Home

Manual_LogicS_English Rev6

image

Contents

1. 12 Hook the control unit onto the screws you have just inserted 13 Slide the unit onto the mounting plate as far as it will go ensuring that it fits properly on the plate 14 Tighten the last two screws properly Figure 7 Step 12 13 14 Page 13 36 3 Commissioning Commissioning involves the procedures required to ensure that the height of an electric height adjustable desk can be adjusted with the LogicS control unit Requirements for commissioning e The LogicS control unit must be mounted as described in section 2 e The table legs for adjusting the desktop must be mounted Danger only qualified technicians may commission the control unit Qualified technicians have the necessary electrical engineering training and are familiar with this user manual 3 1 LogicS sockets The LogicS control unit LogicS 3 can drive three motors has the following sockets Figure 8 Sockets Motor socket 1 M1 Motor socket 2 M2 Motor socket 3 M3 Handswitch socket HS Pinch protection strip socket see 3 2 3 Mains socket Cable lug for earthing the desk frame optional Connector for mains cut off optional OYOANSOOWO Page 14 36 3 2 Commissioning procedure To commission a LogicsS control unit proceed as follows 3 2 1 Connect drives Plug the motor cables into the relevant 8 pin motor sockets M1 M2 and M3 Note when connecting the motor cables you must strictly adhere t
2. User manual Control Unit for an Electric Height Adjustable Desk LogicS 2 LogicS 3 Rev 6 Subject to change without notice Errors and omissions excepted LOGICDATA cannot accept responsibility for incorrect operation or use of the products other than for the intended purpose Under the warranty terms LOGICDATA shall replace or repair any products that prove defective at the time of delivery LOGICDATA shall not assume any further liability If you have any questions or special requests please contact LOGICDATA direct 2009 LOGICDATA www logicdata at LLI Li 7 OC O gt OC O LL A O E O A LOGICDATA MOTION FOR YOUR LIFE LOGICDATA Electronic amp Software Entwicklungs GmbH Wirtschaftspark 18 A 8530 Deutschlandsberg Austria Tel 43 0 3462 51 98 Fax 43 0 3462 51 98 530 e mail office logicdata at 4 Se De f A TO 2 m i i ee tr Contents FNC HACE 00 POOL E ners 4 i Fy Is AAA 4 1 2 LogicS 2 LogicS 3 control unit functionality o ccooocccconnnnnoncnnnnnnnnnnncnnos 4 1 3 Target group and previous knowledge oooccconccconccconcnconcnconcnconcnconcncnncnnonens 5 1 4 Differences in LogicS 2 LogicS 3 control unit performanCe oooccccnno c 5 1 5 Symbols used in safety instructions cccoccccoccnnconcnnccnnnnonannnonanononanonnnannnss 5 16 ISP Intelligent System Protec HONN a a a a a E 6 A e KIGE COMEM E a eee gs aene te s
3. eel Press the required memory position key e g 2 and hold it down The desktop will move until it reaches the saved position If you release the key before the saved position is reached the desktop will stop and the saved desktop position will not be reached The desktop has reached the saved position Now release the memory position key The display will read the current saved desktop position Option B with double click function 1 2 Te y A O Double click the required memory position key e g 2 After the double click the desktop will automatically adjust to the saved position E y 4 The display will show the current Saved desktop position Danger when you change the desktop position automatically especially without using pinch protection there is a higher risk of pinching You must therefore ensure that no people or objects are located in the hazardous area or reach into it Note if you press another key while the desktop is changing automatically to a saved position it will stop immediately You then have to reactivate automatic desktop adjustment to a preset position LOGIC Page 19 36 4 2 3 Changing the desktop height displayed This function enables you to change the height shown on the display but not the actual position of the desktop Proceed as follows Press the memory key The display will read S 2 Press the desktop down key down arrow for approx
