1. Hysteresis for Alert values Alert get raised only if Hysteresis is satisfied 34 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX None Absolute Percentage Default None Valid for sys reset sys storag and Tags Hysteresis Value to use for computing Hysteresis Valid for sys reset sys storag and Tags Delay period to wait before raising the Alert Alert condition should hold True through the delay period Otherwise Alert is reset 9 3 2 3 Alert Actions Various actions such as Notify Server SMS Email Update Tags etc can be performed based on Success Failure of an Alert To configure select an Alert and click a relevant action button 9 3 2 3 1 Notify To send notification to WebFRONT server check Notify checkbox in the Alert Action handler Success handlers 9 3 2 3 2 SMS User can choose to send SMS notification for an Alert 35 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX Success handlers Sms Email Tags Ok Cancel Option Description Configure Modem to Messaging mode See Section O SMS will only be sent if a GPRS modem is detected by device 9 3 2 3 3 Email User can choose to send Email notification for an Alert Success handlers sl Sms Email Tags Option Description 4 Recipients emails separated by Semi Colon 36 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX Carbon Copy Recipients emails separated by S
2. 5 1 Widgets Radial Analog Gauge v Option Description Visualization Widget Types Radial Analog Gauge Rectangular Analog Gauge VU Meter Thermometer Liner Meter Digital Meter Led Tank Power Switch Use this to toggle Output Default Radial Analog Gauge Tag name to bind with Widget 9 5 2 Widget Properties Option PDescription gt gt gt 43 ver 1 6 0 0 MemLS99ER User Manual LadderLOGIX Type Tag Color Min Max Steps Major Major Ruler Steps for Widget Minor Minor Ruler Steps for Widget Range Green Maximum Rule Value for Green range marker Yellow Maximum Rule Value for Yellow range marker Maximum Rule Value for Red range marker Size amp Position Height Height of Widget in pixels Width Width of Widget in pixels Left Left position of Widget in pixels Top Top position of Widget in pixels Title Text Dock Docking position for Title text top center show title on Top Center of Widget bottom center show Title on Bottom Center of Widget Show hide Title on Widget 44 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX 9 6 Trend Settings Trend Settings is a WYSIWYG What You See Is What You Get designer where you can design visualization screen with Trending charts LO9JIER Option Description Refresh Rate Rate at which data is refreshed from server Canvas Size in Width x Height for Monitor View 9 6 1 Trend A Trend is a graphical repre
3. device See Section 6 5 e Discover the device using AutoDiscovery ustility See Section 7 1 e Log onto Web UI See Section 8 2 e Goto Control Panel gt IO Mapping screen and Configure and Save Tags and Alerts See Section 9 3 e GotoControl Panel gt Settings gt System Settings 5 1 As Cloud WebFRONT Data logger e Configure and Save Mode Setting See Section 9 2 2 1 o Cloud Connector On o Gateway Mode Send o Loop Continuous o Loop Interval 19 sec o Workflow Disabled e Configure and Save Server Settings See Section 9 2 2 1 e Power Off and Power On the device 5 2 As FTP Data Logger e Configure and Save Mode Setting See Section 9 2 2 1 o Cloud Connector Off o Gateway Mode Log o Loop Continuous o Loop Interval 19 sec o Workflow Enabled e Configure and Save Logger Settings See Section 9 2 2 8 e Goto Control Panel gt Workflow See Section 9 4 o AddMove File Task Trigger Any Source Folder Data Source Filename tag fdb Destination Folder Workflow o Add Custom Task Trigger Any Executable Fdb2Csv exe Arguments tag fdb Timeout sec s 2 o AddFTP Task 9 ver 1 6 0 0 MeMLOIIER O O User Manual LadderLOGIX Trigger Success Command STOR tag csv Add Delete File Task Trigger Any Folder Workflow Filename tag fdb ftp Add Delete File Task e Save Workflow Trigger Any Folder Workflow Filename tag fdb done e Power Of
