Home

Supervisor User Manual

image

Contents

1. To input the above login details use the scroll button to select the appropriate letter and press the scroll button to accept the letter This has to be done for each individual letter When the supervisor number SUPR has been inputted press F5 to toggle to the password box and again using the scroll button scroll to the appropriate number and press the scroll button to accept This has to be done for each number Press F5 to confirm the login details if they are correct a m will appear The screen should look like this ROMRQUIP AFLEET SUPERVISOR 22 4 ws000 7 16 5 1413 2 10 A p m o li actepr BACK If the details are correct press and hold F5 to login The vehicle number is also displayed The following screen will appear for a few seconds ROMRQUIP SUPERVISOR Login Successful PASSWORD Loading MAIN MENU HOLD xd ux is accept BACK RomaQuip Ltd Birr Co Offaly This shows log n was successful and settings are been loaded The main screen will appear ROMRQUIP MAIN MENU MOUNT BRINE TANK DEMOUNT UPLOAD FILLING ADJUST a DISPLAY LOGOUT SS m EUR This is the main gritting screen Login Complete If the login details are not inputted correctly The following screen will appear if either of the login details are incorrect ROMR UIP NOT RECOGNISED zz 2 1lo Als c o E F m tie The example above shows the Supervisor Number SU
2. Im 2 1 0 A B C D EF Pre HOLD definea im gt Ple BACK Routes ACCEPT As you are already logged in as a fleet supervisor it will be shown here Press F1 to see the predefined routes already set up The following screen appears RomaQuip Ltd Birr Co Offaly ROMRK UIP ROUTE SELECT Route Selected iu Al l l ACCEPT Using the scroll button scroll to the desired route and press the scroll button to select amp F1 to accept For example we will select R004 The following screen will then appear ROMREUIP mame A FLEET SUPERVISOR R00 4 M i2 1 0 A B C D E F Pre HOLD gail defined x Fs BACK Routes ACCEPT Press F5 to accept new route Press amp hold F5 to login new route If a valid route number has been entered the following screen will appear You can then let go of the F5 Button ROMRQUIP SUPERVISOR a ee Valid route ROUTE HUMBER entered Loading Gritting Screen oe l s Routes This screen will appear for a few seconds before reverting back to the main spreading screen RomaQuip Ltd Birr Co Offaly ROMK UIP DTH Hard Shoulder Off t Ogm RATE DEFAULT Lane 2 LSD 4 BLAST ON OFF Deflector FUSUGH Gyiorr MEHU Press F5 to start spreading The red ring on the spread on off icon will turn green To pause the gritting spreading press F5 the following screen will appear The rear beacons will illuminate when spre
3. PRINT DOWNLOAD MODEM SETTINGS DATA RS232 Not Acknowledged n li RS232 Timeout RS232 Error Back MAIH MEHU All the boxes are shown as Mf indicating all the information is been received amp the RS232 connector is working correctly RomaQuip Ltd Birr Co Offaly ROMRQUIP DATALOGGING CLEAR CHECK MEMORY MEMORY STATUS SET DATALOGGING GPS SETTINGS MODE PRINT DOWNLOAD MODEM SETTINGS DATA RS232 Not Acknowledged RS232 Timeout x gi al RS232 Error The red box is highlighting clear memory press the scroll button to enter the settings The following screen will appear ROMK amp LIP DELETE ALL DATALOGGING YES BACK MAM To delete the entire data highlight YES with the red box and press and hold the scroll button until the message deleting datalogging appears Data will then be deleted If you do not wish to delete the stored data using the scroll button highlight the NO option and press and hold the scroll button Press F5 to return to the main datalogging menu RomaQuip Ltd Birr Co Offaly 4 ROMR UIP DATALOGGING CLEAR CHECK MEMORY MEMORY STATUS SET DATALOGGIHG GPS SETTINGS MODE PRINT DOWNHLOAD MODEM SE DATA TTINGS RS232 Not Acknowledged RS232 Timeout gi al RS232 Error BACK MAIN Using the scroll button scroll to Check Memory Status Press there scroll button to enter the settings ROMAQUIP PCMCIA Ready Total Filesize 0 00 MB MEMORY STATUS
4. ROMKQUIP ts Fleet Supervisor User Manuals Road Maintenance Manufacturers Syngefield Industrial Estate Birr Co Offaly Ireland Tel 05791 20836 Fax 05791 21084 E Mail info romaquip com Web www romaquip com RomaQuip Ltd Birr Co Offaly Contents Login Datalogging Setup 4 Spreader Settings Setup Alarms Edit Drivers Edit Routes amp Clock Setup Spread Mount Demount Plough Unloading The Gritter Brine Tank Filling Material Calibration 3 Adjust Display End Route Lights amp Logout RomaQuip Ltd Birr Co Offaly LOGIN Note When using the scroll button to scroll to a desired setting a red box will indicate which setting is currently been highlighted LOGIN TYPE R FACTORY Scroll Button The above screen shows the main login screen this will be displayed a few seconds after the ignition is switched on Firstly the loading screen will appear then the main login screen The reset switch has to be pressed first before login can commence The reset switch is located at the left side of the box Spread Rate switch works on any page as long as you are logged in To login as a supervisor scroll to FLEET SUPERVISOR using the scroll button and press the scroll button to accept The following screen will appear RomaQuip Ltd Birr Co Offaly ROMRQUIP CUED Led a ws000 1 0 A BIC DIE FIG Password 1234
