Home
PSU-S/H-12V/S-4A/8/FTA/PTC-MC PSDC08124
Contents
1. AUX8 outputs In case of loss of voltage on the output burnout of the fuse activation of the PTC appropriate LED diode stops to be illuminated L1 for AUX1 L2 for AUX2 etc e LED AW red diode indicates failure of at least one AUX output number of the output is signalled by the green diode OS 7 OS Pulsar Fig 4 View of the power supply panel 3 2 Technical output AW output signals the failure of the fuse output of the LB8 AW fuse block During the proper operation of LB8 AW fuse block AW technical output is on the mass potential whereas in case of damaging one of the fuses the output shall be disconnected from the mass Hi Z status This status is also signalled by the red Law diode on the LB8 AW fuse block 4 Service and operation 4 1 Procedure in case of short circuit SCP activity of the power supply output Outputs of the AUX1 AUX8 power supply of the LB8 AW fuse block are protected against short circuits with fuse element safety device inserts or PTC If fuse element safety device was chosen then in case of failure it is necessary to exchange the fuse element compliant with the original If PTC polymer fuses protection was chosen then automatic disconnection of the output voltage was signalled by switching off the green diode It is then necessary to disconnect the load from the power supply output for the period of about 1 min 4 2 Procedure in case of overload OLP activi
2. WWOEC Fig 3 View of the power supply 4 58mm 198mm 1 4 Technical parameters electrical parameters table3 mechanical parameters table4 user Safety table5 operation parameters table6 Electrical parameters table 3 60 ms 12 0V 15 0 V DC 5 5 1x P1 regulation LB8 AW fuse block 8 x F 0 5A fuse element safety device or PTC 1A or 4xF 1A fuses from the set Short circuit protection SCP POWER SUPPLY MODULE 110 150 of the power supply power electric current limitation automatic return after the failure has ceased 110 150 of the power power supply Overloading protection OLP electric current limitation automatic return after the failure has ceased 17 25 V 20 25V disconnecting the output voltage manual restoring disconnection of AC supply Technical outputs type OC 50mA max AW output signalling failure of fuse burning of the normal status L level 0 V LB8 AW fuse block activation of the SCP failure status hi Z level T 2 5A 250V F1 F4 fuse F 0 5A 250V or PTC 0 5A manual selection Mechanical parameters table 4 Casing dimensions 230 x 230 x 50 WxHxD with casing 235 x 235 x 58 Fixing Net gross weight Colour of the casing Closing Connections 230 V AC supply 0 63 2 05 AWG 22 12 Outputs 0 51 2 05 AWG 24 12 LB8 AW 00 51 2 05 AWG 24 12 Remarks The casing is equipped with distance from the mounting basis in order to guide the wiring system
3. Pulsar PSU S H 12V S 4A 8 FTA PTC MC PSDC08124 v 1 1 Stabilised impulse power supply unit Version 2 dated 18 01 2011 Replaces edition 1 dated 26 03 2010 Hee Ce CONTENTS 1 Technical description 1 1 General description 1 2 Block diagram 1 3 Description of elements and connectors of the power supply 1 4 Technical parameters 2 Installation 2 1 Requirements 2 2 Procedure of installation 3 Signalling the operation of power supply 3 1 Optical signalling 3 2 Technical output 4 Service and operation 4 1 Short circuit protection 4 2 Overload protection 4 3 Maintenance 1 Technical description 1 1 General description Stabilized power supply power supply is used for supply devices which require stabilised voltage of 12 V DC 12 0V 15 0V DC Basic features of the power supply 8 outputs protected independently with fuses F 500mA or PTC failure short circuit within the circuit of any of the outputs will result in burnout of the safety device insert or actuation of the PTC and isolation of the circuit from DC U supply optical work signalling informing about the condition of outputs and or failure AW technical output informing about output failure activity of the SCP used for remote control of the activity protection short circuit protection SCP overload protection OLP over voltage protection OVP regulation of the output voltage in case of installation where signifi
4. Warranty shall cover free repair or provision of functional equivalent the producer shall select the equivalent of the faulty device due to reasons lying in the domain of the producer including production and material faults unless these faults have been filed within the warranty period point 1 and 2 4 Device falling under warranty period should be delivered to the point where it was purchased or directly to the seat of the producer 5 Warranty covers complete devices with written description of the fault on properly filled claim application form 6 When a claim shall be positively considered the Producer shall be obliged to realise warranty repairs in the shortest possible time however this period of time should not extend 14 working days from the date when the device was delivered to the producer s service point 7 Repair period of which mention has been made in point 5 may be prolonged in case of lack of technical possibilities to perform the repair and in case of device conditionally accepted to the service point as the claimant did not meet the warranty conditions 8 All service activities resulting from the warranty shall be performed solely within the service point of the producer 9 Warranty does not cover faults of the device resulting from reasons not lying within the power of the producer mechanical failures improper storage and transport usage not compliant with the user manual or the anticipated use of the de
