Home

Postage USA (Model C)

image

Contents

1. is Selftest You will need the serial number of your scale when ordering new chip upgrade
2. Federal Trade Commission Improvements Act Public Law 93 637 1975 is available under this warranty Although it is not mandatory to avoid unnecessary difficulties in determining your eligibility for warranty work we suggest you fill out your warranty Registration Card and mail it to the address listed on the card within ten 10 days after purchase of your Scale E L A N E USER S MANUAL Postage USA Model C Electronic Postage Computing Scale BASIC CLASSES AVAILABLE First Class Letters Stamps Flats Packages Priority Class 1 P Packages PK First Class Mail International Letters Flats Packages IL IF IP Express Mail E Media Mail MED ff o o SPECIAL FEATURES First Class International Letters Flats Packages Groups 1 to 9 Priority Mail Zones 1 9 P1 P9 Packages Zones 0 9 PK0 PK9 Express Mail Zones 1 to 9 and Media Mail Tare Upon Turn On No limit except overload Domed Keyboard for Tactile Response Strain Gauge Loadcell Technology Easily Replaceable Plug in Rate Change Chip User Calibration of 5lbs WONOAPWONs BASIC TECHNICAL DETAILS Maximum Capacity 5 Ibs Including Tare Accuracy 0 1 oz Power Supply 9 volt AC adapter UL rated Power Consumption Approx 400mW Minimum add Weight 0 1 oz Minimum Weight 0 2 oz Dimensions W eight Overall 734 x 51 2 x 21 4 Platform 5 x 5 opens for flats Unit Weight 1 Ib 2 8 oz Packaged Weight 2
3. LIMITED WARRANTY Postage USA PARTS AND LABOR 6 MONTHS Elane warrants your Scale to be free from factory defects in material and workmanship for parts and labor from the date of original purchase The obligation under this warranty is limited to repairing or replacing any defective part and providing all necessary labor for 6 months in connection with the correction of any defect If a Scale fails within the first 30 days from the date of purchase Elane will replace the defective Scale if it is returned freight prepaid by the owner to Elane s Representative named below After 30 days Elane will at its option repair or replace a defective Scale so returned by an owner Return freight will be prepaid unless a unit is to be returned to any address outside of the United States then shipping charges must be paid in advance by the owner ALL WARRANTY REPAIRS MUST BE ACCOMPANIED BY PROOF OF PURCHASE The exchange of any factory defective Scale is at the exclusive option of Elane and in no event does Elane assume liability for any damage beyond the refund of the purchase price or the replacement or repair of the Scale Any usage of a Scale for purposes other than those intended by its inherent nature and any usage in connection with electrical systems other than those for which the unit was designed will VOID this warranty All implied warranties to a Scale except to the extent prohibited by applicable law shall have no greater duration than the wa
4. il Zone 9 pressing this key again will display rates for Media Mail MED Ib 0z C SPECIAL FEATURES a Tare Feature Press the ON OFF ZERO key with the item to be tared on the platform and the display will go to 0 00z To clear tare remove the weight the display will read a negative number Press ON OFF ZERO again and the display will go to 0 00z b Open the platform to mail flats and large envelopes to avoid covering the keyboard and display CAUTION The platform is designed to open ONLY 70 degrees angle so that the piece being weighed is centered over the load cell DO NOT FORCE D USER CALIBRATION When the scale loses its accuracy user calibration can be performed Make sure that you have a 5 lb weight to use Turn on scale and press Packages key while display is Selftest to enter user calibration The scale will prompt you to put 5 Ib weight on the platform Put exact 5 lb weight on the platform and the scale will automatically calibrate itself if correct weight is put After which the scale will prompt you to remove the weights and then restart your scale E SPECIAL NOTES a The Scale will display Overload if any weight over 5 lbs 0 4 oz is placed on the platform b The Scale will display ExcessWt when the current weight exceeds the maximum allowed for the selected service c To display the serial number of the scale press i Class Priority Mail key during scale startup or while display
