1. Connector1 Power Supply port HD67510 A1 HD67510 B2 OV Ground V Positive wire V AC min 8V max 24V V DC min 12V max 35V ADFweb com S r l AT User Manual Modbus Slave Modbus TCP Master Document code MN67510_ ENG Revision 2 001 Page 9 of 30 Industrial Electronic Devices FUNCTION MODES The device has got two function modes depending on the position of the Dip2 of Dip Switch A The first with Dip2 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip2 of Dip Switch A at ON position is used for uploading the Project and or Firmware For the operations to follow for the updating see UPDATE DEVICE section According to the functioning mode the LEDs will have specific functions see LEDS section Dip Switch A Dip1 Must be at ON Dip2 Functioning Mode fn Normal Dip Switch A Dip1 Must be at ON Dip2 Functioning Mode A Warning Dip1 of Dip Switch A must be at ON position to work even if the Ethernet cable is not inserted ADFweb com S r l AT User Manual Modbus Slave Modbus TCP Master Document code MN67510_ ENG Revision 2 001 Page 10 of 30 Industrial Electronic Devices LEDS The devices has got four five for HD67510 B2 LEDs that are used to give information of the functioning status The various meanings of the LEDs are de
2. Industrial Electronic Devices UPDATE VIA SERIAL By pressing the Update Via Serial button it is possible to load the created configuration into the device and also the Firmware if is necessary This by using the RS232 port In order to load the parameters or update the firmware in the device follow these instructions gf Update Device by Serial Turn off the Device Connect the RS232 Null Modem cable form your PC to the Converter SW6 7 51 0 i Update Device Using the Serial Port Put Dip2 of Dip Switch A in ON position Select the COM port and press the Connect button o Foko tes or rer IO ete ee Eat 1 Turn OFF the Device Turn on the device 2 Use the Dip Switch to set the Boot Mode Check the Device state Led It must blink quickly see LEDS section 3 Select the COM Port for the Update Press the Next button coma Select which operations you want to do 4 Turn ON the Device Press the Execute Update Firmware button to start the upload XE Cancel When all the operations are OK turn off the device ey Put Dip2 of Dip Switch A in OFF position a Update Device by Senal Disconnect the RS232 cable Turn on the device SW675 10 Update Device Using the Serial Port At this point the configuration firmware on the device is correctly updated Haie Levies ORO Firmware V Read Firmware After Write Configuration Read Config
3. Industrial Electronic Devices User Manual Revision 2 001 English Modbus Slave Modbus TCP Master Converter Order Code HD67510 A1 HD67510 B2 For Website information www adfweb com Product HD67510 For Price information www adfweb com Price HD67510 Al1 www adfweb com Price HD67510 B2 Benefits and Main Features p Very easy to configure Low cost 32mm Rail DIN mount Wide supply input range Triple electrical isolation Temperature range 40 C 85 C 40 F 185 F User Manual ADFweb com S r l User Manual Modbus Slave Modbus TCP Master Document code MN67510_ENG Revision 2 001 Page 1 of 30 ai m slid C J HD67510 A1 HD67510 B2 For others products see also the following links RS232 RS485 USB Ethernet www adfweb com Product HD67118 RS232 RS485 Converter www adfweb com Product HD67119 USB RS485 Converter www adfweb com Product HD67038 RS485 RS232 Ethernet Converter CAN CANopen Modbus Modbus TCP www adfweb com Product HD67001 CANopen Modbus Master Converter www adfweb com Product HD67502 CANopen Modbus Slave Converter www adfweb com Product HD67011 CAN Modbus Master Converter www adfweb com Product HD67012 CAN Modbus Slave Converter www adfweb com Product HD67514 CAN Modbus TCP Master Converter www adfweb com Product HD67515 CAN Modbus TCP Slave Converter Modbus TCP Slave Modbus Master C
