Home

BFW revC user

image

Contents

1. A weight has been tared the display is showing the net weight The battery symbol showing the state of charge While the battery is being re charged this symbol will show four bars The weight is stable The keys perform the following functions This key is used during setting of the user functions High Low It is also used during setting of the High and Low Limits for Mode check weighing facility and for setting the alarm function This key is used to change the weighing units while the scale is in the weighing mode Unit gt It is also used for advancing the digit while the scale is in the setting mode This key is used to deduct the weight of the container from the gross weight and thus to display the net weight only Tare V It is also used to decrease the digit while the scale is in the setting mode This key is used to reset the zero position for accurate weighing while the scale is in the weighing mode Zero M It is also used to the increment digit during the setting mode 2 2 POWER SUPPLY e Power can be supplied using an internal re chargeable battery provided within the indicator case or from mains power If the battery is low on charge the symbol on the LCD will show just one bar I meaning the battery needs to be re charged immediately While the battery is being re charged this symbol will show four bars With the internal re chargeable acid battery the
2. battery life is approximately 60 hours The battery life will vary depending on the use of the backlight Adam Eguipment Company 2011 4 2 3 SETTING UP THE SCALE Indicator SS Cable with Connector Holder Cable Pillar p Unpack the scale by removing from the box Thread the cable through the pillar and place the pillar in the upright position into the rear socket of the platform base and fasten the screw Pull the cable through the holder fix the holder to the pillar and slide the indicator into the bracket Attach the cable to the interface on the indicator to complete the connection Adjust the holder to the correct position and fasten the fixed screw handle to lock it in place Adam Equipment Company 2011 3 0 OPERATIONS 3 1 POWER e Attach the mains adaptor to the power supply and plug the connector into the socket on the Indicator The indicator will charge the internal battery whenever it is connected to the 220 VAC power supply Push the ON OFF switch at the back right hand side of the indicator to the ON position to power up e Push the ON OFF switch at the back right hand side of the indicator to the OFF position to power down 3 2 ZERO FUNCTION e For accurate weighing make sure the top pan is empty and press the Zero key e The zero indicator 0 will be on 3 3 TARE FUNCTION e When the scale has a container on it press the Tare key e The Tare indicator Net will be s
3. the best of our knowledge timely complete and accurate when issued However we are not responsible for misinterpretations which may result from the reading of this material The latest version of this publication can be found on our Website www adameg uipment com Adam Eguipment Company 2011
4. value of the flashing digit and the Zero key to increase the value of the flashing digit Press Mode again to confirm the value and the display will return to normal weighing mode Once the check weighing Limits are set and the alarm function is active a beep will sound slowly when the sample weight is below the Low Limit The beep will sound quickly if the weight is above the High Limit If the sample weight is in between the Limits the beep does not sound Adam Equipment Company 2011 7 3 7 ALARM 3 7 1 Over load alarming e When a weight on the scale is over the maximum capacity the beep will sound and the display will show Err e Remove the weight immediately to avoid any damage to the scale 3 7 2 Low load alarming e If the top pan is not placed on the scale the beep will sound e Place the top pan on the scale before starting to weigh 3 7 3 Low battery alarming When T appears on the LCD re charge the battery During re charging the symbol will show four bars If this symbol appears re charge the battery immediately to avoid any damage to the battery 4 0 USER PARAMETERS The following parameters can be set by the user by entering the function setting mode Press the Tare key while switching on the indicator The first parameter will be displayed along with the settings done previously e The available parameters can be cycled through by pressing the Mode key Not all parameters may be enabled S
