meter from exposure to heat created by the computer NOTE If the charging status displays Low Power Charging your CONTOUR NEXT LINK meter may be plugged into a low powered USB port Please try a different USB port on your computer Only connect to a computer or a 5V charger ap
9. 10 41 10 Accept 12 00 PM Change 17 The date and time on your meter must match the date and time on your Medtronic device Pick up Medtronic device Press ACT fam togo to the MAIN MENU Scroll to Utilities and press ACT Scroll to Time Date and press ACT Select a time format and press ACT Note the time and date Return to your meter Follow instructions on your meter to change the time and date to match your Medtronic device AutoLog The AutoLog feature lets you mark your test result as Before Meal 3z After Meal Your meter comes preset with AutoLog turned OFF AUTOLOG AutoLlog is Off Accept Turn On 18 When the AutoLog screen appears press Accept to keep AutoLog OFF Or to activate AutoLog select Turn On 9 a Jo gt J s ma o 0 21A q 21UO P WN Y27 eWN 0 OWI pue 32d 19S oa Z ul ey F lt W j On High and Low Alerts 10 High and Low Alerts The High and Low Alert feature tells you when your test result is above or below the settings you choose Results above High are marked High Blood Sugar Results below Low are marked Low Blood Sugar Alerts appear as large orange numbers NOTE Alerts can only be set outside your selected Target Range s For additional information you may contact Customer Service Contact information for Customer Service is on the back cover A WARNING Talk to your health care professional before setting any High or Low
10. 148 11 0G ec y After Meal time displayed REMINDER 2 To stop the countdown REMINDER IM i press Stop Change A confirmation screen L hr 30 mins Go Back appears and the countdown stops Contour ry next link Changing a Reminder Time 1 Press the A or V button to select the correct hours and minutes in 15 minute increments REMINDER CHANGE COUNTOOLN D NN 2 Press OK after 3 hrs each selection Reminder in A screen confirms the reminder countdown time 3 hrs 15 mins When the Reminder feature is on the clock symbol appears in the headers on the Setup and Main Menu screens The meter retains the reminder time that you set until you change it or turn it off Getting a Reminder When the reminder time is reached 20 beeps will sound The meter will turn on and a reminder screen will appear You can stop the beeps in two ways Time for your next 1 Press 0K insert a test strip test pers and proceed with testing OR 2 Insert a test strip and proceed with testing see page 12 NOTE If you decide to test within 15 minutes before the reminder time the countdown is stopped with the insertion of the test strip Proceed with testing 33 TI gt ol Cc J m ow JopulUEaY e Huibueyy YY Lu a lt Lu Li Notes Notes You may add notes to your test result that may help explain results Your notes will be saved in the Logbook The option to add a
11. Alerts on your meter Your meter comes preset with a high alert level of 13 9 mmol L and a low alert level of 3 9 mmol L You can Accept or Change these levels HIGH AND LOW ALERTS High 13 9 Low 39 19 Select Accept to keep the preset alert levels If you Accept wish to change these Change NOTE Your Target ranges must be within your High and Low Alert levels You set your Target ranges next HIGH AND LOW ALERTS High 20 If you selected Change press the A or V button to select your High Alert level This can be set between 7 0 20 0 mmol L Press OK Low 3 9 Contour ry next link alert levels press Change 21 Press the A or V HIGH AND LOW ALERTS High 14 0 button to select your N O ee Low Alert level This gt m Low can be set between 4 m 3 0 5 5 mmol L nS Press OK NOTE Press and hold the A or V button to scroll through the numbers faster 22 The next screen confirms your choices Press Accept to confirm your Alert settings Alerts are set High 14 0 Low 3 8 sobuey obuey Target Ranges Next you are asked to accept your blood sugar Targets Targets are your personal ranges for your blood sugar results With AutoLog OFF you have a single Target range With AutoLog ON you have Target ranges for Fasting Before Meal and After Meal NOTE Targets can only be set inside your selected Alert level s For additional information you may contact C
12. Customer Service Please see back cover for contact Service Information If you have a problem and none of the problem solving messages on the meter help contact Bayer Customer Service Please see back cover for contact information We have trained specialists to help you Important Speak to a Bayer Customer Service Representative before returning your meter for any reason He she will give you the information needed to get your problem handled correctly and efficiently Have your CONTOUR NEXT LINK blood glucose meter and CONTOUR NEXT test strips available when you phone It would also be helpful to have a bottle of CONTOUR NEXT control solution suitable for your test strips nearby Check List This check list may be helpful when speaking with Bayer Customer Service 1 Locate the model number A and serial number B on the back of the meter 2 Locate the test strips expiry date on the bottle 3 Check the battery symbol E on the screen See page 55 Battery Status UONEWUOJU 3211S Comparison Options information _l lt Z E O LUI H AND CARE IWOINHOAL gt Z s 2 gt J m Contour ry next link Symbols Used AND CARE _l lt Z E O LUI H Symbols Used The following symbols are used throughout the product labeling for the CONTOUR NEXT LINK blood glucose monitoring system meter packaging and labeling and reagent and control solution packaging and labelin
13. MarkerS AUtOLog c00000e 9 Medtronic PUMP wicasiessacienstsaradeuasecsinads 3 Memory Logbook ccccccsssseeeeeees 35 Menu UR OM ite asian iccansnedionsse icanakateneneds 4 METOT css eesationece irean R RTA RAS 4 NSO S AMesie csccaniceusstanetinacncneccnnetaameien 58 OV ENVIEW lt cccesanstccniiaatetestulncettccaiianctecats 4 Meter Care cccccssccccsssseeeseeseeeeeees 66 mg dL milligrams per decilitre vV mmol L millimoles per litre v NOOS scos roca cuateecaniiene veces cie undead deceueas 34 Adding to a Test Result ceee 34 Removing a NOS sidcccsaccnminixaxeccortxreeee 34 On Off Meter ccccceseeeeeeeeeeeees 4 PREC SIONS enaena 61 Pump Connection cccccseeeeeeeee 38 PUMP ODTONS cciesccstesatwscodncsaueniseatnden 38 PICIINOIGT Serica acntivevartatesttvcsauiiecmuetyates 31 Setting After Testing eseeeeee 31 Setting From Setup Menu 43 OIE oerien 44 Sample Volume ccccceeeeeeeeeeees 65 Scrolling Selection Buttons 4 Send Options siccccticdtwnsiessideevarecadberdan 8 Change Setting ccccccccccscceseeeeeees 8 Sending Test Results to Pump 30 Service Information ccccceeeees 63 Setup MENU ccs ncinecdesvbaivceneversmavaied 38 AUTOLOG siaren a 47 Customer ServiCe ccccccsssseeeeeeeees 53 D le cerre andeea snc eeeecannnceavecencnraseiee 45 High and Low Alerts
14. U LUI H Testing With AutoLog On 18 Testing With AutoLog On AUTOLOG After you apply blood to the C test strip use the W to select Before Meal Fasting Before Meal After Y After Meal Meal or No Mark and then No Mlark press OK Scroll down to see No Mark NOTE e Your test result does not display until you make an AutoLog selection e If your result is above or below your High or Low Alert settings you will see your result without pushing a button The Fasting marker can be used when testing blood sugar levels after going without food and sugared drink for 8 hours The Before Meal marker can be used when Before Meal testing blood sugar levels within 1 hour before a meal a The After Meal marker can be used when T After Meal testing blood sugar levels within 2 hours after a meal You can select No Mark if you are testing at times other than before or after a meal or fasting If you make your AutoLog selection very quickly you may see the remainder of the testing countdown Your test result appears as a large number and then changes to the usual test result screen Contour RY next link YOUR RESULTS If Always was selected in Send Options during Setup your result is automatically sent to your pump If Never was selected in Send Options you will not have the option to send the result to your pump If ask Me was selected in Send Options you can choose to send your re
15. a meal insulin dose or exercise If you are unable to feel symptoms of low blood sugar hypoglycaemic unawareness If you get alternative site blood sugar results that do not agree with how you feel e During illness or times of stress e f you will be driving a car or operating machinery Alternative Site test results may be different from fingertip results when glucose levels are changing rapidly e g after a meal after taking insulin or during or after exercise Additionally glucose levels may not rise as high or fall as low as levels in the fingertip As such fingertip testing results may identify hypoglycaemic levels sooner than alternate site results Alternative Site Testing is recommended only when it is more than 2 hours after a meal diabetes medication or exercise If you do not have a clear endcap to perform AST contact Bayer Customer Service Please see back cover for contact information Getting a Blood Drop for Alternative Site Testing a CA 1 Wash your hands and the A puncture site with soap and warm ee IS 5s water Rinse and dry well E r i EO 2 Attach the clear AST endcap to the MICROLET 2 lancing device f f 3 Select a puncture site from Fi a fleshy area on the palm Avoid veins moles bones and tendons i f i J r L Contour ry next link TA A 4 Press the clear endcap VF firmly against the puncture eee ca site and then press the blue Y T m r
