1. growth allowing normal ventilation e Always unplug system before performing any maintenance or troubleshooting e Always unplug system and refer servicing to a qualified electrician when cord is damaged or frayed compressor power control compressor fan or other electrical components are producing unusual noises or odors e Always use parts that are supplied or approved by Airmax Ecosystems Inc Use of other parts may result in poor performance and could create a hazardous situation Local environmental conditions may require more frequent maintenance FR Cooling Fan Check regularly to make sure cooling fan is operating Hot air should be pulled from cabinet not cool air blowing in Air Filter Clean Replace every 3 6 months Replacement filter elements also available Pressure Gauge Mark pressure gauge upon initial start up Check regularly to verify pressure has not significantly risen above or dropped below initial reading Normal operation will range between 5 10 psi Pressure Relief Valve Check regularly to make sure air is not escaping from valve If unit is shut off pressure will need to be released from the system in order for compressor to restart 4 System Installation For quick easy and professional installations it is suggested that the following materials be on site None of the following are included with the Airmax Aeration System e Placement Rope e Utility razor knife e evel e Boat
2. 3 8 Connect Kit 3 8 to 5 8 Connect Kit 5 8 Connect Kit 490204 490205 490206 systems include enough connector kits for 1 Roll 2 Rolls on AM80 amp AM100 of weighted airline plus 1 Roll of direct burial airline per diffuser plate Additional connector kits may be necessary for your installation 1 Membrane Sticks 510165 have the synergy of air stones and are maintenance free 2 Diffuser base is self weighted to support the diffuser in muck 3 Mounting zip straps secure manifold membrane sticks to diffuser base amp 4 Check Valve protects compressor from back pressure A ProAir 4 Diffuser Plate 510164 2 Safety A A e Read all operating instructions carefully e To reduce the risk of electric shock connect only to a properly grounded grounding type receptacle If in doubt have the outlet checked by a qualified electrician e This unit is to be used in a circuit protected by a ground fault circuit interrupter GFCI e Disconnect unit from power source before handling or maintenance e Repair or exchange of cable power cord must be carried through by the supplier manufacturer 4 e This unit has not been investigated for use in swimming pool areas CAUTION e Never connect to an extension cord This may result in equioment failure e Do not allow anything to rest on the power cord e Do not place the cabinet where people may step on the power cord e Never over
3. ATE WWW AIRMAXECO COM Date unit was purchased Example June 1 2011 THANK YOU FOR CHOOSING ond by Airmax OSic Natural Clear Water SFAC7 Airmax Ecosystems Inc er Www airmaxeco com GUARANTEED Guaranteed 866 4 AIRMAX mss 040_11
4. Compressor 6 Pressure Gauge 490244 Helps Monitor 13 6 Grounded Power Cord system Performance AM30 AM60 AM70 AM80 AM100 600209 600213 e Three n i Diffusers 600222 600225 One ProAir 4 Diffuser e Two ProAir 4 Diffusers es ae amp Compressor e Four ProAir 4 Diffusers e Six ProAir 4 Diffusers e 100 3 8 Self Weighted Airline e 200 3 8 Self Weighted Airline e003 9 j e SilentAir Cabinet amp Compressor SilentAir Cabinet amp Compressor e SilentAir Cabinet amp Compressor SilentAir Cabinet amp Compressor PATON eT e Airline Sold Separately e Airline Sold Separately e 300 3 8 Self Weighted Airline e Connector Kits e Connector Kits 600218 e Connector Kits e Connector Kits e 600 3 8 Self Weighted Airline TM SilentAir CABINET amp COMPRESSOR EasySet AIRLINE e Self Weighted Airline 3 8 100 Roll 510118 5 8 100 Roll 510119 Lead free weighted airline is made of durable PVC composite Fish hook resistant and kink free Use from pond s edge to diffuser e Direct Burial Airline Sold separately 5 8 100 Roll 510120 Flexible yet kink free Bury from cabinet and compressor to pond s edge when placing the cabinet and compressor away from the pond 5 8 Direct Burial 5 8 Self Weighted 510120 3 8 Self Weighted 510119 510118 CONNECTOR KITS ProAir 4 DIFFUSER PLATE ISo o ele
5. Natural Clear Water Guaranteed OWNER S MANUAL FOR AM30 AM60 AM70 AM80 amp AM100 Aeration Systems CONTENTS SECTION System Components Safety Seasonal Operation System Installation Maintenance Troubleshooting Warranty NOOR OND THANK YOU FOR CHOOSING 1 System Components The Airmax Aeration System You have purchased the most efficient and cost effective aeration system available on the market today SilentAir Compact Composite Cabinet SilentAir Large Composite Cabinet For AM30 AM60 amp AM70 For AM80 amp AM100 1 Air Flow Regulator amp Brass Ball Valves Adjust Flow to Individual 7 Integrated Cooling Fan 510302 to Extend Life Diffusers AM60 AM100 Systems Only of Compressor 2 High Efficiency Compressor AM30 510100 8 Cabinet High Density Air Intake Pre Filter 510395 AM60 AM100 510103 AM30 AM70 Systems Only AM30 Maintenance Kit 510108 9 Ventilation Louvers 510364 AM60 AM100 Maintenance Kit 510111 AM80 amp AM100 Systems Only Airflow assembly not included with replacement compressor 10 Composite Rock Like Cabinet 3 Rubber Mounted Compressor Ensures Quietest Operation 11 Elevated Cabinet Base Allows for Easy Installation 4 Removable Top for Easy Access to Components No Base Required 5 Pressure Relief Vale 490239 Safeguards from 12 Heat Resistant 3 8 Flex tube 490194 Protects Against Back Pressure High Temperatures of the
