Home

Metro Series Mobile Computing Workstations MPE

image

Contents

1. 37 Hardware Install Aa Adi 37 Software Installation zanso enn aea de ida nda ia 39 _ _ o KK A Maintenance and IO O Ann nee ententes 51 Clon es nn ee tt in 51 Power Supply Air Filteri n a a aa aaa aa a aaa aaa a i a aae aaen 51 Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 z InterMetro Industries Corporation Fuse R pl cement ti ai A AAA SE A AAA A ren lia 57 Storage and Transport Conditions 57 Troubleshooting cocinar aan incaico 58 TE Technical SDECIICAIONS ita asii onda E E E a E 63 Contacting InterMetro Industries Corporation 64 InterMetro Industries Corporation Contact Information ooooocinccnonoconcooncnononononanonan nono nooo conn conocio cn noconocananos 64 InterMetro Customer Service sise 64 A ANN 64 8 Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation References Document Number Title L01 502 Metro 1700 Series Mobile Computing Workstation Operations Manual L01 503 Metro 1800 Series Mobile Computing Workstation Operations Manual Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 InterMetro Industries Corporation 7 Introduction Mobile Rechargeable Power Supply The Metro MPE 7800 Nickel Metal Hydride NiMH Pow
2. EMERSON Metro Series Mobile Computing Workstations MPE 7800 Series Nickel Metal Hydride Power Supply Operations Manual Supplement L01 504 RevA Copyright O 2013 InterMetro Industries Corporation www metro com THIS PAGE INTENTIONALLY LEFT BLANK Notice InterMetro Industries Corporation reserves the right to make improvements or changes in the products described in this manual at any time without notice While reasonable efforts have been made in the preparation of this document to assure its accuracy InterMetro Industries Corporation assumes no liability resulting from any errors or omissions in this document or from the use of the information contained herein Copyright Notice This manual is copyrighted All rights reserved This manual may be printed for personal use only This manual whole or in part may not be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form for distribution This manual whole or in part may not be modified without prior consent in writing from InterMetro Industries Corporation Copyright O 2013 by InterMetro Industries Corporation 651 North Washington Street Wilkes Barre PA 18705 U S A Metro is a registered trademark of InterMetro Industries Corporation Windows is a registered trademark of Microsoft Corporation in the United States and other countries Contact Information InterMetro Industries Cor
3. The BatteryPro Desktop Status Window normally appears above the status tray icon It provides descriptive information of the charge status of the workstation power supply batteries including estimated times to complete charging or until fully discharged The Status Window will appear when BatteryPro is started if the Always Display Battery Status box is checked in the Configuration tab of the BatteryPro dialog see Configuration under BatteryPro Configuration and Status below Displaying the Desktop Status Window The Desktop Status Window is enabled for display in two ways 1 Open the BatteryPro dialog select the Configuration tab and left click on to check the Always Display Battery Status box see Configuration under BatteryPro Configuration and Status below 2 If the Desktop Status Window is not displayed right click on BatteryPro status tray icon and select and left click on Show Hide Status Window to display it Notice Using this method to display the Desktop Status Window will not change the Always Display Battery Status setting in the Configuration Ifthe Desktop Status Window is not displayed right click on Power Options BatteryPro status tray icon and select and left click on Exit Show Hide Status Window to display it Moving the Desktop Status Window You may move the Desktop Status Window by clicking on it and holding down the left mou
4. Found New Hardware Wizard Welcoese to the Found Now Hardware o Wizard ee Windows will detect a new device on the USB port and ess automatically open the Found New Hardware Wizard utility ne Click on No not this time Click Next button or type n to continue Install TUSB3410 Boot Device 3 Click on Install from a list or specific location Advanced a a Click Next button or type n to continue Choose Location of Driver Click on Search for the best driver in these locations Click on Include this location in the search O If necessary click on the Browse button to find the Saa ner location shown below Demet Pee pen h Pe a Dec bus a dos red Ju Pad he de on chocos mil be the de match be ens tarde Click Next button or type n to continue pue mas cues CI hx Navigate to and select with a left click as shown Select the folder that contas drivers for your hardware x Program Files Texas Instruments T13410XP where x is the main drive usually C drive RTL Click OK button to return to the dialog above 3 E Program Files To view any subfolders click a plus sign above a Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 45 InterMetro Industries Corporation Hardware Installation Hardware Installation Warning Ay The software you are installi
5. Permissions for Powervar Set Permissions for Powervar mn Select name of standard limited or restricted user Group or user names E Administrators ER VAdrinistrators 2 Click the check box under Allow for both Full Control and LB CREATOR OWNER RE Read a Power Users ER1 Power Users PT cvet LA lt Repeat for each affected user Click OK button to accept Full Control v Read 7 Click Cancel or red X button to exit without changing Sue due permissions gt Permissions for flouser Allow Deny For special permissions or for advanced settings click Advanced USB Driver Installation Plug in the USB cable to complete the installation of the required USB drivers Windows will detect the new device on the USB port and automatically perform the Found New Hardware utility as shown below Perform the following steps as shown For additional details contact InterMetro Customer Service 44 Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation Notice Additional driver files and procedure steps will be required to complete the USB driver installation for the Wyse V90 series or similar computer The installation of the Serial Port will require additional steps shown in the procedure below Please see also details below in Settings for the Wyse V90 Series or Similar Thin Client Computer
6. e What programs and or optional devices are you using on the workstation e See if you can cause the problem to occur again This may help you understand the source of the problem and will help you describe the problem if you must call InterMetro Customer Service for technical assistance e What LEDs on the Fuel Gauge are illuminated or flashing See also the Fuel Gauge Warnings below e Do you hear any beeps How many Are they long or short e Check the power supply fuses Are they intact Run Time The following are meanings and suggested solutions for various Run Time Errors Errors For more information call InterMetro Customer Service Unhandled Exception System Error only one usage SNMP service is running primarily a thin client computer XP error See Disable SNMP Services under Settings for the Wyse V90 Series or Similar Thin Client Computer above May also be caused by the conflict of multiple SNMP devices attempting to use the same computer resources Notification NET Framework not installed Install NET Framework 2 0 or higher See Installing NET Framework above NET Framework will not install or run on Wyse V90 series or similar thin client computer Increase RAMdisk size See Increasing RAMdisk Size under Settings for the Wyse V90 Series or Similar Thin Client Computer above 58 Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro I
7. a flash drive Double click on the file Extract BatteryPro Files Click on Extract all Files under Folder Tasks Extraction Wizard Automatically Starts Click Next button or type n to continue Click Cancel or red X button to stop extraction Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 39 InterMetro Industries Corporation Select Destination for Files Click Browse button or type r to set a different location to save the files Click Next button or type n to continue Click Back button or type b to return to previous screen Click Cancel or red X button to stop extraction Extraction Activity This screen will appear showing extraction progress Click Cancel or red X button to stop extraction Extraction Complete Click on check box Show extracted files to set whether you want to launch the window showing the extracted files when you click the Finish button Click Finish button to close window Notice If there are problems in the install process the Back and Cancel buttons may become available In that case Click Back button or type b to return to previous screen Click Cancel or red X button to stop extraction Extracted BatteryPro Files Note the BatteryPro files and their location 40 Me
8. DC power is available from the Power Supply even when the AC cord is disconnected from an AC outlet To remove DC power put the ON Extended Storage Switch in the Extended Storage OFF position Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 InterMetro Industries Corporation 21 Starting BatteryPro Application When installed BatteryPro is typically configured to start automatically when the host computer starts up No additional user action is required Notice BatteryPro requires the workstation computer to be connected via USB to the MPE 7800 USB B port The connection is already made if the workstation is delivered with the MPE 7800 and BatteryPro installed If BatteryPro is not running as indicated by the status tray icon shown below it can be started by double clicking on the BatteryPro icon shortcut provided on the desktop by the software installation Red ball with lightening bolt indicates BatteryPro is running and power supply batteries are charging P lt Uy 3 14PM Battery shape indicates BatteryPro is running and power supply is running on batteries example shown is fully charged state If BatteryPro is not running double click on the desktop shortcut to start BatteryPro Sioa eae Notice BatteryPro shortcut is also available from the Windows Start All Programs menu Notice The first time BatteryPro is launched the Windows Firewall may ask you i