4. the device connected with Cloud This will enable you to manage and configure the device online without going to the field 9 2 2 2 Server This setting lets the user configure Cloud server for the device Option Descipion CS Default webfront m2mlogger com Region WebFRONT Cloud server regions For improved performance select a region that represents best proximity to your device Default in 1 WebFRONT account name Keep Alive Timeout Duration to wait for WebFRONT keep alive message Default 30 sec Keep Alive Retry Number of keep alive retries to detect a closed WebFRONT connection Default 3 sec 9 2 2 3 Clock This setting lets user set the device calendar and clock Option Descripti n Timezone Device time zone Current Minutes 9 2 2 3 1 Toolbar Button Description Aun Manually Sync clock with NTP server 23 ver 1 6 0 0 MemLS99ER User Manual LadderLOGIX 9 2 2 4 Ethernet This is device Ethernet settings Option Description Current Seconds LadderLOGIX data logger does not support Static IP Address It can only be connected to networks with Dynamic IP Address i e network with DHCP server 9 2 2 5 Modem This setting lets user set modem options An external modem which is optional can be a GSM GPRS attached to the RS 232 9 pin DSUB interface Option BDescipion Set Modem Modes None Mess
5. DBUS Ethernet IP 9600 19200 38400 57600 115200 Status indication Power Module Status Internet Cloud Communication Status Additional Weise v Y o oOo oo Internal Storage 3000 records 5000 records Power MXPXA300 MXPXA1000 Supply to 1000 VAC RMS Communication Port Environmental OOOO Operating 0 to 55 C Temperature 13 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX Storage Temperature 10 to 70 C 30 to 95 RH non condensing 35 W x 101 H x 120 D mm 250 gms approx Molded ABS 101 Figure 2 Physical Dimensions mm 6 5 Connections MODBUS 24VDC RS485 10 BA to RS232 GSM GPRS 9600 115200 bps Ethernet USB 2 0 Host 10 100 Mbps Pen drive LAN Internet Figure 3 Field Connections 14 ver 1 6 0 0 MemLS99ER User Manual LadderLOGIX 6 5 1 RS232 GSM GPRS The 9 pin DSUB Male connector on the LadderLOGIX contains and RS232 interface This port can be used to connect GSM GPRS modem Pin Function O 1 CD CarierDetet 2 o RX Receive 3 A 4 DTR Data Terminal Ready 5 ICAA 6 DSR DataSetReady o ao tS ClearToSend 9 jRi Rnglndiato 6 5 2 MODBUS RS 485 RS 485 Line A B RS485lineB A A LadderLOGIX MODBUS slave B L B Figure 4 Normal wiring diagram for M
6. LOSS ER remote monitoring eco system User Manual LadderLOGIX Industrial Data Logger cum Cloud Gateway Revision List Revision Date Description S 1 3 0 0 27 April 2014 Match firmware release 1 3 0 0 1 4 1 0 16 June 2014 Match firmware release 1 4 1 0 1 6 0 0 1 July 2014 Match firmware release 1 6 0 0 Preface The data and illustrations found in this document are not binding We reserve the right to modify our products in line with our policy of continuous product development The information in this document is subject to change without notice and should not be considered a commitment by M2MLogger M2MLogger assumes no responsibility for any errors that may appear in this document The document uses following pictures to get the reader s attention Symbol Note Important information to avoid configuration that can cause problems and therefore should be read carefully Additional information about how to get the most out of LadderLOGIX Contents 1 Engins RAS A AS isan 6 2 SUS ole d ere 6 3 Terminology sesno ec YE VEU LE VON OPERE VENIO VEN EXE ea 7 4 How to use LadderbOGDCG iie eo eese PoyR ER VEP Ra MR VERA EE RR VR EE EREFE RE YER ESEESE 8 5 Quick Setup Instructions ccce PR COP e QUEE AA 9 5 1 As Cloud WebFRONT Data logger sccccccceccccssaaesssseeeececceeeesssuuaasssseeeeeee
7. ODBUS terminal A and B 6 5 3 Power 24VDC 24 VDC Ground 0 1 O 15 ver 1 6 0 0 MemLS99ER User Manual LadderLOGIX Power Supply LadderLOGIX 24VDC Line Voltage Figure 5 How to connect AC power 6 5 4 LED Indication Name Color Function Power Device Run O Internet No Internet nternet Connected Off eof Notmr O Red unrecoverable Error Transmission Data Reception Error ff WebFRONT WebFRONT disconnected ff 16 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX 7 Getting Started 7 1 Auto Discovery utility The Auto Discovery is a PC based configuration utility to scan the Ethernet network for connected LadderLOGIX devices so that further configurations can be made to selected device 7 1 1 Installation Download and run AutoDiscovery exe utility from http www m2mlogger com downloads htm 14050000 192 168 2 2 MXPXAJO0 MAPAASOO 00 00 00 00 00 00 1 3 0 0 Local Ares Connection v Discover Comigure Connect Drecty ao 7 1 2 Scanning devices connected over network If your LadderLOGIX device s are connected over a network then you should consider following steps Power up LadderLOGIX device and connect LadderLOGIX with network Start AutoDiscovery exe utility Select the relevant Network Adapter and select Discover To configuration a LadderLOGIX device click the Configure button to open up Web UI for the device in Web Browse
