1. z36 S z35 S z34 S z335 BELL S AUX S DC12V 500MA orhigher when without GSM module DC 12V 2Aor higher whenthe panel withGSM module Here only introduce the zone 33 34 39 40 The other zone connect the same way gt Usermanual al Installation and wiring 2 4 Install wired detector 2 4 1 The wired zone is on bypass status as factory default If the user need use wired zones please active them first When the wired zone is fault if user arm system the user will hear Opration fauilure zone trouble The LCD screen will display the fault Zone number 0 zone open loop zone 0 zone close loop zone 5 under this status pls do notarm system 2 4 2The control panel can power 12v 100mA to detectors The max current can power to wired detectors is 100mA Do not exceed 100mA otherwise please adopt extra 12V backup power 2 5 Intall wireless detector 2 5 1 As the detector s manual says install coded detector in the area 150m from the control panel Please test and make sure detector can work with control panel normally 2 5 2 Wireless repeater function when wireless detector is too far from the panel or some occluders between panel and detector which disable the panel receive the signal from wireless detector Now you can choose our made wireless repeater to achieve wireles
2. 20 5 2 Setting on main menu 20 5 3 Set password _________________ 21 5 4 Set centre monitoring station 9 5 5 Set voice alarm receiving phone number 24 5 6 System setting options _________ 95 5 7 Enroll wireless device 3 5 8 Set zone attribution _ ______ _ _ 33 5 9 Set timing operation _ ________ 3 5 10System main tenance ___________ 37 Chapter vl alarm and receive alarm 38 Chapter VII technical specification 39 Chapter VIII maintenance 49 Chapter VX limitation of the products _____ 4 0 Usermanual Accessories Accessories Before installation please check if the whole set including the components as follow ST IV series alarm panel IPC Wireless detector IPC Wireless door sensor IPC Wireless remote IPC Adaptor IPC Book manual 1PC Resistor 10K 8PCS e Screws and Plastic dowels 6PCS Usermanual al Introduction Chapter Introduction 1 1 Function Introduction 1 With voice indication all around the operation 2 LCD screen indication 3 Total 32 wireless zones each zone e
3. enter 1 032 serial number of gt 9 8 7 6 gt 5 gt 2 Mesto Dress boek kes ort Press confirm key to confirm gt amp Press the anti tam 4 Enroll per spring successfull ig 6 gt fo trioger the detector 2 Manual enrolling Example enroll the door sensor with address 145228522 to zone 16 press and hold on for 3S 4 enter 1 to32 serial number of gt 9 8 7 6 gt 5 gt 4 detector Press back key to exit Press confirm key to confirm gt 6 gt enter address code of detector Press back to exit press confirm or to confirm gt 4 5 2 User can find the 9 digit gt 4 Setting is saves address code on the label sticked on the detector Usermanual system setting 3 Example delete 16 detector press and hold on for 3S enter number 1 to 32 serial number of detector to delete gt 9 8 7 6 gt 5 I gt 6 seperately enter 00 to delete all Press back key to exit Press confirm key to confirm 4 press back key to exit ay press confirm key to confirm gt X setting is saved Save the settings gt We gt 5 7 3 Enroll wireless siren code Example Enroll wireless siren code press and hold on for 3S gt 9 8 7 6 gt 5 gt 7 o
4. Perimeter zone delay zone lt iseffective under away arm orhome arm status Key zones 33 40 wired zones can be programmed as key zones When the zone is programmed as key zone the panel status will be same as current key zones status when power on instead ofrest oring to the status before power off Ifthere is more than one key zones then the panel status will be the same as the key zones with maximum number Wiring method of key zones 1 N C 2 N 0 ZONE ZONE O SW O SW Panel A Panel tot COM COM O mi O 7 A Access switch Access switch Zone zone wiring termind GND common terminal SW switch Eol resistor User can program the zone type when the zone is triggered the panel will report the preset zone type information of triggered zone to CMS Hint When the zone type is programmed as 0 that means the zone is disabled bypassed Notes Open circuit is to arm automatically Disarm when zone is in normal status User manua system setting 5 9 Set timing operation Example Set timing arm disarm timing arm at 12 34 timing disarm at 22 54 Press for 3 seconds 9 8 7 6 7 then operate according to the voice indication Timing setting y v 2 3 4 q One set 1 timing arm disarm time q Two set 2 timing 4 Three set 3 timing arm disarm time arm disarm time q enter timing armtime Itis invalid to set both ho
5. exclude high siren current 9 Main machine 12v maximum output current lt 100mA for wired detectors 10 Recording time 15s 11 Frequency 433MHz 0 5MHz 12 The trigger delay of wired zones 2100 ms 13 The method of alarming dial DTMF GSM 14 DTMF dial frequency variation lt 1 5 15 Communication Protocol with CMS Ademco Contact ID 7 2 Physical Performance Operation temperature range 32 F to 120 F 0 C to 45 C Storage temperature range 4 F to 140 F 20 C to 60 C Relative humidity 85 at 30 C 86 F Dimensions 230 160 38mm Weight 550g Color white User manua Maintenance Chapter VII Maintenance 8 1 Regular test Design of components of the system is to reduce maintenance cost but still itis suggested that periodical check may be carried out 8 2 The cleanliness of control main machine Main control panel maybe be stained by fingers or covered by dust after using for a while Use soft cotton cloth or sponge to clean it Don t use any lubricant liquor such as kerosene acetone and strong gel which will damage appearance and the transparency of top window ATTENTION Don t use any lubricant liquor such as kerosene acetone and strong gel which will damage appearance and the top transparency of window Chapter V X Limitation of the Products Although the products is a high standard products there is also some limitation of them such as false alarm or no alarm the reasons may be below Lack of Maint
