Home
CB-7013, CB-7013D, & CB-7033, CB7033D User`s Manual
Contents
1. IEC 801 2 Electrostatic discharge requirements for industrial process measurement and control equipment IEC 801 3 Radiated electromagnetic field requirements for in dustrial process measurements and control equipment IEC 801 4 Electrically fast transients for industrial process mea surement and control equipment Carl Haapaoja Director of Quality Assurance CB 7013 CB 7033 User s Manual 43 Measurement Computing Corporation 10 Commerce Way Suite 1008 Norton Massachusetts 02766 508 946 5100 Fax 508 946 9500 E mail info mccdag com www mccdag com
2. 03M Receive 037033D Read address 03 module name returns name 7033D Related Command Sec 2 14 AAO Data 30 CB 7013 CB 7033 User s Manual 2 14 AAO Data Description Set Module Name Syntax AAO Data CHK cr Delimiter character AA Address of setting module 00 to FF O Command for set module name Data New name for module maximum six characters Response Valid Command AA CHK cr Invalid Command AA CHK Wier Syntax error or communication error may get no re sponse Delimiter for valid command Delimiter for invalid command AA Address of response module 00 to FF Example Command 0107013 Receive 01 Set address 01 module name to 7013 returns successful Command 01M Receive 017013 Read address 01 module name returns 7013 Related Command Sec 2 12 AAM CB 7013 CB 7033 User s Manual 341 2 15 AAEV Description Enable Disable Calibration Syntax AAEV CHK lier Delimiter character AA Address of setting module 00 to FF E Command for enable disable calibration V Enable 0 Disable calibration Response Valid Command AA CHK cr Invalid Command AA CHK cr Syntax error or communication error may get no response Delimiter for valid command 7 Delimiter for invalid command AA Address of response module 00 to FF Example Command 010 Receive 01 Perform addreess 01 span calibration return not enable calibration Command 01E1 Receive 01 Set address 01 to e
3. Leading Address Command CHK cr Response Format Leading Address Data CHK lier CHK _ 2 character checksum cr end of command character character return OxOD Calculate Checksum 1 Calculate ASCII sum of all characters of command or response string except the character return cr 2 Mask the sum of string with Offh Example Command string 012 cr Sum of string 0 1 2 24h 30h 31h 32h B7h The checksum is B7h and CHK B7 Command string with checksum 012B7 cr Response string 01200600 cr Sum of string 0 1 2 0 0 6 0 0 21h 30h 3 1h 32h 30h 30h 36h 30h 30h 1AAh The checksum is AAh and CHK AA Response string with checksum 01200600A A cr CB 7013 CB 7033 User s Manual 15 far fat cr EES E 2 gt Host Watchdog Command Sets uem Module Status M 2 17 Read Host I Sec 2 19 Timeout Value AA3ETT Set Host Watchdog Sec 2 20 Timeout Value CB 7013 CB 7033 User s Manual 2 1 AANNTTCCFF Description Set module configuration Syntax 4o AANNTTCCFF CHK ler Go A delimiter character AA Address of setting module 00 to FF NN New address for setting module 00 to FF TT New type for setting module Ref Sec 7 9 CC New baud rate for setting module Ref Sec 7 9 It is needed to short the INIT to ground while change baud rate Ref Sec 3 1 FF New data format for setting module Ref Sec 7