6. Raft Swimsuit e Coast Guard approved life jacket e Small stone or gravel e Shovel e Rake e Flathead screwdriver e Sharpie Marker Location e Locate cabinet on a solid support with adequate strength for weight of unit e ocate cabinet away from irrigation sprinklers e Wear a Coast Guard approved life jacket follow all safety and caution guidelines Option 1 When power source is available at pond s edge simply connect one end of EasySet Airline to flex hose and other end to diffuser plate Steps 2 amp 3 are not necessary using this option Option 2 When power source is not available at pond s edge place SilentAir Cabinet next to nearest power source Trench Direct Burial Airline sold separately 1 2 standard irrigation pipe may be substituted from flex tube to pond s edge then connect to EasySet Airline and run to diffuser plate Each diffuser will be a separate run of airline Each run may not exceed 1 000 per airline without performance loss 6 Easy Steps Res NT tae Ed E ey 1 Decide on a location for the cabinet and prep ground May be placed several hundred feet from shoreline using direct burial airline if power is not available at shore 2 Option 2 Only Excavate trench to a minimum of 8 of depth for direct burial line Place and backfill all direct burial airline one line per diffuser i TE aini it r t E l a T i 3 Option 2 Only Connect direct bur
7. cal dealer for electrical troubleshooting assistance Option 1 Check compressor capacitor wir ing for frays or poor connections Wiring loosened or was damaged during shipment or maintenance Option 2 No capacitor wiring issues can be seen Cabinet fan is running Bad capacitor Option 3 Capacitor has been replaced IF COMPRESSOR IS OPERATING ISSUE CHECK Compressor is bad LIKELY CAUSE Contact Airmax or local dealer for repair replacement CORRECTION Option 1 No air leaks are audible in cabinet Compressor running louder and possible excessive vibration Compressor air filter is dirty clogged Clean or replace filter NEVER re install wet filter No bubbles at any diffusers Option 2 Compressor operating normally or making unusual noises Exhibits reduced pressure and or air flow Compressor needs piston maintenance kit and possibly new air filter Contact Airmax or local dealer with specifications for maintenance kit Clean or replace filter NEVER re install wet filter Option 1 Check for leaks at all connections in line and in cabinet If none are audible carefully soray SMALL amount of soapy water onto con nections and look for bubbles Vibration loosened connection or cracked fitting Tighten loose connection or replace cracked fitting as necessary SERED a mee as Option 2 Are all flow control valves in compressor wide open Impro
8. eplaced Option 1 Check for low voltage while Compressor shakes erratically and is making compressor is running Gauge of supply wires to circuit possibly undersized or cabinet is plugged into extension cord If gauge of circuit wiring Is incorrect have electrician replace NEVER use extension cord to operate system for continual use loud noises Option 2 Check for clogged air filter Air filter in need of replacement Clean or replace filter NEVER re install wet filter 7 Warranty Airmax Ecosystems will repair or replace defective parts for a period of 2 years from the date of purchase This excludes normal wear and tear items such as air filters and piston maintenance A copy of your receipt will be required for any system submitted for war ranty Customer will be responsible for return shipping of product Warranty will be void if inspection of unit determines failure due to the following incorrect voltage faulty installa tion including damaged or cut power cords damage from shipping due to poor packaging moisture damage or customer negligence There is a metallic sticker on the side of the compressor and the electrical box similar to what you see on the right For your records copy the appropriate number below Have this information ready when making inquiries regarding your Airmax Aeration System WARRANTY VOID IF REMOVED AM HHH HHA AIRMAX ECOSYSTEMS INC PURCHASE D
