Home
FiberSource CMY150
Contents
1. Stand alone operation 19 Getting started Selecting 20 4 3 Plug the fixture s or data link s data input cable male into the 3 pin DMX RS 485 OUT socket on the MP 2 Apply power to the fixture and the MP 2 Select Read Memory Card from the MP 2 menu Select the most recent FiberSource CMY150 software from the list Note that these files are numbered according to the firmware level The firmware version that is installed in the FiberSource CMY150 is displayed by its LEDs on power up The number of red flashes in the Power LED indicates the digit to the left of the decimal point and the number of green flashes in the Data LED indicates the digit to the right of the decimal point For example if the firmware version is 1 3 the Power 1 flashes red once and Data LED flashes green three times Select Fixture menu Itis from this point you use the keys on the uploader to navigate and select the desired menu item For further guidance see the following sections fixtures to program Before selecting any fixture to program you must have set its control address If you have not yet done so follow the instructions described in Control address on page 14 You have the option of programing all the FiberSource CMY 150s on a data link or an individual FiberSource CMY 150 Fixture specific settings such as the control address should be made in single fixture mode If no other fixtures are connected however then all
2. interval 1mm fiber D 38mm P N 91611034 Fiber adaptor 75 350 pcs 25 pcs interval O1mm fiber D 30mm P N 91611035 MP 2 uplo d ts ii Ege s NE ete enue ee Be alae NE ts P N 90758420 MC X controller 220 245 V 50MHZ o oooooooooomomom oooo P N 90718200 MC X controller 110 120 V 60 Hz RR P N 90718300 Philips MasterColor CDM SA R 150W 0 00 o eee ee P N 97010113 Osram HOER 150Wz i5 vei v EVER Ga E PARES HORE TESS P N 97010101 ATi Fiber so cco rt ee ete RR TES EAST M etd P N 62400205 Specifications 41
3. Each scene has a dynamic part the fade during which effects move to the scene s programmed positions and a static part the wait where the effects in the scene are expressed The duration of the fade and wait is programmed individually for each scene The fade time may be 0 120 seconds the wait time may be 0 600 seconds The total time it takes a scene to execute is the sum of the fade and wait times Programming is performed using the stand alone Program menu options to program effects such as Dimmer The dimmer level Cyan The color Magenta Yellow Random A continuously changing and random mix of all three or any colors two of the primary subtractive colors CMY The speed of the effect can be set to slow medium or fast Fade The fade time anything from 0 to 120 seconds is the time it takes to change from one color to another If the fade time CARE and wait time are both 0 the colors change continuously Wait This is the duration a color is applied A wait time can be time from 1 second to 600 seconds When operating multiple fixtures in master slave mode the wait time in slave fixtures is disregarded and is determined by the master fixture Each fixture fades at its own rate and then waits for the master to signal a scene or program start before continuing When programming a master fixture keep in mind that its total scene times should be equal to or longer than the fade times of the
4. The connectors are wired pin 1 to shield gnd pin 2 to signal cold and pin 3 to signal hot Use RS 485 data cable designed for outdoor use to extend the link RS 485 cable has low capacitance and a characteristic impedance of 85 to 150 ohms It is electrically shielded and has at least 1 twisted pair of conductors The minimum wire size is 0 2 mm 24 AWG for runs up to 300 meters 1000 ft and 0 322 mm 26 AWG for runs up 500 meters 1640 ft When the fixture is installed outdoors the XLR connectors must be protected in a weatherproof housing Alternatively ground g hot white data cables may be connected in weatherproof electrical bald junction boxes or the data cable can be replaced with not used separate input and output cables that connect directly inside E P E y PCB data the fixture The leads connect to the main circuit board as connections shown in the illustration to the right Installation Adaptors Adaptors may be required to connect the FiberSource CMY 150 to the controller or other 5 pin devices Adaptor cables for indoor use are available from Martin The adaptor cables are wired as shown below 5 pin to 3 pin 3 pin to 5 pin Adaptor Adaptor Male Female Male Female 1 1 1 1 2 2 2 2 3 3 3 3 4 4 5 5 P N 11820005 P N 11820004 SPLITTER AMPLIFIERS A device such as the Martin 4 Channel Opto Isolated RS 485 Splitter Am
5. and then selectGo Stand alone operation SETTING A TIMER TRIGGER Stand alone operation can be set for one or two periods during a 24 hour period using the built in clock If both the clock and the light sensor are used operation starts within the times set or whenever it is darker than the light level setting Operation stops at the stop time provided that the ambient light is brighter than the light trigger setting The first thing to do is to set the correct time See Clock on page 16 You can set timer operation for a single period or for two periods for example one period in the morning and one period in the evening To set the timer for a single period 1 SelectStand alone from the Fixture menu Select Timer Timer then Timer hl Back outto Stand alone Select Timer then Timer1 a A Oo N Select Start then Hour Use the arrow keys to specify the start hour Select OK o Select Minute Use the arrow keys to specify the start minute Select OK 7 Select Back 8 Select Stop then Hour Use the arrow keys to specify the stop hour Select OK 9 Select Stop then Minute Use the arrow keys to specify the stop minute Select OK Programming effects in scenes Stand alone effects can be programmed and stored as scenes Up to 20 scenes can be programmed in each fixture Each scene can contain individual color characteristics light intensity a fade time and a wait time Stand alone operation 23
6. fault protection and a means to isolate the fixture from the mains during service or when not in use Installation The FiberSource CMY150 is equipped with a 1 8 meter 5 9 ft length of 3 conductor 0 75 mm 18 AWG electrical cable for connection to the AC power supply The cable attaches with 1 4 female spade plugs on the live and neutral wires and a ring terminal on the ground wire Other cable can be installed as follows Replacing the mains lead 1 2 3 4 Installing Isolate the fixture from AC power Remove the fixture housing Disconnect the existing mains cable and pull it through the hole in the chassis Pass the new cable through the hole in the chassis and connect the leads The live wire connects to PL3 the neutral wire connects to PL1 and the ground wire connects to the chassis screw terminal Draw up the slack in the AC and data cables and replace the fixture housing a cord cap on the mains lead A cord cap may be installed on the mains lead for testing service and temporary applications Following the cord cap manufacturer s instructions connect the yellow and green wire to ground earth the brown wire to live and the blue wire to neutral Table 3 shows some pin identification schemes consult an electrician if you have any doubts about proper installation Wire EU Wire US Pin Marking Screw US brown black live aa yellow or brass blue white neutral N silver yellow gree