4. Routing Slave Address or Work with Fix IP Address SW6 7 5 1 0 see the description at page 16 Set Communication Setting The means for the fields of Modbus TCP master are a oe i i Work with Fix IP Address In the field IP Address insert the IP address that you want to give to the Converter Modbus TCP Master Modbus Slave Inthe field Subnet Mask insert the SubNet Mask a Gar SE RARR In the fields GATEWAY insert the default gateway that 192 168 you want to use This feature can be enabled or disabled Beate 25208 pressing the Check Box field This feature is used for SUBNET MaSK pani ONE going out of the net 255 255 ID Device 1 In the field Port the port used for Modbus TCP communication is defined In the field Timeout ms insert the maximum time a that the device has to attend for the answer from the Port 502 Slave interrogated If the field Don t disconnect the socket is checked when the Converter receives the TCP response it does E Don t disconnect the socket not disconnect the opened socket open the socket only at the first RTU request and then the socket remains opened otherwise for every RTU requests the Converter me FEN opens the socket and when it receives the TCP response it closes it F GATEWAY 192 168 TimeOut ms 1000 Fix IP Address Figure 3 Set Communication window ADFweb com S r l User Manual Modbus Slave
5. Master Document code MN67510_ ENG Revision 2 001 Page 15 of 30 By pressing the Settings gt button there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the 4 software Options software il Software Options SW67510 Language Connection Options Enable Internet Connection Check Software Update at Start of Program Check Available Update ADFweb com S r l See Language Connection Options Selected Language X English Fage i i1 In the section Connection Options it is possible to check if there are some updatings of the software compositor in ADFweb com website Checking the option Check Software Update at Start of Program the SW67510 check automatically if there are updatings when it is launched User Manual Modbus Slave Modbus TCP Master Document code MN67510_ ENG Revision 2 001 Page 16 of 30 Industrial Electronic Devices SET COMMUNICATION This section defines the fundamental communication parameters of two buses Modbus TCP and Modbus RTU By pressing the Set Communication button from the main window for SW67510 Fig 2 the window Set Communication appears Fig 3 The section Operation Mode defines the operation of the GB Set Communication Converter in Normal Mode with Translate Table
6. minimum version of the configuration software must be the 2 000 ADFweb com S r l AT User Manual Modbus Slave Modbus TCP Master Document code MN67510_ENG Revision 2 001 Page 27 of 30 Industrial Electronic Devices MECHANICAL DIMENSIONS amma d te TO O communication Dip Switch B B A AC of 12 35 DE a i cay WE Modbus Slave Modbus TCP Master Converter 100 HD67510 A1 me c EA T c O O www ADFweb com oe a f Enoret Qn e Dip Switch A C T N l s B185 MAC 10 64 E2 07 2E 6A l O BIEDA Denke tate lew Date Code 07 14 Serial Nr 00953 KoHS T 6 amp 4 I 120 mm E 4 72 inch 0 9 inch ea ch m Housing PVC Weight 200g Approx Figure 12 Mechanical dimensions scheme for HD67510 A1 QO OO I L OCO000 T1 mm 60 mm 2 79 inch 2 36 inch Housing PVC Weight 200g Approx Figure 13 Mechanical dimensions scheme for HD67510 B2 ADFweb com S r l AT User Manual Modbus Slave Modbus TCP Master Document code MN67510_ ENG Revision 2 001 Page 28 of 30 Industrial Electronic Devices ORDERING INFORMATIONS The ordering part number is formed by a valid combination of the following HD67510 A1 L Connectors Type 1 Removable 5mm Screw Terminal 2 Fixed 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting B 4M 35mm DIN Rail mounting Device Family HD67510 Modbus Slave Modbus TCP Master Converter Order Code HD67510
7. A1 Modbus Slave Modbus TCP Master Converter Housing type A Terminal Blocks Connectors Order Code HD67510 B2 Modbus Slave Modbus TCP Master Converter Housing type B Terminal Blocks Connectors ACCESSORIES Order Code AC34107 Null Modem Cable Fem Fem D sub 9 Pin 1 5 m Order Code AC34114 Null Modem Cable Fem Fem D sub 9 Pin 5 m Order Code AC34001 Rail DIN Power Supply 220 240V AC 50 60Hz 12 V AC Order Code AC34002 Rail DIN Power Supply 110V AC 50 60Hz 12 V AC ADFweb com S r l AT User Manual Modbus Slave Modbus TCP Master Document code MN67510_ENG Revision 2 001 Page 29 of 30 Industrial Electronic Devices DISCLAIMER All technical content within this document can be modified without notice The content of the document is a under continual renewal For losses due to fire earthquake third party access or other accidents or intentional or accidental abuse misuse or use under abnormal conditions repairs are charged to the user ADFweb com S r l will not be liable for accidental loss of use or inability to use this product such as loss of business income ADFweb com S r l shall not be liable for consequences of improper use OTHER REGULATIONS AND STANDARDS WEEE INFORMATION Disposal of old electrical and electronic equipment as in the European Union and other European countries with separate ps collection systems m This symbol on the product or on its packaging indicates that this p
