Home
Data Sheet - Thermal Engineering Lab
Contents
1. Characteristics Vertical System Analog Channels Characteristic MSO3012 DPO3012 Input Channels 2 Analog Bandwidth 3 dB 100 MHz Calculated Rise Time 3 5 ns 5 mV div typical Hardware Bandwidth Limits Input Coupling Input Impedance Input Sensitivity Range 1 MQ Input Sensitivity Range 75 Q 50 Q Vertical Resolution Maximum Input Voltage 1 MQ Maximum Input Voltage 75 O 50 Q DC Gain Accuracy Channel to Channel Isolation 20 MHz MSO3014 MSO3032 MSO3034 MSO3054 DPO3014 DPO3032 DPO3034 DPO3054 4 2 4 4 100 MHz 300 MHz 300 MHz 500 MHz 3 5 ns 1 17 ns 1 17 ns 700 ps 20 MHz 150 MHz AC DC GND 1 MQ 1 75 Q 1 50 Q 1 1 mV div to 10 V div 1 mV div to 1 V div 8 bits 11 bits with Hi Res 300 Vrus with peaks lt 450 V 5 Vrus with peaks lt 20 V 1 5 for 5 mV div and above 2 0 for 2 mV div 2 5 for 1 mV div 2100 1 at 100 MHz and 230 1 at gt 100 MHz up to the rated BW Any Two Channels at E qual Vertical Scale Offset Range Range 1 MQ 50 75 0 1 mV div to 99 5 mV div 1 V 1 V 100 mV div to 995 mV div 10 V 5 V 1 V div 100 V 5 V 1 01 V div to 10 V div 100 V NA Vertical System Digital Channels Characteristic All MSO3000 Models Input Channels 16 Digital D15 to DO Thresholds Threshold per set of 8 channels Threshold Selections TTL CMOS ECL PECL User Defned User defned Threshold 15 V to 25 V Range Maximum Input Voltage 20 V to 30 V Threshold Accuracy 1
2. Enables fast and easy communication between a Windows PC and the MSO DP 03000 Series Transfer and save settings waveforms measurements and screen images Included Word and Excel toolbars automate the transfer of acquisition data and screen images from the oscilloscope into Word and Excel for quick reporting or further analysis Provides a standard instrument programming interface for common applications such as LabVIEW LabWindows CVI Microsoft NET and MATLAB Enables control of the MSO DP03000 Series over a network connection through a standard web browser Simply enter the IP address or network name of the oscilloscope and a web page will be served to the browser Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 FAX 781 665 0780 TestEquipmentDepot com www tektronix com 13 Data Sheet Display Characteristics Characteristic Display Type Display Resolution Waveform Styles Graticules Format Maximum Waveform Capture Rate Input Output Ports Port USB 2 0 High speed Host Port USB 2 0 High speed Device Port LAN Port Video Out Port Auxiliary Input Probe Compensator Output Trigger Out Kensington Style Lock Power Source Characteristic Power Source Voltage Power Source Frequency Power Consumption Optional TekVPI External Power Supply Description 9 in 228 6 mm wide format liquid crystal TFT color display 800 horizontal x 480 vertic
3. The MS03000 Series has redefned the way you view digital waveforms One common problem shared by both logic analyzers and mixed signal oscilloscopes is determining if data is a one or a zero when zoomed in far enough that the digital trace stays fht all the way across the display The MS03000 Series has color coded digital traces displaying ones in green and zeros in blue www tektronix com 5 FAX 781 665 0780 TestEquipmentDepot com Data Sheet 200s 2 506575 D i T LOOK points lt 4 80N5 015 00 Maanivu el Timing Resolution 242p5 White edges indicate additional information is available by zooming in As shown here zooming in on the white edge reveals a hidden glitch 40 0ns 2 50GS S TL i yt 100k points lt 4 80ns PEN i gt Timing Resolution 121ps j The MagniVu high resolution record provides 121 2 ps timing resolution enabling you to make critical timing measurements on your digital waveforms The multiple transition detection hardware of the MS03000 Series will show you a white edge on the display when the system detects multiple transitions White edges indicate that more information is available by zooming in or acquiring at faster sampling rates In most cases zooming in will reveal the pulse that was not viewable with the previous settings If the white edge is still present after zooming in as far as possible this indicates that increasing the sample rate on the next acquisition will reveal
4. In addition the supply s power levels output purity and harmonic feedback into the power line must be characterized to comply with national and regional power quality standards Historically making these and many other power measurements on an oscilloscope has been a long manual and tedious process The MSO DP 03000 Series optional power analysis tools greatly simplify these tasks enabling quick and accurate analysis of power quality switching loss harmonics safe operating area SOA modulation ripple and slew rate di dt dv dt Completely integrated into the oscilloscope the power analysis tools provide automated repeatable power measurements with a touch of a button no external PC or complex Software setup is required 8 www tektronix com 10 0MS s 525i 1000 points NTSC Viewing an NTSC video signal Notice the intensity graded view provided by the DPO s ability to represent time amplitude and distribution of amplitude over time Video Design and Development Many video engineers have remained loyal to analog oscilloscopes believing the intensity gradations on an analog display are the only way to see certain video waveform details The MSO DP03000 Series fast waveform capture rate coupled with its intensity graded view of the signal provides the same information rich display as an analog oscilloscope but with much more detail and all the benefts of digital scopes Standard features such as IRE and mV
