Home

Matrix 800 VA Manual

image

Contents

1. 9 8 TECHNICAL SPECIFICATIONS 10 11 S WARRANTY CARD ttt 12 Contents REV 23 05 08 N SU Ms SINE WAVE HOME UPS Kom KNOWING YOUR HOME UPS Now lets begin the journey to explore various aspect of your Su Kam Sine Wave Home UPS Welcome aboard Su Kam s Home UPS is a truly futuristic concept It works as an offline Stand by UPS having options of user selectable mains voltage narrow wide window and switch over time from mains to backup mode or vice versa lt ensures continuous supply of power from the battery bank whenever mains supply from utility power is not available meow view sss AA E On the front panel of the Home UPS there is one ON OFF power active switch and a graphic symbol panel for indications 1 MAINS ON This graphical symbol when lit indicates that incoming mains is available 2 INV This graphical symbol is lit when the incoming mains is not available and the output is from Home UPS 3 BATT CHARGING CHARGED This graphical symbol shows that the mains line is coming and side by side the charging of batteries is also taking place This graphical symbol glows intermittently during charging and glows continuously when battery is charged 4 FUSE BLOWN Mains fuse blows off when the Home UPS is operating on mains and the load connected through the Home UPS exceeds the specified limits prescribed
2. PKG ML 104 USER S MANUAL IFU SINE WAVE HOME UPS MATRIX 800VA 12V Salient features 9 Sine Wave output 9 Built in sealed maintenance free SMF battery 9 Fuzzy logic control a unique amp advanced technology 9 Smart Overload Sense and Short Circuit Protection 9 Optional No Load Shutdown 9 Automatic Low Battery Cutout 9 Smart SMPS based fast battery charger with automatic power factor correction Instant switch over to protect sensitive appliances Battery lasts 50 longer than ordinary battery 9 User friendly Graphical LED Display 9 Future Expandability possible 9 Automatic Load Shut down GLOBAL CERTIFICATIONS ISO 9001 2000 m ISO 14001 2004 Before connecting operating or adjusting this unit please read this instruction booklet carefully Customer Care 91 124 4170561 566 mmm SINE WAVE HOME UPS T d Clones Congratulations for choosing Su Kam Sine Wave Home UPS This Sine Wave Home UPS has been developed using state of the art Micro controller based technology N Su Kom Some of the distinguishing features of the Su Kam SineWave Home UPS 9 Sine Wave output to run all 9 Fuzzy logic control a unique amp the appliances advanced technology 9 Built in sealed maintenance free 9 User Friendly Graphical display SMF battery 9 Smart Overload Sense and Short Circuit Protection 9 Smart S
3. Check if overload short circuit symbol is glowing Reduce load and reset the Home UPS by Power Active switch Also Check the reset fuse or circuit breaker given at the back panel Home UPS does not operate Check the internal battery connections DC Fuse and power active switch position Home UPS trips frequently at back up mode Symptoms Reduce the load and restart the Home UPS through the power active switch Problem Remedy There is no output power Check condition of battery amp recharge Low Battery Loose Check and clean all connections battery connections Check all AC output connections amp reset the AC Fuse Loose AC output connections AC Fuse trip System shut down after 20 sec no display Output of Home UPS is wired back to its own input Check the proper AC input and output wiring Low High AC output voltage Meter must be a true RMS reading meter Measuring with the wrong voltmeter Low surge power Weak battery or Loose internal Battery Connection Check Battery amp all connections ym Shooting 9 23 05 08 SINE WAVE HOME UPS S Su Kam TECHNICAL SPECIFICATIONS MODEL MATRIX CAPACITY 800 12 VOLTAGE LIMITS NARROW WINDOW UPS MODE Mains A C Low Cut 185 10V Mains Low Cut Recovery 190 10V Mains A C High Cut 265 10V Mains A C High Cut Recovery 260 10V VOLTAGE
