Home
Expand existing, leased line, polled networks without
Contents
1. 1 DB25 F master port Indicators TL704A 11 LEDs 1 Power 1 SD 1 RD 4 Active 4 Stream TL708A 19 LEDs 1 Power 1 SD 1 RD 8 Active 8 Stream Environmental Operating Temperature 32 to 122 F 0 to 50 C Relative Humidity 5 to 95 noncondensing Altitude O to 10 000 feet Power 100 120 to 200 220 VAC 10 50 60 Hz 0 16 0 08 A external 110 220 volt select switch IEC power inlet 2 5 mm fuses Dimensions 1 75 H x 13 35 W x 9 D 4 44 x 33 09 x 22 86 cm Weight 4 5 lb 2 1 kg 724 746 5500 blackbox com Page 7 Chapter 2 Overview 2 Overview 2 1 Introduction The RS 232 Modem Sharing Device TL704A or TL708A enables the network manager to expand existing leased line polled networks without adding computer ports or communications links With the TL704A or TL708A up to four or eight terminals can share the same port and communications link using the contention and control protocols normally resident in the host hardware and software The device increases system and network efficiency through higher host processor use coupled with the significant decrease in idle time between host terminal traffic sessions Ideal for either synchronous or asynchronous network environments the MSD is protocol transparent at data rates up to 120 kbps Data arriving at the Master Port is continually broadcast to all Subchannels The user is presented with two modes of operati
2. CCITT Circuit Circuit Signal To DTE To DCE No Name Description 1 Shield 2 103 BA Send Data X 3 104 BB Receive Data X 4 105 CA Request to Send X 5 106 CB Clear to Send X 6 107 CC DCE Ready X 7 102 AB Signal Ground 8 109 CF Receive Line X Detector 15 114 DB Send Timing X 17 115 DD Receive Timing X 20 108 2 CD Terminal Ready X 22 125 CE Ring Indication X 24 113 DA External Timing X 724 746 5500 blackbox com Page 19 Black Box Tech Support FREE Live 24 7 Tech support the way it should be Great tech support is just 60 seconds away at 724 746 5500 or blackbox com lt BLACK BOX About Black Box Black Box provides an extensive range of networking and infrastructure products You ll find everything from cabinets and racks and power and surge protection products to media converters and Ethernet switches all supported by free live 24 7 tech support available in 60 seconds or less Copyright 2014 Black Box Corporation All rights reserved Black Box and the Double Diamond logo are registered trademarks of BB Technologies Inc Any third party trademarks appearing in this manual are acknowledged to be the property of their respective owners TL704A version 1 724 746 5500 blackbox com
3. MSD select either mode via a DIP Switch located inside the housing 3 5 1 Subchannel Scanning Mode The Scanning Mode allows equal access to the communications link for all connected DTE devices The Subchannels are scanned in sequence 1 2 3 4 and the attached subchannel DTE that raises RTS will access the communications link After dropping RTS the MSD will continue scanning in sequential order 724 746 5500 blackbox com Page 11 Chapter 3 Basic Operation 3 5 2 Subchannel Priority Mode The Priority Mode allows the user to have channel 1 as the highest priority channel to service the communications link The Subchannels are continually monitored If channel 2 or 3 raises RTS and transmits data and then drops RTS subchannel 1 will have the highest priority over the next port that raises RTS if subchannel 1 has information to transmit This will allow a DTE that has more important information to send or retrieve from the host a higher priority than the remaining attached terminals 3 5 3 Subchannel RTS to CTS Delay RTS to CTS delay differences are very very small for either Scanning or Priority modes of operation The Scanning Mode RTS to CTS delay times are 4 75 to 8 45 microseconds ms The Priority Mode RTS to CTS delay times are 4 75 to 5 30 microseconds ms 3 6 Anti Streaming 3 6 1 Automatic DTE Removal The MSD incorporates circuitry that will when enabled automatically remove a streaming terminal from servi
