Home
        Portable Surge Protective Device Tester SPD T8 tester User Manual
         Contents
1.   X PAST    Portable Surge Protective Device Tester    SPD T8 tester  User Manual       JD Auspice Co  Ltd  TEL  886 2 2595 9780 FAX  886 2 2595 9412 service jdauspice com www jdauspice com      N ANZ    Index    oVer                        1  Index                              2  Safety Precaution                             3  Packaging                    3  Introduction                              4  Standards  applications                                        4  Speeification                                 5  Control Function                                               6  Operation Procedure                                           7  Operation Procedure                                           8  Procedure for Batteries Replacement                      9  Maintenance and Repair                                      10  Troubleshooting                                                 11  Measurement Inspection Method                           12  Measurement Inspection Method                           13  Technical Enquiry                                              13   SPD T8 tester _2        JD Auspice Co  Ltd  TEL  886 2 2595 9780 FAX  886 2 2595 9412 service jdauspice com www jdauspice com    HAPHE   Safety Precaution A    This tester can produce up to 1000V testing voltage  To obtain accurate performance and    prevent injury   please follow the safety instructions below    1   Before the    TEST    button is pressed  make sure the tester connection with test
2.  If  it is Voltage Switching Type  e g  Gas Discharge Tube   the reading is Break Through  Voltage     SPD T8 tester Ts       JD Auspice Co  Ltd  TEL  886 2 2595 9780 FAX  886 2 2595 9412 service jdauspice com www jdauspic    pa  URUN   amp  oe SPD TESTING INSTRUMENT    2 2 For the measurement of known SPD Nominal Voltage     Switch     OM     to     Un     position      According to component Nominal Voltage  if it is less than 600V  then press the      VS     to    600V    position  if it is larger than 600V then press the     VS     to     1000V    position      Connect the tester to the testing component by the tester rods    Press the    TEST    button  until the buzzer produces    Beep    sound  LCD shows  the stable value with the unit    V     then release the    TEST    button   Compare the reading with the specification of the component       Attention   For Nominal Voltage measurement  the reading is valid only after the       TEST    button is pressed for more than 2 second with the    BEEP    sound as  indication from the tester buzzer  Otherwise  the reading is invalid    2 3 Leakage Current Measurement     Connect the testing component to the tester by the two testing rods      Turn     OM     to     VA     Position      According to the preset testing voltage  turn the adjust     VS     to a suitable  position   If the testing voltage is smaller than 600V  turn     VS     to    600V     position  For more than 600V  turn     VS     to    1000V    position     
3.  Press the    TEST    button  adjust the     VA     button  Clockwise  Increase      Aclockwise  decrease  until the display value equal to the preset value  then release  the button      Switch     OM     to    ILeak    position and press the     TEST    button  The LCD display the leakage LI   current  uA   of the testing component    Attention      The maximum reading for leakage current is 199 9u A  For reading   larger than 199 91 A will only display a    1    on tester LCD      2     There are no beep sound indication on operation mode     OM     on      VA     and    ILeak    position     SPD T8 tester Rs       JD Auspice Co  Ltd  TEL  886 2 2595 9780 FAX  886 2 2595 9412 service jdauspice com www jdauspic    PAF STE   amp  HL SPD TESTING INSTRUMENT    Procedure for Battery Placement       shown the       LOBAT         it is necessary to replace the batteries      Here is the procedure        1  Remove the tester rods    2  Screw up the screws at the back of the tester   3  Open the battery cover    4  Remove the old batteries     5  Install the new batteries  screw the battery cover back to the tester           Screwing Position    SPD T8 tester  9        JD Auspice Co  Ltd  TEL  886 2 2595 9780 FAX  886 2 2595 9412 service jdauspice com www jdauspic      a   H ANZ  Qema e       Maintenance and Repair  To make sure each measurement is accurate  keep the tester away from   shock    corrosive gases  salt and high temperature  etc     After testing  remove the tester rod