9. NiMH Power Supply When installed BatteryPro is typically configured to start automatically when the host computer starts up No additional user action is required Notice BatteryPro requires the workstation computer to be connected via USB to the MPE 7800 USB B port The connection is already made if the workstation is delivered with the MPE 7800 and BatteryPro installed If BatteryPro is not running as indicated by the status tray icon shown below it can be started by double clicking on the BatteryPro icon shortcut provided on the desktop by the software installation Red ball with lightening bolt indicates BatteryPro is running and power supply batteries are charging m Battery shape indicates BatteryPro is running and power supply is running on batteries example shown is fully charged state 07 00 3 14PM F If BatteryPro is not running double click on the desktop shortcut to 4 start BatteryPro BatteryPro Notice BatteryPro shortcut is also available from the Windows Start All Programs menu Notice The first time BatteryPro is launched the Windows Firewall may ask you if you want to continue to block BatteryPro If this happens click the Unblock button BatteryPro Settings BatteryPro settings are configured through the BatteryPro dialog The BatteryPro dialog is entered by right clicking on the BatteryPro status tray icon highlighting with the mouse pointer and selecting Power Options with a
10. Select BatteryPro from the Windows Start All Programs menu Exit l Show Hide Status Window Right click on BatteryPro status Tray icon and select Power Options to enter BatteryPro configuration dialog Configuration The Configuration tab is the default display when the BatteryPro dialog is first displayed The Configuration tab allows setting of the BatteryPro Power Scheme and to set whether the Desktop Status Window will always be displayed see Desktop Status Window above Notice Power Scheme settings are grayed out and not available when a user has been restricted See below PO BatteryPro Default Configuration Tab Display Configuration Power Metes Allaims Hbemate Status Select Configuration tab in BatteryPro dialog appears first when BatteryPro dialog is first opened Power scheme setting Tum off montor Set the following 1 Power Scheme Settings 2 Always Display Battery Status 7 Always Display Battery Status Click on Apply or OK button to apply new values OK also minimizes the dialog back to the status tray Click on Cancel button or X to minimize the dialog back to the status tray icon without applying changes Click on another tab to view or edit other settings 28 Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation Configuration Tab Display When User Acc
11. Tab Select Hibernate tab in BatteryPro dialog While holding down Ctrl key click on Monitor icon in upper left of dialog to reveal hidden Diagnostics tab Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 35 InterMetro Industries Corporation Diagnostics Tab Display Conta Poner Meler Alains Hbenae Status Diagnosics FA R teh l E EnatleTrace Enable Snapshot every 5 seconde Sew ae Tok When revealed select Diagnostics tab in E BatteryPro dialog In this display each battery pack may be individually monitored for detailed diagnostic purposes The Hide button hides the Diagnostics tab again Click on Apply or OK button to apply new values OK also minimizes the dialog back to the status tray Click on Cancel button or X to minimize the dialog back to the status tray icon without applying changes Click on another tab to view or edit other settings Hide Diagnostics Tab Click the Hide button to hide the Diagnostics tab again Refresh All Checkbox Click the Refresh All checkbox is an advanced function to enable continuous refresh of the Diagnostics tab data display The data will refresh every approximately 15 seconds Enable Trace and Enable Snapshot Checkboxes The Enable Trace and Enable Snapshot checkboxes are advanced functions for test purposes onl
12. actions to be taken by BatteryPro when the alarms occur Configuration Power Meter Alarms Hibernate Status Low Battery Alarm Activate low battery alarm when power level reaches 20 0 if 100 E Alarm Action E Notification Text Only Action None Critical Battery Alarm Y Activate low battery alarm when power level reaches 4 0 Y 100 Alarm Action Notification Sound Text Action None Configuration Power Meter Alarms Hibernate Status Activate low battery alarm when power level reaches Activate low battery alarm when power level reaches E Default Alarms Tab Display Select Alarms tab in BatteryPro dialog Set Low Battery and Critical Battery Alarm threshold levels by 1 Click check box to activate alarm 2 Click on and while holding down mouse button drag pointer on threshold slide bar Percentage is battery discharge level when the alarm will activate Notification and perform the Action shown 3 Click on Alarm Action button to set Alarm actions New dialog will pop up see below Click on Apply or OK button to apply new values OK also minimizes the dialog back to the status tray Click on Cancel button or X to minimize the dialog back to the status tray icon without applying changes Click on another tab to view or edit other settings Alarms Tab Display When User Access Is Restricted Alarms sett
13. based on the current equipment load Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 25 InterMetro Industries Corporation 43 Dischargng 25 remaining 1 47 hours 1 47 hours 25 remaining o PV 1 17PM ES Discharging Y Level Power supply is not plugged into AC power and is running on batteries batteries near 4 charge Battery charge level is displayed as a percentage and calculated remaining run time based on the current equipment load Discharging Low Level Power supply is not plugged into AC power and is running on batteries Battery charge has dropped below threshold set for Low Battery Alarm see Alarms below Notice A Low Battery Alert message may be displayed if Display Message box is checked for the Notification action See Alarm Notification and Action Settings in Alarms below Low Alarm Mute Button If the Sound Alarm and Continuous boxes have been checked for the Notification action see Alarm Notification and Action Settings in Alarms below the Low Alarm Mute button will appear above the Status Window when the Low Battery Alarm activates Click on the Low Alarm Mute button to stop the alarm sound Discharging Critical Level Power supply is not plugged into AC power and is running on nearly discharged batteries Battery charge has dropped below threshold set
14. bet te a he ic Une de check boner tions dd os par Ow de te dm de mu ate echa loc pdas The de e hd wal de rod F Sash aote cede o DAO Eres 3 o Donna Pe cater do et the dc o o bd radin does rel Qemartinn ot q pu chocos wd bee Dew maon bo ou Nara Popes Fac les vaca 1089 C Oud mae eb chum Pee Gove de rota tn Lo Coe Hardware Installation The software you are installing for this hardware USB Serial Port has not passed Windows Lago testing to verify its compatibility with Windows XP Tell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing Continue Anyway 1 STOP Installation ete nds eut Pose mat white the ous md wat abt the sommes p den Soete x The de meme op 2e diam Tn ft ia Pack DTD remind Ex Tapa Pe pah cd te De a od weed e ch Capp fins bom beeere 8 h 315 Laa TD Cc Jor A t 13 roe jae e ee a E Choose Location of Driver Click on Search for the best driver in these locations Click on Include this location in the search If necessary click on the Browse button and navigate to and select x Program Files Texas Instruments T13410XP
15. d men Nee De AM te age Pe Laon fes dattes w ne POA rh be Sine by Ade es 7 o thas onset arty be or by a aran ate ali ali ali Users Options Setup Restrictions Selection Click on Yes to allow all users to be able to configure all BatteryPro settings default setting Recommended Or click on No this should only be done by an Administrator to restrict certain changes to BatteryPro settings to Administrator privilege only See BatteryPro Configuration and Status sections on Configuration and Alarms above Click Next button or type n to continue Users Options Setup Shortcut Availability Selection Click on Everyone to allow shortcut to be setup for all users on their desktop and in the Windows Start All Programs menu default setting Recommended Click on Just Me to place shortcut only on the desktop and in the Windows Start All Programs menu of the Administrator user performing the installation Click Next button or type n to continue Choose Install Location Set Destination Folder for program installation Type in folder path in field and press Enter or click on Browse or type r and navigate to the desired location Click Next button or type n to continue Program installation will begin showing a window of activity until the Installation Complete screen below appears 42 Metro MPE 7800 Series
16. fan filter or outside vents are not clogged with lint or dust buildup See Power Supply Air Filter section above e Let cool for 2 hours e Turn on the power supply and restart the computer equipment e If this problem continues contact InterMetro Customer Service Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 59 InterMetro Industries Corporation Revision G PCBA Revision G e Power Supply uP O4 N 50 USB uP 04 N 33 METRO Part No 402624 The following Fuel Gauge warnings apply to the revision G of the MPE 7800 Series NiMH Power Supply only The revision label as shown is found on the main panel of the power supply Warning 1 NiMH Batteries Overheating e Air flow in the power supply may be restricted due to cooling fan not working properly fan blocked or clogged ventilation slots around the power supply case e Turn off computer equipment and then the power supply e Check that the fan is not blocked Check the ventilation slots around the power supply case for dust build up and clean e Turn on the power supply and restart the computer equipment e If this problem continues contact InterMetro Customer Service Warning 2 SLA Overvoltage e Not applicable to NiMH power supply e Turn off computer equipment and then the power supply e Turn on the power supply and restart the computer equipment e If this problem continues contact InterMetro Customer Servic
17. handle brackets screws and other hardware used in this procedure are usually taken from a previous power supply mounted on the workstation If replacement hardware is needed please contact InterMetro Customer Service 1 Attach two handle brackets one on each side of the power supply using three 8 32 pan head screws Be sure to put the right hand bracket on the right side and left hand on the left side the ramp tabs should be at the low end of the slant and to the outside 2 Facing the back of the workstation align the handle brackets inside the power supply mounts on the bottom of the workstation base Lift the power supply up and move toward the front of the workstation sliding the handle brackets up the ramp of the mounts until the tabs on lower ends of the brackets drop and catch in the slots on the mounts Secure each side with two 8 32 pan head screws Connect all cables DC Power connector RJ45 cable to the Gauge port USB to the USB B port If provided Notice USB connection is required for use with BatteryPro and AC cable Secure the AC cable with the clamp to the ground stud on the back of the power supply Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 37 InterMetro Industries Corporation Removing the MPE 7800 Power Supply A Caution For safety only qualified service personnel should perform the following procedure to remove the MPE 7800 Series Power Supply from the Me