4. Panel Indicators and Switches A Green LED illuminates when AC Power has been applied Two adjacent Green LEDs illuminate in union with individual Green subchannel port activity LEDs and identify Transmit and Receive data transmissions Yellow LEDs provide a visual indication of a streaming DTE Positive latching switches for each DTE port isolate or remove a streaming terminal Each DTE port has its own switch and operates independently To disable a subchannel simply push the switch A channel is disabled when the switch is in the outermost position 3 2 Rear Panel Connectors and Fuses Located on the back of the product is an IEC Power receptacle The supplied power cord plugs into this receptacle This receptacle also contains a fuse drawer Two 2 fuses are located in this compartment For 110 VAC 10 operation the unit is equipped with slow blow 160 ma fuses For 220 VAC 10 operation the unit is equipped with slow blow 80 ma fuses The Master and Subchannel female DB25 connector are also on the back panel 3 3 Clocking The MSD derives its clocking from the attached Modem or DCE 3 4 Electrical Interface The MSD is EIA RS 232 CCITT V 24 compliant and uses female DB25 connectors Refer to the interface chart in the Appendix for detailed interface information 3 5 Subchannel Service Modes The MSD incorporates circuitry that enables the user to provide two separate modes of DTE subchannel access servicing When you install the
5. com Page 17 Chapter 4 Installation 4 6 6 Frame to Signal Ground SW 6 DIP switch position SW 6 provides the following functions ON or up EIA Pin 1 Frame Ground Connected to Pin 7 Signal Ground OFF or down EIA Pin 1 Frame Ground Not Connected Pin 7 Signal Ground 4 6 7 OR Mode and Other Options To set the TL704A to operate in OR mode set JP5 and JP6 as shown below Move the jumper located on the printed circuit card Table 4 2 Jumper settings Jumper Position Description JP5 1 2 Normal mode for RTS CTS and DTR operation 2 3 OR mode System doesn t care about RTS or DTR Any port with data gets through JP6 1 2 Normal anti stream 2 3 OR mode Anti stream is disabled Must be set when JP5 is set to OR mode JP7 1 2 Normal RTS to master port Any port RTS gives RTS to master 2 3 RTS to master is forced on JP8 JP9 1 2 CTS to user port follows RTS from that user port That JP10 JP11 port had to be active 2 3 CTS to user port is forced on 2 4 CTS to user port follows RTS from user port Port does not have to be selected JP12 1 2 DTR to master is turned on if any DTR from user ports is turned on 2 3 DTR master is forced on Page 18 724 746 5500 blackbox com Appendix EIA Interface Appendix EIA Interface Table A 1 EIA interface chart DB25 connector Pin No
6. CC and IC RFI Statements NOM Statement FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates uses and can radiate radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la classe A prescrites dans le Reglement sur le brouillage radio lectrique publi par Industrie Canada Normas Oficiales Mexicanas NO
7. DTR jumper diagram Page 14 724 746 5500 blackbox com Chapter 4 Installation 4 Installation 4 1 Voltage Selection CAUTION Check that the unit is set to the correct voltage for your application before applying AC power Located on the rear of the unit is a rotary 110 220 VAC switch Using a coin or small screwdriver gently turn the switch to the appropriate power position as required for your installation 110 or 220 VAC 4 2 Voltage Selection Fuses Located on the back or rear of the product is an IEC Power receptacle This receptacle contains a fuse drawer Two fuses are located in this compartment For 110 VAC 10 operation the unit is equipped with slow blow 5 x 20 mm 160 mA fuses For 220 VAC 10 operation the unit is equipped with slow blow 5 x 20 mm 80 mA fuses 4 3 Power Connection Before connecting the MSD to an AC power source install the top cover using the supplied 4 40 screws AC power is supplied to the MSD through a 6 6 foot 2 3 m cord terminated by a grounded 3 prong plug Select an appropriate location accessible to and within four to five feet of an AC outlet CAUTION The AC Power source MUST be grounded or the MSD warranty will be void 110 220 VAC switch Fuse drawer IEC power connector Figure 4 1 Power connection 724 746 5500 blackbox com Page 15 Chapter 4 Installation 4 4 Default Configuration Switch Settings The MSD is configured prior to shipping with th
8. M Electrical Safety Statement INSTRUCCIONES DE SEGURIDAD Todas las instrucciones de seguridad y operaci n deber n ser le das antes de que el aparato el ctrico sea operado 2 Las instrucciones de seguridad y operaci n deber n ser guardadas para referencia futura 3 Todas las advertencias en el aparato el ctrico y en sus instrucciones de operaci n deben ser respetadas 4 Todas las instrucciones de operaci n y uso deben ser seguidas 724 746 5500 blackbox com Page 3 NOM Statement 5 10 14 12 13 14 15 16 El aparato el ctrico no deber ser usado cerca del agua por ejemplo cerca de la tina de ba o lavabo s tano mojado o cerca de una alberca etc El aparato el ctrico debe ser usado nicamente con carritos o pedestales que sean recomendados por el fabricante El aparato el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante Servicio El usuario no debe intentar dar servicio al equipo el ctrico m s all lo descrito en las instrucciones de operaci n Todo otro servicio deber ser referido a personal de servicio calificado El aparato el ctrico debe ser situado de tal manera que su posici n no interfiera su uso La colocaci n del aparato el ctrico sobre una cama sof alfombra o superficie similar puede bloquea la ventilaci n no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orific
