1. H RUNE Portable menstrual pain relieve 200L 2012 05 Rev 2 0 User Manual Read this manual before using the product for safety and use the product properly vi Ver 1 1 2010 05 CONTENTS Preparation How to use O O O O A Others 14 16 17 Product features Specification Quick guide Names and functions of each part pad and patch How to insert battery and charge How to use How to handle and keep Troubles Limited warranty Read this part before using the product m Dangers warnings cautions and information specified in this manual are to encour age you to use the product properly and to prevent damages to people or property due to inappropriate use m You should follow the points below specified in this manual m Medirune expressly disclaims all damage resulting from breakdown or injury due to random disassembly or careless handling m Keep this manual at hand for reference m he following are the points and their meanings specified in manual Ver 1 1 2010 05 Specification Components P m E Regulator Li ion battery Main pad Patch Connection wire Patch type Separately sold OB MA coll EN Se Gel Pad type User manual Holder Pad type Stomach belt Recharging adapter cable Product Personal combination stimulator Model name 200L advanced type Product name Portable menstrual pain reliever Power sup
2. off F Heat mode selection switch used for patch connection Charging jack Used for charging battery Pad patch connection jack Plug the pad patch connection cables Pad and Patchs 2 Indicators and features for pads and patch E Patchs used for menstrual pain relief and low frequency features I Connection cord joining the pad connection cable Electrode part attached to the affected area for stimulation E Pad used for heat feature When the product is first used the gel is adhered with transparent film From both sides the shaded area semi transparent is to be detached and then attach it to the pad Electrode part attached to the affected area for stimulation CG Heat part attached to the affected area for heat therapy Connection cable amp connector connected to the patch connection jack on the controller Ver 1 1 2010 05 How to insert battery and charge 1 How to insert battery 1 Turn off the ON OFF switch placed on the lower right end part of the controller 2 Press the upper part of the battery cover with your hand and press it to the arrow direction 3 Fit the metal contact of battery into the charging part and press it down Then fit the cover into groove and fix tt 2 How to charge battery 1 When the battery level indicator shows fewer than one bar stop using the unit and turn it off 2 Separate the char
3. Restart by power switch when the connection wire of the patch is re connected to controller If the patch or connection wire is broken call our customer center requesting replacement or repair RS Ver 1 1 2010 05 How to use 3 Low frequency stimulus mode additional feature There are 4 modes Click the switch once for pressing twice for tapping three times for oretissage and four times for auto mode once twice three times four times Once a mode is selected it operates in 2 sec The LCD shows the selected mode icon blinking every 0 5 sec meaning it is working Initial intensity is set to OO Using the intensity control switch you can control and indicate the intensity you want lee menstrual pain relief mode GD The operating time is set to 20 min Over time the remaining time is indicated on the LCD See menstrual pain relief mode In operation when no switch input is given for 30 sec the HOLD mode begins See menstrual pain relief mode Press the HOLD release switch on the main unit for 2 sec and the HOLD is off Then the LCD shows current operation status Afterward if no switch input is given for 30 sec another HOLD begins See menstrual pain relief mode Sensitive users may get a shock depending on intensity So be careful with the intensity control You must consult a specialist first if you have one of the following symptoms Medirune e
4. The adhesion of the pad or patch is detached The attached part is not adhered on the skin The intensity adjustment is weakened j he battery has been discharged Use it after recharging j he service time of 20 minutes has been exhausted Please use it again he transparent film of the attached side is not removed he attached side is dirty that it has to be washed before using it After washing it off wiping off the moisture The attached side is damaged that it has to be replaced with new one lf the remaining battery is insufficient recharge tt The patch is connected The connector of the pad is not connected or it is short circuited Do not use after 20 minutes of continuous use When the attached side is dirty or dried the attached part is washed off with water When the attached side is damaged replace it with new one since the pad and gel are dispensable goods i you have skin problem or skin disease stop using the product and consult with physician Ver 1 1 2010 05 Limited warranty Troubles Limited Warranty 1 You are entitled to a 1 year warranty service for defects under normal use according to the user manual and other caution phrases on the labels attached to the controller The limited warranty menstrual starts on the date of purchase 2 If you need receive any repair service within the limited warranty menstrual visit our web site or Call our s