5. d lt MAIH BACK MEHU If this screen appears no PCMCIA card has been inserted into the PDM card slot on the PDM screen Before any data 1s entered a PCMCIA card has to be inserted This 1s to be done immediately If the PCMCIA card is inserted the following screen will appear RomaQuip Ltd Birr Co Offaly 5 ROMRAQUIP PCMCIA Ready Total Filesize 0 00 MB MEMORY STATUS BACK MENU This screen shows that the PCMCIA Memory card is inserted card found and ready for files to be saved to it The total file size shows the size of all files combined currently saved on the card The card has a total capacity of 1GB Press F5 to return to the main datalogging menu ROMR UIP DATALOGGING CLEAR CHECK MEMORY MEMORY STATUS SET DATALOGGING GPS SETTINGS MODE PRINT DOWHLOAD MODEM SETTINGS DATA RS232 Not Acknowledged J ll RS232 Timeout RS232 Error BACK MAIH MEHU Using the scroll button scroll too set datalogging mode and press the scroll button to enter the settings The following screen will appear RomaQuip Ltd Birr Co Offaly 6 ROMRSUIP SET DATALOGGING MODE BACK MA Here the current datalogging mode is shown on the top To change this mode use the scroll button to scroll between the different mode time event distance amp event time amp event and off To select the desired mode press the scroll button the new mode will now be displayed in the current dat
6. OFF E 15s SPREAD 7 SYMM Font ON OFF MEHU The illustration will show the plough been moved to the transport position This screen will disappear after a few seconds and the spreading screen will appear ROMRQUIP 20 1 12009 16 06 SPREADING OFF 8 m DATA LOGGING OFF LS lt TFF MAIH SYMM ior OH OFF MEHU To start spreading press F5 The following screen will appear ROMRQUIP 20 1 12009 16 17 perg LL EH a DA TALOGGING OFF SPREAD PRESS 2 to enter route number OH OFF and start datalogging i Mor Uo ERN Se 1 3 r st 4 WIDTH BLAST FLOAT ON OFF MEHU Press the start spread button F5 again to enter a route The following screen will appear RomaQuip Ltd Birr Co Offaly 12 SUPERVISOR HMURIBEH SUPR A FLEET SUPERVISOR lO i2 1 0 A B C D E F Pre HOLD i defined im gt Mi BACK Routes ACCEPT As you are already logged in as a fleet supervisor it will be shown here Press F1 to see the predefined routes already set up The following screen appears ROMRQUIP ROUTE SELECT Route Selected SIT y ACCEPT Using the scroll button scroll to the desired route and press F1 to accept For example we will select ROOA The following screen will then appear ROMR U T name A FLEET SUPERVISOR CE 2 1 0 A B C D E F HOLD Pre el defined im d Pa BACK Routes ACCEPT Press amp hold F5 to accept the
7. MEHU This screen shows the spread width driving lane rate of salt To set up these values the switches on the box will have to be used See next page for example RomaQuip Ltd Birr Co Offaly AULT Lane 1 Jr Spar BLAST ON OFEDeflettor Fin OFF BAEHU The picture above shows the PDM screen and Box mounted in the Cab of the truck On the bottom of the picture we have 4 switches for Spread width Driving Lane Spread Rate amp Hard Shoulder these switches control the inputs for the values that appear on the screen The example shown above shows the spread width 2 which is 1 lane the hard shoulder is on the driving lane is Lane 1 with the spread rate at 15g m2 The illustration on the right will show which lane the lorry is driving in and how many lanes it is spreading too Any changes made on the switches will be reflected on the screen The switches are all rotary switches except for the hard shoulder which is an illuminated Green push button switch RomaQuip Ltd Birr Co Offaly ROMR UIP DTH Hard Shoulder Off Ogi RATE DEFAULT Lane 2 BRIHE LS fos 4l MAIH Deflector LOUGH MEHU Going back to the first screen that is shown when you enter the spread settings When the hard shoulder button is presses the hard shoulder icon will turn green F3 can be used to move the plough deflector UP amp DOWN Press F2 to turn the brine on or off as required Press amp hold F4
8. route number If a valid route number has been entered the following screen will appear You can then let go of the F5 Button RomaQuip Ltd Birr Co Offaly 13 ROMR UIP ENCCHI Valid route entered Loue Gritting Screen gU Routes This screen will appear for a split second before reverting back to the main spreading screen ROMARQUIP 20 1 12009 16 22 SPREADING OFF DATA LOGGING ON ep Ios SPREAD J FLOAT ON OFF MEHU Datalogging is now enabled this is shown on the top of the illustration as ON in green To start spread press F5 Spreading is now ON To stop the spreading press F5 The following screen appears ROMARQUIP 20 1 2009 16 26 GRITTING PAUSED SPREAD PRESS 5 to resume spreading OH OFF SPREAD Press and HOLD to end route OH OFF 2 TIO Sa RATE PLOUGH WIDTH gast 27MM FLoaTt onorr MENU To resume spreading press F5 again or to end the route press and hold F5 When the route is ended the following screen will appear RomaQuip Ltd Birr Co Offaly 14 ROMR UIP 207 1 12009 16 27 All datalogging is stopped and gritting will stop The main spreading screen will appear again ROMAGUIP 20i 1 2009 16 28 SPREADING OFF DATA LOGGING OFF MAIH OH OFF MEHU Other information included on this screen includes The current speed of the lorry in km h Gate open or closed Liquid on or off What state the plough 1s in either flo