5. Operating Nonoperating Regulatory Electromagnetic Compatibility Safety mm in 203 2 8 416 6 16 4 147 3 5 8 kg Ib 4 17 9 2 8 62 19 5U 2 in 51 mm required on left side and rear of instrument Description 0 2C to 50 C 40 2C to 71 2C High 30 2C to 50 2C 5 to 45 Relative Humidity Low 0 C to 30 C 5 to 95 Relative Humidity High 30 C to 50 C 5 to 45 Relative Humidity Low 0 2C to 30 2C 5 to 95 Relative Humidity 3 000 meters 9 843 feet 12 000 meters 39 370 feet 0 31 Gams from 5 to 500 Hz 10 minutes each axis 3 axes 30 minutes total 2 46 Gams from 5 to 500 Hz 10 minutes each axis 3 axes 30 minutes total EC Council Directive 2004 108 EC UL61010 1 2004 CAN CSA C22 2 No 61010 1 04 EN61010 1 2001 IEC61010 1 2001 Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 FAX 781 665 0780 TestEquipmentDepot com Ordering Information Digital Phosphor Oscilloscopes MS03000 Series DPO 3000 Series DPO3000 Models Application Modules Product Description Modules Description DP03012 100 MHz 2 5 GS s 5M record length DPO3AUDIO Audio Serial Triggering and Analysis Module 2 channel digital phosphor oscilloscope Enables triggering on packet level information DPO3014 100 MHz 2 5 GS s 5M record length te eae 4 channel digital phosphor oscilloscope custom audio buses as well as analytical tools such as digital views of the signal bus views DP
6. Trigger on violations of both setup time and hold time between clock and data present on any of the input channels Trigger on pulse edge rates that are faster or slower than specifed Slope may be positive negative or either Trigger on all lines odd even or all felds on NTSC PAL and SECAM video signals Trigger on 480p 60 576p 50 720p 30 720p 50 720p 60 8751 60 1080i 50 1080i 60 1080p 24 1080p 24sF 1080p 25 1080p 30 1080p 50 1080p 60 and custom bi level and tri level sync video standards Trigger on Start Repeated Start Stop Missing ACK Address 7 or 10 bit Data or Address and Data on 12C buses up to 10 Mb s Trigger on SS MOSI MISO or MOSI and MISO on SPI buses up to 10 0 Mb s Trigger on Start of Frame Frame Type data remote error overload Identifer standard or extended Data Identifer and Data End of Frame Missing ACK or Bit Stuffing Error on CAN signals up to 1 Mb s Data can be further specifed to trigger on lt lt gt 2 or a Specift data value User adjustable sample point is set to 50 by default Trigger on Word Select Frame Sync or Data Data can be further specifed to trigger on lt lt gt 2 a specift data value or inside or outside of a range Maximum data rate for 12S LJ R is 12 5 Mb s Maximum data rate for TDM is 25 Mb s Trigger on Tx Start Bit Rx Start Bit Tx End of Packet Rx End of Packet Tx Data Rx Data Tx Parity Error and Rx Parity Error up to 10 Mb
7. complies with IEEE Standard 488 1 1987 RS 232 C and with Tektronix Standard Codes and Formats Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 16 www tektronix com FAX 781 665 0780 TestEquipmentDepot com
8. determining how long the previous waveform acquisitions stay on screen This allows you to determine how often an anomaly is occurring Mixed Signal Design and Analysis MSO Series The MS03000 Series Mixed Signal Oscilloscopes provide 16 digital channels These channels are tightly integrated into the oscilloscope s user interface simplifying operation and making it possible to solve mixed signal issues easily Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 Leo es Ld eS se ee e n y p E a SS ee S 100kS s I 10k points EETALLLA D15 D0 f Timing Resolution 10 0us The MSO Series provides 16 integrated digital channels enabling you to view and analyze time correlated analog and digital signals Tek EE eee ees ee ee Digital Channel PD 7 Vertical Position 1 08 0 0 1 40 V GS 03 UU UU UU UU UU UT ll 2 50 V iA i 5 O CMOS 3 3V CMOS 2 5V CMOS ECL Choose Preset 1 4V Apply Preset to D 0 Apply Preset to GiS 08 D15 D0 Edit Magniy u On Off Theeshots Labels on Off With the color coded digital waveform display groups are created by simply placing digital channels together on the screen allowing the digital channels to be moved as a group You can set threshold values for each pod of eight channels enabling support for up to two different logic families Height Ss M L Color coded Digital Waveform Display
9. higher frequency information than the previous settings could acquire The MS03000 Series simplifes channel setup by allowing you to group digital waveforms and enter waveform labels by using a USB keyboard By simply placing digital waveforms next to each other they form a group The P6316 MSO probe offers two eight channel pods to simplify connecting to your device Once a group is formed you can position all the channels contained in that group collectively This greatly reduces the normal setup time associated with positioning channels individually MagniVu High speed Acquisition The main digital acquisition mode on the MS03000 Series will capture up to 5 Mpoints at 500 MS s 2 ns resolution In addition to the main record the MS03000 provides an ultra high resolution record called MagniVu which acquires 10 000 points atup to 8 25 GS s 121 2 ps resolution Both main and MagniVu waveforms are acquired on every trigger and can be switched between in the display at any time running or stopped MagniVu provides signiftantly fner timing resolution than comparable MSOs on the market instilling confidence when making critical timing measurements on digital waveforms P6316 MSO Probe This unique probe design offers two eight channel pods simplifying the process of connecting to the device under test When connecting to square pins the P6316 can connect directly to 8x2 square pin headers spaced on tenth inch centers When mo
