Home

JY997D22901F GT10 General Description

image

Contents

1. RS 422 1ch 115 200 57 600 38 400 19 200 9 600 4 800bps Item GT1020 LBD2 LBDW2 Communication standard RS 232 ich PLC communication Transmission speed Connector shape Connector terminal block 9 pins RS 232 1ch 115 200 57 600 38 400 19 200 9 600 4 800bps MINI DIN 6 pins Female Communication standard PC communication 1 Transmission speed Connector shape 1 Project data upload download OS installation Transparent function 1 4 Power Supply Specifications For details on power supply wiring such as the allowable cable size and tightening torque refer to the additional manual GT10 User s Manual Specifications Item GT1020 LBD LBD2 LBDW LBDW2 GT1020 LBL LBLW 24VDC 10 15 ripple voltage 200mV or less 5VDC 5 supplied from the PLC 1 9W 80mA 24VDC or less 1 2W 50mA 24VDC or less 1 1W 220mA 5VDC or less 0 6W 120mA 5VDC or less Inrush current 13A or less 26 4VDC ims al ais instantaneous power failure Within 5ms E Noise immunity Noise voltage 1000Vp p Noise width 1us by noise simulator of 30 to 100Hz noise frequency Input power supply voltage Fuse built in not exchangeable Power consumption At backlight off Dielectric withstand voltage 2 500VAC for 1 minute between the GOT s power supply terminals and the GOT s grounding terminal Insulation resistance 2 10MQ or larger by insulation resistance tester between the GOT s power supply terminals and the GOT s grounding
2. 91 x D27 1 06 mm inch Excluding mounting fixtures Horizontal format W105 4 13 x H66 2 59 mm inch Horizontal format Flash memory ROM Internal for storing Project data 512kbytes or less OS Alarm history and Recipe data Weight Excluding mounting fixtures 0 2kg 0 18kg 0 2kg 0 18kg Compatible software package GT Designer2 Version2 43V or later GT Designer2 Version2 58L or later 1 Bright dots always lit and dark dots unlit may appear on a liquid crystal display panel It is impossible to completely avoid this symptom as the liquid crystal display comprises of a great number of display elements Flickers may be observed depending on the display color Please note that these dots appear due to its characteristic and are not caused by product defect When the same screen is displayed for a long time an incidental color or partial discoloration is generated on the screen due to heat damage and it may not disappear To prevent heat damage the screen saver function is effective For details on the screen saver function refer to the following lt 3 GT10 User s Manual 1 3 Communication Specifications 2 For the details of system information refer to the following lt L 3 GT Designer2 VersionO Screen Designer Manual 3 ROM in which new data can be written without deleting the written data 4 Note that this does not guarantee all users operation environment Specifications GT1020 LBD LBL LBDW LBLW
3. mounting and terminal screws in the specified torque range Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit TEST OPERATION PRECAUTIONS DANGER e Before performing the test operations of the user creation monitor screen such as turning ON or OFF bit device changing the word device current value changing the settings or current values of the timer or counter read through the manual carefully and make yourself familiar with the operation method During test operation never change the data of the devices which are used to perform significant operation for the system False output or malfunction can cause an accident STARTUP MAINTENANCE PRECAUTIONS DANGER e When power is on do not touch the terminals Doing so can cause an electric shock or malfunction e Before starting cleaning or terminal screw retightening always switch off the power externally in all phases Not switching the power off in all phases can cause a unit failure or malfunction Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit STARTUP MAINTENANCE PRECAUTIONS CAUTION e Do not disassemble or modify the unit Doing so can cause a failure malfunction injury or fire e Do not touch the conductive and electronic