8. CP Master Converter Opened Configuration of the Converter Begin Examplel Step 1 p New Configuration u Open Configuration Step 2 gt Set Communication Bj Translate Table Step 3 Step 4 aE Update via UDP ae Update via Serial wud ADERI CGH Figure 2 Main window for SW67510 ADFweb com S r l AT User Manual Modbus Slave Modbus TCP Master Document code MN67510_ ENG Revision 2 001 Page 14 of 30 Industrial Electronic Devices NEW CONFIGURATION OPEN CONFIGURATION The New Configuration button creates the folder which contains the entire device s configuration z5 SW67510 Create New Configuration Ed Create New Configuration Name of the new Configuration Example A device s configuration can also be imported or exported Ef Open Configuration To clone the configurations of a Programmable Modbus Slave Morbus TCP Master Converter in order to configure another device in the same manner it is necessary SW6 5 10 to maintain the folder and all its contents Open an Existing Configuration To clone a project in order to obtain a different version of the project it is sufficient List of Avaliable Configurations to duplicate the project folder with another name and open the new folder with the button Open Configuration Example2 ADFweb com S r l AL Industrial Electronic Devices SOFTWARE OPTIONS User Manual Modbus Slave Modbus TCP
9. Connector5 of HD67510 A1 HD67510 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To connect the device to a Hub Switch the use of a straight cable is recommended To connect the device to a PC PLC other the use of a cross cable is recommended Connector5 Ethernet Port RJ45 Plug _ a Oo a i oe CLF ea e p RS232 The connection from RS232 socket to a serial port example one from a personal computer must be made with a Null Modem cable a serial cable where the pins 2 and 3 are crossed It is recommended that the RS232 cable not exceed 15 meters The device is provided with a D sub connector type DE 9 Male also called DB 9 The cable must use a DE 9 Female connector The serial port is used for programming the device and for Modbus communication ii D N m 00 t T Tal Cable Cable Side A Side B Female Female ADFweb com S r l Vy User Manual Modbus Slave Modbus TCP Master Document code MN67510_ ENG Revision 2 001 Page 12 of 30 Industrial Electronic Devices RS485 To terminate the RS485 line with a 220 resistor it is necessary to put dip 1 ON like in figure Connectors RS485 Isolated port S Shield to Isolated Ground B Negative wire Positive wire S BA Dip Switch B Dipi R5485 Termination Resistor Open 220 Oh
10. Modbus TCP Master Document code MN67510_ ENG Revision 2 001 Page 17 of 30 Industrial Electronic Devices In the field Fix IP Address insert the IP address of the Modbus TCP slave device to which the converter sends the requests This field is visible only if the selected Operation Mode is Work with Fix IP Address The means for the fields of Modbus Slave are Inthe field Serial the serial lien to use for Modbus communication is defined RS232 or RS485 Inthe field Baudrate the baudrate for the serial line is defined Inthe field Parity the parity of the serial line is defined In the field ID Device the address of serial Modbus device is defined This field can be compiled only if the selected Operation Mode is Normal Mode with Translate Table or Work with Fix IP Address Operation Mode With this field is possible to select how the converter functions there are three options NORMAL MODE WITH TRANSLATE TABLE Using this function the Converter can be seen like a single serial Modbus slave The address of Modbus is assigned in the Set Communication section ROUTING SLAVE ADDRESS Using this function the Converter can be seen like more than one serial Modbus slave Each serial Modbus slave is a row of the table and it is possible to assign to which TCP device is linked WORK WITH FIX IP ADDRESS Using this function the Converter can be seen l