18. it shall be a center tapped single phase supply circuit Electromagnetic Interference EMI Recommendations This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to other devices in the vicinity However there is no guarantee that interference will not occur in a particular installation If this equipment does not cause harmful interference to other devices which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving device Increase the separation between the equipment Connect the equipment to an outlet on a circuit different from that to which the other device s are connected Consult the manufacturer or field service technician for help Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 5 InterMetro Industries Corporation Revision History REY Revision Description Date Approved Issue A Initial Release 11 30 2009 V Bowman 1 Change in company contact information A 2 Update in cart label graphic endo Bowman 1 As per Metro Standards this Operations Manual is assigned with new Commodity Code L01 504 with Initial Release as L01 RevA with effective from 01 09 2013 504 2 Previous nomenclature of this doc
19. left click Right click on BatteryPro status Tray icon and select Power Options to enter BatteryPro configuration dialog i Exit Show Hide Status Window 16 Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation The tabs in the BatteryPro dialog shown below may be selected to view and configure the BatteryPro settings See the section BatteryPro Configuration and Status below Configuration Power Meter ll Alarms Hibernate Status i Power scheme settings Turn off monitor System Hibernates OK Cancel Flo BatteryPro Dialog Terminating BatteryPro BatteryPro can be stopped by right clicking on the BatteryPro400 status tray icon highlighting with the mouse pointer and selecting Exit with a left click l Right click on BatteryPro status tray icon and select and left click Power opion on Exit to stop BatteryPro Show Hide Status Window Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 17 InterMetro Industries Corporation AA AAN Operation The following section describes the basic function and operation of the MPE 7800 Series Nickel Metal Hydride NiMH Power Supply System Power Supply Location on the Metro Series Mobile Computing Workstation The MPE 7800 Series NiMH Power Supply is located in the bottom of the Metro Series Mobile Computin
20. LED marked LOW starts to flash plug the power supply into an AC outlet to avoid loss of system power which may cause loss of data Notice Once the NiMH Power Supply has been plugged into an AC outlet the Remote Fuel Gauge two green LEDs marked AC and CH turn on Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 19 InterMetro Industries Corporation Charge Status Seven 7 multi color LEDs green amber located on the Remote Fuel Gauge display the charging status of the NiMH power supply Fuel Gauge Status Battery is discharging under normal mobile operation Example shown is down to about 50 charge remaining Low battery LED flashing plug power supply into AC immediately AC indicates the power supply is plugged into the wall AC CH indicates the battery is charging The amber LEDs will turn on in sequence to indicate the charging status Example shown is up to about 50 charged AC indicates the power supply is plugged into the wall AC The Amber LEDs indicate the battery is fully charged Note that the CH LED is not lit because the battery is not being charged since the cycle is complete 20 Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation Charge Time Notice Extended Storage Notice Long Term Storage Longer than one week A Initial Charge Before
21. MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation Fuse Replacement A Caution For continued protection against risk of fire replace only with the same type and rating of fuse AC input 2x F 6 3 A 250 V Fast acting 6 3 A 250 V fuse 5 x 20 mm DC output F 10 A 250 V Fast acting 10 A 250 V fuse Y x 1 in Battery input F 20 A 250 V Fast acting 20 A 250 V fuse 4 x 1 in Storage and Transport Conditions Environmental conditions for shipping and storage are e Ambient temperature range of 40 C to 70 C 40 F to 160 F e Relative humidity range of 10 to 100 e Atmospheric pressure range of 14 76 in Hg to 31 29 in Hg Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 57 InterMetro Industries Corporation Troubleshooting General Tips If a problem occurs while you re working stop immediately If you continue you may lose data and destroy problem related information e Observe what is happening Write down what the power supply workstation computer and other devices are doing as well as what actions you took immediately before the problem occurred e What appears on the workstation monitor Record or capture a screen image of any messages that occur e Carefully read popup messages especially if you are also using BatteryPro they generally contain information that gives a solution to the problem that occurs
22. Meter Tab Display On Batteries Select Power Meter tab in BatteryPro dialog Shown at left is indication of running off battery Display includes battery specifications calculated run time and percent capacity of charge remaining Click on Apply or OK button to apply new values OK also minimizes the dialog back to the status tray Click on Cancel button or X to minimize the dialog back to the status tray icon without applying changes Click on another tab to view or edit other settings Power Meter Tab Display On AC Select Power Meter tab in BatteryPro dialog Shown at left is indication of plugged in and running off AC and charging Display includes battery specifications percent of capacity charged and time remaining until fully charged Click on Apply or OK button to apply new values OK also minimizes the dialog back to the status tray Click on Cancel button or X to minimize the dialog back to the status tray icon without applying changes Click on another tab to view or edit other settings 30 Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation Alarms Click on the Alarms tab to view or allow authorized users to change low and critical battery alert levels and actions settings Clicking on the Alarm Action buttons displays additional options for setting the messages and
23. NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation an ali Notification NET Framework version not 2 0 or higher If this notification appears during the installation activity O aoo 5 Click the No button and then the Cancel button in the See e Setup dialog to stop installation Perform the procedure a aeai Installing NET Framework below and then retry installing the BatteryPro application beginning at the start of this procedure above Notice Clicking the Yes button is not recommended the installation program will attempt to access the internet to download dotnetfx exe from the Microsoft website ali Installation Complete Completing the BatteryPre 2 0 0 36 Setup Wizard Click Finish button or type f to close window lt A Notice If there are problems in the install process the Back and Cancel buttons may become available In that case Click Back button or type b to return to previous LC screen Click Cancel or red X button to stop installation Installing NET Framework Run setup executable from the installation disk supplied or from the downloaded file from www metro com see Extracting the BatteryPro Package Files above The setup executable is named dotnetfx exe CT NET Framework Installation Run the Setup File From the folder of the extracted BatteryPro installation files s
24. ON Extended Storage Switch to the Extended Storage OFF position before attempting any maintenance or cleaning Turning off computers or disconnecting the AC power cord alone will not reduce the risk of electric shock because the Power Supply is internally powered by a battery Warning Risk of Electric Shock The AC power cord is the only means to disconnect the Power Supply and Metro Series Mobile Computing Workstation from the AC power grid mains The ON Extended Storage Switch on the Power Supply does not disconnect from main power On the other side the Power Supply employs a Nickel Metal Hydride NiMH battery to provide mobile DC output power Low voltage 10 16 VDC DC power is available from the Power Supply even when the AC cord is disconnected from an AC outlet To remove DC power put the ON Extended Storage Switch in the Extended Storage OFF position DANGER Risk of Explosion The Mobile Computing Workstation and the Power Supply are not for use in hazardous classified locations Do not use the Mobile Computing Workstation nor recharge the Power Supply battery in oxygen enriched areas areas where flammable anesthetics are used or stored or any other hazardous classified location Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation Caution USA 240 V A If an MPE 7800 series Power Supply is connected to a 240 V supply system in the United States of America USA
25. ab to view or edit other settings Always Display Battery Status checkbox The Always Display Battery Status checkbox controls the display of the Desktop Status Window e The Desktop Status Window is enabled to view immediately by left clicking on to check the box on the Scheme tab This performs the same function as the procedure in Displaying the Desktop Status Window above Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 29 InterMetro Industries Corporation e The Desktop Status Window is disabled and hidden from view immediately by left clicking on to un check or clear the box on the Scheme tab This performs the same function as the procedure in Hiding the Desktop Status Window above Power Meter Click on the Power Meter tab to view the current summary information about the power source and batteries FS BatteryPro Configuration Power Meter Alsims Hibeinate Status Power Status Battery Rabng Chemistry Hours Mins Remaining Capacity Remaining Power State OK 500 Wh NiMH 4 packs in slots 1256 12538 hours 99 On Batteries Cancel Configuration Power Meter Alarms Hibernate Status Power Status Current Power Source AC Battery Rating Chemistry Percent Charged Charge time remaining Power State Re 500 Wh NiMH 4 packs in slots 1 234 24 charged 2 50 hours to go On Utility Power