6. on for 3seconds will turn off the backup battery When battery voltage reduce to 8 5v system will turn off auto matically to protect battery System setting press Jand hold on for 3 seconds administrator password key Disarm the system user password Shorcut operation numeric key 1 8 separately correspond to 8 electroniswitch Press the numeric key and hold on for 3seconds will switch on off the corresponding electronic appliance General operation press and hold on key O for 3seconds to enter electroric appliacace setting modeswitch on off electronic appliance press and hold on key 0 for 3seconds to enter electroric appliacace setting modeinquiry on off status of electronic appliance press and hold on key O for 3seconds to enter electroric appliacace setting mode set timing on off electronic appliance The panel will sound voice indication of setting options anytime entering any menu Change to neighbour option via up and down key Usermanual a Easy setup and operation 3 3 Alarm receiving phones operation When the detector is triggered the panel will sound alarm and display the triggered zone number and alarm type on the LCD screen If the zone is delay zone the pannel will give pre alarm dee dee sound before make alarm if user do not disarm during the pre alarm period the panel will wisthle and dial alarm receiving phone When the panel dial the alarm receiving phone but user does not an
7. Ase fs lt DI DI DI D c e 2007 v 2007 mm aal NNM 0 02 UU ooe LOS Plas fx Press the panic button on remoter or press press the disarm key on the remote or enter confirm panic key on panel for 3 seconds your user password on the keypad then you and 10seconds later the panel will dial the will hear dee and voice system disarmed preset phone number And you can disarm to then you have disarm successfully cancel alarm After above mentioned operation press up inquiry button for3 seconds and you can inquiry record event like emergency alarm home arm and so on Press up key to previous option Press down key to inquiry next event Press key to exit inquiry Usermanual Easy setup and operation 3 11 Electronic switch operation Press 0 key for 3s to enter corressponding menu electronic appliance control Press 0 key and hold on for 3 seconds y Electronic appliance control press 1 4 Check on off status of Set timing switch on off electronic appliance electronic aep ance press press 2 aj Ble DA Enter the serial number of s Enter the serial number d Enter the serial number electronic appliance of electronic appliance of electronic appliance otea Oe Oe The electronic appliance gn is already switch on off 4 0 me electronig h off Please enter timing please press 1 to switch BPP
8. key to confirm G Exit system setting enter walking testin g mode press back key to exit 4 A Under communicat ion testing press return key to exit 4 Setting is saved If communication is normal 4 Communication testing success full If communication failure A Communication testing failure press return key to exit 4 4 4 Back to factory Panel enter default press record mode at Play the once and the back key to time is 15seconds alarm exit press confirm i address then willplay the record speech keyto confirm saved Walk test Test ifthe panel can work with the detectors Under walk test trigger the detector the siren ofpanel will hootabout 2s after testing press arm the panel willback to normal status Communication test Test ifthe panel canwork with CMS arm and receive alarm gt Chapter Vl alarm and receive alarm 6 1 Only the zone type witch is set to be burglar alarming or perimeter alarming is controlled by the operation of away arming home arming disarming Other zone types are on the statu of the 24 hours valid If spring alarming the types of burglar alarm perimeter alarming and self defining alarming will alarm after a delay time but the other types will immediately alarm through dial up 6 2The panels adopt Contact ID for the communication protocol to send the alarming information to the center If the pa
9. Ed 8 5 3 Set password Set password Password include user pasword and administrator password user password with function to disarm system It is a private key on remote control Adminstrator password is the only password to set the system Please do not forget the administrator password otherwise you can not operate the system Press hold for more than 3 seconds 9876 1 then operate according to the speech indication Press then enter administrator password then press 1 y y Set password y 1 modify administrator password DA Please enter new four digit administrator password 4 2 user password setting a q Please enter new four digit user password Press back key to exist press confirm 4 Press lene Heyl exist keya cave ress confirm Ke o save MMMM e wim mM q Setting is saved Setting is saved 1 administrator setting 2 password setting Press back key to back to previous menu 1 administrator setting 2 password setting Press back key to back to previous menu Usermanual System setting Note Here M stands for entering new password Example 1 Modify the administrator password to 1111 Press key and hold on for 3 seconds 4 Se pa gt 9 i 8 7 6 gt gt 1 4 1 set password q Pleas