5. weighing yy for the chosen unit kg g Ib oz Complete Data Output For SDT 4 When the SDT is set to 4 it will send 6 lines of data in the following format lt SOH gt lt cr gt lt lf gt First line is blank G sp spXXX XXsp sp kg lt cr gt lt lf gt Gross weight printed T sp spXXX XXsp sp kg lt cr gt lt lf gt Tare weight printed N sp spXXX XXsp sp kg lt cr gt lt lf gt Net weight printed lt cr gt lt lf gt Blank line lt cr gt lt lf gt Blank line lt EOT gt End of Transmission Input command format The scale can be controlled from a PC with the following commands The commands must be sent in upper case letters i e T not t and press the Enter button Command Description Scale will send back Sends the net weight to the SN xxx xx yy or UN xxx xx yy interface Sends the gross weight to the SG xxx xx yy or UG xxx xx yy interface Sends the tare weight to the ST xxx xx yy or UT XXX XX yy interface Zero the scale This is the same as pressing Tare or Zero LXXX XX Sets the lower limit Same as Returns ERRH or ERRL if not in pressing the High Low weighing range HXXxX xx Sets the upper limit Same as Returns ERRH or ERRL if not in pressing the High Low weighing range co Disable check weighing C1 Enable check weighing Adam Equipment Company 2011 6 0 TECHNICAL PARAMETERS To enter this section pres
6. ADAM Adam Equipment BFW Platform Scales P N 700660193 Revision C December 2011 Software rev 2 4 Adam Equipment Company 2011 Adam Equipment Company 2011 CONTENTS 1 0 INTRODUC TION ee O E EE EE e 2 20 GE EE 3 2 1 KEYBOARD AND DISPLAY ode A K V eee tsar ka 3 2 2 POWER SUPPLY sou RON HO cies o ooo ooo 4 220 soe LING UP THE SCALE rozsahu eeben 5 3 0 OPERATIONS z o eet eet ate ae ek Chea ob 6 SNE EE 6 3 4 ZERO FUNG TION 35b ss hor ie ran 6 93 TARE E Ten RTE 6 3 4 UNIT SEE EC IGN st zi s bb SS EE EE ie 7 Sco gt ee He TEE 7 3 0 CHECK WEIGHING EE 7 dd lt PROP EE 8 3 7 1 Over load alarming EE 8 3 7 2 Low load alammmg eee eeeeecceee eee eeeeeeeee cette eee eee nene nenene hanna nn 8 3 7 3 LOW battery Alarm E 8 4 0 2 ee Eege EE NEE 8 4 1 BLT BACKLIGHT CONT ROL E 9 4 2 CHK CHECKWEIGHING EHNEN o de ee ee 9 4 3 RICE FILTERING GONT ROD sile a 9 delt SDT RS 232 CON TROL esst uhorskou hor ka hh k n 10 4 5 PATSSETTINE OF PARITY E 10 4 6 BPS SELECTING BAUD RA Bix aa eee as aes vee ee a ee 10 D0 AS 232 INIERFAGE sos Z Z Pana co kS 11 6 0 TECHNICAL PARAMETERS sro sk Vena cevece vee eee aka 12 Bb ZERO TRACKING WEE 12 62 UNITSETTING EE 12 Dese ZE cena cee e ater eee ee cee 13 L0 TROUBLE SHOOTING GUIDE 345333 egene 14 8 0 SERVIGEINFO FA GEO Nea he ob aa ee tee vp 15 Adam Eguipment Company 2011 1 1 0 INTRODUCTION The BFW Platform Scales are genera
7. enbigh East Milton Keynes MK1 1SW United Kingdom FCC COMPLIANCE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment The equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with this equipment to insure compliance with the pertinent RF emission limits governing this device Changes or modifications not expressly approved by Adam Equipment could void the user s authority to operate the equipment WEEE COMPLIANCE Sealed Lead Acid Battery Must be recycled Properly Any Electrical or Electronic Equipment EEE component or assembly of parts intended to be incorporated into EEE devices as defined by European Directive 2002 95 EEC must be recycled or disposed using techniques that do not introduce hazardous substances harmful to our health or the environment as listed in Directive 2002 95 EC or amending legislation Battery disposal in Landf
8. g the faulty units or parts to the service centre should be borne by the purchaser The warranty will cease to operate if the equipment is not returned in the original packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment where defects or poor performance is due to misuse accidental damage exposure to radioactive or corrosive materials negligence faulty installation unauthorised modifications or attempted repair or failure to observe the requirements and recommendations as given in this User Manual Additionally rechargeable batteries where supplied are not covered under warranty Repairs carried out under the warranty does not extend the warranty period Components removed during the warranty repairs become the company property The statutory right of the purchaser is not affected by this warranty The terms of this warranty is governed by the UK law For complete details on Warranty Information see the terms and conditions of sale available on our web site Adam Equipment Company 2011 CE Manufacturer s Declaration of Conformity This product has been manufactured in accordance with the harmonised European standards following the provisions of the below stated directives Electro Magnetic Compatibility Directive 2004 108 EC Low Voltage Directive 2006 95 EC Adam Equipment Co Ltd Bond Avenue D
9. he Unit key to change to change the setting 1 Continuous output 2 Outputs under command from PC 3 Outputs weight when the scale is stable 4 Outputs complete data to printer when scale is stable e Press the Mode key to store the setting and move on 4 5 PAT SETTING OF PARITY e When PAT is displayed press the Unit key to change to change the setting 8 n1 8 data bits no parity default setting 7 E1 7 data bits even parity 7 01 7 data bits odd parity e Press the Mode key to store the setting and move on 4 6 BPS SELECTING BAUD RATE e When PAT is displayed press the Unit key to change to change the setting e The options are 1200 2400 4800 and 9600 default e Press the Mode key to store the setting and move on e To return to weighing switch the scale off and then on again Adam Equipment Company 2011 5 0 RS 232 INTERFACE The BFW series of scales use a bi directional RS 232 interface Default settings are 9600 baud No Parity 8 data bits 1 stop bit 9600 N 8 1 The standard Interface parameters are onnection details are RS 232 output of weighing data Connector 9 pin d subminiature socket ASCII code Pin 2 Output Selectable Baud Pin 3 Input Selectable data bits Pin 5 Signal Ground Selectable Parity Normal Output For SDT 1 2 and 3 SN xxx xxLL yy S stands for stable U for unstable N for net weight G for gross weight LL for OK HI or LO during check