4. parts of the unit directly Doing so can cause a unit malfunction or failure e The cables connected to the unit must be run in ducts or clamped Not doing so can cause the unit or cable to be damaged due to the dangling motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault e When unplugging the cable connected to the unit do not hold and pull the cable portion Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault e Before touching the unit always touch grounded metal etc to discharge static electricity from human body etc Not doing so can cause the unit to fail malfunction TRANSPORTATION PRECAUTIONS CAUTION e When disposing of the product handle it as industrial waste e Make sure to transport the GOT main unit and or relevant unit s in the manner DISPOSAL PRECAUTIONS CAUTION ee tee erie they will not be exposed to the impact exceeding the impact resistance described in the general specifications of this manual as they are precision devices Failure to do so may cause the unit to fail Check if the unit operates correctly after transportation Compliance with EC directive CE Marking This note does not guarantee that an entire mechanical module produced in accordance with the contents of this note will comply with the following standards Compliance to EMC directive for the entire mechanical module sho
5. terminal Grounding 2 Class D grounding 100 or less To be connected to the panel when grounding is not possible The GOT continues to operate even upon 5ms or shorter instantaneous power failure The GOT stops operating if there is extended power failure or voltage drop while it automatically resumes operation as soon as the power is restored 2 This cable cannot be used for GT1020 LBL and GT1020 LBLW 2 Wiring of connection cable The diagram below shows cable assignment for GOT port Cables GT10 COOOR4 8P GT10 COOOR4 2P GT10 COOOR2 6P PLC connection cable GOT This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual GT10 COOOR4 25P GT10 CO OOR2 6P Warranty OT G Mitsubishi will not be held liable for damage caused by factors found not to be G terminal the cause of Mitsubishi opportunity loss or lost profits caused by faults in the block Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactu
6. while the input of the touch switch s remains active This may confuse an operator in thinking that the GOT is in screensaver mode who then tries to release the GOT from this mode by touching the display section which may cause a touch switch to operate DESIGN PRECAUTIONS Z CAUTION e Do not bundle the control and communication cables with main circuit power or other wiring Run the above cables separately from such wiring and keep them a minimum of 100mm 3 94in apart Not doing so noise can cause a malfunction MOUNTING PRECAUTIONS lt SDANGER MOUNTING PRECAUTIONS CAUTION WIRING PRECAUTIONS WIRING PRECAUTIONS CAUTION TEST OPERATION PRECAUTIONS STARTUP MAINTENANCE PRECAUTIONS STARTUP MAINTENANCE PRECAUTIONS Be sure to shut off all phases of the external power supply used by the system before mounting or removing the GOT to from the panel Not doing so can cause the unit to fail or malfunction Use the GOT in the environment that satisfies the general specifications described in this manual Not doing so can cause an electric shock fire malfunction or product damage or deterioration When mounting the GOT to the control panel tighten the mounting screws in the specified torque range Undertightening can cause the GOT to drop short circuit or malfunction Overtightening can cause a drop short circuit or malfunction due to the damage of the screws or the GOT DANGER Be sure to shut off all phases o
7. Melsec FX series PLC GT1020 LBD2 GT1020 LBDW2 GT10 C30R2 6P For Melsec Q series PLC 2 General notes on the use of the power cable The GT1020 LBD LBD2 LBDW LBDW2 unit demand that the cable for the power supply is 10m or less Associated Manuals The following manuals are relevant to this product When these loose manuals are required please consult with our local distributor Manual Number Contents Model Code Manual name GT10 User s Manual sold separately JY997D24701 09R819 Describes the GT10 hardware relevant content such as part names external dimensions mounting power supply wiring specifications and introduction to option devices GOT1000 Series Connection Manual 1 3 2 3 3 3 sold separately 1 SH 080532ENG 1D7M26 Describes system configurations of the connection method applicable to GOT1000 series and cable creation method GT Designer2 Version2 Basic Operation Data Transfer Manual For GOT1000 Series sold separately 1 SH 080529ENG 1D7M24 Describes methods of the GT Designer2 installation operation basic operation for drawing and transmitting data to GOT1000 series SH 080530ENG SH 080531ENG 1D7M25 GT Designer2 Version2 Screen Design Manual For GOT1000 Series 1 3 2 3 3 3 sold separately 1 Describes specifications and settings of the object functions used in GT Designer2 Stored in the GT Works 2 GT Designer2 in PDF format For details of a PLC to be
