Home
Where Does the GPRS M-Bus Master M Series Suitable for?
Contents
1. 1 Running the GPRS M Bus Master Configurator from the CD EA GPRS MBus Haster 1 0 ComPort Whole Operate J COMT1 Y ComPort M e Open Reboot Read Settings Clear Setting Com Setting Clear Display Mode Setting Mode Save Log DTU Setting HeartRate 60 S Riange 60 65535 Save rp 1 1 1 1 save PORT1 9700 Range 1 65535 Save IP2 250 290 250 250 Save PORT2 9700 Range 1765535 Save pgs ww aaabbbcccddd com Save APN CMNET Save Max 40 Character User Name G PRS User name Save Max 30 Character UserPsd GPRS user password Save Meter Setting Reading Periodic Time Range 60 60000 60 S Save Meter SH 60 Meter ID 10000060 Read Clear Add 2 Connection The RS232 cable included in the package connecting the RS232 DB9PIN to computer RS232 Port and the terminals to the unit power on the GPRS M Bus Master the device will contact to the computer please find out the Com Port at the computer s Device Manager page 3 Com Port Choose the correct COM Port then click Open button to Open the Com port after finished program please click the Close button to close the Com port If can not open the com port Page 7 of 9 King Pigeon Hi Tech Co Ltd Ver 1 0 KING PIGEON GPRS M Bus Master M Series x An Economical and Practical Solution For Remote Automatic A lt lt M Bus Smart Meter Reading System by GPRS In The Worldwide Http www GSM M
2. Actual bandwidth Receive Sensitivity Related Humidity Interface for configuration Meter interface Max Heat meters 10 Warranty 1 This system is warranted to be free of defects in material and workmanship for one year from the date of purchase 2 This warranty does not extend to any defect malfunction or failure caused by abuse or misuse by the Operating Instructions Page 9 of 9 King Pigeon Hi Tech Co Ltd Ver 1 0
3. OND VbS Sroaqd ee ONS REN KING PIGEON ED p OVL GSM RX TX POW GPRS AMR Unit GPRS Mbus Master GPRS Automatic Meter CM Ly Reading System 1 www GSM M2M com amp gt Data Center e Qh SL Em c a aan uus nmm n KAN S rrua Arhi S ey t m u PET ERO M Bus Meters meme 2M Bus Emaii S Total upto 60 120 240 360 M Bus Meters Heat Gas Water M16w GPRS MBUS Master RS232 Cable M Bus Meters ojs E Local Monitoring Center KING PIGEON GPRS M Bus Master M Series An Economical and Practical Solution For Remote Automatic Xs M Bus Smart Meter Reading System by GPRS In The Worldwide Http www GSM M2M com Table of contents 1 ENEMIES see SS SS SS SSE 3 2 eMC ANS TG ere eee ele a ec MD RR RN RR RID RR 3 3 Elena CUN RR RR RN RR RR RR 4 4 Bhysicelttayols eR aon OD 4 5 eelllocSuclconap dca lm c ER P I EM ER E CEPS cM MD MEME dM SEE AMEN d 5 o Msi RR RR RR M RR M E MN o 7 SENSO EE ERR KM ER MEM EM ERES 3 OSM uclocO ER EE RR RR RN DM RR 8 9 Weenncslspecilic9Mo nM EMEN ERR NE 9 10 G c o Q A 9 This handbook has been designed as a guide to the installation and operation of M Series GPRS M Bus Masters Statements contained in the handbook are general guidelines only and in no way are designed to supersede the instructions contained with other products We recommend that the advice of a registe
4. 2M com please check a the com port number is correct b the RS232 cable is connect correctly c click Com setting to change the Com port parameters 4 Mode Choosing the GPRS M BUS Master present mode in programming please choose Setting after setup all parameters please set it as Run otherwise the GPRS M Bus cannot work properly 5 Heart rate Please setup the GPRS heartrate to ensure the GPRS always online The unit is 10ms if setup as 0 stands for no heart rate 6 IP1 2 Server IP address IP1 2 Port The Server Port DNS Server DNS the port is 53 Default 7 APN User Name User PSD The GPRS Parameters please contact the SIMCard Operator to provide it usually can find out it at Operator s website or smart phones 8 Reading Periodic Time the interval time that the GPRS M Bus Master automatically reading the slave M Bus meters time after reading all of the slaves the GPRS M Bus Master will upload the meter current value to the server via GPRS 9 Meter SN Meter ID to setup the meter s ID numbers The meter ID is 8 digital Enter it and click Add to add meters click Clear to remove the meter 10 Reboot Click it to restart the GPRS Mbus Master 11 Read Settings Clear Settings Read the settings or clear the settings 8 Program Protocol The user can remotely program the GPRS M Bus master parameter via GPRS network or RS232 cable e g Server Periodic reading time add remove meters The commands should be i
