1. Pulse Series Remote Monitoring Systems Operations Manual Document 701009 Version 1 0 Welcome Welcome to the Accurate Logic Pulse Series Remote Monitoring System Operations Manual The primary purpose of this document is to allow your personnel to become familiar with the system s equipment and its operation The secondary function of this manual is to serve as a training guide consequently you will find more equipment and process detail than in a typical industrial user s manual Accurate Logic 128 Saturn Court KECURATS Indialantic FL 32904 USA _Ocic Phone 321 779 0062 Fax 321 779 0062 Contents CLONE SEALE sac ccscecosccesicesacestusesseudsacessscevsscessvenecestetacsasivecessiaveneess 4 PDOUE HIS GUIGS sessi eiai EEE EEES 4 Seine np he Syste sessar irn aroen r anaE NE T 5 Hae e e saenceecaaceadomssenceamancemonsaescaecinet 5 Pulse Software Setup eessessseoeeessssssssseerrsssssssseerresssssseeeresssss 6 PAE e E E E E E 7 SOS ED e E tes Matessraetewices 8 Advanced Sensor SOUP sisavacetsotadensacanscsansnoeedansdwaeeaencedensacanete 10 Fiat CU a E N 12 SEAE e T E AE E T 16 SCUMP COMPOS sses EEE EE EE 18 Paalse F CAUUE OS sssi 19 Viewing Count Details aise sticecsesawiesaiseacanndssndadaieadieestsawitsahtavaned 19 Resetting Count Details saiiscrsiasencosiaiadeserarendssonsaacseiarennsodesaanees 23 Endails irom Your POISC secerneren 24 Viewing Graphs on Pulse Unit ee cccccccccee
2. Use keypad keys to enter the password and then press Enter Configuration Access System Configuration Screen Reset Daily Totals shown on Details Screen and related emails Reset Weekly Totals shown on Details Screen and related emails Reset Monthly Totals shown on Details Screen and related emails 23 Emails from Your Pulse The Pulse can send a variety of emails e RemoteCall Emails to let the recipient know when there is a problem with the Pulse e Query Emails to inform the recipient the results of a query done on the Pulse e Daily Emails to inform the recipient of the totals for the day e Weekly Emails to inform the recipient of the totals for the week e Monthly Emails to inform the recipient of the totals for the month In this section we will discuss and show the Daily Weekly and Monthly emails RemoteCall emails are discussed in the Sending a RemoteCall section and Query emails are discussed in the Querying Data on Pulse Unit section 24 The Pulse Daily Weekly and Monthly Totals emails are sent at midnight They will give the totals for each sensor installed on the Pulse unit Subject Received C PULSE LINEA COM Pulse Weekly Totals Fri 7 27 2007 12 05 PM gt PULSE LINEA COM Pulse Daily Totals Fri 7 27 2007 12 03 PM Pulse Daily Totals Message Plain Text File Edit view Insert Format Tools Actions Help jaa Reply i iReply to Al cg F
3. Eeee eee eee T nooo o Oooo k ODODO ooo ce aced ao anon oa amp Oona panoaoaf pooococooo SS Note This data file is an excellent source for creating graphs 34 Sending a RemoteCall If the operator notices trouble on the line that a sensor is monitoring they can send an emergency email to the address that was setup in the RemoteCall Email Configuration Screen This email will be sent immediately and notify the recipient of which sensor is having a problem To send a RemoteCall the operator just needs to press and hold the button for the line that is having problems When the button starts to blink red the user can release the button Subject Received Assistance Requested on Line A Message Plain Text i File Edit View Insert Format Tools Actions Help Reply L Reply to All L Forward c aea e LOK me ee AO From PULSE LINE4 COM Sent Mon 7 23 2007 10 49 PM SUPPORT ACCURATELOGIC COM Subject Assistance Requested on Line 4 lt RemoteCall Sent from PULSE 35 Making Changes to Your Pulse Turning On Off Count Display on Unit The counts shown on the Main Pulse Screen can be toggled on or off for each sensor 1 Configuration Button Access Password Screen 2 Password Box Use keypad keys to enter the password Enter Administrator Password and then press 0000 Enter Configuration 3 Sensors Button Access Sensor Configuration Screen Sensors 4 Show button Toggle On O
