Home

RANGE HOOD INSTALLATION INSTRUCTIONS - USE

image

Contents

1. 5 4 PREPARE THE HOOD Ged gee ae we eR 5 6 5 INSTALL THE ADAPTER DAMPER 6 7 INSTALL THE HOOD season HEGE hetsende kasse dw ois Se So kes 7 T CONNEGT WIRING 7 8 REINSTALL BOTTOM PANEL AND FILTERS 4 4 2 8 9 FLUORESCENT LAMPS sas krav ge retera ske boas Gr ow whe hee wee Skeet 8 CLEANING 525 eee RE 9 OPERATIONS et aod se ge Eh ab aa Retains talon fa aod Aran G 10 12 SERVICE PARTS 555 alee eh ee SET 11 12 1 INSTALL DUCTWORK Plan where and how the ductwork will be installed Install proper sized ductwork elbow s and roof or wall cap for the type of blower you are installing If using 6 150 mm round ducts use a transition Use 2 50 mm duct tape to seal duct joints Roof cap 6 round duct 3 x 10 duct 3 x 10 to 6 round transition Wall cap Hood HH0011A HH0014A 2 MEASURE THE INSTALLATION Dimensions for the most common installations are shown below We recommend to install the hood at a minimum of 20 508 mm from an electric range and at 24 610 mm from a
2. 5 HDO151A HD0150A 4 PREPARE THE HOOD Remove both filters from the hood Disassemble the adaptor damper A from the hood NOTE The adapter damper is located inside the hood Remove the bottom panel B to access the adapter damper Refer to figure beside HO0091 4 PREPARE THE CONT D Punch out the appropriate electrical knock out hole Using long nose pliers remove the knock out for the chosen opening vertical on top or horizontal at the back of the hood See figures below VERTICAL DISCHARGE HORIZONTAL DISCHARGE 5 INSTALL THE ADAPTER DAMPER NOTE If this hood replaces another one please note that the location of the air exhaust can vary from one manufacturer to another HORIZONTAL DISCHARGE NEW INSTALLATION HORIZONTAL DISCHARGE HOOD REPLACEMENT Fold down the foldable flange C of the It may be necessary to adjust the adapter damper location adapter damper This flange must be at 90 from the to the existing wall discharge opening Leave the foldable remaining flanges Use the lower screw holes on flange C of the adapter damper as is Use the upper each side of the adapter damper to assemble it to the screw holes on each side of the adapter damper to back of hood See beside assemble it to the back of hood See beside 5 INSTALL THE ADAPTER DAMPER CONT D VERTICAL DISCHARGE For vertical discharge i
3. and pull fluorescent lamps out of their socket NOTE Some fluorescent lamps may produce a yellowish lighting on first usages This temporary effect will disappear out in time by itself 10 CLEANING grease filters bottom panel intake ring and blower wheel should be cleaned frequently Use warm detergent solution The grease filters intake ring and blower wheel are dishwasher safe Clean all metal filters in the diswasher using non phophate detergent Discoloration of the filter may occur if using phosphate detergents or as result of local water conditions but this will not affect filter performance This discoloration is not covered by the warranty To remove the blower wheel first take off its intake ring Then remove the blower wheel by pulling it down smoothly NOTE Do not try to remove the black part attached to the bottom panel When reinstalling the blower wheel make sure the small tab D will fit into one hole of the motor STAINLESS STEEL CLEANING HD0221 PARR lt TRINN IN HD0156 Do e Regularly wash surfaces with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent e Always clean in the direction of original polish lines e Always rinse well with clear water 2 or 3 times after cleaning Wipe completely dry You may also use a specialized
4. gas range For optimal performance the hood should not be installed more than 30 762 mm from cooktop 30 maximum 20 minimum clearance clearance 24 for gas Standard Standard 36 height 36 height cooktop cooktop 3 PREPARE THE INSTALLATION Make sure the following items are included Hood Filters 2 Adapter damper assembly 3 x 10 located inside the hood under the bottom panel fluorescent lamps 120 V 13 W PLC13 2700 with G24q 1 base packed behind the light diffuser Bag of parts located inside the hood under the bottom panel including 1 wire clamp 5 no 8 x 1 2 double thread screws 2 wire connectors and 6 no 6 x 1 2 screws Part sold separately Transition 3 x 10 to 6 round optional for 6 round ducts installation only CAUTION When performing installation servicing or cleaning the unit it is recommended to wear safety glasses and gloves NOTE bottom of the cupboard is recessed attach wood strips not included as shown beside in order to properly install the range hood under the cabinet The wood strips must be as thick as recess 2 gt I N Cut out the openings for duct A and power cable B in cabinet or wall according to the direction of discharge chosen See figures below HORIZONTAL DISCHARGE VERTICAL DISCHARGE CABINET BOTTOM i lt 10