7. other fixtures You will get unpredictable results if for example a scene is programmed in the master to last 10 seconds and in other fixtures to fade for 15 seconds Stand alone operation SCENE MANAGEMENT Once you have specified a mix of effects you can store the scene using the options available under the Program menu Store Save settings in the current scene scene Add Save settings in a new scene at the end of the sequence scene Insert Save settings in a new scene before the current scene which moves up a number Tip Think of the Add and Insert ee commands as Save commands to be used as the last step after programming all effects Delete Remove the current scene from memory Scenes above the scene deleted scene move down a number Next Step to the next scene scene Previous Step to the previous scene scene Clear Remove all scenes from the fixture memory scenes Run Run the scenes in the current program program The only indication of what the current scene is comes from the behavior of the fixture When the program is run scenes execute in a continuous ascending loop If a slaved fixture has Fewer scenes than the master fixture it will run these in a cycle continuously until the master fixture signals that the program should start from the beginning again More scenes than the master fixture then the additional scenes will never run because the program will reset to the first scen
8. synchronously Up to 32 FiberSource CMY150s and Exterior 200s may be connected for synchronized operation triggered by a master fixture Synchronous operation of multiple fixtures requires that they be connected on a data link Execution of a stand alone program may be set to start automatically upon power on or toggled on off with an MC X controller which also provides direct selection of seven scenes When programming for stand alone operation you might find the summary of commands available in MP 2 control menu on page 37 useful as a quick reference PROGRAMMING FIXTURES The programming of scenes and setting up of master slave relationships is performed using an MP 2 Uploader The uploader is connected to the fixture used to program the stand alone settings for that fixture or all the fixtures connected to that fixture by data link and then removed Once a fixture is subsequently switched on it can automatically run the scenes in its program in a loop according to the triggering criteria you have specified time of day or light level To summarize you can use the MP 2 Uploader to program Individual fixtures one at a time The same program in multiple fixtures that are linked with data cables Individual programs in multiple fixtures that are linked with data cables If you are not familiar with the use of the MP 2 then it is recommend that you familiarize yourself with it using the MP 2 Uploader manual
9. 3 fuses The main fuse is located on the small circuit board and the secondary fuses for the low voltage power supplies are located on the main circuit board Fuse replacement requires a 5 mm Allen wrench To replace a fuse Make sure the FiberSource CMY150 is isolated from AC power Remove the fixture housing Locate the main fuse which can be found by following the power cable to the smaller of the two printed circuit boards This is located just to the side of the lamp housing The mains fuse is a T 3 15 amp high 12t 250 volt fuse Replace the defective fuse with one of the same size and rating Replace the fixture housing before applying power Service 33 Problem No response from fixture when power is applied TROUBLESHOOTING Probable cause s No power to fixture Primary fuse blown Remedy Check power cables Replace fuse Secondary fuse blown Replace fuse Fixture resets but does not respond correctly to controller DMX mode operation Controller not connected Incorrect addressing of the fixtures Connect controller Check address setting on fixture and controller Bad data link connection Inspect cables and correct poor connections and or broken cables Conflict between tracking and vector control Eliminate scene cross fade on controller or set ch 7 to 0 Data link not terminated Defective fixture or 2 devices transmitting on link Insert termina
10. FiberSource CMY150 user manual Measurements are in millimeters 2001 2006 Martin Professional A S Denmark All rights reserved No part of this manual may be reproduced in any form or by any means with out permission in writing from Martin Professional A S Denmark Printed in Denmark P N 35000102 Rev E Introduction 0 000 cee ee eee eee eee 4 UN Packing mercede eo ge eges ea ia 4 Safety information ssena 0 00 cece eee 4 Installation oi ii honor A n 6 AG DOWOF2 r4 aua ti toe wart v dete Aaa 6 Fiber optie caderea erea e Eaa e Ra ba eR EE E RR PEN Ur E 9 Fixture orientation and location isses 11 Data link erem vehe xv exeo eee xe tis 12 Settings ost a nisi d da Ra Ce Ra Ru eran Cad d auis 14 MOIES bei NUR PRUGE O Dace RUE ER demo ae 14 Control address ooooccoococcc o 14 Personality settings 0 0 cece e 15 CIOCK s sto O Ree vu 16 General operation llleessereeeeese 17 General guidelines liliis 17 The LEDs and fixture operating StatUS o ooooooococooooooo 17 Stand alone operation ssssus 19 Programming fixtures llis nee 19 Executing stand alone scenes with an MC X Controller 26 Controller operation oooooccncoconn o 27 kamp control La aee bx es geo gee a 27 EITOGIS Sce baeo Song ante coitu e aa date ERAI RA aite Daath le RR e
11. Uploader user manual for details Note Fixtures do not provide feedback to the uploader Therefore the current settings can only be read by observing the behavior of the fixture MODES The uploader provides two ways to access fixtures single fixture mode and all fixtures mode In single fixture mode the uploader communicates only with the fixture at a designated address In all fixtures mode the uploader communicates with all fixtures of the same type to which it is connected Fixture specific settings such as the control address should be made in single fixture mode If no other fixtures are connected however then all fixtures mode may be used Global settings are made easiest in all fixtures mode CONTROL ADDRESS The control address also known as the start channel is the first channel used to receive instructions from the controller Each fixture needs its own control address set and uses this address and subsequent control channels to receive instructions from a controller The FiberSource CMY 150 uses seven channels of control data It reads the data on the start channel and the next six channels If the control address is set to 100 the fixture uses channels 100 101 102 103 104 105 and 106 Channel 107 would be the control address for the next fixture The factory set control address is 1 If two or more fixtures are set up with the same address they will receive the same instructions and should behave identicall
