Home

Ilumipod 18 IP Optic Series User Manual

image

Contents

1. W DMX Values ARC 1 Red o 000 lt gt 255 0 100 2 000 lt gt 255 0 100 3 Blue 000 lt 25510 100 ARC 1 D Channel Function Value _ Percent Setting 1 Dimmer 00 amp 25510 100 2 Rd 000 amp 255 0 100 3 _ Green 000 amp 255 0 100 4 Blue 000 gt 25510 100 ARC FULL Channel Function Value Percent Setting 1 Dimmer L000 255 0 100 2 Rd 000 lt gt 255 0 100 3 Green 00 amp 255 0 100 4 Bu 000 lt gt 255 0 100 No Function Red 100 Green Up Blue 0 Red Down Green 100 Blue 0 Red 0 Green 100 Blue Up Red 0 Green Down Blue 100 Red Up Green 0 Blue 100 Red 100 Green 0 Blue Down Red 100 Green Up Blue Up Red Down Green Down Blue 100 Red 100 Green 100 Blue 100 5 Color Macro White Balance 201 lt gt 205 White 1 3 200 K 206 210 White 2 3 400 K 211 215 White 3 4 200 K 216 220 White 4 4 900 K 221 lt gt 225 White 5 5 600 K 226 230 White 6 5 900 K 231 lt gt 235 White 7 6 500 K 236 240 White 8 7 200 K 241 245 White 9 8 000 K 246 250 White 10 8 500 K 251 lt gt 255 White 11 10 000 K 000 lt gt 004 No Function 000 lt gt 009 Dimmer is set by Ilumicode 010 lt gt 029 OFF Dimmer is linear 7 Dimming Speed 030 lt gt 069 DIM1 Fastest dimmer curve 070 lt gt 129 DIM2 130 lt gt 189 DIM3 190 255 DIM4 Slowest dimmer curve llumipod 18 IP Optic Series User Manual Rev 08
2. Connectors Cord plug Type LED Color Cool White Warm White Parameter Illuminance O 5m Beam angle Field angle Max External Temperature 104 F 40 C I O Connectors llumipod 18 IP 30 VW 11018010 llumipod 18 IP Optic Series User Manual Rev 08 Width 5 9 in 150 mm Note Dimensions in inches rounded to the nearest decimal digit Range 100 240 V 50 60 Hz 120 V 60 Hz 30 W 0 4 A 0 8 A Input Open Wires Open Wires Power 1 W Quantity 6 12 302 Optics 57 lux 34 79 61 79 Cooling System Convection Connector Type Sockets Optional Ilumicode 44444001 Height 9 6 in 245 mm Technical Information Weight 6 lbs 2 6 kg Voltage Selection Auto ranging 230 V 50 Hz 30 W 0 4 A 0 6 A Output Open Wires Open Wires Lifespan 50 000 hours Current 350 mA 350 mA Channel Range 1 2 or 3 CONFORMES TO UL STD 1573 CERTIFIED 10 US cSASTD 022 2 Ne 166 3144482 25 Technical Information ILUMINARC ILUMINARCO 5200 NW 108th Avenue Sunrise FL 33351 U S A Tel 954 923 3680 www iluminarc com i n llumipod 18 IP Optic Series User Manual Rev 08 August 2011 m
3. L4 although non critical information indicates O important installation or configuration information Failure to comply with this information may prevent the product from functioning correctly This icon This icon indicates critical installation configuration or operation information Failure to comply with this information may render the product partially or completely inoperative damage third party equipment or cause harm to the user The term DMX used throughout this document refers to the USITT DMX512 A transmission protocol llumipod 18 IP Optic Series User Manual Rev 08 What Is in the Box e One Ilumipod 18 IP Optic product RGB or VW e Warranty Card e Quick Reference Guide Unpacking Instructions Immediately upon receiving a product from ILUMINARC carefully unpack the carton Check the contents of the box to ensure that all parts are included and in good condition If any part appears damaged from shipping or if the carton shows signs of mishandling see the Claims section in the Technical Information chapter Text Conventions Convention Meaning 1 512 A range of values in the text 50 60 A set of mutually exclusive values in the text ILUMICON UM The name of another publication or manual lt SET gt A button on the products control panel Settings A product function or a menu option MENU gt Settings A sequence of menu options 1 10 A range of menu values from which t
4. Select the REMOTE personality ILUMICON controller Static Color Only for 18 IP OPTIC RGB Go to STATIC Select a color RED GREN or BLUE Select a color value 000 255 Select STRB Select a strobe frequency 0 20 A oi ck o J Only for 18 IP OPTIC VW 1 Goto STATIC 2 Select a color COOL or WARM 3 Select a color value 000 255 Color Calibration WHITE 1 11 define the Only for 18 IP OPTIC RGB white color sown when 1 Goto CALIB selecting a value 201 255 in 2 Select a white color WHITE 1 11 or RGBTOW ea s 3 Select an RGB color RED GREN or BLUE 4 Select a color value 0 255 RGBTOW defines the 5 Repeat steps 3 and 4 for the other RGB colors to obtain a white color white color shown reo COLOR 6 Repeat steps 2 to 5 for the other white colors value is set to RGBTOW Color Only for 18 IP OPTIC RGB 1 Goto SETTINGS gt COLOR 2 Select the color method OFF RGBTOW or UC Color Description When the RGB faders are all at 255 the output is at its maximum When the RGB faders are all at 255 the output is the selected white color see Color Calibration When the RGB faders are all at 255 the output matches the same color output of previous versions of this product OFF RGBTOW UC Reset 1 Goto SETTINGS gt RESET TO FACTORY SETTINGS 2 Select an option YES NO MI Mumipod 18 IP Optic Series User Manual Rev 08 i n mi
