Home
2 TONE - Vupiesse Italia
Contents
1. Face amp Body CONTENTS OF PACKAGING 1 electrostimulator with 2 outputs part no SLTTBF 1 face treatment wand part no SLTTFMA 1 kit of 4 adhesive electrodes 35x45 part no ELAD3545 1 kit of 4 adhesive electrodes 40x90 part no ELAD4090 2 leads for electrodes part no VATWO6 1 kit of 6 spare sponges for face electrodes VATRO9 1 mains adaptor part no VATR11 1 water sprayer part no VAVI19 1 short form operation manual part no VATRO8 1 DVD manual part no VATR10 PRODUCT DESCRIPTION TUA TRE ND Face amp Body is a complete electrostimulation appliance for treating every part of the body The control unit does in fact generate different wave shapes for the body and face A symmetric biphasic rectangular current is used for all body treatments and a perfectly sinusoidal current suitably modulated is used for the smaller and delicate muscles of the face The work programs are completely pre programmed and already complete with all specific parameters such as stimulation frequency pulse width contraction times and recovery times only the stimulation intensity has to be regulated For body treatments the machine has 2 independent outputs for piloting 4 adhesive gel electrodes especially suited for all body area applications The intensity of stimulation can be regulated directly by the user by means of precise 1 mA steps For face treatments TUA TRE ND Face amp Body features a special patented ele
2. As and from today all the advantages of electrostimulation are at your disposal In human beings skeletal muscle contraction is controlled by the central nervous system by means of electro chemical impulses conveyed through the nervous system The electro muscle stimulator is an appliance able to generate specific electrical currents that cause muscle contraction by substituting the impulses generated by the central nervous system In this case the current is applied at the point where the nerve comes into contact with the muscle cells neuromuscular plate By modulating a series of variable parameters like the frequency of electrical impulses duration of contraction and recovery etc various programs can be obtained useful for achieving different goals strengthening muscle power toning up beauty treatment right up to the decontraction of injured and contracted muscles Besides the correct positioning of the electrodes see attached tables care must also be given to choosing the right program for the result to be achieved On this in fact will depend to a great extent the success of training through induced electric stimulation BENEFITS OF ELECTROSTIMULATION Training by electrostimulation provides a number of advantages which when used according to criteria suited to the specific context are such as to integrate and partially replace voluntary training Among these can be included Selective stimulation of the muscle group o
3. Be careful because this is a very delicate area to be treated with low intensity 55
4. APPLICATIONS positioning of electrodes 25 FACE TREATMENT Connect the face stimulation wand to the face output of TUA TRE ND Face amp Body CAUTION the left socket g MA da PERA ta TREND Switch on the appliance while keeping the central key O pressed for over 1 second The displav screen will light up and make it possible to select the part of the bodv to be treated bv means of the right arrow kev j or left arrow kev r m A Confirm the FACE function by means of the central ENTER button O 26 p 1 The display screen shows the selected program 01 the JOS number of phases the total treatment time expressed in IPROG co 9 minutes in this case 3 the battery charge condition the face ri H icon showing the area to be treated and the program phase indication TUA TRE ND Face amp Body face section features 5 treatment programs which can be selected by means of the right arrow key forward movement or left arrow key to move back each of which is specific for a face area The example shows the program 1 selection procedure specific for the cheek bone area At this point the selection procedure ends and treatment can start To start the program press the ENTER button The intensity of the stimulation current expressed in milliamperes is indicated on the display screen on the right This is initially set at OO By means of the up arrow button and down arrow button gt t
5. T gt a e CO 10 BACK OF THIGHS Firming and toning the back part of the thighs The muscles must work isometrically if contraction produces excessive limb movement it is best to keep these blocked to prevent muscle shortening and to make stimulation comfortable and safe 1SLIM THIGH BICEPS PARTIALLY GLUTEUS 2 TONE 3 LIPOCELL Prone position fr 2 channels 4 electrodes Always keep to the indicated polarity GREY AND BLACK 42 11 e CALVES Firming and toning of calves The muscles must work isometrically if contraction produces excessive limb movement it is best to keep these blocked to prevent muscle shortening and to make stimulation comfortable and safe 1SLIM CALVES 2 TONE Prone position SS 2 channels 4 electrodes Always keep to the indicated polarity GREY AND BLACK 43 A ae I f 3 2 Ze Z G 9 Ca Zz e I T A i Q OQ T gt a e aa 12 e TRAPEZIUS AREA De contraction of upper trapezius of cervical area and muscles alongside the top part of the spinal column The muscles must work isometrically if contraction produces excessive limb movement it is best to keep these blocked to prevent muscle shortening and to make stimulation comfortable and safe Programs Muscles involved 6 RELAX TRAPEZIUS 2 TONE Take up the position shown in the illustration Seated or prone i Position of the electrodes on the body as sho