8. Not doing so can cause an accident due to false output or malfunction Do not use the GOT as the warning device that may cause a serious accident An independent and redundant hardware or mechanical interlock is required to configure the device that displays and outputs serious warning Failure to observe this instruction may result in an accident due to incorrect output or malfunction Incorrect operation of the touch switch s may lead to a serious accident if the GOT backlight is gone out When the GOT backlight goes out causes the monitor screen to appear blank while the input of the touch switch s remains active This may confuse an operator in thinking that the GOT is in screensaver mode who then tries to release the GOT from this mode by touching the display section which may cause a touch switch to operate DESIGN PRECAUTIONS CAUTION e Do not bundle the control and communication cables with main circuit power or other wiring Run the above cables separately from such wiring and keep them a minimum of 100mm 3 94in apart Not doing so noise can cause a malfunction MOUNTING PRECAUTIONS DANGER e Be sure to shut off all phases of the external power supply used by the system before mounting or removing the GOT to from the panel Not doing so can cause the unit to fail or malfunction MOUNTING PRECAUTIONS CAUTION e Use the GOT in the environment that satisfies the general specifications described in this ma
9. Side JY997D22901F B EA JAPANESE S E ENGLISH a MITSUBISHI GT1020 LBDO LBD0O2 LBLO GT10 General Description EERO ETES Manual Number JY997D22901F Nooo ae This manual describes the specifications of the product Before use read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions And store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user Registration The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company Effective Sep 2008 Specifications are subject to change without notice 2008 Mitsubishi Electric Corporation Changes for the Better Safety Precaution Read these precautions before using Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this product In this manual the safety precautions are ranked as DANGER and CAUTION Indicates that incorrect handling may cause hazardous lt gt DANGER conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous CAUTION conditions resulting in medium or slight
10. T10 COOOR4 2P GT10 COOOR2 6P GOT PLC i This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be PLC connection cable held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi opportunity loss or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life GT10 CL GT10 CI GOT GOT terminal terminal block block R4 25P GT10 COI Yellow Green Black e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installi
11. colors green red orange LED with 3 available colors white red pink Backlight no replacement required Backlight status colors ON BLINK OFF control Adjustable screensaver activation time Setting the system information enables 2 PLC to control the backlight status Number of touch keys Maximum 50 keys screen Analog resistive film touch panel Key size Minimum 2 x 2 dots per key ee Simultaneous pressing of Not stipoonied two or more areas Simultaneous pressing of two or more areas on the screen may activate the switch between those areas 2 point press 1 million times or more operating force 0 98N max Flash memory ROM Internal for storing Project data 512kbytes or less OS Alarm history and Recipe data Memory ifg Number of write times 100 000 times Buzzer output a buzzer that sounds when touch Single tone LONG SHORT OFF adjustable keys are pressed Equivalent to IP67 JEM1030 front section W113 4 44 x H74 2 91 x D27 1 06 mm inch Excluding mounting fixtures Horizontal format Panel cutting dimensions W105 4 13 x H66 2 59 mm inch Horizontal format Weight Excluding mounting fixtures 0 2kg 0 18kg 0 2kg 0 18kg Compatible software package GT Designer2 Version2 43V or later GT Designer2 Version2 58L or later Environmental protective structure 4 External dimensions Bright dots always lit and dark dots unlit may appear on a liquid crystal display panel It is imp