9. screen will appear RomaQuip Ltd Birr Co Offaly ROMRQUIP Float Plough Bolts PLOUGH Rose s CEN ON OFF After pressing the scroll button the icons on the bottom of the screen will change Press amp hold F2 to rotate left amp F3 to rotate right The plough on the right of the screen will change position i e left or right Press amp hold F5 to raise the plough On the deflection screen 1 e the first screen that appears when you enter the mount demount mode if the float is activated 1 e ON and you then toggle to the deflection screen by pressing the scroll button the following screen will appear ROMR UIP Plough Bolts Float lt OH OFF MEHU The icons for the left and right rotation of the plough are not visible The plough cannot be rotated left or right while the plough is in float mode To raise the plough press amp hold F5 The following screen will appear RomaQuip Ltd Birr Co Offaly ROMK amp L IP Plough Bolts Float som jos MEHU OH OFF The icons for rotating the plough left and right re appear and the float is indicated as OFF To return to the main Menu press F6 RomaQuip Ltd Birr Co Offaly 4 ROMKQUIP is User Manual Unload UNLOAD Note When using the scroll button to scroll to a desired setting a red box will indicate which setting s currently been highlighted ROMRQUIP MAIN MENU MOUNT BRINE TAHK D
10. the Set Moisture Rate icon is highlighted To enter the Set Moisture Rate Press the scroll switch Moisture Rate C t ET 0 Liquid B i BACK AERE The current value to shown at the top of the screen ORomaQuip Ltd Birr Co Offaly Use the scroll button to select the of liquid brine required and press the scroll button to accept The new value will be displayed on the top of the screen Press F5 to return to the main spreader settings screen ROMPF LIP SPREADER SETTINGS EDIT MATERIAL PARAMETERS SET TEST SPEED SET BUZZER MODE SET MOISTURE RATE EDIT LIGUIO PARAMETERS SET LIQUIO ONLY PRINT CURRENT SETTINGS Rotate the scroll switch until the Edit Liquid Parameters icon is highlighted To enter the Edit Liquid Parameters Press the scroll switch ROMASIENF EDIT LIQUID PARAMETERS Current Liquid Density MAH MEHU The current liquid density is displayed at the top of the page To enter new values Press F4 to highlight the required box and use the scroll button to select the new value When the desired value is inputted press the scroll button to accept When the new value have been accepted the New liquid density will be calculated automatically and displayed on the top of the screen Pres F5 to return to the main spreader settings screen ROMR LIP SPREADER SETTINGS SET TEST SPEED SET BUZZER MODE SET MOISTURE RATE EDIT LIQUID PORAMETE RS SET LIQUIO ONLY PRINT CURRENT SETTINGS Rotate th
11. to put the plough into the float position when you do this the following screen will appear Float can only be enabled when the lorry is traveling under 30km h JWI Hard em Off 0 g m 3 DEFAULT Lane 2 BRINE SPREAD t ODIS A MAIH BLAST onjorr Deflector GAUCH niorr MEHU The illustration shows the plough been put into the float position This screen will be flashed up for 5 seconds to show the plough moving into the float position before reverting back to the main spreading screen Press F5 to raise the plough into its original position The following screen will appear p Hard Sm Off Am 0 g m E DEFAULT Lane 2 BRIHE st D i 3 Deflector FLOUCH MEHU The illustration shows the plough been raised This screen will be flashed up for 5 seconds to show the plough been raised before reverting back to the main spreading screen RomaQuip Ltd Birr Co Offaly 4 auc Hard 0m Off 0 gim DEFAULT US 4 MAIN a o Deflector FLOUCH o MENU After all settings have been inputted press F5 to turn on the spreading The following screen will appear ROMRQUIP DATALOGGING OFF SPREAD PRESS X to enter route number ON OFF and start datalogging Os ols BLAST on OFF Deflector FUOUGH oniorr MENU Press the start spread button F5 again to enter a route The following screen will appear ROMRQUIP A FLEET SUPERVISOR
12. 20rpm To return to the main menu press F6 RomaQuip Ltd Birr Co Offaly ROMKQUIP ts User Manual Fleet Supervisor SETUP Datalogging Datalogging Note When using the scroll button to scroll to a desired setting a red box will indicate which setting 1s currently been highlighted ROMKQUIP MAIN MENU MOUNT BRIHE TANK DEMOUHT UPLOAD f FILLING LOGOUT Using the scroll button scroll to SETUP The screen below will appear ROMK amp LIP SETUP Datalogging spreader Settings Edit Drivers Edit Routes Using the scroll button scroll to Datalogging The screen below will appear RomaQuip Ltd Birr Co Offaly ROMKG amp LIP DATALOGGING CLEAR CHECK MEMORY MEMORY STATUS SET DATALOGGING GPS SETTINGS MODE PRINT DOWNLOAD MODEM SE DATA TTINGS RS232 Not Acknowledged RS232 Timeout i d RS232 Error BACK MAIN On the bottom left of the screen the RS232 signals are shown There is no RS232 error as indicated with EM if there was an error it would be indicated with E If the receiver has a problem with receiving data it will be indicated with Bill in the RS232 Not acknowledged box If the receiver is not responding to the data it will be indicated with Bl in the RS232 Timeout box If all the information 1s been sent and received correctly the following screen will appear ROMR UIP DATALOGGING CLEAR CHECK MEMORY MEMORY STATUS SET DATALOGGING GPS SETTINGS MODE