10. hown e The display will show zero If it does not show zero press the Zero key e To clear the tare remove the container and press the Tare key again If the display does not show Zero press the Zero key which will switch the Tare Net indicator off and return the scale to Zero Adam Equipment Company 2011 3 4 UNIT SELECTION e The indicator can be set for different units by pressing the Unit key The options are kilogram gram pound and ounce They can be enabled as needed see section 6 2 Kilogram is always on 3 5 WEIGHING e Place the sample on the scale platform The weight will be displayed in the selected Unit e Wait until the stable indicator is displayed for accurate weighing 3 6 CHECK WEIGHING Check weighing is a procedure to sound an alarm when the weight of the sample on the scale meets or exceeds the pre set Low and High values stored in the memory e Press the Mode key The display will show 000 00 HI with the first digit flashing for setting the High value To set your limit use the Unit key to advance the flashing digit the Tare key to decrease the value of the flashing digit and the Zero key to increase the value of the flashing digit Press Mode again to confirm the value The display will now show 000 00 LOW with the first digit flashing for setting the Low value To set your limit use the Unit key to advance the flashing digit the Tare key to decrease the
11. ill Sites is more regulated since July 2002 by regulation 9 of the Landfill England and Wales Regulations 2002 and Hazardous Waste Regulations 2005 Battery recycling has become topical and the Waste Electrical and Electronic Equipment WEEE Regulations are set to impose targets for recycling Adam Equipment Company 2011 ADAM EQUIPMENT is an ISO 9001 2008 certified global company with more than 35 years experience in the production and sale of electronic weighing equipment Adam products are predominantly designed for the Laboratory Educational Medical retail and Industrial Segments The product range can be described as follows Analytical and Precision Balances Compact and Portable Balances High Capacity Balances Moisture analysers balances Mechanical Scales Counting Scales Digital Weighing Check weighing Scales High performance Platform Scales Crane scales Medical Scales Retail Scales for Price computing For a complete listing of all Adam products visit our website at www adamequipment com Copyright by Adam Equipment Co Ltd All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment Adam Equipment reserves the right to make changes to the technology features specifications and design of the equipment without notice All information contained within this publication is to
12. l purpose weighing scales The scales have a large platform and are designed for industrial applications The main features are Available in a range of capacities Single load cell construction Overload protection Adjustable levelling feet Mild steel construction offering rugged structure Large stainless steel pan Supplied complete with AE 301 indicator Simple operation Zero Tracking Selectable automatic backlight Check weighing with low and high limits Bi directional RS 232 interface as standard Selectable communication mode Operation from internal rechargeable battery or mains power 4 weighing units kg g ounce amp pound Adam Equipment Company 2011 2 0 SPECIFICATIONS BFW 75 eee BFW 300 Maximum Capacity 75 kg 150 kg 300 kg Repeatability 5g 10g 20g Std Dev Tare Range Full range Units of Measure 4 kg g Ib oz Operating 0T to 40 Temperature Power supply Re chargeable battery located inside the indicator or mains power Display Large LCD with backlight Calibration Automatic calibration Scale Housing Indicator ABS Plastic Platform Mild steel base and stainless steel pan Pan Size w xd 470mm x 560 mm Dimensions Base 470 x 685 x 950 mm w x d xh Indicator 260 x 155 x 105 mm Net Weight 20 kg 2 1 KEYBOARD AND DISPLAY O Net 1 6 6 6 6 6 ERE ADAM Adam Eguipment Company 2011 The display has the following symbols The scale is at zero
