Home
Data Sheet
Contents
1. Figure 19 Ready to receive upgrade image file via XMODEM 10 Go to Tools gt Transfer File XMODEM and send the appropriate upgrade image file 11 Once successful change the baudrate of module according to upgraded firmware and the ZigBee module will communicate according to the new firmware For Telegesis R3xx firmware the default baud rate is 19200 8N1 2014 Telegesis UK Ltd 31 ZigBee Communications Gateway telegesis 3 ZigBee Communications Gateway 7 Warranty 1 Telegesis warrants that at the date of delivery the Goods will conform in all material respects to any written specification published or provided by Telegesis and that for the periods set out below in respect of each product type the Goods will be free from defects in workmanship and materials under normal use and service The Buyer must notify Telegesis of any defect in writing Telegesis obligation under this warranty will not arise until the Buyer returns the defective Goods at its own expense and risk to Telegesis Telegesis sole obligation under this warranty shall be at its option to replace or repair without charge such defective Goods or component parts thereof Any replacement of Goods or component parts under this warranty shall not extend the period of warranty beyond that of the goods or component parts so replaced 2 All Hardware is supplied with one year return to base warranty unless indicated otherwise All Software is supplied with a 90 day wa
2. Default Gateway The gateway uses the default gateway specified in this field as default gateway when DHCP option is not selected 2014 Telegesis UK Ltd 20 ZigBee Communications Gateway tel eaesiSis ZigBee Communications Gateway DNS Server The gateway uses the DNS server specified in this field as DNS server when DHCP option is not selected After changing any settings in the IP configuration Leey must be clicked in order to apply the changes in Gateway Following message will be displayed to confirm the change Click refresh to verify if the settings are changed successfully Restoring Factory Defaults The factory settings can be restored by clicking Res Factor The factory defaults can also be restored by combination of hardware button presses as described in Buttons Actions section Following are the factory defaults Default Gateway Configurations 1 Web Terminal Enabled 2 Dialout Disabled 3 Out 1 Address 192 168 204 107 4 Out 1 Port 4094 5 Out 1 Address 192 168 204 107 6 Out 1 Port 4095 7 Secure Connection Disabled 8 Module 1 Enable Enabled 9 Module 1 Port 4096 10 Module 2 Enable Enabled 11 Module 2 Port 4097 12 Time Server 0 uk pool ntp org 0 13 Username admin 14 Password password Default IP Configurations 1 DHCP Enable Enabled 2 Static IP Address 192 168 204 121 3 Subnet Mask 255 255 255 0 4 Default Gateway 192 168 204 10 6
3. The current time of the gateway is displayed in this field when the page is loaded or Reftesh is clicked After changing any settings on the webpage Labeli must be clicked in order to apply the changes to Gateway configuration Following message will be displayed to confirm the change Gateway configurations change successful 2014 Telegesis UK Ltd 19 ZigBee Communications Gateway tel ECsgesIS s ZigBee Communications Gateway IP Configuration a Current IP Configurations Current Configuration IP Address 192 168 204 113 MAC Address 00 21 ED 20 00 00 IP address The current IP address of the Gateway is displayed in this field MAC address The MAC address of the Gateway is displayed in this field b DHCP Configuration DHCP Configuration If this option is enabled the Gateway can acquire IP configurations like IP address subnet mask default gateway and the DNS server dynamically by using DHCP protocol If the DHCP option is not selected then stored Static IP configuration is used to setup the network interface c Static IP Configurations static IP Configuration IP Address 192 168 204 121 Subnet Mask Default Gateway 192 168 204 1 DNS Server 192 168 204 10 IP Address The gateway uses the IP address specified in this field as static IP when DHCP option is not selected Subnet Mask The gateway uses the subnet mask specified in this field as subnet mask when DHCP option is not selected