5. convection cooling User safety table 5 PN EN 60950 1 2004 protection class I first PN EN 60529 2002 U protection degree IP20 Insulation electric strength between the input network circuit and output circuits of the power supply I P O P 3000 V AC min between the input circuit and the PE protective circuit 1 P FG 1500 V AC min between the output circuit and the PE protective circuit O P FG 500 V AC min Insulation strength between the input circuit and the output or protective circuit 100 MQ 500 V DC Opaeration parameters table 6 Operating temperature 10 C 50 C Storing temperature 259C 60 C Relative humidity 10 90 without condensation 2 Installation 2 1 Requirements Stabilized power supply shall be mounted by the qualified installer having appropriate required and necessary for a given country permissions and qualifications for connecting operating 230V AC installations and low voltage installations The device should be mounted in closed rooms according to II environmental class with nominal air humidity RH 90 maximum without condensation and the scope of temperature within 10 C and 50 C table 6 The power supply should work in vertical position in order to ensure free convection airflow by ventilation holes in the casing Before installation is started the balance of the power supply load shall be performed During normal operation the sum of the c
6. cant drops in voltage in effective resistance of receiver supply cables can occur it is possible to correct the voltage value with the help of P1 potentiometer 12 0V 15 0V DC the power supply uses the modern module of the impulse power supply metal casing colour RAL 9003 with signalling panel Information about types Model Description PSDC 04122 Stabilised impulse power supply with overall current efficiency of 2A and output voltage of 12 PSU S H 12V S V DC Equipped with AUX1 AUX4 output condition signaling panel IP20 metal casing with 2A 4 FTA PTC MC Signaling panel equipped with TAMPER microswitch PSDC 04124 Stabilised impulse power supply with overall current efficiency of 4A and output voltage of 12 PSU S H 12V S V DC Equipped with AUX1 AUX4 output condition signaling panel IP20 metal casing with 4A 4 FTA PTC MC Signaling panel equipped with TAMPER microswitch PSDC 16128 Stabilised impulse power supply with overall current efficiency of 8A and output voltage of 12 PSU S H 12V S V DC Equipped with AUX1 AUX16 output condition signaling panel IP20 metal casing with 8A 16 FTA PTC MC signaling panel equipped with TAMPER microswitch 1 2 Block diagram fig 1 Fig 1 Block diagram of the power supply 2 1 3 Description of elements and connectors of the power supply table 1 table 2 fig 2 fig 3 L1 L8 green LED diodes signalling fuse activity O Bo o F1 F8 fuse element of safe
7. ower supply without the properly made and fully operational circuit of the shock protection is UNACCEPTABLE It can result in failure of devices and electric shock 5 Connect the cables of consumers to the AUX1 AUX8 terminals on LB8 AW fuse block with configuration of 8x0 5A 6 When necessary connect device cables alarm exchange controller signaller etc to technical outputs of the power supply AW LB8 AW output signalling the activity of the fuse output of the LB8 AW fuse block 7 In case of installation where significant drops in voltage in effective resistance of receiver supply cables can occur it is possible to correct the value of voltage with the help of P1 potentiometer 12 0V 15 0V DC P1 regulation of voltage in AUX1 AUX8 outputs 8 Place the fuse in the power circuit and connect the supply 9 Check optical signalling of the power supply operation 10 Close the casing after installing and verifying the correctness of the power supply activity 3 Signalling the operation of power supply The power supply is equipped with optical signalling the status of operation Presence of voltage on power supply outputs is signalled by illumination of green LED diodes on the frontal panel of the device Failure is signalled by red LED diode AW Condition of the power supply may be controlled remotely by AW technical output 3 1 Optical signaling fig 4 e LED L1 L8 green diodes signal the supply status on AUX1