5. strives to hold its LED manufacturers to the highest standards of binning to optimize consistency in output from product to product However the availability of a single bin cannot be guaranteed With that in mind ILUMINARC has developed a rigorous control system to seek the best achievable consistency in color and output Color Rendering Index CRI CRI is an industry standard method to compare properties of different types of light sources There are known limitations and inconsistencies related to CRI Results may vary depending on the environmental factors involved For this reason the US Department of Energy DOE states that CRI should be considered as one point of reference among others in evaluating white LED products and systems The following is an excerpt of recommendations from the DOE 1 Identify the visual tasks to be performed under the light source If color fidelity under different light sources is critically important for example in a space where color or fabric comparisons are made under both daylight and electric lighting CRI values may be a useful metric for rating LED products 2 CRI may be compared only for light sources of equal CCT This applies to all light sources not only to LEDs Also differences in CRI values of less than five points are not significant e g light sources with 80 and 84 CRI are essentially the same 3 If color appearance is more important than color fidelity do not exclude white l
6. NAD AA 11 SpectraWhite Functions Menu Map 11 RGB Functions Menu M j SO 12 ROG AMM e a m o r d g9a 13 AS O A dite 13 DMA Stating Adir ii A da a ki 13 IMM eS 13 LUMICON Controla lona 14 anda OF a eo iaai ia A doo i O E A 14 Color calibrato Nesca E E 14 CONOR alias 14 pio T E pe A eee er ante 14 PINS een meme e o e EET e er e T 15 PNG Mr ae mn neb m mane nj a o m e e a DEN mene 15 ARG D a esos 15 a COR 15 NAN a ad ten Lio Nae whi et tn SS A Neca i 16 ee 16 A O pt een reer nt Sept 16 llumipod 18 IP Optic Series User Manual Rev 08 i Table of Contents ILUMINARC 5 Technical Information zi ganja sevencageredbstagusedseeevedvasstudedcevaieaveteevenacaets 17 POGUE Maintenance aan an dali een E ani A 17 ProdUC RODAS sesiis a e vr o pv e o 17 Troubles No ind GUJE A e e a 18 mp ole TAIN ett asi e ovo E e a osla dij 19 Ma DIBIT Ei gr m mamom rem o mrem nero rm emo 22 LEDS o anna a ja ei AT ed o ao A Ed toa 22 BEBE EU IMM le ie arent opa a in a a op O a i Vi 22 Color Rendering Index CRI sli ik yek didas 22 Returns Procedure 20 as en na ik aot e ad et di ote eal 23 Glai A Sd Maca A s E 23 OAC LS mapa o E E a E do et dt e dn 23 Technical SPe INCANONS ia 24 llumipod 18 IP Optic RGB kereke aaa 24 llumipod 18 IP Optic VW i kk keke eke kek keke kek k reke k kek kk k k rek 25 ii llumipod 18 IP Optic Series User Manual Rev 08 Introduction 1 Introduction This icon indicates useful
7. Source Photo Optic Thermal DMX Ordering 24 Length 5 7 in 145 mm Power Supply Type Switching internal Parameter Consumption Inrush current Power I O Connectors Cord plug Type LED Color Red Green Blue Parameter Illuminance O 5m Beam angle Field angle Max External Temperature 104 F 40 C I O Connectors Open Wire llumipod 18 IP Optic RGB 5 9 in 150 mm Note Dimensions in inches rounded to the nearest decimal digit Range 100 240 V 50 60 Hz 120 V 60 Hz 25 W 0 4 A 0 3 A Input Open Wires Open Wires Power 1 W Quantity 6 6 6 30 Optics 66 lux 26 4 53 3 Cooling System Convection Connector Type Sockets 15 Optics 11018001 9 6 in 245 mm Weight 6 lbs 2 6 kg Voltage Selection Auto ranging 230 V 50 Hz 26 W 0 3 A 0 3 A Output Open Wires Open Wires Lifespan 50 000 hours Current 350 mA 350 mA 350 mA 15 Optics 238 lux 12 6 26 27 Channel Range 1 3 4 or 7 302 Optics 11018004 CONFORMS TO UL STD 1573 CERTIFIED TO S CSASTO 022 2 No 166 9144482 Ilumipod 18 IP Optic Series User Manual Rev 08 LUMI MI Ft Tz N pan H llumipod 18 IP Optic VW Dimensions and Weight Electrical Light Source Photo Optic Thermal DMX Ordering Length 5 7 in 145 mm Power Supply Type Switching internal Parameter Consumption Inrush current Power I O
8. VAR La Technical Information Technical Information LUN VW 1_ Warm White 000 lt gt 255 0 100 2 Cool White 000 lt 25510 100 VW D 1 Dimmer 000 amp 2550 100 2 Warm White 000 amp 2550 100 3 Cool White 000 gt 25510 100 SOLID 1 Dimmer 000 lt 25510 100 16 Ilumipod 18 IP Optic Series User Manual Rev 08 k La Technical Information 5 Technical Information Always dry the external optics and glass surfaces carefully after cleaning them If you still experience technical problems after trying the solutions in the Troubleshooting Table contact ILUMINARCO Technical Support Product Maintenance To maintain optimum performance and minimize wear the user should clean the products frequently Usage and environment are contributing factors in determining the cleaning frequency As a rule the user should clean the products at least twice a month Dust build up reduces light output performance and can cause overheating This can lead to reduced light source life and increased mechanical wear For products containing external optical lenses the user should clean them periodically to optimize light output The cleaning frequency depends on the environment in which the product operates Damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics To clean a product follow the below recommendations e Disconnect the product from