6. TUA TREND Face amp Body offers an excellent means of dealing with this widespread problem Constant use possibly combined with a low calorie diet can give remarkable results 4 MASS Specific program for building up muscle mass and strength the hypertrophic action of this program helps restore volume and trophism to the area involved 5 M STRENGTH The M STRENGTH program is specific for strengthening muscles especially the para vertebral and latissimus dorsi Electrode positioning for all the muscles is mirrored with respect to that indicated for excito motor electrostimulation 6 RELAX This program is expressly conceived to decontract and relax the muscles i e cervical area upper trapezium and muscle alongside the spine Muscle contraction causes tensions in the connective fibres which on hardening prevent the intra dermal exchange required for normal function of the muscle masses TUA TREND BODY amp FACE s RELAX program acts on the contracted areas of the body and improves blood flow It also relaxes taut and stiff muscles and facilitates the quick neuro muscular re adaptation of the area WORK PHASES Most of the programs described consist of 3 work phases warm up training cool down At the end of each work phase TUA TRENND Face amp Body automatically switches to the next phase The duration of the programs is preset as is the duration of each single phase program Total
7. if contraction produces excessive limb movement it is best to keep these blocked to prevent muscle shortening and to make stimulation comfortable and safe 1 SLIM THIGH BICEPS 2 TONE 4 MASS DI Seated or supine position J 2 channels 4 electrodes Always keep to the indicated polarity GREY AND BLACK 39 a DE _ f O v Z Z e O N L e lt L A kem O_ 2E T pe a e aa Firming shaping lifting and slimming of buttocks The muscles must work isometrically if contraction produces excessive limb movement it is best to keep these blocked to prevent muscle shortening and to make stimulation comfortable and safe 1 SLIM LARGE GLUTEUS 2 TONE i jA Prone position OS Sue 2 channels 4 electrodes Always keep to the indicated polarity GREY AND BLACK 40 Firming and toning lifting and slimming of buttocks The muscles must work isometrically if contraction produces excessive limb movement it is best to keep these blocked to prevent muscle shortening and to make stimulation comfortable and safe The use of 4 electrodes on a single gluteus is recommended when treating very voluminous buttocks 1 SLIM LARGE GLUTEUS 2 TONE fa Prone position LAW 2 channels 4 electrodes Always keep to the indicated polarity GREY AND BLACK 41 a a ea I if a Z e S N Z e I T WA Q O
8. promptly used thus considerably speeding up recovery and strengthening processes MAIN CONTRAINDICATIONS AND WARNINGS During the menstrual cycle skin conductivity changes stimulation could prove less pleasant Stimulation can cause reddening of the skin where the electrodes are applied above all in the case of people with very sensitive skin Such reddening is perfectly normal and usually disappears fairly quickly Patients allergic to the gel of the electrodes should suspend treatment and see a doctor Do not apply the electrodes on hyperpigmented areas large moles and varicose veins Do not apply the electrodes directly on the breasts but rather on the muscles that support the breasts Do not use in intimate and delicate areas armpits groin knee cavities Do not use on the abdomen of pregnant women Do not use TUA TREND on children pace maker wearers and people in weak psycho physical condition or with physiological and organic ailments Do not use on people with metal prostheses silicone prostheses or aorta abdominal bypasses Do not use in transthoracic mode to prevent interference with the heart beat Do not use on people suffering from epilepsy or multiple sclerosis Do not apply near transplants Do not apply to persons suffering from tumour syndromes or major neurological illnesses Do not use on animals IN CASE OF DOUBT SEE A DOCTOR TUA TRE ND Well being in fashion TUA TRE ND
9. 5 cm or 9x4 cm minimum electrode surface 15 sq cm 29 RECHARGING THE BATTERIES Use the battery charger provided to recharge the battery set supplied with the appliance The batteries must be recharged when ample and deep muscle contractions are no longer achievable By means of the graphic display icon TUA TRE ND Face amp Body indicates the battery charge condition When the battery is completely down the appliance switches off and can only be switched on again after changing or recharging the batteries To recharge the batteries fit the battery charger plug in the socket and connect the battery charger to a power mains supply point The battery condition icon starts flashing on the display screen After charging the battery charger automatically disengages and the battery condition icon remains on the display screen If correctly used battery life expectations are around 300 charge discharge cycles For safety reasons during battery recharging appliance operation is deactivated If the appliance is not used for long periods of time remove the batteries from their housings REPLACING THE BATTERIES Remove the batteries from their housings and fit the new ones type AAA always alkaline respecting the polarities shown on the bottom of the housing If the machine is not used for long periods of time remove the batteries from their housing CLEANING THE APPLIANCE To clean the appliance only ever use a soft cloth if neces