4. 1 9 Configuration Tables Note The command for CB 7033 33D only CB 7013 CB 7033 User s Manual POST 2 5 AA0 Description Perform Span Calibration Syntax SAA0 CHK cr Delimiter character AA Address of setting module 00 to FF 0 Command for span calibration Response Valid Command AA CHK cr Invalid Command AA CHK cr Syntax error or communication error may get no re sponse Delimiter for valid command Delimiter for invalid command AA Address of response module 00 to FF Example Command 010 Receive 01 Perform address 01 span calibration return successful Command 020 Receive 02 When performing address 02 zero calibration return was not enabled before performing calibration command Related Command Sec2 6 AA1 Sec 2 15 AAEV Related Topics Sec 1 6 Calibration 22 CB 7013 CB 7033 User s Manual 2 6 AA1 Description Perform Zero Calibration Syntax SAA1 CHK cr Delimiter character AA Address of setting module 00 to FF 1 Command for zero calibration Response Valid Command AA CHK cr Invalid Command AA CHK cr Syntax error or communication error may get no response Delimiter for valid command Delimiter for invalid command AA Address of response module 00 to FF Example Command 011 Receive 01 Preform address 01 zero calibration return successful Command 021 Receive 02 When performing address 02 zero calibration return was not enabled before
5. 3 3 Dual Watchdog Operation CB 7013 CB 7033 User s Manual a7 3 Application Note 3 1 INIT pin Operation Each CB 7000 module has a build in EEPROM to store configuration information such as address type baud rate and other information Sometimes a user may foget the configuration of the module Therefore the CB 7000 modules have a special mode named INIT mode to help user to resolve the problem The INIT mode is setting as Address 00 baud rate 9600 bps no checksum To enable INIT mode do the following steps Step 1 Power off the module Step 2 Connect the INIT pin to the GND pin Step 3 Turn power on Step 4 Send command 002 cr at 9600 bps to read the configuration stored in the module s EEPROM Refer to 7000 Bus Converter User Manual Sec 5 and Getting Started for more information 3 2 Module Status Power On Reset or Module Watchdog Reset will put all outputs to Power On Value And the module may accept the hosts command to change the output value Host Watchdog Time out will cause all digital outputs to go to their Safe Value The module s status read by command AAQO will be 04 and the output command will be ignored 38 CB 7013 CB 7033 User s Manual 3 3 Dual Watchdog Operation Dual Watchdog Module Watchdog Host Watchdog The Module Watchdog is a hardware reset circuit to monitor the module s operating status While working in harsh or noisy environment the m
6. 9 It is needed to short the INIT to ground to change checksum setting Ref Sec 3 1 Response Valid Command AA CHK cr Invalid Command 2AA CHK Wier Syntax error or communication error may get no re sponse Delimiter for valid command Delimiter for invalid command While change baudrate or checksum setting without short INIT to ground the module will return invalid command AA Address of response module 00 to FF Example Command 960102200600 Receive 02 Change address from 01 to 02 return successful CB 7013 CB 7033 User s Manual 17 Command 0202200603 Receive 02 Change data format from 00 to 03 return successful Related Command Sec 2 7 AA2 Related Topics Sec 1 9 Configuration Tables Sec 3 1 INIT pin Operation 18 CB 7013 CB 7033 User s Manual 2 2 sie Description Synchronized Sampling Syntax CHK lier A delimiter character x Synchronized sampling command Response No response Example Command He No response Send synchronized sampling command Command 014 Receive gt 0114 025 123 First read get status 1 Command 014 Receive gt 010 025 123 Second read get status 0 Related Command Sec 2 8 AA4 Note The command is for CB 7013 13D only CB 7013 CB 7033 User s Manual 19 2 3 HAA Description Read Analog Input Syntax AA CHK cr Delimiter character AA Address of reading module 00 to FF Response Valid Command _ gt Data CHK cr Syn