26. aining O 07 3 40am Ss 43 Discharging 48 remaining 3 14 hours 3 14 hours 48 remaining SB 07 11 39AM Communications Standby Power supply and workstation computer communications interrupted When BatteryPro starts the power supply and computer establish USB communications and BatteryPro performs a charge test for status of the power supply batteries The status should change to one of the states below if it does not the USB connection between the computer and power supply has a problem See Troubleshooting below Charging Power supply is plugged into AC power source and is charging the batteries Displays battery charge level as a percentage and calculated remaining charge time Charged Power supply is plugged into AC power source and the batteries are fully charged Discharging Full Level Power supply is not plugged into AC power and is running on batteries Battery charge level is displayed as a percentage and calculated remaining run time based on the current equipment load Discharging Power supply is not plugged into AC power and is running on batteries Battery charge level is displayed as a percentage and calculated remaining run time based on the current equipment load Discharging Half Level Power supply is not plugged into AC power and is running on batteries batteries near half charge Battery charge level is displayed as a percentage and calculated remaining run time
27. an the procedures detailed in the Maintenance section of this manual must be performed by qualified service personnel only For all service items please contact Inter Metro Customer Service Caution Do not operate an MPE 7800 series Power Supply or associated Metro Series Mobile Computing Workstation if either has received a severe impact been knocked over fallen down stairs or otherwise been physically damaged Please have a qualified service person inspect both the Mobile Computing Workstation and the Power Supply for any performance or safety hazard prior to putting it back into service Caution Ensure that the AC power supply cord is located and secured so that it will not be stepped on tripped over or otherwise subjected to damage or stress Please secure the AC power cord plug in the retaining clips provided on the Mobile Computing Workstation when it is unplugged from the AC outlet in order to prevent accidental tripping and physical damage to the cord plug or electrical insulation To prevent damage to any cords or connectors when disconnecting always grasp and pull by the connector and not the cord Do not operate the Power Supply or Mobile Computing Workstation with damaged cords or connectors Please replace the damaged component immediately Contact InterMetro Customer Service for replacement parts and service Caution To reduce the risk of electric shock unplug the Power Supply AC cord from an AC outlet and switch the
28. de vue pus def De mue ee Stat ponams Ce Cro aa Le _ as PET ILT ILE Guns re p A me Point mien e dy o gt ment m J ou _ use MOT e 1120 serve properties ec Compa us Cored Lng On Amma hora rane AO Cepia ramo DI Tp dr nan porn dy cd a gt VID get ar menthe De menage de Pah o omose CAICOS ramro e coe A hernan aa ad bes i j Vou cam peoh he Wat parameter thet aol shen you mat he rc on ewe Select SNMP Service Using side scroll find SNMP Service Right click on the SNMP Service and select and click on Permissions in the pop up menu Stop SNMP Service Click Stop button to stop SNMP service Click Cancel or red X button to exit without changing SNMP Service properties Disable SNMP Service Click on down arrow button next to Startup Type and from the drop down list select and click on Disabled Click OK button to accept Select SNMP Trap Service Using side scroll find SNMP Trap Service Right click on the SNMP Trap Service and select and click on Permissions in the pop up menu Disable SNMP Trap Service Click on down arrow button next to Startup Type and from the drop down list select and click on Disabled Click OK button to accept Close the Services and Administrative Tools windows ES pue cor M
29. e Warning 3 Both NiMH and SLA Batteries Detected e Should not occur in normal operation e Turn off computer equipment and then the power supply e Turn on the power supply and restart the computer equipment e If this problem continues contact InterMetro Customer Service Warning 4 Battery Fuse Blown e The power supply will shut down 2 minutes after the battery fuse has been detected as blown e Turn off computer equipment and then the power supply e Replace the Battery Input fuse see Fuse Replacement above e Turn on the power supply and restart the computer equipment e If this problem continues contact InterMetro Customer Service Warning 5 Failed Charge Test e Turn off computer equipment and then the power supply e Turn on the power supply and restart the computer equipment e If this problem continues contact InterMetro Customer Service 60 Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation Warning 7 SLA OVP Charge Test Quick Charge e Not applicable to NiMH power supply e Turn off computer equipment and then the power supply e Turn on the power supply and restart the computer equipment e If this problem continues contact InterMetro Customer Service Warning 9 Battery 0 detected e Power supply shuts off DC output e Turn off computer equipment and then the power supply e Turn on the power supply and restart the computer equipm
30. e Power e Disconnect the AC cable from the wall outlet Supply is off e Put the ON Extended Storage switch of the Power Supply to the Extended Storage OFF position Notice On some models of Metro Series Mobile Computing Workstation it may be necessary to access the Power Supply on the back by opening a cover Power Supply Cover Door door at the bottom of the cart Open Power Supply Cover Door As Required 52 Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation Flexible Filter Perform the following procedure to access and clean or replace the Cleaning flexible filter Replacement e Clear the cables away from the Power Supply fan area to reach the fan filter cover In some cases the DC power cable may need to be disconnected DC Power Fan Filter Assembly Connector Power Supply Back View e Open the fan filter assembly by pressing up the top filter cover with the index finger of your right hand Press up the filter cover Filter cover open Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 InterMetro Industries Corporation 53 e Remove filter from the assembly Fan Filter e Clean the filter by rinsing in running water or replace as required e Insert clean or new filter and press the top filter cover back down Insert filter Press down to close filter cover Replacement filters may be obtai
31. ee Extracting the BatteryPro Package Files above Double click on the dotnetfx exe After starting the install process above the NET Framework installation will begin Follow all instructions given The installation of NET will take substantial time Notice For NET Framework to run properly on the Wyse V90 series thin client computer it may be necessary to increase the RAMdisk size See Increasing RAMdisk Size under Completing for the Wyse V90 Series or Similar Thin Client Computer below Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 43 InterMetro Industries Corporation Permissions Setup for Standard or Restricted Windows User The default Windows settings for a user with standard privileges or the settings for an otherwise restricted user will not allow proper permissions for BatteryPro to run for those accounts The registry permissions must be changed for the BatteryPro registry location through the following procedure Run regedit Type the name of a program Folder document or ne LI Ve ua besa ERSTE From Windows Start menu select Run and enter oven EE x regedit ox cancel Crowe Click OK button to continue Open Permissions for Powervar Navigate to the folder My Computer HKEY_LOCAL_MACHINE SOFTWARE Powervar Right click on the folder and select and click on Permissions in the pop up menu
32. en Diagnostics tab is revealed through the Hibernate tab by holding down the Ctrl key and clicking on the Monitor icon see Diagnostics below r7 BatteryPro Hibernate Tab Display Confusion Poner Meter Amaro Statue Select Hibernate tab in BatteryPro dialog When pour computer hbemates it stores whatever has in memory on your hard disk and then shuts down When your Display in cl ud es computer comes out of hbemation it returns to its previous 1 Force hibernate click check box to C Enable Hbemation enable computer to enter hibernation mode 2 Available disk space and required disk space for hibernation Free disk space 16249 MB Disk space required to hibernate 512 MB Click on Apply or OK button to apply new values OK also minimizes the dialog back to the status tray Click on Cancel button or X to minimize the dialog back to the status tray icon without applying changes Click on another tab to view or edit other settings Notice While holding down Ctrl key click on Monitor icon in upper left of dialog to reveal hidden Diagnostics tab 34 Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation Status Click on the Status tab to view a quick glance summary of the power supply battery history and the BatteryPro version Configuration Power Meter Alarms Hib
33. ent e If this problem continues contact InterMetro Customer Service Warning 10 System Cannot Control Charging Current e Turn off computer equipment and then the power supply e Turn on the power supply and restart the computer equipment e If this problem continues contact InterMetro Customer Service Warning 11 Battery FET Failure e Turn off computer equipment and then the power supply e Turn on the power supply and restart the computer equipment e If this problem continues contact InterMetro Customer Service Warning 12 No Batteries Connected e Power supply shuts off DC output e Turn off computer equipment and then the power supply e Turn on the power supply and restart the computer equipment e If this problem continues contact InterMetro Customer Service Warning 13 SLA Quick Charge Timeout e Not applicable to NiMH power supply e Turn off computer equipment and then the power supply e Turn on the power supply and restart the computer equipment e If this problem continues contact InterMetro Customer Service Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 61 InterMetro Industries Corporation BatteryPro Diagnostics Popups Diagnostics History Log Warning 14 Heat sink Over Temperature e Power supply turns off charger e Air flow in the power supply may be restricted due to cooling fan not working properly fan blocked or clogged ventilation slo
34. er Supply is a rechargeable power source for the Metro Series Mobile Computing Workstations The Metro NiMH Power Supply is a fully automatic power supply charger system with a nominal DC output voltage of 14 4 Volts V and a battery capacity of 500 Watt hours Wh When it is plugged into an AC outlet it supplies the Mobile Computing Workstation system equipment while also charging the NiMH cells When unplugged from the outlet the power supply switches automatically to supply the workstation equipment from the internal NiMH rechargeable battery cells The power supply is designed for continuous operation and service is not interrupted by plugging in or unplugging the power supply MPE 7800 with Fan Filter MPE 7800 without Fan Filter 10 Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation Power Supply Status The status of the MPE 7800 series Power Supply is displayed by a remote Fuel Gauge display and optionally on the workstation monitor by the Metro BatteryPro software Remote Fuel Gauge Display The remote Fuel Gauge is embedded in the Metro Series Mobile Computing Workstation monitor mount at eye level height and is connected to the power supply It displays the battery charge level and state with a series of LED indicators Remote Fuel Gauge Display BatteryPro Mobile Computing Workstation Power Supply Management Software In a manner similar to no