5. own Class ABC extinguisher and you know how to operate it B The fire is small and contained in the area where it started C The fire department has been called D You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFPA CAUTION 1 2 10 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors To avoid motor bearing damage and noisy and or unbalanced impeller keep drywall spray construction dust etc off power unit Your hood motor has thermal overload which will automatically shut off the motor if it becomes overheated The motor will restart when it will cool down If the motor continues to shut off and restart have the hood serviced The minimum hood distance above cooktop must not be less than 20 for an electric range and 24 for a gas range A maximum of 30 above cooktop is highly recommended for best capture of cooking impurities Two installers are recommended because of the large size and weight of this hood To reduce the risk of fire and to properly exhaust air be sure to duct air outside Do not exhaust air into spaces within walls or ceiling or into attics crawl space or garage Because of the high exhausting capacity of this hood you should make sure enough air is entering the house to replace exhausted air by opening a window close to or in the kitchen Use with approved cord c
6. Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors Do not use this unit with any solid state speed control device To reduce the risk of fire use only metal ductwork This unit must be grounded TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a b c 9 Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings Always turn hood ON when cooking at high heat or when cooking flambeing foods e g cr pes Suzette cherries jubilee peppercorn beef flamb Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter Use proper size Always use cookware appropriate for the size of the surface element A WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS IF THE FLAMES DO NOT GO OUT IMMEDIATELY EVACUATE AND CALL THE FIRE DEPARTMENT NEVER PICK UP FLAMING PAN You may be burned DO NOT USE WATER including wet dishcloths or towels This could cause violent steam explosion Use an extinguisher ONLY if You
7. H FILTER THE PAIR V06727 INSTALLATION amp USER MANUAL HARDWARE BAG 1 WIRE CLAMP 2 WIRE CONNECTORS 6 No 6 x 1 2 scREws 5 NO 8 1 2 DOUBLE THREAD SCREWS PE No No DESCRIPTION QTY 1 2 jajaja jo jo jp Jo fo jo fo ja Item not shown HL0093 11 12 SERVICE PARTS MODEL QDE 0095 13296 V15434 DESCRIPTION ADAPTER DAMPER ROCKER SWITCH WHITE PAIR OVERLAY WHITE 4 15433 03623 ROCKER SWITCH BLACK PAIR OVERLAY BLACK FLUORESCENT LAMP V01752 V01765 LIGHT DIFFUSER 01988 V16119 BLOWER WHEEL PAN WHITE V16117 V01757 PAN BLACK INLET RING V14131 V02104 MICROMESH FILTER THE PAIR SECONDARY CAPACITOR 7 5UF V06756 CAPACITOR 11 5uF V03649 BALLAST HARNESS SOCKET LAMPS INCLUDED V06727 INSTALLATION amp USER MANUAL V04281 Item not shown HARDWARE BAG 1 WIRE CLAMP 2 WIRE CONNECTORS 6 No 6 x 1 2 SCREWS 5 NO 8 x 1 2 DOUBLE THREAD SCREWS 12 ak dr de
8. RANGE HOOD INSTALLATION INSTRUCTIONS USE AND CARE MODELS ESB10 ESN10 ESV10 QDE AND ESC270 Z INTENDED FOR DOMESTIC COOKING ONLY READ AND SAVE THESE INSTRUCTIONS INSTALLER LEAVE THIS MANUAL WITH HOMEOWNER HOMEOWNER CLEANING AND OPERATION INFORMATION ON PAGES 9 AND 10 ENERGY STAR V06727 rev A A WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty Before servicing or cleaning unit switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards including fire rated construction codes and standards Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guidelines and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning
9. eed To stop the blower operation set the rocker switch to the central position 0 ON OFF LIGHTING CONTROL SWITCH This 3 position rocker switch controls the lighting Press either on left side 1 or right side 1 to obtain full lighting To shut off the lights set the rocker switch to the central position 0 MECHANICAL PUSH BUTTON CONTROL A OFF Blower SWITCH Press on this switch to stop the blower operation SPEED BLOWER SWITCHES Press on left switch 1 to turn on the blower on low speed on middle switch 2 to turn on the blower on medium speed and on right switch 3 to turn on the blower on high speed ON OFF LIGHTING SWITCH Press on this switch to turn on the fluorescent lights and press again to turn them off 10 12 SERVICE PARTS MODEL ESB10 ESN10 AND ESV10 1 02 PART DESCRIPTION QTY No No ADAPTER DAMPER I ADAPTER DAMPER 01752 LIGHT DIFFUSER 01757 INLET RING MICROMESH FILTER THE PAIR V06727 INSTALLATION amp USER MANUAL HARDWARE BAG 1 WIRE CLAMP 2 WIRE CONNECTORS 6 No 6 x 1 2 SCREWS 5 8 1 2 DOUBLE THREAD SCREWS Item not shown HL0092 13296 ADAPTER DAMPER 16153 SMOKED GLASS 13296 GLASS HOLDER BLACK PAIR 16151 GLASS HOLDER WHITE PAIR 16152 GLASS HOLDER GREY PAIR 03623 FLUORESCENT LAMP 01752 LIGHT DIFFUSER 01988 BLOWER WHEEL 01757 INLET RING 14131 MICROMES
