User Manual Motion Detector Infra Garde 360AP

image

Contents

1. User Manual Motion Detector Infra Garde 360AP Warning Any work on the main power supply must only be completed by trained specialists The product must be installed in accordance with installation guideli nes standards specific to your country Disconnect the 230V power supply before starting the installation process As aprecautionary measure the power supply of the light should always be fitted with a 250VAC 10A type C fuse in accordance with EN60898 1 Faulty lamps may cause a short circuit and thereby permanently damage the device Disconnect power prior to replacing a lamp To ensure the operational reliability of the detector keep a minimal distance of 1m to lamps installed on the same height level Lamps installed underneath the detector or in the detection area may disturb the functionality Keep the detector away from heating devices In case of malfunction such as continuous lighting or false triggering please refer to the troubleshooting section on this page Function The detector reacts to the motion of heat positive or negative in relation to the environment If a person approaches the monitored area the device will turn on the connected light automatically If the person leaves the area the light will be switched off after the preset duration short impulse 10 sec to 20 min The connected light will be turned on only when the ambient light value is below the adjusted value Installa
2. during daytime
3. econds Lights permanently on continuous light interrupt mains power within 2 seconds Press button for at least 4 seconds to switch from continuous light mode back to automatic operation Check LED The green LED flickers while the detector registers movements Connecting electrical loads High inrush currents will considerably shorten the lifetime of the detector s in built relay Please verify the technical data provided by the lamp or luminaires manufacturer concerning inrush currents specifically with compact fluorescent fluorescent lamps electronic ballast etc in order not to overload the internal relay We recommend connecting a maximum of three to four motion detectors in parallel Loads such as electronic ballast e g for fluorescent lamps and compact fluorescent lamps should be switched via external conductor direct switching is not recommended Technical Data Nominal power 230V 50Hz Switching power 2000W 10A max cos 1 500VA 2 5A inductive cos 0 5 Time adjustment approx 5 sec to 7 min Twilight switch approx 5 1000 Lux Detection coverage 360 Range 6 to 16m depending on inst height IP protection IP20 indoors class II Installation Remove front lid by rotating it in an anti clockwise direction Mark 2 drill holes at the required po sition Drill holes fitting the dowels provided in the scope of delivery in both diameter and length insert the dowels in the d
4. rill holes Fix the de tector on the ceiling with the screws included in the package Bewegungs L melder Motion Sensor N sas Q seeeeeeeeeeee Detection Range frontal detection NOT SENSITIVE detection range approx 50 max 16m tangential detection SENSITIVE max 16m The 360 omnidirectional detection zone and the dense detection field guarantee an optimal function The range depends on the installation height and walking direction high sensitivity when cutting or changing a switching segment Since the detector reacts to temperature differences between heat source and ambient temperature the response may vary depending on the installation site floor heating hot environment etc Troubleshooting error cause amendment light does not turn on twilight adjustment value too low connected lamp defective check mains power fuses detector triggers without reason lightnever turns off check detection area for potential reason causes of false triggering draught animals heating etc may all provoke faulty switching detector is too sensitive reduce the detection range sensitivity or cover disturbing segments on the lens by adhesive tape check distances to lamps heat reflection or direct light influence connect RC element in parallel to transformers relais electric ballast twilight adjustment set too high lower the value turns the light on
5. tion The installation height should be about 2 to 4 m Wire the detector as follows phase outer conductor L brown neutral neutral conductor N blue switching output switched phase outer conductor L red Screw and tighten the detector to the ceiling The device is operational after approx 1 minute from connecting to mains voltage TIME The timer determines for how long the lights will remain on following the last movement in the detection area Choices are from approx 5 sec to 7 min Recommendation approx 2 min in staircases 7 min in restrooms etc LUX twilight sensor The twilight sensor regulates the operating threshold light value of the detector determining when the device should be activated Minimum value 5 lux moon symbol The detector will turn on the light at night Maximum value 1000 lux sun symbol The detector will turn on the light during daytime as well Recommendation approx 5 lux in staircases 200 lux in office spaces SENS sensitivity detection range Detection range adjustment max approx 16 m diameter walking person Should the detector be too sensitive triggering without movement in the detection range the sensitivity range can be reduced Push button operation The light can be switched on permanently through the installation of a break contact push button connected in series to the input phase Lights on and automatic operation interrupt mains power for at least 4 s

Download Pdf Manuals

image

Related Search

Related Contents

StarTech.com 6 ft Stereo Audio Cable - 3.5mm Male to 2x RCA Female  HP Pavilion dv6-6180us  Guía del usuario  Compressor Cooler Pro    Tarkett Felt FR 09.qxd:Layout 1  Samsung CE2933N دليل المستخدم  Untitled  

Copyright © All rights reserved.
Failed to retrieve file