12. When set to off the reset command executes only if channels 3 4 and 5 are set to values from 230 to 232 Automatic Lamp on When the Automatic Lamp on personality is on the fixture turns on the lamp within 90 seconds of power on When set to off the default setting a lamp on command is required to turn on the lamp To set a personality setting Prepare and connect an upload device as described in the uploader user manual Apply power to the fixture Select single fixture mode to change a setting on a single fixture or all fixtures mode to make global changes If using single fixture mode enter the fixture s address Select Special from the fixture menu Select the desired personality and setting See MP 2 control menu on page 37 Press OK Settings 15 16 c N O oO A WO I CLOCK The FiberSource CMY 150 has a battery operated 24 hour clock that can start and stop stand alone operation To set the clock Prepare and connect an upload device as described in the MP2 Uploader manual Apply power to the fixture Select all fixtures mode Select T ime from the fixture menu Select Hour and scroll to the current hour Press OK Select Minute and scroll to the current minute Press OK Press Back to return to the main menu Settings GENERAL OPERATION GENERAL GUIDELINES For optimum lamp life turn off the lamp whenever illumination is not required for extended periods of an hour or more However i
13. a clean lint free cloth wetted with alcohol N Holding the new lamp by its base insert it firmly and squarely into the lamp housing Gently re insert the lamp without winding the wires around the lamp If you are installing the Osram HQI R 150W lamp note that the lamp may not be operated in any position other than horizontal When the lamp is installed in the fixture turn it so that the wires will point towards the ground when the fixture is permanently installed This positions the filament in the ideal horizontal burning position If this is not done the lamp may deteriorate at an accelerated rate 9 Connect the wires on the new lamp to the connecting plug 10 Replace the lamp cover plate re insert and tighten the screws 11 Replace the fixture housing Service CLEANING Wipe off loose dirt with a damp cloth Clean the housing with a soft brush or sponge and a mild non abrasive car washing detergent Cleaning the fan and air filter To maintain adequate cooling dust must be cleaned from the fan and air filter periodically 1 Disconnect the fixture from power 2 Remove the fixture housing using a 2mm Allen wrench 3 To remove the air filter take off the fixture housing and then remove the two screws as shown in the following illustration 4 Remove dust and dirt from the fan blades and air filter using a soft brush cotton Swab vacuum or compressed air 5 Replace the fixture housing The ai
14. bel which can be found on the base of the fixture If your local AC voltage or frequency differ from the settings for your model the fixture s power supply must be rewired by a qualified installer or technician Model No Voltage Frequency 90523000 230 V 50 Hz 90523100 120V 60Hz Table 1 Default Power Supply Settings 6 Installation Rewiring the power supply Always use the setting that most closely matches the local AC mains voltage and frequency 1 Verify that the FiberSource CMY150 is isolated from AC power 2 Remove the fixture housing using a 5mm Allen wrench Transformer Ballast 3 On the transformer move the brown and blue wires those with insulated spade plugs to the transformer taps shown for your mains voltage see Table 2 Important Do not move the grey wire from terminal 9 or the black wire from terminal 15 Mains voltage Setting Brown wire on tap Blue wire on tap 95 109 V 100 V 12 10 110 130 V 120 V 12 9 200 219 V 210 V 15 10 219 239 V 230 V 15 9 240 260 V 250 V 16 9 Table 2 Transformer settings 100 volts 120 volts 9 10 11 12 13 14 15 16 9 10 11 12 13 14 15 16 n O O nagn 8Ll9 GS PECL brown black blue brown black blue grey grey orange 12 V orange 12 V orange 12 V orange 12 V purple 24 V purple 24 V purple 24 V Mayo y DEC purple 24 V Installa
15. cautions listed below and observe all warnings in this manual and on the fixture If you have questions about how to operate the fixture safely please contact your Martin dealer or call the Martin 24 hour service hotline at 45 70 200 201 Guarding against electric shock Disconnect the fixture from AC power before removing or installing the lamp fuses or any part Always ground earth the fixture electrically Use only a source of AC power that complies with local building and electrical codes and has both overload and ground fault protection Refer all service to a Martin service technician Introduction Preventing UV radiation and lamp explosion Never operate the fixture with missing or damaged lenses without a fiber adaptor installed or with the housing removed When replacing the lamp allow the fixture to cool for at least 15 minutes before opening the fixture Do not stare directly into the light Never look at an exposed lamp while it is lit Replace the lamp if it becomes defective or worn out Guarding against burns and fire Never attempt to bypass the thermostatic switch or fuses Always replace defective fuses with ones of the specified type and rating Keep atleast 0 2 meter 8 in clear around the air vent Keep all combustible materials for example fabric wood paper at least 0 1 meter 4 inches away from the fixture Keep flammable materials well away from the fixture Install the fixtur
16. e fan 35 DMX PROTOCOL Start code 0 DMX channel Value Percent Function Reset Lamp On Off 1 0 207 0 81 Reserved no change E 208 217 82 85 Reset fixture If the command is 218 227 85 89 Reserved no change E ecc toMy nels 228 237 89 93 Lamp power on 230 to 232 238 247 93 97 Reserved no change 248 255 97 100 Lamp power off Note T gt 5 seconds 2 Dimmer 0 255 0 100 Closed open 3 Cyan 0 255 0 100 White gt Cyan 4 Magenta 0 255 0 100 White gt Magenta 5 Yellow 0 255 0 100 White gt Yellow Random Color Mixing 0 14 0 5 Off 15 34 5 13 CMY slow 35 54 13 21 CMY medium 55 74 21 29 CMY fast 75 94 29 37 MY slow 6 95 114 37 44 MY medium 115 134 45 52 MY mix fast 135 154 53 60 CM slow 155 174 61 68 CM medium 175 194 68 76 CM fast 195 214 76 84 CY slow 215 234 84 92 CY medium 235 255 92 100 CY fast Speed 0 2 0 1 Tracking 7 3 245 1 96 Fast gt slow 246 251 96 98 Reserved no change 252 255 99 100 Fast 36 DMX protocol MP 2 CONTROL MENU Level 1 Level 2 Level 3 Level 4 Level 5 Effect default settings bold DMX address 1 512 Select control address Off Disable stand alone operation Enable SA On Enable stand alone operation Off Disable light level operation Enable 9 p 5 On Enable light level operation Light level Sets the l