4. 17 36 4 2 Advanced functions Note you can only use the following functions of the LogicS control unit if you have a handswitch with memory position keys and a memory key 4 2 1 Saving a desktop position This function allows you to save a defined desktop height One desktop height can be saved per memory position key To save a position proceed as follows Note if you are switching on the LogicS control unit for the first time all the saved positions are set to the lowest desktop height minimum desktop position bh Adjust the desktop to the position you want to save The display will show the desktop height e g 73cm 2 Press the memory key The display will read S 3 Press the required memory position key e g 2 The display will read 2 4 The set desktop position will now be saved to the selected memory position key You will hear an audible double click and after about 2 seconds the saved desktop position will be displayed Note the design of the memory position keys varies depending on the handswitch model used Page 18 36 4 2 2 Adjusting the desktop to a saved position You can use this function to adjust the desktop to a saved height To change to a saved position proceed as follows Note availability of the double click function depends on the software configuration of the control unit Option A without double click function je Te Be
5. 5 seconds The display will start flashing 3 Adjust the height displayed by pressing the desktop down down arrow or desktop up key up arrow 4 Press the memory key The height display is now set to the new desktop position entered Note please note that this procedure does not alter the actual position of the desktop It only changes the height displayed 4 2 4 Manual reset When the actual desktop position no longer corresponds to the height displayed or you wish to use a configured control unit on another identical electric height adjustable desk you have to reset the lowest desktop position to the minimum height 1 ow Press the desktop down key Keep pressing it until the desktop has reached the lowest position programmed desktop position e 4 Press the desktop down key again and keep pressing it After about 5 seconds the desktop will slowly move further down until it reaches the absolutely lowest desktop position possible 3 Release the desktop down key The electric height adjustable desk can now be used again normally Danger intelligent system protection ISP is not enabled during all resets and limit position calibration Please note that there is a potential risk of pinching in this case LOGIC Page 20 36 4 2 5 Enabling limit position calibration The service technician enables limit position calibration during the commissioning procedure Note availability of the S 7 func
6. PO D Note for reasons of EU conformity and product safety we advise you to provide users of your products with a manual in the relevant EU language Note when you ship your finished products enclose a user manual containing all the safety instructions that consumers need to handle your product safely Note the user manual for your finished product must contain the following note you must read the user manual before you operate the product electric height adjustable desk Advise your customers that the user manual must be kept at hand in close proximity to the product electric height adjustable desk Danger conduct a risk analysis of your product electric height adjustable desk so that you can respond to any potential residual risks e g by changing design features or adding notes to the user manual and or placing warnings on your product Note ensure that no unauthorised individuals e g small children people under the influence of drugs etc can tamper with your product or the control unit Important note for service Danger only use original spare parts Parts may only be replaced by qualified service technicians otherwise the warranty guarantee shall be null and void Danger in the event of a fault please contact customer service immediately Only original spare parts may be used for repairing the control units Parts may only be replaced by qualified service technicians otherwise the warranty guarant
7. 36 1 Preface Dear Customer Thank you for choosing a LogicS 2 LogicS 3 control unit for electric height adjustable desks from LOGICDATA Electronic amp Software Entwicklungs GmbH You are now in possession of a state of the art product that complies with all the relevant safety requirements 1 1 Intended use LogicS 2 LogicS 3 control units may only be used for the intended purpose i e to control electric height adjustable desks Only motors that meet LOGICDATA specifications may be used to drive the lifting devices The control units must be installed put into operation and their function checked by qualified personnel Using them to control other motors or installing them in products other than electric height adjustable desks is only permissible with the prior written consent of LOGICDATA Their basic function is upward and downward adjustment of the desktop which can be controlled with all the handswitches available 1 2 LogicS 2 LogicS 3 control unit functionality The LogicS 2 LogicS 3 control units incorporate the following features the availability of some of the features depends on the handswitch used e Control units are available for various mains voltages e Awide selection of LOGICDATA handswitches Is available for the control units e Additional functions are available depending on the handswitch model used e g saving desktop positions adjusting the desktop to saved positions etc ISP Int