8. V GOFRTIOW E o T ET 38 9 4 1 Refer im EMT 38 9 4 2 MIEIRI IRI T UTE 39 9 4 3 Pdsksec cnc LL MA LII M C M E 39 9 5 Monitor Sete lo ce ao a a 42 9 5 1 WISE 43 9 5 2 Widget Properties arnee a eor veta et rn e debe ee 43 9 6 Trend SCENES svi A AO 45 9 6 1 Tendria 45 9 6 2 Trend PEO POE ss AA eb co db eie 45 9 7 ACCOUNT sanan e 47 9 8 MORITO Soa RANA AER RE CP E RENS Vat 48 9 8 1 MOON ab GE NE E UU UU E IU TT 48 9 9 Hioc EE 49 9 9 1 TON EE UU UR 49 9 9 2 ZOOI pea ea twee A snc ete E das 49 9 10 EETAS Ee LA nier ode cere E a 50 O ac SFE saa een RT 50 9 11 Aleister E vant ba E A T 51 oO DET Toolbars o A a ea iod esae E N 51 10 APPEAR sei oa na ales AAA 52 10 1 Filename wildcard Sien a a ttv E E LE aM saat 52 10 1 1 T SU A sates cesta daw tics acs eerta MK CM E EA E 52 10 2 FTP COMMANA ETT T TUTTI 52 dioses STOR PF 52 11 Troubleshoot s une Orte PU a Red U vh ve AAA e b tis a Crea Ee Y Ia ad RDUM e Ris 53 11 1 Power CED NOT ON ao 53 11 2 Both Run and Error LEDs blinking sein dado Ebrei da 53 11 3 Run LED ON and Error LED blinking uso doo oia 53 11 4 Run LED OFF and Error DEB ON aia 53 11 5 Connecting internet with Static IP AddressS ooooononcccnnnnnnnnnnnnnononannncnnnnnnnnnononononanannnos 53 MemLS99ER User Manual LadderLOGIX 1 Warranty M2MLogger warrants that for a period of 365 days from date of shipment of product the product shall be free from defects under normal use Under this warranty it i
9. age Data Default None Baudrate Baudrate settings in bps 9600 19200 38400 57600 115200 Default 115200 Start bits Frame start bit 1 Default 1 Data bits Frame data bits Default 8 24 ver 1 6 0 0 MemLS99ER User Manual LadderLOGIX Stop Bits Frame stop bits 1 1 5 2 Default 1 stop bit Handshake None Software Hardware Both Default Hardware Parity None Even Odd Default None Area Code to dial to ISP APN Access Point Name GPRS gateway that is given by SIM card operator 9 2 2 6 SMTP This setting lets user configure the SMTP settings to use while sending out email Option Description S Password for the SMTP server Server SMTP Server that is used for sending e mail Could be entered as IP address or domain name SMTP server port SSL SMTP server SSL settings None SSL TLS STARTTLS Default None 9 2 2 7 MODBUS This sub menu item lets the user configure the MODBUS RS 485 communication interface Make sure that the wiring is correct Option Description 25 ver 1 6 0 0 MemLS99ER User Manual LadderLOGIX UART Mode Set MODBUS transmission mode RTU Default RTUJ Baudrate Baudrate settings in bps 9600 19200 38400 57600 115200 Default 9600 Start bits Frame start bit 1 Default 1 Data bits Frame data bits Default 8 Stop Bits Frame stop bits 1 1 5 o Default 1 stop bit Handshake None Software Hardware Default Har
10. derLOGIX Integer 32 bit Integer 64 bit Float Swap Float Default Integer 16 bit Swap Float uses word swap floating notation Address Address MODBUS Address of registers to read write 0 to 65536 Data points to read write read only and MODBUS TCP Outputs MODBUS TCP Outputs Time for which device will wait for MODBUS slave to reply Default 100 ms Number of retries after which MODBUS query errors out Hysteresis Hysteresis for Tag values Tag value only gets recorded if Hysteresis is satisfied None Absolute Percentage Default None Valid for Trigger is On Change Value Hysteresis Value to use for computing Tag Hysteresis Valid for Trigger is On Change Group Specify Group name to group Tags to execute MODBUS Bulk Query Notify Server Check to send Tag value to server 31 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX 9 3 1 3 MODBUS Bulk Query LadderLOGIX device can execute bulk query over MODBUS Tags with Group are eligible for MODBUS Bulk Query 9 3 1 3 1 MODBUS UART For MODBUS UART Bulk Query is grouped by Tag Group Slave Id and Function 9 3 1 3 2 For MODBUS TCP For MODBUS TCP Bulk Query is grouped by Tag Group IP Address Host Port Slave Id and Function 9 3 1 3 3 Timeout Bulk Query obtains Timeout value from Device Settings System MODBUS Timeout See Section 9 2 2 7 9 3 1 3 4 Retry Bulk Query obtains Retry value from Device Settings gt System gt MODBUS gt Ret