13. ARINF BRINE MEHU The information stored here is what has been inputted in the spreader settings in the setup For example 1f a test speed of 40km h has been set in the spreader settings it will show here under test speed 40km h The same applies for all other settings including spread rate which is set using the switch on the box when in the main spread screen on the example above the spread is 1 lane and the hard shoulder The gate height is the height the gate is currently set at To charge the belt press the F2 button the belt charges for 30 seconds This runs the belt for 30 seconds to bring the salt to the end of the belt To set the calibration for the brine use the scroll button to select the required time in seconds needed to calibrate and press F4 to calibrate To add 10 seconds to the calibration time press the scroll button F5 resets the calibration RomaQuip Ltd Birr Co Offaly 2 This symbol is just showing that right F2 controls the salt and left F4 controls the brine The material calibration can only be done under factory settings or by a fleet supervisor A driver does not have access to this screen Material Calibration complete press F6 to return to the main menu RomaQuip Ltd Birr Co Offaly 3 ROMKQUIP De N User Manual Adiust Display End Route Lights amp Logout ADJUST DISPLAY Note When using the scroll button to scroll to a desired setting a red box will in
14. EMOUNT UNLOAD f FILLING ADJUST DISPLAY Using the scroll button scroll to UNLOAD Press the scroll button to select The screen below will appear ROMRQUIP UNLOAD GRITTER PLEASE ENSURE THE FOLLOWING af Spreading has been Turned Off W The Vehicle is stopped El The Spinner Assembly is Folded Forward untold spinner to use spin unload Press to empty the spreader y EMPTY MEHU MAIH This screen will display the options to unload the gritter On the example above spreading s turned off and the vehicle is stopped this 1s indicated by the in the box However the spinner assembly is still folded forward i e in the spinner ready position In order to empty the spreader the spinner assembly will have to be pushed in when this is done the will appear in the box When all boxes are marked with the gritter can be emptied by pressing the F5 button The following screen will appear RomaQuip Ltd Birr Co Offaly 2 ROMR UIP UNLOAD GRITTER PLEASE ENSURE THE FOLLOWING if Spreading has been Turned Off The Vehicle is stopped x The Spinner Assembly is Folded Forward untold spinner to use spin unload Press to empty the spreader The gritter has started to unload the salt To stop unloading the press F5 When using this option the salt will be dumped directly out of the chute Alternately a spin unload can be done by pressing F1 This allows the salt to be dumped from the gritter via the spi
15. ND ROUTE ROMK UIP MAIN MENU MOUNT BRINE TAHK DEMOUNT UNLOAD Fei inc LOGOUT Using the scroll button scroll to END ROUTE Press the scroll button to accept The following screen will appear ROMKG amp UIP MAIN MENU DATALOGGING STOPPED When a route is entered in the spreading screen see spread manual for info it can be ended by scrolling to end route on the main screen then press the scroll button to end the route The above screen will appear for 5 seconds before reverting back tot the main screen thus the route has ended and all datalogging has stopped RomaQuip Ltd Birr Co Offaly 4 LIGHTS ROMK amp UIP MAIN MENU BRINE TAHK FILLING N LOGOUT Using the scroll button scroll to LIGHTS Press the scroll button to accept The following screen will appear ROMR UIP LIGHTING LOADING LIGHT BEACONS This screen displays the lights that can be manually switched on Press F3 to switch on the loading light amp press F4 to switch on the beacons When both of these a switched on the following screen will appear RomaQuip Ltd Birr Co Offaly ROMKG amp UIP LIGHTING LOADING LIGHT BEACONS When each light is switched on the screen will show them illuminated The loading light is indicated with the yellow beam and the beacons are showing flashing Always check and see if the lights are working on the lorry Press F6 to return to the main screen RomaQu
16. PS which is not recognized To change this press F5 to toggle to the supervisor number box Press F2 or F3 to move the cursor to the letter that needs to be changed then using the scroll button select the correct letter and press the scroll button to accept Press F5 to login RomaQuip Ltd Birr Co Offaly Information ROMR UIP MAIN MENU MOUNT BRINE TANK DEMOUHT UNLOAD p FILLING LOGOUT When on the main menu screen above press and hold F1 amp F2 Simultaneously The following screen will appear ROMAQUIP SPREAD VARIABLES Gate CYL Voltage OmV 160 8 mm Chute CYL Voltage OmV R required speed d A actual speed MAIN MEHU This screen will display all the spread variables such as the belt amp spinner speeds R Required Speed A Actual Speed I Current RomaQuip Ltd Birr Co Offaly ROMRQ UIP SPREAD VARIABLES Gate CYL Voltage 3858mV Chute CYL Voltage 6127mV R required speed il actual speed MAIH MEHU The example above shows the variables with the truck traveling at 40km h with the gritter spreading 2 lanes and hard shoulder Sp Width 9 2m driving n lane 2 with the spread width Sp Rate at 308 m The Gate cylinder s set to 98 3mm and the chute cylinder 1s set too 61 3mm this is set automatically depending on the spread pattern required The spinner fro example is giving a feedback current of 804Ma the required speed is 322rpm amp the actual spinner rpm is 3