8. age as specified on the type plate LogicS control units are also available for the mains voltages used in other countries The above values do not apply to them but you will find detailed information in the relevant user manual Caution only use the power cord supplied with the control unit Check that it is not damaged Do not ever operate the LogicS control unit if the power cord is damaged Caution before connecting and disconnecting handswitches you must unplug the power cord Caution in the event of a malfunction e g if the control unit keeps adjusting the desk because a movement key has jammed please unplug the unit immediately Danger do not expose the LogicS control unit to moisture drips or splashes PPPP bb Page 8 36 PP gt ooe bP Danger when changing the desktop position especially without using pinch protection there is a risk of pinching You must therefore ensure that no people or objects are located in the hazardous area or can reach into it Danger when changing the desktop position there may in exceptional cases be a risk of pinching in spite of the safety features You must therefore always ensure that no people or objects are located in the hazardous area or reach into it Danger do not modify or make any changes to the control unit the controls themselves or handswitches Danger do not operate the LogicS control unit in a potentially explosi
9. drill template and mark the drill hotels on the desktop e Page 35 36 7 Further information 7 1 End of life disposal When you no longer require the LogicS control unit please note the following for disposal 7 2 Manufacturer LOGICDATA Tel 43 0 3462 5198 O Electronic Software Entwicklungs GmbH Fax 43 0 3462 5198 530 Note ensure eco friendly disposal of all the control unit components separate the plastic and electronic parts for collection Also ensure eco friendly disposal of all the other components pinch protection strip drives cables etc Wirtschaftspark 18 E mail office logicdata at 8530 Deutschlandsberg Austria http www logicdata at Page 36 36
10. e also sealed in plastic film To unpack proceed as follows ile 2 3 4 Remove the cardboard and plastic film from the control unit components Check the package contents Dispose of the packaging materials Keep the user manual at hand for the operators Note ensure eco friendly disposal of the packaging materials separate the plastic parts and cardboard for collection Page 7 36 Se i i an 1 9 Safety instructions This user manual contains safety instructions that draw your attention to any possible risks thus enabling safe operation of the LogicS control unit Please observe these warnings and instructions at all times In this section you will find general safety instructions that do not refer to any particular steps or procedures You will find the work specific safety instructions in the relevant section of the manual Additional warnings are given on the LogicS control unit itself 1 9 1 General safety instructions Note you must read the user manual carefully before installing or operating the LogicS control unit Caution do not open the LogicS control unit under any circumstances There is a danger of electric shock Caution the LogicS control unit is not designed for continuous operation Changing the desktop position without interruption must not exceed the duty cycle indicated on the nameplate Caution the LogicS control unit may only be operated with mains volt
11. ed in the following error LogicS control unit list AAA No fault No fault o Switch the control unit off Contact customer service 06 M1 MOS FET is defective Switch the control unit off Contact customer service 08 ____ M3 MOS FET is defective 09 M4MOS FET is defective 11 Short circuit in M1 motor Unplug the control unit socket Fix the external short circuit 1 Short circuit in M2 motor Start the control unit again socket 2 13 Short circuit in M3 motor socket Lae circuit in M4 motor socket e circuit in M5 motor socket Plug a motor into the corresponding socket socket socket socket socket socket Contact customer service Page 31 36 A COGICDATA MOTION FOR TOUR LIFE 6 3 Optional products The following optional products are available for LogicS control units Note you can only use some of the LogicS control unit functions if the optional product is installed 6 3 1 Pinch protection strip The pinch protection strip is attached to the electric height adjustable desk lf anything e g leg object comes into contact with the strip while the desk is moving the control unit will stop the desktop immediately and move it to a safe position with the drive back function operation Caution ensure that the pinch protection strip is always plugged into the Caution the pinch protection strip is equipped with cable break monitoring Do not therefore unplug the pinch protection st