5. angwon Do Korea declares that the medical device described hereafter Product name Period Pain Reliever Model Name 200L has been classified as Class Ilo Annex IX Rule 1 9 and is in confor mity with the essential requirements and provisions of Council Directive 2007 47 EC is subject to the procedures set out in Annex Il of Directive 2007 47 EC under the supervision of Notified Nemko AS ND No 0470 P O Box 73 Blindern N 0314 OSLO Norway Safety Performance EN 60601 1 1990 A1 1993 A11 1993 A12 1993 A2 1995 A13 1996 EN 60601 2 10 2000 A1 2001 EN 60601 2 35 1996 EMC EN O60 1 1 2 2 2007 29 January 2010 President Kang S W Ver 1 1 2010 05 19 Medirune Co Ltd Medirune www medirune com 3 206 207 Medical device industrial complex 1720 26 Taejang Dong Wonju Gangwon Do 220 120 Korea Tel 033 765 5739 Fax 033 765 5793 EC REP European representative Vario Tech GmbH Ludwig Erhard Str 30 34 65760 Eschbom Germany Tel 49 6196 7755 945 ISO 138485 NO 908145 ISO 9001 NO 800438 CE o
6. armer sold separately for the maximum effect 3 Turn on the power 1 Check if the power switch is off at the bottom of the controller 2 Insert the battery with correct polarity and then turn on the controller 4 Select the mode 1 TE N S Mode Basic 20 minutes A B C Mode A menstrual pain acute pain di IO Mode B menstrual pain chronic pain and backache a d dl el Mode C menstrual pain 2 Heating Mode Basic 20 minutes Select H High or L Low If the product in the T E N S mode it cannot be used for the heating mode 5 Select the intensity level Use the Up Down buttons on the top left of the controller to control the intensity level How to Use the Low Frequency Patch YV 1 Connect the patch with the regulator Sa yt A Ro W Plug the patch cable to the bottom of the regulator 2 Apply the patch to the pain area Remove the protection film from the patches Apply the patches to the pain area symmetrically Keep the film to protect the patches DL 3 Turn on the power Se DD i 1 Check if the power switch is off at the bottom of the controller _ Battery ST 2 Insert the battery with correct polarity and then turn on the controller Wm Terminal 1 4 Select the mode ay Low Frequency Switch Select Press Tap Mass or Auto PRESS Ze AUTO _ MASS UP 5 Select the intensity level 8 d Use the Up Down buttons on the top left of the W controll
7. cator on the LCD shows the selected mode icon blinking every 0 5 sec Initial intensity control is set to 00 With the control switch you can control the intensity which is indicated as below i gt H o DE Oe click once ae 15 times GD Operating hour is set and indicated as 20 min Over time remaining time is showed on the LCD gt EESE ES gt EENT in 1 min tits in 19 min While in operation if the Hold relese button is pressed for 1 sec the HOLD state begins gt E press for 1 sec If the HOLD release button on the main unit is pressed for 2 sec the HOLD is released and current operation status is indicated Then if no switch input is given for 30 sec it goes into HOLD state again gt press for 2 sec in 30 sec Caution Do not use the product around the heart the neck the abdomen the head the pubic region the parts injured or infected or skin trouble and in the mouth Restart by power switch when the connection wire of the patch is re connected to controller If the patch or connection wire is broken call our customer center requesting replacement or repair Do not disassemble repair or alter the product randomly to avoid fire accident and malfunction 11 How to use 2 Heat mode when using patch There are consisted 2 modes Press the switch once for strong mode Press it twice for weak mode Press it thr
8. continuously use the product for over specified time 20 min on one spot It may cause muscles to get tired leading to abnormal conditions Do not use it around shortwave or microwave treatment equioment min 1M 4 Fix the pad or patch to the holder Information Make sure a couple of pads do not stick together Keep the pad or patch always clean Be careful not to leave your hand prints on the electrode pad or patch It could deteriorate adhesive strength See how to handle and keep Do not yank the pad or patch connection cables or do not bend the patch forcefully and unnecessa rily It could cause a malfunction The gel for pads or patch is consumables When the adhesive surface is damaged purchase new products sold separately Be careful not to touch the adhesive surface Hold the handle while taking it off If the adhesive surface is too sticky or comes off put it in the refrigerator for overnight to restore adhesive force If a piece of paper tissue sticks to the adhesive surface do not take it off forcefully but add a little water then it will come off easily 14 Ver 1 1 2010 05 How to handle and keep 3 How to maintain and checkup the product 1 To prevent accidents use the parts the manufacturer recommends or sells 2 a Do not alter or disassemble the product which will cause damage malfunction injury and accidents 3 4 See Do not soak th
9. e product in water If it is soaked in water wipe it out immediately with a dry fabric Se f 3 happens inquire of a local selling agent or our home page 4 How to dispose of the product n accordance with the ordinances of each local municipality disoose of the product appropriately Do not use hot water detergents and chemicals thinner benzol etc Do not cause scratches to the adhesive surface with fingernails or brushes Avoid frequent and long wash Do not keep it in a hot and humid place with direct sunlight Do not wipe out the adhesive surface with tissue or fabric When wash them with water becareful not to get pad connector and patch connector inside wet with water It could cause a malfunction When substances with high thermal conductivity like the patch gel are used without turning on the heat feature patients body temp could drop When the product malfunctions or you feel something wrong with your body while using it stop it immediately Consult a doctor for body or skin trouble and follow the doctor s instruction To attach a pad or patch to other parts while using the product be sure to convert the intensity control button to 00 position and then attach it Otherwise it could cause a strong electric shock Do not start other treatment while wearing the product It could affect the product s setting and timing Do not use the product with infants or those