10. Enrolling please wait Press the SAVE key of the wireless siren till the panel and siren sound at the same time press back key to exit 5 7 4 Enroll and delete electronic appliance switch code Example enroll 5 electronic switch max 8 r Press and hold on for 3S q Enter serial number of No 1 to 8 switch Press back key to exit Press confirm key to confirm 4 trigger the switch press the button of 4 Enroll gt 5 gt press back key to exit gt ane erential ell successfully press confirm key to confirm LED flash L gt 9 8 7 ol4 gt 5 gt 8 4 Example delete 5 electronic switch press and hold on for 3S 4 enter number 1 to8 serial number gt 9 8 7 6 gt 5 gt 9 of electronic switch to delete separately enter 0 to delete all Press back key to exit Press confirm key to confirm gt Setting is saved Save the settings 4 press back key to exit press confirm key to confirm gt 5 gt gt B24 User manua System setting 5 8 Set zone attribution Press 3seconds 9 8 7 6 6 then operate follow the voice indication Zone attribution setting y v One set zone attribution Two set zone siren type enter one to forty zone number 4 enter one to forty zone number to modify press
11. MS Theuser code should be 4 6 or 8 digit press confirm key to save press to delete xxx v 4 Setting is saved Xx When set CMS phone please press then enter the phone When only delete phone press then press If settwo CMS phone please set two user Usermanual System setting 5 5 Set voice alarm receiving phone number After press 3 seconds 9876 3 operator follow the voice indication Set voice alarm receiving l J i DOE 1 1 set first voice 1 2 set second voice 3 set third voice 1 set fourth voice alarm receiving alarm receiving alarm receiving alarm receiving phone number phone number phone number phone number 4 Enter phone press back key to exit press confirm key to save press to delete Example 2 panel connect with one telephone And set the local phone 87654321 as first voice alarm receiving S Press for 3seconds 4 Enter password gt 9 8 7 6 J 4 3 Set voice alarm receiving gt 3 press back key to exit press confirm key to save pressf to delete gt 0 7 5 5 8 7 6 5 4 3 2 14 gt 9 Enter phone gt System back to the previous menu Usermanual System setting 5 6 System setting options Press 3seconds 9876 4
12. ST IV User Manual oaoa alaaa aaae DOAA P N 20110309 4 User manua Preface Brief gt Dear customer Congratulations on purchasing your new security systeman thank you for the confidence you have shown in us You have chosena high quality product that has been produced tested and packed w thegreatest care Please familiarize yourself with these instructions before attempting to install the security system because prolonged reliable and trouble free operation will only been sure if it is fitted properly We hope your new security system will bring you lasting pleasure User manua Content 3 11 Electronic switch operation Content Accessories Chapter Introduction 2 1 1 Function introduction 2 1 2 About panel 5 1 3 About CON 5 Chapter II installation and connection 6 2 1 Open the item Box 6 2 2 Installation of control panel 6 2 3Wiring 7 2 4 Install wired detector 8 2 5 Intall wireless detector 8 Chapter IIl easy setup and operation 9 3 1 Factory default setting 9 3 2 Basic setting and operdtion 11 3 3 Alarm receiving phone control 12 3 4 Remote phone control 12 3 5 Alarm center 13 3 6 Alarm proctdure 13 3 7 Telephone line off alarm 15 3 8 Anti taper function 15 3 9 Event recording and inqaivy 15 3 10 Easy operation 17 jee User manaa Content Chapter IV User setting __________ 19 Chapter V system setting ____ 90 5 1 Setting
13. an 10 Like 9 enter as 09 gt Usermanual system setting 5 68 Set arming disarming tone Set the tone type of arming disarming default value is no indication Example set armed idsarmed with short sound tone indication press for 3s Choose arm disarm indication voice One no voice two short sound gt 9 8 7 6 gt 4 i gt 8 Press back key to exit Press confirm key to save gt Setting is saved 1 noindication 2 short sound 5 69 Set arming disarming report Setifreport arm disarm to CMS or not Example Set arm disarm report to CMS Press and hold on for 3s 4 Please choose arm disarm report one not report two report gt 9 8 7 6 gt f 4 i gt 9 Press back key to exit Press confirm key to save gt gt Setting is saveda gt Setting is saved 1 not report 2 report Usermanual system setting 5 7 Enroll wireless device Pressing 9876 5 then operate follow the voice indication 1 Enroll remote Press and hold on for 3s 2 enroll detector 3 Enter code of remote 4 Enter code of detector 1 2 E 4 gt 9 8 7 6 gt 5H 5 5 delete remote 6 7 8 9 6 delete detector 7 Enroll wireless siren It s suggested user to enroll detectors remote by manually enter the codes ngt Enro
14. back key to exit to modify 00 for emergency button press confirm key to confirm press back key to exit press confirm key to confirm Chose zone type 0 disable the zone 1 delay zone 2 perimeter alarm zone 3 burglar alarm zone 4 4 Chose zone type siren one pedal emergency alarm zone 5 fire alarm zone point two pulse tone three mute 6 gas leak alarm 7 keyzone 8 door bell zone Press back key to exit zone press back key to exit press confirm key to confirm N A press confirm key to confirm y nN NJ uoz ej p auoz seb auoz Kay uoz Ja awiiad uoz weje ally Wnr uoz jj q 100q ssedAq u uewa d le uoz wueje sejBing U uoz wieje Aouebiewe Note 00 is only for emergency button of the panel or remote Key zones only for wired zones 33 40 used for access control when set as key zones the burglar function will be disable Doorbell zones only for wireless zones 01 32 Under home arm away arm status triggerthe doorbell zone willreport delay alarm Under disarm status trigger the doorbell zone will sound ringing tone User manua System setting Special doorbell zone Under disarm status enter 858511 the zone 32 is special doorbell zone whateverarm or disarm status it will give ding dong sound Burglar zone lt iseffective only under away armstatus