10. ORIGINAL ITALIAN BEAUTY TOOLS CAUTION Before using the appliance read the instructions in this manual carefullv The manual contains important information on safetv operation maintenance and precise contraindications Look after the manual carefully for further reference This appliance must only be used for the purposes for which it was designed meaning for the electric stimulation of muscles for personal use beauty purposes as indicated and described in this manual only All other uses shall be deemed improper The manufacturer disclaims all liability for any damage or injury caused by improper wrong and unreasonable use The TUA world is the world of those GA who and in the midst c of others Everyday life y hardshi HPS anxieties and ig thek curio i osity thee energ ies an dt thevitaliti that anoune within US their v ver IO For this reason e entering the TUA orld is as easy fa practical as stayin e at home the appliances are used at home for just a few minutes a de fact that they are battery driven makes Ythem want to feel well wit h thems elv es hi b h y appeal ng A n he TUA world elei consists of a series of applia nces dedicated l i IV The absolutely portable Their carefully studied ergonomic and innovative _ ensures immediate use and makes ti li TUA Korldc contains MENT scientific l enc ce 4 a group Phat also leads the naglifaeture of profe
11. ctrode for perfect positioning on the various facial areas Svmbol indicating conformitv of the appliance with European Directives a e 2 4 8 6V battery powered direct current a A 3 Production lot number jj e lot number vear week of manufacture 4 Appliance with BF type fitted part a SA 5 Do not dispose of the device in the TREND common urban waste symmetrical biphasic rectangular current for stimulating body muscles sinusoidal current for stimulating face muscles ua rame e CE O Ta DESCRIPTION OF THE FACE WAND TUA TRE ND Face amp Body features a special patented electrode for perfect positioning on the various facial areas The total mobility of the 2 stainless steel electrodes covered with special cellulose domes permits adaptation to all facial areas as well as perfect contact on the bends and protrusions of different physical configurations DESCRIPTION OF PROGRAMS BO DY PROG RAMS TUA TRE ND Body section features 12 programs 6 for the upper body and 6 for the lower body 1 SLIM program for slimming fatty areas Localised adiposity caused by bad eating habits and a sedentary lifestyle is an increasingly more widespread problem universally acknowledged as producing considerable aesthetic damage but also as being bad for the health The way to reduce adipose is to regulate the energy balance and this is possible in just two ways reduction in energy intake i e food inc
12. e selection procedure is now over and work can start TUA TRE ND Face amp Body generates a square shaped biphasic wave on the two channels The intensity of the current of each channel is expressed in milliamperes and is indicated on the display initially at 00 Press the right arrow key or left arrow key to select the channel on which to set the current value the selected channel flashes and by means of the arrow up button and arrow down button gt set the desired value with single step pressures of 1 mA or by keeping the buttons pressed so forward movement is continuous and faster ng l _ a LA La F LILI JOJU JOIU gt Sine ap a a foY oo 20 con TAN In the example the value of the left channel is set at 20 milliampere After a few seconds the display stops flashing the current intensity level is automatically stored The set value can also be confirmed by pressing ENTER e or selecting the current intensitv of the other channel bv means of the side arrow Repeat the same operations for the second channel The progress movement of the treatment time is indicated by the flashing clock icon and that of the minutes svmbol 23 REGULATING THE INTENSITY The pulses are alternated with intervals intensity adjustment must only be made during pulses and not during the intervals to avoid undesired excessive stimulations The best results can be achieved with deep contracti
