1. VE anne aasenamnn aa a ananas memes iris 12 3 4 1 Retrieving captured images from the HS SAM 12 3 4 2 Retrieving Object 0 data from the HS SAM 12 3 5 Multiple HS SAMs connected to the same PC cccecccceeeeceeeeseeeeeeeeeeseeeeseeeeesaeeesaes 14 3 6 Changing the Object 0 data view format 14 HS SAM Gen II User Manual Great River Technology 3 of 16 1 Overview 1 1 Included with Your HS SAM Gen Il e Wall adapter 100 250VAC 50 60Hz to 24VDC e USB cable for direct connection from your computer PC or laptop to the HS SAM e LC fiber optic cable e HS SAMView2 software installation on CD ROM 1 2 Configurations A SAM comes configured either for Fiber to DVI or for DVI to fiber Cockpit display ARINC 818 ARINC 818 MU recorder or Mission computer Great River Technology ARINC 818 Great River chnolon Cockpit display Figure 1 2b DVI to fiber DVI2F 1 3 HS SAMView2 software The HS SAMView2 software offers a graphical user interface GUI to access the following features of the HS SAM Gen Il e loading and retrieval of ARINC 818 images and data to and from the unit e header management e remote unit status monitoring HS SAM Gen II User Manual Great River Technology 4 of 16 e video source manipulation test pattern DVI in static image e multiple SAM control points ar BAL HS SA V2 1 32 bit APIVL fa CERE ESS i a a 2 F af Ft L i x t su
2. Object 0 data into the HS SAM er gt ON Header ESEE Management Figure 3 3 4a Header Management button The header management button on the main GUI will produce a pop up window that can be used for loading and retrieving Object 0 frame data For Fiber to DVI versions of the HS SAM the pop up will appear as follows HS SAM Gen Il User Manual Great River Technology 10 of 16 SAM Power up Defaults stored in non volatile F AMY comnt Restore Restore M User Defaults User Defaults Factory Defaults Suto Hpdate Grable Update Anterval MO me SAM Tx Header aS Write the header editor data to the 5AM header data Clip ID 00000000 00000000 ct 0 S 00000010 Object 0 Offset 00000058 ink Pointe 00 00000000 10 et Object 2 Offset 00000068 ject Type Defined unused Vide 1 Figure 3 3 4b Header Management data displayed Header data is contained in simple text data files accessible using the Open button Once opened the data will populate the form The data can then be written into the HS SAM using the Write button Once written to the HS SAM the data will be transmitted on the outgoing ARINC 818 stream mm mm FF G Eu m f E Pr m PR m F E iE FR AnA AA A EF C attin a Elan MAMAAtALuIE TR Amt O Aata Far Fha A IC CANN 4 gt te alta f rn Le 2 T g f F F P D ma lt lt xy OT ale A OATS nier
3. in al 5 X Fa 1 SA Wwiw nu ww www EG s SA gt Se SA SE N GA a ee d De wwe w wA A L LCA a ww eS 1 LE A ew Ff AN Default Object 0 data is stored in non volatile memory on the HS SAM This data is loaded after each power up and will be transmitted on the ARINC 818 until modified by USB This default data can be changed and stored to reflect user A818 video specification requirements SAM Power up Defaults stored in non volatile RAN Commit Restore Restore User Defaults User Defauts Factory Defaults Figure 3 3 5 Power up Defaults choices HS SAM Gen Il User Manual Great River Technology 11 of 16 The Commit User Defaults will store the header data currently streaming the A818 output into the non volatile RAM This data will be used for the Object 0 data frame after each subsequent power up The contents of non volatile RAM can also be restored using the HS SAMView2 software by clicking the Restore User Defaults button In addition factory default data can be restored using the Restore Factory Defaults button 3 4 ARINC 818 DVI Receive 3 4 1 3 4 2 Retrieving captured images from the HS SAM The Get Image button can be used to retrieve images captured from the ARINC 818 input When using the Get Image feature ARINC 818 flow is temporarily halted during the image transfer over USB Therefore the images represent snapshots of the ARINC 818 video ia eari ai t a _ a ae Pasir e he Eh parton