4. Life 500 measurements                 11  Technical Specification                                   Measurement Range Range Resolution   Accuracy  1mA DC 600V 50V 600V 1V 3   5  Reference   1000V 500V 1000V 1V 3   5  Voltage  600V 50V 700V 1V 3   5  Discharge Voltage  1000V 500V 1200V 1V 3  5  Leakage Current 0 199 9uA 2 0 199 9uA 0 1 pA 5    10        Internal Buzzer beeps for each successful measurement      iii  Safety Parameter                   Maximum Overload Current 2mA  Maximum Output Voltage  lt  1500V   No Load    Case Protection Level IP65  Calibration cycle Once a year   recommendation              SPD T8 tester    JD Auspice Co  Ltd        TEL  886 2 2595 9780 FAX  886 2 2595 9412 service jdauspice com www jdauspic       a 3 4 F   amp  DB  SPD TESTING INSTRUMENT    Control Function    1  Output Terminal   RED   Positive  Black   Negative    2  LCD Display    3  Test Voltage Range Selector     VS      Range    i  600V   ii  1000V  4  Voltage Adjustment Switch     VA              5  Operation Mode Selector     OM      Mode    i  UN   Nominal Voltage Measurement   ii  VA   Test Voltage Adjustment     iii Ieak   Leakage Current Measurement    6     TEST    button     SPD T8 tester  6        JD Auspice Co  Ltd  TEL  886 2 2595 9780 FAX  886 2 2595 9412 service jdauspice com www jdauspic    J S vA    amp  ee SPD TESTING INSTRUMENT    Operation Procedure    1  Connection  1 1 Connect the red and black tester rods to the output terminal  Then  short circuit the  tester 
5. T    button  read the reading on the LCD until    BEEP    sound  from the buzzer  Obtain the current value  Reading Voltage Standard Resistance   if it is equal to the constant current value 1mA  from the tester  error should be    smaller than   5      3  Check for the measurement error of the Leakage Current   1  Connect with standard resistor 1OMQ   0 5  to the output terminal    2  Turn     OM     to     VA     position  Press the    TEST    button  Adjust the     VA      knob to a suitable voltage display    3  Keep pressing the    TEST    button and turn     OM     to    ILeak    position  simultaneously    4  Obtain the leakage current value  Voltage on voltmeter Standard Resistance     5  The different between the LCD reading and the value obtained on previous step  should be smaller than   3    10 digit   4  Check for Conducting Voltage Measurement Accuracy   1  Turn the Operation Mode Selector      OM     to     UN     position     SPD T8 tester  12        JD Auspice Co  Ltd  TEL  886 2 2595 9780 FAX  886 2 2595 9412 service jdauspice com www jdauspic    BAR NPAT   amp  ne SPD TESTING INSTRUMENT     2  Set the Test Voltage Range Selector      VS     to    600V        3    Screw up the screws at the back of the tester  Oper the battery cover     4  Connect the output terminal with a gas tube  Simultaneously  connect the red  terminal with the signal lead of oscilloscope probe  connect the negative pole of  the battery with the reference lead of oscilloscope probe  Pr
6. ess the    TEST     button  read the reading on the LCD until    BEEP    sound from the buzzer   Obtain the breakdown voltage to check if the different in reading and the  oscilloscope measurement is inside an acceptable range of error percentage     5  Set the Test Voltage Range Selector      VS     to    1000V    and repeat the above    steps     SPD T8 tester  13        JD Auspice Co  Ltd  TEL  886 2 2595 9780 FAX  886 2 2595 9412 service jdauspice com www jdauspic    
7. ing    component is complete     2   During the    TEST    button is pressing  do not touch the testing component and the    cable of the tester     3   After the    TEST    button is released  wait for about 5 second before touching any    component     4   Short circuit the testing rods before and after each test    5   DO not press the    TEST    button when no testing component connected    6   Make sure the batteries in the tester are in correct polarity   7   Remove the batteries for long time storage    8   When LCD Display shows    LOBAT     it mean low battery supply  battery    replacement is necessary  Otherwise  accuracy of measurement will be affected and the    internal circuit of the tester may not fully operate   Packaging    The SPD Tester Box set includes the following items           Table 1 SPD Tester T8 Item List                                  ITEM   Quantity  1 SPD Tester T8 1  2 Tester Bag 1  3 Testing rods 2    4 1 5 V LR6 Alkaline Batteries 4 l   5 User manual 1  SPD T8 tester  3         JD Auspice Co  Ltd  TEL  886 2 2595 9780 FAX  886 2 2595 9412 service jdauspice com www jdauspic          JA NT   amp  nn SPD TESTING INSTRUMENT    Introduction    Surge Protective Devices Tester  SPD Tester T8 is designed for on site  testing of Surge Protective Devices  SPD   It allow to measures both the  Nominal Voltage and Leakage Current of different SPDs  Users can  determine the status of these components according to the tester readings        The tester ca
8. n measure both type of main component inside SPDs  including     a Voltage Limiting Type  MOV  TVS  Zener Diode     The SPD tester injects a constant current into the component and measure the Let   Through Voltage  Then  the tester can use this voltage to find out the leakage current of  the component     b Voltage Switching Type  Gas Discharge Tube  Solid Discharge Tube  Spark Gap    The SPD tester injects a constant current into the component and measure the Break  Down Voltage of the component  What the tester outputs is slope of 10V ms voltage not a  constant current    Standards  applications   This Tester is made with reference to IEC 61643 part 1 and part 21   IEC 61643    Surge protective devices connected to low voltage power distribution  system      Part 1  Performance requirements and testing methods  Class I and II tests   IEC 61643    Surge protective devices connected to telecommunications and signaling    networks     Part 21  Performance requirements and testing methods    SPD T8 tester  4        JD Auspice Co  Ltd  TEL  886 2 2595 9780 FAX  886 2 2595 9412 service jdauspice com www jdauspic    PAL     amp  nn SPD TESTING INSTRUMENT                               Specification  Dimension   Length x Width x Deep  nur  Weight 0 8kg  Case Material ABS  Display LCD 15mm Height Digit  Light Grey Case Red and Black tester  Color  rod  Operation Temp  0C  40C  Operation Humidity  lt  75   Storage Temp   10  C  50C  Power Supply 4x 1 5V LR6 Alkaline Battery  Battery 
