Home
TorqueStar Opta QSGuide 2a
Contents
1. ENTER Press keys and ES on the keypad to move between pages and press the key to return to the Quick Measure mode Printing from the TorqueStar Opta O The TorqueStar Opta can be set to automatically send its readout data to a serial printer To do this first attach a suitable printer such as the Epson LX 300 to the TorqueStar Opta The printer cable attaches to the 9 way D connector at the rear of the TorqueStar see Rear View overleaf Press ES on the keypad to toggle between Autoprint ON or OFF The Icon will show a tick or a cross to indicate Autoprint ON or Autoprint OFF x Viewing the plot for the current series of readings Press pori on the keypad to enter the PLOT TRACE screen For more details regarding this screen see the User s Manual Battery charging O VO Connect the lead from the Mains adaptor Charger to the mains connector at the back of the TorqueStar Opta see Rear View overleaf and connect the mains adaptor to an AC mains supply The adaptor can be used for direct power from the mains or to charge the internal battery It has an automatic cut off to prevent overcharging Quick Store Mode O aS The QUICK STORE mode is accessible by selecting the OTHER MODES option from the Main Menu and then selecting the QUICK STORE icon It works with PEAK PULSE or CLICK and is similar to the Quick Reading but stores up to 200 readings for analysis and assessment etc For more information on QUICK STORE see the User s
2. Crane TorqueStar 07a Quick Start Guide Man 890 01 SCREEN CONNECTORS rear of machine Mains charger Transducer cable KEYPAD attaches here attaches here PC printer cable attaches here SECURING LUGS REAR VIEW SHOWING CONNECTORS Press the ON button on the keypad The MAIN MENU screen now appears Menu and To change the Language level number select here and press the green Enter Button No users logged in cross To change the Power disappears options select here and when users press the green Enter Button are logged in Track Z ul Click Force Press TA to change the TIME DATE Press to enter the TOOLS menu or the Date FORMAT Selecting the Quick Measure Mode Use the ARROW buttons A to move The selected QUICK READING Mode screen will now appear on the around the screen Icons until the required display You are now ready to connect a transducer and take a reading mode icon is highlighted and press the green ENTER button B to select NOTE Before entering the QUICK READING Mode make sure a suitable transducer is connected to the TorqueStar Opta otherwise an B error message will be displayed on the screen Attach the cable from the transducer to the 25 way D connector on the back of the TorqueStar see REAR VIEW above Issue 2a June 2012 Taking a Reading TYPICAL SCREEN With the transducer connected to the Torquestar Opta AE Quick Reading 02 03 apply
3. Manual To switch off the TorqueStar Opta From the Main Menu screen highlight the Power Menu Icon using the arrow keys and press the green ENTER button From within the POWER OPTIONS screen press ES on the keypad to switch off the Opta
4. torque to the transducer using a suitable tool and Number of pulses 9 a D 108 Total time torque is applied observe the reading on the screen This example Pulse Mode only shows a Pulse Mode screen The display will show the amount of torque applied in the chosen Units of Torque reading Measure Nm shown here the type of transducer and the serial number The information on the screen will Siecton vary according to the type of Measure mode selected The top of the screen shows the mode selected both Transducer as text and an icon The direction of the applied torque auau is shown if applicable and the number of pulses if in Pulse mode NOTE Press C on the keypad to return to the previous menu level Changing the Settings To change the settings for the chosen Quick Reading mode press on the keypad to select the Settings icon T The screen will Press the corresponding number on the keypad to access the features displayed on the bottom row of the screen now display the Settings Menu and the user can change some or all the following settings UTA ID Units of Measurement Direction Cycle End Time Frequency Response Torque Threshold Second Parameter and Second Parameter Threshold if applicable The options available will vary according to the chosen measure mode Use the arrow keys to highlight the required parameter and press the green ENTER button Use the UP and DOWN arrow keys to change the setting and press
Download Pdf Manuals
Related Search
Related Contents
スペースレールに関するよくある質問 施工編 ULTIMEG 2002 取扱説明書ダウンロード TMC TRAILER AXLE SERVICE MANUAL DRUM BRAKE AXLES PresenterPLUS to view pdf - AdvanceDesign 取 扱 説 明 書 - OptoSigma Global Top FULL BLACK TFT Copyright © All rights reserved.
Failed to retrieve file