17. Screen Press the scroll switch ROMREUIP LOCK SPREAD WIDTH u STATUS UNLOCKED agli BACH MEHL MAI Press F1 to lock Unlock the Spread Width Press F5 to go back to the spreader settings screen RomaQuip Ltd Birr Co Offaly ROMR UIP SPREADER SETTINGS EDIT MATERIAL PARAMETERS SET TEST SPEED SET BUZZER MODE SET MOISTURE RATE EDIT LIGUID PARAMETERS SET LIQUID ONLY PRINT CURRENT SETTINGS Rotate the scroll switch until the Lock Spread Pattern icon is highlighted To enter the Lock Spread Pattern Screen Press the scroll switch ROMRGUIP LOCK SPREAD PATTERN on STATUS UNLOCKED LOCK BACK MEHU Press F1 to lock Unlock the Spread Width Press F5 to go back to the spreader settings screen ROMAGUIP SPREADER SETTINGS Rotate the scroll switch until the Activate snow setting icon is highlighted To enter the activate snow setting Screen Press the scroll switch ROMRQUIP Snow Setting Current setting MAIH BACK MEHU The current setting is shown on the top of the screen To change this use the scroll button to select and press the scroll button to accept new setting Press F5 to return to the main spreader settings screen RomaQuip Ltd Birr Co Offaly ROMR LIP SPREADER SETTINGS SET TEST SPEED SET BUZZER MODE SET MOISTURE RATE EDIT LIQUID PORAMETE RS SET LIQUIO ONLY PRINT CURRENT SETTINGS Rotate the scroll switch until the Set spread width range icon is highligh
18. TS L OEMOUNTE UNLOAD f FILLING D SETUP MATERIAL H ADJUST CALIB ROUTE DISPLAY LOGOUT I E o R Select setup from the main menu screen using the scroll switch ROMRGUIP SETUP Using the scroll button select Alarms and press the scroll button to accept The following screen will appear ROME ALARMS LIST Alarm No Speed Signal 0 Spinner Signal O0 Bektsigna o Brine Signal oO 0 FilterfOilLevel 0 10 Hydraulic Valve RESET s I X HOLD BACK This screen will display all the alarms that have been created including the date and time of each alarm and how many times it was acknowledged accepted Use the F4 button to scroll down through the list and F5 to scroll back up the list To reset the alarms press and hold the FI button Press F6 to return to the main setup screen RomaQuip Ltd Birr Co Offaly ROMPE SETUP Datalogging Spreader Settings Edit Drivers Edit Routes Using the scroll button select Edit Drivers and press the scroll button to accept The following screen will appear EDIT DRIVERS i MAIH BACK MEHU Here the list of drivers 0001 to 0012 will be displayed to scroll between then use the scroll button to accept the new driver number press the scroll button Press F5 to return to the main setup screen ROMK amp LIP SETUP Datalogging spreader Settings Edit Drivers Edit Routes Using the scroll button select Edit Routes and pres
19. ading begins when spreading is either stopped or paused beacons will stop ROMR UIP GRITTING PAUSED SPREAD PRESS to resume spreading OH OFF SPREAD Press and HOLD to end route OH OFF st ts SPREAD al BLAST OH OFF Deflector LOUGH owe MENU When gritting s paused rear beacons will stop amp gate remains open Note Spinner stays on for three seconds after spreading paused or stopped To resume spreading press F5 to end route and stop datalogging press and hold F5 the following screen will appear MAIN MEHU All datalogging is stopped and gritting will stop RomaQuip Ltd Birr Co Offaly The main spreading screen will appear again ROMKQUIP DTH Hard Shoulder Off 0 gin RATE DEFAULT Lane 2 BRIHE OS t yst 4l MAIH 3 Deflector PLOUGH 9o MEHU While a route is logged in Spreading is on and datalogging is running a blast of salt can be sent through the spinner assembly by pressing amp holding Fl When pressing F1 the simulated speed is set to 40km h which sets off the spot blast The screen should look like this until Fl 1s released ROMR UIP m WIDTH Hard Shoulder Off SPOT BLAST Lane 2 BRIHE US DS d 5 MA 3 o Deflector PLOUGH o MEHU Spot blast is shown on the screen Release Fl and the screen will return to the main spreading screen The spot blast can only be used if the truck 1s running between 0 IOkm h If the truck is
20. alogging mode Press F5 to return to the main Datalogging menu Datalogging now completed press F6 to return to the main menu RomaQuip Ltd Birr Co Offaly ROMKQUIP is User Manual Fleet Supervisor SETUP Spreader Settings Spreader Settings Note When using the scroll button to scroll to a desired setting a red box will indicate which setting 1s currently been highlighted MAIN MENU MOUNT BRINE TANK DEMOUHT UNLOAD f FILLING LOGOUT Select setup from the main menu screen using the scroll switch ROMRGUIP SETUP Clock Select the Spreader Settings icon from the setup screen using the scroll switch ROMAGLIP SPREADER SETTINGS EDIT MATERIAL PARAMETERS SET TEST SPEED SET BUZZER MODE SET MOISTURE RATE EDIT LIGUID PARAMETERS SET LIQUID ONLY PRINT CURRENT SETTINGS Use the scroll switch to select the variable that you want change To enter the Set Material screen highlight the icon on the screen by rotating the scroll switch then press the scroll switch to enter the screen RomaQuip Ltd Birr Co Offaly Current Material SALT 1 Rotate the scroll switch to select the type of material you want to use To enter the material as the default material press the scroll switch ROMR QUIP SPREADER SETTINGS SET MATERIAL EDIT MATERIAL PARAMETERS LOCK SPREAD RATE LOCK SPREAD WIDTH Rotate the scroll switch until the Edit Material Parameters icon is highlighted To enter the E
