Home
SPECTRA FLOOD 18T3 (IP 66)
Contents
1. SPECTRA FLOOD 18T3 IP 66 Order code LEDJ256 USER MANUAL Spectra Flood 18T3 Safety WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP CAUTION INPUT VOLTAGE OF 100 240V SAFETY INSTRUCTIONS Every person involved with the installation operation amp maintenance of this equipment should Be competent Follow the instructions of this manual CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual Please note that damages caused by user modifications to this equipment are not subject to warranty Spectra Flood 18T3 Safety IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment e Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular caution e Never remove warning or informative labels from the equipment Do not open the equipment and do not modify the equipment Do
2. Neutral Blue AC Ground Green Yellow Power linking e The Spectra Flood 18T3 supports power linking You can link up to 8 products at 120 VAC or 16 at 240 VAC eThis product supplied with a fixed power input cord This product is not suppled with a power link cable however power cables are available as an option see page 8 Spectra Flood 18T3 Trouble Shooting Ohe or more tires No power to the fixture are completely dead Internal fuse has blown The controller is not connected Fixtures reset correctly but all are responding erratically or not at all to the controller The 3 pin XLR out of the controller does not match the XLR out of the first fixture i e signal is reversed Poor data quality Bad data link connection Data link not terminated with 120 Ohm termination plug Fixtures reset correctly but some are responding erratically or not at all to the controller One of the fixtures is defective and disturbs the data transmission on the link The 3 pin XLR Out on the fixture do not match pins 2 and 3 reversed 10 Incorrect addressing of the fixtures Check that the power is switched on and cables are connected Contact your Prolight dealer Connect the controller Install a phase reversing cable between the controller and the first fixture in the link Check the data quality If much lower than 100 the problem may be a bad data link connection poor quality or brok
3. adjust the brightness of the individual red green and blue LEDs press the ENTER button to scroll through the colours and use the UP and DOWN buttons to adjust each colour from 000 to 255 Example If you set r G and B to 000 the Spectra Flood 18T3 will have no LEDs on blackout If you set r to 255 and G and B to 000 the Spectra Flood 18T3 will be 100 Red Built in programmes To activate the units built in programmes press the MODE button to show Pr01 on the LED screen Now use the UP and DOWN buttons to scroll through the built in programmes from Pr01 to Pr10 Now tap the MODE button to select the desired speed and adjust by using the UP and DOWN buttons Press the MODE button once more to select the desired flash value and adjust by using the UP and DOWN buttons Speed values SP00 SP99 00 slow 99 fast Flash values FL00 FL99 00 slow 99 fast In Pr01 you can set a specific static colour When in P 01 Press the Enter button and use the UP and DOWN buttons to scroll through the list of built in static colours 0 White RGB 1 Red 2 Orange 3 Light Yellow 4 Green 5 Cyan 6 Blue 7 Purple 8 Pink 9 Yellow 10 Cool white 11 Warm white To add strobe Press the ENTER button again and use the UP and DOWN buttons to set strobe from FLOO to FL99 To confirm your setting press the ENTER bu
4. 72 80 Pastel green 81 89 Light cyan When CH6 is set to 26 255 programme speed 99 107 Light Blue 0 255 slow to fast 108 116 Medium blue 162 170 Light pink 171 179 Pastel blue Spectra Flood 18T3 DMX Programme Charts 6 channel mode DMX chart continued 180 188 Pastel Green 189 197 Pastel yellow To use the static colours set CH6 to value 1 25 198 206 Pastel purple 207 215 Pastel Cyan 216 224 Turquoise When CH6 is set to 26 255 use this channel for the programme speed 0 255 slow to fast 225 233 Pastel pink 234 242 Neutral white 243 251 Warm white 252 255 Cool white 0 255 Green 0 100 Blue 0 100 Static colours use CH2 for colour selection Seven colour fade in and out Three colour fade in and out Seven colour change 104 129 Three colour change 130 155 Seven colour fade Use CH2 for programme speed 0 255 slow to fast 156 181 Three colour fade 182 207 Red fade in and out 208 233 Green fade in and out 234 255 Blue fade in and out No function 5 Strobe slow to fast Spectra Flood 18T3 DMX Set up DMX 512 e DMX Digital Multiplex is a universal protocol used as a form of communication between intelligent fixtures and controllers ADMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT DMX terminals located on all DMX fixtures most controllers only ha
5. c shocks LED failure etc Do not endanger your own safety and the safety of others Incorrect installation or use can cause serious damage to people and property Spectra Flood 18T3 Introduction Introduction Features e 18 x 3W tri colour LEDs Beam angle 40 degrees e 0 100 dimming and variable strobe e DMX channels 1 3 4 5 or 6 selectable Static colour colour fade colour change colour mix auto master slave and DMX modes 4 push button menu with LED display IP rated power in out sockets Lux chart IP rated 3 pin DMX in out sockets 40 Lux 6270 2150 1024 614 396 e Power consumption 65W us Power supply 100 240V 50 60Hz IP rating IP66 o E A A Dimensions 325 x 225 x 192mm AH Weight 4 5Kg 0 M Overview 5 9 DA i AAA RIINA HAA SARA FAR 1 AARON ONORATO EEEE ma Identification I U N NW Wu uo N A O O n A A O Y O Y A ee Y Y N CI AO SEDO IFT PILL A 1 Tightening knobs 2 Mounting bracket DMN CA AMAS 8 Function buttons 9 Safety bond point Setup Operating Instructions 3 2 The Spectra Flood 18T3 Exterior is a DMX 512 controllable unit made up of high efficiency RGB LEDs and will operate in stand alone master slave or DMX control modes 3 Spectra Flood 18T3 Operation Modes Operation modes Colour mix mode To access the units colour mix mode you must be in the built in programmes mode choose Pr01 and select option 7 White RGB To