15. e enter new four digit admini pent be to save gt 1 M 1 set administrator password s gt password press back key to exit press tosave gt Press 4 digit administtator Note 1 Above are based on correct operation for each step If incorrect operation occurs please press back key to back to previous menu to reset 2 The factory default of administrator password is 9876 If you have modified the password please enter the new password System setting 5 4 Set centre monitoring station Press 3 seconds 9876 2 then operate as following Set centre monitoring station y vo y 4 vy Y 5 y 6 y q set ovis 4 Iset numer 4 3 set free q 4 set free 5 set number 6 set number hone number hone number 2M Phone number disarm phone one user code two user code P P number v y yo y qa aw Ga 0A Gow Ow Enter 4 8digit user s code Os aN onet setting 4 Bae back key to exit setting press confirm key to save press to delete 2007 08 300 y xxxix x Setting is saved dr The user code in the CMS setting which is identification code in the CMS And the user code in transfer alarm setting is user identification code between same model panel Please set user code of the panel in CMS after set the C
16. e oag a ggas Built in siren G s 5 a Speech indication numeric keyboard 1 3 About ICON OR Key operation coco 6 0 68 LCD display Tu WO Mh Boh 1 l e Speech indication A Cautions dr Indication Usermanual C Installation and wiring Chapter 2 Installation and Connection 2 1 Open the Item Box Open the package to check the no accessories missing in the list If missing accessories please contact the distributor 2 2 Installation of control panel An obvious feature of the sT IVis that it can be installed without open it User just need to connect several wires on the back of the panel 1 Remove the bracket on the back of the panel Remove the bracket Push the bracket along the arrow pointed 2 Drill a hole on the wall and fixed the bracket on the wall gt SS Bracket gt O e Mounting hole_ eo Pivot e gt Mounting hole ap A Mounting knockout Usermanual al Installation and wiring As picture shows hang the panel on the bracket 1 There should be no large metal goods around the control 7 2 Make sure the distance between the control aS panels and detectors is valid And it is better to put the control panel in a covert place 2 3 Wiring As picture a Output DC 12V cI 10K 10K 4
17. enance The system needs maintenance and test regularly test The sensitive of the detectors may decrease and the siren may not whistle Lack of power supply If no power input and the back up power is not enough the panel can not work normally Telephone Line False If the telephone line is cut the panel could not send alarm signals Limitation of Smoke Detectors if the smoke is far from the smoke detector the detector could not alarm If the intruder break in through some door or window not monitored or some one knows hot to make the system not work
18. eration 3 2 Basic setting and operation Indication LED Arm Normal onunder away arm blink under homearm Disarm Light on under disarm status light offunder disarm status 12V Light on when AC power connect light off when AC power off Alarm Blink when alarming Basic setting Before left factory in whole kit the panel had already code with all remote magnetic contact PIR detector Press key for 3seconds then enter administrator password 9876 to enter system setting For each menu press to enter and press back key to exist When enter main menu panel will sound all menu options one time then user can press corresponding number or press up down to to the option you want then press to enter setting then press or confirm key to save setting When hear setting saved means setting successfully otherwise setting failure On the key button under LCD screen there are four button with function away arm hone arm inquiry panic under normal status but when under setting status the four button separately with following function back up down confirm The key on numeric keyboard numbers for user to enter numbers and for delete for confirm Under panel stanby status press disarm button for 3s for emergency help BasicOperation Power on off When power onAC backup battery will get ready auto matically When AC power off for 20seconds and enter 1234 to disarm the system press and key and hold