7. Configuration Note This command is for CB 7013D CB 7033D only Syntax A ASV CHK cr Delimiter character Address of setting module 00 to FF Command for set LED configuration For CB 7013D 1 Set LED to module 2 Set LED to host For CB 7033D 0 2 Set LED to show channel 0 2 3 Set LED to host Response Valid Command AA CHK cr Invalid Command 2AA CHK cr Syntax error or communication error may get no LE due response Delimiter for valid command U Delimiter for invalid command AA Address of response module 00 to FF Example Command 0180 Receive 01 Set address 01 LED to O return successful Command 0281 Receive 02 Set address 02 LED to 1 return successful Related Command Sec 2 9 AA8 Sec 2 11 AA9 Data CB 7013 CB 7033 User s Manual Sher 2 11 AA9 Data Description Set LED Data Note The command is for CB 7013D 33D only Syntax A A9 Data CHK cr Delimiter character AA Address of setting module 00 to FF 9 Command for set LED data Data Data for display on the LED from 19999 to 4 199909 The data needs a sign five digits and a decimal point Response Valid Command AA CHK cr Invalid Command AA CHK cr Syntax error or communication error may get no response Delimiter for valid command Delimiter for invalid command or LED not set to host control AA Address of response module 00 to FF Example Command 019 123 45 Receive 01 Send address
8. Drift 1 0uV C CMR 50 60 Hz 150dB min NMR 50 60 Hz 100dB min Displayed LED 41 digits CB 7033D only Power Supply Input 10 to 30VDC Consumption 1 0 W for CB 7033 1 6 W for CB 7033D CB 7013 CB 7033 User s Manual 7 1 4 Block Diagram 7013 7013D module EEPROM ET Photo Isolation al Senset Embedded A Controller 25 gt Sense Iexec B RS 485 A GND Interface P TSV Y Jere C BER 7033 7033D module Iexecr A Senset EEPROM zoma l Photo Isolation al li Sense Iexec Embedded Controller a Ei MUX S li Iexect Senset IH O l Sense Interface li Iexec bd A GND i Re gulatae 9 CB 7013 CB 7033 User s Manual 1 5 Wire Connection 2 wire RTD connection 3 wire RTD connection IEXEC SENSE SENSE IEXEC A GND IEXEC SENSE SENSE IEXEC A GND IEXEC 4 wire RTD connection SENSE SENSE IEXEC A GND CB 7013 CB 7033 User s Manual 9 1 6 Quick Start Refer to CB 7000 Bus Converter User Manual and Getting Start for more detail 1 7 Default Setting Default setting for CB 7013 13D CB 7033 33D e Address 01 e RTD Type Type 20 Pt100 100 C to 100 C e Baud rate 9600 bps e Checksum disable engineering unit format e Filter for 60 Hz rejection 1 8 Calibration Don t Do Calibration Until You Understand the Procedure Cal
9. performing calibration command Related Command Sec2 5 AAO Sec 2 15 AAEV Related Topics Sec 1 8 Calibration CB 7013 CB 7033 User s Manual 23 2 7 AA2 Description Read Configuration Syntax SAA2 CHK cr Delimiter character AA Address of reading module 00 to FF 2 Command for read configuration Response Valid Command AATTCCFF CHK cr Invalid Command AA CHK cr Syntax error or communication error may get no re sponse Delimiter for valid command 7 Delimiter for invalid command AA Address of response module 00 to FF TT Type code of module reference Sec 7 9 CC Baud rate code of module reference Sec 1 9 FF Data format of module reference Sec 1 9 Example Command 012 Receive 01200600 Read address 01 configuration return successful Command 022 Receive 102230602 Read address 02 configuration return successful Related Command Sec2 1 YAANNTTCCFF Related Topics Sec 1 9 Configuration Tables Sec3 INIT pin Operation 24 CB 7013 CB 7033 User s Manual 2 8 AA4 Description Read Synchronized Data Note This command is for CB 7013 13D only Syntax SAA4 CHK cr Delimiter character AA Address of reading module 00 to FF 4 Command for read synchronized data Response Valid Command gt AAS Data CHK cr Invalid Command AA CHK cr Syntax error or communication error may get no re sponse Delimiter for valid command Delimiter for invalid command AA A