6. en cables missing termination plug or a defective fixture is disturb ing the link Inspect the connection and cables Correct the connection Repair or replace the damaged cables Insert a termination plug into the output socket of the last fixture Check that DMX address setting is correct Bypass one fixture at a time until normal operation is regained Unplug both connectors and connect them together Have the fixture serviced by a qualified technician Install a phase reversing cable between the fixtures or swap pin 2 and 3 in the fixture that behaves erratically Spectra Flood 18T3 Trouble Shooting Contact a technician for servicing Fixture blacks out suddenly The fixture is resetting the effect i if the problem persists Allow the fixture to cool down Fixture is too hot Make sure that all air vents are not blocked No Light Disconnect the fixture and return it The LEDs are damaged to your dealer The power supply settings do not match Disconnect the fixture and check the local AC voltage and frequency settings and correct if necessary 11 Spectra Flood 18T3 Notes Notes TZ Spectra Flood 18T3 Notes Notes 13 Spectra Flood 18T3 NOS Notes Correct Disposal of This Product Waste Electrical amp Electronic Equipment Applicable in the European Union and other European countries with seperate collection systems This marking shown on the product or
7. its literature indicates that it should not be disposed with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please seperate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product should not be mixed with other commercial wastes for disposal Create the right effect www prolight co uk
8. le must be daisy chained and cannot be split 8 Spectra Flood 18T3 DMX Set up Notice Be sure to follow figures 2 amp 3 when making your own cables Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behaviour common DMX 512 out s ioo J e DMX 512 in 3 pin XLR 9 MH 3 pin XLR DMX S XLR MALE SOCKET XLR FEMALE SOCKET XLR Pin Configuration 2 cold 1 ground J i 1 ground 2 cold Pin 1 Ground f I i Pin 2 Negative 1 E i 3Hot 3H t i Pin 3 Postive FIGURE 3 FIGURE 2 Special Note Line termination e When longer runs of cable are used you may need to use a DMX terminator on the last unit to avoid erratic behaviour LEDJ260 Termination reduces signal transmission problems and interferance it is always advisable to connect a DMX terminal resistance 120 Ohm 1 4 W between pin 2 DMX and pin 3 DMX of the last fixture AC Plug e The Spectra Flood 18T3 features captive power cords terminated with IP66 connectors for power input and power linking The fixture is then supplied with a short 13A to IP66 connector power cord If at any stage the 13A plug is removed please follow the chart below Any changes to the connector types must be verified by a PAT test or equivalent electrical safety test Connection Wire Europe AC Live Brown AC
9. not connect this equipment to a dimmer pack Do not switch the equipment on and off in short intervals as this will reduce the system s life Do not expose to flammable sources or gases e Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable e Make sure that the available voltage is between 100V 240V e Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically Avoid direct eye exposure to the light source while the product is on If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again If your product fails to function correctly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Prolight dealer for service Only use fuses of same type and rating Repairs servicing and power connection must only be carried out by a qualified technician THIS UNIT CONTAINS NO USER SERVICEABLE PARTS WARRANTY One year from date of purchase OPERATING DETERMINATIONS If this equipment is operated in any other way than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns electri
10. tton Note F 00 slow F 99 fast Auto run mode To activate the units auto run mode press the MODE button to show AUTO on the LED screen The unit will now run through its built in programmes DMX Mode To activate the units DMX mode press the MODE button to show d001 on the LED screen and use the UP and DOWN buttons to set the first digit in the DMX address from 0 to 512 To choose one of the 5 DMX channels press the ENTER button and use the UP and DOWN buttons to scroll the through the 1 3 4 5 and 6 channel options To confirm your choice press the ENTER button For DMX functions please see the DMX charts below Master salve mode To set the unit as the master simply use any of the above modes on the unit To set the unit as a slave unit s press the MODE button to show SLAV on the LED display The unit will follow in sequence with the master unit 4 Spectra Flood 18T3 DMX Programme Charts 1 channel mode DMX chart ee 184 206 Dark Blue 253 255 Warm White 3 channel mode DMX chart 4 channel mode DMX chart 0 255 Master dimmer 0 100 Spectra Flood 18T3 DMX Programme Charts 5 channel mode DMX chart 1 Red 0 100 Green 0 100 0 255 Master dimmer 0 100 0 255 Strobe slow to fast 6 channel mode DMX chart 0 255 Red 0 100 only when CH6 is set to 0 To use the static colours 63 71 set CH6 to value 1 25 2
11. ve a data out terminal DMX Linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain DATA Cable DMX cable requirements for DMX operation e The Spectra Flood 18T3 can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data input output Further exterior DMX and power cables IP Rated Exterior Power Cable can be purchased from all good sound and lighting suppliers or Prolight dealers Please quote DMX Power LEDJ141 1M LEDJ146 1M LEDJ142 2M LEDJ147 2M IP Rated Exterior DMX Cable marge LEDO TAS OM LEDJ144 10M LEDJ149 10M Interior to exterior DMX LEDJ91 1M Interior to IP Rated Exterior DMX Cable Also remember that DMX cab
Download Pdf Manuals
Related Search
Related Contents
Reglas Generales de seguridad – Para todas las herramientas que M, monde - Collage Milano SISTEMA PERUANO DE INFORMACIÓN JURÍDICA Autonomie régionale et solidarité : une alliance durable ? 1 e-sphygTM 2 - American Diagnostic Corporation Jøtul F 602 Adnaco-S5 20Gb/s PCI Express Over Fiber Optic System User`s Guide guide de rédaction - Faculte des arts Copyright © All rights reserved.