4. 4 The LED sequence 4 should be indicated by LED panel 5 Navigate to ZigBee Interface Configuration and Select Module 1 as shown below Select Module Module 1 Module Control Serial Settings Reset Module Baudrate Parity Stop Bits 115200 None 1 Y 6 Click to start the bootloader on selected ZigBee module 7 Change the baudrate to 115200 and click Abi 8 On Telegesis terminal hit Enter key to see following prompt atar Bootloader 192 168 204 113 Telegesis Terminal V 4 0 0 TH Aso tote ARA eee File Connection Commands Log Tools Help gt Connection IP Address 1192 168 204 113 Disconnect 4096 Status Connected to 192 168 204 113 4096 ETRX357 Serial OTA Bootloader v01 b01 1 upload ebl 2 run 3 ebl info BL gt m Default Group Figure 18 ETRX3 Bootload prompt 2014 Telegesis UK Ltd 30 ZigBee Communications Gateway 09 1 0 e o o telegesis ZigBee Communications Gateway 9 Press 1 to see character C displayed periodically as shown which indicates the ZigBee module is ready to receive upgrade image file via XMODEM p e lA 192 168 204 113 Telegesis Terminal V 4 0 0 eee Eile Connection Commands Log Tools Help v i 2 gt amp Connection IP Address 192 168 204 113 Disconnect Port 4096 Status Connected to 192 168 204 113 4096 ETRX357 Serial OTA Bootloader v01 b01 1 upload ebl 2 run m Default Group
5. as is given by the manufacturer or supplier of such parts to Telegesis 2014 Telegesis UK Ltd 32 ZigBee Communications Gateway telegesis 3 ZigBee Communications Gateway 5 If the goods are to be manufactured or any process is to be applied to them by Telegesis in accordance with a specification submitted by the Buyer the Buyer shall indemnify Telegesis against all loss damages costs and expenses awarded against or incurred by Telegesis in connection with or paid or agreed to be paid by Telegesis in settlement of any claim which results from Telegesis use of the Buyer s specification including but not limited to any claim for infringement of any patent copyright design trade mark or other intellectual property rights of any other person 6 Telegesis liability hereunder shall be in lieu of any other representation unless fraudulent warranty or condition expressed or implied by law or otherwise with respect to the goods or any liability imposed by common law statute or otherwise and Telegesis hereby excludes all such representations unless fraudulent warranties and conditions and shall not be liable to the Buyer for any loss or damage whatsoever including without prejudice to generality of the foregoing any liability in contract negligence or any other tort for indirect consequential or economic loss or for loss of profit or opportunity of any kind arising directly or indirectly in connection with the contract the Goods
6. to restore the factory default configuration settings on the Gateway using B3 and B1 1 Press and hold B3 2 Then with B3 pressed press and hold B1 for approximately 3 seconds after which the Gateway reboots and LED power up sequence is seen 4 5 2 Gateway reboot Press B3 and hold for 5 seconds to reboot the Gateway 4 5 3 Gateway recovery mode Perform following procedure to put the Gateway in recovery mode 1 Press and hold B3 until gateway reboots 2 At power up hold B2 and wait for 3 seconds 3 The Gateway will be in recovery mode now 4 5 4 Issue ZigBee command Button B2 is used to issue custom ZigBee command to the 1 ETRX3 ZigBee module which can be configured in Button Command section of the Gateway Configurations as shown below So whenever the B2 is pressed the command AT BCAST 00 hello by default is issued to the 1 ETRX3 ZigBee module 2 Recovery mode not implemented in initial release but will be added in subsequent release soon 2014 Telegesis UK Ltd 12 ZigBee Communications Gateway telegesIs ZigBee Communications Gateway 5 Functionality 5 1 Start up Turn ON the ZigBee Communications Gateway by inserting the micro USB power cable into the socket shown in figure 3 The LEDs on the front panel will light up as described in the LED s sequence table Once the Start up LED sequence is complete the gateway will continuously look for an Ethernet link which is indicated by LED sequence 3 Insert the
7. 33 8 Compliance with Laws and RegulatiONS cccocccccoccccoccnccocnnonnnnconnnnnonnnonnnnononnnonnnnnnnnnnonnnnnnnons 34 9 DISCO IA PERA 34 10 DOU Wee LUCO O errante 34 11 SOM AC TMT ONAN ON scan 34 2014 Telegesis UK Ltd 2 ZigBee Communications Gateway telegesis 3 ZigBee Communications Gateway Table of Figures Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Racrade CONS revision ise ito rsada 5 Gateway front VIQW cccccccceecccseceeneeceeeeeeeeteneesseeeeuceteueeseeeeeeeseeeeseeeteneeseeeeseeteneeseeetaeess 7 Gateway without RS232 RS485 back VICW cccceccceeceseeeceneeceeeeeeeeseneeseeeeeeeeteueeseeetaneess 7 Gateway with RS232 RS485 back VIOW oocccoccccoccccocncoccncoonoconononnnonononnnnononocnnnnonnnnonnnnonoss 8 Gateway bottom VW a 9 TOPADO lin aci 9 o AA 10 Devce DISCOVER aca coa 13 Figure 9 Discovery Python Script occccocccccccnccoccnccocncncnnnonocnnonnnnnonnnonnnnnonnnnonnnnnnnnnnnnnrnnnnnnnnnnrnnnnnnnss 14 Figure TOS Discovery QUM eusse ienien e aae E E iE EE EEEE EEEE DiE DTE Ea 14 Figure 11 HTTP server QuthentiCation cccccceccceecceeeseeeseeeeeeeseeeseeseeseeseeseeeteeeteeeseeeseeeseeeseeees 15 Figure 12 GONMQUIATIONS PAC sierici niitin iani airain tatiledsinotinattaviidedsinadsnatiewedadedecd 16 Figure 13 ZigBee Interface Configurations page occccoccncoccncconnncnncnnnnnnnonnnnnnnnnnnnnnnnnnnnnnonnnonronnnanoss 23 Fig