13. ermittent beep The duration of the programs is already set as is the time of each phase program Total time Phase 1 Phase 2 No min Treatment sec Active recoverv sec 1 Cheekbone 3 150 30 2 Cheek 3 160 20 3 Forehead 3 150 30 4 Chin neck 3 160 20 5 Eye bags 3 160 20 Structure of program No 3 Forehead Program No 3 Total time 3 mo Phase FI Phase time 150 sec Intermittente stimulation Contraction Recoverv Time frequency 2 sec Olaz 1 sec Onpa Ramp up time 0 5 see 0 53 0 Ramp down time I if USING TUA TRE ND Face amp Body GRAPHIC DISPLAY BODY TREATMENT Before starting the appliance position the electrodes on the muscle area selected for treatment as indicated in the BODY APPLICATIONS positioning of electrodes Now connect the leads to one or both outputs Selected program body function Work phase of program face function Active program flashing symbol Remaining treatment time in minutes Contraction Pause indication Battery charge status 8088 Program number or indication of current intensity in mA Left channel Selection of body upper or lower part Face treatment areas Current intensity in mA Right channel 20 21 To start TUA TREND Face amp Body simply keep the ce
14. he desired value can be set with single step pressures of 1 mA or by keeping the buttons pressed so forward movement is continuous and faster In the example the value is set at 20 milliamperes The progress of treatment time is indicated by the flashing of the clock icon and that of the minutes symbol The number to the left of the clock symbol represents the selected program work phase REGULATING THE INTENSITY Always remember that individual sensitivity to current can vary considerably and very much depends on the physiological condition of the person on perspiration on the adipose layer on the condition of the electrodes and on the level of battery charge It is a good idea to increase the impulse level until maximum muscle contraction is achieved with acceptable current intensity The best results can be achieved with deep contractions but without everreaching uncomfortable and troublesome current levels The pulses are alternated with intervals intensity adjustment must only be made during pulses and not during the intervals to avoid undesired excessive stimulations At the end of treatment switch off TUA TRE ND by keeping the enter button O pressed for about 2 seconds 27 USING THE FACE APPLICATOR TUA TRE ND uses a special face applicator consisting of 2 sprung electrodes adjustable in every direction to be able to adapt to every face conformation The stainless steel electrodes are covered by special cellul
15. just itself through the next phases This will make the workout more comfortable and effective For instance in Program N 1 if you set the current at 50 mA when the treatment moves to phase 2 the current automatically adjusts itself to 45 mA and in phase 3 to 50 mA In Program 3 phase 1 is made by contraction and recovery therefore if you set the contraction current at 30 mA during the recovery phase the current will move to 33 MA In any case while the program is running both the contraction and recovery currents can be changed and TUA TREND microprocessor is able of handling them separately and storing in memories new set values 24 POSITIONING AND CONNECTING THE BODY ELECTRODES Remove the protective film from the adhesive electrodes being careful to put these aside for reuse Position a pair of adhesive electrodes on each muscle group involved in the treatment Connect the electrodes to a lead and fit this in the socket of an appliance channel Generally speaking the electrodes must be positioned following the general instructions described in the part of the manual relating to the applications These points are subjective after a few tests it will nonetheless be easy to identify the positions that ensure best stimulation Respect the polarity of the leads Adjust the position of the electrodes only after having reduced the stimulation current of the relevant channel on the appliance ELECTRODE POSITIONING see tha BODY
16. lved 1 SLIM LOWER ABDOMINALS 2 TONE e Take up the position shown in the illustration Supine position GATE 4 Position of the electrodes on the bodv as shown in the photo 2 channels 4 electrodes Always keep to the indicated polarity GREY AND BLACK 33 a G DE I f O v Z Z e O N L e lt L A em O_ A T gt Q e aa Slimming and firming the transverse abdominals and sides this application concentrates mainly on the transverse abdominals and sides During treatment the muscle must not be contracted due to a bad position 3 LIPOCELL TRANSVERSE ABDOMINALS 1 SLIM 2 TONE SL A p v Supine position T H 2 channels 4 electrodes Always keep to the indicated polarity GREY AND BLACK aa Strengthening of the upper abdominal muscles this application together with the 2 previous ones completes the successful treatment of all the abdominal muscles During treatment the muscle must not be contracted due to a bad position 2 TONE UPPER ABDOMINALS fol Supine position GATT 2 channels 4 electrodes Always keep to the indicated polarity GREY AND BLACK 35 A aa I if b VU Z Z e 3 VN Z e I L 2 O_ an L gt a aa Breasts Toning supporting muscles to model harden and lift the breasts Pectorals Strengthening and defining pectorals The muscles must work isometrical