10. your PC Key Software applications NI LabVIEW SignalExpress Tektronix Edition LE OpenChoice Desktop and Microsoft Excel and Word toolbars are included standard with each oscilloscope to enable fast and easy direct communication with your Windows PC Preferences Screen mma Waveform Get amp Send Capture fiat Data Caplure Settings Select Instrument 10 078 Ons Ss ee a T k pectin Bisa Timing Resolution 10 Opry Copy to Clipboard MS03054 DAC Capture Modify Note Tektronix Pa Mi OpenChoice Desktop software enables seamless connection between the oscilloscope and your PC NI LabVIEW SignalExpress Tektronix Edition LE enables you to instantly acquire generate analyze compare import and save measurement data and signals using an intuitive drag and drop user interface that does not require any programming The optional Professional Version offers over 200 built in functions that provide additional signal processing advanced analysis sweeping limit testing and user defned step capabilities For simple tasks the included OpenChoice Desktop enables fast and easy communication between the oscilloscope and your PC through USB or LAN for transferring settings waveforms and screen images Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 10 www tektronix com FAX 781 665 0780 TestEquipmentDepot com Digital Phosphor Oscilloscopes MS03000 Series DPO 3000 Series
11. 00 mV 3 of threshold setting Maximum Input Dynamic 50 Vox p threshold setting dependent Range Minimum Voltage Swing 500 MV pk pk Input Impedance 101 kO Probe Loading 8 pF Vertical Resolution 1 bit Horizontal System Analog Channels All MSO3000 Models All DPO3000 Models 2 5 GS s Characteristic Maximum Sample Rate all channels Maximum Record Length 5 Mpoints all channels Maximum Duration of 2 ms Time Captured at Highest Sample Rate all channels Time base Range s div 1 ns to 1000s Time base Delay Time 10 divisions to 5000 s Range Channel to Channel 100 ns Deskew Range Time base Accuracy 10 ppm over any 21 ms interval Horizontal System Digital Channels All MSO3000 Models 500 MS s 2 ns resolution Characteristic Maximum Sample Rate Main all channels Maximum Record Length 5 Mpoints Main all channels Maximum Sample Rate 8 25 GS s 121 2 ps resolution MagniVu all channels Maximum Record Length 10 kpoints centered on the trigger MagniVu all channels Minimum Detectable 2 0 ns Pulse Width Channel to Channel 500 ps typical Skew Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 FAX 781 665 0780 TestEquipmentDepot com www tektronix com 11 Data Sheet Trigger System Characteristic Main Trigger Modes Trigger Coupling Trigger Holdoff Range Trigger Modes Mode Edge Sequence B trigger Pulse Width Runt Logic Setup and Hold R
12. 03032 300 MHz 2 5 GS s 5M record length packet decoding search tools and packet decode 2 channel digital phosphor oscilloscope tables with time stamp information DP 03034 300 MHz 2 5 GS s 5M record length DPO3AUTO Automotive Serial Triggering and Analysis Module 4 channel digital phosphor oscilloscope Enables triggering on packet level information on CAN bus and LIN bus as well as analytical tools DARN ee eia a cin such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information MS0O3000 Models DPO3COMP Computer Serial Triggering and Analysis Module product D oti Enables triggering on packet level information on hitched chia eal RS 232 422 485 UART buses as well as analytical MS03012 100 MHz 2 5 GS s 5M record length tools such as digital views of the signal bus views 2 16 channel mixed signal oscilloscope packet decoding search tools and packet decode MS03014 100 MHz 2 5 GS s 5M record length eo 4 16 channel mixed signal oscilloscope DPO3EMBD ee Serial aoe fl ies nables triggering on packet level information on MS03032 300 MHz 2 5 GS s 5M record length 2c and SPI buses as well as analytical tools such 2 16 channel mixed signal oscilloscope as digital views of the signal bus views packet MS03034 300 MHz 2 5 GS s 5M record length decoding search tools and packet decode tables 4416 channel mixed signal oscilloscope with time stamp information Only two wire S
13. PI Support available on DPO 3012 DPO3032 models MS03054 500 MHz 2 5 GS s 5M record length accurate analysis of power quality switching loss harmonics safe operating area SOA modulation ripple and slew rate dl dt dV dt All Models Include One P6139A 500 MHz 10x Passive Probe per Analog Channel Front Cover 200 5052 xx User Manual Documentation CD 063 4104 xx DPO3VID HDTV and Custom nonstandard Video Triggering OpenChoice Desktop Software NI LabVIEW SignalExpress Tektronix Edition LE Module Software Calibration Certifirate Documenting Traceability to National Metrology Institute s and IS09001 Quality System Registration Power Cord Accessory Pouch 016 2008 xx Three year Warranty Please specify power plug and manual language version when ordering MSO Models also Include One P6316 16 channel logic probe and accessory kit Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 FAX 781 665 0780 TestEquipmentDepot com www tektronix com 15 Data Sheet Instrument Options Power Plug Options Option Description Opt A0 North America Opt Al Universal Euro Opt A2 United Kingdom Opt A3 Australia Opt A5 Switzerland Opt A6 J apan Opt A10 China Opt A11 India Opt A99 No power cord Language Options 2 Option Description Opt LO English manual Opt L1 French manual Opt L2 Italian manual Opt L3 German manual Opt L4 Spanish manual Opt L5 apanese manua
14. Test Equipment 1 800 517 8431 Digital Phosphor Oscilloscopes MSO3000 Series DPO3000 Series Data Sheet Features amp Benefits Key Performance Specifications 500 300 100 MHz Bandwidth Models 2 and 4 Analog Channel Models 16 Digital Channels MSO Series 2 5 GS s Sample Rate on All Channels 5 Megapoint Record Length on All Channels gt 50 000 wim s Maximum Waveform Capture Rate Suite of Advanced Triggers Ease of Use Features Wave Inspector Controls Provide Easy Navigation and Automated Search of Waveform Data 29 Automated Measurements and FFT Analysis for Simplifed Waveform Analysis TekVP1 Probe Interface Supports Active Differential and Current Probes for Automatic Scaling and Units 9 in 229 mm WVGA Widescreen Color Display Small Footprint and Lightweight Only 5 8 in 147 mm deep and 9 lb 4 kg Connectivity USB 2 0 Host Porton both the Front Panel and Rear Panel for Quick and Easy Data Storage Printing and Connecting a USB Keyboard USB 2 0 Device Port on Rear Panel for Easy Connection to a PC or Direct Printing to a PictBridge compatible Printer Integrated 10 100 Ethernet Port for Network Connection and Video Out Port to Export the Oscilloscope Display to a Monitor or Projector Optional Serial Triggering and Analysis Automated Serial Triggering Decode and Search Options for 12C SPI CAN LIN RS 232 422 485 UART and 2S L RJ TDM Mixed Signal Design and Anal
