1. working within 5 30sec e After the first is out make it sense again after 5 10sec The load should work When there is no inductor signals in the indicator lamp the load should be stopped working within 5sec e Slide the LUX switch to MOON position it is in 10LUX the load should be not work in the daylight If you cover the detection window with the opaque objects towel etc the load work under no induction signal condition the load should stop working within 5 15sec Note when testing in daylight please slide LUX switch to xt SUN position otherwise the sensor lamp could not work FUNCTION e Can identify day and night automatically when turn to SUN max it will work day and night when turn it to MOON min it will only work in the ambient light less than 10LUX As for adjustment please refer to testing way e SENS adjustable It can be adjusted according to using location low sensitivity for small room and high sensitivity fits for large room e Time delay is added continually When it receives the second induction signals after the first induction it will compute time once more on the rest of the first time delay basis set time e Time delay is adjustable It can be set according to your desire the minimum is 5sec and the maximum is 8min Detection range 360 e Should be installed by electrician or experienced person e Avoid installing it on the unrest object e There should be
2. GL Wall Mounted Luminaires User s Manual Thank you for choosing the GL Wall Mounted Luminaires series LED products Please install and use the products according to the following directions to ensure the normal function and proper operation of the products If not to follow these instructions to properly install and normally use the products you will not get the warranty committed compensation or protection We will not take any responsibility for any product damage caused by improper installation or abnormal usage Specifications Type GL WL1012 GL WL1012 WW GL WL1012 CW Energy Used 11 5W Rated Life 30 000 Hours Input Voltage 100 240V AC Power Factor PF 0 88 120V AC 0 80 240V AC o o GL Wall Mounted Luminaires Outlook Applicable for both PIR and standard versions 86 4 47 2 CAUTIONS 1 The waterproof warranty of the light fixture will be void if the cap is removed WL1012 Sx PIR version excluded 2 The warranty period will last for two years since you buy the products If the product fails or malfunctions under the proper installation and normal usage within the warranty period please send it back to our company with our RMA approval or contact your local distributors for free repairing or replacing services 3 Please do not add remove any electrical components to from the products or change tamper the original electrical design without our permission 4 Please do not add remove any mechanic
3. al components to from the products or change tamper the original mechanical design without our permission 5 lease store or use the products in an environment meeting the temperature and humidity conditions designated by the product specifications Please do not uncover the GL Wall Mounted Luminaires series LED products lest waterproof and dustproof become invalid 6 To avoid any electrical shock or functional damage please do not insert any foreign objects into the products 7 For further information please contact us X GL WL1012 Sx PIR sensor GL WL1012 SL WW GL WL1012 SH WW gt il _ fN GL WL1012 SL CW GL WL1012 SH CW 100 120V AC GL WL1012SL 200 240V AC GL WL1012SH Ss wo o 96 105 RECYCLABLE PACKAGING ed o E BR GL WL1012 Sx PIR sensor PIR SPECIFICATION Ambient light 10LUX 2000LUX Choice Time delay 5sec 30sec 1mins 3mins 5mins 8mins Detection distance 6m max lt 24 C Detection range 360 Installation Height 1 8m 2 5m Detection Moving Speed 0 6 1 5m s e Slide the LUX switch oy to SUN position like the PIC below is SUN Slide the SENS switch A to maximum below is the maximum Adjust the TIME switch slide 5 switch to ON position slide upwards e When you switch on the power and preheat 30 seconds later the load is turned on in the absence of no inductor signals the load should be stopped
4. alified technical personnel C At the rear side of the LED fixture D 1 Installation for wooden ceilings or walls please connect the Live L and Fix trim extension with wood screws directly to the ceiling or wall B Please make sure that the specifications of the power A Before installation please turn off the power switch for the existing lamp Notices connector and the output Neutral N terminal are used for 2 Installation for concrete ceilings or walls voltage are compatible to connecting to power output Please a Refer to the picture above Place the trim extension to where you the LED fixture used follow the standard process to connect want to install it and mark the screw hole location them accordingly and do insulation on b Use a drill to drill a 6mm hole and WL1012 both terminal respectively insert the plastic crew anchor into Power Consumption 11 5W the concrete wall as in the picture Input Voltage max show below ee Use a hammer to lightly tap the WEteie Eames L Brown or Black anchor into the hole Repeat for Power Consumption 12 5W Input Voltage max each hole 100 120V AC 50Hz 60Hz c Screw the screws into the plastic WL1012 SH Power Consumption 12 5W Input Voltage max 200 240V AC 50HzZ 60Hz N Blue or White Green and Yellow 1 Do not change or tamper with any internal electric circuits or add in any wires or cables for any reason 2 Do not change the mechan
5. ical design circuit specifications or components do not add any other devices as this may cause the product to short circuit or may create other unforeseen risks 3 Keep the lamp set in a dry environment in order to avoid any electricity leakage 4 To avoid electrical shocks and possible malfunction please do not insert objects of any nature into the LED product screw anchor fixing the trim extension to the wall or ceiling 5 Do not touch while the lamp is on For any maintenance or replacement switch off the power and wait for 30 minutes to let the lamp cools down 6 For further information please contact with us Applicable for both PIR and standard versions Step 1 Turn the mounting latch anticlockwise 180 degrees OFF Step 3 Fix the mounting latch on the wall or the ceiling Turn the light fixture clockwise 180 degrees T Step 2 Connect the power cord to the light fixture 7 s Step 4 To finish the installation ensure the bolt sits well and firm in the latch All rights reserved All brand names and trademarks are the properties of their respective owners The specifications are subject to change without notice 17 WL101200001
6. no hindrance and moving objects in front of the detection windows to effect detection e Avoid installing it near air temperature alteration zones such as air condition central heating etc e Considering your safety please do not open the cover when you find the hitch after installation e f there is difference between instruction and the function the product has please give priority to product and sorry not to i nform you additionally SOME PROBLEM AND SOLVED WAY e The load do not work a Please check if the connection wiring of power and load is correct b Please check if the working light sets correspond to ambient light e The sensitivity is poor a Please check if there has hindered in front of the detection window to effect to receive the signal b Please check if the ambient temperature is too high c Please check if the induction signal source is in the detection fields d Please check if the installation height corresponds to the height showed in the instruction e Please check if the moving orientation is correct e The sensor can not shut off the load automatically a Please check if there is continual signal in the detection field b Please check if the time delay is the longest c Please check if the power corresponds to the instruction d Please check if the temperature near the sensor changes obviously such as air condition or central heating etc HOELEN p Installation procedure should be undertaken by qu