1. Engine Interface JX Module MBW Technologies ns supp Engine interface Module co so Po pN EM1005P 50 i Fuel Water We YMJH O Installation amp User Manual Replaces i8305 used on LP LY2 JH Yanmar Engines Email sales mbwtech com MB Ww Tec Anologies LLC Phone 267 932 8573 x340 www mbwtech com EM1005xX Installation User Manual MBW Technologies LLC 2 Year Limited Warranty Electronic Modules and Displays MBW Technologies LLC MBW warrants its Electronic Module and Display products to be free from defects in materials and workmanship for a period of two 2 years from the date of shipment by MBW Within this period MBW will at its sole option repair or replace any Electronic Module or Display that fails in normal use and is returned to MBW freight prepaid within the warranty period MBW is not responsible for charges connected with the removal of such product or reinstallation of replacement or repaired parts This warranty does not cover failures due to abuse misuse accident faulty installation or unauthorized alteration or repairs THE EXPRESS WARRANTY SET FORTH ABOVE IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Statements made by any person including representatives of MBW which are inconsistent or in conflict with the terms of this Limited Warranty sh
2. Dip Switch Locations and Settings 8 Copyright 2010 MBW Technologies LLC All Rights Reserved EM1005xX Installation User Manual Installation Notes Existing Installation Boat Type Engine Model System Voltage Number of Engines Number of Stations USA or European Install Display Gauge Type Fluid Tanks Existing Network Trim Measurement Engine Hours Copyright 2010 MBW Technologies LLC All Rights Reserved EM1005xX Installation User Manual MBW Technologies LLC 2080 Detwiler Rd Suite 1 Harleysville PA 19438 Sales 267 932 8573 x340 Email sales mbwtech com Email support mbwtech com OR Contact your local Yanmar Dealer P N MN10008 50 Copyright 2010 MBW Technologies LLC All Rights Reserved
3. CLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Statements made by any person including representatives of MBW which are inconsistent or in conflict with the terms of this Limited Warranty shall not be binding upon MBW unless reduced to writing and approved by a manager of MBW NMEA 2000 isa registered trademark of the National Marine Electronics Association IN NO EVENT SHALL MBW BE LIABLE FOR ANY INCIDENTAL SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES WHETHER RESULTING FROM THE USE MISUSE OR INABILITY TO USE THIS PRODUCT OR FROM DEFECTS IN THE PRODUCT Some states do not allow the exclusion of incidental or consequential damages so the above limitation may not apply to you MBW retains the exclusive right to repair or replace the cable or connector or offer a full refund of the purchase price at its sole discretion SUCH REMEDY SHALL BE YOUR SOLE AND EXCLUSIVE REMEMDY FOR ANY BREACH OF WARRANTY Warranty Return Procedure To obtain warranty service contact MBW Technical Support Department at 267 932 8573 x341 or email Support mbwtech com to describe problem and determine appropriate action 2 Copyright 2010 MBW Technologies LLC All Rights Reserved EM1005xX Installation User Manual Table of Contents Product Oy Cl VIG W carakane ppan Aona 4 COMPONENTS Jimaa a ener a marr e re 4 Mstalhine thes yS ic oy eena tame tre nnr renee reese atte er ee eer ae 4 Makine the Connect
4. M NMEA 2000 DROP NMEA 2000 BACKBONE cess Copyright 2010 MBW Technologies LLC All Rights Reserved 5 EM1005xX Installation User Manual Pre power Check List L Wires are free from abrasive and puncturing materials Network connections appropriately strain relieved and T connectors mounted with screw or tie wrapped to secure surface O Harnesses are properly dressed and strain relieved L Check optional connection for fluid level input If not used secure the harness using proper harness strain relief Power up amp Initial Configuration With final checks complete turn on the engine and house battery switches At the main station turn ON the engine ignition via the rocker or keyswitch depending on panel type installed Turn switch to On position Check the following and repeat for additional engines L Alarm sounds for approximately 2 seconds O All displays light up starting with the splash screen LI The engine data should be present on the displays i e Tachometer is 0 RPM Dock Side Checkout L System alarm check sounded when ignition was turned On L With engine running verify that the display s are showing proper engine data System Options The EM1005x Product is designed as a Plug N Play data monitoring system for Yanmar Mechanical Engines that replaces the Teleflex i8305 but if it is used with the M700 display additional features are available e Sensor 2 input c