4. Foot ACC CBL4 50 4 Wire 50 Foot 4 Wire NPN Sensor Hookup coll of ACC SPLT M12 Sensor with RemoteCall Box ACC SPLT M12 ACC REMC STD 47 Appendix B PIN 3 PIN 4 Blue Black Common Sensor 0 VDC Signal RemoteCall Supply Signal PIN 2 PIN 1 24 VDC White Brown Pulse M12 Sensor Connector Pinout 48
5. Network asbine 1D ily History DATO Data Log W 192 168 1 105 CPU 224 ReEL 2 5 Data Log a A 256k Memory Cartridge AN Line 3 Daily History DAT2 Data Log S 256k Memory Cartridge EN Line 4 Daily History DAT3 Data Log 33 This will open the data file using Microsoft Excel The dates are listed on the left most column This data file is broken up by day and hours This data file will show all of the data the sensor has collected since it was installed This file can hold three 3 years of data and will start rewriting from the oldest date after the three years are over E Microsoft Excel 197 168 1 105 Line 1 Daily History 7 49 2007 17 77 PALcev t J Kk CL mm n F Li Tam Li Bam Li Sam Li ifam Li fiam Li _t2pm Li_ipm Li 3p nase amp amp oS Soo o Bech otesho cs 7 Faro g Saar 9 eama 10 3a 1 2007 Ti enaar 43 7 anonr 13 722007 qa 772007 15 62 2007 ib 621 007 47 6202007 18 692007 suff aj a t D O OO OOG OGOUN OO GOGO OQO GOGH da OO OGG j i ay Ooo coo oo oO oOWooO b OO OOO oe Ao D E o D L a B4 Go Sora DOOD D S O O S O O DODO OOO O z ETAT EATE ant a amp 0 OOO 00O 0O ODO OO DO O i ad ahd re EJ t Fa ooolo Ga anaoa doal Olaa ala alao Gala a m si Ts ja ui al FS a o olole olo olola Yolo ciclo olo ol dle Blz nogecosecabtaocegecas ooooolooootiolooliodoolcs ie 15 Dooocooocooconooocooonnoononcoonn Fs U i i
6. is given because some sensors are only sold one way Sensor On Sensor Off The Sensor must be On or Off for at lt 100ms lt 100ms least the specified amount of time in order for the Pulse to count it When finished entering in the Advanced Sensor information press the button to return you to the Configure Sensors Screen 11 Email Setup Press the al button on the Main Configuration Screen This is where you need to setup all email information for the Pulse unit SIMATIC PANEL Configure E Mail adress MON o00 ff o00 f ooo EE 000 LOADING E MAIL DATA Label for which Pulse E Mail is FROM 001e O101 010101010101 0101010101010100 0101010101 0101010101010100 O1O1 O10010 Ex Pulse UnitA com SAVING E MAIL DATA SAVE ALL EMAIL SETTINGS REPORTS HONOL BACK DO NOT SAVE REMOTE CALL 12 FIELD DESCRIPTION You will need to N _o00 _000 000 000 Port 000 enter the SMTP address and Port Number for the email account that will be sending all the graphs and queries Your IT Technician should supply you with this information Note You can change the default email address that will be used when emails are sent Just click the box in the middle of the screen and use the keypad to enter the new email address It must be in a legal address format Next press the Reports Button to setup the email addresses of the people who will be receiving the daily weekly
7. to the file It is broken into four files one for each sensor To view the log file generated by the Pulse unit you will need to download Siemens S7 200 Explorer You can download this program directly from the Siemens website or from a link on the Accurate Logic website www accuratelogic com Once you have the program click to install Follow the online instructions Once you get to the menu where you have to set the PG PC Interface choose the T CP IP Auto gt YOUR ETHERNET CARD The program will finish installing and you must then restart your computer Once the program has been installed start it by clicking the S7 200 Explorer icon t My 57 200 Network File Edit view Favorites Tools Help Back QJ Ss Search E Folders Gz Address fe 1 20D04FE0 34E4 1069 42D8 080026830309D F2312111 7024 46C0 9B5D 0497BDB4E269 X Address Type Error Communications Time out Check t Unknown Device gt Expand Explore Open Browse with Paint Shop Pro 9 Set PG PC Interface IP Address Browser Properties Help This will open the explorer program Right click on My 7 200 Network under folders and then choose IP Address Browser 31 Click the New Address button and type in the IP Address of the Pulse Unit and a description then click the Save button Click the OK button when finished IP Address Browser There are nolP Addresses currently defined on your sys