5. VDC Positive 2A 12VDC The external power Ground The external power Ground negative DES S S for sample we only provide 12VDC 2A for project we can 110VAC 220VAC provide 110VAC 220VAC Version in order to protect engineer safety 5 Mainly Features 1 GPRS Data Transmission real time online data transfer no distance limitation 2 Embedded ARM Cortex M3 32 bit RISC MCU with real timeu C OS Il RTOS 3 Embedded complete PPP TCP IP protocol stack 4 Supports European standard M Bus Meter Bus interface for intelligent meters 5 Supports EN 1434 2008 protocol Intelligent meter communication protocol over GPRS network communication for up to 60 120 240 360 meters 6 Supports transparent and non transparent data transfer via RS232 or GPRS network 7 Supports point to point Point to Multipoint Multipoint to Multipoint Communication Mode 8 Supports up to 3 DNS and static data service center IP address 9 Plug and Play solution can realize data transmission between com port and internet 10 Supports RS232 three wire standard serial port rate speed up to 115200 BPS 11 Built in hardware Watch Dog Timer to ensure it reliable and stable 12 Supports remotely program the GRPS M Bus Master from server via TCP IP 13 Adopts application layer heartbeat technology to keep application layer stable connection 14 Running Stability 365 x 24 hours 15 Industrial class design suitable for long time wor
6. er 1 0 KING PIGEON GPRS M Bus Master M Series An Economical and Practical Solution For Remote Automatic M Bus Smart Meter Reading System by GPRS In The Worldwide Http www GSM M2M com Reasonable Use Please install the product at suitable places as described in the product documentation Avoid signal shielded by covering the mainframe Use Qualified Maintenance Service Maintenance can be carried out only by qualified maintainer 3 Standard Packing List GPRS M Bus Master X1 GSM ANT X1 User Manual PC Configurator X1 CD RS232 Cable X1 4 Physical Layout LED amp Interface Instruction ax ONS Vbs Sr2Q od jana OVL GSM RK TX POW GPRS AMR Unit GPRS Mbus Master Power indicator once powered on it will always on Transmit data indicator only transmitting data will flick Receive data indicator only receiving data will flick GSM Antenna Antenna core NN LIE o Page 4 of 9 King Pigeon Hi Tech Co Ltd Ver 1 0 GSM signal indicator flicks after power on online will flick slowly Overload Alarm indicator turn on 2s after power on then goes off If the overload alarm indicator always on stands for the GPRS M Bus Master connected too many meters please remove some of them KING PIGEON GPRS M Bus Master M Series An Economical and Practical Solution For Remote Automatic Xs M Bus Smart Meter Reading System by GPRS In The Worldwide Http www GSM M2M com OO EO The external power input 12
7. k applications 6 Installation 1 Only engineers can install the unit 2 While inserting the SIMcard please ensure the unit is power off 3 Please ensure the GPHS function of the SIMCard which install to this unit is enable 4 The GPRS M Bus Master should be installed in the position that person cannot get it and there re with a 110 220VAC 50HZ power source as well as enough GSM signal coverage 5 For sample we only provide rated voltage 12VDC2A version for project we will provide 110 220VAC rated voltage version 6 1 Insert SiMcard and install GSM Antenna Using a small thimble press the SIMCard Slot button the SIMCard Slot will pop up Put the Simcard to the slot the circuit side Gold side up towards and insert it back to the solt Then install the GSM Antenna See below Page 5 of 9 King Pigeon Hi Tech Co Ltd Ver 1 0 KING PIGEON GPRS M Bus Master M Series 1 An Economical and Practical Solution For Remote Automatic lt M Bus Smart Meter Reading System by GPRS In The Worldwide Http www GSM M2M com 6 2 Connecting the RS232 Cable to the PC for Program the diagram please see below 774 3 Me 2 2 RxD lo a 3 Tx Oa Ne ES 5 Ground Bu PC Si PR Device 6 3 Connecting the M Bus Meter to the GPRS M Bus Master the diagram please see below The GPRS M Bus Master capacity is limited the maximum quantity of the meters according to the M Series GPRS M Bus Master Comparison Table The diag
8. n ASCII code and each command should plus the Enter The character is Decimal The protocol is below Description Explanation Enter Setup Mode Enter into setup mode Setup Heart Rate SETHEART TIME xxxx xxxx stands for the value Setup APN Setup Server IP Setup IPt Com Por Setup Server IP Setup IP2 Com Por Setup GPRS User Name Setup GPRS User Password SETPSD xxox Setup Periodic Reading Time SET lt Jxx gt Xx stands for the time E g SET J180 to set it as 180 Setup Meter ID SET P1 xx 12345678 xx stands for the serial number of meter 12345678 stands for the meter ID E g set the 60 meter ID as 87654321 then send SET P1 60287654321 Page 8 of 9 King Pigeon Hi Tech Co Ltd Ver 1 0 KING PIGEON GPRS M Bus Master M Series An Economical and Practical Solution For Remote Automatic Xs M Bus Smart Meter Reading System by GPRS In The Worldwide Http www GSM M2M com Inquiry Meter ID SET lt P15xx gt xx stands for the serial number of meter e g inquiry the 9 meter then send Master Restart GPRS M Bus Master SETREBOOT Restart the GPRS M Bus Master 9 Technical specifications Specification Working Voltage DC12V2A Default 110 220VAC 50Hz Optional for project order Standby 50Ma Transfer data 300Ma Frequency 850 MHz 900 MHz 1800 MHz 1900 MHz PRS Network patents Rewer GPRS Class 2 10 CS1 S4 INCARD SM Connector Working Temp T gura Power Consumption Theory bandwidth