10. household stainless steel cleaner Don t Do not use any steel or stainless steel wool or any other scrapers to remove stubborn dirt e Do not use any harsh or abrasive cleansers Do not allow dirt to accumulate Do not let plaster dust or any other construction residues reach the hood During construction or renovation cover the hood to make sure no dust adheres to stainless steel surface Avoid when choosing a detergent Any cleaners that contain bleach will attack stainless steel Any products containing chloride fluoride iodide bromide will deteriorate surfaces rapidly Any combustible products used for cleaning such as acetone alcohol ether benzol etc are highly explosive and should never be used close to a range ENAMEL FINISH Clean with warm water and mild detergent only If discoloration occurs use a good enamel polish such as automotive polish DO NOT use rough abrasive cleaner or porcelain cleaner 11 OPERATION Always turn on the hood before begining cooking in order to establish an air flow in the kitchen Let the blower run for few minutes to clear the air after turning off the range SwITCH CONTROL A ON OFF BLower AND SPEED CONTROL SWITCH This 3 position rocker switch controls the blower speed Pressing on left side 1 will result in low speed operation while pressing on right side 2 will turn on the blower to high sp
11. nstallation only leave the foldable flange of the adapter damper as is This flange must be located towards the front of the hood See beside LL INSTALLATIONS Using two 1 2 screws secure the adapter damper to the top or back of the hood Tape the adapter damper to the hood using duct tape to seal it NOTES 1 For the best ventilation performance if a round duct must be used the duct diameter must be 6 or more Use a 3 x 10 to 6 round transition 2 The wall duct must be well prepared to receive the adapter Before performing the installation make sure the adapter fits easily in the duct 6 INSTALL THE HOOD Run power cable to installation location Place the hood at its location Using a pen mark the position of the screws smaller part of the embossed keyholes Remove the hood and install four 1 2 double thread screws at sides locations A leaving a 1 8 gap Place the wire clamp insert the cable in the hood and tighten the wire clamp to secure the cable Place the hood under the cabinet and slide it in position Make sure the adapter damper assembly enters the ducting and the damper opens freely Secure the hood by tightening the screws completely Install the last 1 2 double thread screw B in the remaining embossed hole A HD0217 7 CONNECT WIRING WARNING Risk of electrical shock Electrical wiring must be done by qualified personnel acco
12. onnection kit only Please read specification label on product for further information and requirements All demonstrator range hoods model numbers ending by D are not for sale unless their original power cord is removed ABOUT THIS MANUAL Please take note this manual uses the following symbols to emphasize particular information WARNING Identifies an instruction which if not followed might cause serious personal injuries including possibility of death CAUTION Denotes an instruction which if not followed may severely damage the unit and or its components NOTE Indicates supplementary information needed to fully complete an instruction NOTE Because this publication covers many hood models the illustrations are typical ones Some details of your unit may be slightly different of the ones shown TOOLS NEEDED TO INSTALL THE RANGE HOOD Phillips screwdriver no 2 or Robertson no 1 and no 2 Pair of long nose pliers to open thehorizontal or vertical discharge knockout hole Hammer and flat blade screwdriver to open the electrical knockout hole Sheet metal sheers Pair of pliers Scissors to cut duct tape Pen Wire stripper TABLE OF CONTENTS 1 INSTALL DUCTWORK bes eder Ghee aks rakne einer ad 4 2 MEASURE THE INSTALLATION 525 sa AEE eek eee wee ead 4 PREPARE THE
13. rdance with all applicable codes and standards Before connecting wires switch power off at service panel and lock service disconnecting means to prevent power to be switched on accidentally Connect cable to range hood wiring using included wire connectors Connect BLACK to BLACK WHITE to WHITE and GREEN or BARE WIRE to GREEN ground screw 1 A WARNING Do not forget to connect the ground 8 REINSTALL BOTTOM PANEL AND FILTERS Reinstall the bottom panel using the retaining screw previously removed in step 4 plus 4 others from parts bag Refer to illustration beside Then reinstall filters 00092 9 FLUORESCENT LAMPS WARNING This hood has fluorescent lamps containing mercury Dispose of appropriately according to local laws and requirements This range hood must use compact fluorescent lamps 120 V 13 W PLC13 2700 K with G24q 1 base included NOTE The range hood is shipped with both fluorescent lamps packed behind the light diffuser 1 To access fluorescent lamps remove the light diffuser by pushing on its both tabs and pulling it down 2 To install the fluorescent lamps slide their 4 prongs into their corresponding holes in their socket until secured Reinstall the light diffuser 00099 WARNING In order to prevent the risk of personal injury the fluorescent lamps must be cooled down before removing them To remove fluorescent lamps remove the light diffuser