15. al pixels WVGA Vectors Dots Variable Persistence Infnite Persistence Full Grid Cross Hair Frame IRE and mV YT and XY gt 50 000 wfm s Description Supports USB mass storage devices printers and keyboards One port available on rear panel and one on front panel Rear panel connector allows for communication control of oscilloscope through USBTMC or GPIB with a TEK USB 488 and direct printing to all P ictBridge compatible printers RJ 45 connector supports 10 100Base T DB 15 female connector connect to show the oscilloscope display on an external monitor or projector Front panel BNC connector Input Impedance 1MQ Max input 300 Vans CAT II with peaks lt 450 V Front panel pins Amplitude 2 5 V Frequency 1 kHz Rear panel BNC connector provides a negative polarity pulse when the oscilloscope triggers Rear panel security slot connects to standard Kensington style lock Description 85 to 265 V 10 45 to 440 Hz 85 to 265 V 120 W maximum Output Voltage 12 V Output Current 5 A Power Consumption 50 W 1 Required when total oscilloscope probe power usage exceeds 20 W 14 www tektronix com Physical Characteristics Dimensions Height Width Depth Weight Net Shipping Rackmount Confguration Cooling Clearance Environmental Characteristic Temperature Operating Nonoperating Humidity Operating Nonoperating Altitude Operating Nonoperating Random Vibration
16. ay want to reference later for further investigation Or automatically search your record for criteria you defne Wave Inspector will instantly search your entire record including analog digital and serial bus data Along the way it will automatically mark every occurrence of your defned event so you can quickly move between events Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 FE 2 50GS s F JL 100k points 1 72 V Analyze FFT analysis of a pulsed signal A comprehensive set of integrated analysis tools speeds verifration of your design s performance Analyze Verifying that your prototype s performance matches simulations and meets the project s design goals requires analyzing its behavior Tasks can range from simple checks of rise times and pulse widths to sophisticated power loss analysis and investigation of noise sources The MSO DP03000 Series offers a comprehensive set of integrated analysis tools including waveform and screen based cursors 29 automated measurements advanced waveform math including arbitrary equation editing FFT analysis and trend plots for visually determining how a measurement is changing over time Specialized application Support for serial bus analysis power supply design and video design and development is also available For extended analysis National Instrument s LabVIEW SignalE xpress Tektronix Edition provides over 200 built in functions inclu
17. bility of capturing elusive glitches and other infrequent events Comprehensive Features Speed Every Stage of Debug The MSO DP03000 Series offers a robust set of features to speed every Stage of debugging your design from quickly discovering an anomaly and Capturing it to searching your waveform record for the event and analyzing its characteristics and your device s behavior Discover To debug a design problem frst you must know it exists Every design engineer spends time looking for problems in their design a time consuming and frustrating task without the right debug tools The MSO DP 03000 Series offers the industry s most complete visualization of signals providing fast insight into the real operation of your device A fast waveform capture rate greater than 50 000 waveforms per second enables you to see glitches and other infrequent transients within seconds revealing the true nature of device faults A digital phosphor display with intensity grading shows the history of a signal s activity by intensifying areas of the signal that occur more frequently providing a visual display of just how often anomalies occur 2 www tektronix com PreVu Trigger On coe ee ooms 25 0MS S nx bata Uev9 17320ms IM points BTS B Olea a ots ct eee DO J Timing Resolution 40 0ns Resolution 40 0ns Capture Triggering on a specift transmit data packet going across an RS 232 bus A complete set of triggers inc
18. defned events All occurrences of the event are highlighted with search marks and are easily navigated to using the front panel Previous lt and Next buttons Search types include edge pulse width glitch runt logic setup and hold rise fall time parallel bus and I2C SPI CAN LIN RS 232 422 485 UART and I2S L RJ TDM packet content Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 FAX 781 665 0780 TestEquipmentDepot com Digital Phosphor Oscilloscopes MS03000 Series DPO3000 Series Tek EF ESPPR tH tex 2 Meelis 4 2 50GS s fn 3 BS 1000 points Digital phosphor technology enables greater than 50 000 wfm s waveform capture rate and real time intensity grading on the MSO DP 03000 Series Digital Phosphor Technology The MSO DP 03000 Series digital phosphor technology provides you with fast insight into the real operation of your device Its fast waveform capture rate greater than 50 000 wfm s gives you a high probability of quickly seeing the infrequent problems common in digital systems runt pulses glitches timing issues and more Waveforms are superimposed with one another and waveform points that occur more frequently are intensifed This quickly highlights the events that over time occur more often or in the case of infrequent anomalies occur less often With the MSO DP03000 Series you can choose infnite persistence or variable persistence