17. ly if contraction produces limb movement slightly move the electrodes until appropriate stimulation is achieved Do not apply the electrodes directly on the breasts but rather on the muscles that support the breasts PECTORALIS MAJOR 4 MASS aN 2 TONE ao Seated or supine position T 2 channels 4 electrodes Always keep to the indicated polarity GREY AND BLACK Slimming and toning the internal and external part of the thighs The muscles must work isometrically if contraction produces excessive limb movement it is best to keep these blocked to prevent muscle shortening and to make stimulation comfortable and safe 3 LIPOCELL ADDUCTORS 1 SLIM 2 TONE Jt Seated or supine position ose JIA 2 channels 4 electrodes Always keep to the indicated polarity GREY AND BLACK 36 3 A G a I if b VU Z Z e 3 VN Z e I L 2 O_ an L gt a e aa Slimming and toning up the outer thighs The muscles must work isometricallv if contraction produces excessive limb movement it is best to keep these blocked to prevent muscle shortening and to make stimulation comfortable and safe 3 LIPOCELL ABDUCTORS 1 SLIM 2 TONE MM A Seated or supine position ose JA 2 channels 4 electrodes Always keep to the indicated polarity GREY AND BLACK Slimming and toning of the front part of the thighs The muscles must work isometrically
18. ng the adhesive gel electrodeS page 33 Lilian page 33 TES SIT ICAI AE A A ease ound E A A E page 34 Conformity withregulatioriS seuiiiisiiriaiiiiciiieiaiiiiseoiiiiiiia page 34 4 Body applications Face applications iii page 35 Lower abdominals aida page 35 Transverse BOC OMNES ga seines tiksi etti page 36 LUDPEerandonimal seriali page 37 Breasts PECtOralS uriiniaiia ian page 38 IMPERIO iS sali page 39 TJ page 40 Fica page 41 LUO RARE RE EE OR RR RT T page 42 EU RR A page 43 Back or CLUS ae RR RR ORO ERE fe page 44 elia page 45 WERE RO te MnP SE NOPD RETED Tin errteTrnrrTeT nnPR page 46 DTS AN EER A REIT page 47 Ce E A page 48 Pelvis and TMG ira e udtatieriead serait vrneeumdenenaees page 49 tA page 50 Lhc page 51 in page 52 Cheek bone GI page 52 E aa E EAEN page 53 FONCARdR ara page 54 Chin Jaw area and NECK ariani page 55 Bags under the EVES eessessenenzenzznannennzanenenzonznzznzzsasasanamaeazzzzonansesnonnenne net page 57 ELECTROSTIMULATION Electrostimulation exploits a natural principle of our body The brain in fact stimulates muscles through electro chemical impulses conveyed to the fibres In the same way through its electrodes TUA TREND conveys special low voltage currents to the muscles and tissues These currents are controlled and absolutely safe able to cause the passive contraction of the muscle fibres and increase blood flow in the areas involved
19. ng treatment the applicator can be moved as far as the ear following the shape of the face for a complete exercise on the entire cheek area This exercise contracts and lifts the upper lip causing the cheek and the lower part of the nose wing to stretch The stimulation of this area tones the cheek and gives the face a relaxed expression as if slightly smiling increasing the volume of the lip and combating the appearance of vertical wrinkles typical of ageing A second treatment envisages the electrode being positioned obliquely at the corner of the mouth this can be moved as far as the ear for a complete stimulation of the lower part of the cheek bone skimming the cheek A slight stretching is obtained of the corner of the mouth and the contraction of the muscles of the entire area which will appear more toned and firm 50 51 a Q D ee I re J Z Z 2 CO U wa e lt L imil O T LLI z eles The applicator must be rested on the temporal region with the two electrodes located obliquely between the ascula of the ear and the edge of the eyebrow slightly above the latter During the exercise the applicator can slide on the remainder of the forehead in order to treat the whole area Mind the intensity of the stimulation The forehead muscles are in fact very thin and delicate Consequently lower the intensity slightly if necessary Stimulation of the forehead muscles helps
20. ntral button O pressed for over 1 second the displav will light up and a beep will indicate the appliance has switched on To optimise battery consumption the display lighting switches off after about 5 seconds If any key is pressed the display lights up By means of the right arrow or left arrow select the body or face treatment Confirm by pressing the central button La T The example shows the selection of bodv function IO PROG f This display page now appears TUA TRE ND Face amp Body body section features 12 different treatment programs 6 for the lower body and 6 for the upper body Using the arrow up key 22 or arrow down key gt first of all select the part of the body to be treated TOP chest arm shoulder back BOTTOM thighs legs buttocks fi ON Now select the desired program using the right arrow kev U to move forward or left arrow kev to move back a In the example the bottom part of the bodv has been selected e co ER jU The example Joan illustrates the program PROG 3 selection procedures j na bottom part confirm a gn with the central button ENTER p The display shows the number of the selected program 3 the Ioan selected part of the body bottom the total treatment time ETA expressed in minutes in this case 30 minutes and the batterv charge with indication of intensitv on the two outputs o qa AU ja a LI e Th