8. AC address 00 21 ed 20 00 00 Ember 4 Printers 1 Unique identifier 00000000000001 Ffff ffff ffFf 021ed2000 Projects IP address 192 168 204 113 L Java NPI387CA1 HP Color LaserJet e AA CP2025n i 14 items Figure 8 Device Discovery 2014 Telegesis UK Ltd 13 ZigBee Communications Gateway tel egesIiS ZigBee Communications Gateway 5 2 2 Discovery on other platforms On other platforms where UPnP services are not available the device can be discovered using the following python script which basically listens to the UDP broadcast on port 14099 by the gateway once every minute import socket traceback commands host Bind to all interfaces port 14099 start a udp socket server to listen on port 14099 S SOCKET SOCKET SOCKET AF_INEL SOCKET So0CK DGRAM 1 34SOSLSOCKOPt socket OL SOCKET SOCKets gt 0 REUSEADDR 1 5 388 USOCKOPT SOCKST SOL SOCKET SOCKEGL 50 BROADCAST 1 s bind host port print Waiting for Telegesis Gateway while 1 trv message address s recvfrom 8192 print Telegesis Gateway Found on IP Address Sr address 0 except KeyboardiInterrupt SystemExit raise Figure 9 Discovery Python Script Run the above script from command line and the output window would show the IP addresses of the ZigBee Communications Gateways in the network as shown below EM Command Prompt udpserv py hc Di i Xl C gt udpsery py Waiting for Te
9. Ethernet cable in the RJ45 socket shown in figure 3 The gateway will try to obtain an IP address by using DCHP by default DHCP is enabled but the user can also set static IP address for the Gateway Once an IP address is allocated successfully the LED sequence 4 is displayed on the LED panel 5 2 Gateway Discovery 5 2 1 Discovery on a windows 7 PC Gateway implements UPnP discovery service so the user can directly go to Network settings and look for devices under Network Infrastructure category The Gateway will show up as ZigBee Communications Gateway as shown below Navigate to properties by right clicking on the device to view the device properties Browse to the IP address shown in the device properties or alternatively double click on the device to navigate to the webpage hosted by Gateway ZigBee Communications J es W Network Device gt ZigBee Communications Gateway Device Details Manufacturer Telegesis UK Ltd http www telegesis com s i GO Network gt v 69 Search Network z _ gt a a Model GW 357 http 192 168 204 113 Organize y Network and Sharing Center Add a printer Ss Model number GW 357 10 0 0 1 0 A A Favorites Computer 12 Device webpage http 192 168 204 113 conf html W Desktop i 4 Network Infrastructure 1 ly Downloads Troubleshooting Information gt Recent Places Serial number 00000000000001 eagle M M
10. The SSL is not implemented in current release 2014 Telegesis UK Ltd 21 ZigBee Communications Gateway tel ECsgesIS s ZigBee Communications Gateway Changing the Admin Password User can change the Gateway s default password by clicking Change Password which will display following fields on the configurations page Fill in all the fields and hit change to apply new password Old Password New Password Max 9 chars Retype New Change Once the password is changed successfully the following message will be displayed Password can also be reset to factory default by restoring factory default configurations mentioned in Buttons Actions 2014 Telegesis UK Ltd 22 ZigBee Communications Gateway telegesisi ZigBee Communications Gateway ZigBee Interface Configurations fo ZigBee Communications Gateway tele ges SSE ETRX357 To Ethernet O Warming ZigBee Interface Configuration Select Module Please consult the user Module 1 manual before makin n any changes to the s Module Control Serial Settings configuration Incorrect ResetModule Baudrate Parity Stop Bits configuration may make the Gateway Start Bootloader 19200 None 1j Apply Refresh inaccessible over the Ethernet or ZigBee Note The Serial Port settings only apply to the Gateway For correct operation the Serial Port settings of the ETRX3 module must be changed to match the new Gateway setting before changing the G
