Home
MP10w ES Quick Start Manual
Contents
1. VIPIOES VorTech MP10w ES Propeller Pump AAT ATA MARINE Setup Guide www ecotechmarine com 070113 Customer Support O N Q rat U at O N S O N VO U f Many of the steps in this guide have corresponding how to videos View them on the EcoTech Marine website at ecotechmarine com media gallery video D U O N ASE OT Aa VO rlec N N P 1 The EcoTech Marine Community is another tool for users to troubleshoot and learn about our products For additional information about your VorTech Propeller Pump please visit us at Community ecotechmarine com Propeller Pump UNITED STATES amp CANADA Contact EcoTech Marine directly for all warranty service and returns Visit ecotechmarine com support A Please read this entire setup guide before using your pump By purchasing installing or using this product you are acknowledging that the Limited Warranty on p 19 is part of the sale terms INTERNATIONAL Customer Suppotrt cccccccceeeeeees 1 Short Pulse Mode 14 Contact your local distributor directly for all warranty service and returns Inside the BOX ee ee ee ee eke 2 Long Pulse Mode sees ee see 15 ve eau Oe AA EE PA NE EE ER dior Maintenance sccccccccssseesssseeees 5 Reef Crest Random Mode 16 Installing the VorTech M 4 Additional Modes ccccccceeees 16 u The EcoSmart Driver 8 Lagoonal Random Mode 17 t Ej Mounting the Driver
2. 9 TroubleshootiNg see ees ees 18 Customer Support Operational Modes unueeeeeenennnn 10 Limited Warranty sesse ees ee ee 19 r 1 800 785 0338 Tidal Swell Mode iese esse ee 12 Regulatory Information 20 ECOTEC H service ecotechmarine com or Nutrient Transport Mode e MARINE ecotechmarine com support 4 Inside the Box POWER SUPPLY POWER CORD FOAM GUARD SS Eg N _ Sa MOUNTING TABS X4 VELCRO STRIPS X2 ZIP TIES X4 vor Tech w ECO RB Toon es gt DRIVER DRY SIDE WET SIDE RUBBER SPACER Maintenance Your VorTech Propeller Pump is designed to operate optimally with little attention after initial setup however due to the harsh conditions of a saltwater aquarium and resulting buildup of algae and other organic matter it is advisable to clean your wet side to ensure the longevity of your purchase EcoTech recommends doing a wet side cleaning every 6 to 8 weeks or as necessary This can be accomplished by disassembling the pump s wet side and gently brushing with a soft brush under running water If there is calcium buildup it may be necessary to soak these parts in a mild acid solution such as vinegar Do not use strong acids because these may WET SIDE damage the components DISASSEMBLY WATCH THE VIDEO After cleaning reassemble the wet side ecote ch mp10disassemble Installing the Vor lech STEP 1 Choose Pump Location STEP 4 Place Dry
3. MERCHANTABILITY SHALL APPLY EXCEPT AS REQUIRED BY APPLICABLE LAW ECOTECH MARINE DOES NOT AUTHORIZE ANY PERSON OR BUSINESS ENTITY INCLUDING ITS AUTHORIZED DEALERS TO CREATE FOR IT ANY OBLIGATIONS LIABILITIES OR OTHER WARRANTIES IN CONNECTION WITH THIS PRODUCT ALL WARRANTIES ARE VOID IF THERE IS DAMAGE TO THE VORTECH PROPELLER PUMP THAT IS NOT A RESULT OF A DEFECT IN THE MATERIALS OR WORKMANGHIP THE SOLE AND EXCLUSIVE REMEDY FOR ALL CLAIMS THAT YOU MAY HAVE ARISING OUT OF OR IN CONNECTION WITH YOUR USE OF THIS PRODUCT WHETHER MADE OR SUFFERED BY YOU OR ANOTHER PERSON AND WHETHER BASED IN CONTRACT OR TORT SHALL BE REPAIR OR REPLACEMENT OF THE PRODUCT IN NO EVENT WILL ECOTECH MARINE BE LIABLE TO YOU OR ANY OTHER PARTY FOR ANY DIRECT INDIRECT GENERAL SPECIAL INCIDENTAL CONSEQUENTIAL EXEMPLARY OR OTHER DAMAGES ARISING OUT OF THE USE OR INABILITY OF TO USE THE PRODUCT INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION LOSS OF INFORMATION OR ANY OTHER PECUNIARY LOSS DAMAGE TO YOUR AQUARIUM OR ANY AQUARIUM INHABITANTS OR FROM ANY BREACH OF WARRANTY EVEN IF ECOTECH MARINE HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN NO CASE SHALL ECOTECH MARINE S LIABILITY EXCEED THE AMOUNT YOU PAID FOR THE PRODUCT IF YOU DISAGREE WITH THESE TERMS AND CONDITIONS DO NOT USE THE VORTECH PROPELLER PUMP Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exc
4. This product is for indoor usage only Fran ais Cet quipement est pr vu uniquement pour un usage a l int rieur des b timents English This device is intended for indoor use only European Union Disposal Information This symbol means that according to local laws and regulations your product should be disposed of separately from household waste When this product reaches its end of life take it to a collection point designated by local authorities Some collection points accept products for free The separate collection and recycling of your product at the time of disposal will help conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment FCC Compliance Statement This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Any changes or modifications not expressly approved by EcoTech Marine could void the user s authority to operate the RF module and or the product that incorporates the RF Module The user is cautioned to maintain a 20cm 8 inch spacing from the product to ensure compliance with FCC regulations CE Declaration of Conformity The equipment complies with the RF exposure Requirement 1999 5 EEC Council Recommendation on the limitation of exposure of