21. alue The new value will now be shown at the top of the screen Press F5 to return to the main spreader settings screen ROMR LIP SPREADER SETTINGS LOCK SPREAD RATE LOCK SPREAD PATTERN SET SPREAD WIDTH RANGE SET BLAST RATE SET TEST SPEED SET MOISTURE RATE Rotate the scroll switch until the Set Max Spreading Speed icon is highlighted To enter the Set Max Spreading Speed Screen Press the scroll switch ROMRGLNP Overspeed Value Cc t ae 120 km h S A BACK en The current Speed value 1s shown at the top of the screen To change this use the scroll button to select a new value press the scroll button to accept the new value The new value will now be shown at the top of the screen ORomaQuip Ltd Birr Co Offaly Press F5 to return to the main spreader settings screen ROMPF LIP SPREADER SETTINGS SET TEST SPEED SET BUZZER MODE SET MOISTURE RATE EDIT LIQUID PARAMETERS SET LIQUIO ONLY PRINT CURRENT SETTINGS Rotate the scroll switch until the Set Buzzer Mode icon is highlighted To enter the Set Buzzer Mode Press the scroll switch Buzzer Mode Current Setting The current buzzer setting is displayed on the top of the screen Use the scroll button to select a new setting on OR off press the scroll button to accept The new value will be displayed on the top of the page Press F5 to return to the main spreader settings menu ROMR LIP SPREADER SETTINGS Rotate the scroll switch until
22. at or transport RST Road surface Temperature The sensor mounted on the front of the lorry measures this and it 1s displayed here Press F6 to return to the main screen RomaQuip Ltd Birr Co Offaly 15 Note een ALARM AE gim Access Ladders are not 3 DEFAULT folded up Lane 2 BRIHE DN SPREAD i MAIH 3 Deflector FLOUGH MEHU If this alarm pops up on the spreading screen the access ladders are to be folded up for spreading to commence RomaQuip Ltd Birr Co Offaly 16 ROMKQUIP is User Manual Plough Mount Demount Ploush Mount Demount Note When using the scroll button to scroll to a desired setting a red box will indicate which setting s currently been highlighted ROMRQUIP MAIN MENU MOUNT BRIHE TANK DEMOUHT UPLOAD f FILLING LOGOUT Using the scroll button scroll to MOUNT DEMOUNT The screen below will appear ROMRQUIP Plough Bolts TEE Float OFF DS DST TES d OH OFF Deflector Deflector Transport Float MEHU The deflector screen appears Ensure the plough bolts are in place this will be indicated by plough bolts ON Press F1 to turn on the plough Press amp hold F2 F3 for deflector UP or DOWN To put the plough into transport position press amp hold F4 To put the plough into float mode press F5 this will be indicated by the float ON To toggle to the plough rotation screen press the scroll button The following
23. dicate which setting 1s currently been highlighted ROMRQUIP MAIN MENU Using the scroll button scroll to Adjust Display Press the scroll button to accept The following screen will appear ROMR UIP ADJUST DISPLAY Set Brightness set Dim Brightness set Dimming Delay LED Button Lights LED Brightness ER ME NP This screen will display the display settings Set brightness corresponds to the brightness of the screen The dim brightness is the brightness that the PDM screen resets itself too after a period of time which is set under dimming delay LED button lights are the LED s Light Emitting Diode which light up under buttons F1 F2 F3 F4 F5 amp F6 The brightness for these is controlled under the LED Brightness setting To change any of these settings use F4 or F5 to select and the scroll button to select the desired setting NOTE If the LED Button lights are set of OFF the LED Brightness cannot be used RomaQuip Ltd Birr Co Offaly 2 ROMR UIP ADJUST DISPLAY set Brightness set Dim Brightness set Dimming Delay 80s LED Button Lights LED Brightness eee AE tls The example above show the brightness of the screen at 100 but after a period of 30s 30Seconds the screen brightness will become 90 The LED button lights are set to ON and there brightness is 10 Press F6 when desired settings are inputted the main screen will appear RomaQuip Ltd Birr Co Offaly 3 E
24. dit Material Parameters Screen Press the scroll switch EDIT MATERIAL PARAMETERS SALT 1 l MAIN BACK MEHU Rotate the scroll switch to set the material parameters Press the scroll switch when the correct material parameters are displayed AEN EDIT MATERIAL ROMA LU PARAMETERS MATERIAL HAME CONVEYOR CALIBRATION F M aterial PINHER parameters CALIBRATION F saved BRIHE PUMP CALIBRATIOH F Forwarding v ACCEPT BACK Rotate the scroll switch to set the material name use F1 to change from letters to numbers Press F2 to move the select box to the left Press F3 to move the select box to the right Press amp hold F5 to accept the material name Press F6 to go back to the main menu ORomaQuip Ltd Birr Co Offaly ROMR UIP SPREADER SETTINGS EDIT MATERIAL PARAMETERS SET TEST SPEED SET BUZZER MODE SET MOISTURE RATE EDIT LIGUID PARAMETERS SET LIQUID ONLY PRINT CURRENT SETTINGS l MAIH BACK MEHU Rotate the scroll switch until the Lock Spread Rate icon is highlighted To enter the Lock Spread Rate Screen Press the scroll switch ROMARQUIP LOCK SPREAD RATE ep STATUS UNLOCKED i MAIH BACK MEHU Press F1 to Lock Unlock the Spread Rate Press F5 to go back to the Spreader Settings screen ROMR UIP SPREADER SETTINGS EDIT MATERIAL PARAMETERS i IM AIH BACK MEHL Rotate the scroll switch until the Lock Spread Width icon is highlighted To enter the Lock Spread Width