16. an aircraft e Always check the display on your pump to ensure that the glucose result shown agrees with the meter display Test Reminders A reminder for your next test can be set after testing OR from the Setup Menu see page 43 A reminder can be set in 15 minute increments from 15 minutes to 23 hours 45 minutes Setting a Test Reminder 16 368 AM 18 11 1 With the test strip Reminder still in the meter A press Reminder Before Meal Hotes SETUP OR from the Setup Menu Pump Options press the W button to highlight Reminder Off Press Hate OK to turn the Reminder ON 31 TI gt ol Cc J m SJOPUILUOY S L YY Lu a lt Lu Li Test Reminders o Start 2 Press Start to begin the countdown The preset time is 2 hours or if you have changed it the last reminder time that you set is now the default REMINDER COUNTDOWN lt Change 2 hrs Go Back fseminDER a mn You can change Start COUnTOOLN es the Reminder Change Countdown time by 2 hs Go Back pressing Change Turning Off a Test Reminder A reminder can be turned off or changed after testing or from the Setup Menu NOTE If you do a blood sugar test within 15 minutes of a set reminder the reminder turns off automatically 1 Press Reminder If the countdown is currently on the screen will read Reminder In with the remaining amount of 14 36 AM
17. before testing Please follow all instructions for use and care exactly as described Contour ry next link 12 Examine product for missing damaged or broken parts If the test strip bottle is open inside a new box of strips do not use those strips Contact Bayer Customer Service for replacement parts Please see back cover for contact information CAUTION Your CONTOUR NEXT LINK meter only works with CONTOUR NEXT test strips and CONTOUR NEXT control solutions Have all the materials you need ready before you begin testing This includes your CONTOUR NEXT LINK meter CONTOUR NEXT test strips and the MICROLET 2 lancing device and MICROLET lancets You may also need CONTOUR NEXT control solution to perform a quality control check CONTOUR NEXT control solutions are available separately if not included in the meter kit e Do not perform a blood glucose test when your meter is connected to an external device e g computer e Use only approved cables or wall charger from the manufacturer or a 5V charger approved by a certified body such as UL TUV or CSA Preparing the Lancing Device VAN WARNING Potential Biohazard The MICROLET 2 lancing device is intended for self testing by a single patient It must not be used on more than one person due to the risk of infection Q Use a new MICROLET lancet each time you test because it is no longer sterile after use Read the MICROLET 2 lancing device insert for com
18. date and discard date on the control solution bottle DO NOT use expired materials Normal Low and High control solutions are available separately if not included in the meter kit Always use CONTOUR NEXT control solutions from Bayer Other brands could present incorrect results If you need help locating CONTOUR NEXT control solutions from Bayer contact Bayer Customer Service Please see back cover for contact information 1 Remove the test strip from the bottle and firmly snap the lid closed 27 m Z Q Hulsey uonnjos jo1 U0D TESTING Control Solution Testing 2 Hold the test strip with the grey square end facing up 3 Insert the grey square end of the test strip into the test strip port until the meter beeps APPLY BLOOD 4 You will see the Apply Blood screen The meter is i now ready for you to test 5 Shake the control solution bottle well before every use 6 Remove bottle cap and use a tissue to wipe away any solution around the bottle tip before dispensing a drop 7 Squeeze a small drop of control solution on a clean non absorbent surface Do not apply control solution to your finger or to the test strip directly from the bottle 8 Immediately touch the tip of the test strip to the drop of control solution 9 Hold the tip in the drop until the meter beeps Contour RY next link 18 38 AM 168 11 10 The meter shows the AutoLog screen if Auto
19. meter and you cannot do a blood sugar test while the battery is charging Charge Your Meter Using a Wall Outlet or a Computer Remove USB cap e Insert the meter USB plug into the wall charger or use the USB extension cable _ The meter is fully charged when the test strip port light stops flashing and turns off Charger is available separately from Bayer Customer Service if not included in your meter kit See contact information for Bayer Customer Service on back cover CAUTION Do not perform a blood glucose test when your meter is connected to an external device e g computer NOTE Your meter can Rapid Charge After 1 minute of charging you can unplug the meter and run one blood sugar test if needed A USB extension cable is included for your convenience C a OR e Remove USB cap e Insert the meter USB plug into your computer or use the USB extension cable e Be sure your computer is turned on and not in sleep hibernate or power save mode CAUTION Please be aware that USB ports in some computers and self powered USB hubs can become much warmer than the room If you wish to test immediately after disconnecting from your computer please use the USB cable to protect the meter from exposure to heat created by the computer Table of Contents Your CONTOUR NEXT LINK Wireless Blood Glucose Monitoring System from Bayet cc sssccesssseeeeeseseeeeeees Your GONTOUR NEXT Test S
20. that this instrument will be free from defects in materials and workmanship for 5 years from the date of original purchase except as noted below During the stated 5 year period Bayer HealthCare shall at no charge replace a unit found to be defective with an equivalent or current version of the owner s model Limitations of Warranty This warranty is subject to the following exceptions and limitations 1 A 90 day warranty only will be extended for consumable parts and or accessories 2 This warranty is limited to replacement due to defects in parts or workmanship Bayer HealthCare shall not be required to replace any units which malfunction or are damaged due to abuse accidents alteration modification misuse neglect maintenance by someone other than Bayer HealthCare or failure to operate the instrument in accordance with instructions Further Bayer HealthCare assumes no liability for malfunction or damage to Bayer HealthCare instruments caused by the use of reagents other than the appropriate reagents e g CONTOUR NEXT test strips manufactured or recommended by Bayer HealthCare 3 Bayer HealthCare reserves the right to make changes in design of this instrument without obligation to incorporate such changes into previously manufactured instruments 4 Bayer HealthCare has no knowledge of the performance of the CONTOUR NEXT LINK blood glucose meter when used with any test strips other than CONTOUR NEXT test strips
21. wet For proper disinfection you must keep all lancing device surfaces wet for 60 seconds uoo zuis q pue Hulues y IWOINHOAL gt Z s 2 gt J m Signs of Deterioration l lt Z E O LUI H AND CARE 4 Use the germicidal wipes to disinfect all exposed A surfaces of your lancing device until wet s A D i d 5 Dry all lancing device surfaces and endcap with a clean paper towel if needed Signs of Deterioration Your MICROLET 2 lancing device has been tested for 260 cycles of the cleaning and disinfection procedure one cycle per week for 5 years The MICROLET 2 lancing device has been demonstrated to withstand 5 years of cleaning and disinfection without damage However if your device malfunctions for any cause contact Bayer Customer Service to troubleshoot the issue and provide a solution Please see back cover for contact information Warranty Your MICROLET 2 lancing device is warranted for 5 years Supplies When calling or writing for supplies be sure to include the name of the replacement part or accessory item Contour ry next link Replacement Parts ltems e CONTOUR NEXT LINK user guide e CONTOUR NEXT LINK quick reference guide e USB extension cable from Bayer e USB cap e Wall charger e CONTOUR NEXT test strips e CONTOUR NEXT control solution e MICROLET 2 lancing device e MICROLET lancets e Check the website www bayerdiabetes com for
22. 25 Alternative Site Testing AST 19 Apply More BIOOd ccceccceeeeees 16 AutoLog Meal Marking 0000 9 Turning Off aereaent avetatestaaneccresennsanensase 48 TUIN Oieee ninas EERE 47 Averages Trends csssccceessesseeeees 36 Back Go Back toa Previous Screen ssececseeeeeeeeees 4 EINE R APPA E T 55 Charge serene 56 Rapid Charge cccccccecseeseseeeeeeeeeeees 57 REMOVA lises 58 Status Display sacasienceiceaasecimediatvenennceds 55 BloGG DIOP saice ectatccansiasteasenstetecesmads 15 Obtaining for Alternative Site TSSUNO iancsacunctencnastsiadexenanecatenenakt 20 Obtaining for Fingertip Testing 15 BUWONS sasssa 4 OR eare 4 Scrolling Selection cceceeseseeeeeeeeees 4 Top MIG vvecenscsessswatieseaanesdsccacennatecesan 4 Caring for your Meter ccc00 66 Changing Alerts ccccccsssceeeeeesees 10 Changing Targets cccccesscceeeeeees 49 Cleaning and Disinfection 66 Connecting Meter and Pump 38 CONTOUR NEXT Control SOMIION sess senccncnssacuecendsxaceoness 27 Test MID te paniacensmaceatecamenctevechmncsnicoen 2 Control Solution Testing 006 27 Customer ServiCe ccccccsesceeeeeesees 53 Contact Number 06 Back cover NS E AI PA EEA 45 Format Day Month Year or Month Day Year sicissiccscccaiencnsiccecas 45 SeHING scarann aE Rn EERE 45 Disconnecting Meter and Pump 42 14 ENOC soca
23. Caring for Your Meter Store your meter in the carrying case provided whenever possible e Wash hands and dry well before handling to keep the meter and test strips free of water oils and other contaminants Keep blood control solution and cleaning fluid from entering the test strip port or USB plug Handle the meter carefully to avoid damaging the electronics or causing other malfunctions e The USB cap of your CONTOUR NEXT LINK meter is designed to protect the USB plug Should you lose the cap contact Bayer Customer Service for a replacement Please see back cover for contact information Cleaning and Disinfection Your CONTOUR NEXT LINK system should be cleaned and disinfected once a week Use only germicidal wipes containing 0 55 sodium hypochlorite bleach which has been proven to be safe to use with the CONTOUR NEXT LINK meter and MICROLET 2 lancing device Cleaning is the removal of visible dirt and debris but does not reduce the risk for transmission of infectious diseases Your CONTOUR NEXT LINK system should be cleaned of dirt and debris once a week Disinfecting if performed properly reduces the risk of transmitting infectious diseases Your meter and lancing device should be disinfected once a week A WARNING Always wash your hands well with soap and water before and after testing and handling the meter lancing device or test strips NOTE If the meter is being operated by a second person who
