Home
Leica MATS
Contents
1. Leica MATS User manual English Leica MICROSYSTEMS Contents Page Description ri ole 3 Safely CONCEDE ccc cc issss a aa 4 Safety regulations 5 Assembly The components si 8 Installation seer age eins 10 Use Operating controls 2 na haw en age 12 Switching on and 13 Temperature control 13 Dimensions and weight 14 Technical data cece eee eee eee eee aes 16 Leica MATS Contents Description Purpose User manual MATS Microscope stage Automatic Thermocontrol System The Leica thermocontrol system MATS is a heating system for microscopes and stereomicroscopes and allows the viewing of sensitive microscopic specimens under accurate temperature conditions e The present user manual describes the assembly and operation of the Leica thermocontrol system MATS Your instrument is supplied with a printed user manual in English Additional languages and information can be found on the inter active CD ROM that is supplied with your Leica stereomicro scope or macroscope User manuals and updates are available for download on our homepage at www stereomicroscopy com Detailed information about the microscope stereomicroscope or macroscope can be found in the separate user manual to eac
2. When the key is pushed for 1 sec or more the indicated temperature changes continuously 2 seconds after above adjustment the temperature controller starts operating to obtain set tempera ture gt Set the temperature control to the desired temperature using the keys 2 gt Wait 10 minutes until the temperature of the thermoplate stabilizes Leica MATS Operation Dimensions and weight Control unit Weight about 1 3kg Dimensions width 113 mm length 210 mm height 128 74 mm Thermoplate 10 447 164 for Leica M stereomicroscope with transmitted light base HL Weight about 420 g Thermoplate 10 447 165 for Leica M stereomicroscope with transmitted light base lightfield darkfield Weight about 540 g Thermoplate 10 447 167 for inverted microscopes Leica DMIRB 3 plate x y stage Weight about 100 g Thermoplate 10 447 318 for inverted microscopes Leica DMIRB amp DMIL Weight about 80 g Thermoplate 10 447 312 for upright microscopes general Weight about 100 g Thermoplate 10 447 166 Weight about 300 g Thermoplate 10 447 275 Weight about 170 g 14 Leica MATS Dimensions and weight 10 447 164 265 174 257 10 447 165 10 447 167 132 150 Dimensions 150 10 447 318 g
3. general Thermoplate type 10 447 166 Thermoplate type 10 447 275 for Leica M stereomicroscopes with transmitted light base TL ST TL BFDF TL RC or TL RCITM Leica MATS Assembly 10 447 164 10 447 165 10 447 167 10 447 318 friiher 10 447 169 10 447 312 friiher 10 447 168 10 447 166 10 447 275 Leica MATS Assembly Assembly Thermoplate Fig 1 Fig 2 Fig 3 gt Remove the existing glass insert from the base of a stereomi croscope to reach the correct temperature gt Place the thermoplate on the object stage of the microscope stereomicroscope according to Fig 1 6 Heating stage 10 447 164 for Leica M stereomicroscopes with transmitted light base HL gt Tighten attachment screws on both sides of the thermoplate Heating stage 10 447 165 for Leica M stereomicroscopes with transmitted light base lightfield darkfield Heating stage 10 447 167 for inverted microscopes Leica DMIRB 3 plate x y stage Leica MARTS Installation Fig 4 Fig 5 Fig 6 Fig 7 Control units Heating stage 10 447 318 for inverted microscopes Leica DMIRB amp DMIL Heating stage 10 447 312 for upright microscopes general gt Attach heating stage with adapter according to the figure Heating stage 10 447 166 Heating stage 10 447 275 for Leica M stereomicroscopes with transmitted light base TL ST TL TL RCTM and TL RCITM
4. T actual temperature in the middle of the heating stage lies within a range of t gt T gt 1 1 C whereby t represents the settemperature under the condition that the set value t 37 C step 0 1 C setting method with Up and Down key setting range room temperature to 50 C achievable temperature accuracy 0 3 C with indicator temperature sensor thermocouple connection to heating stage 4 pole connector cable length 1000 mm instructions method 7 segment digital display and single lighting indicator step 0 1 C indicating accuracy 0 5 50 C within 10 minutes Leica MATS Technical Data Notes 18 Leica MATS User Manual Notes Leica MATS User Manual Leica Microsystems the brand for outstanding products Leica Microsystems mission is to be the world s first choice provider of innovative solutions to our customers needs for vision measurement and analysis of micro structures Leica the leading brand for microscopes and scientific instruments developed from five brand names all with a long tradition Wild Leitz Reichert Jung and Cambridge Instruments Yet Leica symbolizes innovation as well as tradition Leica Microsystems an international company with a strong network of customer services Australia Austria Canada Denmark France Germany Italy Japan Korea Netherlands People s Rep of China Port