11. down the files under Data folder 9 2 3 2 Logs This selection lists down the files under Logs folder 9 2 3 3 Workflow This selection lists down the files under Workflow folder 9 2 3 4 Toolbar Button Description O Folder Folder to explore Refresh Data files Delete a data file 28 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX 9 3 10 Mappings At IO Mappings screen you define Tags MODBUS queries and Alerts 9 3 1 Tags You can configure MODBUS queries as Tags LO9YIER 9 3 1 1 Toolbar Button Description S Add a Tag Edit a Tag Clone a Tag Delete Tag s Delete a Tag Group all the Tags within the same Group will be deleted Scale Add Edit Scaling for Tag 29 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX 9 3 1 2 Defining Tag MODBUS TCP Input Y Read Input Register Y Ok Cancel Option Description Type Tag Type MODBUS UART Input MODBUS UART Output MODBUS TCP Input MODBUS TCP Output Default MODBUS UART Input Function MODBUS Functions Read Coils Read Discrete Inputs Read Holding Registers Read Input Registers Write Single Coil Write Single Register Default Read Input Register Trigger Trigger for Tag to get recorded None On Change Default None Tag precision digits to 6 Slave Id MODBUS Slave Id of slave device 1 to 247 Data Type Data Type of Tag Bit Integer 16 bit 30 ver 1 6 0 0 MemLS99ER User Manual Lad
12. dware Parity None Even Default None Timeout The time that device will wait for a response from a slave before serial timeout will occur Default 1000 Retry Number of retry if an error occurs while querying data from MODBUS slave Default 3 9 2 2 8 Logger This setting lets user configure the device Tag logger 26 ver 1 6 0 0 MeMLOIIER User Manual LadderLOGIX This setting is only used if Gateway mode is Log or Send amp Log see Section 9 2 2 1 Option Description Column Separator Row Separator Rollover time Set Tag Logger mode Continuous On Change Default Continuous Column Separator to be used by logger Comma Pipe Default Comma Row Separator to be used by logger Line Feed Carriage Return amp Line Feed Default Line Feed Rollover time for the logger when it rolls over the current file and starts writing to a new file Default 5 mins Encoding Logger text encoding Default ASCII Logger always writes the file to Data directory Logger filename format tag ddMMyyyyHHmmss fdb tag fdb is the active file on which Logger is writing Any operation on tag fdb may result in device malfunction 27 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX 9 2 3 Explorer This tab lists down the files being logged on data logger User can download or delete the data files from this screen LO9YER 9 2 3 1 Data This selection lists
13. eal time data visualization 11 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX 6 About LadderLOGIX LadderLOGIX series comprises of advanced Industrial Cloud gateways that can extend any Industrial network to Cloud They enhance your capability monitor analyze and control the performance of your process remotely from any place in world These gateway devices can be easily interfaced with e Existing PLC DCS or SCADA system with an MODBUS interface e MINT Intelligent lOs 6 1 Features e Remote monitoring e Signal Scaling e WebFRONT Web SCADA Cloud e Rugged design for rough gateway Industrial conditions e Web User Interface Web UI e Compact DIN rail mounting e MODBUS RTU RS 485 amp e Plug n play MODBUS Ethernet IP e Fail safe for power failures e File Transfer Protocol FTP e Over The Air OTA upgrades e USB Pen drive data logger e 1KV isolation e Alerts SMS Email LadderLOGIX supports an RS 232 connection through a 9 pin DSUB MODBUS RS 485 through screw terminals USB pen drive through USB type A connector and 10 100 Mbps Ethernet through a standard Ethernet connector RJ 45 It can be configured via a user friendly Web interface Web UI 6 2 Mounting on DIN rail Snap On u Snap Off 12 ver 1 6 0 0 MemLS99ER User Manual LadderLOGIX 6 3 Technical Specification Communication S 2 Wire EIA RS485 MODBUS RTU Available Ports 1 x RS485 Multi drop Serial Communication 1 x MO
14. eeeesssaaaaees 9 5 2 AS dldbricuKeuu r e 9 5 3 AS USB DaltasLOBBgel riter pu b Env pir uoi db racc tai hist erc Eier See qucxiS 10 5 4 As Local Web based Data Loggelr ccsssssssssseeeeeccccccesseeesssseceeeeeeceseeeseeeassseeeeseeeeeeeess 11 6 About LADUE 10 C P OR ETT TOT T E ET TS 12 6 1 A ob RHOD ERO UO OST E ER b aA 12 6 2 Mo nting on DIN rail PD 12 6 3 Technical S OSC FC ACI OV adesse o itren cupi pax eeu bid n naim a ameter du p ome op pep 13 6 4 PVG CAAA MINE 14 6 5 CONNECUON etu sas abe ts sare sats ss poses ic rere TEL E MU CE Md 14 6 5 1 R5232 GSMZGPRS ui eode ia ELE a a E E ot A 15 6 5 2 Ya 15 6 5 3 POWER AVA A AE EEA EEA E AE 15 6 5 4 CED Indic3tlo Minerua eon e a II 16 7 Getting Started cuoc cete antodted daescaire Ue totos aaia aana iadaaa aa i ie 17 7 1 Auto Discov ry utility etoile tati 17 7 1 1 PASTA FREDO DAA UP 17 7 1 2 Scanning devices connected over NetWorK sssssesessesssreresssererossserrreesserreeesssrreresseereeee 17 7 1 3 Scanning devices connected directly oocccccccoonocnnnnnnonanonononcnnnncnnnnnnonanoncnnnconanonnnnnnns 17 8 Web UNO VETE Wi TUTTI NITET 19 8 1 Browser REQUIERE 19 8 2 O AR RI AAA onegannoed ts 19 9 User Intertd6B ninia dd 20 9 1 Control PA e e Cafe 20 9 2 Device Settings AAA AAA eae 21 9 2 1 GE MELA A RN 21 9 2 2 Ns 22 9 2 3 EPIA E 28 9 3 IO MappINES A 29 9 3 1 MAS EAN AA AAA A E 29 9 3 2 AVES METER 33 9 4 W