12. ee shall be null and void Page 10 36 2 LogicS installation instructions Mount the LogicS control unit on the underside of the desktop You will need the following tools for mounting e Cross tip screwdriver e Pencil e Drill for boring holes Caution the power cord must be unplugged while the LogicS control unit is being mounted To mount the LogicS control unit proceed as follows 1 Attach the mounting plate and position the control unit where you want it under the desktop 2 Mark the edge of the mounting plate with a pencil Note we recommend using the drill template to help with mounting You will find the template on page 35 If you do not wish to use it please follow the mounting instructions carefully Figure 2 Step 2 3 Remove the mounting plate again 4 Align the mounting plate along the pencil line and mark the two drill holes with a pencil 5 Pre drill these two holes i LOGIC Page 11 36 N o Figure 3 Step 6 Note the mounting plate is wedge shaped see Figure 3 7 Hook the LogicS control unit onto the mounting plate sliding it in as far as it will go N ASA Figure 4 Step 7 8 Mark the drill holes for the mounting link with a pencil Figure 5 Step 8 Page 12 36 9 Remove the control unit again 10 Pre arill these two holes 11 Screw the remaining two screws halfway into these two holes Figure 6 Step 11
13. elligent System Protection Configurable stop conditions overtemperature overcurrent timeout limit switch Configurable reset conditions Variable duty cycle Mains cut off with variable switch off time Two definable motor groups Automatic motor detection PLUG DETECTION function Up to six memory positions Additional pinch protection with optional pinch protection strip DRIVE BACK function for various conditions AUTO MOVE function FLEX MEMORY with random function SIT STAND memory Page 4 36 UT OZ i E 1 3 Target group and previous knowledge This user manual addresses the following people e Technicians who assemble and put electric height adjustable desks into operation by installing motors and control units configuring control units etc e Furniture assembly service and maintenance personnel who put electric height adjustable desks into operation in showrooms or at the customer s The following is required for installing operating and configuring electric height adjustable desks with LogicS control units AE e Basic mechanical and electrical skills with suitable qualifications e Reading the user manual 1 4 Differences in LogicS 2 LogicS 3 control unit performance LogicS 2 he LogicS 2 control unit can be used with up to 2 motors for electric desk height adjustment LogicS 3 The LogicS 3 control unit can be used with up to 3 motors for electric desk height adjustment Note for fur
14. ete den eae tate steams earn amen ences 7 TEC WIAD ACKING a a UPN sient vant santasu nus sincuametaersaNesayesiiauyaneain 7 a A 8 1 9 1 General Safety InStructiONS ccccoccncccnnncoccnnccnnnnononnnonacononannnnnnnnnnnncnnss 8 LI O eee eee oa eee eee eee oeeeeeeen eee 10 LO im portanl MOteTORSCIVICE ma aa a a annstractuaneenctens 10 Logics installation INSTRUCTIONS 2 lt lt lt lt c2 lt sc00 cececesscensceeereeeceescenereseseresereseseneceese 11 COMMISSIONING e e Sect Secrest E teere garden teens sere ieee eter ete 14 Sal LOGICS A no e 14 32 Sommissionind Procedures eesti saetee eens eee ee 15 32l Conmec GV CS a a a ao oo 15 22 2E Onmeda econo ee ones 15 3 2 3 Connect Optional components e ee e a 15 S24 CONNEC tman SUPON a siendo 16 3 2 5 System configuration examMple oocccccccccccccnccconocococononanonnnncnonononoss 16 Operating tnerlkoGic CONTOU a a ias 17 AVA SE ASICMUMNCIIOMS APA O mua nae rosin mmny ovntaan nrani tre rene need 17 4 1 1 UpWara desktop MOVE IMME Ile ss 2 eccerezssesas scars E eos 17 4 1 2 Downward desktop MOVEMENM cccccccssccssssesseseseeseseeseneeseseeseneaees 17 42 Advanced cae sceee sence rey cssencenesesayecu EEEE EEE EEEE EEEE EEE EEE EE EEEE EEEE 18 4 2 1 Saving a desktop POSO reee A ora od a eee 18 4 2 2 Adjusting the desktop to a saved POSITION occcoccnccccnccncnccncncnncncnnos 19 4 2 3 Changing the desktop height displayed cooocccconcccconcnnconc