35. ernate Status Information Full Charge Discharge Cycles Deep discharges 1 Average discharge level 50 Estimated full charge capacity 510 Wh Version 2 0 0 36 Diagnostics Status Tab Display Select Status tab in BatteryPro dialog Display includes power supply battery information 1 Charge cycle history 2 Estimated capacity Display also includes current BatteryPro software version Click on Apply or OK button to apply new values OK also minimizes the dialog back to the status tray Click on Cancel button or X to minimize the dialog back to the status tray icon without applying changes Click on another tab to view or edit other settings When revealed clicking on the Diagnostics tab provides a running list of power supply and battery data for troubleshooting purposes The Diagnostics tab is advanced functionality not meant for the general user Notice The hidden BatteryPro Diagnostics tab is revealed by holding down the Ctrl key and clicking on the Monitor icon in the Hibernate tab display see Hibernate above Configuration Power Meter Alaims Hibernate Status When your computer hbemates it stores whatever has in emory on your hard disk and then shuts down When your state C Enable Hibemation Free dsk space 16249 MB Disk space required to hibernate 512 MB OK Cancel _ App Reveal Diagnostics
36. es than expected 14 Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation Powering Up the MPE 7800 NiMH Power Supply The MPE 7800 Series NiMH Power Supply is controlled by the ON Extended Storage Switch located on the side of the unit ON Extended Storage Switch In the ON position the power supply provides power to the Metro Series Mobile Computing Workstation systems If the workstation is not used for an extended period of time the ON Extended Storage Switch should be put in the Extended Storage OFF position The switch position disconnects the battery from any internal or external equipment and avoids deep discharges of the battery which can cause damage to the battery ON Extended Storage Switch Warning Risk of Electric Shock The Power Supply employs a Nickel Metal Hydride NiMH battery to provide mobile DC output power Low voltage 11 16 VDC DC power is available from the Power Supply even when the AC cord is disconnected from an AC outlet To remove DC power put the ON Extended Storage Switch in the Extended Storage position Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 15 InterMetro Industries Corporation Starting BatteryPro BatteryPro Mobile Computing Workstation Power Supply Management Software is an optional application for monitoring the status of the MPE 7800 Series
37. ess Is Restricted Select Configuration tab in BatteryPro dialog Power Scheme settings are grayed out and not available to be changed Set the Always Display Battery Status only 2 Amay play Bator Staha Click on Apply or OK button to apply new values OK also minimizes the dialog back to the status tray Click on Cancel button or X to minimize the dialog back to the status tray icon without applying changes Click on another tab to view or edit other settings Power Scheme Setting The Power Scheme Setting sets two delays for when the workstation is not actively being used 1 Turn off monitor delay until the system turns off the workstation display monitor 2 System Hibernates delay until the computer enters hibernation Power Scheme Setting Click on down arrow at right of setting to open drop down list Configuration Power Meter Alarms Hibemate Status Power scheme settings Turn off monitor RES Click on desired time delay value use right side bar to System Hibernate ater 3 mn scroll down for more values After 5 min After 10 min Altor 15min Click on Apply or OK button to apply new values Always Display Battery Status OK also minimizes the dialog back to the status tray Click on Cancel button or X to minimize the dialog back to the status tray icon without applying changes Click on another t
38. etro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 49 InterMetro Industries Corporation Increasing RAMdisk Size Perform the following procedure to increase the RAMdisk size on the Wyse V90 series or similar thin client computer only to allow proper operation of NET Framework 4 Ramdisk Configuration RomDisk Cm _ y Fe A mom la x Roam Disk Limit fee current configuration in MB 100 Current Ramdak Size 100 MB L x _ MT a Cancel A AT Open Ramdisk from Control Panel From Windows Start menu select Settings gt Control Panel Double click on Ramdisk icon Set RamDisk size Enter new value or click on up arrow to increase size of RAMdisk It is recommended to maximize RAMdisk size Click on Apply or OK button to apply new values OK also closes the dialog Click on Cancel button or X to close the dialog without applying changes Close the Control Panel window Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation eS Maintenance and Storage Cleaning Use Metro Cleaner foaming aerosol available from InterMetro Customer Service or an equivalent mild hospital disinfectant to clean the exposed surfaces of the workstation on a regular basis Metro Cleaner is compatible with all of the components of the Metro Series M
39. f you want to continue to block BatteryPro If this happens click the Unblock button Windows Security Alert ES If Windows Firewall pops up the Security Alert shown Y To help protect your computer Windows Firewall has blocked the fi rst time BatteryPro is launched click the some features of this program Un block button i Do you want to keep blocking this program Name BatteryPro Publisher Unknown Keep Blocking Unblock Ask Me Later Windows Firewall has blocked this program from accepting connections from the Intenet or a network IF you recognize the program or trust the publisher you can unblock it When should unblock a program 22 Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation BatteryPro Status Indications BatteryPro has two ways of showing the status of the workstation power supply Both are shown in the lower right hand side of the computer display in and above the status tray 1 An icon in the status tray shows the state of the power supply batteries 2 The Desktop Status Window that can be hidden or moved anywhere on the workstation monitor display provides brief information of the state of the power supply batteries Status Icon The Status Icon in the status tray shows the charge status of the workstation power supply batteries Notice Placing the mouse pointer over the icon will reveal the charging stat
40. for Critical Battery Alarm see Alarms below Notice Itis recommended that the power supply be plugged into AC power immediately especially if the Shutdown Pending status is displayed Notice A Critical Alert message may be displayed if Display Message box is checked for the Notification action See Alarm Notification and Action Settings in Alarms below Critical Alarm Mute Button If the Sound Alarm and Continuous boxes have been checked for the Notification action see Alarm Notification and Action Settings in Alarms below the Critical Alarm Mute button will appear above the Status Window when the Critical Battery Alarm activates Click on the Critical Alarm Mute button to stop the alarm sound 26 Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation BatteryPro Configuration and Status BatteryPro settings are configured through the BatteryPro dialog window The BatteryPro dialog also displays more detailed status and diagnostic information The tabs in the BatteryPro dialog may be selected to configure and view the various BatteryPro settings and status e Configuration Displays and allows authorized users to change the BatteryPro Power Scheme settings and to reveal or hide the display of the Desktop Status Window e Power Meter Displays the current summary information about the p
41. g Workstation under the Base Deck The Remote Fuel Gauge located on the monitor stalk and the AC Power Cord associated with the Power Supply are also indicated La 1 Remote Fuel Gauge Base Deck H 0 dr i 0 Power Supply Metro 1700 Series Base Showing Location of Power Supply 18 Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation Powering Up the MPE 7800 NiMH Power Supply To turn on the Power Supply flip the ON Normal Operation Extended Storage switch located on the side of the power supply to the ON up position Metro MPE 7800 NiMH Power Supply ON Extended Storage Switch Remote Fuel Gauge To display the charge level of the NiMH cells when operating on DC power a Remote Fuel Gauge is connected to the power supply The embedded Remote Fuel Gauge is located just below the monitor in the stalk and gives the user the current battery status at eye level height Remote Fuel Gauge If the battery is fully charged all five 5 amber LEDs are illuminated The LEDs always display the battery charge level whether the computer is operating or not As the battery looses charge the LEDs gradually turn off one at a time Once the top four LEDs are off and only the amber LED marked LOW is illuminated and flashing it is recommended to plug the AC cord into an AC outlet as soon as possible to charge the battery Notice A Once the amber
42. hould only be connected to AC outlet receptacles which are marked Hospital Grade or Hospital Only Where the integrity of the external protective earth connector arrangement is in doubt equipment shall be operated from its internal electrical power source Disposal Steel sections of the power supply can be disposed of or recycled NiMH batteries shall be recycled through Rechargeable Battery Recycling Corporation www call2recycle org 1 877 2 RECYCLE Electronic components printed circuit boards etc shall be disposed of in accordance with local state and federal regulations For further information call InterMetro Customer Service Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 13 InterMetro Industries Corporation Getting Started Installation In general the Metro MPE 7800 Series NiMH Power Supply is provided already installed on a Metro Mobile Computing Workstation and is ready for use after fully charging the batteries The MPE 7800 Series NiMH Power Supply System can be retrofitted or installed new on a Metro Mobile Computing Workstation The power supply is self contained and is attached using the correct mounts on the bottom of the Metro Mobile Computing Workstation base BatteryPro is ready to install on the workstation computer Instructions for installing an MPE 7800 Series Power Supply and BatteryPro are provided in MPE 7800 Power Supply S