10. time out status is set module is in safe mode Related Command Sec 2 16 Sec 2 18 AAl Sec 2 19 AA2 Sec 2 20 AA3EVV Related Topic Sec 3 2 Module Status Sec 3 3 Dual Watchdog Operation 34 CB 7013 CB 7033 User s Manual 2 18 AA1 Description Reset Module Status Syntax AAI CHK lier Delimiter character AA Address of setting module 00 to FF 1 Command for reset module status Response Valid Command AA CHK cr Invalid Command AA CHK cr Syntax error or comm error may get no response Delimiter for valid command 1 Delimiter for invalid command AA Address of response module 00 to FF Example Command 010 Receive 0104 Read address 01 module status return 04 host watchdog time out Command 011 Receive 01 Reset address 01 module status return successful Command 010 Receive 0100 Read address 01 module status return 00 no host watchdog time out Related Command Sec 2 16 Sec 2 17 AAO Sec 2 19 AA2 Sec 2 20 AA3EVV Related Topic Sec 3 2 Module Status Sec 3 3 Dual Watchdog Operation CB 7013 CB 7033 User s Manual 35 2 19 AA2 Description Read Host Watchdog Time out Value Syntax AA2 CHK cr Delimiter character AA Address of reading module 00 to FF 2 Command for read host watchdog time out value Response Valid Command AAVV CHK cr Invalid Command AA CHK cr Syntax error or communication error may get no response Delimiter f
11. 01 LED data 123 45 return successful Command 029 512 34 Receive 02 Send address 02 LED data 4512 34 Return indicates the LED is not in the host mode Related Command Sec 2 9 AA8 Sec 2 10 A A8V 28 CB 7013 CB 7033 User s Manual 2 12 AAF Description Read Firmware Version Syntax SAAF CHK cr Delimiter character AA Address of reading module 00 to FF F Command for read firmware version Response Valid Command 1A A Data CHK cr Invalid Command 2AA CHK cr Syntax error or communication error may get no response Delimiter for valid command Delimiter for invalid command AA Address of response module 00 to FF Data Firmware version of module Example Command 01F Receive 01A2 0 Read address 01 firmware version returns version A2 0 Command 02F Receive 01B1 1 Read address 02 firmware version returns version B1 1 CB 7013 CB 7033 User s Manual 29 2 13 SAAM Description Read Module Name Syntax A AM CHK cr Delimiter character AA Address of reading module 00 to FF M Command for read module name Response Valid Command 1A A Data CHK cr Invalid Command AA CHK cr Syntax error or communication error may get no re sponse Delimiter for valid command Delimiter for invalid command AA Address of response module 00 to FF Data Name of module Example Command 01M Receive 017013 Read address 01 module name returns name 7013 Command
12. CB 7013 CB 7013D amp CB 7033 CB7033D User s Manual BA at 4 AV Un MEASUREMENT COMPUTING Copyright Sept 2000 All rights are reserved Table of Contents I Ii rod uc Hon eege 4 1 1 More Information E 4 1 2 Pi EE 5 1 3 SPC C1 LIC ALM ONS E 7 1 BIOCK Bia Spain EE 8 1 We C ONE CU OM E 9 1 0 UICE SLA E 10 1 7 Default Settm E 10 1 Cat DE ae 10 1 9 Conneuration Tables unie hs 11 2 Command DEE 15 2I GAANNTICOCFE EE 17 HE 19 ENA HN DN NCF FERF FFRFFRFFFFRFFFFF FFR EEF US FU 20 2 d EA WEE 21 L SSAA EE 22 2 0 UA EEN 23 DM Po VP ERN TNT 24 PIT I VU Hee E CO OO O 25 ee 26 DOS 2929 ecc DCN 21 DAN S AA CD ata EEN 28 2 CB 7013 CB 7033 User s Manual AO SAND EE EE 2 qd E OUD E EE DAO VW EE PIENA Y eee eee ee ee ee UU UDIN 2 20 59 BV E 3 Application Notes scccccccsssssssssssssssccosees ST INDE pin Operaio o Mod le STIS RP Y aan a a 3 3 Dual Watchdog Operatnon HM CB COM 7013 amp 33 p65 CB 7013 CB 7033 User s Manual 1 Introduction CB 7000 is a family of network data acquisition and control modules They provide analog to digital digital to analog digital input output timer counter and other functions These modules can be remote controlled by a set of commands Common features of the CB 7013 13D and CB7033 33D are as follows e 24 bits sigma delta ADC for excellent accuracy e RTD direct connection e Software calibration The CB 7013 is a single channel RTD input module Th