17. e in a well ventilated area Never place filters or other materials over the lens The exterior of the fixture becomes very hot up to 70 C 158 F during normal operation Do not locate the fixture in areas where accidental contact is likely Do not modify the fixture or install other than genuine Martin parts Do not operate the fixture if the ambient temperature Ta exceeds 40 C 104 E Preventing injury due to falls When suspending the fixture above ground level verify that the structure can safely hold the weight of all installed devices Block access below the work area whenever installing or removing the fixture Introduction 5 INSTALLATION This section describes in general terms how to mount the fixture and connect it to data and AC power The procedures in this chapter shall be performed by qualified professionals 1 AC power Fiber optic cable on page 9 Fixture orientation and location on page 11 Rh OO DY Data link on page 12 AC POWER Do not connect the FiberSource CMY 150 to an electrical dimmer system doing so can damage the electronics Warning Disconnect the fixture from AC power before removing any cover Important Verify voltage and frequency settings before applying power POWER SUPPLY SETTINGS The FiberSource CMY 150 is factory wired to one of the configurations shown in Table 1 The model number and factory settings are printed on the serial number la
18. e when the master starts its program from the beginning Automatic program start at power on You can specify that the program should start automatically when the fixture is powered on 1 From the Stand alone menu select Auto prog on 2 Select On Stand alone operation 25 Disconnecting the MP 2 Uploader 26 When all the settings have been made disconnect the data input cable from the MP De Reconnect the output cable to the data link or next fixture if applicable and run through the process described in this section EXECUTING STAND ALONE SCENES WITH AN MC X CONTROLLER Execution of the stand alone program can be toggled on or off with an MC X controller which can also be used to directly select and run of any one of the first seven scenes in the program Connect the MC X controller to the FiberSource CMY150 s data input If multiple FiberSource CMY150s are connected in a data link plug the controller into the first fixture in the link To Trigger scenes 00 06 press the numbered preset buttons on the MC X Have each fixture run its own routine press Auto Stand alone operation CONTROLLER OPERATION Important Dimmer The FiberSource CMY150 may be programmed and operated with any lighting controller that is compatible with the USITT DMX standard This section describes how to operate the fixture with a controller See the DMX protocol starting on page 36 for specific control values and Data link
19. es red once and the Data LED flashes green three times 4 The fixture will reset both LEDs will blink yellow Appearance Power LED Data LED Message Steady green Effects OK Steady green Data OK Steady yellow Steady red Steady yellow Invalid data no data Upload in progress Flash red Memory error or during start up the number of flashes indicates the number to the left of the decimal point in the software version number Flash yellow Flash green Flash yellow During start up the number of flashes indicates the number to the right of the decimal point in the software version number Test reset in progress Off No data detected Flash yellow and red Flash yellow and red Application error perform DMX upload See Firmware updates on page 32 Table 4 LED status messages General operation STAND ALONE OPERATION This chapter describes how to operate the FiberSource CMY150 in stand alone mode where the fixture executes color changes at set intervals and speeds at pre defined periods during the day or when the light level falls below a defined level The term stand alone is used to mean that the FiberSource CMY150 is not connected to a controller but is programmed with a series of up to 20 scenes that play continuously in a loop The term stand alone operation can be applied to a single fixture or to multiple fixtures operating
20. fixtures mode may be used Global settings are made easiest in all fixtures mode For example it might be appropriate to program the time or trigger criteria into all fixtures simultaneously while program scenes might be programmed into fixtures individually Note that it is important that all the fixtures have the same software level set or the results will be unpredictable For more information see Firmware updates on page 32 SELECTING A SINGLE FIXTURE To program a single fixture Select Single address from the Fixture menu Select a start address that corresponds to the fixture that you want to program using the arrows Select OK Stand alone operation SELECTING ALL FIXTURES ON A DATA LINK To program all fixtures on the data link simultaneously select A11 addresses from the Fixture menu Enabling or disabling stand alone mode To Disable stand alone mode select Stand alone then Enable SA and then Off Enable stand alone mode select Stand alone then Enable SA and then On Stand alone mode can be disabled temporarily by Turning the fixture off Connecting a controller and sending control signals Stand alone operation resumes when the fixture has been turned off and then turned back on again provided that the Auto prog on option has been specified for the fixture for more information see Automatic program start at power on on page 25 or when another trigger event occurs light level or t
21. he fixture housing using a 5mm Allen wrench 2 Separate the base plate from the fixture chassis by removing the 4 Hex screws using a 5mm Allen wrench 3 Remove the four plastic feet from the base using a cutting or clipping tool 4 Ensuring that both the mounting hardware and the supporting structure are able to bear the weight of the fixture bolt the base plate to the structure using hardware that will fit through the four 13mm 0 5 in holes Note that if you are attaching the fixture to a vertically aligned structure such as a wall then the plate must be aligned horizontally along its length as in the following illustration Due to the restrictions of some lamps and the potential for water to enter the fixture through the air filter vertically aligned mounting on a vertical surface such as a wall is not recommended 5 Re attach the chassis to the base plate with the four Hex screws and a 5mm Allen wrench 6 Replace the fixture housing Installation 11 200 O U o MIO a LN 70 80 L 152 DATA LINK A data link is required for DMX controller operation and for synchronized stand alone operation of multiple FiberSource CMY150s Cable and junctions 12 The FiberSource CMY150 provides a dual 1 8 meter 5 9 ft 24 AWG cable with locking 3 pin male and female XLR connectors for data connection The male cable is the data input and the female cable is the data output