4. LIMITS WIDE WINDOW W UPS MODE Mains A C Low Cut Recovery 120 10V Mains A C High Cut 285 10V Mains A C High Cut Recovery 275 10V OUTPUT PARAMETER Mains Output Same as Input 45Hz 55Hz Output Frequency 50 0 Hz 0 1 Hz Output Voltage with Full Load 220V 200V x 10V Waveform Sine Wave Overload Above 10096 Short Circuit Protection 225096 Load Few msec BATTERY CHARGING SMPS based charger with Automatic Power Factor Correction Maximum Charging Current Limit 14 2 0 Amp Charging Boost Voltage 13 9V 0 2v Charging Float Volatge 13 6V 0 2V Battery Lower Voltage Limit 10 2V 0 2V Recommended Battery Capacity 135AH 165AH Number of Batteries 4 Topal Note Specifications subject to change without prior notice Specification SE 2222 2 2 2222 10 REV 23 05 08 mmmEEH SINE WAVE HOME UPS N SU MODEL MATRIX CAPACITY 800VA 12V TECHNOLOGY Microcontroller based state of the art technology using MOSFETs Fuzzy Logic Control Technology ENVIRONMENT Storage Temp 0 50 C Kom Operating Temp 0 40 C Humidity 0 90 Non condensing Dimension W X D X H in mm 250X610X460 250X610X460 Weight Kg 66 Kg with 135 Ah battery 74 Kg with 165 Ah battery Technical Jechnica Note Specifications subject to change without prior notice e fii Dpecijication RE
5. 5 E mail jaipur su kam com KOLKATA 8th Floor Room No 14 Shanti Niketan Building 8 Camac Street Kolkata 17 West Bengal Tel 033 32963664 09903114026 Email kolkata su kam com PATNA D 3 Jula Niketan West Boring Canal Road Anand Puri Patna 800001 Bihar Tel 0612 3200776 09934015347 Email patna su kam com NSuKam www su kam com SU KAM POWER SYSTEMS LTD 6th Main MICO Layout BTM II Stage BHUBANESHWAR 389 Bomikhal Cuttack Puri Road Bhubaneshwar 751006 Orissa Tel 0674 2585120 09937014979 CHENNAI Old No 87 amp New No 23 Valluvar Salai Arumbakkam Chennai 600106 Tel 044 32984497 09952966135 09940634442 E mail chennai su kam com DELHI WZ 1401 02 Nangal Raya Near Lajwanti Garden New Delhi 110046 Tel 011 32560709 32533361 09971497598 Email delhiservicecenter su kam com HYDERABAD Plot No 81 Syndicate Bank Colony West Marredpally Secunderabad 500 026 Andhra Pradesh Tel 91 40 27717628 09959778881 E mail hydservice su kam com JAMMU Malik Market Channi Rama Bye Pass Road Jammu 180004 J amp K Tel 91 9906908470 9906905009 E mail jammu su kam com MUMBAI 15 RNA Arcade 1st Floor Cross Lane No 3 Lokhandwala Complex Andheri West Mumbai 400058 Email mumbaiservice su kam com Tel 022 40166900 Fax 022 40166905 PUNE 940 2nd Floor Synagogue Street Near Railway Reservation Centre Camp
6. EN 1 Auto DC Fuse2 X 40A 2 Toggle Switch for Narrow Window UPS Wide Window W UPS mode 3 Toggle Switch for No Load Continue NLC No Load Shut down NLS mode 4 Output Socket 6A 250V AC Universal Type 5 Core Input Wire Mains Input for Home UPS 6 Output Socket 10A 250V AC D Type 7 Resetable Fuse 6 A 250V AC Note 1 Position the Toggle Switch 2 at the back panel to NarrowWindow UPS mode if you want to run PC load otherwise you can place the switch to WideWindow W UPS mode 2 Position the Toggle switch 3 to No Load Shutdown NLS mode optional if you want to switch off the system in case of no load or load 476 Place the switch to No Load Continue NLC mode if you want to run the system in case of no load condition or any other load Back a nel REEL ee r L rui 4 REV 23 05 08 mmm SINE WAVE HOME UPS NSu Kam FOR UNINSTALLING THE BATTERY Step D D Step A Open all screws remove cover a a a UE TE Tai la TAR aj id if M Open tray locks amp remove it aL AT 1 Open screws of support clips for battery tray Tight support clamps downward as shown Step Pull the battery tray slowly so that it will rest on the floor through supporting clamps Open battery amp terminals 7 Open screw