8. 000 0000000 _ 2 Daily Graph Button View Daily Graph DAILY GRAPH 26 Viewing Monthly Graph This graph displays the count for each day of the current month It also shows the Best Day of the month You can use the scroll buttons to see the specific numbers for each day This display restarts at 12 00 am on the 1 of the each month SIEMENS SIMATIC PANEL Monthly Graph of 000000 January Best Day 00 for 0000000 HONOL Current Day 00 Total 0000000 To 1 Sensor Display Line View Sensor Details Screen SHIFT TODAY THIS WEEK 0000000 0000000 0000000 2 Monthly Graph Button View Monthly Graph MONTHLY GRAPH 27 Querying Data on Pulse Unit Querying Data for a sensor will show many different details for the days and times input Total Production Best Daily Total Best Hourly Total Hours Up and Hours Down This screen also shows the Average Parts Per Hour for Up Time First Day and All Time SIEMENS SIMATIC PANEL Query Of 000000 EB N Month Start Day Start Hour 12 AM P Loading Data y Calculating Results End Day End Hour E Total Production 00000000 babes S Best Day 000000 on Day 1 Best Hour 000000 on Hour 12 AM HONOL T Hours Up 000 Hours Down 000 EMailing EMAIL QUERY Note Hours Up is the number of hours for the time input that the Pulse unit actually recorded counts Hours Down is the number of hours for the time input that the Pulse u
9. EL Configure Ethernet a HONOL Current Settings IP 000 000 000 000 Subnet 000 000 000 000 Gateway 000 000 000 000 SAVE and EXIT MAC 00 00 00 00 00 00 Sensors Setup You need to configure the Sensors that you plugged into the unit by pressing the sensors button on the Configuration Screen SIEMENS SIMATIC PANEL Configure Sensors Name 1 K 2 KU H NOL 3 4 000000 FIELD DESCRIPTION Name Pressing the Name field allows you to name the sensor The sensor name can be up to six 6 characters long Press the Name field and use the keypad keys to enter the name and press the return button when finished Note If you enter more than six 6 characters and press the enter key the name will not be saved If you would like the counts to be shown on the Pulse Unit toggle the Show option to Yes If you would like hourly counts to be permanently logged to a log file the Log button needs to be toggled to Yes This data can be viewed using Siemens S7 200 Explorer and Microsoft Excel You should set this to Yes for every sensor that you have connected Note This feature will be discussed in greater detail in the Viewing Log Files section When finished entering in the Sensor information press the se button to return you to the Main Configuration Screen Advanced Sensor Setup Each Sensor can be custom configured to fit the product that it is c
10. cesseeeseeeeeeeeeees 26 Viewvme Daly Graphi secesii ona E bettbia Rectan ts 26 Viewing Monthly Graph eeeeessssenenesssssssseeersssssssseseresssssseses 2l Querying Data on Pulse Unit eenseesseoeeensssssssseeresssssssee 28 Yia OS ee pees cota eaceenes Sea ceamseaseeaet 31 Sendine iy CTO A oo ste cceucsee nceassemesncnecotovesstusaneceas anus 35 Making Changes to Your Puls eecccccsssseecccccsssssccececcsssssesee 36 Turning On Off Count Display on Unit eseesseeeeeeesssssseeeeeees 36 Changing Sensor Name visesssccncendcoueseedncaseceansucnedaasancttacnuossosananaes 37 Changing Email Addresses cccsdscdsessesaacneaderdseaansiavanedeedsearoscacsaces 38 Changing Reports Email cccccccccccccccceseeeeeeeeeeeeeeaeeeenees 38 Changing Remote Call Emiail ccccccccseesssseeceeeeeeeeeeeeees 39 Chane mne Fma LADE leie e E NETE E 39 Changing Date TIME accencecapesinnenseuitsdencsennedsarnoccnbastaaasenuniedesieenncs 4 Changing Administrator PaSSWOTd ccssseeseceeeeeeeeeseeeseeeeees 42 Changing Screen Contrast ss 0c5ccuden cossuncsiereidenstsaalenecacnentnensavedevnees 42 Changing Ethernet Information ssesssseeeeessssssseseeesssssssseeeees 43 TOMI CSO OUING sssrinin nonkaa enin EEEa Enei 45 Appendix A Appendix B Getting Started Pulse is an industrial self contained remote monitoring system It gathers data out on the production floor that can be viewed via the web anywhere in th