5. gt Connect the thermoplate with the control unit gt Plug the power cable connector into the input receptacle of the heating unit Approved power cables see p 16 Leica MATS Installation 11 Use Operating controls 1 Power switch 2 Temperature control 3 Setting the temperaturs Up Down keys 4 PV display shows the process value and various symbols 5 SV display shows different settings values q gt La 12 Leica MATS Operation Switching on and off A Control of the Temperature Setting the temperature Before commissioning the Leica thermocontrol system MATS read the safety regulations on p 4 7 gt Press the power switch 1 gt When you finish operating turn off the power switch and disconnect the plug of power supply cord The thermoplate heating stage can be heated up to 50 C The process value displayed atthe control unit corresponds to the temperature of the table surface If the specimen in a petri dish or on a slide glass indicates a lower temperature com pared to the displayed process value adjust the set value to obtain a proper specimen temperature Otherwise the spec imen could be damaged e With stereomicroscopes it must be ensured that the I existing glass insert is removed from the base before the heating stage is placed Otherwise the correct tempera ture is not guaranteed To adjust the temperature press the Up Down keys
6. h instrument Leica MATS Description 3 Safety concept Legal requirements Conformity with European Community directive Permitted uses Prohibited uses Before assembling and commissioning the Leica thermocontrol system MATS read the present user manual and observe all safety notes Adhere to general and local regulations relating to accident prevention and environmental protection The Leica thermocontrol system MATS is constructed in accordance with the latest technologies and is provided with a statement of conformity with EC requirements The Leica thermocontrol system MATS is a heating system for microscopes and stereomicroscopes and intended for viewing sensitive microscopic specimens under accurate temperature conditions The thermoplate heating stage can be heated up to 50 C The Leica thermocontrol system MATS consists of a control unit a power cable and various thermoplate stage types for Leica stereomicroscopes transmitted light stands and micro scopes upright amp inverted Thermoplate and control unit are matched to each other e Always use thermoplate and control unit from the same I packaging never from different packagings If the Leica thermocontrol system MATS differently than described in this user manual it may lead to personal injuries or property damage Do not fit different plugs or cables e Do not change or convert the Leica thermocontrol system MATS D
7. o not dismantle any part of the motor focus system unless instructions for doing so are given in the user manual e The Leica thermocontrol system MATS may not be opened and maintained by unauthorized personnel Leica MATS Safety concept Safety regulations Place of use Temperature control Protective measures of the manufacturer The Leica thermocontrol system MATS may only be used in closed facilities The following installation sites must be excluded e Where flammable gas corrosive gas oil mist and particles that can deteriorate electrical insulation are generated or are abundant e Where highly intense vibration or impact is generated or transferred e Near high voltage power lines or where inductive interfer ence can affect the operation of the Leica thermocontrol system MATS e Sites which create condensation water or humidity or are exposed to direct sunlight The process value displayed at the control unit corresponds to the temperature of the table surface If the specimen in a petri dish or on a slide glass indicates a lower temperature compared to the displayed process value adjust the set value to obtain a proper specimen temperature Otherwise the specimen could be damaged If the sensor malfunctions the surface may become very hot e Dielectric strength 2 sec at 1350 V AC between power supply terminal and ground terminal e Insulation resistance 500 V Mega more than 100 MQ minimum between power
8. onmental management Winner 2005 Innovationspreis der deutschen Wirtschaft The World s First Innovation Award www leica microsystems com MATS The companies of the Leica Micro systems Group operate internationally in three business segments where we rank with the market leaders Microscopy Systems Our expertise in microscopy is the basis for all our solutions for visualization measurement and analysis of micro structures in life sciences and industry With confocal laser technology and image analysis systems we provide three dimensional viewing facilities and offer new solutions for cytogenetics pathology and materials sciences e Specimen Preparation We provide comprehensive systems and services for clinical histo and cytopathology applications biomedical research and industrial quality assur ance Our product range includes instruments systems and consumables for tissue infiltration and embedding microtomes and cryostats as well as automated stainers and coverslippers e Medical Equipment Innovative technologies in our surgical microscopes offer new therapeutic approaches in microsurgery eua MICROSYSTEMS ons and technical data are not binding and may be changed without notice M2 227 0en Leica Microsystems Switzerland Ltd CH 9435 Heerbrugg 2002 Printed in Switzerland 11 2006 RDV Illustrations descri