15. me time Keep the key combination pressed for about 10 seconds Then release the keys The display will read S O 2 Press the desktop up key until the display reads S 6 The display will show S 6 3 Press the memory key The display will show 002 4 ay Te HA Now enter the required key combination to unlock the handswitch e g T1 12 and 14 Page 25 36 2 UOGICDATA MOTION FOR YOUR LIFE hem E F 1 os TN da I l F f del AP 1i o Uia weet i 4 3 6 Mains cut off The mains isolation function causes the power supply to the control unit to switch off automatically 20 seconds after it is last used the time can be configured by computer This function plays a significant role in reducing electric smog Requirement for the mains isolation function The mains cut off cable with a 3 pin socket must be connected to the power cord Note this 3 pin socket must be in contact with the mains cut off plug on the control unit The function must be configured using the software Figure 10 Mains cut off 4 3 7 Safety area This function triggers a safety stop at a defined desktop position configured with the software The safety stop functions as follows 1 y Press the desktop down key and hold it down The desktop will move to the start of the safety area The desktop movement will stop just before the safety area Press the desktop down key again The desktop will then move
16. n between the mechanical and electronic systems that is A responsible for cutting out the motor In addition the mechanical components motor and ambient conditions all affect cut out sensitivity As the control unit manufacturer LOGICDATA cannot therefore eliminate this residual risk completely or accept any liability Please note the following for maximising ISP functionality To ensure the best possible pinch protection a mechanical brake must be fitted that is applied when the electric height adjustable desk moves down Note without a mechanical brake cut out sensitivity may be reduced under load However if there is no load on the desktop ISP will function properly even without a brake Note as soon as ISP has stopped the electric height adjustable desk from moving you can then only adjust the desktop in the opposite direction the safety feature initially prevents you from adjusting the desk in the same direction as triggered it Page 6 36 E l 2 UOGICDATA MOTION FOR YOUR LIFE 1 7 Package contents The LogicS control unit is supplied together with the following components as standard D Figure 1 Package contents LogicsS control unit with mounting link Mounting plate Power cord Note for detailed information on optional control unit components and accessories see page 32 1 8 Unpacking The LogicS control unit comes packed in a cardboard box Some components ar
17. nit model see technical data Ser No Revision LogicS 3 KTT 360VA NE 32452988634552 0 24 Input Output Duty Cycle 230VACISOHZ 2A esovarsavoc 1A 1min 9min LOGICDATA Sc Type Figure 11 Nameplate Page 29 36 6 Appendix In this section you will find detailed information on the following topics Possible faults and remedies Error messages on the handswitch display Optional products Drill template 6 1 Possible faults and remedies Drives not working Power cord is not connected Plug the power cord into the control unit Drives are not connected Plug the motor cables into the control unit Poor plug contact Plug the motor cables power cord and handswitch in properly Control unit is defective Contact customer service Handswitch is defective Replace the handswitch Drives only operating in one direction Drive is defective Control unit or handswitch not working Control unit is defective 6 2 Error messages on the handswitch display H The display reads HOT gt The LogicS control unit is fitted with Wait until the control unit has cooled down overheating protection Overheating and HOT is no longer displayed The LogicS has caused it to stop the control unit control unit is then operational again L The display reads E an error code Page 30 36 A COGICDATA MOTION FOR TOUR LIFE There is an internal fault in the Proceed as indicat
18. nnononons 20 424 Man alresSel serena ersten E S E ado 20 42 SENAN DOSON CAIDO a a nino sana eee 21 A2 A a A A a teens iereniye saneens 22 4 3 Software dependent tUnctions ma r aa aa 23 4 3 1 Reset after POWER ON cccccccceeccceseeceeeeceeeeceueeceueeseeeseeeesseeenees 23 Ae sSIOW Speed Tanges a a a tae 23 A433 A on ie see ed omen eaten an sa enneaaetanre nee 23 4 3 4 Flexible desktop POSITIONS cccoocccoccnconcnccncncnncnconononncncnncnonnrnconenonnnos 24 Aor LPN COC Cees e see cae cesses e EE Oe 24 ASO INNES CURO santos eee seen ee een eee See ee 26 Aol Li A des y AAA o 26 o tener meri erie mete enero ner omer gu nee ner eerie ere meee eee 27 4 3 9 DIVE BACK 27 4310 Auto detect number o Aves oea e cae 27 d oa OMY CY cie MOI IO ANG a a a stamina rlaneucauiuaeinecennn craxtuaeounetans 27 Page 2 36 A COGICDATA MOTION FOR YOUR LIFE ooo ae 28 A PADD CINGIN OPPPPROA oUo PP tans one one saree enennnciee dee unamtnemumeaueeunectaerune an cnaceanean 30 6 1 Possible faultS and tremedies oeer an 30 6 2 Error messages on the handswitch display coooccccocccnonncnncncnnonnnnonoss 30 67 OplionalProquUElSe errors cern ee ads 32 6 3 1 PINCHA PIO ECHO MS Monaco ra daa a aaa DEE 32 A A e ech eck 33 A dl a e PPM o o rae rorieer conan cm irireperonene ema 35 Le URNerniMNMoO Malo oras ee os a ee 36 7a o a A 36 TS da Vit 10 AAPP tance seen acres es eee ieee ieee ren ree heer 36 _Page 3