11. e world or as close as your office About this Guide This guide describes e how to setup the system e the basic features of your Pulse Series Remote Monitoring System e how to make basic changes e how to perform troubleshooting Setting up the System The system has hardware and software that needs to be setup before the system can start running When configuring the Ethernet and Email settings an IT technician will be required Hardware Setup The hardware setup is easy to configure N Supply power to the unit EA Setup the sensors where you would like to monitor Connect the Ethernet port to your network Pulse Software Setup To enter the configuration setup for the Pulse unit press the toolbox button This should bring up the Configuration Screen You should configure the system in this order Ethernet Sensors Email System SIEMENS SIMATIC PANEL Configure Your Pulse Ethernet Sensors HONOL E Mail System Ethernet Setup Press the _ Fthemet button on the Main Configuration Screen You will need to enter an IP Address Subnet and Gateway for your Pulse unit Your IT Technician should provide with you with this information Simply click on the screen and use the keypad to enter the information Click the save and exit button after you have finished Note The MAC address will be shown on this screen if your IT Department needs it SIMATIC PAN
12. ff Counts Display on Show Unit No Note This will not stop the count This only stops the counts from displaying on the unit itself Once the display is turned off the Details Screen will be unavailable 36 Changing Sensor Name The sensor names can be renamed at any time Because the Sensor name affects the emails that are sent any changes made to sensor names need to be saved through the Email Configuration Screen Toolbox Button Access Password Screen Use keypad keys to enter the password and then press Enter Configuration Sensors Button Access Sensor Configuration Screen Sensors Name Display Box Use keypad keys type in new sensor you wish to change name Name Back Button Return to Main Configuration Screen BACK Email Button Access Email Configuration Screen E Mail Save All Email Save changes made to sensor names Settings Button so they will be changed in the emails SAVE ALL EMAIL SETTINGS Note The sensor name can be up to six 6 characters long If you enter more than six 6 characters and press the enter key the name will not be saved Changing Email Addresses Changing Reports Email You can change the email addresses of where the daily weekly monthly and query reports get sent 1 Toolbox Button Access Password Screen x 2 Password Box Use keypad keys to enter the password and then press 0000 Enter Configuration 3 Email Button Access Email Configura
13. g should be ready to go You should now have a working Pulse Press the button to access the Main Pulse Screen 18 Pulse Features Viewing Count Details Viewing count details for each sensor is very simple Just look at the Pulse unit The Main Pulse Screen shows the counts for each sensor installed It shows totals for the current shift day and week SIMATIC PANEL Series 450 Production Statistics amp Monitoring 12 31 2000 10 59 59 AM SHIFT TODAY THIS WEEK 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 19 You can also view sensor details on your company s network Just type the IP Address of the Pulse Unit in your web browser and you can view Daily Weekly and Monthly data for each sensor i LS ee Xs E ap c cone Production Statistics amp Monitoring Name Daily Weekly Monthly A j __14786 __58420 375452 E j _ 14441 f 62146 _ 455250 j __22840 51954 _ 485765 D j __15989 67898 412111 Time amp Date of Report 02 05 05 31 07 Note If the sensor name is grayed out then there has not been any production for the period of time specified on the Advanced Sensor Configuration Screen This time is configured by the operator during the initial setup 20 If you wish to view even more detailed information for each SHIFT TODAY THIS WEEK 0000 0000000 0000000 J sensor simply click the Senso