9. modes Hasna peo 1 channel Dimmer hante make se fo 2 channel Warm white cool white use the right product 3 channel Warm white cool white dimmer order code for the desired e 18x 1 W 350 mA Warm White and Cool White LEDs lens angle e Installed non changeable optical system 30 lenses Product order code 11018010 llumipod 18 IP Optic RGB Features e Operating modes 3 channel RGB control 4 channel RGB dimmer 7 channel RGB dimmer macro strobe dimming speed e High power 1 W 350 mA Red Green and Blue LEDs e lumicode compatible e Blackout static dimmer strobe pulse e Installed non changeable optical system 15 lenses Product order code 11018001 30 lenses Product order code 11018004 llumipod 18 IP Optic Series User Manual Rev 08 3 Installation ll HN WNARHL Product Overview Cable tie location Gore Valve Power In Mounting Bracket Safety cable Front of attachment product Bracket Adjustment 4 llumipod 18 IP Optic Series User Manual Rev 08 ILUMINARC Installation Product Dimensions llumipod 18 IP Optic Series User Manual Rev 08 5 Installation 3 Installation Always connect A the llumipod 18 IP Optic Series to a protected circuit with an appropriate electrical ground to avoid the risk of electrocution or fire Never connect A the llumipod 18 IP Optic Series to a rheostat variable resistor or dimmer circuit even if the rheostat or d
10. power e Wait until the product is cold e Clean all external glass optics and glass surfaces with a mild solution of glass cleaner or isopropyl alcohol and a soft lint free cotton cloth or a lens cleaning tissue e Clean all plastic surfaces including LED lenses with mild soapy water and a soft lint free cotton cloth You could also use a lens cleaning tissue e Apply the solution directly to the cloth or tissue and drag any dirt and grime to the outside of the lens e Gently polish the external glass surfaces until they are free of haze and lint Product Repairs ILUMINARC strongly advises you against attempting any repairs to this product unless you are an authorized ILUMINARC technician ILUMINARC presents the information contained in the Troubleshooting Table as a guide only In most cases opening the product s housing will invalidate its warranty unless there is a written indication on the contrary llumipod 18 IP Optic Series User Manual Rev 08 17 Technical Information ILUMINA Troubleshooting Guide Symptom Cause s Action s Dimmer fader set to 0 Increase the value of the dimmer channel All color faders set to 0 Increase the value of the color channels All colors in STATIC are set to 0 Increase the values of the colors Product does not light up Unit is being configured with Ilumicode Complete the configuration process No power Verify external power circuit and wiring Faulty i
11. with the Ilumipod 18 IP Optic Series product The figure below illustrates how to connect the ILUMICON controller to the Ilumipod 18 IP Optic Series Py 1 ower To _ other fixtures ILUMICOM Controller llumipod 18 IP Optic Series User Manual Rev 08 ILUMINARC Installation llumicode To assign The Ilumipod 18 IP uses the Ilumicode addresser for configuration purposes The diagram 1 ww na below shows how to connect the Ilumicode to this product addresses to each product you Note that this connection will control multiple products at the same time all having the must connect the same DMX address Ilumicode controller to each product individually ILUMINARCO suggests that you connect no more than 20 products To in this mode and keep the total distance to less than other fixtures 60 m 197 ft Otherwise you might need to use an optically isolated signal amplifier ILUMICODE 1 Gnd 1 Gnd Black clip Addresser 2 Data 2 Data Green clip 3 Data 3 Data Red clip DMX Output Signal Connector llumipod 18 IP Optic Series User Manual Rev 08 9 Installation A Make sure to mount this product away from any flammable material as indicated in the Safety Notes LUMINARC Mounting Before mounting this product read and follow the safety recommendations indicated in the Safety Notes section page 2 of this manual Orientation Always mount this product in a safe posi