12. connected refer to the PLC user s manual respectively Bundled Items Explanation of the GOT model name Model Name Remark GT1020 x x x GT1020 LBD L Interface type for 2 RS 232 GT1020 LBD2 communication with PLC Blank RS 422 Backlight type W white red pink GT1020 LBL GOT main unit Blank green red orange GT1020 LBDW The maintenance supplies below are packed with the product Power type D 24VDC L 5VDC OORO Eepw2 Panel color type B Black GT1020 LBLW L STN monochrome 0 Monochrome black white Display device type Display color type Maintenance Supplies Quantity Screen size type 3 4 5 a 2 3 7 PLC Communication Connector 1 GOT1000 series GT10 Panel Mounting Bracket with M4 x 20 screws 4 Panel Mounting Packing 1 GT10 General Description This manual 1 1 Specifications 1 1 General Specifications Item Operating ambient Display section 0 to 50 C temperature Storage ambient temperature 20 to 60 C Operating ambient humidity Storage ambient humidity Conforms to JIS B3502 and vibration Vibration resistance 1IEC61131 2 Shock resistance Operating atmosphere Operating altitude 2000 m 6562 ft max Installation location Inside control panel Overvoltage category 2 ll or less Pollution degree s 2 or less Cooling method Self cooling Specifications GT1020 LBD LBD2 LBL LBDW LBDW2 LBLW Other than display section 0 to 55 C When mounted horizontally 0 to 50 C When mount
13. d and tests ESD RF electromagnetic field EFTB Surge RF conducted disturbances and Power frequency magnetic field Compliance with all relevant aspects of the standard Radiated Emissions For more details please contact the local Mitsubishi Electric sales site Notes for compliance to EMC regulation 1 General notes on the use of communication cables Any device which utilizes a data communication function is susceptible to the wider effects of local EMC noise Therefore when installing any communication cables care should always be taken with the routing and location of those cables The GOT units identified on the previous chapter are compliant with the EMC requirement when the following communication cables are used GOT Unit Existing Cables GT1020 LBD GT1020 LBL GT1020 LBDW GT1020 LBLW GT10 C30R4 8P For Melsec FX series PLC GT1020 LBD2 GT1020 LBDW2 GT10 C30R2 6P For Melsec Q series PLC 2 General notes on the use of the power cable The GT1020 LBD LBD2 LBDW LBDW2 unit demand that the cable for the power supply is 10m or less Associated Manuals The following manuals are relevant to this product When these loose manuals are required please consult with our local distributor Manual Number Contents Model Code Manual name GT10 User s Manual Describes the GT10 hardware relevant content such as part names external dimensions JY997D24701 sold separately mounting power supply wiring specifications and in
14. dy etc Not doing so can cause the unit to fail malfunction TRANSPORTATION PRECAUTIONS CAUTION e When disposing of the product handle it as industrial waste Make sure to transport the GOT main unit and or relevant unit s in the manner DISPOSAL PRECAUTIONS CAUTION ea e pe a A E E they will not be exposed to the impact exceeding the impact resistance described in the general specifications of this manual as they are precision devices Failure to do so may cause the unit to fail Check if the unit operates correctly after transportation Compliance with EC directive CE Marking This note does not guarantee that an entire mechanical module produced in accordance with the contents of this note will comply with the following standards Compliance to EMC directive for the entire mechanical module should be checked by the user manufacturer For more details please contact the local Mitsubishi Electric sales site Requirement for Compliance with EMC directive The following products have shown compliance through direct testing to the identified standards and design analysis forming a technical construction file to the European Directive for Electromagnetic Compatibility 89 336 EEC when used as directed by the appropriate documentation Type Programmable Controller Open Type Equipment Standard Remark EN61131 2 2003 Programmable controllers Equipment requirement Compliance with all relevant aspects of the standar
15. ed vertically 10 to 90 RH non condensing The wet bulb temperature is 39 C or less 10 to 90 RH non condensing The wet bulb temperature is 39 C or less Sweep Count vibration Conforms to JIS B3502 IEC 61131 2 147m s2 11 ms Sine half wave pulse 3 times each in the X Y and Z directions Must be free of lamp black corrosive gas flammable gas or excessive amount of electroconductive dust particles and must be no direct sunlight Same as for saving Do not use or store the GOT under pressure higher than the atmospheric pressure of altitude Om Oft Failure to observe this instruction may cause a malfunction 2 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within the premises Category II applies to equipment for which electrical power is supplied from fixed facilities The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V 3 This index indicates the degree to which conductive material is generated in the environment where the equipment is used In pollution degree 2 only non conductive pollution occurs but temporary conductivity may be produced due to condensation 1 2 Performance Specifications Item GT1020 LBD LBD2 GT1020 LBL GT1020 LBDW LBDW2 Specifications GT1020 LBLW Left Right 30 degrees Top 20 degrees Bottom 30 degrees Horizontal for