11. al al G ai In the field Slave ID insert the virtual address of the device will be the Converter In the field IP Address TCP insert the IP address of the device on the Modbus TCP that contains the data In the field Slave ID TCP insert the address of the device at TCP device If the field Reserved Socket is checked the converter will reserve a socket for the specific Modbus TCP slave This socket will be closed only after the number of consecutive errors defined in the Errors Sock column It is possible to reserve up to 3 sockets for 3 different Modbus TCP slaves function available only for Hardware Version with Dip Switches In the field Mnemonic you can insert a brief description Wereta SW67510 Set Translate Table Slave ID IP Address TCP j Slave ID TCP Reserved Sock frors Sock Mnemonic 192 168 0 18 5 a a O O O E O Esl Delete Row Insert Row Figure 6 Set Translate Table window ADFweb com S r l Industrial Electronic Devices EXAMPLE 1 Taking the first row of Figure 6 Step 1 A serial Modbus master do the request to the Converter to read write a register from the serial slave Modbus ID 1 Step 2 The Converter sends to the TCP slave 192 168 0 18 the read write request using the TCP slave ID 5 Step 3 The slave TCP replies to the Converter with the data Step 4 The Converter se
12. arning If Fig 11 appears when you try to do the Update try these points before seeking 5W67510 Serial Update M assistance INIT PROTECTION Check if the serial COM port selected is the correct one Check if the serial cable is connected between the PC and the device If you are using a USB DRS232 converter try with a native COM port or _ PROJECT PROTECTION change the converter BB Sw67510 Ethernet Update Try to repeat the operations for the updating j l Try with another PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista and 8 make sure that you have the administrator privileges In case you have to program more than one device using the UDP Update you have to cancel the ARP table every time you connect a new device on Ethernet For do this you have to launch the Command Prompt and write the command arp d Pay attention that with Windows Vista Seven 8 you have to launch the Command Prompt with Administrator Rights Take attention at Firewall lock FIRMWARE PROTECTION INIT PROTECTION FIRMWARE PROTECTION PROJECT PROTECTION Figure 11 Protection windows Warning A In the case of HD67510 A1 or HD67510 B2 you have to use the software SW67510 www adfweb com download filefold SW67510 zip ae Note lt The
13. ated Ground O LED4 Modbus TCP e vV OV cus satan pan Prisha Used for Programmation Port Modbus on RS232 To connect the device to the COM C communication Dip Switch B B 24V AC or f 12 35V DC k 1 9 y O Modbus Stave Modbus TCP Master Converter 300 port of a PC in order to set it you EEEE have to use the programming www ADFweb com A cable AC34107 or a cable made as f Jerome o BM gest CE showed here en ce BIN MAC 10 64 2 07 2E 6A Rail DIN O LED1 Devke state Date Code 07 14 Serial Nr C0953 wWoHS Clamp a e Ledi J Device state V OV Caa Dip1 RS485 Termination Resistor RS485 Isolated port Open 220 Ohm S Shield to Isolated Ground B Negative wire V Positive wire Dip2 Not used A Positive wire V AC min 8V max 24V V DC min 12V max 35V Figure 1a Connection scheme for HD67510 A1 ADFweb com S r l ADFweb com S r l Industrial Electronic Devices User Manual Modbus Slave Modbus TCP Master Document code MN67510_ ENG Revision 2 001 Page 6 of 30 Connectors S Shield to Isolated Ground B Negative wire Positive wire a al j RS232 D SUB9 Male Isolated port PIN2 RX PINS TX PINS GND to Isolated Ground Used for Programmation port Modbus on R5232 To connect the device to the COM port of a PC in order to set it you have to use the programming cable AC34107 or a cable ma
14. date Device Options V Firmware Read Firmware when finish Configuration Read Configuration when finish lt P Execute update firmware INIT Waiting Ver 1 101 FIRMWARE Waiting PROJECT Waiting Figure 10 Update device windows ADFweb com S r l AT User Manual Modbus Slave Modbus TCP Master Document code MN67510_ ENG Revision 2 001 Page 25 of 30 Industrial Electronic Devices If you know the actual IP address of the device you have to use this procedure Turn on the Device with the Ethernet cable inserted Insert the actual IP of the Converter Press the Ping button must appear Device Found Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK the device automatically goes at Normal Mode At this point the configuration firmware on the device is correctly updated K Note When you install a new version of the software if it is the first time it is better you do the update of the Firmware in the HD67510 A1 or HD67510 B2 device i Note A When you receive the device for the first time you also have to update the Firmware in the HD67510 A1 or HD67510 B2 device ADFweb com S r l User Manual Modbus Slave Modbus TCP Master Document code MN67510_ ENG Revision 2 001 Page 26 of 30 Industrial Electronic Devices A W