12. 0 Lamp 6 RED 6 GREEN 6 BLUE 1 667 1105 Lamp Output 1 lamp s rated Lumens lamp 690 prem Max Candela 4 971 8 at Horizontal 0 Vertical 0 gi Input Wattage 24 6 CD 0 a Luminous Opening Point 833 By Test 2009430RGB U Test Lab lluminarc R amp D Optics Laboratory Photometry Type B 2 500 ep CIE Class Direct 3 333 Cutoff Class Full Cutoff 4 167 ene WR VO 10 20 305 4 0 H 1 180 H BB 30H 270 H m 45 H Flood Summary Efficiency Lumens Horizontal Spread Vertical Spread Field 10 48 7 335 9 53 3 53 3 Beam 50 23 9 164 6 26 4 26 3 Total 58 3 402 2 Tiluminance at a Distance Center Beam FC Beam Width LO 153 24 fc LAR 1 aft s 38 31 fe ia 2 8 5 0 30 17 03 fe 42h 42h o 9 58 fe 5 6 5 6 6 13 fc 7 oft 7 0 4 26 fe aaf B 5ft 10 0 M Vert Spread 26 3 BB Horiz Spread 25 4 Photometics Pro 1 3 2 copyright 2003 2008 by jSolutions Inc Reported data calculated from manufacturer s data file based on IES recommended methods 20 llumipod 18 IP Optic Series User Manual Rev 08 ILUMINARC Filename Ilumipod 18 IP Optic 30 VW 100 ALL Manufacturer ILUMINARC Luminaire Ilumipod 18 IP Optic 30 VW Lamp 12 Warm White 6 Cool White Lamp Output 1 lamp s rated Lumens lamp 1380 Max Candela 1 237 1 at Horizontal 90 Vertical 5 Input Wattage 26 9 Luminous Opening Point Test 2009 ALL Test Lab lluminarc R amp D Optics Laboratory Photometry Type B CIE Class Direct Cutoff Class Full
13. Cutoff Filename Ilumipod 18 IP Optic 30 VW 100 ALL Technical Information Polar Candela Distribution na 180 170 160 150 140 1 063 650 33 1 083 1 300 MW 0H ijel M 90 H 270 H Flood Summary Efficiency Lumens Horizontal Spread Vertical Spread Va 10 205 3P 40 Field 10 31 8 438 4 61 8 61 5 Beam 50 18 6 257 1 34 9 34 5 Total 36 6 505 3 luminance at a Distance Center Beam FC Beam Width Lh 131 79 fe 1 9 1 9 Oh 32 95 fe 3 7h LAR an 14 64 fc 5 6 53 a 8 24 fe ZAR 35h wok 5 27 fe q 3ft 9 4 io 3 66 fe 11 25 11 3 Vert Spread 34 5 BHoriz Spread 34 57 Photometics Pro 1 3 2 copyright 2003 2008 by jSolutions Inc Reported data calculated from manufacturer s data file based on IES recommended methods llumipod 18 IP Optic Series User Manual Rev 08 21 Technical Information LU IVUINARL 22 LED Disclaimer LED Life ILUMINARC rates LED lifetime based on lumen depreciation of 70 of the original output with data provided by the manufacturer of the LED Data from the manufacturer of the LED are not independently verified or measured by ILUMINARC When the product is Operating in optimal environmental conditions the LED lifetime is rated to be 50 000 to 70 000 hours by the LED manufacturer LED Binning LED manufacturers sort LEDs into bins based on variances in color output intensity and the frequency at which the semiconductor operates ILUMINARC
14. Ej RGB Functions Menu Map When you scroll through the menu levels you Main Level will see many of them that do not DMX correspond with this menu map These levels are for SpectraWhite products ly Say PERSON CALIB DIMMER If you scroll after STRB you will see the AMBE STATIC COOL and WARM colors Disreguard them as they do not work with the RGB products SETTINGS 1 Programming Levels Description 001 512 N A Sets the DMX starting address ARC 1 3 channel RGB control ARC 1 D 4 channel RGB control dimmer 7 channel RGB control dimmer color macro strobe dimmer speed Allows using the ILUMICON unit SOLID 1 channel dimmer ARC FULL N A WHITE 1 11 RED Determines the white balance for the color m z m macros O TT NEI hen RGBTOW RGBTOW BLUE l etermines the white balance when 1s act ve OFF Dimmer work in linear mode DIM 1 DIM 2 N A Dimmer works in non linear mode from fast to DIM 3 slow DIM 4 RED GREN j 0 255 Configures the static color and effect BLUE STRB OFF Maximum output unbalanced white White output is as per CALIB gt RGBTOW COLOR A settings UC Output matches that of product s previous versions RESET NO YES Resets unit to factory default settings Ilumipod 18 IP Optic Series User Manual Rev 08 ii mim T zi m i i h F L Y a li LI F Li a j I NAN Technical information Programming Make sure to ne Lu Carry out all the programming proce
15. Ilumipod 18 IP Optic Series User Manual e llumipod 18 IP Optic RGB e Ilumipod 18 IP Optic VW Edition Notes ri ee F 4 ra hl Bi Ta P k BI 4 F bj y r j ji IS i _ kh W I EB u r Edition Notes The Ilumipod 18 IP Optic Series User Manual Rev 08 covers the description safety precautions installation programming operation and maintenance of all the Ilumipod 18 IP Optic Series ILUMINARC released this edition of the Ilumipod 18 IP Optic Series User Manual Rev 08 in August 2011 Trademarks The ILUMINARC logo the ILUMINARCO name and all other trademarks in this document related to services or products by ILUMINARC are trademarks owned or licensed by ILUMINARC its affiliates or subsidiaries Any other product names logos brands company names or trademarks featured or referred to within this document are the property of their respective trademark holders Copyright Notice The entire content of this document except where applicable and unless otherwise noted is solely owned by ILUMINARC a wholly owned trademark of CHAUVET amp Sons Inc Copyright 2011 ILUMINARC All rights reserved Electronically published by ILUMINARC in the United States of America Manual Usage ILUMINARC authorizes its customers to download and print this manual for professional information purposes only ILUMINARC expressly prohibits the usage copy storage distribution modification or pr