5. consistent with the User Manual The VorTech Propeller Pump consists of a wet side operating unit that will be fully submerged in the aquarium and a motor and driver that must not be exposed to water at any time EcoTech Marine s warranty shall not apply i to any damaged VorTech Propeller Pump that has been subjected to accident misuse neglect alteration acts of God improper handling improper transport improper storage improper use or application improper installation improper testing or unauthorized repair ii to any VorTech Propeller Pump where the motor and or driver have been exposed to water or iii to cosmetic problems or defects that result from normal wear and tear under ordinary use and do not affect the performance or use of the product EcoTech Marine s warranty applies only to a product that is manufactured by or for EcoTech Marine and identified by the EcoTech Marine trademark trade name or product identification logo affixed to the product If you notice a problem with your VorTech Propeller Pump do not attempt to repair it yourself Any attempts at self repair shall void this limited warranty EcoTech Marine shall not be held liable for damage to any aquarium aquarium life forms or other personal objects due to improper use of the device If the product develops a covered defect within the one year period EcoTech Marine will at its option either repair or replace the VorTech Propeller Pump without charge provided that t
6. not function properly use one of these support methods e Watch our extensive collection of how to videos These videos are available at ecotechmarine com media gallery video e Visit our support community to ask questions and learn more about your VorTech Propeller Pump at community ecotechmarine com If you are still experiencing problems contact our industry leading customer service at service ecotechmarine com or 1 800 785 0338 Option 2 WAVE MOTION WARNING A The generation of waves within the aquarium places additional stress on the aquarium glass and joints Not all aquariums are designed to withstand this stress and failure of the glass and or joints could result Before generating waves it is recommended that you consult with your aquarium manufacturer to determine if the tank construction is adequate to withstand the additional stress You are also encouraged to assure that your aquarium stand or furniture is adequately stable to withstand this stress A EcoTech Marine DISCLAIMS AND WILL NOT BE LIABLE FOR damage to aquariums or their surroundings water damage or any other consequential damages resulting from wave generation MAKE WAVES AT YOUR OWN RISK 18 Warranty Ecolech Marine warrants to the original purchaser only that the VorTech Propeller Pump will be free from defects in material and workmanship under normal use for a period of 1 year from the date of original purchase if the product is installed and used properly and
7. the general public to electromagnetic fields 0 300 GHz This equipment meets the following conformance standards EN 300 328 EN 301 489 17 This device contains EcoTech Marine s RF Module Part Number 10169 FCC ID VKB271829 IC 7349A 271829 No part of this publication may be reproduced or transmitted in any form or by any means electronic or mechanical including but not limited to photocopying recording information retrieval systems ay or computer network without the written puter net thout the writt C EO as RoHS permission of Ecolech Marine LLC EcoTech Marine and all other EcoTech VorTech Pump can be used in the following countries Marine product names and slogans are trademarks or registered trademarks of EcoTech Marine LLC 2003 2013 by EcoTech Marine LLC All rights reserved