19. o the sequence M1 M2 M3 3 2 2 Connect handswitch Plug the handswitch into the 7 pin socket HS Note you can choose from a wide range of LOGICDATA handswitches for the LogicS control unit For technical data on the handswitches see page 33 3 2 3 Connect optional components lf your control unit has an earthing cable attach it to a metal part of the desk lf your unit has an optional pinch protection strip plug it into the SL socket Danger to ensure correct functioning of the pinch protection strip it must be installed by an authorised technician lf you wish to use a mains cut off plug it into the connector see also page 26 Page 15 36 3 2 4 Connect mains supply Caution before you plug in the power cord check the following again e The mains supply voltage must be as specified on the type plate A e All the components must be plugged into the right sockets e The earthing cable must be connected When the power cord is plugged in the LogicS control unit is operational 3 25 System configuration example The figure below shows the socket assignment for a configuration example This configuration consists of 1 LogicS 3 control unit 3 motors hidden in the table legs HSU MDF OK LD handswitch 1 pinch protection strip OOOO Figure 9 Configuration example Page 16 36 J p cel Se i m TS a m LN t s dl Th f 4 Opera
20. rip during A appropriate socket on the control unit Page 32 36 6 3 2 Handswitches LOGICDATA supplies various handswitch models with different features The following handswitches are compatible with the LogicS control unit family Note HSX OD 2 LD HSE MDF 2 LD HSU OD 2 LD you will find detailed information on the LOGICDATA handswitches in a separate product catalogue Simple handswitch with movement function e Rugged e Cost effective e Compact size Inlay handswitch with movement function e Easy to install e Display e Mounted on the desktop Standard infrared remote control e No cables Ergonomic housing 16 channels 2 motor groups 6 memory positions Simple handswitch with movement function e 2keys e Silver e Soft touch keys Page 33 36 i LOGIC HSU MDF 4M2 LD HSM OD 2 LD __ HSF MDF 4M4 LD Handswitch with display without memory function e 2 movement keys e Display e Silver e Soft touch keys Handswitch with display and memory functions e 5 memory keys 2 movement keys Display Silver Soft touch keys Competitive price Compact size Ergonomic design Soft touch keys Flat design Display with status indicated Soft touch keys Mechanism slides the handswitch completely under the desktop e Precision display to 1 10 inch or cm Page 34 36 A LOGICDATA MOTION FOR YOUR LIFE 6 4 Drill template Cut out the
21. the number of drives detected 4 3 11 Duty cycle monitoring Duty cycle monitoring means that when the control unit has been operating for a defined period it is switched off for a set time e g after 2 minute of continuous operation the control unit is automatically disabled for the next 18 minutes Page 27 36 B Technical data General Supply voltage 230V 6 50HZ 1 1W 5VDC 5 150mA 5VDC 10 150mA 0 35 C 5 85 non condensing 5 90 non condensing Protection class without earth terminal ME Dimensions L x B x H mm LogicS 3 XXX 360VA Switching capacity 10 1 min on 9 min off 26kg o Weight 2 6kg LogicS 3 XXX 340V A Switching capacity 5 30 sec on 9 30 off 2 2kg oo Weight 2 2kg LogicS 2 XXX 340V A Switching capacity 10 1 min on 9 min off 24kg o Weight 2 1kg LogicS 2 XXX 240V A Switching capacity 10 1 min on 9 min off WG Weight 1 9kg LogicS 2 XXX 140VA Switching capacity 10 1 min on 9 min off 140VA 6A 24V 25 C Switching capacity 5 30 sec on 9 30 off 160VA 7A 22V O 25 C Switching capacity 10 1 min on 9 min off 11A up 3A down Weight 1 4kg Page 28 36 da mr i sa gt om T gt p w SS M I x k a Dom Nameplate The figure below shows the nameplate and its location on the control unit Note the details on the nameplate depend on the LogicS control u