25. e scroll switch until the Set Liquid Only icon is highlighted To enter the Set Liquid Only Screen Press the scroll switch RomaQuip Ltd Birr Co Offaly Set Liquid Only Current Setting BACK MAM The current setting is displayed at the top of the screen To set liquid only on use the scroll button to select ON to accept new setting press the scroll button The new setting will be displayed on the top of the screen Press F5 to return to the main spreader settings screen ROMPF LIP SPREADER SETTINGS EDIT MATERIAL PARAMETERS Rotate the scroll switch until the Print Current Settings icon is highlighted The following screen will appear ROMR UIP SPREADER SETTINGS Saving Spreader Settings al to Memory Card BACK MAH A mote appears on the bottom left of the screen Saving Spreader settings to memory card This will be displayed for 5 Seconds while all the settings are been saved to the PCMCIA Card When complete press F5 to return to the main setup screen Spreader Settings now completed press F6 to return to the main menu RomaQuip Ltd Birr Co Offaly 10 ROMKQUIP is User Manual Fleet Supervisor SETUP Alarms Edit Drivers Edit Routes amp Clock SETUP Note When using the scroll button to scroll to a desired setting a red box will indicate which setting 1s currently been highlighted ROMP LIP MAIN MENU 3 gm I gt MOUHT BRINE TANK LIGH
26. ip Ltd Birr Co Offaly LOGOUT ROMR UIP MAIN MENU MOUNT BRINE TANK DEMOUHT UNLOAD f FILLING DISPLAY LOGOUT To Logout of the system scroll to logout Press the scroll button to accept The following screen will appear ROMK amp ULIP MAIN MENU LL Logging Name tank FILLING Please Wait LOGOUT The above message will pop up for a couple of seconds The login screen will then appear ROMRQUIP LOGIN TYPE DRIVER TECHNICIAN FACTORY Va Beta To log back in select the relevant log n type and input appropriate user name and password RomaQuip Ltd Birr Co Offaly
27. l button For example 10g m2 needs to be inputted After pressing the scroll button the spreading page 1s shown again ROMA UIP 201 1 12009 15 51 SPREADING OFF DATA LOGGING OFF I I L ils TID PLOUGH MAIN SYMM Font ON OFF MEHU The rate has now changed to 10g m2 To change the Symmetry press F3 The following screen will apply RomaQuip Ltd Birr Co Offaly 10 PATTERN Centre On the left the current spread rate s displayed To change the symmetry Use the scroll button to scroll left or r ght depending on the spread required The pattern will be displayed on the top and bottom of the screen as you toggle through them Press the scroll button when the desired spread pattern is shown e g select the centre pattern The screen now goes back to the spreading screen 201 1 12009 16 06 SPREADING OFF DATA LOGGING OFF I I L The symmetry selected can now be seen on the illustration To put the plough into the float position press F4 The following screen will appear 207 1 2009 16 10 SPREADING OFF DATA LOGGING OFF pid T SPREAD PLOUGH MAIN SYMM RAISE OH OFF MEHU The illustration w ll show the plough been lowered to the floating position This screen will disappear after a few seconds and the spreading screen will appear To raise the plough press F4 The following screen will appear RomaQuip Ltd Birr Co Offaly 11 201 1 12008 16 12 SPREADING OFF DATA LOGGING
28. nner To use the spin unload the spinner has to be in the ready position i e amp is shown in the spinner assembly folded forward box as shown below ROMRQUIP UNLOAD GRITTER PLEASE ENSURE THE FOLLOWING W Spreading has been Turned Off W The Vehicle is stopped Bl The Spinner Assembly is Folded Forward untold spinner to use spin unload Press to empty the spreader v MAIN EMPTY MEHU Spreading has been turned off and the vehicle is stopped as indicated with Spinner assembly is in the ready position as indicated with Bl Press Fl to do a spin unload The following screen will appear RomaQuip Ltd Birr Co Offaly ROMK amp LIP UNLOAD GRITTER PLEASE ENSURE THE FOLLOWING af Spreading has been Turned Off af The Vehicle is stopped H The Spinner Assembly is Folded Forward untold spinner to use spin unload Press to empty the spreader i EMPTY EHI Press F1 to stop the spin unload Unloading of the salt complete press F6 to return to the main screen RomaQuip Ltd Birr Co Offaly ROMKQUIP is User Manual Brine Tank Filling Brine Tank Filling Note When using the scroll button to scroll to a desired setting a red box will indicate which setting 1s currently been highlighted ROMKG amp UIP MAIN MENU pn nie p BRIHE TANK SPREAD LIGHTS ar UHLOAD FIL LIHG T N LOGOUT Using the scroll button scroll to Brine Tank Filling Press the scroll button to selec