7. MPS based fast battery charger with automatic power factor correction 9 Automatic Load Shut down 9 Peak Power output 3 times 9 Very Fast Switch over time Provides long power back up both for your PC and home appliances 9 Future Expandability possible This manual will help you to better understand your Sine Wave Home UPS increase your convenience in using itand maximize its benefits for you Feel free to contact our authorized dealer or us at info su kam com You can also visit our website www su kam com anytime for any clarification or more information We value your suggestions and comments Su Kam is committed to continual product improvement and the best way to accomplish this task is by listening to our valued customers This commitment gets strengthened every time you buy a Su Kam product We appreciate the support you have shown us through the purchase of our product Please read this manual to become familiar with its features and various applications Regards Su Kam Power Systems Limited pz O REV 23 05 08 N SU SINE WAVE HOME UPS mummmm CONTENT KNOWING YOUR HOME UPS Msc 12 S BACK PANEL e00e00e0eeaae ea eaaa eaaa eaaa eea ana en nane ana eaaa e nn eaaa nana eon nane ea LR a e 3 4 _ UNINSTALLING THE BATTERY 5 8 INSTALLING THE BATTERY 6 8 IMPORTANT SAFETY INSTRUCTIONS e 7 8 SPECIAENOT GES 8 UTROUBIESHOGTBIG
8. Pune 1 Maharashtra Tel 020 32303900 30523788 09975496268 Email pune su kam com FACTORY 64 DIC INDUSTRIAL AREA BADDI DISTT SOLAN H P INDIA CORP OFF 54 SECTOR 37 PH VI DISTT GURGAON HARYANA INDIA REGD OFF WZ 1401 2 NANGAL RAYA NEW DELHI 46 CHANDIGARH SCO 215 217 3 Floor Office No 302 Sector 34 A Chandigarh 160019 Tel 0172 4648509 09878694005 E mail chandigarh su kam com COCHIN Door No 27 77 Plot No 188 8th Cross Road Girinagar Cochin Ernakulam 682020 Kerala Tel 0484 2316141 09995882575 Fax 0484 2316141 E mail cochin su kam com GHAZIABAD 13 7 Site No 3 Meerut Road Industrial Area 3 Near Uttam Toyota Ghaziabad 201001 Uttar Pradesh Tel 91 120 3239910 9810434566 9997797852 E mail ghaziabadservice su kam com INDORE F 47 MIG Colony Near Criestean Eminent School Indore 452001 Madhya Pradesh Tel 0731 3204887 09993590245 E mail indore su kam com KANPUR 403 404 Gopala Chambar 4th Floor Parade Kanpur Tel 09956295691 Email kanpur su kam com NAGPUR R 2 Near 8 Rasta Chowk Laxmi Nagar Nagpur 440022 Tel 0712 3297252 09975496264 Email nagpur su kam com RANCHI 74 D Plot No 1 Park Road 3 Ashok Nagar Ranchi 834002 Jharkhand Tel 0651 3203277 09934015338 Email ranchi su kam com
9. V 23 05 08 11 N SU Kom SINE WAVE HOME UPS and of warra nly SU KAM POWER SYSTEMS LIMITED warranttothe original purchaser provided the product is stillin possession of and used by the original purchaser from the date of purchase The warranty stands on all Electronics Metal parts except LCD switches and external body for Home UPS will be for a period of 24 months amp for batteries 12 months from the date of Manufacturing The warranty will be automatically terminate on the expiry of the warranty period even in caseof theHomeUPS not beinginuseinthe specified period Thiswarrantyisvalidonlyif it is duly signed bytheauthorized dealer The warranty will be invalidated if defects arising in company s opinion by reasons of accident abuse misuse neglect improper installation if notundertaken by the company or its representative fire flood or other act of GOD and any other natural calamities and any other unauthorized repairs done or carried out will have to be borne by the purchaser The problem of fuse blown will not be included in the warranty of the product The services given forthe same will be paid service Thecompany will not be held liable in any condition for any loss or injury or damage caused to life or property or death and disability caused to any form of life for any reason whatsoever Thewarranty will not apply ifthe original seals a