13. Format a 0 00385 of FSR 100 00 100 00 100 to 100 e complemen degree pex 7FFF 8000 GE 0 0 00385 of FSR 100 00 00 1000 00 00 O to 100 s complemen degree ggx 1 7FFF 0000 EE ES Platinum 100 200 00 000 00 0 0 00385 of FSR 100 00 000 00 0 to 200 degree 7FFF 0000 Ge om 175 84 100 00 Platinum 100 600 00 000 00 m Se of FSR 100 00 000 00 to degree 7FFF 8000 Eus Om 313 59 060 60 Platinum 100 100 00 100 00 Ge GE of FSR 100 00 100 00 00 to degree JEFF 8000 Eu ES 139 16 060 60 Platinum 100 100 00 000 00 a 0 003916 of FSR 100 00 000 00 0 to 100 degree 7FFF 0000 Loo Jess In eere 100 00 CB 7013 CB 7033 User s Manual 13 Type Code RTD Type Platinum 100 36 a 0 003916 of FSR 100 00 000 00 0 to 200 2 s complement HEX 7FFF 0000 T Platinum 100 ang o 0 003916 of FSR 100 00 000 00 0 to 600 2 s complement HEX 7FFF 0000 Nickel 120 of FSR 100 00 080 00 28 80 to 100 degree Celsius 2 s complement HEX 7FFF 999A Nickel 120 o of FSR 100 00 000 00 29 0 to 100 degree Celsius 2 s complement HEX 7FFF 0000 Platinum 1000 T a 0 00385 of FSR 100 00 033 33 200 to 600 2 s complement HEX 7FFF degree Celsius 10 2 s Complement HEX Format Percent of FSR 9999 0000 2 s Complement HEX 7FFF 8000 S CB 7013 CB 7033 User s Manual 11 Ohms 2 Command Command Format
14. ddress of response module 00 to FF S Status of synchronized data 1 first read 0 been readed Data Synchronized data format reference Sec 1 9 Example Command 014 Receive 01 Read address 01 synchronized data return no data valid Command No response Perform synchronized sampling Command 014 Receive gt 011 025 56 Read address 01 synchronized data return status 1 and data Command 014 Receive gt 010 25 56 Read address 01 synchronized data return status O and data Related Command Sec2 2 CB 7013 CB 7033 User s Manual 25 2 9 AAS Description Read LED Configuration Note This command is for CB 7013D CB 7033D only Syntax A AS CHK J cr delimiter character AA address of reading module 00 to FF 8 command for set LED configuration Response Valid Command AAV CHK cr Invalid Command 2AA CHK lier Syntax error or communication error may get no re sponse Delimiter for valid command 7 Delimiter for invalid command AA Address of response module 00 to FF V LED configuration For CB 7013D 1 module control 2 host control For CB 7033D 0 2 LED show channel 0 2 3 LED is host control Example Command 018 Receive 011 Read address 01 LED configuration return 1 Command 028 Receive 012 Read address 02 LED configuration return 2 Related Command Sec 2 10 AASV Sec 2 11 AA9 Data 26 CB 7013 CB 7033 User s Manual 2 10 AA8V Description Set LED
15. e CB 7013D is the CB 7013 with a 4 digit LED display The CB 7033 is a three channel RTD input module The CB 7033D is the CB 7033 with a 4 digit LED display 1 1 More Information Refer to CB 7000 Bus Converter User Manual chap ter 1 for more information as following 1 1 CB 7000 Overview 1 2 CB 7000 Related Documentation 1 3 CB 7000 Command Features 1 4 CB 7000 System Network Configuration 1 5 CB 7000 Dimension 4 CB 7013 CB 7033 User s Manual 1 2 Pin Assignment CB 7013 CB 7033 User s Manual 0I NOD SA QD V LVd 5 FV LVd OD LINI IN5D V TAXIL TASNAS TASNAS T cOHXWI CB 7013 CB 7033 User s Manual 1 3 Specifications CB 7013 CB 7013D Analog Input Input Channel 1 Input Type 2 3 4 wire RTD RTD Type Pt100 a amp 0 00385 Pt100 a 0 003916 Ni 120 Pt1000 a 0 00385 version B1 0 or later Sampling Rate 10 Samples Second Bandwidth 5 24 Hz Accuracy 0 05 Zero Drift 0 5uV C Span Drift 1 0uV C CMR 50 60 Hz 150dB min NMR 50 60 Hz 100dB min Displayed LED 41 digits CB 7013D only Power Supply Input 10 to 30VDC Consumption 0 7 W for CB 7013 1 3 W for CB 7013D CB 7033 CB 7033D Analog Input Input Channel 3 Input Type 2 3 4 wire RTD RTD Type Pt100 a amp 0 00385 Pt100 a amp 0 003916 Ni 120 Pt1000 a 0 00385 Sampling Rate 15 12 5 Samples Second with filter at 60 50Hz Bandwidth 15 7 Hz Accuracy 0 1 Zero Drift 0 5uV C Span