22. ight trigger level 1 is darkest Level 1 255 255 is brightest When setting light switches on off at current level Capture Go Capture current light level None Disable timer operation Timer Timer 1 Use timer 1 to trigger start stop Timer 2 Use timer 2 to trigger start stop Both Timers Use timers 1 and 2 to trigger start stop Hour Set timer 1 start hour Start Minute Set timer 1 start minute Stand Timer Timer 1 alone Sto Hour Set timer 1 stop hour p Minute Set timer 1 stop minute eiu Hour Set timer 2 start hour Timer 2 Minute Set timer 2 start minute Bio Hour Set timer 2 stop hour p Minute Set timer 2 stop minute Do not start the program at fixture power Auto Prog Off on prog p On On Start program at fixture power on The fixture operates in isolation This is No Master Slave the default Master Master Set the fixture to the master in a chain of Slave multiple fixtures Slave Set the fixture to be a slave in a chain of MP 2 control menu multiple fixtures 37 Level 1 Level 2 Level 3 Level 4 Level 5 Effect default settings bold Dimmer 0 255 Set dimmer level Cyan 0 255 Set cyan level Magenta 0 255 Set magenta level Yellow 0 255 Set yellow level Random off Disable random color CMY slow Random colors slow CMY medium Random colors medium CMY fast Random colors fast Cyan Mag slow Random bl
23. ime trigger Setting master slave options for synchronized stand alone Operation Synchronous stand alone operation of up to 32 FiberSource CMY 150s and Exterior 200s may be achieved by linking them together and using the synchronized stand alone operation function in which one unit only transmits synchronization signals to the others Note that only FiberSource CMY150 and Exterior 200 fixtures are supported for synchronized stand alone operation The master fixture triggers simultaneous program start and scene changes in the other slave fixtures Each fixture stores its own program and the master triggers simultaneous program start and scene changes in a cycle based on its own program Each fixture will run its own program repeatedly changing scene when prompted to by the master fixture or until the master fixture finishes its own program and signals that all fixtures should start from the first scene once again If you are running multiple fixtures simultaneously over a data link then you must set the master slave options for each fixture on the data link Stand alone operation 21 DEFINING A MASTER FIXTURE No more than one fixture may be the master Any fixture on the link however regardless of its position may be the master Fromthe Stand alone menu selectMaster slave Select Master This designates the fixture as the master fixture and causes it to transmit synchronization signals to the slave fixtures when its
24. le in the adaptor ferrule according to the instructions supplied with the adaptor ferrule Insert the adaptor ferrule into the port of the FiberSource CMY150 If your adaptor ferrule is the smaller 30 mm diameter adaptor P N 91611035 then you need to insert it into an adaptor ring to increase the diameter to 38 mm Place the adaptor ring onto the adaptor ferrule so that the ends are flush Screw the adaptor ring fast using a 2mm Allen wrench Do not push the adaptor ferrule past the end of the adaptor ring as the fiber will be too close to the light source and will be damaged Tighten the set screw with a 2 mm 5 64 in Allen wrench Installation FIXTURE ORIENTATION AND LOCATION The FiberSource CMY 150 can be installed in dry or damp locations Do not Bury the FiberSource CMY 150 or otherwise locate it in an unventilated space Mount the FiberSource CMY 150 on a wall in a vertical alignment It may be mounted horizontally see Fastening the FiberSource CMY 150 to a structure on page 11 Install in wet locations Install the fixture in a location where it is at least 0 5 meters 20 inches away from the surface to be illuminated at least 0 1 meter away from any combustible materials and away from accidental public contact The fixture normally rests on the four plastic feet in its base Fastening the FiberSource CMY150 to a structure To fasten the FiberSource CMY 150 to a structure 1 Remove t
25. lor values channel 6 random color mixing must be set to 0 Note that mixing 3 colors results in a loss of light the light is blacked out when all 3 colors are fully applied For maximum brightness mix only 2 colors at a time Random color mixing Random color mixing at slow medium and fast speeds is available on channel 6 The colors can be mixed from any two or all three of the primary subtractive colors Choosing a random mixing of just two of the primary subtractive colors will result in the following types of tones Combination Result Cyan amp magenta Bluish tones Cyan amp yellow Greenish tones Magenta amp yellow Reddish tones These random commands take precedence over values set on the cyan magenta and yellow channels Effect speed 28 The speed at which effects fade that is move from one position to another can be controlled in two ways known as tracking control and vector control You may switch between tracking and vector control but you cannot use both at the same time Tracking control is enabled by setting channel 7 the speed channel to a decimal value from 0 to 2 Fades are then programmed using the controller s cross faders The FiberSource CMY 150 has a digital filter algorithm that averages several updates to ensure smooth movement Vector control provides a way to program fades on controllers without cross faders and may provide smoother fades than tracking control with some co
26. n green ground mm green Table 3 Cord Cap Connections FIBER OPTIC CABLE Fiber optic cable is connected to the FiberSource CMY150 using one of the available fiber adaptor kits P N 91611035 for 75 350 x 1mm fibers This has a diameter of 30mm and is supplied with an adaptor ring that increases the adaptor diameter to 38mm so that it will fit in the port of the FiberSource CMY 150 fixture P N 91611034 for 350 800 x 1mm fibers This has a diameter of 38mm Installation 9 The fiber adaptors are tapered to fit a varying number of fiber optic cables The adaptor often needs to be cut for proper fit and maximum light output Cable types The following guidelines provide a starting point for estimating your needs Light transmission through fiber optic cable depends on its quality and results will vary depending on the type of cable used SIDE EMITTING CABLE With 1 fixture best results are had when the fiber optic cable is 10 m 33 ft or shorter The length may be increased to 15 m 50 ft by looping the cable and illuminating both ends With 2 fixtures one at each end of the cable lengths up to 30 m 100 ft can be achieved END EMITTING CABLE Light output decreases with length keep the cable as short as possible The maximum recommended length is 25 meters Cut the light emitting end of the fibers with a sharp knife for maximum output Installing fiber optic cable Warning 10 4 Install the cab