10. for the Home UPS In this case at once reduce the extra load and replace the glass fuse given at back to restore the mains line During this stage the Mains ON graphic symbol glows intermittently with buzzer beeps Lont E A Pinel REV 23 05 08 NSuKam 5 BATT LOW This graphical symbol when glows indicates that the battery voltage has gone down to the lower limit during discharge SINE WAVE HOME UPS IEEE After this indication Home UPS will shut down automatically after few minutes During this the buzzer givesa continuous beep 6 OVERLOAD SHORT CIRCUIT This graphical symbol when glows indicates that either Short circuit has occurred or there is Overload on the Home UPS The Home UPS resets itself automatically and makes 8 attempts in case of overload and 4 attempts in case of short circuit to turn on again if the overload or short circuit continues even after these attempts it turns off permanently and will turn on only after ON OFF power active switch is turned OFF and then turned ON In the event of unsuccessful attempts it automatically shuts down During overload or short circuit graphical symbol lights up and the buzzer gives beep The beep is intermittent in case of overload and short circuit If there is short circuit at the output the Home UPS will turn off permanently after a few attempts It can be reset by removing short circuit and then switching off and on the power active switc
11. h 7 NOLOAD SHUT DOWN INDICATION No load shut down can be activated by positioning the switch given at back panel towards NLS position In this case if load is lt 576 then system will shut down automatically In this condition Inverter ON LED glows continuously and charge LED blinks once in 5 seconds System will reconnect the load after 20 seconds if load gt 576 No load shut down be disabled by positioning the switch towards NLC position REV 23 05 08 N SU Kom mmm SINE WAVE HOME UPS BACK PANEL The Home UPS has two battery wires coming out from the rear side a Fuse Holder two toggle switches an output Socket and an input mains Cable or input terminal block Connect the two battery wires to the terminals of the battery the red colored to the positive terminal and black colored to the negative one three core input cable is used to connect the home UPS to theincoming AC Mains Ensure that incoming phase or line is connected to line Red wire neutral is connected to neutral Black Wire and earth is connected to earth Green Wire After this the output is connected through the output socket at the rear of the Home UPS TTT l REV 23 05 08 N SU Kom SINE WAVE HOME UPS EE REAR VIEW OUTPUT OUTPUT NLS W UPS RESETABLE FUSE MIC E BH T3 P 6 cP 5 le 1 BLACK 1 RED GRE
12. ll shut down until correction is made Note Never disconnect the battery cables while the Home UPS is delivering power or battery charger is operating The Power Active Switch has no effect on the charger it turns off only the power output during backup mode To disconnect the batteries for service a turn off the power switch b disconnectallAC power c disconnectall the battery cables Special Notices e Donotswitch on the heavy load TV Refrigerators Motor Cooler etc when Home UPS is running on battery backup and is in UPS mode This may cause rebooting of your computer e Avoid connecting the stabilizer between utility power and Home UPS The AVR of stabilizer may cause your computer to reboot e Werecommend that you have point to point wiring of the Home UPS e GROUNDING INSTRUCTIONS This Home UPS must be connected to a grounded permanent wiring system Special Vio tices jagi Ni SSS SSS ee a 2 8 8 REV 23 05 08 mmm SINE WAVE HOME UPS Symptoms NSuKam TROUBLE SHOOTING Rectifications Main Power is coming Home UPS shows mains fuse blown Trip on its display panel Reduce the load and reset the fuse or circuit breaker given at the rear side of the Home UPS No Power during backup mode Check if low battery symbol is glowing switch OFF the Home UPS by power active switch Allow the battery to charge before running the Home UPS on battery again