9. TL704A lt gt BLACK BOX DUE BLACK BOX FOR CONTINUED PROTE OF FINE Customer Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 Support FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax Information 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com Trademarks Used in this Manual Safety Warning Disclaimer Trademarks Used in this Manual Black Box and the Double Diamond logo are registered trademarks of BB Technologies Inc UL is a registered trademark of Underwriters Laboratories Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners SAFETY WARNING Always observe standard safety precautions during installation operation and maintenance of this product To avoid the possibility of electrical shock be sure to disconnect the power cord from the power source before you remove the IEC power fuses or perform any repairs DISCLAIMER Black Box Network Services shall not be liable for damages of any kind including but not limited to punitive consequential or cost of cover damages resulting from any errors in the product information or specifications set forth in this document and Black Box Network Services may revise this document at any time without notice Page 2 724 746 5500 blackbox com F
10. arato parece no operar normalmente o muestra un cambio en su desempe o o El aparato ha sido tirado o su cubierta ha sido da ada 724 746 5500 blackbox com Page 5 Table of Contents Table of Contents Ii SPEEMICA ONS tr deis 7 Ze SOVEIVICW ac 8 2 1 njugolo Uta N Oea e 8 22 Th ry or Operation 9 2 3 Whats Included ida 9 24 Hardware DescriptiON sssrinin 10 3 BAsSICOPEatON mirad lle 11 3 1 Front Panel Indicators and Switches 11 3 2 Rear Panel Connectors and FUSES 0 ccceseeeeeseeseeeeeeeeeeeeeeees 11 33 COKIN sacra 11 BA Electrical Interaction dida 11 3 5 Subchannel Service Modes ccecccccecceeeeeeeeeceseeseeeeeeeeeneeaes 11 3 5 1 Subchannel Scanning Mode ccceeceeteeteeetee 11 3 5 2 Subchannel Priority Mode ccecceteteteeteeeeee 12 3 5 3 Subchannel RTS to CTS Delay cece 12 36 AN ti Sth amin Qiseeessicevevscdne8 ori oasis 12 3 6 1 Automatic DTE Removal 0 0 ccc ceeeeeceeeeeeeeeeeee 12 3 6 2 Manual DTE RemoVal ooooocnncciociconiocccocccononononononnnonnos 12 3 6 3 Unexplained Streaming Terminals ooooinnnninnnn 13 37 Dial Modem SUPpOertiiaciooicaa blandos 13 3 8 Cascading or ConcatenatiOn ksenia aia entea 13 As Installation 15 4 1 Voltage Select musicians lid 15 42 Voltage Selection FUSES eccecceceeseesceceeeeeeeeeseeseeseeeeeeeeeeens 15 43 Power CONMECH OM eerten AAE 15 4 4 Default Configuration Switch Se
11. ce A streaming terminal is defined as a terminal that has RTS high longer than the user predefined anti stream timer has been set Upon installation the user can set or actually fine tune the timer to your network requirements Each channel has a green and a yellow LED to indicate subchannel activity Green indicates an active subchannel and Yellow indicates a streaming subchannel Once a terminal has gone into the streaming condition RTS continually high the DTE will automatically be removed from service until the DTE fault has been corrected by the user All other DTEs will continue to be serviced by the MSD 3 6 2 Manual DTE Removal The MSD incorporates circuitry that will when enabled manually remove a streaming terminal from service A streaming terminal is defined as a terminal that has RTS continually high With anti streaming disabled the associated streaming DTE will NOT illuminate a yellow LED on the front of the MSD If the automatic anti streaming circuitry is disabled and a streaming condition occurs the other DTE devices will be blocked from accessing the communications link To correct this condition simply push the associated push button switch for the subchannel that is streaming All other DTEs will now continue to be serviced by the MSD However you still need to fix the offending DTE that has RTS continually raised Page 12 724 746 5500 blackbox com Chapter 3 Basic Operation 3 6 3 Unexplained Streaming Termina