43. ings are grayed out and not available to be changed when a user has been restricted Click on Apply or OK button to apply new values OK also minimizes the dialog back to the status tray Click on Cancel button or X to minimize the dialog back to the status tray icon without applying changes Click on another tab to view or edit other settings Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 31 InterMetro Industries Corporation Alarm Notification and Action Settings Click on Alarm Action button to set Alarm actions There are separate settings for the Low Battery and Critical Battery Alarms eee Notification settings halo Click check boxes to set type of Notification BA desired Two types are available in any eg combination de ete 1 Sound Alarm a Windows Default Critical Error Program Error sound that runs one time only or continuously if the Continuous checkbox is selected The Continuous checkbox becomes available only when Sound Alarm is checked 2 Display Message a pop up warning message will appear on the screen See Critical Battery Alarm Actions Desktop Status Window above Notification Click on OK button to apply new value and exit v Sound Alarm Continuous the dialog v Display Message A Click on Cancel button or X to exit dialog When
44. ipment that is also internally powered According to the degree of protection against electric shock it is a Type B applied part According to the degree of protection against ingress of water the MPE 7800 Series NiMH Power Supply is considered ordinary Warning Risk of Explosion The MPE 7800 Series NiMH Power Supply is not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide The MPE 7800 Series NiMH Power Supply is suitable for continuous operation Important Product Notices The MPE 7800 Series NiMH Power Supply is a subsystem component of the Metro 1700 and 1800 Series Mobile Computing Workstations Please refer to the respective User Guide for the Mobile Computing Workstation to which the Power Supply is attached for additional information The Metro MPE 7800 Series NiMH Power Supply is only CSA certified if the equipment is left in its original configuration as shipped from InterMetro Industries Corporation If the user alters the power supply by changing components on or adding components to the power supply this will void the CSA certification of the power supply and the Mobile Computing Workstation and is expressly prohibited by InterMetro Industries Corporation The Power Supply used is provided with a Hospital Grade or Hospital Only attachment plug for connection to the AC supply circuit To ensure equipment grounding reliability the Power Supply s
45. ndustries Corporation Fuel Gauge Warnings O O The Power Supply Fuel Gauge flashes LEDs to indicate a detected problem Fuel Gauge warning LED indication legend Yellow or Green flashing LED Grey LED off White On or Off the state does not matter ignore the LED LOW LED flashing Battery nearing end of charge e Plug power supply into AC immediately The following Fuel Gauge warnings apply to the revision Fn where n is revision extension for example F3 of the MPE 7800 Series NiMH Power Supply only The revision label as shown is found on the main panel of the power supply AC LED flashing Fault detected e Refer to and record the message and action shown in BatteryPro fault popup window e Notice Ifthe battery fuse has blown the power supply will shut down within 2 minutes after the fault has been detected e Turn off computer equipment and then the power supply e Replace the Battery Input fuse if that is the fault reported see Fuse Replacement above typically most of the failures are this fault e Check that the fan filter or outside vents are not clogged with lint or dust buildup See Power Supply Air Filter section above e Turn on the power supply and restart the computer equipment e If this problem continues contact InterMetro Customer Service All LEDs flashing NiMH Batteries Overheating e Turn off computer equipment and then the power supply e Check that the
46. ned by calling InterMetro Customer Service Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation Easy Clean Perform the following procedure to access and clean the Easy Clean Metal Screen metal screen filter Filter Cleaning e Clear the cables away from the Power Supply fan area to reach the fan filter cover In some cases the DC power cable may need to be disconnected DC Power Fan Filter Assembly Connector Power Supply Back View e To remove the fan filter assembly grip the assembly handle between the thumb and index finger of your right hand and lift up to release the magnetic latching Grip filter assembly handle Lift handle up e Pull out the filter assembly Fan Filter E Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 55 InterMetro Industries Corporation e Clean the metal screen filter by rinsing in running water e Slip the filter assembly back in ensuring that the assembly slips under the two guides After the assembly is inserted fully pull down to ensure that it is flat on the power supply Insert filter under guides Pull handle down when fully in e Ensure the assembly is under the guides fully inserted and flat down as shown below Notice Ensure DC cable is properly reconnected and cables restored to position as shown DC Power Connector Power Supply Back View 56 Metro
47. ng for this hardware If yo u receive th is wa rn i ng i TUSB3410 Device he pot ped ea Loo se corp Click Continue Anyway button or type c to continue witl indows ell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing Continue Anyway STOP Installation Installation Process Activity 4 You will briefly see a dialog as the driver is installed D LE C ET p Completing Installation of TUSB3410 Device eo After the brief activity screen the completion screen will pep en appear Click on Finish button or press Enter key fs ee Found New Hardware Wizard ea Windows will detect another new device on the USB Pe eee ME port and automatically open the Found New Hardware a Wizard utility rss Click on No not this time Click Next button or type n to continue Ce Install Texas Instruments UMP Serial Port SES Click on Install from a list or specific location aa Advanced a cote nn Click Next button or type n to continue 46 Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation Fee a a or games Ehh ta de
48. obile Computing Workstation e Dampen a soft cloth with Metro Cleaner or equivalent cleaner e Wipe surfaces until clean e Do not spray Metro Cleaner into any openings like air vents or fan on power supply etc of the Power Supply e Do not use Metro Cleaner for medical devices used for patient contact EKG contacts etc Power Supply Air Filter Notice The MPE 7800 Series Power Supply Revision F4 and later has no external fan filter and is indicated by the label shown The vents around the outside of the power supply should be checked for lint or dust buildup periodically and cleaned periodically by brushing off the vents with a soft cloth or brush The following procedure for the Power Supply Air Filter applies only to and is required for the MPE 7800 Series Power Supply that has an external fan filter Revision F3 or earlier which may also be indicated by the label shown Please clean fitter to prevent shutdown due to overheating Notice In order to ensure proper cooling airflow the Power Supply air filter for the MPE 7800 Series NiMH Power Supply must be checked and cleaned or replaced every 2 months You will have one of two types of filters a flexible filter or an Easy Clean metal screen filter Perform the following procedure to access and clean or replace the filter Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 51 InterMetro Industries Corporation Ensur
49. ower source and batteries e Alarms Displays and allows authorized users to change the low and critical battery alert levels and actions settings e Hibernate Displays workstation computer disk requirements for hibernation allows forcing the computer into hibernation before a low battery shutdown condition occurs and contains the feature to reveal the hidden Diagnostics tab e Status Displays power supply battery history summary and BatteryPro version e Diagnosis Hidden tab when revealed displays power supply firmware version and power supply and individual battery data for troubleshooting purposes The following sections detail the functions of the tabs in the BatteryPro dialog Configuration Power Meter Alarms Hibemate Status Power scheme settings Turn off monitor System Hibemates Cancel Default Metro BatteryPro Dialog Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 27 InterMetro Industries Corporation Opening the BatteryPro Dialog Window The BatteryPro dialog is entered by right clicking on the BatteryPro status tray icon highlighting with the mouse pointer and selecting Power Options with a left click The dialog may also be entered if BatteryPro is already running through one of the following methods 1 Double click on the status tray icon 2 Double click on the BatteryPro shortcut on the desktop 3
50. poration North Washington Street Wilkes Barre PA 18705 Phone 1 800 992 1776 http www metro com support FCC Information This device complies with FCC Rules part 15 Operation is subject to the following conditions 1 This device may not cause harmful interference and 2 This device must accept any interference that may be received including interference that may cause undesired operation Notice This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s expense Warning Changes or modifications to this device not expressly approved by InterMetro Industries Corporation could void the user s authority to operate this equipment Shielded cables must be used with this unit to ensure compliance with the FCC Class A limits Industry Canada This class A digital apparatus meets all requirements of the Canadian Interface Causing Equipment Reg
51. pplement InterMetro Industries Corporation ee Technical Specifications Input Voltage Output Voltage Maximum Output Power Battery Type Short Circuit Protection Battery Capacity Charging Time Operating Temperature Charge Status Indicator Outlet rating Weight Approvals 100 240 VAC 50 60 Hz 5 A max 11 16 V 14 4 VDC nominal 120 W Nickel Metal Hydride NiMH 10 A fuse at the output 6 3 A fuse at the input 500 Wh 3 5 hours 10 C to 30 C 50 F to 86 F LED on remote fuel gauge Charge 6 carts per 20 A circuit 32 Ibs FCC Part 15 Subpart B Class A Industry Canada Class A UL60601 1 and CSA C22 2 No 601 1 IEC EN 60601 1 1 Safety Medical Equipment IEC EN 60601 1 2 EMC Medical Equipment RoHS compliant RoHS Directive 2002 95 EC Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 63 InterMetro Industries Corporation Contacting InterMetro Industries Corporation InterMetro Industries Corporation Contact Information InterMetro Industries Corporation 651 North Washington Street Wilkes Barre PA 18705 Phone 1 800 992 1776 http www metro com support InterMetro Customer Service For all customer service related issues or if you need technical assistance please call our customer service department at 1 800 992 1776 Americas 905 676 9890 Canada 31 76 58 77550 Europe 9714 811 8286 Middle East 65 6550 1291 Asia Pacific Repai
