Home
automatic door m200
Contents
1. 200 2200 2200 gt h Page 12 Fb Am Fa u m Automatic Door M200 AIKAA English 7 Door Leaf Hanging To adjust the leaves follow the steps below 1 Loosen the screw A to lower the support in relation to cradle 2 Hang the door leaf in the profile 3 Ensure that the nylon wheel of the cradle will roll down right along the curve track Cradle Height adjustment screw C Pressing Wheel Screw D Single door leaf type Bisection type Cradle parts Cradle parts Cradle parts Cradle parts Cradle parts Cradle parts Page 13 Automatic Door M200 English 8 Door Leaf Adjusting Adjusting steps 1 Left and right side cradles should be installed in a straight line 2 After hanging the door leaf on the power beam check if the door leaf slides to left or right side 3 With the door leaf hung on the sliding guide it should be open and close by hand in order to verify If exists friction 4 The movable door leaf has to be hung vertically When the space between the movable leaf and the fixed parts is not desired you can adjust using screws D from the cradle See previous page When the movable door leaf are declining as the following diagram you c
2. 100W Motor Rated power Standby consumption Approximately 10W Functions Fully closed Fully open Partial open Automatic Entry exit only Working Temperature 30 C 50 C Page 05 2 Power Beam Sectional View Automatic Door M200 English 150 Aluminum profile type M0103 Length 4200mm or 5800mm 108 O IR 20 34 28 44 variable Leaf movement Until the center of the leaf In addition has the dimensions 170 to choose and match Pag 06 Automatic Door M200 English 3 Glass production Measures for drilling Fixing glasses 150 We recommend the use of tempered glass Page 07 Ya Am Fa u m Automatic Door M200 AIKAA English 4 Power Beam Component List The following components attached in the packing boxes oom Part Number Schematic Drawing Quantity EE Standard 4200mm Standard 4200mm Cradle parts M0401 M0501 Upper Connection Parts Lower Connection Parts M0502 Controller M0802 Door Halter M0601 M1201 Switch of power supply Page 08 4 Power Beam Component List Automatic Door M200 English The following components attached in the packing boxes Photocells Door guide M2125 Program Selector M CELE 01 Electric Lock M ELE 02 Electric lock controller module Page 09 Automatic Door M200 English 5 Power Bea
3. OUTSIDE RADAR PROGRAM SELECTOR CONNECTIONS CONNECTIONS 24 Red Oy Grey o pe O Da Red deg Brown gt 2 x o Yellow NO 5G og Orange gt 3 CU Yellow COM Sc Purple gt 4 the two yellow and red wires do Bo Blue Du not have specific positions as long s es Green 10 as they are connected like described White gt 7 above Black gt 8 I Red 9 LOCK SIGN MIS RADAREXT 9 8 7 6 5 4 3 2 1 36V P ov SELECTOR Vv I CONNECTIONS 12 24V gt 15V OV gt OV CH1 a gt OSIG CH1 b gt COM CH2 a OV CH2 b gt LSIG AN i INSIDE RADAR WITH PHOTOCELLS CONNECTIONS Black OV Green COM gt N21 Control gt N22 Control gt 15V Yellow NO Brown P Red T gt white ELECTRIC LOCK MODULE CONNECTIONS Yellow SIGN Red gt 36V Green OV K CONTROL BOARD CONNECTIONS Control n 3 gt 3ML Control nen 1 ML Control ne5 gt 5ML Control n 4 gt 14 ML Control n 9 9 ML Control n95 gt 15 ML Control n 1o gt 10 ML Page 18 English Automatic Door M200 N lt e n o l m O O A os fd cn 3 n 2 gt o O u O 0 lt pe hd O Q lt lt O O OUTSIDE RADAR CONNECTIONS i Red OV Red gt 15V Yellow gt NO Yellow COM the two
4. Automatic Door M200 English AUTOMATIC DOOR M200 KAPV SP KAPVE SP PLEASE READ CAREFULLY BEFORE ANY ASSEMBLY OR INSTALLATION VER 1 2 REV 02 2014 Automatic Door M200 English Warning to installer and user 1 Characteristics amp Technical Data Power Beam Sectional View Glass production Power Beam Device Component List Power Beam Installation Door Leaf Hanging Door Leaf Adjusting 2 3 4 5 Power Beam Parts Positions 6 7 8 9 Belt Tensioner Installation 10 Door Halter Installation 11 Connection Scheme 12 13 14 15 16 17 18 19 20 21 22 Emergency battery wiring scheme optional The installation of safety sensor optional Connections of all devices with the PCB ML Switch of Power Supply Control Device amp Motor Connection Bi Doors Inter locking Connection Diagram Program selector diagram Graphic Programming control unit Control System Functions Setting Connections Photocells module Connecting Microwave sensors The abnormal status amp the resolving methods pg pg pg pg pg pg pg pg pg pg pg pg pg pg pg pg pg pg pg pg pg pg pg 03 04 06 07 08 10 11 13 14 15 15 16 16 17 18 19 19 20 21 22 23 24 26 Page 02 Automatic Door M200 English Warning to installer and user 1 WARNING It s very important to your safety that this instructions are followed T