11. ateway parameters Visit Telegesis UK Ltd website forthe Users Manual Copyright 2012 www telegesis com Figure 13 ZigBee Interface Configurations page The Gateway comes with Telegesis ZigBee AT commands Firmware programmed onto the assembled ETRX3 ZigBee module This firmware communicates at baud rate settings of 19200 8N1 The ZigBee Interface Configurations page is useful to change the serial settings of the gateway serial ports connected to the ETRX3 ZigBee modules This page also provides the options to reset the selected ETRX3 ZigBee module and to start the bootloader a Select Module This field selects the ETRX3 ZigBee module to apply the settings to there can be two module as per the model number of gateway b Module Control Reset Module Click _Reset Module _ for gateway reset the selected ETRX3 module Start Bootloader Click StartBootioader to start the bootloader on selected ZigBee module The standard AT Command firmware has serial Bootloader which can be used to upgrade the ZigBee firmware in the selected module Process of upgrading ETRX3 ZigBee firmware in standard Gateway is described in the Appendix A The bootloader is initiated by holding down the PA5 pin of the EM35x and then issuing a hardware reset to the module c Serial Settings Select the serial settings for the selected module and click L to apply the settings Please refer AT commands documentati
12. ause shall only be varied or extended where Telegesis has granted the Buyer an Extended Warranty 7 1 Caution The user must read through the user manual and learn to use the equipment appropriately Telegesis UK Ltd will not accept any liability arising from using the equipment in the manner not specified by the documentation accompanied by the equipment 7 2 Cleaning Dust or wipe only with damp cloth do not allow moisture to penetrate the enclosure Do not use aggressive cleaning agents 2014 Telegesis UK Ltd 33 ZigBee Communications Gateway telegesi o Ate o d gt e gt ote ZigBee Communications Gateway 8 Compliance with Laws and Regulations The Buyer hereby certifies that no Goods will be exported directly or indirectly outside the United Kingdom unless where necessary the appropriate prior authorisation to such export has been obtained from the Department of Trade and Industry London and or where applicable the Office of Export Administration of the US Department of Commerce 9 Disclaimer Product and Company names and logos referenced may either be trademarks or registered trademarks of their respective companies We reserve the right to make modifications and or improvements without prior notification All information is correct at time of issue Telegesis UK Ltd does not convey any license under its patent rights or assume any responsibility for the use of the described product This device
13. be automatically forwarded to the ETRX3 ZigBee module e RS232 RS485 Port Configuration This option is only available on GW357 gateway models which have the RS2321R5485 option see the order codes table Here the user can select the RS232 and RS485 port settings Note it is recommended although not a requirement that the RS232 RS485 port on the gateway and the ETRX3 ZigBee module have the same baud rate The gateway has a limited capacity to buffer messages ensuring the baud rates are the same removes the potential for a buffer overflow in the RX or TX paths 4 The SSL is not implemented in current release gt This option only available in Gateway models with two ZigBee modules on board Please refer order codes 2014 Telegesis UK Ltd 18 ZigBee Communications Gateway tel ECsgesIiS s ZigBee Communications Gateway f Discovery Discovery Enabled This option is enables the Gateway to send discovery broadcasts by UDP on port 14099 once every minute This option is enabled by default g Button Command Button Command AT PJOIN This is a command string that will be sent to the 1 ETRX3 ZigBee module each time the Button 2 B2 is pressed h Gateway Time Gateway Time Time Server 0 uk pool ntp org Current Time 20 08 2013 11 15 33 DD MMAYYY HH MM SS Time Server The Gateway implements SNTP client which can update Gateway time from a valid time server specified in time server field Current Time