13. nd then returns to normal weighing Remove the weight and continue to use Adam Equipment Company 2011 7 0 TROUBLE SHOOTING GUIDE PROBLEMS POSSIBLE CAUSES Display is blank On Off switch is off Battery not charged No countdown of display on power Battery not charged up Power supply not plugged in or incorrect type Power supply faulty Error message displayed Err Overload Load cell damaged Display is unstable Drafts or air currents Load cell connections not secure Obstruction under weighing platform Vibrations through the floor Temperature changed dramatically Power supply faulty Weight value incorrect Calibration error recalibrate again Unit calibrated with inaccurate weight Obstruction around platform Cannot use Full Capacity Overload stops hitting platform support or hitting bottom of load cell Parameters set incorrectly Load cell Damaged Not Linear Overload stops hitting too soon Load cell damaged Off Center Loading error Overload stops not set correctly Load cell damaged Battery will not charge Incorrect power adaptor being used Charging circuit failure Battery failure Mains voltage not present or too low Adam Equipment Company 2011 8 0 SERVICE INFORMATION This manual covers the details of operation If you have a problem with the scale that is not directly addressed by this manual then contact your supplier for assistance In order to provide fu
14. ome parameters may be set during the initial configuration and the user is not given access to them In this case those will not be seen when the Mode key is pressed To use any of the parameters see the corresponding section of the manual Switch off and switch on again to return to weighing when settings are complete Adam Equipment Company 2011 D CHK _ D RE Options are 1 2 3 and 4 Sets the following parity options 8 n 1 8 data bits no parity 1 E 1 7 databits even parity 1 01 7 data bits odd parity speed Options are 1200 2400 4800 and 9600 4 1 BLT BACKLIGHT CONTROL e The backlight can be either enabled or disabled When BLT is displayed press the Unit key to change setting BLT OFF Backlight is disabled BLT 01 Backlight is enabled e Press the Mode key to store the setting and move on 4 2 CHK CHECKWEIGHING CONTROL e When CHK is displayed press the Unit key to change setting CHK OFF Checkweighing is disabled CHK 0N Checkweighing is enabled e Press the Mode key to store the setting and move on 4 3 FIL FILTERING CONTROL e When FIL is displayed press the Unit key to change setting FIL OFF Filtering function is disabled FIL ONM Filtering function is enabled e Press the Mode key to store the setting and move on Adam Equipment Company 2011 9 4 4 SDT RS 232 CONTROL e When SDT is displayed press t
15. rther assistance the supplier will need the following information which should be kept ready A Details of your company Name of your company Contact person s name Contact telephone e mail fax or any other methods B Details of the unit purchased This part of information should always be available for any future correspondence We suggest you to fill in this form as soon as the unit is received and keep a print out in your record for ready reference Model name of the product Serial number of the unit P Software revision number Displayed when power is first turned on eee MS Name of the supplier and place p C Brief description of the problem Include any recent history of the unit For example Has it been working since it s delivered Has it been in contact with water Damaged from a fire Electrical Storms in the area Dropped on the floor etc Adam Eguipment Company 2011 WARRANTY INFORMATION Adam Equipment offers Limited Warranty Parts and Labour for the components failed due to defects in materials or workmanship Warranty starts from the date of delivery During the warranty period should any repairs be necessary the purchaser must inform its supplier or Adam Equipment Company The company or its authorised Technician reserves the right to repair or replace the components at any of its workshops depending on the severity of the problems However any freight involved in sendin
16. s and hold the Mode and the Tare key while you turn on the scale The display will show the revision number and then the first parameter Zero Tracking as ZEO 6 1 ZERO TRACKING e When ZEO is displayed press Unit to change to the other setting 1EO OFF Zero tracking function is disabled 1E0 01 Zero tracking function is enabled e Press the Mode key to store the desired setting and move to the next function 6 2 UNIT SETTING The user will be able to enable the weighing units to be used grams pounds or ounce Kilogram is the default weighing unit e When g is displayed press the Unit key to change to the other setting g OFF Gram unit is disabled g 01 Gram unit is enabled e Press the Mode key to store the desired setting and move to the next unit setting Adam Equipment Company 2011 6 3 CALIBRATION The next section is the Calibration section A weight value and WEP will be displayed e When WEI is displayed press the Unit key to scroll through the options for selecting the calibration mass To select the desired mass press the Mode key The raw ADC count will be displayed along with GAP To set the zero calibration press the Mode key again The scale will display 0 LOD place the calibration mass selected onto the top pan the display will show the raw ADC counts of the selected calibration mass then press Mode again The display shows PASS a

Download Pdf Manuals