52. r Power Supply To return equipment for repair pm TT UE e Have model and serial numbers ready obtain either Tae the Power Supply information from its label or the e CORRE Workstation information from its label as shown at left Workstation e Contact InterMetro Customer Service at the contact na number given above to obtain a RMA number PLO 1700 MOBILE e Please write the RMA number on the air bill in the COMPUTING WORK STATION w A ETA DITA reference section on the outside of the package ATA e Return the equipment to ea me InterMetro Industries Corporation BOUT vane Y oosa A 3263 Elam Farms Pkwy Murfreesboro TN 37127 ASSEMBLED USA ree mene capi 64 Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation
53. s Display Battery Status Flo BatteryPro Dialog BatteryPro also provides the drivers needed for access across the network for Metro Dashboard Features The Metro MPE 7800 NiMH Power Supply features Rugged steel construction built to last Remote Fuel Gauge at the user s eye level NiMH 500 Wh capacity rechargeable batteries Fits conveniently in the base of the Metro Series Mobile Computing Workstations Software application Flo BatteryPro provides the power supply status on the Metro Series Mobile Computing Workstations monitor display o Status icon on Windows taskbar o Desktop status window o BatteryPro dialog to configure settings and view diagnostic data o Accessible across network by Metro Dashboard application Compatible with Metro 1700 and 1800 series Mobile Computing Workstations Standard USB connection between MPE 7800 Series Power Supply and workstation computer User manual supplement included 12 Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation Equipment Classification The Metro MPE 7800 Series NiMH Power Supply is CSA certified with respect to electric shock fire and mechanical hazards only in accordance with UL 60601 1 CAN CSA 22 2 No 601 1 and IEC EN 60601 1 1 as Type B Patient Care Medical Equipment suitable for use in patient vicinities The MPE 7800 Series NiMH Power Supply is a Class Equ
54. se button and then dragging it to any part of the monitor display Hiding the Desktop Status Window The Desktop Status Window is hidden disabled from display in two ways 1 Open the BatteryPro dialog select the Configuration tab and left click on to uncheck the Always Display Battery Status box see Configuration under BatteryPro Configuration and Status below 2 If the Desktop Status Window is displayed right click on BatteryPro status tray icon and select and left click on Show Hide Status Window to hide it Notice Using this method to hide the Desktop Status Window will not change the Always Display Battery Status setting in the Configuration Ifthe Desktop Status Window is displayed right click on Power Options BatteryPro status tray icon and select and left click on Exit Show Hide Status Window to hide it 24 Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation Desktop Status Window Indications Following are the indications and meanings of the Desktop Status Window Communications Standby Communications Standby DL 1 27PM 43 TE 77 charged 51 minutes to go 51 minutes to go 77 charged oO 0 2 9 42AM 43 Charged 100 Charged 43 Dischargng 100 remaining 6 15 hours 43 Dischargng 77 remaining 4 58 hours 14 58 hours 77 rem
55. tebook computer battery monitors BatteryPro Mobile Computing Workstation Power Supply Management Software displays the MPE 7800 series Power Supply status battery level as a percentage and calculated remaining run time The status is displayed on the Workstation display monitor using the Windows task bar and control panels BatteryPro also alerts the user when the power supply batteries are reaching the end of the discharge cycle so that the user can perform any one of three actions 1 Save any work and shut down the system 2 Allow the computer to shut down in an orderly manner with all data quickly stored onto the hard drive for Hibernation 3 Plug the power supply into a wall outlet to start charging the unit BatteryPro requires a USB connection from the USB port on the Power Supply to the Metro Series Mobile Computing Workstation computer The BatteryPro application features a status icon on the Windows taskbar and a status window A BatteryPro dialog see below can be opened to configure the power scheme and notifications and view more detail status of the power supply system A diagnostic tool can also be accessed through the BatteryPro dialog Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 11 InterMetro Industries Corporation Configuration Power Meter Alarms Hibemate Status Power scheme settings Turn off monitor Never System Hibemates Never 7 Alway
56. teps as shown for the Wyse V90 series or similar thin client computer only For additional details contact InterMetro Customer Service Disable SNMP Services Perform the following procedure to disable the SNMP Services on the Wyse V90 series or similar thin client computer only Failure to complete this procedure may result in an SNMP error when you attempt to run BatteryPro AAA Select Administrative Tools from Control Panel Cm e om 2 2 From Windows Start menu select Settings gt Control m Panel Double click on Administrative Tools icon AA pa Open Services in Administrative Tools mr E In Administrative Tools double click on Services te y icon 5 BE a 48 Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation i i vecccecece tit f loe SE re e Pespertere Local Coma 213 Gord Log On econe tera Taps Sense iee Me wowe MEE Oungan innies ageh that marten Pa m e reo Cre ord moet Pe et car aowe oaair Seed 0 ne Coe Vou Cam Gacy he fat a Met coe afer pou at he AA as os Coca a rr e Presos Local Compa ys Genera Login Meco Agere fare Seos ime 2P Dya DF Dustin breton agents al marin bn ey mn rato Cece art pet to te rat corde Path o mue CMD OS Lane Long dun mo ns lean tee Domei id a le dut pa Dot au
57. the alarm goes off the computer will without saving change to settings 32 Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation Low Battery Alarm Actions Notification v Sound Alarm Display Message Alarm Action v When the alarm goes off the computer will Hibernate v Shutdown Critical Battery Alarm Actions Notification v Sound Alarm Continuous v Display Message Alarm Action v When the alarm goes off the computer will Shutdown v Hibemate Alarm Action setting Click check box to enable an Alarm action to be performed when the alarm occurs Click on down arrow at right of setting to open drop down list Click on desired action Hibernate or Shutdown If enabled by the checkbox the workstation computer will perform the selected action when the alarm level is reached Click on OK button to apply new value and exit the dialog Click on Cancel button or X to exit dialog without saving change to settings Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 InterMetro Industries Corporation 33 Hibernate Click on the Hibernate tab to display disk space requirements and availability for workstation computer hibernation and to enable immediate computer hibernation The hidd
58. tice Typically the BatteryPro Mobile Computing Workstation Power Supply Management software and drivers are installed at the factory and no additional installation is required Notice The software package should already be installed on the workstation computer before plugging in the USB cable Notice All procedure steps contained in this section for installation and setup of the software application and drivers must be performed by a user logged in as Administrator Notice Microsoft NET Framework 2 0 or higher must be installed on the workstation computer before installing BatteryPro software and its drivers See Installing NET Framework below For any problems with application installation or settings please first consult your IT department before contacting InterMetro Customer Service Extracting the BatteryPro Package Files The BatteryPro software NET Framework 2 0 and the electronic version of this manual are packaged in the file BatteryPro 2 0 0 xx zip where xx is the latest released version which is supplied on an installation disk or can be downloaded from the www metro com Contact InterMetro Customer Service for additional details D mm nner MA Save BatteryPro Software Package owt Dos ie Du Pues rem T Copy the downloaded file or file from supplied disk mn 221 BatteryPro 2 0 0 xx zip to a directory location on local hard disk Administrator documents location recommended or to
59. tro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation Application Installation Run setup executable from the installation disk supplied or from the downloaded file from www metro com see Extracting the BatteryPro Package Files above The setup executable is named Setup_BatteryPro 2 0 0 xx exe where xx is the latest released version and will install the BatteryPro application D fatteryPro 2 0 0 36 The pubieher could not be vente Ave pou nse pou want to fun thes software Nme Setup RatteryPre 2 0 0 6 eue hatte Urra Pd alicia Welcome to the BatteryPro 2 36 Setup Wizard Application Installation Run the Setup File From the folder of the extracted BatteryPro installation files see Extracting the BatteryPro Package Files above Double click on the Setup BatteryPro 2 0 0 xx exe where xx is latest released version Application Installation Open File Windows may give a warning Click Run button or type r to continue Click Cancel or red X button to stop installation Welcome to Setup Wizard Click Next button or type n to continue EO alias Copyright Notice a RARA INDI TAPER Click Next button or type n to continue is r Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 41 InterMetro Industries Corporation Dll
60. tro Mobile Computing Workstations To remove the MPE 7800 Series Power Supply from the workstation base for replacement perform the following steps Notice Save all handle brackets screws and other hardware that are removed by this procedure for the replacement power supply to be mounted on the workstation If replacement hardware is needed please contact InterMetro Customer Service 1 Disconnect all cables DC Power connector RJ45 cable from the Gauge port USB from the USB B port and AC cable Remove the AC cable clamp from the ground stud on the back of the power supply 2 Remove the two 8 32 pan head screws from the workstation power supply mounts on each side 3 Facing the back of the workstation lift the power supply up to free the tabs from the slots on the mounts on the bottom of the workstation base Slide the handle brackets down the ramp of the mounts and lift out the power supply 4 Remove the three 8 32 pan head screws from each of the two handle brackets on each side of the power supply Notice The handle bracket hardware must be removed and the batteries must be disconnected before returning the power supply to InterMetro Industries Corporation 38 Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation Software Installation The BatteryPro software application installation file contains all drivers and applications for BatteryPro operation No