24. Contour next in Wireless Blood Glucose Monitoring System Uses only CONTOUR NEXT blood glucose test strips from Bayer USER GUIDE INTENDED USE The CONTOUR NEXT LINK wireless blood glucose monitoring system from Bayer meter test strips and control solution is intended for self testing by persons with diabetes to monitor glucose concentrations for the quantitative measurement of glucose in fresh capillary whole blood drawn from the fingertip or palm It is intended for in vitro diagnostic use only The clinical utility of this device is that it may be used as an aid to monitor the effectiveness of a diabetes control program The CONTOUR NEXT LINK wireless blood glucose monitoring system is intended to be used to transmit glucose values to compatible Medtronic devices and facilitate transfer of information to Medtronic CareLink software through use of radio frequency communication The CONTOUR NEXT LINK wireless blood glucose monitoring system from Bayer is not intended for the diagnosis of or screening for diabetes mellitus and it is not intended for use on neonates The CONTOUR NEXT LINK wireless blood glucose monitoring system is intended for single patient use only and should not be shared IMPORTANT SAFETY INFORMATION Serious Illness e Capillary fingerstick or Alternative Site blood glucose testing may not be clinically appropriate when peripheral flow is decreased Shock severe hypotension hyperosmolar hyperglyca
25. Log is ON but will sense control solution The meter will count down for 5 seconds and the control test result will display on the meter It automatically marks the result as a Control Test and stores it in memory Control test results are not included in your blood sugar averages Control Test 11 Compare your control test result to the ranges printed on the test strip bottle 12 Remove test strip To turn the meter off press and hold the Menu button OR after 3 minutes of inactivity the meter turns off Dispose of the used test strip as medical waste or as advised by your health care professional NOTE Control test results that are marked as Control Test are not transmitted to the pump AN WARNING e If the control solution test result is out of range the result may be transmitted to your pump when in Always send mode see page 30 e Do not send an out of range control result to your pump CAUTION If your control solution test result is out of range contact Bayer Customer Service Please see back cover for contact information Do not use the meter or test strips for blood glucose testing until the issue is resolved 29 m Z Q Bus uonjos jO1 U0D U Lu a lt Lu Li AutoLog Marking Your Results Features Your CONTOUR NEXT LINK meter includes many testing features AutoLog Marking Your Results Your meter comes with an AutoLog feature tha
26. OLET 2 Lancing Device Re setting Handle Grip Indent tial Release Button Lancet Holder Lancet a Round Protective Cap O Endcap Dial Adjustable Grey Endcap fingertip r Alternative Site Testing Clear Endcap palm AST Endcap may not be included in all meter kits Talks to Your Compatible Medtronic Device Your CONTOUR NEXT LINK meter can automatically send your blood glucose result directly to your compatible Medtronic device if your meter and pump are linked This eliminates the need to manually enter your blood glucose result into your insulin pump Your compatible Medtronic device will only accept the glucose result if the Meter Send Option in your device s Utility Menu is set to On and you have programmed the device with the meter s ID serial number Up to 3 CONTOUR NEXT LINK meters can be connected to your Medtronic pump To use the meter link features your CONTOUR NEXT LINK meter and Medtronic device must be within 1 22 meters of each other If you are not using the meter link feature you may want to set the Send Option to Never on your CONTOUR NEXT LINK meter to save battery power a Jo gt J s ma o 0 Jln q uue ZoLITOYIIN INOA oa Z ul ey F lt W j On Meter Overview 4 Meter Overview Turning the Meter On or Off e Press and hold the top Menu button to turn the meter on or off e Insert a test strip to turn the meter on e Meter tu
27. ONTOUR NEXT LINK system is designed for use with capillary whole blood Comparison to a laboratory method must be done simultaneously with aliquots of the same sample Note Glucose concentrations drop rapidly due to glycolysis approximately 5 7 per hour 8 Important Information This equipment has been tested and found to comply with the Industry Canada Standard in RSS 210 This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver Industry Canada Statement The term IC before the certification registration number only signifies that the Industry Canada technical specifications were met Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device If you have questions please contact Bayer
28. ORE BLOOD HOW You have about 30 seconds to apply more blood to the same strip If you do not re apply Remove used Strip enough blood within about Repeat test with new 30 seconds you will see a cai Strip screen telling you to remove the strip and repeat with a new strip Contour ry next link Test Results Testing With AutoLog Off After applying blood to the test strip when AutoLog is turned OFF your result will appear after the 5 second countdown m Z Q YOUR RESULTS lf Always was selected in ae Send Options during Setup 5 3 i your result is automatically Mme sent to your pump If Never was selected in Send Options you will not have the option to send the result to your pump If ask Me was selected in Send Options you can choose to send your result to your pump after each blood sugar test Press Send or Don t Send If Send is chosen press 0K on the Send confirmation screen Leave the test strip in the meter to set an optional reminder for your next test see page 31 or add a note see page 34 s NsoyY S L 16 368 AM ee Reminder Motes If you are done remove the test strip from the meter Press and hold the top Menu button to turn off the meter The meter also turns off after 3 minutes of inactivity CAUTION Always check the display on your pump to ensure that the glucose result shown agrees with the glucose result shown on the meter 17 2
29. Trends Range Setting c608 51 Turning Meter Off ON cccccceseceeees 4 Underfilled Strip cccccccssseeeeeees 16 USB Extension Cable 0006 vi WI UA es ezarceicte eae stadaaraceacaaceieerencee 72 WEDS S ticsinncscvsctteancverewinces Back cover Wireless Turning On Off 42 15 Bayer HealthCare Manufactured for Bayer HealthCare LLC Subsidiary of Bayer Corporation Mishawaka IN 46544 USA Distributed by Bayer Inc Toronto Ontario M9W 1G6 Canada www bayerdiabetes ca Bayer Customer Service is available from 9 a m to 9 p m EST 7 days a week at 1 800 268 7200 www bayerdiabetes ca TM Trademarks of Bayer HealthCare LLC used under license by Bayer Inc Bayer and Bayer Cross are registered trademarks of Bayer AG used under license by Bayer Inc All other trademarks are the property of their respective owners gt Medtronic Bayer 2013 Bayer Inc All rights reserved bf 83940409 Rev 01 14
30. Z E O LUI H AND CARE F Buttons USB Connector under cap Strip Port Disinfecting Your Meter Supplies Needed for Disinfecting e Germicidal wipes containing 0 55 sodium hypochlorite bleach e Paper towels e Timing device 1 Before disinfecting clean the meter as described in Cleaning Your Meter For proper disinfection you must keep all meter surfaces wet for 60 seconds Using a new germicidal wipe carefully wipe all outer surfaces of your meter until wet Do not allow cleaning solution to run into the meter through areas such as around the buttons or the meter s test strip or data ports 2 Dry all meter surfaces and test strip port using a clean paper towel if needed Cleaning Your Lancing Device Supplies Needed for Cleaning e Germicidal wipes containing 0 55 sodium hypochlorite bleach e Paper towels 1 Clean the MICROLET 2 lancing device with germicidal wipes until all soil is removed 2 Dry as necessary with a clean paper towel Contour RY next link Disinfecting Your Lancing Device Supplies Needed for Disinfecting e Germicidal wipes containing 0 55 sodium hypochlorite bleach e Paper towels e Timing device 1 Before disinfecting clean the lancing device as described above in Cleaning Your Lancing Device 2 Remove the endcap and lancet if present 3 Using a new germicidal wipe carefully wipe all external and internal surfaces of the endcap until
31. and therefore makes no warranty of the performance of the CONTOUR NEXT LINK meter when used with any test strips other than CONTOUR NEXT test strips or when the CONTOUR NEXT test strip is altered or modified in any manner Contour ry next link 5 Bayer HealthCare makes no warranty of the performance of the CONTOUR NEXT LINK meter or test results when used with any control solution other than CONTOUR NEXT control solution 6 Bayer HealthCare makes no warranty of the performance of the CONTOUR NEXT LINK meter or test results when used with any software other than GLUCOFACTS DELUXE diabetes management software from Bayer where supported and CareLink Therapy Management software from Medtronic BAYER HEALTHCARE MAKES NO OTHER EXPRESS WARRANTY FOR THIS PRODUCT THE OPTION OF REPLACEMENT DESCRIBED ABOVE IS BAYER HEALTHCARE S ONLY OBLIGATION UNDER THIS WARRANTY IN NO EVENT SHALL BAYER BE LIABLE FOR INDIRECT SPECIAL OR CONSEQUENTIAL DAMAGES EVEN IF BAYER HEALTHCARE HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES For warranty service Purchaser must contact Bayer Customer Service for assistance and or instructions for obtaining service of this instrument Please see back cover for contact information AQUBLIEAA IWOINHOAL gt Z s 2 gt J m Index PGC ON ACY oc cccseante nes naenin 60 PAN GAS ae SA 10 Battery aos cececceasetdesawetssccaaveaseseceswacuccads 55 High Low Blood SuQatr cccee