15. emi Colon Bcc Blank Carbon Copy Recipients emails separated by Semi Colon Subject Custom Alert Email Subject Custom message to be included in SMS Include Snapshot Include Alert Values snapshot Internet Connection required for sending email See Section O Valid SMTP settings required See Section 9 2 2 6 9 3 2 3 4 Tag User can choose to update Output Tags as an alert action Updates to Tag are immediately sent to MODBUS slaves Helpful when preventive actions have to be taken in response to an alert Success handlers m Sms Email Tags Option Description 0 0 Select a Tag you wish to update Provide a value to update to the Tag 37 ver 1 6 0 0 MemLS99ER User Manual LadderLOGIX 9 4 Workflow Workflow is collection to Tasks that execute in user defined sequential order User can configure custom workflow from this screen 9 4 1 Toolbar PButon Description d Refresh Workflow Add a Workflow Task Edit a Workflow Task Delete a Workflow Task Save Workflow Frequency Frequency in seconds to run Workflow 38 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX 9 4 2 Manage Manage Workflow Move File Y Any v Option Description Type of Workflow Tasks Move File FTP Delete File Custom Network Move Default Move File Trigger Trigger condition to start the task based on result of previous task result An
16. f and Power On the device 5 3 As USB Data Logger e Configure and Save Mode Setting See Section 9 2 2 1 Cloud Connector Off Gateway Mode Log Loop Continuous Loop Interval 10 sec Workflow Enabled e Configure and Save Logger Settings See Section 9 2 2 8 e Goto Control Panel gt Workflow See Section 9 4 Add Move File Task O O O O O O O O Trigger Any Source Folder Data Source Filename tag fdb Destination Folder Workflow Add Custom Task Trigger Any Executable Fdb2Csv exe Arguments tag fdb Timeout sec s 2 Add Move File Task Trigger Any Source Folder Workflow Source Filename tag csv Destination Folder USB Add Delete File Task Trigger Any 10 ver 1 6 0 0 MemLS99ER User Manual LadderLOGIX m Folder Workflow Filename tag fdb done e Save Workflow e Power Off and Power On the device 5 4 As Local Web based Data Logger e Configure and Save Mode Setting See Section 9 2 2 1 O O O O Cloud Connector Off Gateway Mode Log Loop Continuous Loop Interval 19 sec Workflow Enabled e Configure and Save Logger Settings See Section 9 2 2 8 e Goto Control Panel gt Monitor Settings and create a Monitor screen See Section 9 5 e Goto Control Panel gt Trend Settings and create a Trend screen See Section 9 6 e Power Off and Power On the device e Goto Control Panel Monitors orControl Panel Trends to view r
17. l Panel Control Panel is the default landing screen for the device Here you can navigate to different screens for configuration and SCADA visualizations LOSSER 20 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX 9 2 Device Settings At device settings screens you can make configuration changes to device 9 2 1 General This tab shows the general settings for device 9 2 1 1 Options Option Description o LOSSER 9 2 1 2 Toolbar Button Description OOOO E Refresh General Settings Save changes to Device Name Restart device Upgrade device firmware 21 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX 9 2 2 System This tab shows the system settings LOSSER 9 2 2 1 Mode This setting lets the user configure mode for the device Cloud Connector Switched On Off the Cloud connector Default On Gateway mode Sets the gateway mode Send send values to Cloud Log log values on local storage Send Log send values to Cloud and also log on local storage Default Send Sets the loop mode for device Continuous loops continuously Triggered one iteration when triggered Default Continuous Loop Interval Sets device loop interval Default 5 sec When the device is running Average Loop is displayed to give an approximation of actual execution time Workflow Enable Disable Workflow 22 ver 1 6 0 0 MemLS99ER User Manual LadderLOGIX It is advisable to always leave