8. wave within your tank To create a wave using Auto Tune Hold SET and OPTION until LEDs move back and forth slowly Press and hold SET until the control dial flashes and then breathes blue indicating Long Pulse Mode When first entering Long Pulse Mode set the maximum pump speed with the control dial and press the SET button to lock it The LEDs will begin to ramp indicating the pulsing frequency between 2 seconds and 2 hours Next use the control dial to adjust the pulse frequency The first six LEDs represent 2 seconds to 2 minutes The seventh through 12th LEDs represent 5 10 20 60 90 and 120 minutes respectively Press and hold SET until the control dial flashes and then breathes pink indicating the wave is saved of User Set Speed Time that the wave has been saved This saved wave will also be used in EcoSmart mode To fine tune the AUTO TUNE wave press MODE to speed up the wave and OPTION WATCH THE VIDEO to slow it down Press SET to save the wave ecote ch autotune 15 Reet Crest Random Mode of User Set Speed Additional Modes Mm All modes are set to default duration speed or percentage of speed Refer to the full manual to learn how to customize these modes ie Reef Crest Random Mode simulates a high energy reef environment It is indicated by both a yellow control dial and the first two blue LEDs illuminated The control dial is used to set the maximum pump speed during this mod
9. Do not use appliance for other than intended use The use of attachments not recommended or sold by the manufacturer may cause an unsafe condition e Do not install or store the appliance where it will be exposed to weather or to temperatures below freezing e Make sure appliance is securely installed before operating it Read and observe all the important notices on the appliance e f an extension cord is necessary a cord with a proper rating should be used A cord rated for less amperes or watts than the appliance rating may overheat Care should be taken to arrange the cord so that it will not be tripped over or pulled e This appliance utilizes extremely powerful magnets that can cause severe personal injury e NEVER place either half of this device near magnetically attractive surfaces or sensitive electronics e The motor and driver can become HOT Be cautious around these surfaces e DO NOT stick fingers or anything else into the propeller NEVER connect the two halves of this device without using the proper spacer 20 RF Module Important Information The product you have purchased contains the Ecolech Marine RF Module part number 10169 This module gives your product the ability to communicate wirelessly to other EcoTech Marine products as well as certain other manufacturer s products that were designed in compliance with the specifications for our RF Module Use of this module in products not consented by EcoTech Marine is prohibited
10. Side on Aquarium e Where the pump output is unobstructed e Place the rubber spacer directly on the wall of the e High enough above the sand bed so sand is not disturbed aquarium at the desired location Figure B e Sufficiently below the surface so air is not sucked e The included rubber spacer must be used between into a vortex the dry side and the aquarium wall for thicknesses of 1 8 8mm and 3 16 65mm STEP 2 Prepare Aquarium The rubber spacer is NOT needed for thicknesses e Use an aquarium scraper to clean the inside surface of of 1 4 6mm or 3 8 10mm the aquarium and a damp cloth to clean the outside Position the dry side so the cord points straight up e Use caution when handling an aquarium scraper in the 12 o clock position Figure e Tie the cord to the mounting tab using a zip tie STEP 3 Attach Mounting Tab Figure C Trim the excess end of the zip tie e Peel backing from the adhesive and place the tab 2 3 above the desired mounting location on the outside of the aquarium Figure A Figure B A Never place the dry side in the aquarium A Failure to use the rubber spacer can damage the pump which will NOT be covered under warranty SET UP YOUR MP10 WATCH THE VIDEO 4 ecote ch mp10setup Installing the Vor lech Continued STEP 6 Attach Wet Side e Place the wet side into the aquarium and allow ALL air to escape from the propeller housing e Carefully align the wet and dr
11. e The pump will change speed freguently and drastically to simulate crashing waves and surging tide Time FEED MODE Press and hold the MODE button for 3 seconds to enter Feed Mode The control dial will blink white and the pump will spin very slowly for 10 minutes default setting and then resume its set mode agoonal Random Mode of User Set Speed BATTERY BACKUP MODE When a Battery Backup accessory is added to the VorTech pump the pump will automatically switch to Battery Backup Mode during a power outage The pump will run at the minimum speed to maximize run time during this critical period Lagoonal Random Mode simulates a low energy lagoon environment It is indicated by a yellow control dial and the third and fourth LEDs illuminated The control dial is used to set the maximum speed of this mode The speed of the pump is changed slowly to recreate the gentle currents of a lagoon Time NIGHT MODE Press and hold the MODE and SET buttons pause and then press and hold the MODE and SET buttons again The control dial will breathe white and spin at 50 power for 10 hours default setting and then resume its set mode 17 roubleshooting In the event of a problem 1 Check that the pump is plugged in and there is power 2 Unplug the pump and check the wet side for damage or obstructions 3 Reconnect the power and reset the driver video ecote ch resetdriver 4 If the pump still does