32. any meter updates or GLUCOFACTS DELUXE updates e To order parts contact Bayer Customer Service Please see back cover for contact information References 1 Wickham NWR Achar KN Cove DH Unreliability of capillary blood glucose in peripheral vascular disease Practical Diabetes 1986 3 2 100 2 Atkin S et al Fingerstick Glucose Determination in Shock Ann Intern Med 1991 114 1020 1024 3 Desachy A Vuagnat AC et al Accuracy of bedside glucometry in critically ill patients influence of clinical characteristics and perfusion index Mayo Clin Proc 2008 83 4 400 405 4 American Diabetes Association Standards of medical care in diabetes 2012 Diabetes Care 2012 35 Suppl 1 S11 63 5 Canadian Diabetes Association Clinical Practice Guidelines Expert Committee Canadian Diabetes Association 2008 clinical practice guidelines for the prevention and management of diabetes in Canada Can J Diabetes 2008 32 suppl 1 S30 6 Longo D L et al Harrison s Principles of Internal Medicine 18th Edition 2011 http www accessmedicine com 7 Data on file Bayer HealthCare Diabetes Care 8 Tietz Fundamentals of Clinical Chemistry 5th Edition Edited by Burtis CA and Ashwood ER W B Saunders Co Philadelphia PA 2001 p 444 SOoUdIOJOY IWOINHOAL gt Z s 2 gt J m Warranty _l lt Z E O LUI H AND CARE Manufacturer s Warranty Bayer HealthCare warrants to the original purchaser
33. aot ie ar Level mmol L avanan K tes 0 28 mmol L 0 56 mmol L 0 83 mmol L 2 41 0 05 2 1 63 78 78 78 78 78 80 8 100 100 4 50 0 11 2 4 0 Table 2 System accuracy results for CONTOUR NEXT LINK et ws ced meter using CONTOUR NEXT test strips at glucose concentration 11 46 0 14 1 2 gt 4 2 mmol L 18 34 0 35 1 9 5 10 15 20 Principles of the Procedure 402 522 518 522 522 522 522 522 The CONTOUR NEXT LINK blood glucose test is based on 77 0 99 2 100 100 measurement of electrical current caused by the reaction of the glucose with the reagents on the electrode of the strip y Acceptance criteria in ISO 15197 2003 are that 95 of all The blood sample is drawn into the tip of the test strip through D differences in glucose values i e between reference method capillary action Glucose in the sample reacts with FAD glucose 2 T and meter should be within 0 83 mmol L for glucose dehydrogenase FAD GDH and a phenothiazine derivative as o lt values less than 4 2 mmol L and within 20 for glucose a mediator Electrons are generated producing a current that values greater than or equal to 4 2 mmol L is proportional to the glucose in the sample After the reaction time the glucose concentration in the sample is displayed No calculation is required l lt Z E 8 LUI H AND CARE IWOINHOAL gt Z J 2 gt J m Contour ry next link 60 Comparison Options The C
34. ark by pressing the OK button when your selection is highlighted Scroll down to NOTE see No Mark e Your test result does not display until you make an AutoLog selection e If your result is above or below your High or Low Alert settings you will see your result without pushing a button Th eee If Always was selected in Send Options during Setup 3 Send your result is automatically p sent to your pump If Never was selected in Send Options you will not have the option to send the result to your pump If ask Me was selected in Send Options you can choose to send your result to your pump after each blood sugar test Press Send or Don t Send If Send is chosen press OK on the Send confirmation screen You can change your send option at Before Meal Don t Send 99 any time using the Setup Menu see page 42 a WARNING e Do not calculate a bolus based on an AST result e Do not calibrate your continuous glucose monitoring device from an AST If you are done remove the test strip from the meter Press and hold the top Menu button to turn off the meter The meter also turns off after 3 minutes of inactivity Removing the Used Lancet 1 In one hand hold the lancing device with your thumb on the grip indent with your other hand hold the endcap as shown and gently snap off the endcap 2 Place the round protective lancet cap on a flat surface with the Bayer logo facing down 3 With the used lancet
35. elease button CI T N 5 Maintain steady pressure until a gt a small round blood drop forms EJ A 6 Lift the device straight up and away from the skin without smearing the blood 7 Test immediately after you have formed a small round blood drop Immediately touch the tip of the test strip to the drop of blood The blood is pulled into the test strip through the tip Do not test the blood sample from palm if you get e Smeared blood e Clotted blood e Runny blood e Clear fluid mixed with the blood 8 Hold the tip of the test strip in the blood drop until the meter beeps Do not press the tip against the skin or place the blood on top of the test strip or you could get inaccurate results or errors m Z Q Huns L S nyeu yy 104 doq poojg e Buriya 2 U LUI H Getting a Blood Drop for Alternative Site Testing If the first blood drop is not enough the meter will beep twice and display STRIP UNDERFILLED and APPLY MORE BLOOD NOW You have about 30 seconds to apply more blood to the same strip STRIP UNDERFILLED l If you do not apply more Remove used strip blood within about 30 Repeat test with new seconds remove the strip Strip and repeat with a new strip AUTOLOG If you have the AutoLog io feature turned ON the Before Meal AutoLog screen appears After Meal Select Fasting Before No Mark Meal 3 After Meal or No M
36. emia diabetic ketoacidosis and occurrence of severe dehydration are examples of clinical conditions that may adversely affect the measurement of glucose in peripheral blood 3 Keep out of reach of children This kit contains small parts which could cause suffocation if accidentally swallowed Contour ry next link Talk to Your Health Care Professional Before setting any Target ranges or High or Low Alerts on your meter Before changing your medication based on test results If your blood sugar reading is under 2 8 mmol L follow medical advice immediately If your blood sugar reading is over 13 9 mmol L wash and dry your hands well and repeat the test with a new strip If you get a similar result call your health care professional as soon as possible About whether Alternative Site Testing AST is appropriate for you Potential Biohazard Always wash and dry your hands well with soap and water before and after testing handling the meter lancing device or test strips The meter lancing device and lancets are for single person use only Do not share them with anyone including other family members Do not use on multiple persons All parts of this kit are considered biohazardous and can potentially transmit infectious diseases even after you have performed cleaning and disinfection For instructions please see Cleaning and Disinfection page 66 The MICROLET 2 lancing device is intended for self testing by a sing
37. g Symbol What It Means Symbol What It Means Use by date 29 last day of month Recycle Packaging LoT Batch code mfn c Control Range Normal y Temperature Control Range Low t MAAN E Control Range High Consult instructions Do not reuse for use In Vitro Diagnostic Sterilized using IVD STERILE R R Medical Device gt irradiation Catalogue number N Caution Symbol What It Means Batteries must be disposed of in accordance with laws in your country Contact your competent local authority for information on the relevant laws regarding disposal and recycling in your area The meter should be treated as contaminated and disposed of according to local safety rules It should not be disposed of with waste electronic equipment The USB cable is waste electrical and electronic equipment Do not dispose in household waste Remember to respect local regulations Contact your health care professional or local waste disposal authority for medical waste disposal guidelines Contour ry next link System Specifications Test Sample Capillary whole blood Test Result Referenced to plasma serum glucose Sample Volume 0 6 uL Measuring Range 1 1 mmol L to 33 3 mmol L Countdown Time 5 seconds Memory Stores most recent 1 000 test results Battery Type Non serviceable 250mAh rechargeable lithium polymer battery 3 4V 4 2V 5V input voltage Meter Battery Life 5 years Charging Current
38. he A or V button to scroll through the choices e Press OK when your choice is highlighted NOTE If the highlight is over an item that has previously been selected you will see a red X instead of OK Your meter has a lighted test strip port to help you test in the dark e With the meter off give the top Menu button two quick presses to turn on the test strip port light e Insert a test strip and the display screen appears e Once blood is applied to the test strip the light goes off e Continue with your test e Two quick presses of the top Menu button also turns off the light Contour RY next link Control Solution Testing WARNING Shake the control solution well before testing CAUTION Use only CONTOUR NEXT control solution from Bayer Normal Low and High with your CONTOUR NEXT LINK blood glucose monitoring system Using anything other than CONTOUR NEXT control solution can cause inaccurate results Quality Control You should perform a control test when e using your meter for the first time e you open a new bottle or package of test strips e you think your meter may not be working correctly e you have repeated unexpected blood glucose results AN WARNING e Do not calibrate your continuous glucose monitoring device from a control result e Do not calculate a bolus based on a control result CAUTION Check the expiry date on the test strip bottle and the expiry