16. al Rev 08 J M I M mm ae W J FA y Ta ble of Conte nts Table of Contents 1 TEE OIG ilo tada he sncf clean 1 Whal NS WINE BOX int e adja kre dx N njoj 1 INPackind IASTUCUONS o o tsat nik Soo has osa 1 TeX CONVENTO Sica 1 Sale Notes ita 2 Personal iras 2 Mounungsana stato cado 2 OW EI NOW ad ecos ee clas 2 OPE ae 2 2 PIOQUCE DESCHIPUON iii dan 3 COMMON Feios in o in pd tee tte 3 llumipod 18 IP Optic SpectraWhite Features ooooocccnccccconnonccnnncnnonnnoncnnncnononannnenoncnnnonanos 3 ll mipod 18 1P Optic RGB Features is eda etched costed tad r rg 3 gun lon Da DD A non ida 4 ALOE DIMENSIONS SSSR r a ds 5 3 MENS URN ALOUD ari 6 AG POW GI SVDDDrrwrvvC rh h o r r 6 Input Voltage and Frequency sise 6 Power GONSUIMPION aie KA kya Ker daca ah e ee dje zas Le ee cl cu 6 moje WINO pe ali 6 Tela ls ka i ra le pape rme m ar eve ar e pm re re 6 v0n ANN ae PP trt a saan ab A S LANA 6 POWEFD ISMIDUNOM HSE ol iros 7 SIONAVDISMPOHNON ia i KE ken osing i n 7 CONTO ha mr e a rone des 8 ENSGON TO NE o onaj a E BA a 8 IEUMICON mnm nm nom me ne a a Pa 8 Tn me e rene 9 Ml el pii qe peer e e m rem o e e jn o 10 A mnm mn m e e ve mea 10 m e e Tale PS a Ne e o E e er N 10 FOS CU TT ii A o S o qe 10 A OPETaANON cai Ski i S e A i 11 A m mr ne m e e vr na 11 lEmicode Panel ESEfIPUOK kc dt sato atol nn M anti st data 11 Menu MAD LA Kan A saray n VERS
17. do not submerge deeper than 1m for more than 30 thirty minutes Make sure there are no flammable materials close to this product while operating When hanging this product always secure it to a fastening device using a safety cable not provided Power and Wiring Always make sure that you are connecting this product to the proper voltage as per the specifications in this manual or on the product s sticker Never connect this product to a dimmer pack Make sure that the power input cable is not cracked crimped or damaged Operation The maximum ambient temperature Ta is 104 F 40 Do not operate this product at a higher temperature In case of a serious operating problem stop using this product immediately llumipod 18 IP Optic Series User Manual Rev 08 2 Product Description The Ilumipod 18 IP Optic Series includes two products Humipod 18 IP Optic RGB and Ilumipod 18 IP Optic VW Common Features 4 e aan ger e Remotely addressable DMX 512 LED wash light configuration and programming e P67 ingress protection features these two products share the e P67 stainless steel gland nuts for cable entry same dimensions as well e Humidity controlling gore valve as the installation wiring and troubleshooting e Cast aluminum housing procedures e ILUMICON compatible e Five distinct dimming curves llumipod 18 IP Optic VW SpectraWhite Features The lenses in 4 these two e Operating
18. dures indicated below from the control panel Refer to the option Otherwise the Menu Map in pages 11 and 12 to learn how the menu options relate to each other des ly Pan Use lt ENTER gt and lt MENU gt to change levels in the Menu Map This is equivalent to move ihe e display l right and left respectively Use lt UP gt and lt DOWN gt to move vertically within the Menu Map will show SEND options DMX Personality 1 Goto PERSON and select any DMX personality that matches the product with which you are working ignore any other options 18 IP RGB 18 IP VW ARCI ARC D ARC FULL SOLID SOLID VW VW D 2 Make sure to rearrange the DMX addresses of all products in the current DMX universe to avoid address overlapping DMX Starting Address All Ilumipod 18 IP Optic Series The DMX Starting Adaress setting E works with all but 1 Goto DMX ine REMOTE 2 Selecta starting DMX address 001 512 personality Dimmer All Ilumipod 18 IP Optic Series 1 Goto DIMMER 2 Select a dimmer curve OFF or DIM1 4 DIMMER Description OFF Dimmer curve is linear with fader DIM1 Non linear fastest DIM2 Non linear fast DIM3 Non linear slow DIM4 Non linear slowest llumipod 18 IP Optic Series User Manual Rev 08 13 i M im Technical Information ILUN L ri i ha ri a u il m a Fon ILUMICON Control Only for 18 IP OPTIC RGB Do not connect O any other 1 Goto PERSON ll h Us n 2