19. ding time and frequency domain analysis limit testing data logging and customizable reports www tektronix com 3 FAX 781 665 0780 TestEquipmentDepot com Data Sheet Wave Inspector controls provide unprecedented efftiency in viewing navigating and analyzing waveform data Zip through your 5 Mpoint record by turning the outer pan control 1 Get from the beginning to end in seconds See something of interest and want to see more details J ust turn the inner zoom control 2 Wave Inspector Navigation and Search A 5 Mpoint record length represents thousands of screens of information The MSO DP 03000 Series enables you to fnd your event in seconds with Wave Inspector the industry s best tool for navigation and search Wave Inspector offers the following innovative controls Zoom Pan A dedicated two tier front panel control provides intuitive control of both zooming and panning The inner control adjusts the zoom factor or zoom scale turning it clockwise activates zoom and goes to progressively higher zoom factors while turning it counterclockwise results in lower zoom factors and eventually turning zoom off No longer do you need to navigate through multiple menus to adjust your zoom view The outer control pans the zoom box across the waveform to quickly get to the portion of waveform you are interested in The outer control also utilizes force feedback to determine how fast to pan on the waveform The farther you t
20. ed consecutively with columns for each component Address Data etc Search Serial triggering is very useful for isolating the event of interest but once you ve captured it and need to analyze the surrounding data what do you do In the past users had to manually scroll through the waveform counting and converting bits and looking for what caused the event With the MSO DP03000 Series you can have the oscilloscope automatically search through the acquired data for user defned criteria including serial packet content Each occurrence is highlighted by a search mark Rapid navigation between marks Is as simple as pressing the Previous lt and Next buttons on the front panel Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 FAX 781 665 0780 TestEquipmentDepot com www tektronix com 7 Data Sheet A 12 0ms 12 0ms 24 0ms 32 3 V 700mv 316 V 24 0mA 128mA 104mA xxy i 775mW 89 6mW 3 29W SOA Mask Test Passed Waveforms Acquired 382 Failing Samples 0 coms 2 50MS s f J i 100k points 4 60 V Application Power Safe operating area measurement Automated power measurements enable quick and accurate analysis of common power parameters Power Analysis Optional Ever increasing consumer demand for longer battery life devices and for green solutions that consume less power require power supply designers to characterize and minimize switching losses to improve efftiency
21. graticules holdoff by felds video polarity and an Autoset smart enough to detect video signals make the MSO DP03000 Series the easiest to use oscilloscope on the market for video applications And with up to a 500 MHz bandwidth four analog inputs and a built in 75 Q input termination the MSO DP0 3000 Series provides ample performance for analog and digital video use The MSO DP03000 Series video functionality is further extended with the optional DPO3VID video application module DPO3VID provides the industry s most complete suite of HDTV and custom nonstandard video triggers Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 FAX 781 665 0780 TestEquipmentDepot com Digital Phosphor Oscilloscopes MS03000 Series DPO3000 Series e _JCJICJICICJICJICje gl The MSO DP 03000 is designed to make your work easier The large high resolution display shows intricate signal details Dedicated front panel controls simplify operation A USB host port on the front panel allows you to easily transfer screenshots instrument settings and waveform data to a memory stick Designed to Make Your Work Easier Large High resolution Display The MSO DP03000 Series features a 9 inch 229 mm widescreen high resolution 800 x 480 WVGA display for seeing intricate signal details Dedicated Front panel Controls Per channel vertical controls provide simple and intuitive operation No longer do you need to sha
22. ise Fall Time Video Extended Video optional I2C optional SPI optional CAN optional I2S L RJ TDM optional RS 232 422 485 UART optional LIN optional Parallel available on MSO models only Trigger Sensitivity Description Characteristic Description Auto Normal and Single Internal DC Coupled 0 5 div from DC to 50 MHz increasing to 1 div at DC AC HF reject attenuates gt 50 kHz LF ee reject attenuates lt 50 kHz noise reject reduces External 200 mV from DC to 50 MHz increasing to 500 mV sensitivity Auxiliary Input at 250 MHz 20 ns to 8s Trigger Level Range Characteristic Description Any Channel 8 divisions from center of screen External 8 V Auxiliary Input Description Positive or negative slope on any channel or front panel auxiliary input Coupling includes DC AC HF reject LF reject and noise reject Trigger Delay by Time 8 ns to 8s Or Trigger Delay by Events 1 to 9 999 999 events Trigger on width of positive or negative pulses that are gt lt or a Specifed period of time Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the frst again Trigger when any logical pattern of channels goes false or stays true for specified period of time Any input can be used as a clock to look for the pattern on a clock edge Pattern AND OR NAND NOR specifed for all analog and digital input channels defned as High Low or Don t Care