39. ion process cE SETUP The current settings in the CONNECT TO PUMP 5 Press OK to begin the meter for the Reminder Connect to a MiniMed connection process Reminder eae Date Time Sound and Pump ees NOTE Pump refers late futolog can be viewed Go Back to your compatible O Time by scrolling through the Medtronic device 5 Saund Setup Menu items To z Autolog view the settings of the Q Target other items or to make 2 Trends Range any changes to any of the CONNECT TO PUMP 6 STOP Do NOT press High and Low Alerts items you can select the Enter this Meter ID lan ANY buttons ens item using the amp and Liat your Pump Fe z This screen displays the z a Ea keys and pressing OK leata Ro Back meter ID number in the cy o a 5 Pump Options allows you to connect to a Medtronic pump and Put down your meter S 2 change your Send Settings how your blood sugar readings are Pick up the compatible 3 sill ce taal Medtronic device and Connecting the Meter and Pump continue with Step 7 You can send blood sugar results to your pump if your meter and pump are connected 7 Press ACT to go to the MAIN MENU Scroll to Utilities by pressing the down arrow Press ACT 1 Press and hold the top Menu button to turn the meter on 2 Press the button next to Setup Lu pm O rs 2 MAIN MENU lt c gt GD lt 5 aie 2L cm SETUP 3 Press OK to select Pump Options Reminder Date Contour 38 next link 39
40. ir 3 Clear Endcap for AST cccccseeeees 3 Grey Endcap for Fingertip Testing 3 Error DISplayS xcasncctcccncctcecseasaccinaccendts 55 Fingertip Testing wiiccccvccsisscsescasncccevers 15 High and Low Allerts cccccceeees 10 Setting cetcaavtvesersapeesantesaausascinecssssainisaet 10 When Testing iccisasetnentadaentnansesaneiaanauias 25 High or Low Blood Sugar 25 PUTS ose acre e eat asaencsaeneeee 10 SyYMpPtOMS wink teecaaotinsecaasntanectudvonitesiad 59 Initial SOT icin sscsiacincaacaadeseaeicnasdandonsste 5 NANA OE E E PEE E A EE T 3 NSS S Assess asics cinesecnnmnctwascdmmetanexoess 23 Insert LANCEL ccceseccesesseeseeseeeeeaees 13 Remove Used Lancet cccceee 23 Lancing Device xd cusiscessuaveotnariecntsaies 3 Oe ai o er ee eee ne ee 3 USE e E EE 13 LUNN s esrinernciaanineininaaiin ennei 6 Light on Test Strip Port 06 4 Link Meter and Pump 0008 38 Logbook Memory ccccceeessseeeeees 35 Adding Entries Notes 000sc00 34 Reviewing 2 cceeeeeeeeeeceeeereeeeeeneeeees 35 Low and High Blood Sugar Results 08 25 Low or High Blood Sugar SyMptoMmS aise cecricisisenuncieteeiscseuannices 59 Main NSN atid we can testorinesaauanaiecnnenndbtes 35 LOODOOK Genre er er eee i ete 35 RSL co ccaseesanvacuastenreevasseheGuueeiemeue 38 MGTUCS 5 occc sch osessssnessunttsctiaucegdasiecouaneescee 36 Meal
41. is completed and saved to the Logbook A sound indicates the last entry 1 To review entries in the Logbook press and hold the top Menu button to turn the meter on 2 Press the button next to Logbook LOGBOOK 3 You can scroll through all your stored test results using the W button morris 11 06 09 k 10 30AM Sent Before Meal END OF LOGBOOK When you reach the oldest entry you will see the End of Logbook screen 4 amel 41 05 09 2 11 24AM Sent After Meal 35 yooq o lt c Pn lt 5 aie 2z I cm Viewing Trends With AutoLog Off USING THE MAIN MENU Trends Averages and Summaries The Trends feature displays your averages and your results as they compare to your Targets over a period of time that you select The options available are 7 14 30 and 90 day averages Your meter has been preset to 14 day averages but you can change this under Trends Range in the Setup Menu see page 51 Your 90 day average is not intended to be reflective of your HbA1c result Your screen will display the total number of test results included in the average and the number of tests above within 4 and below Target Viewing Trends With AutoLog Off Your meter has been preset to 14 day averages You can change the Trends time range to 7 30 or 90 days in Setup 1 Press and hold the top Menu button to turn the meter on 2 Press the button next to Trends TRENDS TARGET 3 9 72 3 P
42. is providing testing assistance the meter and lancing device should be disinfected prior to use by the second person The cleaning and disinfecting directions provided will not cause any damage or degradation to the external case buttons or display Your CONTOUR NEXT LINK meter and MICROLET 2 lancing device have been tested for 260 cycles of cleaning and disinfection one cycle per week for 5 years These devices have been demonstrated to withstand 5 years of cleaning and disinfection without damage You should call Bayer Diabetes Care Customer Service for assistance if your device malfunctions for any cause or if you notice any changes in the meter case or display For more information see FDA Public Health Notification Use of Fingerstick Devices on More than One Person Poses Risk for Transmitting Bloodborne Pathogens Initial Communication 2010 http www fda gov Medical Devices Safety AlertsandNotices ucm224025 htm Cleaning Your Meter Supplies Needed for Cleaning e Germicidal wipes containing 0 55 sodium hypochlorite bleach Paper towels Carefully clean the meter with germicidal wipes until all soil is removed Do not allow cleaning solution to run into the meter through areas such as around the buttons or the meter s test strip or data ports 2 Dry as necessary with a clean paper towel A uoo zuis qg pue Hulues y IWOINHOAL gt Z s 2 gt J m Cleaning and Disinfection _l lt
43. ith correct glucose results from your Bayer strip meter to CareLink Therapy Management software You can also wirelessly transfer e f there is an error hardware software testing errors data from your compatible detected by your meter your meter will beep twice pump to CareLink Therapy Management software using your e You will see specific instructions to guide you The first line of CONTOUR NEXT LINK meter the error screen will tell you the error The next lines describe 1 Refer to the CareLink Therapy Management software user what you should do When an error screen displays an OK guide for instructions on how to set up CareLink and load press the button next to it to continue the required drivers onto your computer e f you do not resolve the problem contact Bayer Customer 2 If you are running GLUCOFACTS DELUXE diabetes Service Please see back cover for contact information management software from Bayer on your computer you must close it Battery Status 3 Start up CareLink Follow the instructions to plug your CONTOUR NEXT LINK meter into a USB port on Battery Status Displays your computer CareLink will automatically find the The battery status is displayed with a battery symbol E on CONTOUR NEXT LINK meter and your compatible pump the Apply Blood screen and the Main Menu screen It shows Your CONTOUR NEXT LINK meter is also compatible with how much battery life is left GLUCOFACTS DELUXE diabetes management sof
44. izziness N WARNING If you are experiencing any of these symptoms test your blood sugar If your test result is under 2 8 mmol L or above 13 9 mmol L contact your health care professional immediately For additional information and a complete list of symptoms contact your health care professional Jens poojg mo 10 UbIP jo swozdwAsg IWOINHOAL gt Z s 2 gt J m Technical Information Precision Accuracy A repeatability study was conducted with the The CONTOUR NEXT LINK blood glucose monitoring system CONTOUR NEXT LINK blood glucose monitoring system using was tested in 100 capillary blood samples using 600 five venous whole blood specimens with glucose levels from CONTOUR NEXT test strips Two replicates were tested with 2 4 to 18 2 mmol L Multiple replicates n 100 per lot were each of 3 lots of CONTOUR NEXT test strips for a total of 600 tested using multiple CONTOUR NEXT LINK blood glucose readings Results were compared to the YSI glucose analyzer meters and 3 lots of CONTOUR NEXT test strips The following which is traceable to the CDC hexokinase method The tables precision results were obtained below compare the performance of the two methods System repeatability results for CONTOUR NEXT LINK meter Table 1 System accuracy results for CONTOUR NEXT LINK using CONTOUR NEXT test strips meter using CONTOUR NEXT test strips at glucose concentration lt 4 2 mmol L Mean Cluccse Shari Coefficient of
45. le patient It must not be used on more than one person due to the risk of infection Use a new MICROLET lancet each time you test because it is no longer sterile after use Always dispose of test strips and lancets as medical waste or as advised by your health care professional All products that come in contact with human blood should be handled as if capable of transmitting infectious diseases PRECAUTIONS e i Read your CONTOUR NEXT LINK user guide the MICROLET 2 lancing device package insert your Medtronic device user guide and e Use only approved cables or wall charger from the manufacturer or a 5V charger approved by a certified body such as UL TUV or CSA e The CONTOUR NEXT LINK meter from Bayer has been preset and all instructional materials provided in your meter kit before testing Please follow all instructions for use and care exactly as described to help avoid inaccurate results Examine product for missing damaged or broken parts If the test strip bottle is open inside a new box of strips do not use those strips For replacement parts contact Bayer Customer Service Please see back cover for contact information The CONTOUR NEXT LINK meter from Bayer only works with CONTOUR NEXT test strips and CONTOUR NEXT control solutions Always keep the CONTOUR NEXT test strips in their original bottle Tightly close the bottle immediately after removing a test strip The bottle is designed to keep the test strip