14. monthly reports and queries 13 FIELD DESCRIPTION SIMATIC PANEL This Reports Screen is where Configure Report E Mail you will need to add email addresses that the Daily Weekly Monthly and the Query emails will be sent to Just press the appropriate data box and use the keypad to enter the address You have the option of turning off these emails by toggling the buttons to No Press the Back button when finished Note You have the option of turning off these emails by toggling the buttons to No Next press the RemoteCall Button to setup the email addresses of the people who will be receiving emergency emails when RemoteCall buttons are pressed 14 FIELD DESCRIPTION SIMATIC PANEL Just press the appropriate data Configure RemoteCall E Mail box and use the _ keypad to enter No 200000000000000000000000000000000000000000000 the email address You have the option of turning these emails on and off by toggling the buttons to Yes or No Press the Back button when finished Once all email addresses have press the Save all Email Settings button When finished entering in the email information press the button to return you to the Main Configuration Screen 15 System Setup Press the System button on the Main Configuration Screen You will be taken to the System Configuration screen This is where you need to se
15. ng on the Pulse unit Possible Cause The network cable is not connected or there are network difficulties The Pulse Unit is recovering from a power failure If the Pulse unit has been turned off for an extended period of time the pulse s internal web data will need to be reloaded The Show option was not set to Yes on the Configure Sensors screen 45 Solution Plug the cable back in or call your IT Dept Wait 30 seconds and Pulse Unit should power back on No data will be collected during this boot up time Press the button on the System Configuration screen This button allows the web data to be reloaded The button will only be displayed if the system thinks the web data has been corrupted or lost Please follow instructions for Sensor Setup under Setting up the System section Load WEB Problem Possible Cause Solution Log file does not The Log Please follow contain any data option was not instructions for Sensor set to Yes on Setup under Setting the Configure up the System Sensors screen section If your Pulse is having problems click the warning button on the main screen This will give further details If the problems are recurring frequently please contact Accurate Logic Technical Support at 321 779 0062 46 Appendix A 3 Wire NPN Sensor Hookup gt AAA ACC CBL4 10 4 Wire 10 Foot ACC CBL4 25 4 Wire 25
16. nit recorded zero counts 28 To query a sensor 1 Sensor Display Line View Sensor Details Screen SHIFT TODAY THIS WEEK 0000000 0000000 0000000 2 Query Button View Query Screen QUERY 3 Month Display Box Use Keypad to Choose Month Month 4 Start Day Box Use Keypad to choose Start Day Start Day tons nery 5 End Day Box Use Keypad to choose End Day 6 Start Hour Box Use Keypad to choose Starting Start Hour 12 AM 7 End Hour Box Use Keypad to choose Ending 29 The Query results can be emailed to the address setup in the Email Configuration Screen by pressing the Sey button Ty g From Subject Received PULSE LINES COM Statistics Report From Pulse Tue 7 31 2007 10 43 PM Statistics Report From Pulse Message Plain Text i File Edit View Insert Format Tools Actions Help a Reply_ Reply to All Forward aJ b4 P S AK ar o gt A O From PULSE LINEA COM Sent Tue 7 31 2007 11 18 PM To SUPPORT ACCURATELOGIC COM CE Subject Statistics Report From Pulse Line 4 Month 6 Days 1 to 31 Time 0 00 to 23 59 Total 5849452 Hours Up 360 Hours Down 384 Average Up 16248 48 First 16762 50 All 7862 17 Best Day 5 489792 Best Hour 9 31827 30 Viewing Log Files What is a log file Log files contain all data collected since the unit was first installed The Log option has to be turned on in the Configure Sensors Screen in order for data to be written
17. orward c From PULSE LINEA COM Sent Fri 7 27 2007 12 05 PM Toi SUPPORT ACCURATELOGIC COM Pulse Monthly Totals Message Plain Text DBR i File Edt wiew Insert Format Tools Actions Help Daily Totals for a Reply Reply to All Forward oa aleg 14786 t 14441 Pulse Weekly Totals Me From PULSE LINEA COM Sent Fri 7 27 2007 12 05 PM 22640 File Edit Yiew Insert Fg SUPPORT ACCURATELOGIC COM 15989 F re a Repl 4 Reply to All tei att 4 Subject Pulse Monthly Totals Subject Pulse Daily Totals 5 3t aw Se From PULSE LINES COM SUPPORT ACCURATE 375452 455250 Subject Pulse Weekly Totals 465765 412111 Weekly Totals for AL 58420 B 62146 51954 D 67696 Note The recipient of these emails can be changed at any time Please see Changing Email Addresses for further instructions 25 Viewing Graphs on Pulse Unit Viewing Daily Graph This graph displays the count for the 24 hours of the day It also shows the Best Hour of the day You can use the scroll buttons to see the specific numbers for each hour This display restarts at 12 00 am SIEMENS SIMATIC PANEL Daily Graph of 000000 January i Best Hour 00 for 000000 HONOL Current Hour 00 Total 000000 1 Sensor Display Line View Sensor Details Screen SHIFT TODAY THIS WEEK 0000000 0000