16. f the external power supply used by the system before wiring Failure to do so may result in an electric shock product damage or malfunctions Please make sure to ground FG terminal of the GOT power supply section by applying 100 or less which is used exclusively for the GOT Not doing so may cause an electric shock or malfunction Correctly wire the GOT power supply section after confirming the rated voltage and terminal arrangement of the product Not doing so can cause a fire or failure Tighten the terminal screws of the GOT power supply section in the specified torque range Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or the GOT Exercise care to avoid foreign matter such as chips and wire offcuts entering the GOT Not doing so can cause a fire failure or malfunction Plug the communication cable into the connector of the connected unit and tighten the mounting and terminal screws in the specified torque range Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit lt SDANGER Before performing the test operations of the user creation monitor screen such as turning ON or OFF bit device changing the word device current value changing the settings or current values of the timer or counter read through the manual carefully and make
17. hese precautions before using Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this product In this manual the safety precautions are ranked as DANGER and CAUTION Indicates that incorrect handling may cause hazardous lt gt DANGER conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous conditions resulting in medium or slight personal injury or physical damage Depending on circumstances procedures indicated by CAUTION may also be linked to serious results In any case it is important to follow the directions for usage DESIGN PRECAUTIONS lt DANGER e Some failures of the GOT or cable may keep the outputs on or off An external monitoring circuit should be provided to check for output signals which may lead to a serious accident Not doing so can cause an accident due to false output or malfunction If a communication fault including cable disconnection occurs during monitoring on the GOT communication between the GOT and PLC CPU is suspended and the GOT becomes inoperative A system where the GOT is used should be configured to perform any significant operation to the system by using the switches of a device other than the GOT on the assumption that a GOT communication fault will occur
18. mat 200 cd m2 in green 300 cd m2 in white Life Approx 50 000h Time for display intensity to become 1 5 at operating ambient temperature of 25 C LED with 3 available colors white red pink STN monochrome white black liquid crystal 160 x 64 dots Horizontal format W86 4 3 4 x H34 5 1 35 mm inch Horizontal format Display 16 dot standard font 20 characters x 4 lines Horizontal format section Monochrome white black 16 level adjustment eS LED with 3 available colors green red orange Backlight no replacement required Backlight status colors ON BLINK OFF control Adjustable screensaver activation time Setting the system information enables 2 PLC to control the backlight status Number of touch keys Key size Minimum 2 x 2 dots per key Touch panel Simultaneous pressing of two or more areas Not supported 2 point press Maximum 50 keys screen Analog resistive film touch panel Simultaneous pressing of two or more areas on the screen may activate the switch between those areas Life 1 million times or more operating force 0 98N max User memory 3 Memory Life Number of write times 100 000 times Buzzer output a buzzer that sounds when touch Single tone LONG SHORT OFF adjustable keys are pressed Environmental protective structure 4 External dimensions Panel cutting dimensions Equivalent to IP67 JEM1030 front section W113 4 44 x H74 2