18. lename can contain wildcards See Section 10 1 9 4 3 4 Custom This is a custom task and should only be configured after consultation from M2MLogger Custom Task Executable Name of Custom Executable to run Arguments Arguments to Custom Executable file Filename can contain wildcards See Section 10 1 Timeout Time to wait for Custom Executable to return The Custom sec s Executable will be terminated if does not returns within timeout duration 41 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX 9 4 3 5 Network Move This task moves the file from source folder to a network folder Network Move Task Option Description O Source Folder Source folder to copy file from Data Workflow Default Data Hostname of network computer Source Filename File name of source filename Filename can contain wildcards See Section 10 1 Destination Folder Shared folder on network compute where files have to be copied Make sure network computer is reachable by data logger Shared folder should have exclusive Read Write Delete rights for Everyone on network 9 5 Monitor Settings Monitor Settings is a WYSIWYG What You See Is What You Get designer where you can design visualization screen with gauges 42 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX LO9YER Description Refresh Rate Rate at which data is refreshed from server Canvas Size in Width x Height for Monitor View 9
19. on Description O O Refresh Rate Refresh Rate for Trends screen Start polling data from server Stop polling data from server Last Refreshed Timestamp of last refresh 9 9 2 Zoom To zoom the Trend chart select the desired area in the Zoom panel at the bottom of Trend chart o 49 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX 9 10 Tag Stream Tag Stream screen tabulates the latest Tag values To refresh values click on Refresh button 9 10 1 Toolbar PButon Description E Refresh Tag Stream data 50 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX 9 11 Alerts Alert screen tabulates all the Alerts raised by device LO99ER gt gt 9 11 1 Toolbar PButon Description d Refresh Alerts data 51 ver 1 6 0 0 MemLS99ER User Manual LadderLOGIX 10 Appendix 10 1 File name wildcards Filename can contain wildcards 10 1 1 Asterisk Substitute for zero or more characters Example tag fdb Successful Match tag0123 fdb Failed Match tag fdb 10 2 FTP Commands 10 2 1 STOR Accept the data and to store the data as a file at the server site Syntax STOR filename filename is the source file name See Section 10 1 FTP files will be picked from Workflow folder only The destination filename will always be same as source file name Example STOR tag fdb 52 ver 1 6 0 0 MemLS99ER User Manual LadderLOGIX 11 T
20. pport at support m2mlogger com 6 ver 1 6 0 0 MemLS99ER User Manual LadderLOGIX 3 Terminology Term Extract Description TCP IP Transmission Control TCP Transmission Control Protocol is a Protocol Internet Protocol set of rules used along with the Internet Protocol IP to send data in the form of message units between computers over the Internet HTTP Hyper Text Transfer Protocol HTTP is a set of rules for exchanging files text graphic images sound video and other multimedia files on the Web DHCP Dynamic Host Configuration DHCP is a standard protocol that Protocol automates the process of configuring network hosts by allowing hosts to obtain IP addresses and configuration parameters A device that makes it possible to transfer data between networks of Gateway different kind e g MODBUS and Internet Device A MODBUS slave unit that is connected to LadderLOGIX LadderLOGIX 7 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX 4 How to use LadderLOGIX WebFRONT App Analysis Visualization and Alerts WebFRONT Cloud i Platform DM Web UI USB Pen Drive L FTP LadderLOGIX Industrial Data Logger cum Cloud Gateway Field Interfaces MINT Intelligent IOs PLC DCS or SCADA Field Sensors and Actuators Temperature Flow Energy Humidity Figure 1 How it works 8 ver 1 6 0 0 MemLS99ER User Manual LadderLOGIX 5 Quick Setup Instructions e Make field connections to
21. priate Static IP Address Please consult M2MLogger Support for further assistance 53 ver 1 6 0 0 Head Office Techno Instrumentation India Pvt Ltd Telefax 91 11 22112232 An ISO 9001 2008 Certified Company Mobile 91 98105 54547 Plot 67 Street 1 B E mail sales m2mlogger com Friends Colony Industrial Area Web www m2mlogger com G T Road Shahdara Delhi 110095 India M2MLogger is a division of Techno Instrumentation India Pvt Ltd