8. ty of the power supply In case of loading the power supply with current exceeding 4A 110 150 P the output voltage shall be automatically disconnected automatic restoration after removing the failure overload 4 3 Procedure in case of initiation of OVP system of the power supply In case of initiating the OVP system it is necessary to disconnect the power supply from the network for about 1 minute 4 4 Maintenance All maintenance procedure may be performed after disconnecting the power supply from the power network The power supply unit does not require performing any special maintenance procedures however in case of significant drop of the dustiness it is only essential to remove the dust from the interior with the help of compressed air In case of changing the fuse it is essential to use substitutes compliant with the original parts WEEE MARKING The used electric and electronic device may not be thrown out together with common household wastes According to WEEE directive binding within the EU in case of used electric and electronic devices separate means of utilization should be utilized GENERAL WARRANTY CONDITIONS 1 Pulsar K Bogusz Sp j producer provides two year quality warranty for the device counting from the date of sale indicated on the bill of sale 2 In case when there is no bill of sale when filing the claim three year warranty period shall be counted from the date when the device was manufactured 3
9. ty devices in AUX circuits C s1 EN input of tne LB8 AW fuse block O wA AUX1 AUX8 outputs common COM clamp Element No Description Fig 2 Jumper of the change in PTC fuse element safety device type Fx FXx x Ey Fx jumper used polymer safety device selected Fx Fx x Ea Fx x jumper used fuse element safety device selected Table 1 LB8 AW elements fuse block 4mm een A AUX5 COM AUX6 COM AUX7 COM AUX8 COM COM IN eee eee NE i E _ _ _ _e Pd xK8 PTC fuse _ _ E5 2R3 fuse i LULW 6 7 F 1 F 4 fuse E it O z olo Z Ic z 2 Ao i I i y AUX1 COM AUX2 COM AUX3 COMAUX4 COM AW GND i 108mm 115mm PTC fuse nmm Fx 1 FXx 4 gt m Fig 2 View of the LB8 AW fuse block Fig 3 i L N connection of 230 V AC power supply PE protection connection F fuse in supply 230 V AC circuit P1 potentiometer regulating the output voltage LED optical signalling of the DC supply status main power supply module LB8 AW fuse block with supply outputs and optical signalling Table 2 Elements of the power supply O B o o POWER SUPPLY MODULE WLUGES
10. urrents consumed by the receivers cannot exceed I 4A P 60W max Because the power supply was designed for continuous work it is not equipped with supply switch hence it is essential to ensure proper overload protection in the supply circuit It is also necessary to inform the user about the manner of disconnecting the power supply from the network supply usually by isolating and determining proper fuse element in the fuse box Electric installation should be performed according to binding standards and regulations 2 2 Procedure of installation 1 Before initiating the installation it is necessary to ensure that the voltage in the 230 V power circuit is disconnected 2 Mount the power supply in the selected place and guide connecting conductors 3 Take off the fuse from power circuit 4 Connect the power cables 230 V AC with L N power supply terminals Connect the earth conductor to the clamp marked with earthing symbol The connection should be performed with 3 core cable with yellow green PE protecting conductor Power conductors should be connected to proper terminals through seal wire Power conductors should be connected to proper terminals through seal wire The circuit of the shock protection shall be performed with a particular care i e the yellow and green protection wire of the power cable shall be connected from one side to the terminal marked by the symbol of in the casing of the power supply Operation of the p
11. vice random events including atmospheric discharges power line failure fire flooding influence of high temperatures and chemical agents improper installation and set up not compliant with principles included in the user manual 10 Statement of performing changes in construction or repairs performed outside the service point of the producer or when the serial numbers or warranty stickers on the device were anyhow damaged shall result in the loss of warranty rights 11 Responsibility of the producer towards the purchaser shall limit to the value of the device settled according to the determined wholesale price suggested by the producer from the date of purchase 12 Producer shall bear no responsibility for faults resulting from damaging improper activity or impossibility to use the device especially when the above results from non observance of recommendations and requirements included in the user manual or use of the device Pulsar K Bogusz Sp j Registered partnership Siedlec 150 32 744 apczyca Poland Tel 48 14 610 19 40 Fax 48 14 610 19 50 e mail biuro pulsar pl sales pulsar p http www pulsar pl
Download Pdf Manuals
Related Search
Related Contents
File Tracking System User Manual Wiley Excel Data Analysis Requirements-Engineering und -Management Scarica manuale What if the calculation fails? Harmony XB5R - Expert Instruction Sheet - 01/2014 TEFAL RK400915 Instruction Manual E Conseil économique et social Gracias por adquirir un teléfono Sony Ericsson C905 Cyber RDM – Flexion Manuel d`utilisation Copyright © All rights reserved.