12. der associated with each subchannel port To use the MSD in a dial environment you must enable the jumper option on each subchannel port Dial modems must have DTR present Additionally DTR may or may not be required when cascading with other competing manufacturers modem sharing devices 4 6 3 OR Mode Jumper Options The MSD has an OR mode of operation This allows DTE devices to access the master port without RTS CTS handshaking When set to OR mode any DTE subchannel device data lead that transitions from MARK to HOLD will be given access to the Master Port All subchannel data leads are OR ed together System software must only allow one DTE device to access the Master Port at a time or the data will be garbled 4 6 4 Anti Streaming SW1 4 DIP switches SW1 4 set anti streaming as shown in the chart below To disable anti streaming set DIP switches SW1 4 all to the down position off Table 4 1 Anti streaming timeout DIP switch settings Time seconds Down Down Down Down Disabled 4 6 5 Channel Service Modes SW 5 DIP switch position SW 5 provides the subchannel service modes of operation The ON or up position provides sequential scanning of the channels This mode provides all users with equal access The DOWN or off position provides the priority mode with subchannel 1 having the highest priority over all other attached subchannels 724 746 5500 blackbox
13. e DIP Switches set as follows 1 Anti Streaming Disabled 2 Scanning Priority Priority Mode 3 Frame Signal Ground Not Connected 4 DTR Option Not Connected Figure 4 2 DIP switches on the TL704A If your system application requires one or more of the default settings to be changed you will need to remove the top cover of the MSD Remove the AC power source or disconnect the AC power before servicing the unit To remove the top cover use a small Philips screwdriver and remove the four outside screws After setting the switches replace the top cover before applying AC power 4 5 Modem DCE and Terminal DTE Connection Before applying AC Power to the unit connect the DCE and DTE cabling Use straight through male to male DB25 shielded cables no longer than 50 feet in any direction If your cables are not shielded or are over 50 feet long transmission errors are very likely 4 6 Internal Switch Settings 4 6 1 DIP Switches The MSD has an internal DIP Switch that you can access by removing the top cover Located safely inside the unit you will find a 6 position DIP switch To change the settings you may use your fingertip or a small nonconductive instrument CAUTION DO NOT use metal objects to push on the DIP switches because you may slip and damage a component trace Page 16 724 746 5500 blackbox com Chapter 4 Installation 4 6 2 DTR Jumper Option The MSD has an internal Jumper Option 3 position stick hea
14. ios de ventilaci n El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluyendo amplificadores que producen calor El aparato el ctrico deber ser connectado a una fuente de poder s lo del tipo descrito en el instructivo de operaci n o como se indique en el aparato Precauci n debe ser tomada de tal manera que la tierra fisica y la polarizaci n del equipo no sea eliminada Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos poniendo particular atenci n a los contactos y recept culos donde salen del aparato El equipo el ctrico debe ser limpiado nicamente de acuerdo a las recomendaciones del fabricante En caso de existir una antena externa deber ser localizada lejos de las lineas de energia El cable de corriente deber ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo Page 4 724 746 5500 blackbox com 17 18 NOM Statement Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilaci n Servicio por personal calificado deber ser provisto cuando El cable de poder o el contacto ha sido da ado u Objectos han ca do o l quido ha sido derramado dentro del aparato o El aparato ha sido expuesto a la lluvia o El ap
15. ls Many different types of terminals have been manufactured over the years A typical problem is unexplained lockup or lockout problems The most common cause is when four terminals are running just fine and when one of the terminals is powered down the remaining terminals are locked out of service This may be explained by a missing or incorrect Termination Resistor that has been overlooked by your terminal manufacturer This is the main reason that Anti Streaming circuitry has been designed into the MSD and we encourage the user to take advantage of this feature 3 7 Dial Modem Support The MSD supports dial modem applications by connecting the DTR jumper pin for each DTE port The jumper pin enables or disables the DTR signal to each DTE subchannel If a dial modem is used with terminals all DTR jumpers must be installed or enabled 3 8 Cascading or Concatenation The MSD supports cascading and the user simply needs to use DB25 male to male straight through shielded cables The DTR jumper pin may or may not be required for your network Older competing MSD models typically do not support the DTR pin so the jumper should be disabled in this case Use Subchannel Port 1 as the concatenation port CONNECT TO MASTER PORT DB 25 CABLE CONNECT TO PORT 1 Figure 3 1 Cascading diagram 724 746 5500 blackbox com Page 13 Chapter 3 Basic Operation JP1 E DTR connected JP2 El DTR disconnected Figure 3 2