22. r p pgs 7 1 3 Scanning devices connected directly If your device is directly connected to Laptop via straight cross Ethernet cable then you should consider following steps 1 Power up LadderLOGIX device Do NOT connect Ethernet cable to laptop yet 17 ver 1 6 0 0 MemLS99ER User Manual LadderLOGIX 2 Start AutoDiscovery exe utility 3 Click Connect Directly On Direct Connect Setup dialogue select the Network Adapter you will be connecting the LadderLOGIX and click Configure paure Direct Connect 2D MA I S Direct Connect Setup Auto Discovery Auto Discovery Utility to discover your Ladderl OGIX devices over Utility to discover your Ladderl OGIX devices over intranet connection intranet connection C 2014 M2MLogger All rights reserved Il C 2014 M2MLogger All rights reserved Choose Network Interface where LadderLOGIX Choose Network Interface where LadderLOGIX device will be connected device will be connected Marvell Yu m Area Con Network Interface Card is configured Please Power On and connect your Ladder OGIX device to the Network Interface Configure Configure Click Finish upon successful configuration Now connect LadderLOGIX with Laptop make sure data logger is running Select the relevant Network Adapter and select Discover To configuration a LadderLOGIX device click the Configure button to open up Web UI for the device in Web Browser CON o uj It your device i
23. roubleshoot 11 1 Power LED not ON If power is connected to device and Power LED does not glow this means e Either rated power is not connected See Section 6 3 e Or reverse polarity connection See Section 6 5 3 11 2 Both Run and Error LEDs blinking If both Run and Error LEDs are blinking this means device is running out of memory Please consult M2MLogger Support for further assistance 11 3 Run LED ON and Error LED blinking If Run LED is ON and Error LED is blinking this means the device Clock is reset Under such a condition device does not executes the Loop Please connect the device with Internet and Synchronize the Clock as per Section 9 2 2 3 11 4 Run LED OFF and Error LED ON If Run LED is OFF and Error LED is ON this means the device has encountered an unrecoverable error Generally LadderLOGIX device will restart under such a condition But if the problem persists on three consecutive restarts then device shows the status until remedial action is taken Please consult M2MLogger Support for further assistance 11 5 Connecting internet with Static IP Address LadderLOGIX Data logger only supports Dynamic IP Address i e it needs a DHCP server to allocate IP Address If you wish to install data logger in a network where DHCP server is not available consider installing a commercially available multi port router with DHCP capability between data logger and network You should configure the router with appro
24. ry See Section 9 2 2 7 9 3 1 4 Scale Tag Scaling is used to convert measured values to engineering values LadderLOGIX supports Linear Scaling Only Input Tags can be scaled Enter minimum 4 values for best result TAG Scaling Linear Save Clear 32 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX Option Description Reg Register Value Engineering Value Reg Value has precision of 6 decimal places Engineering Value has same precision as that of Tag A maximum of 10 data points can be entered 9 3 2 Alerts An Alert is an exception that has to be raised and notified when a Tag breaches its threshold LOQGER Bom 9 3 2 1 Toolbar PButon Description Add an Alert Edit an Alert Delete an Alert Add Edit Success actions Add Edit Failure actions 33 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX 9 3 2 2 Defining Alert Manage Alert Low T Greater Than Y F Mone Ok Cancel Option Description Severity Alert Severity Low Medium High Default Low LHS Left Hand Side for Alert Comparison sys reset System Reset Alert sys storage System Storage Alert Tags Input Tags Operation Alert Operation Equal Not Equal Greater Than Greater Than Equal Less Than Less Than Equal On Change Raises alert if underlying Tag has changed Default Equal Right Hand Side Value to compare with Alert precision digits
25. s obligation of M2MLogger to replace any device found defective within the warranty period and has been returned to M2MLogger by buyer at buyer s expense All shipping and insurance costs both ways are the responsibility of buyer The warranties do not include damage due to negligence improper installation or operation accident tampering with warranty seal or other conditions other than normal use which might cause the Products to fail THE WARRANTIES AND THE REMEDIES SET FORTH IN THIS SECTION ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES ORAL OR WRITTEN EXPRESS OR IMPLIED EXCEPT AS SET FORTH IN THIS SECTION M2MLOGGER MAKES NO WARRANTIES EITHER EXPRESS OR IMPLIED REGARDING ANY OF THE PRODUCTS INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY FOR A PARTICULAR PURPOSE THE ENTIRE RISK AS TO THE QUALITY AND PERFORMANCE OF THE PRODUCT IS WITH BUYER IN NO EVENT WILL M2MLOGGER BE LIABLE TO BUYER OR ANY OTHER PERSON OR ORGANIZATION FOR ANY DAMAGES INCLUDING ANY LOST PROFITS LOST SAVINGS OR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE ANY OF THE PRODUCTS EVEN IF M2MLOGGER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR FOR ANY CLAIM BY ANY OTHER PARTY 2 Support To obtain fast and simple support for your LadderLOGIX please use our website http www m2mlogger com Here you will find the latest documentation configuration utilities drivers etc You can also contact our su