21. ons but without ever reaching uncomfortable and troublesome current levels The TUA TRE ND Face amp Body programs are automatic and pre compiled to ensure utmost ease of use the parameters such as frequencies treatment times phase times and contraction and interval times are already set Most of the TUA TRE ND Face amp Body programs consist of 3 work phases this means they start with a few minutes of low frequency warm up to prepare the muscles for treatment and continue with the actual work phase before terminating with the cool down phase Each phase consists of contraction periods alternated with relaxation or interval periods At the end of each work phase TUA TRE ND Face amp Body automatically passes on to the next phase This is indicated by an intermittent beep The duration of the programs is already set as is the duration of each phase The recovery or interval phase is shown on the screen by the lighting up of the arrow pointing downwards while the contraction phase is shown by the arrow pointing upwards Contraction phase Pause or recovery phase OET v ORT a The end of the execution e Erne Ea dna of the work program is cL 45 cL 45 indicated by a long beep At the end of the treatment switch off TUA TREND Face amp Body while keeping the ENTER button O pressed for about 2 seconds IMPORTANT THE CURRENT VALUE IS SET AT THE FIRST PHASE OF THE PROGRAM During the treatment this current value will automatically ad
22. ose sponges Before each treatment dampen the sponges well using normal tap water and the special spray Be very careful the sponges must be perfectly wet otherwise they insulate and do not conduct the pulses Do not wet the electrode under the tap Water could leak inside and remain there for a long time POSITIONING THE FACE APPLICATOR See section FACE APPLICATIONS positioning of electrodes 28 TECHNICAL DETAILS Parameters Body programs Face programs No of outputs 2 1 Wave shape Symmetrical biphasic rectangular Sinusoidal modulated No of programs 12 6 6 5 Pulse width from150 uSec to 200 uSec Frequency range from 1 Hz to 80 Hz Contraction time 1 12 sec 3 Recovery time 223560 3 Current intensity 60 mA 60 MA max peak on impulse load 1Kohm 1KOhm load Power supply 4 x batteries 1 2V 750mA rechargeable AAA type cod VABA07 or 4 alkaline batteries 1 5 V AAA type Weight 120 g including batteries Dimensions 90 x 60 x 18mm Operating conditions Temperature from 0 to 35 C Humidity from 20 to 65 RH Storage Temperature from 0 to 50 C Humiditv from 10 to 85 RH Battery charger mod AD075020 Vupiesse Italia reorder code VATR11 Input AC 230V 50 60Hz Output DC 7 5V 200mA 1 5VA If adhesive gel electrodes of different brands are used carefully follow these instructions electrode measurement body section only 3 5x4
23. phism and muscular tone and drains liquids which have built up in the tissues TONE exercises muscles with prolonged contractions followed by short relaxing pauses This ensures demanding muscular work comparable to a with gym workout with heavy weights bodybuilding and consequent intense vascularization which enables rapid recovery of muscular tone and mass 3 LIPOCELL The LIPOCELL program gets rid of waste substances that tend to intoxicate cells catabolites thereby favouring liquid retention by means of the trophic and capillarising action of the specifically used frequencies Finally the lipolytic action of this program is targeted on triggering energy mechanisms that use fatty acids as substrate for biochemical reactions thus favouring their elimination 12 The 3 LIPOCELL program is also effective for treating cellulite Cellulite is an unsightly defect based on defective primary microcirculation leading to alteration of the adipose tissue and connective fibres The various existing treatments to contrast cellulite aim at improving circulation heat producing or vaso tonifying cosmetic products reduction of adiposity lipolytic products like algae iodine caffeine cola reduction of oedema pressotherapy draining cosmetics improvement of skin tone excitomotory contraction By combining 3 LIPOCELL 1 SLIM reduction of localised fat and 2 TONE restoration of skin and muscular tone programs
24. r part of this By positioning the electrodes correctly on the different Voluntarv brain marrow muscle muscles a specific stimulation toggeHino can be achieved on the selected muscle Reducing activity of the adjacent muscles to a minimum This is unlike what happens in the case of voluntary contraction where the muscles always work according to specific muscle chains and synergies For example the selective stimulation of the quadriceps Triggering bv electrostimulation ELECTROSTIMULATOR muscle or one of its heads like the vastus medialis can be achieved Maximum recruitment of muscle fibres By setting suitable current intensities the maximum recruitment of muscle fibres can be obtained something hard to achieve through voluntary contraction Absence of load on joints Especially on the spine where problems in this area often represent a limitation to physical activity in both sedentary and sportspersons Absence of general body tiredness This makes it possible to concentrate a high number of specific intensity training stimulations within a short period of time A large volume of work is thus done that would otherwise be impossible within the same space of time during the performance of traditional muscle activity programs Rapid progress Whether sports training beauty treatment or rehabilitation after injuries progress is always fast In this latter case in fact with due parameters electrostimulation can be