19. nector 1 GOT1000 series GT10 Panel Mounting Bracket with M4 x 20 screws 4 Panel Mounting Packing 1 GT10 General Description This manual 1 1 Specifications 1 1 General Specifications Specifications GT1020 LBD LBD2 LBL LBDW LBDW2 LBLW Item Operating ambient Display section 0 to 50 C iemperature Other than display section 0 to 55 C When mounted horizontally 0 to 50 C When mounted vertically Storage ambient temperature 20 to 60 C Operating ambient humidity 10 to 90 RH non condensing The wet bulb temperature is 39 C or less Storage ambient humidity 10 to 90 RH non condensing The wet bulb temperature is 39 C or less Under intermittent St09Hz 35m vibration Sto 150Hz 9 8mvs __ A times each inx Conforms to JIS B3502 IEC 61131 2 147m s2 11 ms Sine half wave pulse 3 times each in the X Y and Z directions Sweep Count Conforms to JIS Vibration resistance B3502 and 1IEC61131 2 Shock resistance Must be free of lamp black corrosive gas flammable gas or excessive amount of electroconductive dust particles and must be no direct sunlight Same as for saving 2000 m 6562 ft max Operating atmosphere Operating altitude Installation location Inside control panel Overvoltage category 2 ll or less Pollution degree s 2 or less Cooling method Self cooling 1 Do not use or store the GOT under pressure higher than the atmospheric pressure of altitude Om Oft Fail
20. ng the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system User made cable is necessary depending on the PLC For the detail refer to GOT1000 Series Connection Manual Cable jacket to remove 7mm 0 27 Tightening torque 0 22 to 0 25 Nem Aa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN HIMEJI WORKS 840 CHIYODA CHO HIMEJI JAPAN SZS 0 4 x 2 5 Phoenix Contact Inc Recommended Tool Screwdriver Side JY997D22901F B EA JAPANESE SE ENGLISH a MITSUBISHI GT1020 LBDO LBD0O2 LBLO GT10 General Description SPANAT ENPE Manual Number JY997D22901F Tiooo Sep This manual describes the specifications of the product Before use read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions And store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user Registration The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company Effective Sep 2008 Specifications are subject to change without notice 2008 Mitsubishi Electric Corporation Changes for the Better Safety Precaution Read t
21. nual Not doing so can cause an electric shock fire malfunction or product damage or deterioration e When mounting the GOT to the control panel tighten the mounting screws in the specified torque range Undertightening can cause the GOT to drop short circuit or malfunction Overtightening can cause a drop short circuit or malfunction due to the damage of the screws or the GOT WIRING PRECAUTIONS lt SDANGER e Be sure to shut off all phases of the external power supply used by the system before wiring Failure to do so may result in an electric shock product damage or malfunctions e Please make sure to ground FG terminal of the GOT power supply section by applying 100 or less which is used exclusively for the GOT Not doing so may cause an electric shock or malfunction e Correctly wire the GOT power supply section after confirming the rated voltage and terminal arrangement of the product Not doing so can cause a fire or failure e Tighten the terminal screws of the GOT power supply section in the specified torque range Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or the GOT e Exercise care to avoid foreign matter such as chips and wire offcuts entering the GOT Not doing so can cause a fire failure or malfunction WIRING PRECAUTIONS CAUTION e Plug the communication cable into the connector of the connected unit and tighten the
22. ossible to completely avoid this symptom as the liquid crystal display comprises of a great number of display elements Flickers may be observed depending on the display color Please note that these dots appear due to its characteristic and are not caused by product defect When the same screen is displayed for a long time an incidental color or partial discoloration is generated on the screen due to heat damage and it may not disappear To prevent heat damage the screen saver function is effective For details on the screen saver function refer to the following GT10 User s Manual 1 3 Communication Specifications 2 For the details of system information refer to the following L3 GT Designer2 VersionO Screen Designer Manual 3 ROM in which new data can be written without deleting the written data 4 Note that this does not guarantee all users operation environment Specifications GT1020 LBD LBL LBDW LBLW RS 422 1ch 115 200 57 600 38 400 19 200 9 600 4 800bps Item GT1020 LBD2 LBDW2 Communication standard RS 232 1ch PLC communication Transmission speed Connector shape Connector terminal block 9 pins RS 232 1ch 115 200 57 600 38 400 19 200 9 600 4 800bps MINI DIN 6 pins Female Communication standard PC communication 1 Transmission speed Connector shape Project data upload download OS installation Transparent function 1 4 Power Supply Specifications For details on power supply wiring s