9. supply connection and ground connection e Fire protection Temperature cannot be set higher than 50 C e Fuse T AC250V 1 6 A e The Leica thermocontrol system MATS is electromagneti cally compatible in accordance with the directive 89 336 EEC and can be operated atthe same time as other electrical appliances Leica MATS Safety regulations Requirements for the user Repairs and servicing Power cable Liquids Ensure that e the Leica thermocontrol system MATS is operated main tained and repaired only by authorized and trained personnel the operating personnel has read and understood this user manual for the stereomicroscope or microscope and particu larly all safety regulations and applies them e Repairs may be performed only by service technicians trained by Leica Microsystems e Only original Leica Microsystems spare parts may be used e Disconnectthe power supply for maintenance and repair work otherwise there is a risk of injury through electric shock e Only use the power cables listed on page 16 e Inspect the power cable regularly for damage If it is defec tive replace it immediately because it could cause the instrument and ancillary equipment to become energized and thereby endangering personnel e Observe proper cable routing so that no one can become entangled in it or fall over it The instrument could tip over and be damaged e Avoid pulling at the power cable Be careful when handling liq
10. t 145 113 I ue T e SH i iJ o Y Le 165 gt LI 10 447 312 D 1 Y 10 447 166 I 3 180 E 205 7 10 447 275 Leica MATS Dimensions and weight 220 Technical Data Power supply Operating Environ mental Conditions Power cable Leica thermocontrol system MATS 100 240 V 10 AC 50 60 Hz 0 68 A protection class indoor use only temperature 5 C to 40 C maximum relative humidity 35 to 80 altitude up to 2000 m max environmental conditions installation category Il according to IEC 664 degree of pollution 2 For mains supplies with 100 to 120 V use only the following power cables UL listed detachable cord set 3 conductor grounding type SVT No 18 AWG rated at 125 V 7 A minimum if an extension cord is used use only a power supply cable with PE protective earth connector For mains supplies with 220 V to 240 V inside the EU use only 3 wire power cable plug and connector according to EU EN standards Class 1 equipment should be connected to PE protective earth terminal if an extension cord is used use only a power supply cable with PE protective earth connector Leica MATS Technical Data Control of the Temperature Temperature Indicator Duration method The temperature control is based on the PID controller with solid state relay achieved accuracy
11. ugal Singapore Spain Sweden Switzerland United Kingdom USA Gladesville Vienna Richmond Hill Ontario Herlev Rueil Malmaison Bensheim Milan Tokyo Seoul Rijswijk Hong Kong Lisbon Barcelona Sollentuna Glattbrugg Milton Keynes Bannockburn Illinois Tel 61 2 9879 9700 Tel 43 1 486 80 50 0 Tel 1 905 762 2000 Tel 45 4454 0101 Tel 33 1 47 32 85 85 Tel 49 6251 1360 Tel 39 0257 486 1 Tel 81 35421 2800 Tel 82 2 514 65 43 Tel 31 70 4132 100 Tel 852 2564 6699 Tel 351 21 388 9112 Tel 65 6779 7823 Tel 34 93 494 95 30 Tel 46 8 625 45 45 Tel 41 44 809 34 34 Tel 44 1908 246 246 Tel 1 847 405 0123 Fax 61 2 9817 8358 Fax 43 1 486 80 50 30 Fax 1 905 762 8937 Fax 45 4454 0111 Fax 33 1 47 32 85 86 Fax 49 6251 136 155 Fax 39 0257 40 3475 Fax 81 3 5421 2896 Fax 82 2 514 65 48 Fax 31 70 4132 109 Fax 852 2564 4163 Fax 351 21 385 4668 Fax 65 6773 0628 Fax 34 93 494 95 32 Fax 46 8 625 45 10 Fax 41 44 809 34 44 Fax 44 1908 609 992 Fax 1 847 405 0164 and representatives of Leica Microsystems in more than 100 countries In accordance with the ISO 9001 certificate Leica Microsystems Switzerland Ltd Business Unit Stereo amp Macroscope Systems has at its disposal a management system that meets the require ments of the international standard for quality management In addition production meets the requirements of the international standard ISO 14001 for envir
12. uids Spilled liquids on electrical devices can energize the instrument and ancillary equipment possibly causing personal injuries or damage to instruments Leica MATS Safety regulations Cleaning care Handle your Leica thermocontrol system MATS with care and avoid anything that may scratch the thermoplate e Disconnectthe power cable before cleaning the instrument e Never open or dismantle the control unit e Respectthe warning signs relating to the handling of liquids e Do not soak into water or into solvent e Never use any solvents such as gasoline or thinner to wipe the instrument The color of the surface could change or flake or imprinted characters could be removed e In case of dirt accumulation carefully clean the control I unit and thermoplate with a soft piece of cloth moistened with a solution of neutral cleaning agent dilluted in water Leica MATS Safety regulations Assembly The components 1 Control unit 2 Thermoplate 10 447 164 for Leica M stereomicroscopes with transmitted light base HL Thermoplate type 10 447 165 for Leica M stereomicroscopes with transmitted light base lightfield darkfield Thermoplate type 10 447 167 for inverted microscopes Leica DMIRB 3 plate x y stage Thermoplate type 10 447 318 previously 10 447 169 for inverted microscopes Leica DMIRB amp DMIL Thermoplate type 10 447 312 previously 10 447 168 with adapter for upright microscopes
Download Pdf Manuals
Related Search
Related Contents
La Crosse Technology WS-9009U User's Manual 掃除機のマニュアル Sony PEGA-WL100 User's Manual ATTENZIONE! - Campagnolo ソリック電子ドア 取扱説明書 円形式 DRタイプ 4” Submersible Petroleum and AG Pump - Veeder-Root Powermate PM0496504.18 Parts list Automação de Testes Baseados em Cenários com UML e WSP Quality Assurance Tool: Feedback Form Copyright © All rights reserved.