14. d to the ZigBee module via Web Terminal if this status is been displayed Terminal Enabled Status Terminal Enabled Comms Ok Time 21 01 2013 01 15 07 When the Web Terminal connects successfully to the ZigBee module above status will be displayed The Gateway time will also start updating once every second Now the user may enter an AT Command in ZigBee input box and click L 88n4 issue the command to the ZigBee module and expect the response in approximately one sec Please refer AT commands documentation at Telegesis document centre 19 Note Pressing Enter Key on Keyboard will NOT send the command but will refresh the page 2014 Telegesis UK Ltd 24 ZigBee Communications Gateway O 6 0 an ote amp o telegesisii ZigBee Communications Gateway Firmware Upgrade The Gateway firmware can be updated over Ethernet To perform Gateway firmware upgrade navigate to http lt gateway_ip address gt bootload html page which looks like below oo ZigBee Communications Gateway t e e 2 es S33 E ETRX357 To Ethernet O Warning Stored Image Info Upload Images Select Uplaod Image Type Image Header GW357_APP_IMAGE Gateway Image Please consult the user Firmware Version 00010001 manual before making O Ca ae any changes to the Image Size 0004E004 bytes Ghansekies GW357_BRD 2_K60 img configuration Incorrect configuration may Update Gateway Upload New Image make
15. et Layer DNS Domain Name System SNTP Simple Network Time Protocol DHCP Dynamic Host Control Protocol IP Internet Protocol MAC Media Access Control 2014 Telegesis UK Ltd 4 ZigBee Communications Gateway telegesisiz ZigBee Communications Gateway 3 Package Contents The package contains the following items Figure 1 Package contents a ZigBee Communications Gateway b Micro USB power cable c Mounting screws 2014 Telegesis UK Ltd 5 ZigBee Communications Gateway tel CSEslis s ZigBee Communications Gateway 4 Specifications 5Volts 500mA via USB Micro Connector Charging source should be current limited Ethernet RJ45 10 100Mbps Power Over Ethernet 802 3af Compliant Class 1 Device optional RS485 RS232 Baud rate 2400 4800 9600 19200 38400 57600 115200 Parity none odd even Stop bits 1 or 2 RS485 120Q termination resistor built in 4 1 Order Codes 4 2 Examples GW357 11 P W 1 8 Gateway with 2xETRX357 module Power over Ethernet WiFi RS232 RS485 and an 8MB SD Memory Card GW357 1 Basic Gateway with 1xETRX357 module GW357 30 0 0 1 Gateway with 1xETRX357 LRS and RS232 RS485 2014 Telegesis UK Ltd 6 ZigBee Communications Gateway 6 r tto D 0 o telegesisii os ZigBee Communications Gateway Layout e i i 2nd ETRX3 Status LED Interface Activity LED Gateway Activity LED Link Status LED 1st ETRX3 Status LED Figure 2 Gatewa
16. guration Please consult the user manual before making any changes to the configuration Incorrect configuration may make the Gateway inaccessible ower the Ethernet or ZigBee Visit Telegesis UK Ltd website for the Users Manual 2014 Telegesis UK Ltd IP Configuration Current Configuration IP Address 192 168 204 144 MAC Address 00 21 ED 20 03 BE DHCP Configuration DHCP Enable Static IP Configuration IP Address 192 168 204 121 Subnet Mask 255 255 255 0 Default Gateway 192 168 204 1 DNS Server 192 168 204 10 Reboot Gateway Password Gateway Configuration Web Terminal Enable Dialout TCP Sockets Enable Fl Module 1 Out Address 192 168 204 107 Module 1 Out Port 04094 Secure Connection E Dialin TCP Sockets Module 1 Enable Module 1 Port 04096 RS 232 R5 485 Tunnelling RS 485 Module 1 R5 232 Module 1 L RS 485 Port Configuration Baud Rate Parity stop Bits 115200 None 1 RS 232 Port Configuration Baud Rate Parity Stop Bits 115200 None 1 Discovery Enable Button Command AT BCAST 00 Gateway Time 0 uk poolntp org 10 02 2014 13 19 34 DMM yy HH MM SS Time Server Current Time Copyright 2012 werw telegesis com Figure 12 Configuratio
17. legesis Gateway Telegesis Gateway Found on IP Address 192 168 204 113 Telegesis Gateway Found on IP Address 192 168 204 104 Figure 10 Discovery Output 2014 Telegesis UK Ltd 14 ZigBee Communications Gateway telegesisiz ZigBee Communications Gateway 5 3 Gateway Webserver ZigBee Communication Gateway hosts a http webserver to serve webpages which help the user to configure the Gateway and communicate with the ZigBee device via a simple web interface 5 3 1 Authentication The http webserver is protected by basic authentication hence a valid username admin and password password must be provided when prompted to access the webpages The password can be changed through the GW357 Configuration webpage as explained in the later section Authentication Required The server http 192 166 204 113 80 requires a username and password The server says Authorize User Name admin Password s Figure 11 HTTP server authentication 2014 Telegesis UK Ltd 15 ZigBee Communications Gateway telegesisi3 5 3 2 Web Pages Following web pages are served by the http web server on the ZigBee Communications Gateway GW357 Configuration The Gateway configuration page is the main page of the http webserver This page provides access to the configuration parameters of the Gateway telegesisi ZigBee Communications Gateway ae ZigBee Communications Gateway ETRX35 To Ethermet ss GW357 Confi