23. k Amplitude High Low Max Min Mean Cycle Mean RMS Cycle RMS Positive Pulse Count Negative Pulse Count Rising Edge Count Falling Edge Count Area and Cycle Area Mean Min Max Standard Deviation User defnable reference levels for automatic measurements can be specifed in either percent or units Isolate the specif occurrence within an acquisition to take measurements on using either the screen or waveform cursors Power Measurements Optional Measurement Power Quality Measurements Switching Loss Measurements Harmonics Ripple Measurements Modulation Analysis Safe Operating Area dV dt and dl dt Measurements Description Vrms Vcrestfactor Frequency lems IcrestFactory True Power Apparent Power Reactive Power Power Factor Phase Angle Power Loss Ton To Conduction Total Energy Loss Ton Tor Conduction Total THD F THD R RMS measurements Graphical and table displays of harmonics Test to IEC 61000 3 2 Class A and MIL STD 1399 Viipple ANC lrippie Graphical display of P ulse Width Pulse Width Period Frequency Duty Cycle and Duty Cycle modulation types Graphical display and mask testing of switching device safe operating area measurements Cursor measurements of slew rate Waveform Math Characteristic Arithmetic Math Functions FFT Advanced Math Software Product NI LabVIEW SignalE xpress Tektronix E dition OpenChoice Desktop IVI D
24. l Opt L6 Portuguese manual Opt L7 Simplifed Chinese manual Opt L8 Traditional Chinese manual Opt L9 Korean manual Opt L10 Russian manual Opt L99 No manual 2 Language options include translated front panel overlay for the selected language s Service Options 3 Option Description Opt C3 Calibration Service 3 years Opt C5 Calibration Service 5 years Opt CA1 Provides a single calibration event or coverage for the designated calibration interval whichever comes frst Opt D1 Calibration Data Report Opt D3 Calibration Data Report 3 years with Opt C3 Opt D5 Calibration Data Report 5 years with Opt C5 Opt R5 Repair Service 5 years including warranty 3 Probes and accessories are not covered by the oscilloscope warranty and Service Offerings Refer to the datasheet of each probe and accessory model for its unique warranty and calibration terms Recommended Probes Probe Description TAP 1500 1 5 GHz TekVP1 active voltage probe TAP 1500X2 Bundle of Two 1 5 GHz Active Probes single ended with TekVP Interface TDP0500 500 MHz TekVPI differential voltage probe with 42 V differential input voltage TDP1000 1 GHz TekVPI differential voltage probe with 42 V differential input voltage TCP0030 120 MHz TekVP I 30 Ampere AC DC current probe TCP0150 20 MHz TekVP 150 Ampere AC DC current probe TCPA300 400 4 Current measurement systems amplif r P5200 1 3 kV 25 MHz high voltage differential pr
25. lay Provides a higher level combined view of the individual signals clock data chip enable etc that make up your bus making it easy to identify where packets begin and end and identifying subpacket components such as address data identifer CRC etc Bus Decoding Tired of having to visually inspect the waveform to count clocks determine if each bit is a 1 ora 0 combine bits into bytes and determine the hex value Let the oscilloscope do it for you Once you ve set up a bus the Stop DLC Data Event Table 4269 6C6C 3 AE4F FFF1 0272 DF6B 11 1122 33 Time Identifier 519 1597EEB2 527DE32 140014 CRC Missing Ack woo 7a 1122 3344 55 F1F2 F3F4 F5F6 F7 0000 0000 0000 0000 Remote Frame 160016 18181818 oon vl 57 4568 6C65 7273 DESS CBFA 5045 ADSC 1122 1122 3344 1122 3344 5566 l C1C2 C3C4 B7B6 B4B4 1FFFFFFF FFFF FFFF FFFF FFFF selects an event 500000 Event table showing decoded Identifer DLC DATA and CRC for every CAN packet in a long acquisition MSO DP 03000 Series will decode each packet on the bus and display the value in hex binary decimal LIN only signed decimal I2S LJ RJ TDM only or ASCII RS 232 422 485 UART only in the bus waveform Event Table In addition to seeing decoded packet data on the bus waveform itself you can view all captured packets in a tabular view much like you would see in a software listing Packets are time stamped and list
26. luding triggers for specift serial packet content ensures you quickly capture your event of interest Bus p Rs 232 Trigger On 54h Capture Discovering a device fault is only the frst step Next you must capture the event of interest to identify root cause The MSO DP03000 Series provides a complete set of triggers including runt logic pulse width glitch setup hold violation serial packet and parallel data to help quickly fhd your event With up to a 5 Mpoint record length you can capture many events of interest even thousands of serial packets in a Single acquisition for further analysis while maintaining high resolution to zoom in on fhe signal details From triggering on specift packet content to automatic decode in multiple data formats the MSO DP03000 Series provides integrated support for the industry s broadest range of serial buses 12C SPI CAN LIN RS 232 422 485 UART and 12S LJ R TDM The ability to decode up to two serial and or parallel buses simultaneously means you gain insight into system level problems quickly To further help troubleshoot system level interactions in complex embedded systems the MS03000 Series offers 16 digital channels in addition to its analog channels Since the digital channels are fully integrated into the oscilloscope you can trigger across all input channels automatically time correlating all analog digital and serial signals The MagniVu high speed acquisitio