9. ompatible with EN 1434 2008 protocol and M Bus interface it supports 60 120 240 360 M BUS meter Slaves like M BUS heat meters M BUS Gas meters M BUS electricity meters M BUS Water meters and other M BUS meters and then transfer the meters data over wireless GPRS Network to Server The user can remotely setup the GPRS M Bus Master parameters via GPRS The GPRS M Bus Master will periodically automatic reading the meters and upload the meters value to monitoring center transparently The data format that uploading by GPRS is the same as the meters data format It is convenient for users to maintain its present monitoring center Where Does the GPRS M Bus Master M Series Suitable for The GPRS M Bus Master M Series suitable for below applications The Electricity Power Remote meter reading Remotely Heating meter reading Remotely other meter reading 2 Safety Directions Safe Startup Do not use GPRS M Bus Master when using GSM equipment is prohibited or might bring disturbance or danger Interference All wireless equipment might interfere network signals of GPRS M Bus Master and influence its performance Avoid Use at Gas Station Do not use GPRS M Bus Master at a gas station Power off GPRS M Bus Master when it near fuels or chemicals Power it off near Blasting Places Please follow relevant restrictive regulations Avoid using the device in blasting places Page 3 of 9 King Pigeon Hi Tech Co Ltd V
10. rams please see below Remote Data Center RS232 M Bus Meters Cable Local Data Center Notice 1 The Meter should be a Standard M Bus interface b Compatible with EN 1434 2008 protocol c If you use special meter or special protocol please inform us before you ordering products our R amp D will modify the protocol according to your special meters 2 MBUS Cable maximum length is 3000meters 3 The cable should be compatible with the standard ISO IEC 11801 2002 category 7 class F IEC 61156 5 2002 IEC 61156 7 USA ANSI TIA EIA 568A The cable using for connecting MBUS meters should be Dia gt 0 5mm Resistance lt 100 15 ohm km Loss lt 10 4 dB 100m FTP n 2 24AWG shielded type 4 The GPRS M Bus Master compatible with below brand meters Landis Gyr manage energy better Q kamstrup Dame SIEMENS H DROMETER Page 6 of 9 King Pigeon Hi Tech Co Ltd Ver 1 0 KING PIGEON GPRS M Bus Master M Series An Economical and Practical Solution For Remote Automatic M Bus Smart Meter Reading System by GPRS In The Worldwide Http www GSM M2M com w 7 Settings Notice While the GPRS M Bus Master the Run mode If GPRS failure the data will transmit to Server via RS232 Cable If GPRS is available the data will transmit to server via GPRS not transmit to server via RS232 anymore For testing the protocol of the meters compatible with server the user can use the RS232 cable directly
11. red electrician be sought before any Installation work commences King Pigeon Hi Tech Co Ltd its employees and distributors accept no liability for any loss or damage including consequential damage due to reliance on any material contained in this handbook King Pigeon Hi Tech Co Ltd its employees and distributors accept no liability for GSM Network upgrading or SIMCard upgrading due to the technology specifications contained in this handbook M Series GPRS M Bus Master Comparison Table 120 2 300mA 240 4 300mA 360 6 300mA Compatible with below meters kams hp SIEMENS H DROMETER Landis Gyr manage energy better Page 2 of 9 King Pigeon Hi Tech Co Ltd Ver 1 0 KING PIGEON GPRS M Bus Master M Series e An Economical and Practical Solution For Remote Automatic w gt M_ Bus Smart Meter Reading System by GPRS In The Worldwide 1 Brief introduction Http www GSM M2M com The GPRS M Bus Master M Series is a wireless GPRS Automatic Meter Reading AMR System It embedded with high performance ARM Cortex M3 32 bit RISC MCU with real timeu C OS II RTOS and industrial GPRS Engine inside It is special for communication between monitoring center and M Bus meters intelligent instrument and industrial meters over wireless GPRS Network It is the best solution for meter reading master station or controller The GPRS M Bus Master M Series is special for automatic meter reading AMR system c
Download Pdf Manuals
Related Search
Related Contents
User Manual (Analog) New Build Western Digital My Passport Ultra Metal Edition, 1TB Weider WEEVSY3953 User's Manual USER`S MANUAL FOR VEAVIEN DIMMER NZS 4230:2004 USER GUIDE fs curtis ml series air compressors user manual Mode d`emploi User Guide - Etabeta electronics spa Copyright © All rights reserved.
Failed to retrieve file