18. ng in the micro USB cable in the socket provided as shown in figure 3 with power source as specified in the Specifications Selected models of gateway incorporating Power over Ethernet PoE can be powered on using the PoE injector through RJ45 cable 2014 Telegesis UK Ltd 10 ZigBee Communications Gateway tel egesIS s ZigBee Communications Gateway 4 4 LED Indicators 2nd ETRX3 Status LED Interface Active LED Gateway Activity LED Link Status LED 18 ETRX3 Status LED Sequence Gateway Interface Activity LED Active Number LED ON Red Blinking OFF ON Green Amber for 5 sec All LEDs will turn ON and then following blink one after the other twice except for the ETRX3 Status LEDs which are controlled by ETRX3 ZigBee modules Blinking Amber Green OFF Ethernet link inactive Ethemetlink active Any socket connected to Green either ZigBee module OR Web Terminal connected Any communication with Blinking ZigBee modules Amber OR Any communications on Ethernet lines Table 2 LED Sequence table 2014 Telegesis UK Ltd 11 ZigBee Communications Gateway tel EsgesIS s ZigBee Communications Gateway 4 5 Buttons Actions The Gateway has three hardware buttons as shown in the Layout which can perform multiple functions as described in this section 1 Button 1 B1 2 Button 2 B2 3 Button 3 B3 4 5 1 Restore factory defaults Follow the following procedure with buttons in order
19. ns Page 16 ZigBee Communications Gateway tel Csesis s ZigBee Communications Gateway Gateway Configuration a Web Terminal Web Terminal Enable This option enables or disables the access to ZigBee module via the web terminal The Gateway provides an access to the ZigBee module via Web Terminal page which can be used to issue commands to the ZigBee module and monitor the response of the module The Web Terminal only supports communication in ASCII Default value is enabled b Dialout TCP Sockets Dialout TCP Sockets Enable Out 1 Address 192 168 204 107 Out 1 Port 04094 Out 2 Address 192 168 204 107 Out 2 Port 04095 Secure Connection Enable The Gateway can establish an outgoing TCP socket connections to a specified dialout addresses and port numbers This option can enable or disable the outgoing socket connections for both the ZigBee modules Default value is disabled Out 1 Address The address specified in this option is used by the gateway to establish the outgoing socket connection for the 1 ETRX3 ZigBee module The dialout address can either be an IP address or a host name Out 1 port This item specifies the port number for the dialout connection from 1 ETRX3 ZigBee module Out 2 Address The address specified in this option is used by the gateway to establish the outgoing socket connection from the 2 ETRX3 ZigBee module The dialout address can either be an IP address or a host name Ou
20. on at Telegesis document centre 8 The Serial Port settings only apply to the Gateway For correct operation the Serial Port settings of the ETRX3 module must be changed to match the new Gateway setting before changing the Gateway parameters 2014 Telegesis UK Ltd 23 ZigBee Communications Gateway telegesisi ZigBee Communications Gateway Web Terminal we ZigBee Communications Gateway vo te e ge SIS ETRX357 To Ethernet O Warning ETRX3 Web Terminal Terminal Status an Terminal Enabled Comms Ok Time 27 08 2013 11 52 53 lt Gateway Time manual for description ati ofAT Commands and their usage Telegesis ETRX357 R308C Visit Telegesis UK Ltd 000D6F0001600F8B website for the Users Manual OK ZigBee output ZigBee input Send Clear Copyright 2012 www telegesis com Figure 14 Web Terminal page The Web Terminal is a simple web interface to communicate with the 1 ETRX3 ZigBee module on the Gateway User can issue AT Commands to the module in ZigBee input command box click Send and monitor the response in the ZigBee output window The Terminal status shows the current status of the web terminal and the Gateway time is also displayed in the top right of the ZigBee output window Terminal Disabled Status Terminal Disabled Comms Failure Time 00 00 00 If the Web Terminal option is disabled in the Configurations page Terminal status as shown above will be displayed No commands can be issue