9. ial airline to EasySet self weighted airline 4 Connect diffuser to airline Extend EasySet self weighted airline to proper location Place diffuser To ensure proper placement use nylon rope Plates should be located at average depth of pond maxi mum depth following Diffuser Placement Guide 6 Bubbles should be noticeable from all diffuser locations When more than one diffuser is installed adjust valves for maximum performance Once adjustments are made wait several minutes to see results at the diffuser location s Deeper placement of plate s and longer runs of tube will require more flow 9 Connect airline to flex lines supplied with cabinet Open cabinet plug compressor and cooling fan into power control Plug power control cord into power outlet Membrane Sticks Purge every 12 months See below for purging instructions based on model AM30 While compressor is running pull the pressure relief valve and let go Repeat 6 8 times AM60 AM100 While compressor is running shut off all air flow valves except one forcing all air to one diffuser plate for 10 seconds Repeat for each plate 6 Troubleshooting IF COMPRESSOR IS NOT OPERATING ISSUE CHECK LIKELY CAUSE CORRECTION Option 1 GFCI circuit trioped Damage to electrical cord or low voltage from power supply Cabinet fan is not running Option 2 GFCI circuit not tripped GFCI malfunction Contact Airmax or lo
10. mmer months and for optimum aeration benefits Airmax Aeration Systems should run continuously throughout the summer To enhance pond health reduce mucky bottoms and enhance pond s aesthetic appeal try other Pond Logic products MA MuckAway E PondClear fBijNature s Blue E Black DyeMond E Twilight Blue Winter Operation Owner assumes all responsibility for operating Airmax Aeration System during winter months Operat ing in freezing conditions on an ice covered pond will cause large open water areas at diffuser sites Ice thickness around open areas will be much thinner than the surrounding areas Airmax strongly recommends that Danger Thin Ice be posted at frequent intervals around pond Diffuser plates should be moved out of the deepest points of pond to allow a safe zone for fish dormancy and to avoid super cooling effect If you choose to turn your system off for the winter do the following e Unplug system Move cabinet and compressor inside to keep dry e Cover flex tube ends as well as airline ends to prevent debris from entering airline e When turning system back on in spring airlines may contain ice e Use 1 cup denatured alcohol in the airline running out to each plate turn on compressor to push through line and free any ice blockage e Follow initial startup procedure to avoid shock in the pond DIFFUSER PLACEMENT GUIDE AM30 AM60 AM70 AM80 a wm 5 Maintenance
11. per balancing of diffusers Adjust air flow valves on manifold in cabinet until all diffusers operate properly See Section 4 System Installation for more information Option 3 Valves in cabinet are properly balanced and no leaks are evident Compressor beginning to lose compression and needs piston maintenance kit Contact Airmax or local dealer with compressor specifications for maintenance kit Large rolling bubbles instead of fine bubbles at surface above one or more diffuser plates Inspect each diffuser plate for malfunction Diffuser membrane damaged diffuser plate fitting broken or diffuser plate is flipped over Contact Airmax or local dealer for repair replacement Option 1 High pressure reading on gauge Inspect diffuser plates and tubing Air coming out of pressure relief valve for clogging Diffuser maintenance needed Remove any overgrowth around diffuser membrane surface See Sec tion 5 Maintenance for more information Option 2 Low pressure reading on gauge Diffuser plates not clogged Bad pressure relief valve Contact Airmax or local dealer for repair replacement Compressor stops working for periods of tai Hien ESN Inspect cooling fan for proper function Compressor over heating due to bad cooling fan Contact Airmax or local dealer for fan replacement If possible leave top of cabinet open for cooling Otherwise unplug system until fan is r
12. ride or cheat electrical or mechanical interlock devices e Never attempt any maintenance function that is not specified in the user manual e Never operate the system if unusual noises or odors are detected Disconnect the power cord from the outlet and call for service 3 Seasonal Operation So Airmax Aeration Systems are designed for low maintenance and require minimal scheduled maintenance Cabinet inlets and outlets should be kept free of debris and weed The circulation of poor quality low oxygen deep water to the pond s surface can introduce harmful gases and by products into the previously healthy upper regions of the water column These by prod ucts can make the upper regions unfit for aquatic life and could result in fish kill To Prevent Initial Fish Kill Follow this procedure anytime system has been shut off for an extended period of time Day 1 Run system for 30 minutes turn system off for remainder of day Day 2 Run system for 1 hour turn system off for remainder of day Day 3 Run system for 2 hours turn system off for remainder of day Day 4 Run system for 4 hours turn system off for remainder of day Day 5 Run system for 8 hours turn system off for remainder of day Day 6 Run system for 16 hours turn system off for remainder of day Day 7 Begin running system 24 hours day 7 days week f Summer Operation To reduce the risk of fish kills in hot su