27. ne Rte era 27 Dou soci a naa a aeS 29 Lamp replacement oooocoocccocnc ete 29 Cleaning gations a oA Santa tees os haha pink God auch ante arcana rm eur 31 Firmware updates 1 0 2 0 0 0 cee eee nee 32 Fuse replacement viii daria tie bee bag bie ADR Ok n 33 Troubleshooting i29 3 x E ER EE RUE Ed ai 34 DMX protocol casara ra RR ER E haa RE c a 36 MP 2 control menu 20 00 37 SPECHICAlIONS isis be ieee ieee a owed be ER 40 INTRODUCTION Warning Thank you for selecting the Martin FiberSource CMY150 The FiberSource CMY 150 is an automated 150 watt color changing luminaire for illuminating fiber optic cables in permanent installations It has a weather resistant IP rating of 44 that enables it to be used in outdoor installations It features seamless CMY color mixing and full range continuous dimming The fixture may be operated with DMX controllers in synchronization with other units with or without a controller and in stand alone mode with programmable start and stop times and or light level activation deactivation UNPACKING The FiberSource CMY150 comes with a user manual and a Philips MasterColor CDM SA R 150W lamp installed SAFETY INFORMATION This product is not for household use This product presents risks of lethal or severe injury due to fire and heat electric shock ultraviolet radiation lamp explosion and falls Read this manual before powering or installing the fixture follow the safety pre
28. ntrollers particularly on very slow fades A vector speed is programmed by setting channel 7 to a decimal value from 3 fastest to 245 slowest The speed setting applies to dimmer and color fades When using vector control the controller cross fade time if available must be 0 Controller operation SERVICE Warning Warning This section describes service procedures that can be performed by the user Refer all service not described here to a qualified Martin technician 1 Disconnect the fixture from power before removing the fixture housing LAMP REPLACEMENT The FiberSource CMY 150 uses one of the following discharge lamps Lamp Efficiency Color Temp Average Life Philips MasterColor CDM SA R 33 Lm W 4200K 6000 hr 150W Osram HQI R 150W 35 Lm W 4200 K 6000 hr can only be operated horizontally Table 5 Lamp specifications Installing any other lamp may damage the fixture Allow the lamp to cool for 15 minutes before removing the lamp cover Lamp replacement requires a 5 mm Allen wrench and a Philips screw driver To replace the lamp Disconnect the fixture from power and allow it to cool 2 Remove the fixture housing Service 29 3 Remove the screws on the cover plate over the lamp and then remove the cover plate AR Gently remove the lamp from its housing al Remove the old lamp from the connecting plug o Clean the glass bulb and reflector of the new lamp with an alcohol wipe or
29. on page 12 for connection requirements LAMP CONTROL Avoid striking several lamps at once The lamp can be turned on and off from the controller using the lamp on and lamp off commands on channel 1 If the DMX Lamp off personality is off the lamp off command on channel 1 executes only if each of the CMY channels 3 4 and 5 is set to a DMX value from 230 to 232 Strike lamps one at a time at 5 second intervals Striking many lamps at once may cause a voltage drop large enough to prevent lamps from striking damage electronics and trip circuit breakers To have the lamp strike automatically at power up set the Automatic Lamp on personality to on see page 15 Note After being turned off the lamp must cool for approximately 8 minutes before it can be turned back on EFFECTS The mechanical effects reset to their home positions when the fixture is powered on Effects can also be reset from the controller on channel 1 If the DMX Reset personality is off the reset command on channel 1 executes only if each of the CMY channels is set to a DMX value from 230 to 232 The mechanical dimmer provides smooth high resolution full range dimming on channel 2 Controller operation 27 CMY subtractive color mixing The CMY color mixing system is based on cyan magenta and yellow color filters A continuous range of colors may be achieved by varying the amount of each filter from 0 to 100 on channels 3 4 and 5 To execute specific co
30. ote e ERE E pO pha ML A 150 W discharge Approved models Philips MasterColor CDM SA R 150W and Osram HQI R 150W Gontrol as Remote switchable INSTALLATION Minimum distance to combustible materials 0o oooooooooooo 0 1 m 4 in Mounting points e055 ced eck cee BEG UR Oa ee hele aed 5 x 13 mm 0 5 in holes Minimum clearance around fan and air vents 0 0000 eee eee eee 0 2 m 8 in ENVIO MENE 22 04 ig da na lied Gale Hosen aa ad anit Dry or damp location Orienta cu noob hare ehh keh nd edd aid ida Horizontal CONSTRUCTION HOUSE sted wih v heel ee tee Flame retardant ABS plastic COLOR IE RAL 7016 antrazit gray Tigress protection factor seer ani hth a He OEE IP 44 120V 60Hz US model o oooooocccccccoo UL 1598 CSA C22 2 No 250 0 00 230V 50 Hz EU model 0 0 0 EN 60598 1 EN 60598 2 17 THERMAL Maximum ambient temperature Ta 000 cece eee eee eee 40 C 104 F Maximum surface temperature steady state Ta 40 C 2 020 70 C 158 F Cola da AE TIT ele Pi Filtered forced air cooling system AC SUPPLY ACTMPUE dd o ANE Tee DET E AE os 1 8 m trailing cable w o cord cap Power supply options ooooooocccocccccc 100 120 210 230 250 V 50 60 Hz Primary userre nud at uS X UE 3 15 A high Pt 250 V Specifications MAXIMUM POWER AND CURRENT NOONE esa ett ae asses aloes a tration pay eterna oi 220 W 2 4 A RON ts Haw re E cid es 220 W 2A 208 V Era ee
31. plifier may be used to branch the data link and or extend its length Do not use a Y connector to split the link TERMINATORS Termination of the data link is required for trouble free communication For temporary installations this can be achieved with a male termination plug inserted into the data output cable of the last fixture in each chain A termination plug is simply an XLR connector with a 120 ohm resistor soldered across pins 2 and 3 For permanent terminations the link can be terminated with a 120 ohm resistor across the hot and cold data terminals at the main circuit board inside the last fixture in each chain Building a data link To build a data link Connect a data cable to the controllers data output A male 5 pin to female 3 pin adaptor may be required Lead the data cable from the controller to the first fixture and plug it into the male data cable Connect the output of the fixture closest to the controller to the input of the next fixture Continue in this manner Up to 32 fixtures may be connected output to input Terminate the link as described previously at the output of the last fixture in the chain Installation 13 SETTINGS 14 This section describes how to set the control address personalities and clock To set user options you need a Martin MP 2 Uploader that has been loaded with the FiberSource CMY150 s control software and connected to the fixture or data link Please refer to the MP 2
