1. women peaking in prevalence between the ages of P Approximate Dimensions 30 and 50 92mm x 32mm x 32mm C g e Weight incl The Tenease device generates high frequency mechanical vibration as haiteriesi 606 0088 opposed to electromagnetism electrical current or shockwaves It is Openia Cordini believed that pain is transmitted as impulses in the large sensory fibres of 5 C to 40 C lt 90 RH Symbol Descriptions the body By applying a vibration to the area of pain it interacts with the e Storage Transport Conditions pain impulse transmissions causing disruption The vibration is effectively 0 C to 45 C lt 90 RH scrambling the sensory impulses to the extent that they cannot be e Auto Time Setting interpreted as pain signals by the brain 10 minutes Address of Manufacturer Caution Consult Accompanying Documents Type B Applied Part Several studies have investigated the use of vibration therapy to treat acute Upper and Lower Storage and chronic musculoskeletal pain in various parts of the body The i Conditions published study Pain Alleviation by Vibratory Stimulation by Lundburg Nordemar and Ottoson from Karolinska Hospital in Stockholm shows that Consult Instructions for Use vibration therapy is an effective treatment for both chronic and acute pain On Off Button Op gt PE It also shows that it is more effective in relieving Tennis Elbow pain than TENS it is also thought that h
2. Introduction Thank you for purchasing your Tenease mobile pain relief device The Troubleshooting Warranty Battery Information Tenease is the first device specially designed for the alleviation of the pain M a A el eins ME O UISS AA OET p Y g P the batteries are not spent and are supplied with the unit Remove the ne associated with Lateral or Medial Epicondylitis more commonly referred inserted in the correct orientation If the batteries if the product is not in use for ee 4 Nr to as Tennis or Golfer s Elbow unit still does not function when the prolonged periods Remove spent J a l mobile pain relief start stop button is depressed the unit batteries from the unit Do not mix should be returned to the manufacturer different types of batteries or old and button to start the treatment This operates the device for a period of 10 new Dispose of batteries safely Please read the enclosed Terms and Conditions for more information The unit is designed to be used for a maximum Strap the device to the appropriate part of the elbow and press the start Batteries should be handled by an adult keep out of the reach of children minutes Multiple treatments can be consecutively administered with a maximum of 3 treatments a day This treatment pattern has been shown to relieve the pain associated with Epicondylitis for as long as 4 to 6 of 3 treatments a day Excessive use of Warning If batteries leak avoid contac
3. igh frequency mechanical vibrations applied P d b ies f J A p tenease I mobile pain relief locally to an injured tendon may stimulate the formation of new blood vessels This increases the blood supply to the afflicted tendon and ineering Lta associated muscles and joints potentially accelerating recovery although this has yet to be clinically substantiated r COUNT Les AMPDAHES anual l eee Manufactured in Croriarncay huyu MIC ltd Camngnny ranictratinn nn RIAAN i In Guernsey by MLE Ltd Com pany registration NO 91009 User iV Doc Ref IFU_02 Revision 3 Date 21 01 10 Instructions for Use 1 Parts The product consists of a Tenease unit strap and 2 x AAA batteries Tenease _ y 4 YY E Batteries Cleaning Instructions Wipe the outer unit with a dry cloth The strap can be washed in warm soapy water Do not immerse unit in water 2 Preparation for Use The unit requires 2 x AAA batteries included To insert the batteries push down on the Tenease logo on the battery cover while applying pressure to the rear of the unit The battery cover should easily unclip so it can be removed Insert the batteries provided taking care to insert in the correct orientation At the back of the battery compartment the terminals are identified with a and Warnings and Safety Before using the device please read and understand the following warnings to e
4. nsure the safe and correct use of the device and to prevent any injury e Ensure that there is no leakage from batteries If batteries show any evidence of leakage see section Battery Information e Ensure that batteries are installed correctly e The device is designed for use on the elbow and lower arm do not use on any other part of the body 3 Using the Unit In order to optimise the performance of the device the green protrusion on the lower side needs to be placed over the area where pain is of the unit being experienced The strap is then secured in order to hold the device in place while not restricting the blood flow to the lower arm by over tightening The green start stop button on the upper front surface is then depressed in order to activate the unit on a 10 minute cycle working correctly The Tenease can be stopped or started manually at any time by depressing the start stop button 4 Fitting the Unit Fibrous side Insert arm here Thread the strap through the slot below the battery compartment with the fibrous side facing the battery compartment Loop the end of the strap through the black end buckle and place on the arm with the front tapered end of the unit pointing towards the shoulder If you feel unwell or experience any discomfort at any time stop using the device immediately If you notice any reddening of the skin stop using the device immediately Only apply the de
5. quipment requires special precautions regarding electromagnetic compatibility EMC and must be installed and used according to the instructions contained in this manual Portable or mobile radio communication equipment may affect medical electrical equipment
6. t hours Before use please read all of the instructions in this user manual the unit beyond the recommended with skin In the event of contact wash carefully and retain for future reference treatment cycle can result in damage to immediately with copious amounts of the mechanical parts and render the water If irritation persists seek medical How Does Tenease Work manufacturers warranty invalid The unit assistance Epicondylitis is a common cause of elbow pain characterised by pain over Oe NCO Vane luce oa alls j P Y p i A i and any attempted repair or modification Disposal the outer side of the elbow which may radiate down the forearm Despite to the unit will invalidate the warranty This device is covered by the WEEE the names Tennis and Golfer s Elbow Epicondylitis does not just afflict This does not affect your statutory rights regulations that require manufacturers to tennis or golf professionals In fact this common elbow problem affects ae collect waste electrical equipment for around 3 of the population and is most often associated with work Specification reye ing alapos p ee ie o R a e Power Source charge collection disposal of this related activities Although racquet sports are more prone to the condition DC 3 0V x2 AAA batteries product please call 0845 680 9635 or they account for only 10 to 15 of all sufferers Epicondylitis is equally e Frequency 150Hz nominal visit our website www tenease com common in men and
7. vice to normal skin If suffering from a skin condition or new scar tissue is present in the area of application seek medical advice before use Do not disassemble repair or modify the device in any way as this will invalidate the warranty and may lead to malfunction of the device or an injury Do not use the device while sleeping It is recommended that the Tenease is used for 30 minutes each day representing 3 full cycles Epicondylitis is now known to be caused by a lack of inflammation of the tendon As inflammation is caused by the device to encourage blood flow and tendon repair you may experience some soreness around the elbow area when first using the device This is normal and a sign that your device is Start Stop Button Battery Cover Strap Slot Vibratory Head Pull strap down to tighten Press here The unit can now be secured by folding the Velcro strap back on itself and attaching the end of the strap onto the fibrous surface Identify the area of pain and place the green vibratory head of the unit directly over this point The unit can now be operated by pressing the green start stop button Do not immerse the device in water or any other fluid Do not throw or drop the device from a height The unit should not be used if any physical damage is evident e Do not use any chemicals to clean any part of the unit e Only to be used by persons over the age of 16 years old Medical electrical e
Download Pdf Manuals