15. de MN67510_ ENG Revision 2 001 Page 22 of 30 Industrial Electronic Devices WORK WITH FIX IP ADDRESS Using this function the Converter can be seen like a single serial Modbus slave The address of Modbus is assigned in the Set Communication section In this mode of working is not necessary to compile a Translate Table every request that arrives on serial is transferred on TCP using TCP format of frame to the slave with the IP address defined in the Set Communication section EXAMPLE 1 Using the configuration of Figure 3 Step 1 A serial Modbus master do the request to the Converter to read write a Serial Modbus register from the RTU Slave Address 1 Master Step 2 The Converter sends to the TCP slave 192 168 0 20 the read write request Serial Modbus Step 3 The slave TCP replies to the Converter with the data Step 4 The Converter sends back the data on serial N Ce a oE Kl o Modbus TCP 10 100 Module oe Modbus TCP Step 3 Slave Figure 8 Chart of Request data from serial Modbus Note A If the TCP slave responds with an exception that exception code will be transmitted to the serial master If the TCP slave does not respond within the estimated time defined by the Timeout parameter an exception response will be given error code 36 ADFweb com S r l User Manual Modbus Slave Modbus TCP Master AL Document code MN67510_ ENG Revision 2 001 Page 23 of 30
16. de as V Positive wire VAC min 8V max 24V V DC min 12V max 35V Figure 1b Connection scheme for HD67510 B2 AT User Manual Modbus Slave Modbus TCP Master Document code MN67510_ ENG Revision 2 001 Page 7 of 30 Industrial Electronic Devices CHARACTERISTICS The HD67510 Al1 and HD67510 B2 are a Modbus Slave Modbus TCP Master Converter It allows for the following characteristics Triple isolation between Serial Power Supply Serial Ethernet Power Supply Ethernet Ethernet 10Base T 100Base T autosensing for Modbus TCP Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor SW67510 software on your PC in order to perform the following Define the parameters of Modbus TCP line Define the parameters of Serial Modbus line Update the device ADFweb com S r l User Manual Modbus Slave Modbus TCP Master AL Document code MN67510_ ENG Revision 2 001 Page 8 of 30 Industrial Electronic Devices POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below Consumption at 24V DC Device Consumption W VA Connector1 A Caution Not reverse the polarity power Power Supply port OV Ground k V Positive wire V AC min 8V max 24V OV V V DC min 12V max 35V
17. er Document Code and download the updates REVISION LIST Revision Date Author Chapter Description 1 011 18 12 2012 FI All Revision 1 012 24 01 2013 Nt All Added new chapters 2 000 12 02 2014 Fl All New hardware version 2 001 12 09 2014 Ff All Add new functions WARNING ADFweb com reserves the right to change information in this manual about our product without warning ADFweb com is not responsible for any error this manual may contain TRADEMARKS All trademarks mentioned in this document belong to their respective owners AT User Manual Modbus Slave Modbus TCP Master Document code MN67510_ ENG Revision 2 001 Page 3 of 30 Industrial Electronic Devices SECURITY ALERT GENERAL INFORMATION To ensure safe operation the device must be operated according to the instructions in the manual When using the device legal and safety regulation are required for each individual application The same applies also when using accessories INTENDED USE Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator i e independent limit switches mechanical interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of this equipment and who have ap