5. ILONd AFINVITV AONVAIV LV LYOd AHOINIAL IAHIILSIHILI VIVO ue vci Page 24 LIO Pa E ot one 3 60 O52U 92 ODNdO opini oe apepiunw 89 u 92x eun ajueleb T d 021U0 9 9 OJINDAID SOu UlI ABEIJUI ap X1 4 un eied ojol uo52 ap apepiun ewn 8 SINOLYI SIOU 2211 98 a pue je ndo o APunwwI 3U2 99 X ue sagjuerenb JINDIID 9IUONI9 I T H ulp q pasesui 104 JIUN JO4JUOD e SI SINOLYI 1914 9 9 Ps 19 1 0 IQINISIP Ep eniunwdWI euun o un sosHuese6 TTd Ono UOD elenaBbod eoSluol1 1 ossoJedjui OBBEI Ip auonsab ej Jad ejnjja20 01 eun 9 SNOLNO OYdIHISIA NOILdIHISIAA ANOIZINDS3AG er ALI NI A0VIN dI SVOVZINOHONIS SV INTIIOLO OTOYLNOD AC IVYLNII 11390 LOHd GAZINOYHONAS LINN 1IO0HLNO9 VIVZZINOHONIS VINTTIFIIOLOH OTIONLNOO Id VLINN VISCGOLOA SINO LIO Automatic Door M200 English 21 Connecting Microwave sensors 1 Generalinformation General information LED flashes after power on Sensitivity potentiometer lights up during detection JST connector Red 12 24V Power Supply Yellow Relay COM Planar antenna Relay NO for wide detection field KI The sensitivity settings determine the size of the sensing field vertical angle 30 mounting height 2 2m sensitivity maximum Page 25 Automatic Door M200 English Do not cover the Avoid vibrat
6. an adjust it relieving bolts A and B and turning the screw C 5 No friction is allowed on the movable door Attention No oil can be used on the sliding guide Cracks Leveling and adjusting leafs 1 Loosen the screws A and B from bracket 2 Turn the screw C to adjust height 3 Tighten the screws A and B after adjustment Screw D Page 14 Maftarvlina Automatic Door M200 AIKAA English 9 Belt Tension Adjusting 1 Check the tightness of the 4 screws F and G 2 Adjust screw D to reduce or increase belt tension 3 Belt may get prolonged after a long time of use In this case belt tension has to be renewed by repeating the above steps 1 and 2 Screw D Screw E Screw F Belt Ajusting Panel Limiter Switch of Power Supply 10 Door Halter Installation 1 Define the closing position of the door by installing the stopper 2 The position of the stoppers is as follows Single door leaf type e a ee ae le Door Halter Door Halter Door Halter DoorHalter Page 15 Pb Am Fa u m Automatic Door M200 AIKA T FELIS English 11 Connection Scheme WARNING All the connections should be operated under cutting off the 230V power supply Control Device OV Battery Accessories 36V Battery 15V Accessoies power supply 600mA Input for photocells NC Full opening terminal Functio
7. e 22 Automatic Door M200 English 19 Control System Functions Setting Adjust steps and warnings 1 Open and close the door for several times with hands before turning on the electricity to make sure there is no unconviniently during the process of opening and closing 2 If there is safe power you can enable disable according to K2 switch position 3 You must adjust the rebound force F according to door leaf s weight and running speed 4 When adjusting speed you must also adjust rebound force in order to avoid the door taking for meets barriers bounde to present repeatedly movement 5 At the beggining the opening time should be selected to the minute This parameter will be easier adjusted after the other parameters have already been selected A B C DE F Ki K K K Controller M0802 MOTORLINE K1 K1 button in ON by receiving signal from the radar the door will open and only will close after receiving a second pulse K1 OFF Automatic Mode The door opens to the 1st radar signal A Indicator light and closes automatically after expiry preselected pause time B Hand handling button Start C Door opening speed adjustment K2 If emergency battery present the switch K2 in ON D Door closing speed adjustment will keep the door open in case of power failure E Pause time adjustment 230V K2 OFF in the event of 230V power failure the F Rebound force adjustment the door remains closed K3 ON OFF Se