4. ALN Great River A R N C 8 1 8 y Technology wai greatrixerteg horom aah rHS SAM Configuration Click to select 01 024319766108 00MHz RGB OISE VREA 128021024 3 1875G6 s 108 00MH2 RGB Feb l SEE HS SAM Status ink Statue zA Flow Control Ready Sune Los ON gt gt click here for larger image lt lt ORS Present LI FT LIEtBE C OFF j i F Walid dle OS Detect b Get Image Load Image LI Tt Walid z TE mae F Test Pattern i OM M Test Pattern mage Memory rel E pa Diagnostics Ab EXIT Faut C Dyl Receive OFF Management lagnostics out Figure 1 3 HS SAMView2 main screen 2 Using HS SAM in stand alone operation The HS SAM unit is completely operational without connecting to USB That is the DVI to fiber versions of the SAM will convert DVI to ARINC 818 video and will generate test patterns Similarly the Fiber to DVI versions of the SAM will convert ARINC 818 video to standard DVI video The USB connection along with HS SAMView2 software will allow users to perform additional functions such as e Loading and retrieving bmp images into the SAM e Loading and retrieving Object 0 data into the unit e Changing the default Object 0 frame values loaded from power up The HS SAM can be 2 1 Rocker switch functions The rocker switch Fig 2 1 has three positions e Reset Resets internal elect
5. ARINC 818 is valid e TX Valid The DVI or ARINC 818 output is valid e Test Pattern For units with test pattern capability test patterns are being transmitted on the ARINC 818 or DVI output e Fault An input error has been detected For Fiber to DVI versions of the HS SAM the Link Status indicators are interpreted as follows e Sync loss After the link is established green indicates a synchronous link to the ARINC 818 source Red indicates that the unit can t establish synchronization with an ARINC 818 input This may be due to the fiber being unplugged or the ARINC 818 source being of the wrong link rate e g 1 0625 Gbps vs 3 1875 Gbps e SOFi Detect Green indicates that valid start of packet indicators have been detected in the ARINC 818 input Red indicates valid start of frame indicators have been lost for several frames in a row Return to green requires 250 milliseconds of persistence e Idle OS Detect Green indicates valid Idle OS indicators have been detected in the ARINC 818 input Red indicates Idle OS indicators have been lost during packet and frame Return to green requires 250 milliseconds of persistence 3 3 ARINC 818 Transmission 3 3 1 Transmit radio button controls Flow Control Of OFF TS Source Test Pattern ON mage Memon C DWI Receive e OFF Figure 3 3 1 TX Source choices The TX Source radio buttons allow users to transmit static images loaded into the HS SAM internal
6. Great River Technology www greatrivertech com User Manual HS SAM Geni High Speed Stand Alone Module for ARINC 818 March 7 2013 Contact Information Telephone Company Fax Web Address GREAT RIVER TECHNOLOGY est distribu par TechwaY info techway fr 01 64 53 37 90 www techway fr Revision history Date Section s Description Approval 03 07 2013 Initial release M Zimmerman HS SAM Gen Il User Manual Great River Technology 2 of 16 Contents 2 3 OVI EA eee ee D A E 4 1 1 Included with Your HS SAM Gen Us vscsscstocsccacantsseancndescasndsactedeidevansnidevandedosvapatdieaednorn 4 I2 COn O a a 4 1 3 HS SAMView2 software cccccccceecccseeeeceeeeceeeeeseeeeseeeeeseeessueeeseueessaeesseeeeseueesseeeessaees 4 Using HS SAM in stand alone operation ss 5 2 1 ROCKO SWIECA TONG OM Sie cnseettemens este mmnr tenets esteem ee ee a ee ee ou 5 D SES E EOE E eee 6 Using HS SAM with HS SAMView2 Software 6 3 1 Connecting to the HS SAM via USB ce ecccecccceeeeceeeeeseeeeseeeeeseeeesaeeessaeeeseeeesseeeesees 7 3 2 Status Indicators eee near ete ne ee ner eee 7 239 AIN CES DANS AIS SION ee ee RER 8 3 3 1 Transmit radio button controls 8 go WISN RSE Hallerne a ae a ns 9 3 3 3 Loading custom images into the HS SAM 9 3 3 4 Loading Object 0 data into the HS SAM 10 3 8 5 Setting the default Object 0 data for the HS SAM eee cceccceeeeceeeeseeeeeeeeseees 11 34 ARINC 818 DVI ROC