25. rbids discarding the product as domestic waste The directive establishes fines for the unlawful discarding of such wastes L IV amm l d d N d jie The symbol shown below crossed waste basket on wheels and on the TUA TREND data plate indicates that the waste of electrical and electronic equipment must be collected separately 21 CLASSIFICATION TUA TREND is a BF type internally powered appliance Class Il when connected to the battery charger BF type applied part Degree of protection against the penetration of liquids IPXO Not suitable for use with anaesthetic mixtures inflammable with air oxygen or nitrous oxide CONFORMITY WITH REGULATIONS TUA TREND bears the CE mark TUA TRE ND has been designed and manufactured in conformity with the requirements of the company quality system certified according to UNI EN ISO 9001 2000 and UNI EN ISO 13485 2004 standards For product audit the EN60335 2 32 2003 electrical safety standard has been applied Conformity with electromagnetic compatibility has been determined by applying standards EN50366 2003 EN55014 1 EN55014 2 EN61000 3 2 EN61000 3 3 32 a ae l i 3 VA Z G U L e lt L A au aw T gt a CO 1 LOWER ABDOMINALS Toning slimming and shaping the tummy in this position most work is done on the lower abdominals and treatment is targeted on the lower tummy Programs Muscles invo
26. reased energy consumption obtainable by raising the metabolism muscle activity or temperature The excito motor action of the SLIM program with its fast exercise short contractions followed by equally short pauses for relaxation comparable to aerobic workouts submits the treated area to a dynamic muscular activity which results in a considerable increase in local blood circulation and a consequent rise in temperature This results in increased energy consumption without any strain This sort of gymnastics also has the advantage of being able to be done by everybody without any cardiocirculatory involvement acceleration of breathing or heartbeat rates 2 TONE program for toning up and firming Loss of skin and muscle tone is a natural occurrence because during the course of the years Our skin gradually tends to become less elastic and lose water This results in its being less taut and firm Because we also become more sedentary as we grow older our muscles lose volume and tone Along with these tendencies tied to ageing other occurrences must be taken into consideration like pregnancy the sudden putting on of weight and slimming cellulite and hormone climactic all factors capable of causing an alternation of stretching and relaxing harmful to the elasticity of the skin TUA TRE ND Face amp Body s 2 TONE program is able to provide really focussed body sculpting using the action of the excito motor current which optimises tro
27. reduce expression wrinkles and raises the eyebrows 52 ony 1 E P l This program has been developed to stimulate several areas the chin jaw and neck area 4 1 Chin area the applicator is positioned horizontally on the chin right underneath the lower lip This exercise make the lower lip puffy and often increases its volume It contrasts atrophy a A D ea I i J Z Z 2 CO U wa e lt L imil O T LLI z EEE 4 2 Jaw area the applicator must be positioned immediately below the jaw between the corner and the apex following the conformation During the exercise the electrodes can slide along the entire lower jaw for a complete exercise on the whole area This exercise contracts the chin and tones up the jaw area helps sculpt the face oval and reduces the stretching caused by the drop of the Bichat s fat pad 4 3 Neck area the applicator will be positioned vertically and during the exercise will slide in this position to extend the work to the entire area Be careful because these muscles are delicate To start use low stimulation intensities This application is dedicated to the eye area The applicator must be positioned underneath the lower eyelid The lower lid and bag are contracted without lowering This is a very useful exercise because it provides draining stimulation and the squeezing of the bags under the eyes
28. s keep to the indicated polarity GREY AND BLACK 47 A ea I if b 9 Z el e VN Z e I L A O_ as L gt a aa 16 BICEPS Firming and toning of biceps Programs Muscles involved 1 SLIM ARM BICEPS 2 TONE 3 MASS Take up the position shown in the illustration Seated position Position of the electrodes on the body as shown in the photo 2 channels 4 electrodes Always keep to the indicated polarity GREY AND BLACK 48 17 TRICEPS Firming and toning of triceps The muscles must work isometrically if contraction produces excessive limb movement it is best to keep these blocked to prevent muscle shortening and to make stimulation comfortable and safe Programs Muscles involved 1 SLIM ARM TRICEPS 2 TONE Take up the position shown in the illustration Seated position Position of the electrodes on the body as shown in the photo 2 channels 4 electrodes Always keep to the indicated polarity GREY AND BLACK 49 a Q D ee I i J A Z 2 CO A va e lt L J imil O T LLI z EEE PROG rit Lit Position the applicator vertically just above the corner of the mouth as shown in In this exercise the applicator must be positioned obliquely right at the corner of the photo during operation the applicator can be moved along the entire cheek the jaw bone and just skim the eyelid Duri
