Home
INSTALLATION & SERVICE MANUAL
Contents
1. 1 gt Remove the unit carefully check for any damage CHECKLIST See lt fig 1 gt 1 Spigot 2 Transformer N A with CT 315 CT 315TFC amp CT 445NF 3 Countertop RO System 4 Special aerator CT 322 with 2 adapters 13 16 15 16 5 Series CT Manual Series CT Manual SPIGOT INSTALLATION Wipe the inside of the water reservoir and rinse with clean water Install the spigot as shown in lt Fig 2 gt It is important that the rubber washer be installed on the outside of the reservoir Hand tighten by turning the spigot Do not over tighten Reservoir Wall Plastic Nut Water Reservoir lt Fig 2 gt Series CT Manual FAUCET AERATOR INSTALLATION Male thread faucet Female thread faucet Z Thick Washer n Thin Washer CT 322 Special aerator Snap adapter Hose to RO Plastic collar Snap adapter CT 391 2 Wing valve lt Fig 3 gt Remove the existing aerator from the faucet and attach the new special aerator CT 322 included with the RO unit Consult lt fig 3 gt The special aerator included with the RO unit will fit most standard faucets However if the aerator does not fit your faucet consult your dealer Most hardware or plumbing stores carry a complete line of faucet adapter fittings When tightening the fitting use a pair of pliers and tighten carefully wrap tape around the jaws to prevent marring the fittings To att
2. SOLUTIONS Milky colored WAir in system Air in the system is a normal occurrence water with initial start up of the RO system The milky look will disappear during normal use within 1 to 2 weeks Slow UV Low water pressure Add a booster pump ti ee p production Y Crimps in tubing Make sure tubing is straight Y Clogged prefilters Replace prefilter Y Fouled membrane Replace membrane Water taste or WPost carbon depleted Replace post carbon ll offensi E ER ER gg Fouled membrane Replace membrane No drain water WClogged flow restrictor Replace flow restrictor Leaks v Fittings are not Tighten fittings as necessary tightened Replace a O ring WV Twisted O ring
3. INSTALLATION amp SERVICE MANUAL Countertop Reverse Osmosis Systems Series CT CT 315 3 STAGE CTA RO SYSTEM CT 315TFC 3 STAGE TFC RO SYSTEM CT 445 4 STAGE TFC RO SYSTEM CT 445P 4 STAGE TFC RO SYSTEM WITH PUMP CT D425 4 STAGE TFC RO SYSTEM DIAMOND CT D425P 4 STAGE TFC RO SYSTEM W PUMP DIAMOND CT 550UP 5 STAGE TFC RO SYSTEM W UV PUMP MEMBER N WATER PONS Manufactured by QUALITY Series CT Manual Thank you for choosing a TGI counter top reverse osmosis drinking water system With proper care your water filtration system will produce high quality drinking water for many years Read carefully and follow the instructions in this manual before installation Pay particular attention to all warnings cautions and notes Failure to do so could result in personal injury or damage to the equipment or other property System and installations need to comply with state and local laws and regulations If you have any questions please contact us at tgi tgipure com or your local TGI dealer There are many benefits from using reverse osmosis water Not only will you enjoy high quality drinking water but also will find the water unsurpassed for e Cooking Juices Coffee and Tea Ice Cubes Low Sodium Diets e Baby Formulas Weight Loss Diets Steam Irons Car Batteries e Household Plants e Windshield Washers e Humidifiers Pets e Aquariums H Aerator Q wo Transformer Countertop System lt Fig