7. M Configuration Click to select 128021024 3 1875Gbs 108 00MH2 Ree DVI2F 3668 128021024 3 1875Gb s 108 0OMH2 RGB PaBMLY 3668 HS SAM Status r Link Status Flon Control Ready Su ja Lass C ON Rx Present SOH Detect GFF Fa Valid ldle OS Ts valid ae lar T Test Pattern ils rity Test Pattern D made Memo ui Fault fF fy Aeceive GFF Figure 3 1 Selecting an HS SAM When the application launches it will detect all HS SAM units that are connected by USB These units will be displayed in the HS SAM configuration window in the order they were connected newest at bottom as shown above Simply click on a unit in the list to connect to it by USB 3 2 Status Indicators Once connected the HS SAMView2 Status LEDs will become active as shown below HS SAM Status B Ready i Ais Present M RX Valid M Ts Vald H Te Pattern M Faut Link Status i Sune Lass E S0Fl Detect Fi Idle O8 Detect Ts Source mage Memory fe Dy Receive Flow Control u i OFF Test Pattern ON OFF Figure 3 2 Status LEDs in SAMView2 shown in a fiber receiver configuration There are six HS SAMView2 status lights e Ready The USB connection has been made and is operational HS SAM Gen II User Manual Great River Technology 7 of 16 e RX Preset The unit has detected a DVI or ARINC 818 video output e RX Valid The input video source either DVI or
8. fra ne nus Poses el tae LS ee at ie oe Fa 4 gt click here for larger image lt lt Get Image Load Image Figure 3 4 1 Get Image button A thumbnail of the loaded image can be viewed in the HS SAMView2 GUI and enlarged to full size in a separate pop up window Once the image is retrieved it can be saved to a bitmap file Retrieving captured images from the HS SAM DVI Image Receive process follows exactly the same procedure Retrieving Object 0 data from the HS SAM The header management button on the main GUI will produce a pop up window that can be used for loading and retrieving Object 0 frame data HS SAM Gen II User Manual Great River Technology 12 of 16 Header M anagement Figure 3 4 2a Header Management button For Fiber to DVI versions of the HS SAM the pop up will appear as follows M Header Pere i SAN Posver Up D fauts stared In non volatile RAM Commit Restore _ Restore User Defaults Liser Defauits Factory Default t 00000103 pe bject 0 Si 00000010 Object 0 Offset 00000058 1us 00000000 00000000 ink Pointer SPDY Index 00000000 00240068 00000000 SPDY Index D000 denses Prose fine 110 wes LE Figure 3 4 2b Recovered header data Header data recovered from the incoming ARINC 818 stream can be read from the HS SAM using the Read button The retrieved data will populate the form as shown above This data can then be saved in a simple tex
9. memory or to transmit video from an external live video source e g DVI to fiber or Fiber to DVI The flow control radio buttons allow users to turn of the transmitter In the case of DVI to fiber units this will cause the unit to transmit Idle OS on the ARINC 818 and in the case of Fiber to DVI units to transmit a blue screen on DVI HS SAM Gen Il User Manual Great River Technology 8 of 16 3 3 2 Transmit test patterns 3 3 3 Most firmware versions of the HS SAM have built in test patterns that can be turned on from the HS SAMView2 software radio buttons or from the rocker switch on the HS SAM unit Test Pattern ON C OFF EEE Figure 3 3 2a Test Pattern radio button The typical test pattern is gray scale with scrolling lines as shown below Figure 3 3 2b Gray scale test pattern Loading custom images into the HS SAM The Load Image button can be used to load any bitmap image into the internal memory of the HS SAM This bitmap image will be automatically resized for the resolution of the ARINC 818 interface Once loaded the image can be transmitted on ARINC 818 HS SAM Gen II User Manual Great River Technology 9 of 16 gt click here for larger Image lt lt Get Image Load Image Figure 3 3 3 Load Image button A thumbnail of the loaded image can be viewed in the HS SAMView2 GUI and enlarged to full size in a separate pop up window 3 3 4 Loading