16. ibration Requirement for CB 7013 13D version A1 x or A2 x Zero Calibration Resistor Span Calibration Resistor Calibration Requirement for CB 7013 13D version B1 0 or later and CB 7033 33D Zero Calibration Resistor Span Calibration Resistor 10 CB 7013 CB 7033 User s Manual Calibration Sequence 1 Connect calibration resistor to module by 4 wire R TD connection For CB 7033 33D connect to channel 0 2 Warm Up for 30 minutes 3 Set Type to 20 Ref Sec 2 1 4 Enable Calibration Ref Sec 2 15 5 Install Zero Calibration Resistor 6 Preform Zero Calibration Command Ref Sec 2 6 7 Install Span Calibration Resistor 8 Perform Span Calibration Command Ref Sec 2 5 9 Repeat step 4 to step 8 three times Note Step 4 is not needed for CB 7013 13D version A1 x or A2 x 2 Same for type 2A only diferent for set different type step 3 and install different Zero Span Calibration Resistor step 5 7 1 9 Configuration Tables owe o se Lew ow CB 7013 CB 7033 User s Manual 11 Configuration Table of CB 7013 13D CB 7033 33D Platinum 1000 o 0 00385 Baud rate Setting CC RTD Type Setting TT Note Type 2A is only for CB 7013 13D version B1 0 or later and CB 7033 33D Data Format Setting FF 1 Filter Setting 0 60 Hz rejection 50 Hz rejection 2 Checksum Bit 0 Disable 1 Enable 3 00 Engineering Unit Format 12 CB 7013 CB 7033 User s Manual 01 Percent
17. nable calibration returns successful Command 010 Receive 01 Preform address 01 span calibration returns successful Related Command Sec 2 5 AA0 Sec 2 6 AA1 Related Topic Sec 1 6 Calibration 32 CB 7013 CB 7033 User s Manual 2 16 Description Host OK Host send this command to all modules for send the information Host OK Syntax CHK cr delimiter character ee command for all modules Response No response Example Command No response Send Host OK to all modules Related Command Sec 2 17 AAO Sec 2 18 AAT Sec 2 19 AA2 Sec 2 20 AA3EVV Related Topic Sec 3 2 Module Status Sec 3 3 Dual Watchdog Operation CB 7013 CB 7033 User s Manual 33 2 17 AA0 Description Read Module Status Syntax AA0 CHK cr Delimiter character AA Address of reading module 00 to FF 0 Command for read module status Response Valid Command AASS CHK cr Invalid Command AA CHK cr Syntax error or comm error may get no response Delimiter for valid command 2 Delimiter for invalid command AA Address of response module 00 to FF SS host watchdog time out status 00 status is clear 04 status is set The status will store into EEPROM and only may reset by the command AAT Example Command 010 Receive 0100 Read address 01 module status return 00 Command 020 Receive 0204 Read address 02 module status A return of 04 means the host watchdog
18. odule may go down by the external noise signal The circuit may let the module to work continues and never halt The Host Watchdog is a software function to monitor the host s operating status Its purpose is to detect a network communi cation problem or host halt When a time out occurs the module changes all outputs to the safe state to prevent possible dangerous problems of a controlled unit process The CB 7000 module with Dual W atchdog makes the control system more reliable and stable CB 7013 CB 7033 User s Manual 39 40 For your notes CB 7013 CB 7033 User s Manual For your notes CB 7013 CB 7033 User s Manual 41 42 For your notes CB 7013 CB 7033 User s Manual EC Declaration of Conformity We Measurement Computing Corporation