27. n enables you to acquire fhe signal detail up to 121 2 ps resolution around the trigger point for precision measurements MagniVu is essential for making accurate timing measurements for setup and hold measurements clock delay signal skew and glitch characterization Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 FAX 781 665 0780 TestEquipmentDepot com Digital Phosphor Oscilloscopes MS03000 Series DPO 3000 Series Prevyu M 10 0ms leed TEN EEE CLOCK IDATA Zoom Factor 250 X CLOCK 50 Bb 17 R 50 D 3 10 0MS s IM points V2 40 0us Bus Search events found 116 Search 12C decode showing results from a Wave Inspector search for Address value 50 Wave Inspector controls provide unprecedented efftiency in viewing and navigating waveform data Search Finding your event of interest in a long waveform record can be time consuming without the right search tools With today s record lengths pushing beyond a million data points locating your event can mean scrolling through thousands of screens of signal activity The MSO DP03000 Series offers the industry s most comprehensive search and waveform navigation with its innovative Wave Inspector controls These controls speed panning and zooming through your record With a unique force feedback system you can move from one end of your record to the other in just seconds User marks allow you to mark any location that you m
28. obe P5205 1 3 kV 100 MHz high voltage differential probe P5210 4 5 6 kV 50 MHz high voltage differential probe P5100 2 5 kV 100X high voltage passive probe ADA400A 4 100X 10X 1X 0 1X high gain differential amplif r NEX HD2HEADER Mictor connector breakout to 0 1 in header pins DPO3PWRBND Includes P5205 and TDP 0500 differential voltage Power Solution probes TCP0030 current probe TPA BNC Bundle adapter deskew pulse generator TEK DPG deskew fixture and power analysis module DPO3P WR ina hard sided carrying case Bundle discount refkcted in price 4 Requires TekVP1 to TekP robe BNC adapter TPA BNC Recommended Accessories Accessory Description 071 2667 xx Service Manual English only TPA BNC TekVP I to TekProbe BNC adapter TEK DPG TekVP I deskew pulse generator signal source 067 1686 xx Power Measurement Deskew and Calibration Fixture 119 7465 xx 5 TekVP1 External Power Supply SIGEXPTE NI LabVIEW SignalExpress Tektronix Edition Software Full Version FP GAView xx MSO Supportfor Altera and Xilinx FPGAs TEK USB 488 GPIB to USB adapter ACD4000 Soft Transit Case HCTEK 4321 Hard Transit Case requires ACD4000 RMD3000 Rackmount Kit 5 Required when total oscilloscope probe power usage exceeds 20 W Power cord not included Warranty Three year warranty covering all parts and labor excluding probes CE ag S0900 Product s are manufactured in ISO registered facilities Spe Product s
29. power supply TekVPI probes can be controlled remotely through USB GPIB or Ethernet enabling more versatile solutions in ATE environments Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 FAX 781 665 0780 TestEquipmentDepot com www tektronix com 9 Data Sheet fied DANA m fe tt e Tee ee ieee ee rp Qa Be thee ieee fie 2 be Base fo 1 _ a ma nami EJ ba ia ET Fire uaa et Loose name Gws J a pup mmm i 7 TS ii Here cht a Tek oo tH ie ofS birer F P po DR a dia a peo a Eae ae i sd Fsi m me Pi i i i t i LPE a ic ate I Emri e l ie rizi it baila iy Wl i iii T H an oy ELIS pE Wy Un Li i Hi li WENT ITT I i 1h n f A A e MERETI TAAN H im ro T 1 N fF T ae E ee ee ee es a n o i 4 b iib ayl Ln a Se one Dit a ni co Lee Faji J ten T ins ae oh iiai o aira z a patr T aia i a t m is am a m ee H h a imi E m th fer i NI LabVIEW SignalExpress Tektronix Edition is a fully interactive measurement acquisition and analysis software developed jointly with National Instruments and optimized for the MSO DPO Series Extended Analysis Acquiring data and measurements from the MSO DP0 3000 Series Is as simple as connecting a USB cable from the oscilloscope to
30. re attachment fexibility is required you can use the included fling lead sets and grabbers to clip onto surface mount devices or test points The P6316 offers outstanding electrical characteristics applying only 8 pF of capacitive loading with 101 kQ input impedance Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 FAX 781 665 0780 TestEquipmentDepot com 6 www tektronix com Digital Phosphor Oscilloscopes MS03000 Series DPO 3000 Series Addr R 50 Data 18 Data 1A Data LO DATA 20 0us 2 50GS S Addr J 1M points Data PETR gt Timing Resolution 2 00ns Triggering on a specift data packet going across an 12C bus The yellow waveform is clock and the blue waveform is data A bus waveform provides decoded packet content including Start Address Read Write Data and Stop Serial Triggering and Analysis Optional Ona Serial bus a Single signal often includes address control data and clock information This can make isolating events of interest diffcult The MSO DP0O3000 Series offers a robust set of tools for debugging serial buses with automatic trigger decode and search for 12C SPI CAN LIN RS 232 422 485 UART and 2S L R TDM Serial Triggering Trigger on packet content such as start of packet specif addresses specif data content unique identifers etc on popular serial interfaces such as 12C SPI CAN LIN RS 232 422 485 UART and 2S L RJ TDM Bus Disp
31. re one set of vertical controls across all four channels Connectivity A USB host port on the front panel enables easy transfer of screenshots instrument settings and waveform data to a memory stick The rear panel contains a second USB host port and a USB device port for controlling the oscilloscope remotely from a PC or for connecting a USB keyboard The USB device port can also be used to print directly to a PictBridge compatible printer An integrated 10 100 Ethernet port enables easy connection to networks and a Video Out port allows the oscilloscope display to be exported to an external monitor or projector Compact Form Factor A compact portable form factor allows the MSO DP 03000 Series to be easily moved between labs and with a depth of just 5 8 inches 147 mm it Saves you valuable space on your test bench 2 mo L The MSO DP 03000 Series compact form factor frees up valuable space on your bench or desktop oo TekVPI probe interface simplifes connecting your probes to the oscilloscope TekVPI Probe Interface The TekVP1 probe interface sets the standard for ease of use in probing TekVPI probes feature status indicators and controls as well as a probe menu button right on the comp box itself This button brings up a probe menu on the oscilloscope display with all relevant settings and controls for the probe The TekVPI interface enables direct attachment of current probes without requiring a Separate