19. ine connected again or disarm the system this indication voice will stop Otherwise the siren whistle for 5 minutes And at then same time the panel will send alarm signal to a neighbour panel 2009 v 1 OS te LJ 3 8 Anti tamper function 1 When the control panel receive a message that the wireless magnetic contact is oping the panel will solve this as a burglar alarm up to the status code and alarm type Just after close the door or windows and panel receive the signal of magnetic contact closed The panel will then solve the anti tamper alarm 2 The display of tamper alarm on the LCD the zone number and the status code 14 for the icon is burglar 3 9 Event recording and Inquiry 3 9 1 Event record Arm away arm home arm disarmand other information can be recorded by the control panel When the battery of Wireless detector include magnetic contact is under voltage the detector can know when it make timing self testing and send signal to the control panel then the control panel will give indication voice to tell detector under voltage and display on the LCD The panel also will send message to the CMS and call the alarm receiving phone number to remind the system manager and user to change battery Usermanual Easy setup and operation 3 9 2 Event Check Press the inquiry key less than 3sec to inquiry the event recorded Press theinquiry key continuously you can get the record one by o
20. lance I5 SWRON O switch on time already 1 the electronic on or press 0 to switch off appliance is switch on y already 1jo ae 09 00 UU Correct operation Press back key to exist press 4 confirm key to confirm 4 4 Press back key to exist press confirm key to confirm al Please enter timing switch off time ee User can program multiple timer ON OFF electric switches nm on per require Long hold the numeric LI g LILI key between 1 8 of electric switch codes to enable disable the Y electronic switch 4 Press back key to exist press confirm key to confirm By Easy setup and operation Chapter IV User setting user menu WBA els 4 1 Clock setting 1 1 clock setting 2 2 set user password 3 3 voice alarm phone setting 6 6 Set zone effective or ineffective press back key to exist setting Enter 1234 A 1 enter clock setting details please read P24 chaptor 5 61 Press 3s usercode a 0A 4 Enter Y M D H M press back key to exit press confirm key to save 2009 v 06 m0 l c0 09 gt 0 9 gt 0 6 gt OJ 1 gt 2JL0J gt 0J 9 gt L gt 4 setting is save Al According to flash of Y M D H Min on screen enter 09 06 01 20 09 by turn 4 2 User password setting u
21. lbelesironicswitch 9 delete electronic switch 5 7 1 Enroll remote and delete remote Example enroll 3 remote 1 Auto enrolling Va Press and hold on for 3S Enter serial number of No 1 to 8 remote Press back key to exit Press confirm key te eonfirm gt 3 gt trigger the remote m gt A Enroll Ly B Trigger remote successfully g 2 Enroll manually Press and hold on for 3S Example set the remote with code 243222432 as the third remote gt 9 8 Zol4 gt S 4J gt a4 Enter serial number of No 1 to 8 remote Press back key to exit Press confirm key toeonfirm gt 9 8764 gt S gt B4 gt gt De gt 2432212 User can find the 9 digit address code on the label 4 3 2 gt sticked on the remote Xe J gy User manua system setting 3 Delete remote Example delete the 3 remote press and hold on for 3S 4 enter number 1 to 8 serial number of remote to delete separately enter gt 9 8 7 6 gt 5 gt 5 0 to delete all press back key to exit press confirm key to confirm Save the settings gt 3 press key to exit press 3 gt 0 key to confirm 5 7 2 Enroll and delete detetors Example enroll 16 wireless detector 1 Auto enrolling Press and hold on for 3S
22. lectrical switch press 6 ela a s amp be H hang up press 0 k J 3 5 alarm center The panel use the Ademco Contact ID to sent alarm information to the alarm center If the panel got the conformation from the center then alarm successfully Or the panel will repeat alarm the max times re dialing the center number is 5 Alarm information will be display and resolve by the alarm center computer software Usermanual Easy setup and operation 3 6 alarm procedure CMS Number Telephone Telephone Mobile F N F 3 The panel will dial 1 4 telephones as preset and the siren will sound N N Am C _ Alarm software Alarm situation found start to send message 1 the detectors activated send alarm information to y z a alarming center 2 sending alarm information ll0alarm to CMS centers e009 05x12 LCD display 1 Digital display zone number the wired zone is 33 40 the wireless zone is 1 32 the zone number is 00 for remote controller and magnetic door contat panic alarm amp telephone line off 2 Icon is for zone type indication E Easy setup and operation 3 7 Telephone line off alarm If tel line off check function is effective when system under arm status the siren will whistle as soon as the tel line cut off Under disarm status The panel will give voice to tell telephone line cut off for 60 seconds And if the tel l
23. nable learn code automatically or 9 enter code manually on the keypad The panel compatible with all our made wireless device Total 8 wired zone connect resistor on wired zone terminal to achieve N O or N C alarm Enable enroll total 8 wireless remote 8 electronic switch 1pc of wirele ss doorbell and Unlimited for quantity of one way wireless siren Zone programmable Before products left factory will programme alarm type and delay or instant for each zone as factory default Use can modify the settings Enroll wireless device wirless detector and remote via auto enroll code or enter address code manually User enable enroll delete detector remote separately or enroll delete all simultaneously Six follow me phone voice alarm receiving phone two for CMS four for private alarm receiving Clock and eventlist built in clock can be set according to local time 10 Status inspection function Enable record and inquiry 120 alarm event messages Like the time when happens anti tamper alarm detector alarm tel line off arm disarm system setting battery low voltage etc And also can inquiry the zone number and alarm type 11 Password operation Administrator password mainly for system admini strator to program the system User password for user make common operation like arm disarm system remote control Both Administrator password and user password can be modified Userman