22. ther differences please refer to the data sheets on the LogicS 2 and LogicS 3 control units http www logicdata at 1 5 Symbols used in safety instructions This user manual contains safety instructions with symbols drawing your attention to possible dangers and residual risks They indicate the following Danger this warning symbol advises you of imminent danger to people s lives and health Failure to observe this warning may result in health problems serious injuries and damage to property Caution this warning advises you of possible dangers from electric current Failure to observe this warning may cause injuries and damage to property Page 5 36 lt a i am Note this symbol advises you of important information that must be noted for operating the LogicS control unit safely Danger this warning advises you of a possible risk of body parts being trapped or pinched in exceptional cases Failure to observe this warning may result in health problems serious injuries and damage to property Note you must read the user manual 1 6 ISP Intelligent System Protection ISP is an electronic state of the art protection system developed by LOGICDATA It also substantially reduces the risk of fingers being trapped or pinched Danger in spite of ISP being in place there may still be a risk of pinching in exceptional cases as it is not only the control unit but also the interactio
23. ting the LogicS control unit To ensure safe operation of the LogicS control unit please observe the following safety instructions Caution keep children away from electric height adjustable desks control units and handswitches There is risk of injury and electric shock Caution unplug the power cord during a thunderstorm or if you do not intend to use the desk for a longer period The control unit might otherwise be damaged by power surges Basic functions Note the LogicS control unit offers an extensive range of functions The availability of some functions depends however on the handswitch used This section describes the basic functions available with every handswitch designed for use with LogicS control units gt D 4 1 1 Upward desktop movement This function enables you to adjust the desktop upwards To change its position proceed as follows A Press the desktop up key Keep pressing the key until the required desktop height is reached Note the desktop will continue moving upwards until you release the key or the maximum height is reached 4 1 2 Downward desktop movement This function enables you to adjust the desktop downwards To change its position proceed as follows y Press the desktop down key Keep pressing the key until the required desktop height is reached Note the desktop will continue moving downwards until you release the key or the minimum height is reached LOGIC Page
24. tion depends on the parameters set for the control unit 1 1 72 A Press the keys memory position 1 2 and desktop up E at the same time Keep the key combination pressed for about 10 seconds Then release the keys gt _ The display will read S O L Press the desktop up key until the display reads S 7 No LM pH The display will show S 7 Press the memory key Page 21 36 4 2 6 Limit position calibration The limit positions must be calibrated during commissioning after the control unit has been installed Note there is the option of having all the settings required for commissioning carried out at the factory To calibrate the limit positions proceed as follows TS 158 2 y 3 q 2 4 A CEB UN 6 m 2 068 flashes on the display Press the desktop down key until the desktop reaches the lowest position Set the current desktop height on the display Press memory position key 1 to increase the desktop position displayed movement locked in every direction Press memory position key 2 to decrease the desktop position displayed movement locked in every direction Press the memory key 088 will flash on the display Press the desktop up key until the desktop reaches the highest position set the current desktop height on the display Press memory position key 1 to increase the desktop position displayed Press memory posi
25. tion key 2 to decrease the desktop position displayed Press the memory key The display will show the current desktop position display no longer flashing Danger intelligent system protection ISP is not enabled during all resets and limit position calibration Please note that there is a potential risk of pinching in this case LOGIC Page 22 36 4 3 Software dependent functions 4 3 1 Reset after POWER ON After every POWER ON e g plugging in the power cord the following reset procedure is carried out Note prior to shipping the LogicS control unit is parameterised with the software The following functions are only available if the control unit has been configured accordingly 1 x The desktop up function is locked the desktop up key has no function during this phase c y If you press the desktop down key the desktop will move at half speed to the lowest position 3 Normal operation is now possible again Danger intelligent system protection ISP is not enabled during all resets and limit position calibration Please note that there is a potential risk of pinching in this case 4 3 2 Slow speed ranges This function low speed automatically slows down the desktop during adjustment before it reaches the following positions e Highest and lowest desktop positions e All saved positions 4 3 3 Auto Move From an ergonomic point of view it is advisable to change your desktop height reg