29. sary sprayed with a neutral detergent product Do not use alcohol thinners solvents or other chemical products 30 CLEANING AND REPLACING THE SPONGES face electrode For proper hygiene it is best to remove the sponges from the electrode holder at the end of every treatment and wring them out well so no water remains The sponges can also be washed using a neutral detergent TUA TRE ND Face amp Body outfit contains an extra sponge kit these should be used when the original sponges are very dirty or worn out CHANGING THE ADHESIVE GEL ELECTRODES body electrode The adhesive gel electrodes last for 10 15 applications after which when these are no longer able to stick to the parts of the body to be treated and are no longer able to produce good contractions they must be changed DISPOSAL TUA TRE ND is an electronic device and as such contains electronic components that could be harmful for the environment and for human health if disposed of in a way not in conformity with applicable legal provisions Discard TUA TRE ND the parts it contains and the accessories in compliance with local regulations on waste disposal In particular alwavs discard old batteries into special containers Directive No 2002 96 EC requires product owners to dispose of it bv delivering it to a local Waste Electrical and Electronic Equipment WEEE Collection centre or giving it back to the dealer on making a new purchase and in anv case fo
30. ssional autjentreatment re iby top raf king youd over it is with the ICE comes to us from the work of a wel l tested t team of researchers at with the guarantee provided by the most stringent international quality cog ols that we sav to vou too A welcome to the world of TUA Electrostimulation TUA TRE ND face amp body Description of programs Using TUA TRE ND face amp body lil page 6 Benefits of electrostimulation s ssssssisssssssrssrssrssrssrssrssrsrrsrrerrnrsnrsersnras page 6 Main contraindications and Warnings page 7 BM ARRE RI TTI page 10 Contents of packaging arri page 10 PIOOUCLAESCIRlioni pi lcd page 11 Description of the face WAN emessssnnnnenzzznnsznzznnzanzanannzannn page 12 Lila page 14 Body 4 Qofa ANIM L IR page 14 E RR ROTA page 14 a Sett ert MTs nent a ner cnerr eT or etinre ttc page 14 EE CAI mena eo E ne eee ewe ra page 14 Li cai page 15 gt Il lead page 15 licia page 15 Vici page 16 Face programs Lala page 18 MIE lla page 20 lin page 22 CON CNG Oey RO RE page 22 Body TAS L page 23 CEI REC EA EE page 28 Using the face A PPICALON ica page 30 EG cal QEA a A ANOA page 31 Recharging the Batteries sssssssssssssssssssesssesesesesesssssssssssseeessesesssssssee page 32 Replacing the batteries eememennnnnznnzznsssassnzmsnanzznnnnasennznenznznnnnanznzrznn page 32 Cleaning tne APPIA page 32 Cleaning and replacing the SPONGES i page 33 Changi
31. time Phase 1 Phase 2 Phase 3 No min Warm up min Training min Cool down min 1 Slim JA A 18 2 2 Tone 30 10 ie 5 3 Lipocell 30 15 10 5 4 Mass JA 5 14 3 5 M strength 26 5 16 5 6 Relax 30 30 e Example of 3 phase program 2 Tone lower body Total time 30 maini Phase F1 F2 F3 Phase time 10 mim 15 mio 5 jenn Cont stimulation Intermittent stimulation Cont stimulation Contraction Recovery Time frequency 8 Hz 8sec 502 Pee lia 2 i Ramp up time 1 5 sec sal Gee 0 Ramp down time 5sea 5 sec 0 Pulse width 180 usec 200 usec 200 usec FACE PROGRAMS The face section of TUA TRE ND Face amp Body consists of 5 work programs each with specific frequencies and times for a specific face area Program 3 Acts on the temporal region and the forehead in general Program 4 Acts on the chin and all around the mandibular arch The same program is also used to stimulate the neck muscles Program 1 Acts on the cheek bone area as far as the area bordering on the ear Program 5 Acts on the orbicular region and on the bags under the eyes Program 2 Acts on the cheek from the corner of the mouth to the jaw WORK PHASES Tua TRE ND Face programs consist of 2 work phases treatment active recovery At the end of each work phase TUA TRE ND automatically switches to the next phase and indicates this transition by means of an int
32. wn in the photo 2 channels 4 electrodes Always keep to the indicated polarity GREY AND BLACK 13 e DORSAL AREA Relaxation and toning of back muscles The vertical movement of the electrodes to adjacent positions makes it possible to successfully exercise all the back muscle Programs Muscles involved 6 RELAX LATISSIMUS DORSI 2 TONE Take up the position shown in the illustration Seated or prone Position of the electrodes on the body as shown in the photo 2 channels 4 electrodes Always keep to the indicated polarity GREY AND BLACK 44 45 A ae I X 3 2 Ze Z G 9 Ca Zz e I T A i Q OQ T gt a e aa 14 CERVICAL AREA De contraction and relaxation of the cervical area Program Muscles involved 6 RELAX CERVICALS Take up the position shown in the illustration Seated or prone i Position of the electrodes on the body as shown in the photo 2 channels 4 electrodes Always keep to the indicated polarity GREY AND BLACK 15 PELVIS AND HIPS Treatment of the lumbar area and slimming of hips The muscles must work isometrically Programs Muscles involved 1 SLIM PELVIS AND HIPS 2 TONE 3 LIPOCELL DA Take up the position shown in the illustration Prone position AN Position of the electrodes on the bodv as shown in the photo 2 channels 4 electrodes Alway