19. e e Your address e Your phone number e The RMA e A brief description of the problem Be sure to pack the product properly Any shipping damage resulting from inadequate packaging will be the customer s responsibility As a suggestion proper UPS packing or double boxing is always a safe method to use Claims The carrier is responsible for any damage incurred during shipping Therefore if the received merchandise appears to have damages caused during shipping the customer must submit the damage report and any related claims with the carrier not ILUMINARC The customer must submit the report upon reception of the damaged merchandise Failure to do so in a timely manner may invalidate the customer s claim with the carrier For other issues such as missing components or parts damage not related to shipping or concealed damage the customer must make claims to ILUMINARC within seven 7 days of receiving the merchandise Contact Us World Wide General Information ILUMINARC 5200 NW 108th Avenue Sunrise FL 33351 Voice 954 923 3680 Fax 954 929 5571 Email info iluminarc com Customer Support Voice 954 923 3680 ext 4000 Fax 954 756 8015 Email tech iluminarc com World Wide Web www iluminarc com llumipod 18 IP Optic Series User Manual Rev 08 m La Technical Information 23 Technical Information Technical Specifications Ilumipod 18 IP Optic RGB Dimensions and Weight Electrical Light
20. e EH Pin 4 Data Cut green mi Pin 5 Data Out red i Conduit box out Installation If you have not configured the DMX starting address and DMX mode for each product they will all use their default values This means that all products will operate in unison Refer to the Operation chapter to learn how to enable the llumipod 18 IP Optic RGB to operate with the ILUMICON controller ILUMINARC Controllers The products in the Humipod 18 IP Optic Series can operate with a standard DMX controller or the Ilumicode controller The sections below will show you how to connect these products to the corresponding controllers The instructions to operate these products with each of the above controllers are in the Operation chapter of this manual DMX Controller The Ilumipod 18 IP Optic Series can work with a standard DMX controller The channel assignments will depend on the chosen personality see the corresponding Menu Map on pages Iland 12 and the DMX address assigned to each product see Programming on page 13 The figure below illustrates how to connect the DMX controller to the Humipod 18 IP Optic Series products Power To other fixtures FE OOOOOCOO 00000015 DMX 512 A Controller JODOOO ILUMICON The Ilumipod 18 IP Optic RGB can also work with the ILUMICON controller instead of a standard DMX controller Please refer to the ILUMICON User Manual to learn how to use this controller
21. elected function Navigates upwards through the menu list and increases lt UP gt i E the numeric value when in a function Navigates downwards through the menu list and lt DOWN gt 3 EA decreases the numeric value when in a function Turns the unit on The unit will turn off automaticall lt POWER gt gt after 30 seconds of inactivity Menu Map E When you scroll The products in the Ilumipod 18 IP Optic Series have distinct menu maps based on the colors ee son they produce whether RGB or White The Ilumicode addresser controls the functions for both will see many of types of products them that do not correspond with this menu SpectraWhite Functions Menu Map map These levels are for RGB products only This menu map shows you which parameters of the Ilumicode controller correspond to the Ilumipod 18 IP Optic Series VW product DIMMER DIM 2 N A Dimmer works in non linear mode from fast to DIM 3 slow DIM 4 COOL WARM Main Level Programming Levels Description DMX 001 512 N A Sets the DMX starting address If roll after STRB you i 3 channel SpectraWhite control see the RED PERSON N A 4 channel SpectraWhite control dimmer GREN BLUE and AMBE colors SOLID 1 channel dimmer Disreguard them as they Dimmer work in linear mode do not work with the VW DIM 1 Dm2 STATIC 0 255 Configures the static color and effect llumipod 18 IP Optic Series User Manual Rev 08 11 Technical Information
22. ight LEDs solely on the basis of relatively low CRI values Some LED products with CRIs as low as 25 still produce visually pleasing white light 4 Evaluate LED systems in person and if possible on site when color fidelity or color appearance are important issues Source DOE publication PNNL SA 56891 January 2008 Ilumipod 18 IP Optic Series User Manual Rev 08 r A n g i d L r L Fo DO NOT write the RMA directly on the box Instead write it on a properly affixed label ILUMINARC reserves the right to use its own discretion to repair or replace returned product s Always keep the original box and all packaging material as you will need those to ship the unit back to ILUMINARCO i i EFR In B AM A u y 4 Returns Procedure The user must send the merchandise prepaid in the original box and with its original packing and accessories ILUMINARC will not issue call tags Call ILUMINARC and request a Return Merchandise Authorization Number RMA before shipping the product Be prepared to provide the model number serial number and a brief description of the cause for the return The user must clearly label the package with a Return Merchandise Authorization Number RMA ILUMINARC will refuse any product returned without an RMA Once you receive the RMA please include the following information on a piece of paper inside the box e Your nam