26. s connected on LAN and you are having trouble discovering device using AutoDiscovery exe try disabling your Antivirus and or Firewall AutoDiscovery exe runs on Dot Net Framework 3 5 Please download and install Dot Net Framework 3 5 from http www microsoft com 18 ver 1 6 0 0 MemLS99ER User Manual LadderLOGIX 8 Web UI overview 8 1 Browser Requirement The web pages are optimized for Internet Explorer version 9 or later and Google Chrome Other browsers can work as well but the web pages might appear differently and some functionality can be limited The browser must be HTML 5 with Canvas support enabled to use pages like the Monitors and Trends If it is not please upgrade to a HTML 5 enabled browser visit http www htmL5test com 8 2 Login Open a web browser and enter the IP address of your device if you know or click on Configure button in Auto Discovery to launch Web Browser with appropriate IP address of device For example if IP Address of device is 192 168 1 2 then you should enter the text below in the address field of the browser and press enter http 192 168 1 2 Now you should see the login screen Authentication Required The server http 192 168 1 2 80 requires a username and password The server says M2MLogger User Mame Password Log In Cancel Username admin Default Password password 19 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX 9 User interface 9 1 Contro
27. sentation of Time series data One Trend can contain multiple Traces Each Trace represents one Tag Manage Trend Ok Cancel Option Description O Name of Trend Type Visualization Trend Types Line Default Line 9 6 2 Trend Properties Option Description 45 ver 1 6 0 0 MemLS99ER User Manual LadderLOGIX Type Name Data Points Show Steps Show Points Show Legends Show Filled Show Title Show Hide Title for chart 1 X Scales up down Widget values by 1 X Y Axis Min Y Axis Max Maximum value for Y Axis Height Width Left Top 46 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX 9 7 Account You change your account password from this screen Type New Password and Confirm Password and Click Change Password LOGGER Change Password 47 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX 9 8 Monitors Monitor screen lets you visualize logged Tag values as Gauges on a real time basis LOSSER Double clicking a Power Switch will toggle the output 9 8 1 Toolbar Button Description O Refresh Rate Refresh Rate for Monitor screen Start polling data from server Stop polling data from server Last Refreshed Timestamp of last refresh 48 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX 9 9 Trends Trend screen lets you visualize logged Tag values as Trending chart on a real time basis LOGGER 9 9 1 Toolbar But
28. y Starts a task irrespective of previous task being success failure Success Starts a task only if previous task was success Failure Starts a task only if previous task was failure Default Any 9 4 3 Tasks 9 4 3 1 Move File Move a file from source folder to a destination folder File Move Task Workflow Y Option Description Source Folder Source folder to copy file from Data Workflow Default Data Source Filename File name of source filename Filename can contain wildcards 39 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX See Section 10 1 Destination Folder Source folder to copy file from Workflow USB Default Workflow 9 4 3 2 FTP This task transfers a file over to FTP server FTP Task Ok Option Description o FTP Server File Transfer Server name File Transfer Server Port Username for logging on to FTP server Password for logging on to FTP server FTP command to run See Section 10 2 Only simple FTP supported SSL is NOT supported FTP files will be picked from Workflow folder only After successful FTP file is renamed to lt original filename gt ftp 9 4 3 3 Delete File This task deletes a file from source location 40 ver 1 6 0 0 MemLO99ER User Manual LadderLOGIX File Delete Task Option PDescription S Folder Source folder to copy file from Data Workflow USB Default Data Filename File name of source filename Fi