24. nder disarm 04 perimeter Yes status Make alarm when trigger under arm status report delay s alarm We suggest only set the delay zone on entrance or exit 05 perimeter Yes FE 7 This function fit for all 40 zones set the zone attribution as 06 emergency Yes doorbell zone 07 fire Yes special doorbell zone this function is only fit for 32 zone 08 gas No Enroll a wireless device to zone 32 then set the zone attri bution as doorbell zone then enter the command 858511 09 32 burylar Yes When trigger the 32 zone pannel and siren will only give ringing tone under both arm and disarm status E Easy setup and operation Considering the convenience of user the factory default can meet most users requirement So common user only need to proceed easy setting yxZone trouble indication zonet 0 zone opentcircuit trouble zone 5 zone shortcircuit trouble zone battery icon 8 low voltage on detector trouble zone L wireless detector loss trouble means of icon displayed on LCD Icon Meaning Icon Meaning ii Home arm ie Away arm E GSM using x Disarm Telephone line fault pan Alarm F BERE Cr ae yxealarm status code 01 Delay 06 gas leak 02 perimeter 07 tamper 03 burglar 08 disarm 04 emergency 09 away arm 05 fire alarm 10 home arm gt E Easy setup and op
25. ne chronolo gically Press any key to exit For example Burglar alarm at the fifth wired zone at 8 30 am 3rd April 2009 OX Press check key e009 gt pY 03 05 o3 gt Oe Press key enter next information display yxealarm status code 01 Delay 06 gas leak 02 perimeter 07 tamper 03 burglar 08 disarm 04 emergency 09 away arm 05 fire alarm 10 home arm 3 9 3 AC power off and restoration testing function when the AC off the power LED will be off on the panel will report AC loss to the CMS and dial preset alarm receiving phone follow me if AC power does not restorlal in 30 min when the AC is restoral the panel will send restoral message to CMS after 3 min E Easy setup and operation 3 10 Easy operation yAway Arm yHome Arm ake 08 00 3 10 Oe 2007 v 10 02 gt 2007 08 00 if Press the key for arm away on remote or the keypad then you hear the system is arming Press the key for home arm on the remote or there will be 10 sounds Dee to tell you arm HOME key on the keypad the panel will give the system successfully voice to tell system is enter home arming And it display home arm icon on the LCD screen yx Panic xx Disarm
26. nel receive the acknowledgement from center then a successful alarm if not the panel will alarm repeatly alarming information can be displayed and resolved by the software of center computer 6 3 If trigger the detector alarming the corresponding panel will sound warning tone at the same time the number of springing zone and alarming type can display on the LCD If there is no disarming operation during this time after the warning time the panel will dial the receiving alarm phone number You can hear the voice information of the alarming place while listening the phone If after 10S there is no alarming disposal operation or other self defining key then the alarm process will go on When the receiving call is connected and the user operate on the panel if not press key 2 to release alarming then the panel will go on to dial up alarm with the other set number Usermanual C Technical specification Chapter VII Technical specification 7 1 General data 1 area data 8 wired areas 32 wireless zones 8 remote controllers 2 Zone type delay perimeter burglar emergency fire gas key door bell zoon events 3 Frequency 433MHz 868MHz optional 4 Signal transmit distance 100 to 150 meters open area 5 Power supply 12V 5 00mA Without GSM 12V 2 A with GSM 6 Builtin rechargenble battery 9 6 V 1600mA 7 Main machine static current 50 mA 15v exclude wire detector current 8 Main machine alarming current lt 300 mA 15v
27. operator according voice indication as following 4 clock setting 2 entry delay setting Press 3s 3 exit delay setting gt 9 8 7 6 4 gt 4 4 siren time setting 5 ringing times setting 6 detector loss test setting 7 communication test interval time setting 8 armed disarmed indication sound setting 9 armed disarm report setting sl e 5 61 clock setting Set system time administrator june 1st 2009 20 09 Operate as 3s gt administrator password gt gt 4 gt 1 gt year gt month day hour minute gt Example set the time to 20 09 1st Jun 2009 Press 3s Enter Y M D H M press back key to exit press confirm key to save gt 9 8 lela l 2009 v 06 0 Io 20 09 gt 0 9 gt 0 6 gt 0 1 gt 2 0 gt 0 9 According to flash of Y M D H Min on screen enter 09 06 01 20 09 by turn He gt eetscet Save setting Indication Considering the convenience for user dr know the alarming time please set the time same as location time Usermanual System setting 5 62 Entry delay setting the period from system is triggered to panel start alarming default Value is 10s E g Setthe delay time as 9s Press and hold on for three seconds q Enter the delay time Press back ke