46. ll appear in the Setup and Main Menu headers NOTE If you decide to test within 15 minutes before the reminder time the countdown stops when you insert a test strip Turning Off a Reminder To turn off a reminder you can use the Setup Menu or do a blood sugar test within 15 minutes of the reminder time To use the Setup Menu 1 Press and hold the top Menu button to turn the meter on 2 Press the button next to Setup O SETUP T k 3 Press the y button to highlight Pump Options Reminder On Press OK to turn lt Jai d the Reminder OFF C 4 Select Stop A REMINDER IM confirmation D 20 Change screen appears hrs mins Go Back and the countdown i y stops E Contour ry next link SETUP Pump Options 5 Reminder is now off Date Date and Time Setting or Changing the Date 1 Press and hold the top Menu button to turn the meter on 2 Press the button next to Setup SETUP 3 Press the V button to Reminder highlight Date Press Ok to select Time DATE mmddyy 4 To change the date press Change 10 13 10 Go Back 5 Select either format Month Day Year or Day Month Year M ont hiDa y Hear Da y Month Year CRNE 6 Press the A or W button CHANGE MERR Mek lo to select the correct year 10 13 month and day Press 0k v after each selection Date is set 10 13 11 7 A screen confirms the date you entered Press Done if the date is correct
47. mediately If your blood sugar reading is over 13 9 mmol L wash and dry your hands well and repeat the test with a new strip If you get a similar result follow medical advice immediately Always consult your health care professional before changing your medication based on test results High and Low Blood Sugar Alert Screens Your meter has been preset with a low blood sugar hypoglycaemia value of 3 9 mmol L and a high blood sugar hyperglycaemia value of 13 9 mmol L These are the preset values but can be customized by you and or your health care professional You can change the High and Low Alert levels under Main Menu Setup option see page 52 If your blood sugar reading is under your low blood sugar alert level e A screen with large orange numbers alerts you that your blood sugar is low If your blood sugar reading is over your high blood sugar alert level e Ascreen with large orange numbers alerts you that your blood sugar is high 25 m Z Q su 19 Lay JeHNS poojg mo pue yH 9 U Lu H Testing in the Dark 14 36 AM 18 11 Reminder Hotes ADD NOTES Before Meal i Don t Feel Right Sick Stress Activity Go Back ADO NOTES Before Meal t Y Don t Feel Right sick Stress Activity Go Back Testing in the Dark e f AutoLog is ON and you did not mark your result before the high or low alert appeared select Notes e Press t
48. note is available only after a test result 1 From the test result screen press Notes 2 Press the A or V button to scroll through the choices Some may not be visible until you scroll down Press 0K when your choice is highlighted A screen confirms AOD NOTES co Fasting 7 After Meal Don t Feel Right sick your choice NOTE AOD NOTES e If the highlight is over an Before Meal item that has previously wo been selected you will i rar Maz see a red X instead of Don t Feel Right OK sick e When you choose After Stress Meal Time After Meal Activity will become selectable Go Back Select Time After Meal and then you can select times from 15 minutes to 3 hours After the confirmation screen disappears you may remove the note or add one or more notes by repeating the steps above The notes will scroll across the bottom so that you can read them all While you can add more than one note only one AutoLog option can be chosen e g Fasting Before Meal or After Meal Contour ry next link 34 Using the Main Menu The Main Menu has three choices Logbook Trends and Setup Select one by pressing the button next to your choice Logbook Trends getup Logbook The Logbook contains blood sugar test results and notes that you have made to those test results The Logbook will hold up to 1 000 results When the maximum is reached the oldest test result will be removed as a new test
49. ow buttons to enter the six character meter ID shown on the meter screen Press ACT after each character entry N o P J _ ma J 0 dwnd 0 Wauuoy GETTING STARTED Meter Send Options 8 13 Select Review ID on your compatible Medtronic device to confirm that your CONTOUR NEXT LINK meter ID has been correctly entered If incorrect go back to Step 10 NOTE For detailed instructions see your compatible Medtronic device user guide 14 Return to your CONTOUR NEXT LINK meter After you have entered the meter ID into your compatible Medtronic device press Mert CONNECT TO PUMP Enter this Meter ID _ into your pump Nent 123456 Go Back Meter Send Options 15 After the meter and pump are connected you set your Send Options This controls how your meter sends blood glucose readings to your Medtronic pump Your options are always Meter will always send results Ask Me Meter will ask you before sending results Never Meter will never send results Contour ry next link SEND OPTIONS Automatically send Always results to the Pump Neyer Send Options set Meter will ask you before sending results Ask me Press the Send Option that is best for you Your choice can be changed later using Setup See page 42 16 Press OK Set Date and Time to Match Medtronic Device aL G E Fii ALT 4 a CURRE IT DATE amp TIME
50. plete instructions If you are using a different lancing device see that manufacturer s instructions for use For Alternative Site Testing instructions see page 19 1 Remove the endcap from the MICROLET 2 lancing device with your thumb on the grip indent as shown Snap the endcap off from top 13 to bottom m lt Q 901A0qg Huldue y Buned ld TESTING Preparing the Test Strip Preparing the Test Strip Loosen the round protective cap on the lancet by rotating it turn but do not remove it Always use MICROLET lancets for the best operation Insert the lancet firmly into the lancing device until it comes to a full stop This will re set the device You can also pull and release the re setting handle Twist off the round protective lancet cap Save it for disposing of the used lancet Replace the grey endcap before getting blood drop The puncture depth depends on the endcap setting and the amount of pressure applied to the puncture site Rotate the endcap dial to adjust the puncture depth VAN WARNING Always wash your hands with soap and water and dry them well before and after testing handling the meter lancing device or test strips Remove a CONTOUR NEXT test strip from the bottle Tightly close the bottle lid immediately after you have removed the test strip 2 Hold the test strip with the grey square end facing up 3 Inse
51. proved by a certified body such as UL TUV or CSA Bbuibieyy Aioyeg J vo CNV IWOINHOAL End of Meter Life Battery Removal _l lt Z E 8 LUI H AND CARE End of Meter Life Battery Removal NOTE Carry out this process only when you no longer intend to use the meter Meter will not be functional once opened to remove the battery To remove the battery for proper disposal you will need to pry the upper and lower cases apart With a screwdriver beginning near the strip port insert the tip of the screwdriver and twist to pry the case loose Continue to do this down the side until the upper case comes apart Pry up rechargeable battery here A Disconnect battery by pulling battery connector B Dispose of the meter and lithium polymer battery in accordance with your local country laws and regulations Contour ry next link Symptoms of High or Low Blood Sugar You can better understand your test results by being aware of the symptoms of high or low blood sugar Some of the most common symptoms are Low blood High blood Ketones sugar sugar Ketoacidosis Hypoglycaemia Hyperglycaemia Shakiness Frequent o Shortness of Sweating Urination Breath Fast Heartbeat Excessive Thirst Nausea or Blurred Vision Blurred Vision Vomiting Confusion Increased e Very Dry Passing Out Fatigue Mouth Irritability Hunger Seizure Extreme Hunger D
52. ress the V button to display the 14 Day id DAY RESULTS ee Results screen AVERAGE mmal 45 Jagung ag iCal ee Contour ry next link Viewing Trends With AutoLog On 1 Press and hold the top Menu button to turn the meter on 2 Press the W button to highlight Trends Press 0K to select 3 Press the V button to display the 14 Day Fasting 71 mmal BQ i Average If you have ot E marked any test results as Fasting you will see your Fasting Average first id DAY BEFORE MEAL 4 Press the W button to go AVERAGE s to the 14 Day Before Meal 71 snl 4 Average 14 OAY FASTING AVERAGE This example shows that your Before Meal average is 7 1 mmol L and 38 test results are included in the Before Meal average with 26 within 4 the Target range 8 above the Target range and 4 below amp the Target range 14 DAY AFTER MEAL areas 5 Press the W button to go O Te pen to the 14 Day After Meal Average 14 DAY RESULTS AVERAGE 6 Press the V button to go to the 14 Day Results screen mmol Results Ley uo Boo y Ny YUM SpU IL BuIMelA Sc Pn Zg n 2L cm Setup PUMP OPTIONS end Options You can view and change options on your meter and personalize it from the Setup Menu 1 Press and hold the top Menu button to turn the meter on 2 Press the button next to Setup Connection 4 Press Connection bottom left corner This ID is needed to complete Pump Options the connect
53. rget ranges on your meter Changing Targets With AutoLog Off When AutoLog is OFF you have only one Target range It comes preset to 3 9 10 0 mmol L NOTE Targets can only be set inside your selected Alert level s For additional information you may contact Customer Service Contact information for Customer Service is on the back cover 1 Press and hold the top Menu button to turn the meter on 2 Press the button next to Setup SETUP HutoLlog 3 Press the VW button to highlight Target Press OK Trends Range to select TARGET 4 To make changes to Accept your Target range 3 9 10 0 press Change Change sjobuey seins poojg Sc Pn lt 5 aie 2z I cm Changing Targets With AutoLog On Lu pm 2 ie V MAIN MENU 5 Use the A or V button to change each value of the Target Press 0K after each selection Target is set A screen confirms 42 400 your choice Changing Targets With AutoLog On When AutoLog is ON your CONTOUR NEXT LINK meter comes preset with the following Target ranges for testing Fasting 3 9 7 2 mmol L ry Before Meal 3 9 7 2 mmol L EJ After Meal 3 9 10 0 mmol L Ranges can be changed to personal Targets decided by you and or your health care professional NOTE Targets can only be set inside your selected Alert level s For additional information you may contact Customer Service Contact information for Customer Service i