5. all not be binding upon MBW unless reduced to writing and approved by a manager of MBW IN NO EVENT SHALL MBW BE LIABLE FOR ANY INCIDENTAL SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES WHETHER RESULTING FROM THE USE MISUSE OR INABILITY TO USE THIS PRODUCT OR FROM DEFECTS IN THE PRODUCT Some states do not allow the exclusion of incidental or consequential damages so the above limitation may not apply to you MBW retains the exclusive right to repair or replace the electronic module or display or offer a full refund of the purchase price at its sole discretion SUCH REMEDY SHALL BE YOUR SOLE AND EXCLUSIVE REMEMDY FOR ANY BREACH OF WARRANTY MBW Technologies LLC 1 Year Limited Warranty Cables and Connectors MBW Technologies LLC MBW warrants its Electrical Cable and Connector products to be free from defects in materials and workmanship for a period of one 1 year from the date of shipment by MBW Within this period MBW will at its sole option repair or replace any electrical cable or connector that fails in normal use and returned to MBW freight prepaid within the warranty period MBW is not responsible for charges connected with the removal of such product or reinstallation of replacement or repaired parts This warranty does not cover failures due to abuse misuse accident faulty installation or unauthorized alteration or repairs THE EXPRESS WARRANTY SET FORTH ABOVE IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED IN
6. an be configured for Fuel Water Waste or Rudder Angle e Amaintenance timer is enabled 6 Copyright 2010 MBW Technologies LLC All Rights Reserved Ordering the System EM1005xX Installation User Manual The i8305 is configured using DIP switches for determining the EIM location Port or Starboard and configuring the tachometer pulses per revolution PPR to match the engine flywheel teeth count Another parameter stored is the engine hours Should the EM1005x be ordered without the M701x Display this data must be defined when placing the order See Table Below ENGINE POSITION ENGINE HOURS SENDER 2 INPUT FLYWHEEL COUNT Port or Starboard xxx x Hours Defaults Fuel Tank 3 for Port Fuel Tank 4 for Starboard Can be configured via M701x for Water Waste Rudder Angle or Not Used 129 127 117 116 or 97 LY2 129 LP 117 JH4 116 JH4T 127 YM 97 Note 1 A charge alarm will activate the EM1005x alarm output but may not be present on the TFX i5601 display Note 2 Boost Alarm over boost is not available Copyright 2010 MBW Technologies LLC All Rights Reserved 7 EM1005xX Installation User Manual Reading the configuration settings of the i8305 requires removing the top cover and noting the DIP switch settings See Table below ee ie oe PPR 97 PPR 114 pm fm fe fk PPR 116 ee ee a PPR 129 X 87 65432 1G i8305
7. ions sursis nina 4 Ememe Interface Modules aa OAAR 5 Pre power Check EiSEceninaninneninretnironi ioan cenieaomatnen 6 Power up amp Initial Configuration ec esesssestessesseestecseeseestesseeseeseestesseeseeseestesueeneenteseeseens 6 DOCK Sde CRECKOU Foroinn trge nrr nt TEENA KEAN AATE AEE ERTE 6 SYSE M O DUONS aper i savannas asnitabin Seana Aah 6 Ordering the SysteNi erence sen teeenin ens tome eterna renee nner ite ere ee ee ener ren 7 Tis tala On Noles sisanne n Oaa AEAEE a AR EEEa 9 Copyright 2010 MBW Technologies LLC All Rights Reserved 3 EM1005xX Installation User Manual Product Overview The EM1005 Product is designed as a Plug N Play data monitoring system for Yanmar Mechanical Engines that replaces the Teleflex i8305 Review the Ordering the System section for proper unit configuration Components EM1005X 5X_ EM Eng Interface Module MN10009 5X_ Data Sheet EM1005X MN10008 5X_ Manual Install User EM1005X M701X Display Single or Dual replaces Teleflex i5601 1000005 XX Buzzer 12 volt XX Denotes part number option for length position or model Installing the System The safety messages that follow have CAUTION level hazards ALWAYS ensure the power supply is OFF and battery cables are disconnected before you make any electrical connections Before removal of the i8305 verify that the mating connectors are clearly marked from P1 to P6 If not label each connector prior to di
8. sconnecting from the i8305 Making the Connections Each EIM connector is marked with a connector designator J1 J2 J4 J5 and J6 Match the labels with the corresponding i8305 boat harness connector P1 P2 P4 P5 and P6 The NMEA connection is made directly to the NMEA 2000 Network via the Communications T so P3 is not used Care must be taken as all of the connectors are interchangeable and must be mated based on their designation The supply power MUST be OFF when interconnecting the system 4 Copyright 2010 MBW Technologies LLC All Rights Reserved EM1005xX Installation User Manual Engine Interface Module 1 Before removal of the i8305 verify that the mating connectors are clearly marked from P1 to P6 If not label each connector prior to disconnecting from the 18305 2 Mount the EIM in the same location as the i8305 using the appropriate mounting hardware for the mounting surface structure with two user supplied fasteners 3 Mate the 5 engine interface connectors marked J1 J2 J4 J5 J6 routing the harness toward the mating connectors fa T E lol EM1005X se rt 6 amp 6 5 ee ULL q ar 4 i lajm iF 4 Add the EIM drop cable as shown below Remove the communications cable from the T connector that was mounted in P3 location Connect the NMEA communications cable from the EM1005x module Secure the harness using appropriate tie straps or cable clamps e ENGINE ROO
Download Pdf Manuals
Related Search
Related Contents
Toshiba 84LM9600 Flat Panel Television User Manual DP2 SERIE PRINCE 300/500/700/1000W Manual 2040 Set3x7x - KOREA Mtt Installation and Operating Instructions Manual de Utilização AL-2765 CS 4008 NUMERIC UNDERPINNER ( Technical and User Manual ) 型式番号 作成年月 燃料電池ユニット 平成25年3月 NA-0813ARS MultiQ 215, User Guide Fellowes Powershred 63Cb User's Manual Copyright © All rights reserved.