8. he bad installation or wrong appliance can damage people or materials 2 This product was designed and produced strictly for the use indicated in this manual Any other use then expressly mentioned may damage the product and or be a hazard to people and void the warranty 3 ELECTROCELOS is not responsible for the incorrect use of the product or by using other than that for which it was designed 4 Do not install the product in an area where there is danger of explosion gases or flammable fumes are a serious security threat 5 ELECTROCELOS is not responsible if the safety standards weren t taken into account in the manufacture of the element to be automated or any deformation that may occur at the same 6 Before the installation turn off the power 7 The devices ex photocells should be used for prevent injury in people or materials 8 ELECTROCELOS is not responsible for safety and proper operation of the product when isn t used components sold by itself 9 Do not make any changes to motor components and accessories 10 The installer should inform the customer of how to operate the product in an emergency case and provide the manual of it 11 Do not let children closer to the door when in motion 12 Keep controls out of reach of children to prevent any accident 13 You shouldn t in any circumstances attempt to repair or modify the equipment Must call a qualified technician for that job 14 The equipment should be insta
9. ions sensor 4 Troubleshooting Avoid moving objects in proximity of the sensor proximity of the sensor Revolve the potentiometer slowly with small strength Avoid HF lamps or fluorescent lighting in Avoid touching electronics SYMPTOMS PROBABLE CAUSES The door will not open and no red LED The sensor power is off lights up The door opens and closes constantly When closing the door creates vibrations picked up by the sensor The door will not close Red LED is OFF wrong position or faulty The sensor sees the door moving ON OFF switch at door control is in Improper output configuration 5 Technical specifications Technical specifications Technology Transmitter frequency Transmitter radiated power Transmitter power density Maximum mounting height Tilt angles Detection field mounting height 2 2m Detection mode Minimum speed Supply voltage Mains frequency Power consumption Output relay free of potential change over contact Max contact voltage Max contact current Max switching power Hold time Temperature range Degree of protection Norm Conformity Material Color of housing Dimensions Weight Length of cable CORRECTIVE ACTION Check the wiring and the power supply Increase the tilt angle and or reduce the sensitivity Make sure that the sensor is correctly fixed Reduce the sensitivity Make sure that the ON OFF switch for the door is in the ON or AUTOMATIC posi
10. lects the direction of the door opening K1 K2 K3 K4 in OFF condition default K4 Choosing closing force Page 23 English Automatic Door M200 m O O K O fd O K om n 0 lt p O O N CEL SHIN fai m LSVLNOD O N LOVLNOD DN aql QO O x m D O n m m g OHIINYIA day OSSON ALIHM OONVIE Q1AIHS ONYIHOS HOA 77 HOA ZL le 0S OHNYVD NIVD mom 001 OHNY NIY 3 C L OHIVAVUL VDININDIYI MYOM ADNANOAYS 0S 01 SOHNVD NIVD Spol puuo nv SEO sioop Inewo ny uoS neuuo ne Iod SIODVIITdV SNOILVIITddV INOIZWII1ddV ZL98 INN 339 98 68 WU 006 SOHTINZIAVIYI INI CIYVMHANI d00S SL ASL V 9G OA t 1VNOI9dO IVNOILdO SS dl 0 dl 20 HOA pz VI 31334 OLIVINOI LOVLNOD AVTAN DN ON SOJINIDAL SOGVG VIVA 1VIINHIAL ANYOANOD SIVAOHdd V V LINYOANOD OIILdO 3XI3d AVY TVIILdO OISOVYa OLIVINOI VAIVS LOVINOD LNdLNO JOLLVLNOS VLVLYOd VGIVS LNdLNOIWLIOSN OLNAWVNOIDNNSA 30 VUNIVHIdNIL FZUNLVHIdANIL ONILVYAdO IOLNANVNOIZNNA Id VANLVYAdWAL ALNAYYND LNFHYNI A TddNS OLNAWIGYOSSV OVSV LNAWIIV FDVLIOA ATddNS ANOIZVLNAWITV OYd59ILOYd 30 NVYHD NOILIILOHd JO FI3YDICIANOIZ
11. lled protected from elements such as water rain humidity or excessive dust 15 Equipment must be connected to earth ground 16 Equipment for indoor use only Page 03 Automatic Door M200 English 1 Characteristics amp Technical Data Intelligent Automatic Door Auto programmable and with adjustable parameters Low noise level Replaceable rubber guide base Firm movement ABS Braking Virtually no noise Auto reverse when hitting an obstacle Unic electronic motor lock Locking force of approximately 800N Lower Power Consumption Approximately 10W in Standby 36V brushless motor High efficiency high strength and long life Bi Door Interlocking One of the doors remains closed interlock between doors Program selector with 5 available functions Fully closed Fully open Partial opening Automatic Entry exit only Emergency Battery optional Allows emergency opening in case of 230V power failure Auxiliary functions Compatible with most access control systems Satin finish Adapted for varied climates Simple installation Objectives focused by the designer Reverses automatically when hiting obstacle in the path Security in first place Move Steadily Low noise level Page 04 Fb Am Fm u 5 Automatic Door M200 LLL LS FATES English 1 Characteristics amp Technical Data Type of Use Intensive Use AC230V 10 50 60Hz 1 20s Adjustable