18. es to the Converter with the data Step 4 The Converter sends back the data on serial Figure 5 Chart of Request data from serial Modbus Module Modbus TCP Slave EXAMPLE 3 Taking the third row of Figure 4 Step 1 A serial Modbus master do the request to the Converter to read the Holding Register address 91 for 6 consecutive points Step 2 The Converter sends to the TCP Slave 192 168 0 18 the read request of Holding Register address 81 for 6 consecutive points Step 3 The slave TCP replies to the Converter with the data Step 4 The Converter sends back the data on serial J Note If the TCP slave responds with an exception that exception code will be transmitted to the serial master If the TCP slave does not respond within the estimated time defined by the Timeout parameter an exception response will be given error code 36 ADFweb com S r l User Manual Modbus Slave Modbus TCP Master Document code MN67510_ ENG Revision 2 001 Page 20 of 30 Industrial Electronic Devices ROUTING SLAVE ADDRESS Using this function the Converter can be seen like more than one serial Modbus slave Each serial Modbus slave is a row of the table and it is possible to assign to which TCP device is linked By pressing the Translate Table button from the main window for SW67510 Fig 2 the window Set Translate Table appears Fig 6 The data of the columns have the following meanings
19. ike a single serial Modbus slave The address of Modbus is assigned in the Set Communication section In this mode of functioning is not necessary to compile the Translate Table every request that arrives on serial is transferred on TCP using TCP format of frame to the slave with the IP address defined in the Set Communication section ADFweb com S r l User Manual Modbus Slave Modbus TCP Master AL Document code MN67510_ ENG Revision 2 001 Page 18 of 30 Industrial Electronic Devices NORMAL MODE WITH TRANSLATE TABLE Using this function the Converter can be seen like a single serial Modbus slave The address of Modbus is assigned in the Set Communication section By pressing the Translate Table button from the main window for SW67510 Fig 2 the window Set Translate Table appears Fig 4 The data of the columns have the following meanings Inthe field Data Type it is possible to select the type of data that is being considered Inthe field Address insert the address of the data on the serial device Converter Inthe field IP Address TCP insert the IP address of the device on the Modbus TCP that contains the data Inthe field Address TCP insert the address of the data on the TCP device In the field N Point insert the number of consecutive data that you want to configure For example you create Address 100 Address TCP 150 and N
20. lease do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve months it will be repaired or exchanged and returned within three weeks If the product is no longer under warranty you will receive a repair estimate ADFweb com S r l Via Strada Nuova 17 IT 31010 Mareno di Piave TREVISO Italy Phone 39 0438 30 91 31 Fax 39 0438 49 20 99 www adfweb com ADFweb com S r l
21. m Dip2 Not used Dip Switch B IConnector3 Dipi R5485 Termination Resistor R5485 Isolated port Al Open H 220 Ohm _ S Shield to Isolated Ground E 1 B Negative wire Dip2 Not used JA Positive wire The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foil shield braid shield Belden p n 82842 2x 24AWG stranded twisted pairs conductor foil shield braid shield Tasker p n C521 1x 24AWG twisted pair conductor foil shield braid shield Tasker p n C522 2x 24AWG twisted pairs conductor foil shield braid shield ADFweb com S r l AT User Manual Modbus Slave Modbus TCP Master Document code MN67510_ENG Revision 2 001 Page 13 of 30 Industrial Electronic Devices USE OF COMPOSITOR SW67510 To configure the Converter use the available software that runs with Windows called SW676510 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on our web site The software works with MSWindows XP Vista Seven 8 32 64bit When launching the SW67510 the window on the right appears Fig 2 Note It is necessary to have installed Net Framework 4 lt Ba ADFweb com Configurator SW67510 Modbus Slave Modbus Modbus Slave Modbus T