23. immer channel serves only as a 0 to 100 switch Make sure to connect the 18 IP Optic Series product to a power line with the proper voltage and frequency as per the specifications in this manual or on the product s sticker The listed current rating indicates the maximum current draw during normal operation The signal cable j must match or exceed the electrical characteristics of the Belden 9841 cable for EIA RS 485 applications You may also use CAT5 be or CAT6 LAN cable If you choose to j bury the power or signal distribution boxes make sure that they are IP67 rated or greater AC Power Input Voltage and Frequency Power Consumption Signal Wiring External Wiring The products in the Ilumipod 18 IP Optic Series have an auto ranging power supply with an input voltage range of 100 240 VAC 50 60 Hz To determine the power requirements for the Ilumipod 18 IP Optic Series see the label affixed to the side of the product Alternatively you may refer to the corresponding specifications chart in the Technical Information chapter of this manual The listed current rating indicates the maximum current draw during normal operation Power Wiring To provide AC power for any of the Ilumipod 18 IP Optic Series you can connect the bare ended IP67 rated power cable from the product to an IP67 rated power connector or use an IP67 rated junction box In this case make sure to use IP67 rated cond
24. inting of this manual or its content for any other purpose without its written consent Document Printing For better results print this document in color on letter size paper 8 5 x 11 inches double sided If using A4 paper 210 x 297 mm configure your printer to scale the content of this document to A4 paper Intended Audience Any person in charge of installing operating and or maintaining the Ilumipod 18 IP Optic Series should read the Guide that shipped with it and this manual in their entirety before installing operating or maintaining this product Disclaimer ILUMINARC believes that the information contained in this manual is accurate in all respects However ILUMINARC assumes no responsibility for any error or omissions in this document ILUMINARC reserves the right to revise this document and to make changes from time to time in the content hereof without obligation of ILUMINARC to notify any person or company of such revision or changes This does not constitute in any way a commitment by ILUMINARC to make such changes ILUMINARC may issue a revision of this manual or a new edition of it to incorporate such changes Document Revision The Ilumipod 18 IP Optic Series User Manual Rev 08 supersedes all previous versions of this manual Please discard any older versions of this manual you may have whether in printed or electronic format and replace them with this version llumipod 18 IP Optic Series User Manu
25. minaire Cat 11018001 Lamp 6 RED 6 GREEN 6 BLUE 3 333 1 667 Lamp Output 1 lamp s rated Lumens lamp 690 Max Candela 4 971 8 at Horizontal 0 Vertical 0 Input Wattage 24 6 Luminous Opening Point Test 2009430RGB 833 CD 0 833 1 667 Test Lab lluminarc R amp D Optics Laboratory Photometry Type B CIE Class Direct Cutoff Class Full Cutoff 3 0 t zh 12 08 15 0 18 0A Vert Spread 12 7 3 333 4 167 5 000 Technical Information Polar Candela Distribution E H m 90 H 180 170 1607 1505 1407 VA O 10 20 30 49 180 H 270 H M 45H E L Flood Summary Efficiency Lumens Horizontal Spread Vertical Spread 39 7 273 8 25 6 Field 10 Beam 50 Total 552 42 fc 138 11 fc 61 38 fe 34 53 fe 22 10 fe 15 35 fe Photometics Pro 1 3 2 copyright 2003 2008 by jSolutions Inc Reported data calculated from manufacturer s data file based on IES recommended methods llumipod 18 IP Optic Series User Manual Rev 08 17 6 121 3 12 5 57 2 394 6 Illuminance at a Distance Center Beam FC Beam Width 0 7 0 7 1 3 1 38 2 0 2 0 276 26H 3 3ft 33h 4 0ft 3 9ft WHoriz Spread 12 5 Technical Information ILUMINARC Filename Ilumipod 18IP Optic 30RGB Polar Candela Distribution RGB_IESNA2002 ci 180 170 160 150 140 Manufacturer ILUMINARC E 4 167 1392 Luminaire ILUMIPOD 18IP OPTIC RGB 30 DEGREE 3 333 nm Luminaire Cat 11018001 gt 50
26. nternal power supply Return for service to Iluminarc Faulty main control board Return for service to Iluminarc Faulty LED One LEDs does not work Faulty LED module Faulty LED driver Return for service to Iluminarc The wrong LEDs light up when Change the personality using DMX Change the DMX address Circuit breaker fuse keeps Excessive circuit load Check total load on electrical circuit tripping blowing Check for a short in the electrical wiring Change DMX address Return for service to Iluminarc amp Damaged DMX cables Check DMX cables Check polarity switch settings on the newe does not respond to Wrong polarity on the controller cw a gt 8 Loose DMX cables Check cable connections Faulty DMX interface Return for service to Iluminarc Faulty Display Main board Non DMX compliant cables Use only DMX compatible cables Unstable control signals Install terminator as suggested Install an optically coupled DMX splitter LONE CAD NS SO A ae right after the product with the strong signal DMX signal problems Install an optically coupled DMX splitter Too many products after unit 432 or before Keep DMX cables separated from power Interference from AC wires cables or fluorescent black lights 18 Ilumipod 18 IP Optic Series User Manual Rev 08 ILUMINARC Photometrics Filename llumipod 18IP Optic 15RGB RGB_IESNA2002 Manufacturer ILUMINARC 5 000 4 167 Luminaire ILUMIPOD 18IP OPTIC RGB 15 DEGREE Lu