12. m Parts Positions AII mounting parts position are basically as follows Single Door Leaf Type Belt Tensioner Lower Connection Parts Right Control Device Motor Device Upper Connection Parts Lett Sg I Door Halter Cradle Parts Belt Door Halter Switch of Power Supp Double Door Leaf Type Belt Tensioner Upper Connection Parts Lower Connection Parts Control Device Motor Device rm ins E 0 a Ga SPL Gua rar I ni O SE SIG i Th Cradle Parts Cradle Parts Door Halter Door Halter Switch of Power Suppl Page 10 ba Am F a u m Automatic Door M200 AIKA ZAI hh English 6 Profile Installation Surface Mounting The surface must vertically and horizontally leveled to ensure the proper functioning condition Set the M0103 profile to wall using at least 8mm screws 1 Make holes in the profile and in the wall in order to fix power beam Use a level to verify that the profile is perfectly level 2 Pay attention to the passage of electrical cables and signal in order to prevent them from being damaged by moving parts Profile End cover Not Standard Configuration Not Standard Configuration Page 11 PRG Automatic Door M200 E det English 6 Profile Installation POSSIBLE APPLICATIONS LA mm CN
13. n of Bi door Inter Locking Common Partial opening terminal Anti Panic Function Do not use For Future use only Do not use For Future use only Note Exit 6 and 7 are only for Anti Panic automatic glass doors If not using this function place a shunt between the 2 exits 12 Emergency battery wiring scheme optional py Controller Battery 36VDC The batteries are only for the following cases 1 Open the door automatically in case of 230V power failure 2 Electronic lock when closed for a limited time in case of 230V fault For this select K2 ON or K2 OFF K2 ON In the presence of batteries door opens automatically in case of 230V power failure K2 OFF In the presence of batteries door remains closed in case of 230V power failure Page 16 Fb Am F a v m Automatic Door M200 AIKAA English 13 The Installation of Safety Sensor optional 1 Make holes in the pillar making sure that holes will keep photocells lens in the same horizontal level Attention The mounting distance should be within meters Installation height is 600mm when Installation height is 300mm amp 900mm using single circuit when using double circuit Horizontal Line Connection Wire Pillar Page 17 English Automatic Door M200 Z Z O n 2 l m QO A O ia fd de gt N gt Q O t O a c Q fd Q O lt lt O O st q
14. nnection Controller Motor Device Switch of Power Supply o 0000 O l A o i a N 16 Bi Door Inter Locking Connection Diagram Double doors After the closing of one door another opens Inter Locking With this connection the 2 doors are never open at the same time Controller M0802 Page 20 Automatic Door M200 English Initialization Reset Button Screw fixed hole LED Fully Open Button Fully Lock Button Automatic Button Automatic D 3 4 Partial Open Partial Open Exit Only Button Unidirectional Screw fixed hole Frontal Panel Back Panel e Five range program selector e DC15 power input e Easy instalation and use e Function switch against password e With memory function in case of power failure e Instruction with indicator light to confirm operation validity as FULLY LOCK fee FULLY OPEN HALF OPEN Outdoor and indoor sensors are enabled Door only half open UNIDIRECTIONAL It allows to disable one of the microwave sensors according to direction AUTOMATIC Indoor and outdoor sensors are enabled Changing operation mode Press the FUNC key for 5 seconds Led indicator turns green Enter password original password is 1234 Reconfirm by pressing the FUNC button again Select the function you need from