18. ounting Most of the time this won t be needed but some products may need some fine tuning Press the ADVANCED button on the Configure Sensors Screen to access the Advanced Sensor Setup SIEMENS SIMATIC PANEL Configure Sensors Advanced No Activity Type Sensor On Sensor Off lt 100ms lt 100ms lt 100ms 1 000000 N O 2 000000 rs re i HONOL 3 000000 rr ro 4 000000 w re io 100ms 1 seconds enter 600 for 10 minutes For example suppose you are measuring a box of cereal If you have the Type field set to Normally Closed the On field will be how long the box of cereal will be in front of the sensor x100ms and the Off field will be the usual length of time before another box of cereal will meet the sensor However if you have the Type field set to Normally Open the Off field will be how long the box of cereal will be in front of the sensor 10 x100ms and the On field will be the usual length of time before another box of cereal will meet the sensor FIELD DESCRIPTION peep This field will be the length of time before the sensor will report non activity This non activity will be shown on the Pulse Mail Screen as a in front of the Sensor Name If you use the network to view the report then the sensor name will be grayed out The Type option allows you to set the sensor to Normally Open N O or Normally Closed N C This option
19. ox Use keypad keys to enter the password str and then press Enter Configuration System Button Access System Configuration Screen System Keypad Keys Use keypad to Change Date Time ine oo Set Clock Button Save Date Time Information Set Clock 4 Changing Administrator Password There may be a time when you need to reset the date time of the Pulse unit Use keypad keys to enter the password and then press Enter Configuration 3 System Button Access System Configuration Screen System 4 Administrator Enter New Password 4 numerical Password Data Box Changing Screen Contrast You can change the color contrast of the screen Use keypad keys to enter the password and then press Enter Configuration 3 System Button Access System Configuration Screen System 4 Contrast Increase Change color contrast of the screen Contrast Increase 5 Contrast Decrease Change color contrast of the screen Contrast _ Decrease Changing Ethernet Information You can change the IP Address Subnet and Gateway information Access Password Screen Use keypad keys to enter the password and then press Enter Configuration 3 Ethernet Button Access Ethernet Configuration Screen Ethernet 43 5 Save Button Save New Ethernet SAVE Information 44 Troubleshooting RemoteCall lights are flashing a blinking on Main Screen Web page not showing data Counts are not showi
20. r Display Linet This will take you to the Details Screen for that sensor which will show counts for the current hour current day current week current month current shift and the Call Count The Call Count is how many times a RemoteCall has been made for that sensor that day It is the logical state of the sensor SIEMENS SIMATIC PANEL Details of 000000 THIS HOUR TODAY THIS WEEK _ _THIS MONTH CALL COUNT SHIFT _000__ 0000000 OEEO HONOL RESET SHIFT TOTAL MONTHLY GRAPH 21 Sensor details can also be seen on this screen If the black circle to the left of word Sensor 1s visible then the sensor is off If the white circle to the right of the word Sensor is visible then the sensor is On If the black circle is showing then the Sensor is off If the white circle is showing then the Sensor is off Note Call Count will be reset at 12 00 am every night Note Shift total must be manually reset at the end or beginning of each shift by pressing the ER If this button is not pressed it will continue to count indefinitely until the button is pressed 22 Resetting Count Details To reset the daily weekly and or monthly counts Toolbox Button vis Password Box Enter Administrator Password 0000 System Button System Reset Daily Button Reset Daily Reset Weekly Button Reset Weekly Reset Monthly Button Reset Monthly Access Password Screen