26. to the lowest position Note you cannot save desktop positions in safety areas Page 26 36 4 3 8 Plug detection The LogicS control unit can detect whether a motor is plugged into the relevant socket In addition the control unit detects whether a motor has been replaced this function depends on the motor used 4 3 9 Drive Back Note the Drive Back function is only enabled if the ISP intelligent system protection or a pinch protection strip is used After a safety function is triggered by ISP or the pinch protection strip the desktop automatically moves a defined distance in the opposite direction This immediately prevents any possible risk of pinching Danger in spite of ISP being in place there may still be a risk of pinching in exceptional cases as it is not only the control unit but also the interaction between all the components in the electric height adjustable desk that is responsible for cutting out the motor In addition the mechanical components motor and ambient conditions all affect cut out sensitivity As the control unit manufacturer LOGICDATA does not have an effect on this residual risk and cannot therefore accept any liability Please follow the safety instructions in the manual and treat our product with due care 4 3 10 Auto detect number of drives During every reset the control unit checks how many drives are connected It then automatically configures itself to
27. ularly The Auto Move function reminds the person using the electric height adjustable desk to change the desktop position It consists of a brief UP and DOWN movement of the desktop Note the time interval for the reminder function is configured using the software LOGIC Page 23 36 4 3 4 Flexible desktop positions This function is also an ergonomic feature It changes all the saved desktop positions slightly at random The function is available for e The last previously set highest and lowest desktop positions e All saved desktop positions Note the range for varying the saved desktop positions at random is configured with the software 4 3 5 PIN code The PIN code function locks the handswitch This means that all handswitch functions are disabled e g adjusting the desktop to a saved position saving a new height position etc Locking with PIN code Press the memory key until the control unit clicks twice and the display reads 001 The display shows 001 The control unit handswitch operation is then locked Unlocking with PIN code To unlock the control unit enter a 3 digit key combination with the position keys Note the default key combination is 1 2 3 to enable it quickly press position keys 11 12 T3 one after another Page 24 36 Ti ey I Ne a le Changing the key combination 1 4 2 A Press the keys memory position 1 2 and desktop up r H at the sa
28. ve atmosphere Danger in the event of a fault motor or component whenever the desktop attempts to adjust the height it may move slightly before the safety cut out is triggered Please note that there is a potential risk of pinching in this case Danger intelligent system protection ISP is not enabled during all resets see 4 2 4 and 4 3 1 and limit position calibration 4 2 6 Please note that there is a potential risk of pinching in this case Danger this device is not intended for use by individuals including children with limited physical sensory or mental abilities or with a lack of experience and or lack of expertise unless they are supervised by a person responsible for their safety or have received instructions from that person on how to use the control unit Danger children must be supervised at all times to ensure that they do not play with the control unit Danger if the control unit s power cord is damaged it must be replaced by the manufacturer or customer service or similarly qualified person in order to prevent any risks Note only clean the LogicS control unit with a dry or slightly moist cloth Before cleaning you must always unplug the power cord Page 9 36 a i an 1 9 2 Important notes for OEMs What we mean by OEMs are companies that purchase LogicS control units from LOGICDATA and install them in their own products e g electric height adjustable desks gt

Download Pdf Manuals

image

Related Search

Related Contents

SEATING OPERATING INSTRUCTIONS  accord de sous-traitance pour la realisation de preparations  取扱い説明書(駐車場・庭用)  Samsung RM25JGRS1 manual do usuário  PDFダウンロード(19MB  

Copyright © All rights reserved.
Failed to retrieve file