32. program runs DEFINING SLAVE FIXTURES All other fixtures must be set as slave fixtures From the Stand alone menu selectMaster slave Select Slave This designates the fixture as a slave fixture which will respond to synchronization signals received from the master fixture Automatically triggering stand alone operation 22 Stand alone operation can be set for one or two periods during a 24 hour period and or for a light level SETTING A LIGHT LEVEL TRIGGER Stand alone operation can be set for a light level using the built in light sensor If the light levels fall below the specified level then operation starts If both the timer and the light level trigger are used operation starts whenever it is darker than the light level setting or within the times set To avoid false triggering by sudden light changes for example from automobile headlights the light level must remain above or below the trigger threshold for 5 minutes To set the light trigger From the Stand alone menu select Light level thenEnabl e and then On Select Level and use the arrow keys to select a trigger level from O darkest to 255 brightest The light toggles on and off as you scroll past the current light level Select OK Alternatively you could capture the current light level using the sensor in the fixture and use this as the trigger level From the Stand alone menu select Light level thenEnabl e and then On Select Capture
33. r filter is glued to its support so washing it is not advised We recommend the installation of a new air filter P N 62400205 when the lamp is replaced Service 31 FIRMWARE UPDATES Firmware updates are released when features are added The latest version is available from the Support Area of the Martin Professional web site at http www martin dk The installed firmware version number is displayed by the LEDs on power up see The LEDs and fixture operating status on page 17 Firmware is installed using a Martin uploader or a 4064 DMX interface for the Martin LightJockey controller The procedure is found in the MP 2 user manual and the Martin Software Uploader online help file REQUIREMENTS The following are required in order to install software The FiberSource CMY 150 update file available for download from the User Support Area of the Martin web site http www martin dk The Martin Software Uploader program version 4 0 or later available for download from the Support Area of the Martin web site A Martin MP 2 Uploader connected to a Windows 95 98 ME 2000 PC or a LightJockey Controller with a DMX Interface card Updating fixture firmware with the MP 2 Uploader 32 4 Connect a prepared MP 2 Uploader to the DMX link Apply power to the fixtures and the MP 2 Wait a few moments for the fixtures to reset Select Read Memory Card from the MP 2 main menu Use the buttons on the right to scroll through the ca
34. rd slots Select the slot that holds the desired version of EXT 2 0 O firmware Select Update Software Select Yes to confirm Select Update in DMX mode to start the upload The MP 2 initializes all connected FiberSource CMY150s which respond with two yellow LEDs in the status display Avoid interrupting the process this will corrupt the software After a successful upload the fixtures reset with the new software If an error occurs and the fixtures do not reset data was interrupted or corrupted during transmission Perform a boot mode upload as described below BOOT SECTOR UPLOAD If the normal upload procedure does not work or if the software update notes call for a boot sector update see the following section Performing a boot sector update Service Performing a boot sector update 1 Warning Make sure the FiberSource CMY150 is isolated from AC power Remove the fixture housing Using the diagram on the inside of the fixture housing as a reference locate the jumper on the printed circuit board at position PL2 Move the jumper to the BOOT position across pins 1 and 2 Perform a boot mode upload as described in the uploader manual When the upload is complete disconnect the fixture from power and move the jumper at PL2 back to the LOCK position pins 2 and 3 Replace the fixture housing FUSE REPLACEMENT Never replace fuses with ones of a different rating The FiberSource CMY 150 has
35. se vip em e aote e E PD aO HER Me RIE qr wre RES 200 W 1 1 A 230 Voger Nsure eI Bs Bie aes OOS Be e Me PRTG a eoo ala 210W 1A DIM A O NR 220 W 1A ELECTROMECHANICAL EFFECTS Cyan ll A ada 0 100 Magent filter uos eise EN O 0 10096 Xellow filteg s 45355 cess and ave em SORA RT REY C eMe e Ens 0 100 DIM eI UPLCSOSRTeA UPPRAJ ep ORA UU E SU EM PPAEEANS 0 100 Control options DMX 512 Martin remote control stand alone master slave RECEIVED A s ea s cette sida too auch dA Ue enne Fe Ek ste RS 485 Setting and addressing 2 0 0 cece eese Remote with uploader Firmware updates hats oo 14 oe ee oe GMS eus Serial upload MUF Stand alone trigger options Internal real time clock with timer and light level sensor Stand alone memory e ennnen ri A E hs 20 scenes Data Input pee otitis dame onm nus 1 8 m trailing cable with 3 pin XLR male Data output 0 2 0 0 2 eee eee 1 8 m trailing cable with 3 pin XLR female Data pinout cii eee EA Pin 1 shield pin 2 cold pin 3 hot DMX channel sis s tt See Sige ig keer d E AE CHE RE ia ae 7 ORDERING INFORMATION FiberSource CMY 150 230V 50Hz 0 0 0 ccc cee nee P N 90523000 FiberSource CMY 150 120V 60Hz o ooooooooooooooom oo P N 90523100 INCLUDED ITEMS Userananual coca coria er ideas ati PESE P N 35000102 Philips MasterColor CDM SA R 150W 0 2 0 0 eee ee P N 97010113 ACCESSORIES Fiber adaptor 350 800 pcs 50 pcs
36. t is a good idea to keep the fixture power on so that the fans continually operate regardless of whether or not the lamp is lit This keeps air circulating internally and prevents condensation from building up inside the fixture When the temperature is expected to fall below freezing leave the fixture powered on when not in use to keep the electronics warm The lamp however may be switched off Always allow the lamp to warm up fully before turning it off Avoid turning on several lamps at once THE LEDS AND FIXTURE OPERATING STATUS Two LEDs on the rear panel display the fixture status Normal operation is indicated by two green LEDs See Table 4 for other status messages The LEDs flash off for a brief instant at regular intervals to prevent false readings when the light sensor samples the light level General operation 17 18 When the fixture is powered up 1 Acheck is performed on the software both LEDs will blink yellow 2 If the test is Successful both LEDs will blink green Unsuccessful the LEDs will blink yellow and red In this case perform a DMX upload and restart the fixture 3 The installed firmware version number is then displayed The number of red flashes in the Power LED indicates the digit to the left of the decimal point and the number of green flashes in the Data LED indicates the digit to the right of the decimal point For example if the firmware version is 1 3 The Power LED flash