declare under sole responsibility that the product CB 7013 CB 7013D RTD Input Modules CB 7033 CB 7033D Part Number Description to which this declaration relates meets the essential requirements is in conformity with and CE marking has been applied accord ing to the relevant EC Directives listed below using the relevant section of the following EC standards and other normative docu ments EU EMC Directive 89 336 EEC Essential requirements relat ing to electromagnetic compatibility EU 55022 Class B Limits and methods of measurements of radio interference characteristics of information technology equipment EN 50082 1 EC generic immunity requirements
19. or valid command Delimiter for invalid command AA Address of response module 00 to FF VV Time out value in HEX format count for 0 1 second 0120 1 second and FF 25 5 second Example Command 012 Receive 01 FF Read address 01 host watchdog time out value On return of FF the host watchdog time out value is 25 5 second Related Command Sec 2 16 Sec 2 17 AAO Sec 2 18 AA1 Sec 2 20 AA3EVV Related Topic Sec 3 2 Module Status Sec 3 3 Dual Watchdog Operation 36 CB 7013 CB 7033 User s Manual 2 20 AA3EVV Description Set Host Watchdog Time out Value Syntax AA3EV V CHK cr Delimiter character AA Address of setting module 00 to FF 3 command for set host watchdog time out value E Enable 0 Disable host watchdog VV Time out value from 01 to FF each for 0 1 second Response Valid Command AA CHK cr Invalid Command AA CHK Wier Syntax error or communication error may get no response Delimiter for valid command Delimiter for invalid command AA Address of response module 00 to FF Example Command 013164 Receive 01 Set address 01 enables host watchdog and time out value is set to 64 10 0 seconds returns successful Command 012 Receive 0164 Read address 01 host watchdog time out value Return 64 the time out value is 10 0 seconds Related Command Sec 2 16 Sec 2 17 A AO Sec 2 16 AAT Sec 2 19 AA2 Related Topic Sec 3 2 Module Status Sec
20. tax error or communication error may get no response gt Delimiter for valid command Data Analog input value reference Sec 7 9 for its format While using AA command to CB 7033 33D the data is the combination for each channel respectively Example Command 01 Receive gt 026 35 Read address 01 get data successfully Command 02 Receive gt 4C53 Read address 02 get data in HEX format successfully Command 03 Receive gt 0000 Read address 03 get data underrange Command 04 Receive gt 025 12 054 12 150 12 Read address 04 is I7033 17033D get 3 channel data Related Command Sec2 1 Jo9AANNTTCCFF Sec 2 7 AA2 Related Topics Sec 1 9 Configuration Tables 20 CB 7013 CB 7033 User s Manual 2 4 FAAN Description Read Analog Input from channel N Syntax FAAN CHK J cr Delimiter character AA Address of reading module 00 to FF N Channel to read Response Valid Command gt Data CHK Wer Invalid Command AA CHK cr Syntax error or communication error may get no re sponse gt Delimiter for valid command Data Analog input value reference Sec 9 for its format Delimiter for invalid command AA Address of response module 00 to FF Example Command 032 Receive gt 025 13 Read address 03 channel 2 get data successfully Command 024 Receive 02 Read address 02 channel 4 return error channel number Related Command Sec2 1 4o AANNTTCCFF Sec 2 7 AA2 Related Topics Sec
Download Pdf Manuals
Related Search
Related Contents
takeMS Secure Digital 512Mb Eminent EM7385 Husqvarna 2101 Chainsaw User Manual BAO6001-P/BAO6003-P fan built-in oven BAO6005 Portas de correr motorizadas Manual do usuário PMACPanel User Manual Magelis XBT-N - Guillevin Industrial Automation Group Snapper 520E Snow Blower User Manual 1.3 FOUNDATION フィールドバス Copyright © All rights reserved.