10. ee times for waiting mode after turn off heat mode gt once twice HEAT H 666 times three When selecting a mode in 2 sec operation starts The LCD shows the selected mode icon blinking every 0 5 sec to indicate it is working i Ee Es ES 0 5 sec 0 5 sec The operating hour is set and indicated as 20 min Over time the remaining time is Press the HOL OT In and indicated on the LCD See menstrual pain relief mode See menstrual pain relief mode During operation if no switch input is given for 30 sec the HOLD state begins D release switch on the main unit for 2 sec and the HOLD is released Then current operation status is indicated If no switch input is given for 30 sec another HOLD begins See menstrual pain relief mode ER Information he heat mode can be used only when the patch is connected only the weak pain mode works menstrual pain mode heat mode can be added Click the heat switch 3 times and the heat mode stops When the battery level shows less than one bar the heat may not work Recharge the battery OS O mall stimulation does not mean the treatment process is not working stimulation Different people feel different intensity In heat mode if any abnormality bimetal temp sensor trouble etc arises the buzzer goes off five times and the LCD indicates the stand by state
11. er to control the intensity level Medical Device amp Product development Names and functions of each part 1 Switches connectors and indicators Intensity control display H Rune vong comes mi Ers HEAT Tal L Battery status display enstrual pain f relief mode display Low frequency stimulus mode display HOLD fuction amp timer display Heat mode display mt Ver 1 1 2010 05 Names and functions of each part Intensity control switch Used for menstrual pain relief mode and low frequency feature mode From 00 to 15 step one click leads to the next step Once reaching step 15 no further does the step go up At the max 15 step each click on switch will lower the intensity At 00 step no further does the step go down HOLD release switch Under HOLD condition no switch input works 2 Ssecond press of the HOLD release switch will undo HOLD then mode change intensity control and mode addition features are available CG Power switch Slide up down the switch to turn it on off Low frequency selection switch additional feature Click once for pressing twice for tapping three times for massage four times for AUTO Menstrual pain relief switch Click once for relief A twice for relief B three times for relief C Click once for strong heat twice for weak heat
12. ervice center 3 The limited warranty is not applied to the items below 1 Troubles or damage resulting from user s mistake or inappropriate repair or replacement or alteration 2 Troubles or damage due to intentional or accidental dropping of product after purchase 3 Defective functioning or damage attributable to fire earthquake flood lightning thunderbolt other natural disasters pollution surge and abnormal power supply not specified voltage frequency etc 4 Conditions not provided in this manual 5 When the date of purchase customer s name and seller s name are not written in this manual or when such records are modified 6 Consumables 7 When the cause of defective functioning does not lie in this product 8 Defects or damage by using the product in a way not specified in this manual 4 This manual is not reissued Don t lose this manual Keep it carefully 5 This document includes limited warranty information under the terms and conditions and within the specified menstrual This document of limited warranty does not restrain you of your legal rights Ser Limited Warranty Customer Place of purchase Address Address Seller s name Product name Date of purchase dd mm yy Model name 1 year warranty from the date of purchase medirune co Ltd 17 CE Declaration of conformity medirune Co Ltd 3 206 207 Medical device industrial complex Taejang Dong Wonju G
13. ging jack on the lower left of end of the unit with your fingernail Join it to the charging jack with the charging lamp arrow of the USB charge cable and charging adaptor facing up lamp red charging green fully charge 8 19 S9 0 Spiecht EIER H LO EP Information Upon purchasing the product is not fully charged Charge it fully before use Battery is consumables so its working time gets shorter over time When the working time is shortened by a half purchase a new one Limited warranty menstrual is 6 months from the date of purchase USB cable is connected to PC for charging While charging if the lamp is blinking remove the connector and re plug it in If the same symptom persists after 4 times of trial call the service center When the battery life remains by less than 10 the battery icon blinks and the buzzer goes off to make beep sounds three times While charging the unit cannot work Use the specified battery only Do not remove the battery cover while the product is working When applying the battery to the unit do not add too much pressure How to use 2 Starting Starting is about how to turn on the power before use 1 Slide up the switch on the unit to turn on the power 2 When the power is turned on the buzzer goes off once and every item is showed