61. ts around the power supply case e Turn off computer equipment and then the power supply e Check that the fan is not blocked Check the ventilation slots around the power supply case for dust build up and clean e Turn on the power supply and restart the computer equipment e If this problem continues contact InterMetro Customer Service The following are the ways diagnostic information is provided by BatteryPro when it is installed and running BatteryPro will generate a popup message when a fault is detected The error may correspond to a Fuel Gauge warning shown above Carefully read the popup messages since they generally contain information giving a solution to the problem that occurs For additional information contact InterMetro Customer Service A Diagnostic tab is available in the BatteryPro dialog window Please see Diagnostics under BatteryPro Configuration and Status above BatteryPro generates a log stored at x Documents and Settings All Users Application Data BatteryPro Historylog txt where x is your main computer drive typically the C drive A fault code shows up in the log as Fault Code CMD 70 nn where nn is fault code number from 1 to 14 Notes on the fault may follow the fault number Examples Fault Code CMD 70 4 Battery Fuse Blown Fault Code CMD 70 14 Heatsink Overtemperature 62 Metro MPE 7800 Series NiMH Power Supply Operations Manual Su
62. ulations Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Regulatory Compliance This system was tested and complies with UL 60601 1 CAN CSA C22 22 No 601 1 and IEC EN 60601 1 1 medical safety standards Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 3 InterMetro Industries Corporation Symbol Explanations INTERME TARO INDUS TREES WILKES BARRE PA USA no MODEL MPE 7800 ns The product is CSA certified with respect to electrical shock fire and mechanical hazards only MEDICAL POWER ELECTRONICS 219 in accordance with UL 60601 1 CAN CSA C22 22 No 601 1 and IEC EN 60601 1 1 as Type B OUTPUT 10 5 16VDC 120W INPUT 100 240VAC 50 60Hz 5A C Patient Care Medical Equipment suitable for use in patient vicinity 400641 MADE IN USA li Attention consult accompanying documents Important Safety Instructions This document contains important safety and operating instructions for the MPE 7800 series Power Supply Please read all instructions and cautionary markings before putting it into service on a Mobile Computing Workstation gt pP amp gt amp Caution User maintenance consists of cleaning periodic tightening of fasteners and the like For safety purposes any and all servicing other th
63. ument is 402545 RevB 01 09 2013 Paul Prickett RevA MPE7800 NiMH PS Operations Manual 3 Updated references in Page 9 4 All above revisions remain valid in L01 504 RevA 6 Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation Table of Contents FRETEPENCOS AO o o escucel uecu ce unease a ARE ARE ARE E Lede ede 9 IR TOUUGHON SE Re en a nee ne ne ne cn 10 Mobile Rechargeable Power Supply ss 10 Power SUPPIY STATUS ere id 11 SAUS hs mena anne nr a FE ett e sd sen aN nn 12 Equipment Classification suisses 13 Important Product Notices hante a damien ste eta nd al a 13 DiSposalis rat en Ro save cans dde seine anti ere tendant nine net n nets le tan rats 1e See 13 NA MEE ME E E HEEE TE EE E Getting Started das 14 A a a ea a a a a r a a E 14 Charging the Power Supply Battery sise 14 Powering Up the MPE 7800 NiMH Power Supply esse 15 Starting Battery Pros iii A A A ad 16 Battery POSI A A at Asa 16 Terminating Battery Pro iii dd a ds Sess te eke ieee 17 a OPE AAA AAA E TE 18 Power Supply Location on the Metro Series Mobile Computing Workstation 18 Powering Up the MPE 7800 NiMH Power Supply iii 19 Remote Fu AU ida 19 Starting BatteryPro AppliC OM tata cxae todd net sent tres t du den tel ses due dt 22 BatteryPro Status Indications sise 23 BatteryPro Configuration and Status 27 8 _ ___ _____ ____ __a_ MPE 7800 Power Supply System Installation
64. us the percentage of charge in the batteries and remaining charge time to full charge Charging Power supply is plugged into AC power source and is charging the batteries Notice If message Communications Standby is displayed the power supply is not talking to the workstation computer See Troubleshooting below Discharging Full Level Power supply is not plugged into AC power and is running on batteries batteries near full charge Battery fill level is green Discharging Half Level Power supply is not plugged into AC Pa al power and is running on batteries batteries near half charge Battery fill level is green Discharging Y Level Power supply is not plugged into AC power and is running on batteries batteries near Y charge Battery fill level is yellow Notice A Low Battery Alert message may be displayed if battery charge has dropped below threshold set for Low Battery Alert see Alarms below Discharging Low Level Power supply is not plugged into AC power and is running on batteries batteries nearly discharged Battery fill level is red Notice A Critical Battery Alert message may be displayed if battery charge has dropped below threshold set for Critical Battery Alert see Alarms below Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 23 InterMetro Industries Corporation Desktop Status Window
65. where x is the main drive usually C drive Click Next button or type n to continue Hardware Installation Warning If you receive this warning Click Continue Anyway button or type c to continue Files Needed Wyse V90 or similar only During the installation process activity it may stop with the Files Needed warning shown The additional file serenum sys is required Click the Browse button Navigate to the folder of the extracted BatteryPro installation files see Extracting the BatteryPro Package Files above ge Click on the serenum sys extension sys may not 7 appear that is the type of file Windows is looking for Click Open button to continue 1 LEE Fmmmmmns Cou Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement Doc No L01 504 47 InterMetro Industries Corporation x Click OK button to continue o neir AN E Cancel Type the path hene the Hie ct ard then chek or Copy thes bom SE lf Completing Installation of USB Serial Port Completing the Found Now Hardware Wizard FACE After the brief activity screen the completion screen will conte appear Click on Finish button or press Enter key Settings for the Wyse V90 Series or Similar Thin Client Computer After completing the procedure above for USB Driver Installation perform the following s
66. y and not for general user 36 Metro MPE 7800 Series NiMH Power Supply Operations Manual Supplement InterMetro Industries Corporation MPE 7800 Power Supply System Installation In general the Metro MPE 7800 Series NiMH Power Supply is provided already installed on a Metro Mobile Computing Workstation and is ready for use The MPE 7800 Series NiMH Power Supply can be retrofitted replaced or installed new on a Metro Mobile Computing Workstation The power supply is self contained and is attached using the correct mounting hardware and cables on the bottom of the Metro Mobile Computing Workstation base For additional help contact InterMetro Customer Service Hardware Installation Notice The following mounting and removal procedures apply to the most recent version of the MPE 7800 Series Power Supply for the Metro Mobile Computing Workstations Older versions employ stud mounting slots on the top of the unit instead of the bracket system described below For additional information and help please contact InterMetro Customer Service Mounting the MPE 7800 Power Supply A Caution For safety only qualified service personnel should perform the following procedure to mount the MPE 7800 Series Power Supply on the Metro Mobile Computing Workstations To mount the MPE 7800 Series Power Supply to the workstation base as a new or replacement to an existing power supply perform the following steps Notice All
67. you use the power supply for the first time the NiMH cells should receive a full charge of at least 8 hours Break in The MPE 7800 NiMH Power Supply must undergo a break in period in order to realize the full battery capacity The break in period is usually the first 5 charge discharge cycles During the break in period the user may experience shorter runtimes than expected Charge cycle After the initial charge a completely discharged battery will quick charge in 3 to 3 5 hours to 95 of battery capacity At the end of quick charge all 5 amber LEDs will be illuminated and the green CH Charge LED will turn off At this point the batteries of the power supply are essentially charged and over the next 3 hours the power supply will slowly top off the batteries If the Mobile Computing Workstation will not be used for an extended period of time ensure the ON Extended Storage Switch is set to the Extended Storage OFF position If the power supply is left in the ON position the workstation equipment will continue to draw power and deep discharge the battery If the Mobile Computing Workstation is to be placed in long term storage longer than one week the Power Supply should be fully charged before placing the ON Extended Storage switch in the Extended Storage OFF position Warning Risk of Electric Shock The Power Supply employs a NiMH battery to provide mobile DC output power Low voltage 10 16 VDC
68. ystem Installation below Unpacking If ordered separately the MPE 7800 Series NiMH Power Supply will arrive fully assembled and fully functional at the customer s site in a cardboard box After cutting open the box lift the MPE 7800 out of the box Inspection After the MPE 7800 Series NiMH Power Supply has been unpacked the user should inspect the unit for any shipping damage If there is any damage please contact InterMetro Customer Service immediately Charging the Power Supply Battery Before placing a Metro Series Mobile Computing Workstation into service for the first time with the MPE 7800 Series NiMH Power Supply the power supply battery should be initially charged for a full 24 hours To charge the battery plug the coiled AC power cord into an AC outlet and put the ON Extended Storage Switch into the ON position see Powering Up the MPE 7800 NiMH Power Supply below For further information on the charge indicator lights of the Remote Fuel Gauge please refer to the Remote Fuel Gauge section below After the initial charge a completely discharged battery can fast charge in 3 to 3 5 hours to 95 of battery capacity and then top off the batteries within 3 more hours The MPE 7800 NiMH Power Supply must undergo a break in period in order to realize the full battery capacity The break in period is usually the first 5 charge discharge cycles During the break in period the user may experience shorter runtim