23. personal injury or physical damage Depending on circumstances procedures indicated by CAUTION may also be linked to serious results In any case it is important to follow the directions for usage DESIGN PRECAUTIONS lt SDANGER e Some failures of the GOT or cable may keep the outputs on or off An external monitoring circuit should be provided to check for output signals which may lead to a serious accident Not doing so can cause an accident due to false output or malfunction If a communication fault including cable disconnection occurs during monitoring on the GOT communication between the GOT and PLC CPU is suspended and the GOT becomes inoperative A system where the GOT is used should be configured to perform any significant operation to the system by using the switches of a device other than the GOT on the assumption that a GOT communication fault will occur Not doing so can cause an accident due to false output or malfunction Do not use the GOT as the warning device that may cause a serious accident An independent and redundant hardware or mechanical interlock is required to configure the device that displays and outputs serious warning Failure to observe this instruction may result in an accident due to incorrect output or malfunction Incorrect operation of the touch switch s may lead to a serious accident if the GOT backlight is gone out When the GOT backlight goes out causes the monitor screen to appear blank
24. red to be incorporated in a device or system used in purposes related to human life GT10 cCO0O00R4 8P Red Orange Yellow Green e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric User made cable is necessary depending on the PLC For the detail refer to GOT1000 Series Connection Manual 7mm 0 27 e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system afa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN HIMEJI WORKS 840 CHIYODA CHO HIMEJI JAPAN Cable jacket to remove Tightening torque 0 22 to 0 25 Nem SZS 0 4 x 2 5 Phoenix Contact Inc Recommended Tool Screwdriver
25. troduction to option devices 09R819 GOT1000 Series Connection Manual 1 3 2 3 3 3 Describes system configurations of the connection method applicable to GOT1000 series SH 080532ENG sold separately 1 and cable creation method 1D7M26 GT Designer2 Version2 Basic Operation Data Transfer Manual For GOT1000 Series sold separately 1 SH 080529ENG 1D7M24 Describes methods of the GT Designer2 installation operation basic operation for drawing and transmitting data to GOT1000 series SH 080530ENG SH 080531ENG 1D7M25 GT Designer2 Version2 Screen Design Manual For GOT1000 Series 1 3 2 3 3 3 sold separately 1 Describes specifications and settings of the object functions used in GT Designer2 1 Stored in the GT Works 2 GT Designer2 in PDF format For details of a PLC to be connected refer to the PLC user s manual respectively Bundled Items Explanation of the GOT model name Model Name Remark GT1020 x x x x GT1020 LBD L Interface type for 2 RS 232 GT1020 LBD2 communication with PLC Blank RS 422 Backlight type W white red pink GT1020 LBL GOT main unit Blank green red orange GT1020 LBDW _ The maintenance supplies below are packed with the product Power type D 24VDC L 5VDC GT 1020 CBDW2 Panel color type B Black GT1020 LBLW Display device type L STN monochrome Display color type 0 Monochrome black white Maintenance Supplies Quantity Screen size type Be a 2 3 7 PLC Communication Con
26. uch as the allowable cable size and tightening torque refer to the additional manual GT10 User s Manual Specifications Item GT1020 LBD LBD2 LBDW LBDW2 GT1020 LBL LBLW 24VDC 10 15 ripple voltage 200mV or less 5VDC 5 supplied from the PLC 1 9W 80mA 24VDC or less 1 2W 50mA 24VDC or less 1 1W 220mA 5VDC or less 0 6W 120mA 5VDC or less Inrush current 13A or less 26 4VDC ims Poe instantaneous power failure Within 5ms E Noise immunity Noise voltage 1000Vp p Noise width 1us by noise simulator of 30 to 100Hz noise frequency Input power supply voltage Fuse built in not exchangeable Power consumption At backlight off Dielectric withstand voltage 2 500VAC for 1 minute between the GOT s power supply terminals and the GOT s grounding terminal Insulation resistance 2 10MQ or larger by insulation resistance tester between the GOT s power supply terminals and the GOT s grounding terminal Grounding 2 Class D grounding 100 or less To be connected to the panel when grounding is not possible The GOT continues to operate even upon 5ms or shorter instantaneous power failure The GOT stops operating if there is extended power failure or voltage drop while it automatically resumes operation as soon as the power is restored 2 This cable cannot be used for GT1020 LBL and GT1020 LBLW 2 Wiring of connection cable The diagram below shows cable assignment for GOT port Cables GT10 COOOR4 8P G