15. of stoppers violently Faulty control board 1 Check the 230V power supply 2 Separate the door from belt and check if door can be moved by hand 3 Check fuse M1201 4 Make sure the cables are securely connected 1 Move the door manually without being attached to belt and verify proper operation 2 Repeat the previous step 3 Remove belt and check by hand if the movement is correct 4 Change the position of the potentiometers D and C see whether the unit changes the operation 5 Without the belt and without power make sure the motor turns manually 1 Unplug one radar one by one to see if the door close 2 Check if the cables connecting photocells module to control unit 1 and 2 close the circuit NO Install an shunt between point 1 and 2 and make sure the door close In case it closes verify power suplly cables 1 Remove obstacles in the area of the detection sensor 2 Adjust the sensor detection area and sensitivity 3 Align the photocells 4 Check moving leaves by hand where exists contact between components Check if the stoppers are tight and in place Change the position of the potentiometers C and D in order to see whether the switch changes control unit operation Reset control board by disconnecting batteries and 230V power supply for 5seconds Power on again the door will start new programming Page 2
16. the five available FULL LOCK FULL OPEN HALF OPEN EXIT ONLY AUTOMATIC Setting Management password Press the FUNC key for 10 seconds Selector will emit sound between 5 and 10s Enter correct password Reconfirm by pressing the FUNC button again Enter new password and press FUNC reconfirm the new password and pressing FUNC key New password setting completed successfully Note If you have forgotten your password open the rear panel and press the RESET button for 40 seconds The initialization of the system is confirmed by sounding a beep Password back to 1234 Page 21 Mafarvlina Automatic Door M200 LLL AAI English 18 Graphic Programming control unit After assembly completed open and close the door several times by hand before connecting to main power supply 230V in order to assure that there is no obstacle during opening and closing After checking the proper motion of the leaves can now move to the programming which is made automatically With the door closed connect to 230V power supply Note While E this operation do not pass in front of the microwave sensors Wait about 3 seconds Door will open and close at low speed Wait until door stops at close position The control unit stores automatically all process In case of controller receives an order from sensor or obstacle before finishing maneuver recognition it will repeat the whole process again Pag
17. tion Check the output configuration setting on each sensor connected to the door operator microwave and microprocessor 24 125GHz lt 20dBm EIRP lt omW cm Bom 0 to 90 vertical and 30 to 30 lateral 6m W x 3m D motion 5 cm s measured in the sensor axis 12V to 30V AC DC 30 10 50 to 60 Hz lt 2W VA 42V AC 60V DC 1A resistive 30W DC 60VA AC 105 257C lo 557C P54 R amp TTE 1999 5 EC EMC 89 336 EEC ABS black smoked aluminium finish 120mm W x 80mm H x 50mm D 0 265kg 2 5m Page 26 Automatic Door M200 English 22 The Abnormal Status and the Resolving Methods When the auto door unconventionally runs please cut off the power supply for a few seconds and then turn on again 1 Power failure 2 Door blocked 3 Damaged fuse 4 Cables desconnected The door cannot move 1 Leafs with friction Door open and close 2 Cradels with damaged bearings with very low speed 3 M0201Group tensioner with damaged bearings 4 Defective control unit 5 Motor with stuck reducer Door cannot be closed 1 Sensor sending continued signal 2 Photocells always open 1 There are obstacles in the sensor detection Door reverse direction ea o when closing 2 The door leaves are within the detection area 3 Photocells misaligned 4 There is friction in some door components Door leafs slam Lack
18. yellow and red wires do not have specific positions as long as they are connected like described above RADAREXT 9 8 7 6 5 4 3 2 1 SELECTOR OV 15V NO COM RADAR INT OV 15V NO COM f INSIDE RADAR CONNECTIONS Red gt OV Red gt 15V Yellow NO Yellow COM RECEIVER LSIG OV COM OSIG OV 15V ML RECETOR MR5 12 24V OV CH1 a CH1 D CH2 a CH2 D MR5 PROGRAM SELECTOR T amp O O gz CE O 3 O LOCK SIGN 36V 0V CONTROL 15 14 11 10 9 5 3 CONNECTIONS Grey s Brown sica Orange 3 Purple gt 4 Blue gt G Green Sai White o gt 7 Black gt 8 Red gt 9 CONNECTIONS 12 24V gt 15V OV gt OV CH1 a gt OSIG CH1 b gt COM CH2 a gt OV CH2 b gt LSIG ELECTRIC LOCK MODULE CONNECTIONS Yellow gt SIGN Red gt 36V gt Green O CONTROL BOARD CONNECTIONS Control ne3 gt 3ML Control nen gt 11 ML Control ne5 gt 5ML Control n 4 gt 14 ML Control n 9 9 ML Control n 15 gt 15 ML Control n210 gt 10 ML PHOTOCELL S MODULE CONNECTIONS Mod n 1 gt n 9 Control Mod n 3 gt n Control Mod n 2 n 1 Control Mod n 4 gt n 2 Control Page 19 ba Am Fa uv m Automatic Door M200 AIKAA English 15 Switch of Power Supply Control Device and Motor Co