10. ronics and returns all ARINC 818 outputs to idle e Run Accommodates normal operation HS SAM Gen II User Manual Great River Technology 5 of 16 e Test Pattern Transmits canned test pattern video instead of source video to ARINC 818 or DVI output only in units with test pattern capability Status lights Rocker switch Figure 2 1 Settings and status 2 2 Status LEDs There are six LED status lights e Power The unit is currently powered and ready e RX Preset The unit has detected a DVI or ARINC 818 video output e RX Valid The input video source is valid e TX Valid The DVI or ARINC 818 output is enabled e Test Pattern For units with test pattern capability test patterns are being transmitted on the ARINC 818 or DVI output e Fault An input error has been detected 3 Using HS SAM with HS SAMView2 Software Once installed the HS SAMView2 software can be run from the start menu as follows Windows Update fan Programs IE Accessories t Ty Gr athiverTech a Matrix 2 Documents HE Milinx ISE Design Suite 12 4 gt lt ARINCE18 4 Settings ka aal Figure 3 HS SAMView2 from start menu fe HSSAMVIeWw HS SAM Gen II User Manual Great River Technology 6 of 16 3 1 Connecting to the HS SAM via USB AT DA HS SAMView2 V2 1 32 bit API VL1 A A Great River gt y Technology AA NAT or tatriverte ch oom HS SA
11. t data file using the Save button HS SAM Gen II User Manual Great River Technology 13 of 16 3 5 Multiple HS SAMs connected to the same PC When multiple HS SAMs are connected to a single PC the HS SAMView2 software will list each of them in the Configuration box User can click on one of the units listed to connect to that HS SAM HS 54M Configuration Click to select 128041024 1 0625Gbrs 105 00MHz MONO F2ZDYT 3661 28041024 1 0625Gb s 108 00MHz MONO DWI2F V366 HE C Akdi Chshris bP i Cleves une Figure 3 5 Multiple SAMs listed in the HS SAM Configuration box All status indicators radio button controls image and data transfers will target the particular unit that is selected in this window 3 6 Changing the Object 0 data view format The HS SAMView2 software provides a way to customize the view of the Object 0 frame data so that data can be more easily interpreted This is accomplished using hfd files The HS SAMView2 will automatically use the default hfd file to define the fields and labels for the header form The typical default hfd view appears as follows HS SAM Gen II User Manual Great River Technology 14 of 16 Factory D fauts Interval 0e mel Figure 3 6a Typical default hfd view Under Format File the Open button will allow you to choose a new format file for the data hfd j SAM Power up D eo Read a header Format file into to header editor Figure 3 6b The Open but
12. ton under File Format HS SAM Gen II User Manual Great River Technology 15 of 16 Look int Headers 4a mi Ej E airincets hd E asv1 hfd del Type HED File eS FCa Date Modified 3 15 2006 4 19 PM Size 3 00 KB Files of type Format Files hd Cancel Figure 3 6c Creating a default format A Any number of format files can be created and used with HS SAMView2 To make one of these format files the default file for the HS SAM View software simply change the name of the desired file to default hfd Contact www techway fr TECHWAY S A S 19 Avenue de Norv ge B t Oslo Villebon sur Yvette 91953 Courtaboeuf Cedex France T 33 0 1 64 53 37 90 F 33 0 1 64 53 17 74 HS SAM Gen Il User Manual Great River Technology 16 of 16
Download Pdf Manuals
Related Search
Related Contents
ATALOG - Surly Bikes 取付説明書 - マックス Modifizieren Cycle Analyst V3.0 Unofficial User Guide MINERALWERKSTOFF Malathion 50 - KellySolutions.com Manuel d`Instructions PL-550-1 Septembre 1998 Copyright © All rights reserved.