37. tion l Dimer pen ove dimmer to open position Adjust Closed Move dimmer to closed position Gyan Open Move cyan flag to open position Closed Move cyan flag to full position Open Move magenta flag to open position Magenta p x g g p Re M Closed Move magenta flag to full position Yellow Open Move magenta flag to open position Closed Move magenta flag to full position Require confirmation of lamp off Du lamp Off default On Enable lamp off without confirmation Off Require confirmation of reset command Special DMX reset On Enable reset without confirmation default Off Strike lamp from controller default Auto lamp vus on Strike lamp automatically within 90 On seconds of power on The installed firmware version number is displayed by the LEDs on the top of the fixture The number of red flashes in the Power LED indicates the digit to the left of the decimal point and the number Version Leave of green flashes in the Data LED MP 2 control menu indicates the digit to the right of the decimal point For example if the firmware version is 1 3 the Power LED flashes red once and the Data LED flashes green three times 39 SPECIFICATIONS 40 PHYSICAL Length see caps wie ana anie E a EEG ul Ese pue a 398 mm 15 7 in Mid ae nada lero Solis tasted o 195 mm 7 7 in Helghtzz vos tan VAN Up YU Pa e qs 192 mm 7 6 in Weight ista ted mede PE He asa t rer Vp EU Y PEARS 8 kg 17 6 Ibs SOURCE Lamp 4e hb b
38. tion 7 210 volts WW 230 v olts 9 10 11 12 13 14 15 16 9 10 11 12 13 14 15 16 brown black blue grey orange 12 V orange 12 V l magm 849 G peat purple 24 V purple 24 V Warning 829 S e cl 250 volts 9 10 11 12 13 14 15 16 O 8 965pvgezl ooo O NL brown black blue grey orange 12 V orange 12 V purple 24 V purple 24 V TET brown black blue grey orange 12 V orange 12 V purple 24 V purple 24 V 4 To set the frequency move the brown wire on the ballast to the 230 50 50 Hz or 230 60 60 Hz terminal as shown The wire is released and locked by inserting a small screwdriver in the square hole next to the terminal and prying back the spring 5 Tug lightly on the brown wire to make sure that it is connected securely brown grey 50 Hz MAINS CONNECTION 60 Replace the fixture housing before applying power Hz brown grey For protection from dangerous electric shock the fixture must be grounded earthed The AC mains supply shall be fitted with a fuse or circuit breaker ground
39. tion plug in output of last fixture Bypass fixtures one at a time until normal operation is regained unplug both connectors and connect them directly together Colors cannot be mixed Fixture does not reset correctly Random color mixing is on Electronic or mechanical failure Turn off random color mixing Contact service technician No light lamp cuts out intermittently or burns out too quickly Lamp missing or blown Disconnect fixture and replace lamp Fixture or lamp is too hot Allow fixture to cool If problem persists contact service technician Incorrect power supply setting Check setting Poor or uneven light Adaptor installed incorrectly Refer to Fiber Adaptor Installation Note Rough fiber ends File fiber ends smooth as described in Fiber Adaptor Installation Note Osram lamp filament oriented incorrectly Turn lamp so wires point toward the ground No light and the fan does not run No power to the fixture Check connections Blown fuse Troubleshooting Replace fuse Problem Probable cause s Remedy Lamp too hot to strike Wait a few minutes Lamp will strike when cool Incorrect voltage setting Fan runs but there is no light Burned out lamp Check and correct voltage setting Install new lamp Fixture overheating Troubleshooting Allow to cool Improve air flow Clean th
40. uish colors slow Cyan Mag medi Random bluish colors medium led Cyan Mag fast Random bluish colors fast Mag Yel slow Random reddish colors slow Mag Yel medi Random reddish colors medium Mag Yel fast Random reddish colors fast Cyan Yel slow Random greenish colors slow Cyan Yel medi Random greenish colors medium Cyan Yel fast Random greenish colors fast Stand Program Set scene fade time to zero so that alone Snap Scene changes are immediate Fade time 1 sec 2 min Set scene fade time from one second up to two minutes Mil trig 0s 10m Set scene wait time up to 10 minutes Add scene Go Save new scene to end of sequence Next scene Go Call the next scene Previous i Econo Go Call the previous scene Store scone Go Save changes to current scene Insert scene Go Save new scene before current scene Delete Scene Go Delete the current scene Cir all No Cancel command scenes Yes Delete all scenes Run program Leave Run the scenes in the program Time Hour 0 23 Set the current hour in 24 hour time Minute 0 59 Set the current minute 38 MP 2 control menu Level 1 Level 2 Level 3 Level 4 Level 5 Effect default settings bold Reset On Reset effects to home position Lamp on On Turn on lamp Lamp off Off Turn off lamp Open M Il eff ition All effects p ove all effects to open position Closed Move all effects to closed position O M 3 i
41. y Setting up identical fixtures with the same address is a good tool for troubleshooting unexpected behavior and an easy way to achieve synchronized action Settings Important When setting the address either use single fixture mode or isolate all other fixtures from the uploader To set the control address Prepare an upload device as described in the uploader user manual If you know the address to which the fixture is currently set that is the address to change from connect the uploader to the data link and use single fixture mode Otherwise use all fixtures mode and isolate all other fixtures from the uploader Apply power to the fixture If using single fixture mode scroll to the fixture s current from address and press OK Select DMX address from the fixture menu Scroll to the desired control address and press OK Press OK again to confirm and save the setting PERSONALITY SETTINGS The following settings are available to modify fixture behavior DMX Lamp off When the DMX Lamp off personality is on the default setting lamp power can be turned off from the controller by setting channel 1 to a decimal value from 248 to 255 When set to off the lamp off command executes only if channels 3 4 and 5 are set to values from 230 to 232 DMX reset When the DMX Reset personality is on the default setting the fixture can be reset from the controller by setting channel 1 to a decimal value from 208 to 217
Download Pdf Manuals
Related Search
Related Contents
3200NXT Service Manuals Manual de instrucciones Braun 4725 User's Manual AISIBEAM User`s Manual (Version 3.0) 全旋回式ゴムクローラキャリア User manual ALFA(NET) 71 RTDN Rail ™ Soneco SCS User Guide Copyright © All rights reserved.
Failed to retrieve file