12. he VorTech Propeller Pump is returned during the warranty period The VorTech Propeller Pump operates at high temperatures and produces forces within the aquarium that can cause extreme loading and fatigue Due to this caution must be used when installing this device on any aquarium Because the construction of aquariums varies from each manufacturer and the operating conditions of each individual aquarist is different there is a possibility that the VorTech Propeller Pump may cause damage to your aquarium Please contact your aquarium manufacturer to determine if your aquarium is properly built and recommended for VorTech Propeller Pump If you notice any damage to your aquarium including but not limited to crazing cracking bending scratching etc immediately discontinue the use of the VorTech Propeller Pump EcoTech Marine will not be liable for any damage caused to your aquarium resulting from the use of the VorTech Propeller Pump To obtain warranty service or technical support please contact EcoTech Marine s customer service department at 610 954 8480 You will receive instructions on how to return the product for repair or replacement To take advantage of this Limited Warranty you will be required to supply an original point of purchase receipt ECOTECH MARINE DISCLAIMS ALL OTHER WARRANTIES WHETHER ORAL OR WRITTEN EXPRESS OR IMPLIED TO THE FULLEST EXTENT ALLOWED BY APPLICABLE LAW NO IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE OR
13. he diagrams above represent the flow pattern and placement of multiple pumps running together 12 in a Master Slave relationship Master Slave relationships Nutrient Transport Mode Nutrient Transport Mode NTM creates circulation in a two phase program The first phase uses wave motion to stir up detritus The second phase follows with a surging motion to move the detritus into the overflow and out of the aquarium This mode promotes maximum health nutrient export and increased growth for sensitive corals such as SPS The control dial is used to adjust the maximum pump speed during this mode x ll a Set Speed 45 75 120 150 Time mins mins mins mins are only available with wireless enabled versions of the VorTech pump For more information MASTER SLAVE and instruction visit our support community WATCH THE VIDEO at community ecotechmarine com ecote ch masterslave 18 Short Pulse Mode 14 of User Set Speed MAKE WAVES WATCH THE VIDEO ecote ch makewave When first entering Short Pulse Mode set the maximum pump speed with the control dial and press the SET button to lock it The LEDs will begin to ramp indicating the pulsing frequency between 0 2 seconds and 2 seconds Next use the control dial to adjust the pulse frequency Press and hold SET until the control dial flashes and then breathes blue indicating the wave is saved Time AUTO TUNE Auto Tune allows you to create a
14. he power cord of this appliance cannot be replaced If the cord is damaged the appliance should be discarded Never cut the cord DO NOT DROP The VorTech Pump is fragile and a fall onto a hard surface can result in permanent damage Damage may include cracking of the ceramic axle within the Wet Side or a loud Dry Side Damage from dropping IS NOT covered under warranty e Position the aquarium stand and tank to one side of a wall mounted receptacle to prevent water from dripping onto the receptacle or plug A drip loop should be employed for each cord connecting an aquarium appliance to a receptacle A drip loop is the part of the cord below the level of the receptacle or the connector if an extension cord to prevent water from travelling along the cord and coming in contact with the receptacle If the plug or receptacle does get wet DON T unplug the cord Disconnect the fuse or circuit breaker that supplies power to the appliance then unplug and examine for presence of water in the receptacle e Close supervision is necessary when an appliance is used by or near children Keep out of reach of young children e To avoid injury do not contact moving or hot parts such as heaters reflectors lamp bulbs and the like e Always unplug appliance from outlet and battery backup when not in use before putting on or taking off parts and before cleaning e Never yank cord to pull plug from outlet Grasp the plug and pull to disconnect e