29. running above 10km an hour spot cannot be used Blast 1s used instead Press Fl when running above 10km and the following screen appears TH Hard Shoulder Off BLAST Six OA x ONOFF OUGH OHIOFF RomaQuip Ltd Birr Co Offaly 8 The FA will flash red white while the salt is been blasted out of the spinner assembly Press F1 to stop the blast The main spreading screen will appear ROMRKQUIP ADT DTH Hard Shoulder Off t Ogm RATE DEFAULT Lane 2 T O HIN O p MAIN BLAST ON OFF Deflector OUS owiorr MEHU To see a more detailed spreading screen press amp hold down the scroll button until the screen changes to the one below en 201 1 12009 15 07 SPREADING OFF DATA LOGGING OFF l I L PLOUGH Transport TO TID MAIH OUS oniorr MENU This screen provides more information for the spread settings Press F1 to enter the set the width screen The following screen appears Use the scroll button to select the spread width 0 13m Press the scroll button to accept new width spread e g 8m The spreading screen appears RomaQuip Ltd Birr Co Offaly 9 ROMR UIP 201 1 2009 15 43 SPREADING OFF DATA LOGGING _ FF mM Li PLOUGH MAIH FLOAT OH OFF MEHU The 8m inputted on the previous screen is shown here To change the Rate g m2 press F2 The following screen appears Using the scroll button scroll to the desired rate and press the scrol
30. s the scroll button to accept The following screen will appear RomaQuip Ltd Birr Co Offaly 3 ROMK amp LIP EDIT ROUTES A MAIH BACK MEHU Here the list of pre defined routes ROOI to R012 will be displayed to scroll between then use the scroll button to accept the new ROUTE press the scroll button Press F5 to return to the main setup screen ROMRSLIP SETUP Using the scroll button select Clock and press the scroll button to accept The following screen will appear a SET TIMEIDATE TIME 14 16 44 DATE 19 1 72005 4 BACK MEHL MAIN The current date and time will be displayed Press Fl or F2 to adjust hours for daylight savings time The clock needs to be set properly so as all alarms etc can be recorded correctly Press F5 to return to the main setup screen Setup now complete press F6 to return to the main menu RomaQuip Ltd Birr Co Offaly ROMKQUIP is User Manual Spread SPREAD Note When using the scroll button to scroll to a desired setting a red box will indicate which setting s currently been highlighted ROMRQUIP MAIN MENU MOUNT BRIHE TANK DEMOUHT UPLOAD f FILLING LOGOUT Using the scroll button scroll to SPREAD Press the scroll button to select The screen below will appear ROMPQUIP DTH Hard Shoulder Off 0 gin RATE DEFAULT Lane 2 E Ost Ds ed PLOUGH MAIN Lud BLAST ON OFF Deflector OH OFF
31. t The screen below will appear BRINE TANK FILLING Brine Plug Attached This screen will appear if the brine plug has not been attached The brine level shown above is 0 This states that there is no brine currently n the tank If the brine plug is attached the following screen will appear RomaQuip Ltd Birr Co Offaly UIP BRINE TANK FILLING Brine Plug Attached Brine Level Yes 1s displayed in the box to show the brine plug 1s attached Brine filling can now commence When the tank reaches 10046 the following screen will appear ROMNGDIP BRINE TANK FILLING Brine Plug Attached ALARM Brine Tanks Full Remove Brine Filling Flug When the tank reaches 100 an alarm appears saying the tank 1s full and the brine plug is too be removed Brine Tank Filling complete press F6 to return to the main screen RomaQuip Ltd Birr Co Offaly ROMKQUIP ts User Manual Material Calibration Material Calibration Note When using the scroll button to scroll to a desired setting a red box will indicate which setting is currently been highlighted ROMKQUIP MAIN MENU MOUNT BRIHE TANK DEMOUHT UPLOAD f FILLING LOGOUT Using the scroll button scroll to MATERIAL CALIB The screen below will appear ROMK amp LIP Material Calibration Spread Rate Salt Only 47 3 ka min 7 7 kaimin 1 Lane HS Belt Charge Time 305 5 SAIT RESET CALIB MAIN START cHARGE
32. ted To enter the Set spread width range Screen Press the scroll switch ROMARGUIP Spread Width Range Current 3 meters Current value is shown at the top of the screen Minimum 3m Maximum 13m To change this use the scroll button to select new value and press the scroll button to accept new value ROMARGUIP SPREADER SETTINGS Press F5 to return to the main spreader settings screen Rotate the scroll switch until the Set emer Gate height icon is highlighted To enter the Set emer Gate height Screen Press the scroll switch ROMAGUIP Emergency gate height Current ee BACK MAIR The current value is shown at the top of the screen To change this use he scroll button to scroll to the new value and press the scroll button to accept The new value will now be displayed on the top of the screen Press F5 to return to the main spreader settings screen RomaQuip Ltd Birr Co Offaly ROMARGUIP SPREADER SETTINGS SET TEST SPEED SET BUZZER MODE SET MOISTURE RATE EDIT LIQUID PARAMETERS SET LIQUIO ONLY PRINT CURRENT SETTINGS Rotate the scroll switch until the Set Blast Rate icon is highlighted To enter the Set Blast Rate Screen Press the scroll switch ROMAGLIP Blast Rate Current 3 Value 40 g m M IRIS BACK il The current blast rate is shown at the top of the screen default 40g m2 To change this use the scroll button to select a new value press the scroll button to accept the new v

Download Pdf Manuals

image

Related Search

Related Contents

Notice - Castorama  Crate Amplifiers E60065 Musical Instrument Amplifier User Manual  PregnanStick™ - Savyon Diagnostics  Phonix S9300HAG mobile phone case  cliquer ici - Lycée Saint François d`Assise, La Roche sur Yon  USER`S MANUAL - Pdfstream.manualsonline.com    システムキッチン取扱説明書 SH(タイプX)  CLR 40 - BLAUPUNKT  Technics EUR643809 User's Manual  