4. Series CT Manual INSTALLATION GUIDE TANK LEVEL CONTROL TLC LAYOUT Over Flow ro Bad Pure Water lt Fig 5 gt 1 3 pin connection for sensor wire 2 2 pin connection for pump 3 2 pin connection for transformer Series CT Manual CT 315 FILTRATION PROCESS Pure Water t Feed Water lt Fig 6 gt No Part No Descriptions Service life 1 FI SED010 Inline sediment filter 6 12 months MM CTAOI15 15 GPD CTA membrane 2 3 years FI CBA010 Inline GAC filter 12 18 months Series CT Manual CT 445 CT D425 FILTRATION PROCESS Feed Water lt Fig 7 gt No Part No Descriptions Service life 1 FI SEDO10S Inline sediment filter 6 12 months 2 FI CBAO10S Inline GAC filter 6 12 months 3 MM TFF45 75 TFC membrane 35GPD CT 445 2 3 years MM TFF30 45 TFC membrane 25GPD CT D425 2 3 years 4 FI CBA010S Inline GAC filter 12 18 months Series CT Manual CT 445P CT D425P FILTRATION PROCESS as Pa p es ks Feed Water lt Fig 8 gt No Part No Descriptions Service life 1 FI SEDO10S Inline sediment filter 6 12 months 2 FI CBAO10S _ Inline pre carbon filter 6 12 months 3 MM TFF45 75 TFC membrane 35GPD CT 445P 2 3 years MM TFF30 45 TFC membrane 25GPD CT D425P 2 3 years 4 FI CBAO10S _ JInline post carbon filter 12 18 months Series CT Manual TROUBLESHOOTING PROBLEM CAUSE
5. ach the faucet snap adapter to the special aerator pull down on the snap adapter plastic collar and push onto the special aerator until it seats Release the plastic collar The plastic collar will snap into place It is important that the hose lay flat on the counter with no sharp bends or kinks This will allow the overflow failure to function properly Series CT Manual START UP Open the plastic wing valve see lt fig 3 gt two full turns counterclockwise And slowly turn on the cold water NOTE Do not allow hot water to enter the unit This will permanently damage the membrane Water will fill the unit and also flow from the bottom outlet of the wing valve Slowly tighten the wing valve until the flow of water is reduced to a fast drip or a trickle This water is called the reject water and is the water carrying away the impurities from the membrane The amount of flow required is approximately 4 6 ounces per 30 seconds 110 200 ml 30 seconds Do not completely shut off the reject water This will damage the membrane The reservoir will slowly fill The rate at which the reservoir fills will vary with water pressure and water temperature Typical water production will be _ to 1 gallon per hour Discard the first two full reservoirs before using This will insure that any loose filter material is flushed from the system prior to use NOTE 1 Do not connect to hot water 2 Do not allow to freeze 3 Do not restrict
6. the reject flow wing valve beyond 4 6 oz per 30 seconds 110 200 m1 30 seconds A Faucet B Plastic wing valve C Electrical outlet lt Es lt Fig 4 gt Typical layout of CT Series Series CT Manual HELPFUL HINTS Proper reject flow It is important that the reject water flow from the wing valve at all times This flow of reject water removes the unwanted contaminants from the membrane Restricting this flow allows the impurities to build up on the membrane and the membrane will be damaged Make sure that this flow yields 1 2 glass or cup in 30 seconds 110 200 ml 30 seconds This will protect the membrane To clean the reservoir use baking soda and a soft cloth To sanitize the water reservoir let stand for 1 hour Rinse thoroughly before using the unit OVERFLOW It is important that the hose lay flat on the counter for the overflow system to work properly Model CT 315 CT 445 CT 445P CT 550UP CT 315TFC CT D425 CT D425P Pressure 40 75 PSI 40 75 PSI 10 75 PSI 10 75 PSI Min Max pH 3 11 3 11 3 11 3 11 Temperature 40 110 F 40 110 F 40 110 F 40 110 F Product Water 15 GPD 35 GPD 35 GPD 50 GPD Recovery Rate 25 30 25 30 25 30 25 30 Rejection Rate 80 90 92 96 92 96 92 96 System Dimension 11 5x9 5x12 11 5x11x14 11 5x11x14 11 5x11x14 LxWxH in Storage Capacity 2 5 Gallon 1 25 Gallon 1 25 Gallon 1 25 Gallon oe Weight 13 15 20 23