Contents

1. EP300 COM1 side EXPLC side 2 RX 2 TXD 3 TX 7 RXD 5 GND 3 GND 009 9PIN female D SUB up view of cable 8PIN male MINI DIN up view of cable EP300 to Mitsubishi PLC FX series EP300 COM1 side FXPLC side 8 TD 2 RD 9 TD 1 RD 6 RD 7 TD 7 RD 4 TD 5 GND 3 SG 00 9PIN female D SUB up view of cable EP300 to LIYAN EX232BD EP300 COM1 side 8PIN male MINI DIN up view of cable EX232BD side 2 RX 2 TXD 3 TX 3 RXD 5 GND 5 GND 9PIN female D SUB up view of cable 9PIN male D SUB up view of cable Shake against dir ci 2h rections per 2 hours LLL Pin Arrangement LLL Strike against 10G X Y Z three directions per 3 times Cooling method Air convection to be cool naturally CON2 Weight EP300 289g EP314 330g include steady RS 232 9PIN D SUB Female 2 TX 3 RX aan Wiring Diagram EEE 5 GND PC to EPPLC PC side EPPLC COM2 side COM1 2 RXD 2 TX 3 TXD 3 RX RS 232 RS422 485 9PIN D SUB Male 5 GND 5 GND RS232 RS422 485 7 RTS 2 RX 6 RDA RD 8 CTS pa 7 RDB RD 8 TDA TD 5 GND 9 TDB TD 9PIN female D SUB up view of cable
2. 85 lt 135 136 5 gt Thickness Range 0 5 2mm Specifications aan 1 General specification Item EP300 EP314 Screen STN LCD Color monochrome Setting range of backlight auto closed 1 99 Backlight minutes value 0 is not closed Life is about 50 000 hours at 25 C g Number of dot 128 X 64 dots D Range of EN lt display 67mm W X 32mm H 3 00 Diagonal Contrast 10 section contrast Language ASCII character Font Taiwan Traditional Chinese BIGS code Size of word LCD contrast VR adjustment LCD backlight LED backlight COM1 Fane y RS232 Non synenranous transmission method g RS422 485 Transmission speed 9600 bps or 19200 bps D 5 Oo COM2 Non synchronous transmission method r y RS232 Transmission speed 9600 bps or 19200 bps o 2 Electric specification Item EP300 EP314 External power 24V 100mA Max Function key Numeral key 0 9 A F F1 F6 ESC SFT CLR ENTER and Direction keys Capacity of memory EP300 256KB EP314 64KB RAM of system 32KB Communication interface COM1 RS232 RS422 485 COM2 RS232 Protection of panel IP65 Temperature of using hardware 0 50 C relative humidity 20 90 RH without condensation Temperature of storing hardware 20 60 C 0 5mm displacement 10 55Hz X Y Z three EP300 to LIYAN PLC EX series
3. 24V 1 vec ee Circuit T 4B S S l XOH l 1 Xoo LI Input DC24V 10 15 DC24V 10 15 voltage Input 7mA DC24V 7mA DC24V current Impedance 3 3 KO 3 3 KO Response About 10 ms X00 X07 High About 10 ms X00 X07 High time Speed Speed Input No voltage contact or NPN open No voltage contact or PNP open pattern collector collector Circuits Photo coupler Photo coupler isolation Output Specification Item Relay output Transistor output So VW a Aree amp RY S Circuit ji Load Under AC250V DC30V DC5V 30V voltage Rated 2A 1 point 0 5A 1 point current Rated capacity 100W 12W Response time About 10ms Under 1 ms Circuits Machine isolation Photo coupler isolation Front view unit mm Dimensions EEH 97 SANE NNNN HNNNN Esc f l gt a na 4 Q e a RUN lt 146 Back view dq UUUUUUUUUU O Gb FG w p Gb O q ANNANNANNANNN Lateral view M a A A000000 Vertical view unit mm Cum T t Loo doo y Dimensions of inserting hole unit mm
4. 9PIN male D SUB up view of cable COM1 communication mode 4PIN Dip Switch 4PIN Dip Switch RS232 RS422 485 SW1 SW2 OFF ON SW3 SW4 ON OFF controlling frame refer to Example program information Operating Sequence ann POWER ON Press ESC anytime it will come back to main frame User editing screen X device increase Set PLC Monitor status RUN STOP of X device X device decrease Adjust low Y device increase power of back light Monitor status of Y device Y device decrease M device increase Monitor status Continue to press 2 sec Buzzer of M device then fast move mode Adjust M device decrease S device increase Copy Monitor status Continue to press 2 sec program of S device then fast move S device decrease D device increase Continue to press 2 sec Date Time of D device then feet ae 16 bits Monitor status D device decrease D device increase Monitor status Set station f D devi Continue to press 2 sec number G ewe then fast move 32 bits D device decrease Search device number and Set new value Monitor status of D or D device D 16 bits D 32 bits Input Device Change No 4 Device Data Jump to Value of inputted device i device evice is number changed Ene Example Program EEE M8013 Yoo4 Yo05 M4 M8013 INCP D998 D996 ASCIP D996 D4537 K8 M8013 i ASC abcdefgh D
5. 4512 ASC 87654321 D4518 ASC Liyan D4522 ASC Electri D4526 ASC c D4530 M8013 ii ASC 12345678 D4512 P D4518 M8012 DINCP DO DDECP D2 DADDP 10000 D4 DADDP K 10000 D6 D6 In this mode register D4000 D4999 can not be used for other purpose This mode can display 20X8 letters in English User just move letter which you want to display to corresponding register by MOV or ASC command then it will be ok Corresponding form between Screen and register D4512 D4513 D4514 D4515 D4516 D4517 D4518 D4519 D4520 D4521 D4522 D4532 D4542 D4552 LIYAN ELECTRIC INDUSTRIAL LTD No 8 Alley 32 Lane 667 Chung Shan Rd Sheng Kang Hsiang Taichung Hsien Taiwan TEL 886 4 25613700 FAX 886 4 25613408 WEBSITE http www liyanplc com E MAIL twliyan ms16 hinet net L U LU U L a G a G a A E G i D4562 D4572 a a G a G E A S A S G E G A N G S G S G R G E G S G E G S D4582
6. PROGRAMMABLE LOGIC CONTROLLER EP series PLC USER S MANUAL Before using EP series PLC please read this user s manual in detail Input power of EP series PLC is DC 24V When connect the wiring please turn off power This panel is protected against water but it is not protected against oil or corrosion liquid When using it please avoid using sharp goods to scrape the panel When fix the panel please use a steady which is attached by original manufacturer To avoid the case is damaged please do not lock the screw too tight Introduction EEE EP series is programmable logic controller PLC with human machine interface HMI LCM is 128x64 dots It can display 8X4 words in Chinese or 16X8 letters in English If do not use HMI programming software user also can use PLC s program to control screen to display Ascii code English letter About PLC s commands please refer to Ex1 Ex2 series user s manual The programming software of HMI is EpEditor The programming software of PLC is ExEditor Item No Ep1n314R C T Real Time Clock function R Relay output T Transistor output I O points 8IN 6OUT 3 inches display screen Series Ep1n Ep2n EP300 C Real Time Clock function No input output points 3 inches display screen Series EP314 I O interface circuit diagram Input Specification Item DC input Sink NPN DC input Source PNP