1. On PK5508 PK5516 RFK5508 RFK5516 keypads the zone light will turn off to indicate that the zone is not Te To exit bypassing mode and return to the Ready state press Trouble Conditions Ly When a trouble condition is detected the Trouble A or System indicator will turn on and the key pad will beep every 10 seconds Press the key to silence the beeps Press 2 to view the trouble condition The Trouble A or System indicator will flash The corresponding trouble will be repre sented by numbers 1 8 ES conan ES conan Service Required 1 Low Battery 2 Bel Circuit 3 System Trouble 4 Sys Press 1 for att Tamper 5 Module n 6 RF Jam Detected Call for service more details 7 PC5204 Low Battery 8 PC5204 AC Failure the building and or neighbourhood has lost electrical Loss of AC Power power the system will continue to operate on battery Call for service for several hours te Line The P has detected that the telephone line is dis a to Com The system attempted to communicate with the moni municate toring station but failed This may be due to Trouble 3 C2 for service EEn or Zone The system is experiencing difficulties with one or more a sensors on the system Press 5 to display the zone a Sensor or Zone The system has detected a tamper condition with one 7 Comments Call for service for service or more sensors on the system P
2. PK5500 RFK5500 RFK5564 use the lt gt scroll keys to find the menu option and press to select Enter the time in 24 hr format HH MM followed by the date MM DD YY Press to exit programming NOTE If you have an LCD keypad your installer may have programmed your system to display the time and date while the keypad is idle If this is the case you can press the key to clear the date and time display Bypassing Zones Use the zone bypassing feature when you need access to a protected area while the system is armed or when a zone is temporarily out of service but you need to arm the system Bypassed zones will not be able to sound an alarm Bypassing zones reduces the level of security If you are bypassing a zone because it is not working call a service technician immediately so that the problem can be resolved and your system returned to proper working order Ensure that no zones are unintentionally bypassed when arming your system Zones cannot be bypassed once the system is armed Bypassed zones are automatically cancelled each time the system is disarmed and must be bypassed again if required before the next arming NOTE 24 hour zones can only be unbypassed manually NOTE For security reasons your installer has programmed the system to prevent you from bypassing certain zones e g smoke detectors Bypassing Zones with a PK5500 RFK5500 RFK5564 Start with disarming the system T 2 3 Press to ent
3. WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be carefully read PC1616 PC1832 PC1864 User Manual PowerSeries v4 6 and higher SECURITY SYSTEM Arming amp Disarming the System V Arming Turning On Setting Close all sensors i e stop motion and close doors The Ready w indicator should be on To arm press and hold the Away Key CAD fo Vor enter your Access Code or press 0 to Quick Arm During the setting state exit rr 1d Ready wv indica tors will turn on and the keypad will sound one per second You now have seconds to leave the premises please check with your installer a have this time programmed To cancel the arming sequence enter your access code Away Arming Turned On Set VA When the exit delay is completed the alarm sy tem is armed set and this ts indicated on the keypad as follows the Ready w indicator will turn off the Armed indicator will remain on and the keypad will stop sounding Quick Exit If the system is armed and you need to exit use the Quick Exit function to avoid disarming and rearming the system Press and hold the Quick Exit key CB for 2 seconds or press 0 You now have 2 minutes to leave the premises through your exit door When the door is closed again the remaining exit time is cancelled Bell Siren Sounds After Away Armin
4. er the function menu The keypad will display Press for lt gt Zone Bypass Press 1 or 9 then your access code if required The keypad will display Zone Search lt gt Zone Name Enter the two digit number of the zone s to be bypassed 01 64 You can also use the lt gt keys to find the zone to be bypassed and then press to select the zone The keypad will display Zone Search lt gt Zone Name B will appear on the display to show that the zone is bypassed If a zone is open e g door with door contact is open the keypad will display Zone Search lt gt Zone Name O If you bypass the open zone a B will replace the O 4 D To unbypass a zone enter the two digit number of the zone s to be bypassed 01 64 You can also use the lt gt keys to find the zone and then press to select the zone The B will dis appear from the display to show that the zone is no longer bypassed To exit bypassing mode and return to the Ready state press Bypassing Zones with a PK5508 PK5516 PK5501 RFK5508 RFK5516 RFK5501 iF 2 3 4 Disarm the system Press 1 then your access code if required Enter the two digit number of the zone s to be bypassed 01 64 On PK5508 PK5516 RFK5508 RFK5516 keypads the zone light will turn on to indicate that the zone is bypassed To unbypass a zone enter the two digit number of the zone 01 64
5. g Audible Exit Fault In an attempt to reduce false alarms the Audible Exit Fault is designed to notify you of an improper exit when arming the system in the Away mode In the event that you fail to exit the premises during the allotted exit delay period or if you do not securely close the Exit Entry door the system will notify you that it was improperly armed in two ways the keypad will emit one continuous beep and the bell or siren will sound Your installer will tell you if this feature has been enabled on your system If this occurs 1 Re enter the premises 2 Enter your access code to disarm the system You must do this before the entry delay timer expires 3 Follow the Away arming procedure again making sure to close the entry exit door properly See Away Arming Turned On Set Arming Error An error tone will sound if the system is unable to arm This will happen if the system is not ready to arm i e Sensors are open or if an incorrect user code has been entered If this happens ensure all sensors are secure press and try again Please check with your installer to determine if arming is inhibited by any other means Disarming Turning Off Unsetting Vara Enter your access code to disarm anytime the system is armed Armed indicator is on The key pad will beep if you walk through the entry door Enter your code within seconds to avoid an alarm condition please check with your installer to have this t