13. ppropriate section of this instruction manual 2 Do not expose Home UPS to rain liquids of any type The Home UPS is designed for interiors only Handle it very carefully while moving Home UPS from one place to another place because it is very heavy 74 Kg and have internal SMF Battery 3 Do not disassemble the Home UPS take it to a Su Kam Engineering Service Centre when service or repair is required Opening by unqualified personnel entails electric shock or fire hazard To reduce risk of electric shock disconnectall wiring before cleaning Provide ventilation to outdoors from the Battery compartment Do notcover your Home UPS with any cover or cloth 00 Ux GE Do notinstall this Home UPS or near flammable materials plywood Chemicals gasoline etc 8 Beextracautious when working with metal tools on and around battery It could short circuit the batteries or other electrical parts producinga spark thatcould causean explosion 9 Remove conductive jewelry such as rings bracelets necklaces and watches when working with a battery A battery can producea short circuit current high enough to welda ring or causing severe burns REV 23 05 08 NSuKam IMPORTANT PRECAUTIONS The output side of the Home UPS AC wiring should never be connected to a SINE WAVE HOME UPS generator or incoming utility power This condition is far worse than a short circuit If the unit survives this condition it wi
14. re found broken or tampered with x Free service under the terms of warranty will be provided only by authorized representatives dealers of the company anywhere in India The company expressly denies the right of any person to incur or assure for it any other liability or obligation in connection with the sale of Home UPS Claims if any to this warranty shall be made only before courts having jurisdiction in New Delhi Please send your query or Complaint to info su kam com WARRANTY CARD Model No Serial No Name of Purchaser Address Date of Purchase Dealer s Name DEALER STAMP n ty 2 REV 23 05 08 PKG ML 104 SU KAM OFFICES ADDRESSES BANGALORE H No 449 Ground Floor 7 th Cross Bangalore 560076 Karnataka Tel 080 32961610 41506332 E mail bangalore su kam com CHATTISGARH Flat No 1 Govind Kunj Civil Line Near Jabal Fabricator Raipur 492001 Chattisgarh Tel 0771 3209092 09981541645 DEHRADUN Vedwalia Ward No 15 Bhusa Store Near Shiv Mandir Sharanpur Road Village amp P O Majra Deharadun 248001 Uttarakhand Tel 09999399605 Email dehradun su kam com VADODARA 203 Padmavati Complex Shrenik Park Char Rasta BPC Road Akota Vadodara 390020 Tel 0265 3206250 09974555280 E mail vadodara su kam com JAIPUR 206 Adarsh Plaza Khasa Kothi Crossing SJS Highway Jaipur Rajasthan Tel 0141 4016625 0987869400
15. s of holding clamps of battery and remove it 8 Pull the battery completely amp lift the battery with the help of lifting straps Battery tray resting on the floor through supporting clamps Battery Ma instal on REV 23 05 08 5 NSu Kam FOR INSTALLING THE BATTERY Open all screws remove top amp side cover if Step D already open than start from next step PURE SINE WAVE HOME UPS Pull the battery tray amp tight support clamps downward as shown Place the battery carefully Battery tray resting on in tray with the help of the floor through supporting clamps lifting straps Place the holding clamps of battery and tight screws 8 Nos from front amp back side of the battery Push the tray slowly so uia that battery goes inside by 7076 6 Tight battery terminals 7 Open the support clamps amp tight again in Upward position as shown 8 Push battery tray carefully 9 Place the tray lock at their position amp tight it 10 Place the cover of the UPS amp tight all screws Battery OO U Snstallation REV 23 05 08 6 mmm SINE WAVE HOME UPS N SU Kom IMPORTANT SAFETY INSTRUCTIONS Before proceeding further kindly go through the safety instructions carefully General Precautions Before using the Home UPS read all instructions and cautionary markings on the Home UPS the Battery all a

Download Pdf Manuals