22. nds back the data on serial EXAMPLE 2 Taking the second row of Figure 4 Step 1 A serial Modbus master do the request to the Converter to read write a register from the serial slave Modbus ID 2 Step 2 The Converter sends to the TCP slave 192 168 0 19 the read write request using the TCP slave ID 1 Step 3 The slave TCP replies to the Converter with the data Step 4 The Converter sends back the data on serial EXAMPLE 3 Taking the third row of Figure 4 User Manual Modbus Slave Modbus TCP Master Document code MN67510_ ENG Revision 2 001 Page 21 of 30 Serial Modbus Master Serial Modbus o ODO t ie o Modbus TCP 10 100 Module Modbus TCP Slave Figure 7 Chart of Request data from serial Modbus Step 1 A serial Modbus master do the request to the Converter to read write a register from the serial slave Modbus ID 4 Step 2 The Converter sends to the TCP slave 192 168 0 20 the read write request Step 3 The slave TCP replies to the Converter with the data Step 4 The Converter sends back the data on serial J Note using the TCP slave ID 4 If the TCP slave responds with an exception that exception code will be transmitted to the serial master If the TCP slave does not respond within the estimated time defined by the Timeout parameter an exception response will be given error code 36 ADFweb com S r l AT User Manual Modbus Slave Modbus TCP Master Document co
23. onverter www adfweb com Product HD67507 www adfweb com Product HD67508 Do you have your customer protocol Then go to www adfweb com Product HD67003 Do you need to choose a device Do you want help www adfweb com Cmd helpme AT User Manual Modbus Slave Modbus TCP Master Document code MN67510_ ENG Revision 2 001 Page 2 of 30 Industrial Electronic Devices INDEX UPDATED DOCUMENTATION INDEX UPDATED DOCUMENTATION REVISION LIST WARNING TRADEMARKS SECURITY ALERT EXAMPLES OF CONNECTION CONNECTION SCHEME CHARACTERISTICS POWER SUPPLY FUNCTION MODES LEDS ETHERNET RS232 RS485 USE OF COMPOSITOR SW67510 NEW CONFIGURATION OPEN CONFIGURATION SOFTWARE OPTIONS SET COMMUNICATION UPDATE VIA SERIAL UPDATE VIA UDP MECHANICAL DIMENSIONS ORDERING INFORMATIONS ACCESSORIES DISCLAIMER OTHER REGULATIONS AND STANDARDS WARRANTIES AND TECHNICAL SUPPORT RETURN POLICY ADFweb com S r l p U U NNNNNNN BS BE BF FF Fe Re Q DOUNDDANRWHAUARAWNHEHOVANUBWNNNNNG Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page of this document With this Document Code go to web page www adfweb com download and search for the corresponding code on the page Click on the prop
24. point 5 the following gets set up automatically Addresses TCP 150 151 152 153 154 and the serial Modbus variables 100 101 102 103 104 Inthe field Mnemonic you can insert a brief description GB Translate Table SW67510 Set Translate Table IP Address TCP Address TCP NPoint Mnemonic 192 168 0 18 5 192 168 0 19 192 168 0 18 192 168 0 25 og OK Esl Delete Row Insert Row Figure 4 Set Translate Table window ADFweb com S r l User Manual Modbus Slave Modbus TCP Master Document code MN67510_ ENG Revision 2 001 Page 19 of 30 Industrial Electronic Devices EXAMPLE 1 Taking the first row of Figure 4 Step 1 A serial Modbus master do the request to the Converter to read the Coil Serial Modbus Master Status address 100 for 5 consecutive points Step 2 The Converter sends to the TCP Slave 192 168 0 18 the read request of Serial Modbus Coil Status address 150 for 5 consecutive points Step 3 The slave TCP replies to the Converter with the data ial O ODAO oO a Step 4 The Converter sends back the data on serial i ce W ye EXAMPLE 2 Taking the second row of Figure 4 Modbus TCP 10 100 Step 1 A serial Modbus master do the request to the Converter to read the Input Status address 110 Step 2 The Converter sends to the TCP Slave 192 168 0 19 the read request of Input Status address 100 Step 3 The slave TCP repli
25. propriate qualifications for their job RESIDUAL RISKS The device is state of the art and is safe The instruments can represent a potential hazard if they are inappropriately installed and operated by untrained personnel These instructions refer to residual risks with the following symbol This symbol indicates that non observance of the safety instructions is a danger for people that could lead to serious injury or A death and or the possibility of damage CE CONFORMITY The declaration is made by our company You can send an email to support adfweb com or give us a call if you need it ADFweb com S r l AL User Manual Modbus Slave Modbus TCP Master Document code MN67510_ ENG Industrial Electronic Devices Revision 2 001 Page 4 of 30 EXAMPLES OF CONNECTION Serial Modbus network RS232 pko a r Ie Modbus TCP network g 4 OOK o IL f Modbus RTU Master Modbus TCP Slaves HD67510 A1 Serial Modbus network RS485 Modbus TCP network Modbus RTU Master Modbus RTU Slave HD67510 B2 Modbus TCP Slaves ADFweb com S r l AT User Manual Modbus Slave Modbus TCP Master Document code MN67510_ ENG Revision 2 001 Page 5 of 30 Industrial Electronic Devices CONNECTION SCHEME Dip Switch A Dipi Must be at ON Dip2 Functioning Mode H Normal H Boot GLIH RS232 D SUB9 Male Isolated Port PIN2 RX PIN3 TX PINS GND to Isol