54. rns off after 3 minutes of inactivity Using the Top Menu Button The top Menu button has three functions e To turn the meter on off press and hold the top Menu button e To go back one screen from most screens press the top Menu button once e To turn on off the test strip port light quickly press the top Menu button two times Using the Selection Scrolling Buttons A Button 0K Button Vv Button e The three buttons next to the screen allow you to make your selection by pressing the button next to your choice e Scroll up or down for additional choices when the A or V arrows appear on the meter screen Contour ry next link e When your choice is highlighted make a selection by pressing OK NOTE Press and hold the A or V button to scroll through the list faster Using the Main Menu com MENU The Main Menu has three choices Logbook Trends and Setup Select one by pressing the button next to your choice CAUTION Unplug meter from charging source before beginning Setup Initial Setup 1 Before use fully charge your meter See page vi 2 Press and hold the too Menu button until the meter turns on After a welcome screen you see the Language choice screen a Jo gt J s ma o 0 dnjas emul oa Z ul ro F lt LL j On Set Language Set Language These meter screen images are for illustration purposes only LANGUAGE 3 Press the V button to
55. rt the grey square end into the test strip port until the meter beeps if the Sound is set to ON APPLY BLOOD You will see the Apply Blood screen The meter is now ready for you to test NOTE After test strip is inserted if you do not apply blood to the test strip within 1 minute the meter screen will dim and the meter will beep Press any button and the Apply Blood screen will become bright again After a total of 3 minutes of inactivity the meter will turn off Getting the Blood Drop Fingertip Testing 1 Press the endcap firmly against the puncture site and press the blue release button with your thumb 2 Stroke your hand and finger toward the puncture site to form a drop of blood Do not squeeze around the puncture site 9 m Z Q Hulsey diebuly doig poojg y buljyjey5 2 T Y LUI H Apply More Blood 16 3 Test immediately after a good drop of blood has formed 4 Immediately touch the tip of the test strip to the drop of blood The blood is pulled into the test strip through the tip Hold the tip of the test strip in the blood drop until the meter beeps Do not press the tip against the skin or place the blood on top of the test strip or you could get inaccurate results or errors Apply More Blood STRIP UNDERFILLED If the first blood drop is not enough the meter will beep twice and display STRIP UNDERFILLED and APPLY M
56. s dry Avoid exposing meter and test strips to excessive humidity heat cold dust and dirt Exposure to room humidity from leaving the bottle open or not storing the strips in their original bottle can damage your test strips This could lead to inaccurate results Do not use a test strip that appears damaged or has been used Check the expiry dates on your test strips and control solution Do not use the test strips or control solution if the expiry date printed on the bottle label and carton has passed This can cause inaccurate results For the control solution do not use if it has been 6 months since you first opened the bottle After first opening the bottle write the 6 month discard date on the control solution label If your control solution test result is out of range contact Bayer Customer Service Please see back cover for contact information Do not use the meter for blood glucose testing until you resolve this issue The meter has been designed to give accurate results at temperatures between 5 to 45 C If you are outside this range you should not test Whenever the meter is moved from one location to another allow approximately 20 minutes for the meter to adjust to the temperature of the new location before performing a blood glucose test Do not perform a blood glucose test when the CONTOUR NEXT LINK meter is connected to a computer IV locked to display results in mmol L millimoles of glucose per litre of blood
57. s on the back cover 1 Press and hold the top Menu button to turn the meter on 2 Press the button next to Setup SETUP AutoLog 3 Press the Y button to highlight Target Press OK Trends Range to select TARGET Fasting De E 4 To make changes to your Fasting Target range press Change otherwise press Accept Accept Change Contour ry next link TARGET 5 Press the A or V button to select your desired 73 Fasting Targets Press 0K at e after each selection Fasting 6 Repeat this process to set your personal Before Meal Targets and After Meal Targets 7 Press OK after each selection Targets are set 23 4 7 2 AE 39 10 0 Umi 39 100 Change A screen confirms that all Target ranges are set If correct press Done to return to the Setup Menu To make changes press Change and repeat the process Trends Range The Trends feature displays your averages and your results as they compare to your Targets over a period of time that you select The options available are 7 14 30 and 90 day averages Your meter has been preset to 14 day averages but you can change this in Setup 1 Press and hold the top Menu button to turn the meter on 2 Press the button next to Setup SETUP Target 3 Press the W button to highlight Trends Range High and Low Alerts 4 Press OK to select TRENDS RANGE CURRENT SETTING 5 Your current setting is displayed You can Accep
58. see at more language choices Deutsch When your language is Espa ol highlighted press OK Language English 4 Press OK to confirm If the correct language is not displayed press No Connect to Pump CONNECT TO PUMP 5 If you are connecting to ini Connect to a MiniMed SES orev Pump If not press SKIP and go to Step 17 NOTE Pump refers to your compatible Medtronic device CONNECT TO PUMP Enter this Meter ID a into your Pump dent 123456 Go Back 6 STOP Do NOT press ANY buttons This screen displays the meter ID in the bottom left corner This ID is needed to complete the connection process Put down your meter Pick up the compatible Medtronic device and continue with Step 7 7 Press ACT to go to the MAIN MENU Scroll to Utilities by pressing the down arrow Press ACT press 0K and go to Step 6 8 Scroll to Connect Devices and press ACT Then scroll to Meters and press ACT NOTE If your UTILITIES MENU does not contain Connect Devices scroll to Meter Options and press ACT 9 Select n and press ACT If you are replacing a meter go to Step 10 If you are adding a new meter go to Step 12 10 To replace a meter select Delete ID and press ACT 11 If you have multiple meter IDs repeat Step 10 for each one 12 To add a new meter select Add ID and press ACT Refer to Step 6 or see meter back to find meter ID SN Use the up and down arr
59. ss the button next to Setup Contour 46 next link 47 AutoLog Lu pm 2 ie V MAIN MENU SETUP snd 3 Press the V button to highlight AutoLog Press OK to select Target AUTOLOG AutoLog is Off 4 Press Turn On to activate AutoLog AutoLog is On A screen confirms your choice NOTE e When you change your AutoLog setting to ON you are asked to confirm your Target settings for Fasting Before Meal and After Meal e Your test result does not display until you make an AutoLog selection e If your result is above or below your High or Low Alert settings you will see your result without pushing a button To Turn Off AutoLog NOTE Your meter comes with AutoLog OFF 1 Press and hold the top Menu button to turn the meter on 2 Press the button next to Setup Q SETUP Sound 3 Press the VW button to highlight futaLog Press OK to select Target AUTOLOG 4 To turn AutoLog OFF press Turn Off AutoLog is On Accept Turn Off Autolog is Off A screen confirms your choice NOTE When you change your AutoLog setting to OFF you are asked to confirm your Target setting Blood Sugar Targets Targets are your personal ranges for your blood sugar results With AutoLog OFF you have a single Target range With AutoLog ON you have Target ranges for Fasting Before Meal and After Meal A WARNING Talk to your health care professional before setting any Ta
60. stece 55 Technical INTOrnmatON cn 2axssczccctsansastactoaceanuasteesnccsaeveseecenscesieuesses 60 Caring for Your Meter sn ssnsssnsnenesensennsrrrnesrnrennsrrnrrrnrrnrenne 66 Cleaning and Disinfection ssseeeesnneneerrsenrrrrrrerrnrresrenrenn 66 WV IPTC eea I E 72 GALYVLS ONILLAD ONILSAL TI gt C JJ m NNAW NIVIN AHL ONISN J vo GNV IWOINHOAL oa Z ul H ey F lt W j On The CONTOUR NEXT LINK Wireless Blood Glucose Monitoring System from Bayer Getting Started The CONTOUR NEXT LINK Wireless Blood Glucose Monitoring System from Bayer The CONTOUR NEXT LINK wireless blood glucose monitoring system from Bayer works with CONTOUR NEXT test strips from Bayer Top Menu Button See page 4 Display Screen Meter USB Plug 12 00 PM 118 15 D 2 Reminder Before Meal Notes Test Strip Port Selection Scrolling Insert the test strip here Buttons To turn on the test strip See page 4 port light see page 4 AN WARNING Protective USB Cap Keep out of reach of children Accidental swallowing could cause suffocation Your CONTOUR NEXT Test Strip Grey Square End 7 4 Insert this end into the test strip ALD port with the grey end facing up Cy Sample Tip Blood sample pulled in here CAUTION The CONTOUR NEXT LINK meter from Bayer only works with CONTOUR NEXT test strips and CONTOUR NEXT control solutions Contour ry next link Your MICR