16. on for terminal access In the first mode the attached terminal device s raises the RTS control signal and is automatically given control of the MSD until data transmission is complete In the second mode the attached terminal device s transitions data from Mark to Hold and is automatically given control of the MSD until data transmission is complete This is commonly called the OR mode of operation The attached modem provides clocking The MSD incorporates optional Anti Streaming circuitry If enabled Anti Streaming will automatically remove a defective terminal from service if the Data Control criteria is present for the user predefined clock selection period Housed in a sturdy metal enclosure and equipped with a 110 220 VAC switch selectable linear power supply the MSD will provide more than 100 000 hours of reliable service Page 8 724 746 5500 blackbox com Chapter 2 Overview J termina Host Terminal RS 232 man WA Terminal Leased ine S Modem Terminal RS 232 RS 232 Modem Sharing Device TL704A or TL708A Figure 2 1 Typical application 2 2 Theory of Operation In a polled or contention environment the typical MSD operation is as follows Data arriving at the MSD s master port is continually broadcast to all of the MSD s subchannel ports When one of the DTE devices answers the poll from the host site that DTE device will raise RTS Request To Send When RTS is raised the MSD s scanne
17. r will stop and lock onto that port and allow that DTE device to talk to the modem link The MSD will remain locked onto that port until RTS is dropped and CTS Clear To Send is dropped from the modem After RTS and CTS have dropped the MSD will automatically begin scanning the ports until another port raises RTS OPTIONALLY You may select the OR mode of operation and the contention mode will be any DTE device The DATA lead transitions from Mark to Hold will have access to the Master Port system software must only allow one device at a time 2 3 What s Included e RS 232 Modem Sharing Device 4 Port or 8 Port e 1 U S power cord e This user s manual 724 746 5500 blackbox com Page 9 Chapter 2 Overview 2 4 Hardware Description 4 5 6 7 BLACK BOX Figure 2 2 TL704A front and back panels Table 2 1 TL704A and TL708A components Number Component Description 1 4 or 8 DB25 F connectors Subchannel ports 2 1 DB25 F Master port 3 1 IEC power inlet Links to power 4 3 LEDs 1 Power 1 SD Shows unit power state and send 1 RD data and receive data on master port 5 4 or 8 Active LEDs Shows activity on subscriber ports 6 4 or 8 Stream LEDs Shows streaming on subscriber ports 7 4 or 8 Enable Disable Used to enable disable subscriber buttons ports Page 10 724 746 5500 blackbox com Chapter 3 Basic Operation 3 Basic Operation 3 1 Front
18. ttings 0c cece 16 4 5 Modem DCE and Terminal DTE Connection 16 4 6 Internal Switch Settings sionou 16 4 6 1 DIP SWITCHES anios ida 16 4 6 2 DTR Jumper OPTION cacaos 17 4 6 3 OR Mode Jumper Options ooccccioncncnicnicicciins 17 4 6 4 Anti Streaming SW 1 4 oocoocncncccnoononnonoonnonnnnnonncnnonnn 17 4 6 5 Channel Service Modes SW 5 n 17 4 6 6 Frame to Signal Ground SW B ooononconiccicnnnncocinnin 18 4 6 7 OR Mode and Other OptiONS ooonoicicninnnnncic 18 Appendix EIA Interface Chart ccccccccccceceseeccesccteseeseeeeeceesaeseeneceeataeeaeeatas 19 Page 6 724 746 5500 blackbox com 1 Specifications Anti Streaming Chapter 1 Specifications Automatic Selectable timeout intervals Disable Selectable via DIP switch Application Works with up to 4 sync async terminal or DTE devices operating in a polled environment to share one modem Approvals Safety UL 1950 CSA C22 2 Capacity 4 or 8 RS 232 sync async devices Data Format Data transparent at all data rates Data Rate Up to 120 kbps Flow Control Handshaking RTS CTS Optional OR mode Terminal Rotational sequence for equal access Service Modes Timing External from the attached modem User Controls For each subchannel 1 Enable disable switch Interface EIA RS 232 CCITT V 24 using DB25 female connectors Connectors TL704A 4 DB25 F 1 DB25 F master port TL708A 8 DB25 F
Download Pdf Manuals
Related Search
Related Contents
wivia Docs取扱説明書(T04900100014B) Manuel de WinDisp 4.0 - Food and Agriculture Organization of the User Guide for Cisco Virtualization Experience Client 6215 取扱説明書はこちら - e Heavy-Duty Installation User Manual Manual - Amico MANUEL D`UTILISATION CoPool - Fraunhofer-Institut für Techno Copyright © All rights reserved.