5. lbs 4 oz A i 2 3 START UP INSTRUCTIONS Place the Scale on a flat surface Plug AC adapter included into Postage USA port at back of unit and then into standard electrical outlets Press ON OFF ZERO to turn Scale on The display will read Selftest The Scale will then go through an electronic self test for 1 3 seconds If the Scale is not stable the display will not change If excess TARE or other LOAD is being applied the display will read Overload until the excess weight is removed When the Scale has passed it s self test and is ready for weighing the display will read 1L 0 00 0 0 oz The Scale is now ready for weighing and calculating postage rates NOTE Open the platform prior to turning on the Scale if mailing larger flat items DO NOT FORCE TO OPEN PAST ITS DESIGNED ANGLE OF APPROX 70 DEGREES B POSTAL SELECTIONS 1 2 First Class Priority The Scale automatically sets up to weigh 1st Class Letters after going through its self test The display will read 1L 0 0 0lb0 0 oz The Scale will switch to 1 Class Large Envelopes Flats rates when weight exceeds 3 5 oz The display will read 1F 0 0 0lb0 0 oz When in 1 Class Letters pressing 1 Class Priority Mail key will display the rates of 1 Class Large Envelopes Pressing this key again will display the rates of 1 Class Packages Parcels The display will read P 0 0 0lb0 0 oz When the item on the platform exceeds 13 oz it will aut
6. omatically switch to Priority Mail service as required by USPS REGULATIONS You may weigh pieces up to 5 lbs TARE with automatic calculation and display of the postage due NOTE RATES FOR PRIORITY MAIL MAY VARY DEPENDING UPON THE ZONE OF DESTINATION a Example of Zone selection You are mailing an item that is over 13 oz so the Scale automatically displays Set Zone To select the zone of destination continue pressing the 1 Class Priority Mail key until the proper zone is shown e g Zone 1 P1 and so on or press the key assigned to a priority service zone e g Zone 5 will display P5 Priority Zone 8 key toggles with Zone 8 and Zone 9 new as at January 26 2014 The Scale will automatically calculate and display the postage due To change zones simply press the 1 Class Priority Mail key again and then choose desired zone Packages Parcel Post a To mail pieces at these rates simply press the Packages key The display will then read PKO 0 00 0lb 0 0 oz where PK is displayed as special character b You may now weigh pieces up to 5 lbs with automatic calculation and display of the postage due c Continue pressing Packages key to show the rates for other zones e g 1 to 9 NOTE PACKAGES RATES MAY VARY DEPENDING UPON THE ZONE OF DESTINATION Zone 0 displays the rate for single piece bound to a Local zone Zone 1 to Zone 9 displays the rate for a single piece bound to zones 1 to 9 3 First Cla
7. rranty period set forth herein No warranties whether expressed or implied including warranties of merchantability or fitness shall apply to a Scale after the warranty period has expired Elane shall not be liable for liabilities or obligations for damages including but not limited to special indirect or consequential damages or loss of use revenue or profits in connection with or arising out of any failure or defect in a Scale Some states do not allow limitation on how long an implied warranty last and exclusions or limitations of incidental or consequential damages so the above limitation or exclusions may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from state to state This warranty extends only to the original purchaser and is not assignable or transferable This warranty shall not apply to any Scale which has been improperly maintained or repaired including the installation of parts or accessories that do not conform to the quality and specifications of the original components or parts or that may have been subject to alterations abuse misuse neglect including improper installation accidental or intentional damage or to any product which may have had serial numbers or model numbers altered defaced or removed Any modification or repair by unauthorized parties will VOID this warranty No informal dispute settlement mechanism as allowed under The Magnuson Moss Warranties
8. ss Mail Int l Letters Flats Large Envelopes Parcels a First press of 1 Class Mail Int key coming from other service will display rates for 1 Class Mail Int l Letters Price Group 1 Canada ILC Ib oz where IL is displayed as a special character Press again to display the rates for 1 Class Mail Int l Letters Price Group 2 Mexico ILM Ib oz where IL is displayed as a special character Successive presses of 17 Class Mail Int l key will display rates for Letters for other Price Groups 3 to 9 b Press Letters Flats Packages key to switch between rates for Letters Flats Large Envelopes and Packages Small Packets of the selected price group Sample displays are ILC Ib oz where IL is displayed as special character 1 Class Mail International Letters to Canada IFC lb oz where IF is displayed as special character 1 Class Mail International Flats Large Envelopes to Canada IPC Ib oz where IP is displayed as special character 1 Class Mail International Packages Small Packets to Canada c When current service is 1 Class Mail International Letters and weight exceeds 3 5 oz it will automatically switch to 1 Class Mail International Flats 4 Express Mail Media Mail a First press displays the rates for Express Mail Zone 1 E1 lb oz Successive presses will display rates for other zones 2 to 9 When already in Express Ma