14. on the LCD for 2 sec then the stand by state begins with the LC the battery level D showing only GeV OR m Oe gt Power ON ll D D CG HEAT 55 4 1 after 2sec 3 After the stand by state you can select the mode Information Once the power is turned on if no switch input is given for 30 sec the unit is automatically turned off To restart the power turn down the power switch and then turn it on When connect patch cannot be use heat mode when connect pad can be use heat mode Caution Upon turning on the power do not switch on the intensity controller abruptly Too strong intensity may cause a shock A Danger The following medical equioments cannot be used together with this product Otherwise Such equipments will malfunction Consult a specialist first Implantable electronic medical equipment like pace maker Life support electronic medical equipment like ventilator Pluggable electronic medical equipment like ECG recorder Do not use the heat unit along with RF surgical unit cardiac catheter and surgical medical equipment 10 Ver 1 1 2010 05 How to use 3 Mode selection and operation 1 Menstrual pain relief mode There are 3 modes By clicking the switch once you can choose A B or C mode Waa gt three times VOR once twice On selecting a mode it takes 2 sec to start the mode operation The indi
15. ply DC 3 7V 1100mA Li ion rechargeable battery Battery life span ax 20 hour with TENS used Max 2 hour with heat TENS used Battery charging time Approx 300 minutes It depends on the conditions Operating hour 20 min default Heat feature Strong 40 C 1 C Weak 37C 1T Unit size 9Omm X 52mm X 18mm Unit weight 78g Battery included 50g Battery excluded Patch amp patch connection cable 50mm X 88mm X 2mm 2sets included 1M Pad amp pad connection cable 145mm x 65mm X 4mm 2sets of conductive gel included 54mm 35mm Xx 2mm 05M Rechargeable adaptor Separately sold Operating environment Temp 20 C 40 C Humidity 30 85 Pressure 70 106KPa Transport amp store environment Temp 20 C 60 C Humidity below 95 Pressure 70 106KPa Unit class and type Class Internal power equioment BF type Standard EN60601 1 electric mechanical safety test EN60601 1 2 EMI test Quick guide How to Use the Main Pad MIEN br i Sj ON if Soo Wj L Battery Terminal HEAT n L 0 000 Medirune 1 Connect the main pad with the regulator Plug the pad cable to the bottom of the regulator 2 Apply the main pad to the pain area Remove the opaque film from the pad gel Attach it to the main pad with correct polarity and then apply the main pad to the pain area Use the transparent flm 7 delivered with the product to protect the pad gel Use the abdominal w
16. who cannot express themselves properly It could cause accidents or diseases Avoid wet places like bathrooms when using the product Do not use it while taking a bath or shower It could cause a severe electric shock Do not use the product while sleeping It could cause malfunction or the pad or patch unnecessarily move to other body parts Do not use it while driving If it is affected by some strong stimulation it could cause accidents or problems After using the product do not leave the pad or patch attached to the skin Extended attachment could cause itches or troubles or infections on skin 15 Troubles Problem Power is not on Power is on but no stimulus is felt Too weak stimulus Power is off while in use Less adhesive pads or patch No heating In the event of having possible skin problem during the use 16 Measures If the battery is not fit it appropriately check the polarity to re insert i the battery is discharged charge it again for re use Check if the attached side of pad or patch is detached from the skin and then adhere the attached part to the skin Check if two patches are connected to a connection line for one Connection to the connection line is not made Check if the intensity adjustment is set for 00 and then adjust the intensity Check if the patch is overlapped for attachment
17. xpressly disclaims any damage resulting from using the product without consulting a doctor You must make sure if it is OK with you to use the product when you have the following symptoms 1 Acute diseases tumors cardiac dysfunction thrombus high fever abnormal blood pressure diabetes 2 Dermatomal sensory loss derrmatosis 3 Abnormal nerve sensations and blood circulation 4 Other diseases and complications The disabled infants pregnant women and mentally ill people must not use the unit Those who have difficulties controlling body and sensing heat and subjective symptoms drinkers and sleeping pill takers must not use the product 13 How to handle and keep 1 How to arrange the unit 1 Turn the power switch off Remove the pad connector and patch connector from the main unit 2 Remove the pad or patch attached to the affected area 3 Fix the pad and patch to the holder 2 How to clean the patch 1 Turn off the power Separate the pad or patch from the connection cable 2 Use your fingers to gently clean the patch in small amount of running water for seconds Be careful to keep the connection cord of the pad and the connector of the patch away from water 3 Remove moisture completely Try a natural dry for the adhesive surface K OK goa storage A Warning Medirune expressly disclaims any damage caused by not observing the cautions and other particular guidance mentioned here Do not