21. tem Click New Address to add IP Addresses for use IP Address Description si Address amp TSAP Properties IP Address 192 168 1 105 Description for thie address Pulse Unit New Address a2 The Pulse Unit IP Address should now be listed Double click the IP Address My S7 200 Network File Edit View Favorites Tools Help Q Back BD Search E Fetters Address hcl 1 20D04FE0 34E4 1069 42D8 D5a088 IDFA 4 46C0 9B5D 0497BDB4E269 Folders Address Type Ta My 57 200 G t j 192 168 1 105 CPU 224 REL 02 01 57 200 PLC WB 192 168 1 105 CPU 224 REL Then double click 256k Memory Cartridge A My S7 200 Network 192 168 1 105 CPU 224 REL 02 01 SEE Ay File Edit view Favorites Tools Help Q Back P D A Search Key Folders fz Address My 57 200 Network 192 168 1 105 CPU 224 REL 02 01 h lt Go Modified Created Folders tame lt FS my 57 200 Network i 256k Memory Cartridge B 192 168 1 105 CPU 224 REL fatal 7 18 2007 11 18 AM 10 2 2006 9 15 PM T Data Block 6 11 2007 11 17 AM 10 2 2006 9 15 PM T System Block 6 8 2007 7 10 PM 10 2 2006 9 15 PM This will bring up the sensors installed on the Pulse Unit Double click the sensor you want to see the details for 256k Memory Cartridge File Edit view Favorites Tools Help Q peck amp P Search Key Folders Ei Address a 256k Memory Cartridge Folders irs T My 57 200
22. tion l Screen E Mail 4 Reports Button Enter Configure Reports Email REPORTS Screen 5 Email Display Box Use keypad keys type in new email address 6 Back Button Return to Email Configuration BACK Screen 38 7 Save All Email Settings After changes have been made Button press the Save all Email SAVE ALL EMAIL SETTINGS Settings button Changing Remote Call Email You can change the email addresses of who gets the emergency emails when the Remote Call buttons are pressed on the Pulse unit Toolbox Button Access Password Screen Use keypad keys to enter the password and then press Enter Configuration Email Button Access Email Configuration Screen E Mail Remote Call Button Enter Configure Remote Call REMOTE CALL Email Screen 5 Email Display Box Use keypad keys type in new email address Changing Email Label 39 When emails are sent from the Pulse unit they come from an address which can be changed Toolbox Button Access Password Screen l Password Box Use keypad keys to enter the ninistrator Passy password and then press Enter Configuration Email Button Access Email Configuration Screen Email and ae Box Use keypad to enter the Email Address Note The email address must be in a legal format 40 Changing Date Time There may be a time when you need to reset the date time of the Pulse unit Toolbox Button Access Password Screen Save B
23. tup the date time and administrator password for your unit SIEMENS SIMATIC PANEL System Configuration Calibrate Contrast Contrast Touch Increase Decrease Day Mnth Year Hour Min Sec Set Clock 00 Jan f 2007 00 4 00 J 00 HONOL Update Takes Day of Week 10 Seconds an Current Date 12 31 2000 10 59 59 AM Reset Daily Reset Weekly Reset Monthly Administrator Password 010100 Load WEB 16 FIELD DESCRIPTION Day Mnth Year Hour Min Sec Click the date Set Clock Y Jan ff WA O 0 0 time and day of Update Takes Day of Week week fields and 10 Seconds Ea Current Date 12 31 2000 10 59 59 aM USe the keypad to enter the correct information Press the Set Clock button to save the information entered The new information will appear under Current Date Click the Administrator Password Box and use the keypad to enter a four 4 0000 digit number password Default password is 0000 Administrator Password Note You can Calibrate the Touch screen functionality by pressing the Calibrate Touch button Use your finger or a stylus and follow the simple instructions given Note You can reset the Daily Weekly and Monthly counts shown on the Details Screen by pressing the reset buttons More on this in the Pulse Features Section When finished entering in the date and time press the button to return you to the Main Configuration Screen 17 Setup Complete Everythin