27. uld be checked by the user manufacturer For more details please contact the local Mitsubishi Electric sales site Requirement for Compliance with EMC directive The following products have shown compliance through direct testing to the identified standards and design analysis forming a technical construction file to the European Directive for Electromagnetic Compatibility 89 336 EEC when used as directed by the appropriate documentation Type Programmable Controller Open Type Equipment Standard Remark EN61131 2 2003 Compliance with all relevant aspects of the standard Radiated Emissions Programmable controllers Equipment requirement Compliance with all relevant aspects of the standard and tests ESD RF electromagnetic field EFTB Surge RF conducted disturbances and Power frequency magnetic field For more details please contact the local Mitsubishi Electric sales site Notes for compliance to EMC regulation 1 General notes on the use of communication cables Any device which utilizes a data communication function is susceptible to the wider effects of local EMC noise Therefore when installing any communication cables care should always be taken with the routing and location of those cables The GOT units identified on the previous chapter are compliant with the EMC requirement when the following communication cables are used GOT Unit Existing Cables GT1020 LBD GT1020 LBL GT1020 LBDW GT1020 LBLW GT10 C30R4 8P For
28. ure to observe this instruction may cause a malfunction 2 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within the premises Category II applies to equipment for which electrical power is supplied from fixed facilities The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V 3 This index indicates the degree to which conductive material is generated in the environment where the equipment is used In pollution degree 2 only non conductive pollution occurs but temporary conductivity may be produced due to condensation 1 2 Performance Specifications Specifications GT1020 LBD LBD2 GT1020 LBL GT1020 LBDW LBDW2 Type STN monochrome white black liquid crystal Item GT1020 LBLW Screen size 3 7 Resolution 160 x 64 dots Horizontal format Display size W86 4 3 4 x H34 5 1 35 mm inch Horizontal format Display character 16 dot standard font 20 characters x 4 lines Horizontal format Display section Display color Monochrome white black Display angle Left Right 30 degrees Top 20 degrees Bottom 30 degrees Horizontal format Contrast adjustment 16 level adjustment 200 cd m2 in green 300 cd m2 in white Life Approx 50 000h Time for display intensity to become 1 5 at operating ambient temperature of 25 C Intensity of LCD only LED with 3 available
29. yourself familiar with the operation method During test operation never change the data of the devices which are used to perform significant operation for the system False output or malfunction can cause an accident DANGER When power is on do not touch the terminals Doing so can cause an electric shock or malfunction Before starting cleaning or terminal screw retightening always switch off the power externally in all phases Not switching the power off in all phases can cause a unit failure or malfunction Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit CAUTION Do not disassemble or modify the unit Doing so can cause a failure malfunction injury or fire Do not touch the conductive and electronic parts of the unit directly Doing so can cause a unit malfunction or failure The cables connected to the unit must be run in ducts or clamped Not doing so can cause the unit or cable to be damaged due to the dangling motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault When unplugging the cable connected to the unit do not hold and pull the cable portion Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault Before touching the unit always touch grounded metal etc to discharge static electricity from human bo