15. lusions may not apply to you EcoTech Marine s warranty is governed by the laws of the Commonwealth of Pennsylvania excluding its conflict of laws principles and excluding the provisions of the United Nations Convention on Contracts for the International Sale of Goods This warranty gives you specific legal rights and you may also have other rights which vary from state to state Regulatory Information e This product carries an ingress protection rating of IPXO and must not be immersed in water e Danger To avoid possible electrical shock special care should be taken since water is employed in the use of aquarium equipment e DO NOT attempt repairs yourself return the appliance to the manufacturer for service or discard e DO NOT immerse in water If the appliance falls into the water DON T reach for it First unplug it and then retrieve it If electrical components of the appliance get wet unplug the appliance immediately non immersible equipment only e Carefully examine the appliance after installation It should not be plugged in if there is water on parts not intended to be wet e The pump s motor housing and Driver are NOT WATERPROOF water can permanently damage them This damage IS NOT covered under warranty Protect these components from splashes drips or other contact with water e Do not operate any appliance if it has a damaged cord or plug or if it is malfunctioning or if it is dropped or damaged in any manner T
16. ver where it will not get wet using Pump Cable Slot the included velcro strips Figure C Figure B Battery Backup Input P Input ea A The driver is NOT water proof and water damage will NOT be covered under warranty USING di If the control dial is not green check the EcoSmart power cable connections WATCH THE VIDEO Figure C 9 8 ecote ch ecosmartmodes ECOsomart Driver Operational Modes Constant EcoSMART Random o0o e OF O Speed TSM Reef Crest Short Pulse Long Pulse CONTROL DIAL Speed Set Speed Set EcoSMART Random Short Pulse Long Pulse Lagoon Freq Set V Freq Set Hold to save Press to access Hold Feed Mode Hold Power Off d 10 LED bar will indicate change between modes Hold to save Press to access Tidal Swell Mode Tidal Swell Mode TSM creates a harmonic balance reminiscent of the changing flow conditions found in nature Over the course of several hours the flow pattern will go from very chaotic to calm followed by a detritus clearing surge at the very end of the cycle The flow direction will change direction every cycle The control dial is used to set the maximum pump speed during this mode of User Set Speed Same Side as Master 30 60 90 120 150 Time mins mins mins mins mins MASTER SLAVE RELATIONSHIP Multiple VorTech pumps can be set up to run together The colors in t
17. y sides through the glass Figures D e Optional Place the foam guard over the wet side of the pump The foam guard can be used to ensure that delicate marine animals do not get caught in the nozzle Figure D STEP 7 Align Pump e Plug the power supply into the driver If the pump is not already in Constant Speed Mode press the MODE button until the control dial is green e f there is vibration or excessive noise carefully adjust the propeller housing wet side by moving it very slightly left right up or down until the noise vibration is eliminated or minimized Figure E e Rotate the control dial clockwise and set it to the maximum speed indicated by the blue LEDs e Press the MODE button to select the mode of your choice and then turn the control dial to the desired flow rate Figure E dj See page 9 for instructions on mounting the driver The Ecosmart Driver Mounting the Driver vor lect ow 1 Plug the power supply into the driver and then plug the power cord into the outlet Figure A The driver will turn on and be in Constant Speed Mode by default green control dial Wireless Indicator SET Button LED Strip Figure A 2 Observe that the control dial is illuminated green indicating that the pump is powered i Control Dial Control Dia and operational Figure B a gt ad b OPTION Power Button MODE Button peclegh 3 Mount the dri
Download Pdf Manuals
Related Search
Related Contents
KEH-1960 KEH-1940 - Pioneer Europe PulsArc 4000 Microlife A100 Navigation Manual スリムフラッ 卜ーH 調理器 取扱説明書保 FB20005ZEN Descarcă acest fişier Manhattan Multi-Card Reader/Writer OPEN-ROBOT V2 Owner`s Manual (GMS) User Guide for Supervisors and Department Heads of Copyright © All rights reserved.
Failed to retrieve file