32. river eScope Description Add subtract multiply and divide waveforms Integrate Differentiate FFT Spectral magnitude Set FFT Vertical Scale to Linear RMS or dBV RMS and FFT Window to Rectangular Hamming Hanning or Blackman Harris Define extensive algebraic expressions including waveforms reference waveforms math functions FFT Intg Diff Log Exp Sqrt Sine Cosine Tangent scalars up to two uSer adjustable variables and results of parametric measurements Period Freq Delay Rise Fall PosWidth NegWidth BurstWidth Phase PosDutyCycle NegDutyCycle PosOverS hoot NegOverS hoot PeakPeak Amplitude RMS CycleRMS High Low Max Min Mean CycleMean Area CycleArea and trend plots e g Intg Chl Mean Chl x 1 414 x VAR1 Description A fully interactive measurement software environment optimized for the MSO DP 03000 Series enables you to instantly acquire generate analyze compare import and save measurement data and signals using an intuitive drag and drop user interface that does not require any programming Standard MSO DP0 3000 Series support for acquiring controlling viewing and exporting your live signal data is permanently available through the software The full version SIGEXPTE adds additional signal processing advanced analysis mixed signal sweeping limit testing and user defined step capabilities and is available for a 30 day trial period standard with each instrument
33. s Trigger on Sync Identifer Data Identifer and Data Wakeup Frame Sleep Frame Errors such as Sync Parity or Checksum Errors up to 1 Mb s by LIN defnition 20 kb s Trigger on a parallel bus data value Parallel bus can be from 1 to 16 bits in size Binary and Hex radices are supported Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 12 www tektronix com FAX 781 665 0780 TestEquipmentDepot com Acquisition Modes Mode Sample Peak Detect Averaging Envelope Hi Res Roll Digital Phosphor Oscilloscopes MS03000 Series DPO3000 Series Description Acquire sampled values Captures glitches as narrow as 2 ns atall sweep speeds From 2 to 512 waveforms included in average Min max envelope refkcting Peak Detect data over multiple acquisitions Real time boxcar averaging reduces random noise and increases vertical resolution Scrolls waveforms right to left across the screen at Sweep speeds slower than or equal to 40 ms div Waveform Measurements Measurement Cursors Automatic Measurements Measurement Statistics Reference Levels Gating Description Waveform and Screen 29 of which up to four can be displayed on screen at any one time Measurements include Period Frequency Delay Rise Time Fall Time Positive Duty Cycle Negative Duty Cycle Positive Pulse Width Negative Pulse Width Burst Width Phase Positive Overshoot Negative Overshoot P eak to Pea
34. urn the outer control the faster the zoom box moves Pan direction is changed by simply turning the control the other way Play Pause A dedicated Play Pause front panel button scrolls the waveform across the display automatically while you look for anomalies or an event of interest Playback speed and direction are controlled using the intuitive pan control Once again turning the control further makes the waveform scroll faster and changing direction is as simple as turning the control the other way 4 www tektronix com CAN Data Zoom Factor 500X selects a binary or hex digit sets its value Id 1597 EEA3 84D DEHD 55D CB 2 20 0us 10 0MS s J 1M points Bus Search events found 33 On Bus ED CAN Id amp Data Search step 1 You define what you would like to find Zoom Factor 500 X 2 4D 11 D 22 CRC 61A8 10 0MS s Fa Bus Searcheventsfound D CORT a Z 20 0yus Search step 2 Wave Inspector automatically searches through the record and marks each event with a hollow white triangle You can then use the Previous and Next buttons to jump from one event to the next User Marks Press the Set Mark front panel button to place one or more marks on the waveform Navigating between marks is as simple as pressing the Previous lt and Next buttons on the front panel Search Marks The Search button allows you to automatically search through your long acquisition looking for user
35. ysis MSO Series Automated Triggering Decode and Search on Parallel Buses Multichannel Setup and Hold Triggering MagniVu High speed Acquisition Provides 121 2 ps Fine Timing Resolution on Digital Channels Optional Application Support Power Analysis HDTV and Custom Video Analysis Feature rich Tools for Debugging Mixed Signal Designs With the MSO DP03000 Oscilloscope Series you can visualize analog digital and serial signals with a single instrument to quickly fnd and diagnose problems in complex embedded system designs Bandwidths up to 500 MHz and a minimum of 5x oversampling on all channels provides the performance needed for many of today s mainstream applications A deep record length of up to 5 Mpoints is standard on all channels enabling you to capture long windows of signal activity while maintaining fhe timing resolution With Digital Phosphor technology for fast visualization of signal anomalies Wave Inspector controls for rapid waveform navigation and automated serial bus and power analysis the MSO DP03000 Oscilloscope Series from Tektronix provides the feature rich tools you need to simplify and speed debug of your complex design Tektronix Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 FAX 781 665 0780 TestEquipmentDepot com Data Sheet 2 50GS S F l 1000 points 1 30 V Discover Fast waveform capture rate over 50 000 wfm s maximizes the proba