9. ng Type  Component  Max  Break    through voltage is 1200V       After     OM     Turn to     VA      Position and press    TEST     button  Output voltage remains  constant no matter adjusting    the     VA         The testing component is  conducted but the output    voltage is limited     Check the Nominal Voltage of    the testing component          During the leakage current test     the LCD displays    1          The leakage current of the    testing component is larger than    199 9u A       Turn     OM     to     VA     and set  the voltage for leakage current    measurement again       JD Auspice Co  Ltd     SPD T8 tester    TEL  886 2 2595 9780 FAX  886 2 2595 9412     11        service  jdauspice com wwvw idauspic       Paf  IN    amp  u oy SPD TESTING INSTRUMENT    Measurement Inspection Method    The following method suitable for the tester after periodic check or maintenance    1  Check for Output Voltage Accuracy   1  Turn     OM     to     VA     position  connect the output terminal to a standard  voltmeter    Red Terminal  positive pole  Black Terminal  Negative Pole    2  Press the    TEST    button and adjust the     VA     button  compare the LCD  reading with the reading on the voltmeter  Check if the different in reading is    inside an acceptable range of error percentage     2  Check for the error of Constant Current   1  Turn     OM     to     Un     position  connect the output terminal with a standard  resistor  error   0 5      2  Press the    TES
10. rods to release the charge inside the tester   1 2 Open the battery cover and insert four 1 5V LR 6 Alkaline Batteries into the tester   Make sure the batteries are in correct polarity   2  Conducting Voltage Measurement  2 1 For the conducting voltage measurement of an unknown SPD  including Voltage  Switching Type and Voltage Limiting Type component     A Turn the Operation Mode Selector      OM     to     UN     position   A Press the Test Voltage Range Selector      VS     switch to    600V      A Connect the terminal of the component to T8 tester by the two tester rods   A Press the    TEST    button for 2 second until the LCD display a numeric reading  with Unit    V     A    Beep    sound from the tester buzzer indicates the reading is    valid        Attention    A    If the LCD reading exceeds 600V  it means that the Nominal Voltage is  larger than 600V  It is required to turn the     VS     to the    1000V    side and  repeat the test again     2  If the LCD reading is inside the range of test voltage of     VS      it means      VS     selection is correct and the reading is valid       If no    Beep    sounds after the    TEST    button is pressed  it means the current  across the MOV is less than ImA or the Gas Discharge Tube does not reach  the Break Down Voltage  So the reading is invalid  Please check     VS     if it  is set to    1000V    or the output terminal is open circuit   Note  The reading is the Nominal Voltage   for Voltage Limiting Type  e g  MOV  
11. s and bring all things back to the tester box   For long time not using the tester  please remove the batteries     Ifthe LCD display    LOBAT    after pressing the    TEST    button  it mean low  battery supply  please replace the battery     If the tester requires maintenance  please contact the supplier  they will bring the tester    back to the technical service centre for further inspection     SPD T8 tester  10        JD Auspice Co  Ltd  TEL  886 2 2595 9780 FAX  886 2 2595 9412 service jdauspice com www jdauspic    HR NELAS   amp  ee  SPD TESTING INSTRUMENT          Troubleshooting  Problem Cause Suggestion  NO LCD display after    TEST      No batteries or batteries in  Check the batteries    button is pressed    wrong polarity       No    Beep    sound from the  Buzzer after the    TEST     button is pressed     Voltage Range     VS      setting is too low      i e     600V        Turn the switch      VS      to   1000V    Position       Tester Rods Open Circuit    Check if the Tester Rod are  connected to the tester and the    testing component       Testing Component is Open    Circuit    Check the component or    replace another one       Low Batteries power    Replace the batteries       Position of the     OM     is not  on     UN        Turn     OM     to the  UN        Position       The Nominal Voltage of the  testing component exceeds the    testing range of the tester     For Voltage limiting  Component  Max  Testing  Voltage is 1000V    For Voltage Switchi
    