27. o choose in a menu Yes No A set of two mutually exclusive menu options in a menu ON A unique value to enter or select in a menu Introduction A There are no user serviceable parts inside this product Any reference to servicing it you may find from now on in this User Manual will only apply to properly ILUMINARCO certified technicians Do not open the housing or attempt any repairs unless you are Certified to do so Please refer to all O applicable local codes and regulations for the proper installation of this product Keep this manual Ei for future consultation If you sell this product to another user make sure that they also receive this manual In the unlikely O event that your Ilumipod 18 IP Optic Series may require service please contaci ILUMINARCE Technical Support Safety Notes Please read all the following safety notes carefully because they include important information on how to install use and maintain this product safely Personal Safety Avoid direct eye exposure to the light source while the product is on Always disconnect this product from its power source before servicing Always connect this product to a grounded circuit to avoid the risk of electrocution Do not touch this product s housing when operating because it may be very hot Mounting and Installation The Ilumipod 18 IP Optic Series are for outdoor use and can work while submerged in up to 1 m of water 1P67 However
28. tion making sure there is adequate room around it for ventilation configuration and maintenance Rigging The Ilumipod 18 IP Optic Series consist of a cast aluminum mounting bracket with four 4 5mm screw holes ILUMINARC recommends following the general guidelines below when mounting the Ilumipod 18 IP Optic Series products e When selecting an installation location consider ease of access to the product for operation programming adjustments and routine maintenance e Never mount the product in places where restricted ventilation may affect it e Make sure that the location where you are mounting the product can support its weight Please see the Technical Specifications section of this manual for the weight requirement of this product Procedure The Ilumipod 18 IP Optic Series come with cast aluminum mounting brackets which you can attach to a flat mounting surface These brackets also serve as floor or wall mount supports You will have to use four mounting points per product llumipod 18 IP Optic Series User Manual Rev 08 LU MI NA RC Technical Information 4 Operation llumicode The products in the Ilumipod 18 IP Optic Series use an external controller the Ilumicode addresser to change their configuration llumicode Panel Description Button Function lt MENU gt Exits from the current menu or function Enables the currently displayed menu or sets the lt ENTER i 5 currently selected value into the s
29. uit or direct buried Wire US Wire Europe Black Brown Blue Green Yellow Green Yellow AC Power Input Wiring To provide signal for any of the Ilumipod 18 IP Optic Series You can connect the bare ended IP67 rated signal cable from the product to two IP67 rated signal connectors DMX in and DMX Out or use an IP67 rated junction box In this case make sure to use P67 rated You must run AC power and signal wires from the respective AC and signal distribution boxes into each of the Ilumipod 18 IP Optic Series products llumipod 18 IP Optic Series User Manual Rev 08 ILUMINARC Power Distribution Installation Connect the bare ended power cable from the product to a power distribution box as power cables away from the signal cables by running them in different conduits and using separate distribution boxes 0 Always keep the indicated below From ma fuse j ake sure to use power and signal panel cables with the ee indicated outer diameters to ensure that the corresponding gland nut makes full contact with nh Signal Distribution insulation This is required to keep the products IP67 rating when fully adjusted llumipod 18 IP Optic Series User Manual Rev 08 To other boxes Conduit Junction box Connect the bare ended signal cable from the product to a signal distribution box as indicated below Pini Common shield i AN Pin 2 Data In black Pin 3 Data In whit