28. pliance Usermanual Introduction 24 25 26 Wired wireless zone real time monitoring active the real time monitoring function then if zone with trouble when doing arm disarm operation the panel will indicate zone fault Wireless signal repeat function via our made wireless repeater panel enable to receive signal from wireless detector from along distance Wireless detector low battery real time warning if wireless detector low battery it will send signal to panel every one or two hour or when alarm happens panel will sound dee dee and on the LCD screen low battery icon and zone number will display And panel will also report to the CMS and preset follow me phone 27 Tel line off and wireless transfer function panel make alarm or under arm 28 29 30 31 status but find out that Tel line off panel will send signal to preset neighbour panel and the neighbour panel report alarm instead Enable the panel sire by pressing the emergency key on the panel or the remote To set built in siren enable or disable when presspanic button on remote or panel keypad please referto adaptor 5 8 Require user password before enter remote control Gsm alarm function GSM alarm report to userand alarm report to CMS in CID Usermanual C Product introduction 1 2 About panel gt LCD screen 12V Arm Disarm Alarm Microphon
29. s signal relay trans mitting Usermanual al Easy setup and operation Chaptor Ill Easy setup and operation 3 1 Factory default setting Below are factory default of ST 1V control panel you can keep the default setting or modify GSM function ineffective yx Administrator password 9876 yx user password 1234 yx Entry and exist delay 10s yx Monitoring time 10s yx Cycle dial out to make alarm 5 times yw Ringing times to pick phone call automatically 7 times Cafter ringing 7 times the panel will take the phone call automatically yx TEL line cut off inspection function effective yx Arm disarm message report to CMS function ineffective yy Timing arm disarm option ineffective yx Auto arm disarm time CMS timing inspection time both are zero yx Alarm type of siren whistle during alarm all the time burglar alarm perimeter alarm fire alarm gas leak alarm and user defined alarm type XAll phone number and user code are empty yxSiren type of panic zone is silent yx Wired zone is disabled zone default set Pan zone type siren ring Burglar zone it is effective only under away arm status ineffective under disarm and home arm status 01 delay Yes Perimeter zone delay zone it is effective under arm status 02 burglar Yes ineffective under disarm status Gas leak fire emergency zone it is effective under any status 03 burglar Yes Door bell zone Give ringing tone when trigger u
30. ser code la J 2 KD enter 4 digit user password press back key to exist press confirm key to confirm 4 3 Voice alarm phone setting xxxx enter 4 digit new password user code la 3 enter voice alarm phone setting for details please read P 23 chaptor 5 5 4 4 Zone setting effective or ineffective user code Di 6 4 Please choose press 1 J set off to confirm 4 enter the zone from 1 40 to modify press back key to exist press confirm key xx 1 to set on press 0 to User manua System setting ChapterV System Setting We will introduce the function setting of ST Vseries A We are not responsible to any problem which caused by user wrong operation 5 1 Setting When set system on the keypad key with both delete function with confirm function Arm key with back exist function Every time press a key the panel will sound effective indica tion speech Every time finish one operation the panel will sound corresponding speech indication anyway it is wrong or right operation If setting under advanced menu after finish setting please press key to back to previous menu to continue other setting Under disarm status Press key and hold on for 3 seconds to enter setting sstatus Enter administrator password then press the corre sponding key to enter option se
31. swer or get the call connected but make ineffective operation the panel will continue the alarm reporting After the phone call get connect user make effective operation but do not press lto canel alarm or press 0 to hung up the panel will call other pre set phone A Play the recorded voice mess Alarm receiving age first then sound Cancel the alarm press 1 N Check alarm zone press 2 Listen to the spot press 3 Alarm report gt FN off hook Disarm the system press 4 Arm the system press 5 Activate the hoot press 6 Play the zone address recording press 7 The panel will dial the preset voice number Sal sei Hand up press 0 3 4 Remote phone control User can remote control the system by phone call After the preset ringing times then panel will off hook the phone then enter the 4 digit user codes according to voice prompting and operate as per the voice prompting 25 setup and operation N B Users to call landline phones For example the phone Enter the user code rings 7 times After 7 according to voice times ring the panel will prompting automatically off hook S 4 alarm system welcome your calling please input your password System arm press system disarm press2 inquiry the system status press 3 X listen to the spot 4 digital user password control the electrical switch press 5 Inquiry the e
32. to the panel to achieve control the panel remotely Default value is 7 times Example Setringing time as 8 Press and hold on for 3 seconds gt Enter ringing time If set gt 98764 gt 4 SH prone Press back to exit press confirm or gt E o see to save the setting Enter 2 digit number from 0 to 99 add 0 if lower than 10 Like 9 enter as 09 Note Here user can set ring times from 0 99 When setas 00 the remote control function will be disable Usermanual System setting 5 66 Detector loss test setting The time interval of detector lose or detector power off Inspection Default value is 00 Example Set inspection of detector loss or power status every 18hours Press and hold on for 3 seconds Enter 0 24hours interval on gt 9 8 7 6 4 gt 4 gt 6 Stspect Press back key to ext Press confirm key to save gt gt Setting is saved Enter 2 digit number from 0 to 24 h add Oiflowerthan 10 Like 9 enter as 09 5 67 Setcommunication inspection interval time Time interval for panel communicate with CMS Default value is 00 E g set panel communicate with CMS every 4 hours Press and hold on for three seconds 4 Enter 0 to 24 hours interval gt OST AA nanao key to exit Press confirm key to save gt 0 4 oseni Enter 2 digit number from 0 24hours add 0 if lower th