26. roduct may not be treated as household rubbish Instead it Should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent potential negative environmental factors and impact of human health which could otherwise be caused by inappropriate disposal The recycling of materials will help to conserve natural resources For more information about recycling this product please contact your local city office your household waste disposal service or the shop where you purchased the product RESTRICTION OF HAZARDOUS SUBSTANCES DIRECTIVE 4 The device respects the 2002 95 EC Directive on the restriction of the use of certain hazardous substances in electrical OHS and electronic equipment commonly referred to as Restriction of Hazardous Substances Directive or ROHS 2002 95 EC CE MARKING The product conforms with the essential requirements of the applicable EC directives ADFweb com S r l AT User Manual Modbus Slave Modbus TCP Master Document code MN67510_ ENG Revision 2 001 Page 30 of 30 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT For fast and easy technical support for your ADFweb com SRL products consult our internet support at www adfweb com Otherwise contact us at the address support adfweb com RETURN POLICY If while using your product you have any problem and you wish to exchange or repair it p
27. scribed in the table below LED Normal Mode Boot Mode Blinks quickly Boot state 1 Device state green Blinks slowly 1Hz i l Blinks very slowly 0 5Hz update in progress ON Ethernet cable connected ON Ethernet cable connected 2 Ethernet Link green l l OFF Ethernet cable disconnected OFF Ethernet cable disconnected 3 Serial communication Blinks when are received Modbus response Blinks quickly Boot state green frames RS232 RS485 Blinks very slowly 0 5Hz update in progress 4 Modbus TCP Blinks when are received Modbus TCP request Blinks quickly Boot state communication yellow frames Blinks very slowly 0 5Hz update in progress 5 Not used yellow present Blinks quickly Boot state OFF l only on HD67510 B2 Blinks very slowly 0 5Hz update in progress ES lt ii Led3 0 en Device state Ledi Yellow _ Serial communication f e Led2 Led4 Led3 Led2 Ledi Green 4 Led4 Yellow Green Green Green Ethernet Link y Yellow Modbus TCP communication Serial communication Ethernet link Device state N Modbus TCP communication g X praam Zz y Leds 2 a Yellow o D gt gt oO e rag OOO COOSSOCOO Not used ADFweb com S r l AT User Manual Modbus Slave Modbus TCP Master Document code MN67510_ ENG Revision 2 001 Page 11 of 30 Industrial Electronic Devices ETHERNET The Ethernet connection must be made using
28. uration After Write ap l Execute Update Firmware Ver 1 201 INIT Waiting ae FIRMWARE Waiting PROJECT Waiting Figure 9 Update Device windows ADFweb com S r l User Manual Modbus Slave Modbus TCP Master AL Document code MN67510_ ENG Revision 2 001 Page 24 of 30 Industrial Electronic Devices UPDATE VIA UDP By pressing the Update via UDP button it is possible to load the created configuration into the device and also the Firmware if necessary This by using the Ethernet port If you don t know the actual IP address of the device you have to use this procedure Update Firmware from Etherner UDP Turn off the Device Put Dip2 of Dip Switch A in ON position SW6 5 1 0 Update Device from Ethernet UDP Turn on the device Connect the Ethernet cable okie esse Hess Insert the IP 192 168 2 205 aka AASS ITIS Tea Press the Ping button Device Found must appear E T Se RC PEROT EN Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn off the Device Put Dip2 of Dip Switch A in OFF position Update Firmware from Etherner UDP Turn on the device SW6 510 At this point the configuration firmware on the device is correctly updated Update Device from Ethernet UDP Up