6. ime programmed Disarming Error If your code is invalid the system will not disarm and a 2 second error tone will sound If this hap pens press and try again Stay Arming Partially Turning On Part Setting Ask your alarm company if this function is available on your system Stay arming will bypass the interior protection i e motion sensors and arm the perimeter of the sys tem i e doors and windows Close all sensors i e stop motion and close doors The Ready w indicator should be on Press and hold the Stay key CAD for 2 seconds and or enter your Access Code and do not leave the premises f your installer has programmed this button During the set ting state exit delay active the Armed and Ready wv indicators will turn on When the exit delay is completed the alarm system is armed set and this is indicated on the keypad as follows the Ready w indicator will turn off the Armed indicator will remain on and the key pad will stop sounding The Armed i indicator and Bypass or System indicator will turn on The system will automatically bypass certain interior sensors i e motion sensors NOTE For SIA FAR listed panels the Stay Arming Exit Delay will be twice as long as the Away Arming Exit Delay Night Arming To fully arm the system when it has been armed in Stay Mode press 1 at any keypad All interior zones will now be armed except for devices programmed as Night Zones Night zones are
7. only armed in Away mode this permits limited movement within the premises when the system is fully armed Ensure that your installer has provided you with a list identifying zones programmed as night zones When the interior zones have been activated i e 1 you must enter your access code to disarm the system to gain access to interior areas that have not been programmed as night zones No Entry Arming This allows the system to be armed without an Entry Delay from zones that normally have one An entry through any zone will then create an instant alarm 1 Check that your system is ready to be armed Ready light is ON 2 Press 9 then your access code The Armed light flashes as a reminder that the system is armed and has no entry delay e The keypad sounds fast beeps e The keypad displays Exit Delay in Progress 3 The system is now armed in Stay mode Silent Exit Delay If the system is armed using the Stay key Cg Programmable Function Key or using the No Entry Arming method 9 access code the audible progress annunciation keypad buzzer will be silenced and the exit time will be doubled for that exit period only CP 01 versions only Time amp Date Programming Press 6 plus your Master Access Code or press the time programming function key programmed by your installer If you have a Time and Date trouble press 8 from within the trouble menu Press 1 to select Time and Date When using the
8. ress 6 to display the Call for service zone The system has detected a low battery condition with one or more modules sensors on the system Continue to press 7 to display the zone keypad wireless key s and RF Delinquency low battery conditions Press 7 again to see zone troubles Loss of Time amp If complete power was lost AC and Battery the time Re program Time amp Date Date and date will need to be re programmed Caan Tamper Sensor or Zone Low Battery Call for service Door Chime Entry Exit Beeps K To turn the door chime function on or off press and hold the Chime key C amp _ for 2 seconds or press 4 Access Code Programming AK In addition to the Master Access Code you can program up to 94 additional User Access codes access codes 1 48 for PC1616 access codes 1 72 for PC 1832 and access codes 1 95 for PC1864 Press 5 plus your Master Access Code The Program or System indicator will begin to flash and the Armed indicator will turn on Enter the 2 digit number to be programmed i e 06 for user access code 6 enter 40 for the Master Access Code When using the PK5500 RFK5500 RFK5564 use the lt gt keys to find the specific code and press to select Enter the new 4 or 6 digit access code or press to erase it When programming is complete enter another 2 digit code to program or press to exit For systems using multiple partitions area
9. s access codes can be assigned to specific or multiple parti tions areas Please contact your alarm company for details The access codes have programmable attributes which allow zone bypassing remote access using the ESCORT5580TC or one time use activation When using 6 digit access codes the minimum number of variations of access codes are 20833 for the PC 1616 13888 for the PC 1832 and 10638 for the PC 1864 Access Codes Z7 5 Master Code when disarmed The 5 User s Programming command is used to program additional access codes User Codes User Codes 1 48 are available for the PC1616 User Codes 01 72 are available for the PC 1832 User Codes 1 95 are available for the PC 1864 Master Code Access Code 40 The Master Code can only be changed by the Installer if pro grammed Supervisor Codes These codes are always valid when entering the 5 User Code Program ming section However these codes can only program additional codes which have equal or lesser attributes Once programmed the Supervisor Codes receive the Master Code s attributes These attri butes are changeable Any User Code can be made a supervisor code by enabeling User Code Attri bute 1 please see below for details Duress Codes Duress codes are standard User Codes that will transmit the Duress Reporting Code whenever the code is entered to perform any function on the system Any User Code can be made a Duress Code by enabeling User Code At
10. tribute 2 please see below for details NOTE Duress codes are not valid when entering 5 6 or 8 sections NOTE Access codes cannot be programmed as a duplicate or as a Code 1
Download Pdf Manuals
Related Search
Related Contents
User Manual - River Park, Inc. manual de usuario de la base de datos la ley nexus.com Edital Pregão 036/2015 User Manual - Hitachi Solutions America MXT-0411 - Esmerilhadeira 5 MN IDMS Capital Investment Projects User Manual Bedienungsanleitung Manual de usuario Votre avantage Cables Direct NLRB-399C PATA cable Copyright © All rights reserved.
Failed to retrieve file