33. tting Everytime enter correct command please press to enter the advanced menu After you enter the advanced menu for user convenie nce the screen will display the default or the setting user programmed before Then the user can enter the setting he want to modify and press key to confirm If the user do not want to modify he can press to keep the former setting After this operation the LCD dis play will back to the status of enter command so that the user can enter next option setting After you finish all settings press back key to exist If after 5 minutes no any operation the panel will back to previous menu automatically dr Only under disarm status can enter system setting by pressing for3 seconds If incorrect operation during setting you can press and hold on for 3 seconds to back to previous menu 5 2 Setting on main menu Let s learn about how to enter the system and functions Please set the panel according to following method and the panel will keep the memory of your setting until you modify it again By System setting Main menu 1 set password 2 set center monitoring station 3 set alarm receiving phone number 9 8 J 76 4 system setting options x gt 4 Please enter password 5 enroll wireless device press for 3 seconds 6 set zone attribution 7 set timing arm disarm time 8 system maintenace 1 2 3 El 5 6
34. ual al Introduction gt 12 In Central Monitoring System according to quantity of users user can set 4 6 or 8 digit user code 13 Alarm type auto identify after alarm triggered on the LCD scree will display alarm zone alarm type alarm icon When connect to CMS panel will report details of alarm to CMS 14 Compatible with CMS machine support Contact ID Report alarm to CMS Report arm disarm t o CMS optional 15 Remote control Enabel via tel phone to achieve remote control system like arm disarm listen to the spot trigger siren switch on off electronic appliance etc 16 vandal proof function If try to cut off the wire between wired detector and panel or cut off the tel line which connect to the panel will make alarm 17 Anti tamper function when someone try to remove panel deliberately panel will make alarm immediately 18 Timing arm disarm Enable set 4 group time arm disarm time 19 Timing testing At preset time panel will send signal to CMS to test the panel on line status 20 Siren The panel with built in siren it can also enroll extension wireless siren Both can be settled on off when alarming 21 Follow me number The pane dials preset follow me number to report alarm message 22 Voice indication volume enable adjust on the switch 23 Electronic appliance control Enable remote inquiry and control the on off status of electronic appliance And also enable to switch on off manually electronic ap
35. ur and minute as zero U B B 4 Hour Minute L Setting is saved Enter timing disarm time Itis invalid to set bothhour and minute as zero 2 2 5 4 Hour Minute L Four set 4 timing arming disarming time User manua system setting Example Set timing arm at 6 50 AM timing disarm at 8 35 PM Enable set total 4 groups of timing arm disarm time a Press and hold on for 3S CORDOLONLORCNERILE gt 0 6 5 0 gt O chdilocatban nanan gt 2 0 minute as zero gt Save the settings Hint 4 groups of timing arm disarm can be set according to the schedule of user 5 10 System maintenance system setting Press Jand hold for 3 seconds 9 8 7 6 8 then operate follow the the voice indication system maintenance One zone 4 Two communication Four delete walking testing testing event recording 4 Enter walking testing mode press back key to exit press confirm key to confirm If communication is normal 4 Communication testing success fully If communication failure Communication testing failure q Seven play alarm address Five back to 14 Six record factory default alarm address 4 Delete all event records press back key to exit press confirm
36. y to exit press confirm key tosave gt I 8 Zo gt 44 gt 24 Administrator password gt 0 Ee serine Enter 2 digit number from 001 255 add 0 if lower than 10 Like 9 enter as 09 5 63 Exit delay setting the period from user arm to the system armed successfully This is for user s convenience to exit after arm operation default value is 10s Example Set delay time as 89s Press Jand hold on for 3s 4 Enter the exit delay time Press back key to exit press confirm key tosave gt 9 8 7 6 gt 4 4 gt 3 4 gt 0 8 9 gt E Mseninsissovss Enter 2 digit number from 001 255 add 0 if lower than 10 Like 9 enter as 09 Note Entry delay is effective just for entry exit zone Exit delay is effective just for perimeter burglar delay zone Usermanual System setting 5 64 Siren time setting the siren time after panel start alarming default value is 5 minutes Example Set the siren time as 15 minutes It s suggested not to set the siren time more than 15 minutes Press and hold on for 3 seconds 4 Enter 0 to 30 minutes siren time press back to exist Press confirm to save gt 9 8 7 64 gt 4 4 gt 4 4 gt 1 5 gt Le sessa Enter 2digit number from 0 30 add 0iflowerthan 10 Like 9 enter as 09 5 65 Set the ringing time user dial the phone which connect