61. still in the lancing device push the lancet needle completely into the middle of the exposed side of the cap 4 While pressing the release button a pull the re setting handle b and the lancet will drop into the container you have selected uN WARNING e Dispose of the used lancet as medical waste or as advised by your health care professional Do not reuse lancets Use a new MICROLET lancet each time you test m Z Q 9 ue7 p sn y BulAowsy 2 a Y Lu H Test Results Expected Values 24 AN WARNING Potential Biohazard e Always dispose of test strip and lancet as medical waste or as advised by your health care professional All products that come in contact with human blood should be handled as if capable of transmitting infectious diseases Please refer to your MICROLET 2 package insert for instructions on how to properly remove and dispose of the lancet Test Results Expected Values Blood glucose values will vary depending on food intake medication dosages health stress or activity Non diabetic plasma glucose concentrations are normally maintained within a relatively narrow range approximately 3 9 6 1 mmol L in a fasting state Contour R next F A ly AN WARNING You should consult your health care professional for glucose values specific to your needs e If your blood sugar reading is under 2 8 mmol L follow medical advice im
62. sult to your pump after each blood sugar test Press Send or Don t Send If Send is chosen press 0K on the Send confirmation screen Leave the test strip in the meter to set a reminder for your next test See page 31 or add a note see page 34 930 Before Meal Don t Send 14 36 AM 14 11 3 Reminder y After Meal Hotes If you are done remove the test strip To turn off the meter press and hold the top Menu button Or after 3 minutes of inactivity the meter turns off automatically CAUTION Always check the display on your pump to ensure that the glucose result shown agrees with the glucose result shown on the meter Alternative Site Testing AST Palm WARNING e Ask your health care professional if Alternative Site Testing is right for you e Do not calibrate your continuous glucose monitoring device from an AST result e Do not calculate a bolus based on an AST result IMPORTANT For Alternative Site Testing use the clear endcap on your lancing device Your CONTOUR NEXT LINK meter can be used for fingertip or palm testing See the MICROLET 2 insert for complete instructions in Alternative Site Testing m Z Q wed LSY Buns L S neuI yy 2 m Y Lu H Getting a Blood Drop for Alternative Site Testing 20 IMPORTANT Do not use AST under the following conditions e f you think your blood sugar is low e When blood sugar is changing rapidly after
63. t or Change your current setting We Ter Change NOTE Your 90 day average is not intended to be reflective of your HbA1c result 51 obuey spu IL Sc Pn lt 5 ae 2z IL cm High and Low Alerts TZ H W g 2 Zz V 5S TRENDS RANGE 6 Select 7 14 30 or 90 Day by using the W button and 14 Day then press OK KRIEL A screen confirms your 30 Day choice High and Low Alerts The High and Low Alerts tell you that your test result is above or below the setting you choose Alerts appear as large orange numbers Results above High are marked High Blood Sugar Results below Low are marked Low Blood Sugar NOTE Alerts can only be set outside your selected Target Range s For additional information you may contact Customer Service Contact information for Customer Service is on the back cover VAN WARNING Talk to your health care professional before setting any High or Low Alerts on your meter 1 Press and hold the top Menu button to turn the meter on 2 Press the button next to Setup SETUP 3 Press the V button to Trends Range highlight High and Low Alerts Press OK to select Language HIGH AND LOW ALERTS 4 Choose Accept to use the preset Alert levels or the Alert levels you chose during initial setup for High and Low Alerts The preset High Alert is 13 9 mmol L and the preset Low Alert is High 13 9 Accept Low 3 9 Change 3 9 mmol L Contour 5 Choose Change if you RA nex
64. t lets you mark your test result as gt Fasting Before Meal x After Meal and No Mark Your meter comes with AutoLog OFF If you would like to see your results when Fasting Before Meal or After Meal we recommend that you turn on this feature See page 47 AUTOLOG a e Before Meal wv After Meal Ho Mark If you have turned AutoLog ON in Setup before your test result is displayed the AutoLog screen appears However if your result is above your High Alert setting or below your Low Alert setting you will always see your result in 5 seconds without pushing a button Sending Results to Your Pump You can send your results to the pump during testing During Initial Setup Send Options or in Setup Pump Options Send Options choose Ask Me or Always lf Always was selected in mea Send Options during Setup JN your result is automatically Don t Send sent to your pump If Never was selected in Send Options you will not have the option to send the result to your pump If ask Me was selected in Send Options you can choose to send your result to your pump after each blood sugar test MOUR RESULTS Before Meal Press Send or Don t Send You can change your Send Option at 39 any time using the Setup Menu see page 42 CAUTION e You may want to test with Send Options set to Never if you do not want to create a wireless signal for example if you have been asked to turn off all electronic devices in
65. t li h wish to use different In Alert levels HIGH AND LOW ALERTS 6 Press the A or YV button High 13 9 to select your High and a Low Alert Press OK after DIA i Low each selection Alerts are set High 13 9 7 The next screen confirms your choices Press Done Low 3 8 set Language 1 Press and hold the top Menu button to turn the meter on 2 Press the button next to Setup These meter screen images are for illustration purposes only SETUP j 3 P the V button t High and Low Alerts ress the utton to highlight Language Press OK to select Customer Service LANGUAGE 4 Press the A or W button al to select the language Deutsch you prefer Press W to see Espanol more choices Press OK Language 5 Verify that the language English you selected is displayed Press OK to confirm If the correct language is not displayed press No Customer Service This option is to be used if you are speaking to a Bayer Customer Service representative They will give you a code that enables them to verify certain settings It is not for use any other time Please see back cover for contact information o6enbue712eS Sc Pn z 2L cm Technical and Care Error Detection Displays Transferring Data to Medtronic s CareLink e An error screen will always have an E with a number in the Therapy Management lower left corner of the display Software You can easily transfer blood Repeat test w
66. trip ssciwuscewarnccassuetinsssasasavensswes Your MICROLET 2 Lancing Device cccccssseeeeeeseeeeeeees Pa SN susanne T A iE Preparing the Lancing DeVICE cccssecessseteeseeeenaeeees 13 Getting the Blood Drop Fingertip Testing 0 15 Test Results sciteactontaitaaiiminineasicciineainean tatesiuccdauiveastdaabeas 17 Alternative Site Testing AST Palm ccccseeeeeeeees 19 Control Solution TESTING scccccsesseeeceeeseeeeseseeeeseaeees 27 AutoLog Marking Your Results cccccssseeeeeseeeeeeenes 30 Sending Results to Your PUMP cccccssseceecesseeeenseeees 30 Test Reminders cccsecccecceesceceeeeceeeeseeeeeeeseueeseeeeseeeeses 31 NOED aserra E E 34 LOQDOOK sic csiiasccnasecsaxonneess 35 SOU isorine 47 Trends Averages and PUTO LOG ssns 47 Summaries 022cee ee 36 Blood Sugar Targets 49 Setup ertaceauastvendeiosnesetseenes 38 Trends Range 51 Pump Options 006 38 High and Low Alerts 52 Meter Send Options 41 Set Language sinciacaorsseaceae 53 Test Reminders 0 0000 43 Customer Service 53 Date and Time 00 45 Transferring Data to Medtronic s CareLink Therapy Management Software cccccccssssceeseeseeeeeeseseeeessesseeesssees 54 Error Detection Displays isicsaieviosnenecasaislosuwntscsais fosnaeteconieiotuests 55 Battery ota S aner na ea ducercasmstaachascendnscss
67. tware from En i i i i ogboo Bayer which may not be available in all countries g This screen displays EER full battery IMPORTANT The CONTOUR NEXT LINK meter from Bayer Setup has only been tested for use with Medtronic s CareLink Therapy Management software and GLUCOFACTS DELUXE Transferring Data to Medtronic s CareLink Therapy Management Software sAe dsig uo01 99 q 10113 diabetes management software from Bayer Bayer is not responsible for any erroneous results from the use of other software For more information contact Bayer Customer Service Please see back cover for contact information Contour ry next link l lt Z E O LUI H AND CARE IWOINHOAL gt Z s 2 gt J m 54 Battery Status Displays _l lt Z E O LUI H AND CARE oa MENU Logbook As the battery is used gboo the battery symbol on the UHUH screen gradually shows less Setup fill colour The colour of the battery fill turns yellow when the battery is low and then red when your battery is almost out of charge A series of low battery alerts tell you that the battery is low and to Charge Soon Battery low If you do not charge the battery a display alerts you Shutting down Battery is dead You must charge immediately Battery is dead Plug the meter into your wall charger or into the USB port of your computer Be sure your computer is turned on and not in sleep
68. ustomer Service Contact information for Customer Service is on the back cover IS WARNING Talk to your health care professional before setting any Target ranges on your meter 23 If AutoLog is OFF Accept or Change the preset blood sugar Target range The preset range is 3 9 10 0 mmol L 3 9 10 0 11 2 U LUI H Getting Ready to Test TARGET If AutoLog is ON Accept Fasting or Change the preset blood m4ag 7a sugar range for Fasting Before Meal and After Meal screens Each Target has an option to Accept or Change NOTE As shown in the meter screen above the preset values of 3 9 7 2 are based on ADA recommendations The values based on Canadian Diabetes Association CDA recommendations are as follows D 4 0 7 0 mmol L 3 Before Meal 4 0 7 0 mmol L After Meal 5 0 10 0 mmol L 24 To change the Targets press the A or V button until the desired Target is reached and then press OK Press Accept on confirmation screen You can change these settings later by going to the Main Menu and selecting Setup See page 49 Setup is complete Initial Setup is complete Insert strip to start a You may now test Test your blood sugar See Testing below Testing Getting Ready to Test CE Read your CONTOUR NEXT LINK user guide your Medtronic device user guide the MICROLET 2 lancing device insert and all instructional materials provided in your meter kit