21. on reboot the gateway will validate the Bootloader Image stored by the image upload process mentioned above and updates the recovery bootloader firmware if a valid image is present Wait for Serial Commands The Gateway can accept some serial commands at start up available only on models with RS232 RS485 port present If this flag is enabled the gateway will wait for 5 sec to accept any serial commands on the RS232 lines and then jump to the main gateway application Enable the appropriate flags and click Update flags and Reboot buttons to upgrade the gateway with stored image Upgrading may take few minutes be patient and do not interrupt the upgrade process until power up sequence is indicated on the LED panel The upgrade process will be indicated by blinking of gateway activity LED 2014 Telegesis UK Ltd 27 ZigBee Communications Gateway telegesis ZigBee Communications Gateway Support Support link will redirect to telegesis Support page on the internet http www telegesis com support Logout Logout will end current session and Logged out successfully message will be displayed and the user will need to authenticate with username and password at the next login oo ZigBee Communications Gateway tele ges NE ETRX357 To Ethernet O Warming Logged out Successfully Please consultthe user manual before making any changes to the configuration Incorrect configuration may make the Gateway inaccessible over
22. or otherwise except insofar as any exclusion or limitations of Telegesis liability hereunder is prohibited void or enforceable by law 7 Telegesis shall not be responsible in any manner whatsoever for any software information or memory data stored on or integrated with any of the Goods returned to Telegesis for repair or replacement under this warranty 8 Without prejudice to any other provision in these Terms in any event Telegesis total liability for any one claim or for the total of all claims arising from one act of default on Telegesis part whether arising from Telegesis negligence or otherwise shall not exceed the purchase price of the Goods the subject matter of any claim but nothing herein shall limit or exclude Telegesis liability for death or personal injury caused by Telegesis negligence or Telegesis liability for fraudulent misrepresentation 9 Where the buyer deals as a consumer within the meaning of the unfair contract Terms Act 1977 nothing in these terms shall restrict or exclude any liability of Telegesis for breach of its implied undertakings as to conformity of the goods with description or sample or as to their quality or fitness for the purpose 10 In the case of a consumer transaction nothing in these terms shall affect the statutory rights of the Buyer as defined in the Consumer Transaction Restrictions on Statements Order 1976 as mentioned 11 The period or terms of the warranty contained in this cl
23. rranty period 3 With respect to any computer software comprised in the Goods supplied by Telegesis any defects arising after expiry of the warranty period referred to above should be notified to Telegesis in writing Telegesis may at its discretion endeavour to correct any such defects but Telegesis gives no warranty that any such defects can be corrected or that defects will be corrected within a particular time 4 Telegesis shall not be liable hereunder a If the Goods alleged to be defective have been repaired or altered by any person other than Telegesis designated personnel or authorised representative or other person approved by Telegesis in writing or b Where testing or examination by Telegesis reveals any alleged defect in the goods to have been caused by the buyers misuse neglect improper installation failure to follow instructions whether oral or in writing or the supply by the Buyer of incorrect or inadequate instructions or information with the regards to the design of any Goods or to have been caused by any similar equipment to which the Goods are attached or in which the Goods are incorporated or any cause beyond the range of intended use of the Goods or by accident fire or other hazard or c Where component parts alleged to be defective were not manufactured by Telegesis but were included in the Goods at the request of the Buyer in which case the Buyer shall only be entitled to the benefit of any such warranty or guarantee
24. should not be used without proper consideration and design of associated system architecture and redundant safety features in applications where failure may result in death or injury The manufacturer accepts no responsibility for injury death or loss human or material caused by the use or misuse of this device 10 Software License This product is licensed under the wireless network patent portfolio license for use by a consumer or other uses for which there is no remuneration Any other use of this product in any manner is not licensed and is expressly prohibited without a license under applicable patents in the wireless network patent portfolio which license is available from MPEG LA LLC 4600 S Ulster St Suite 400 Denver Colorado 80237 U S A see http www mpegla com 11Contact Information Website www telegesis com E mail sales telegesis com Telegesis UK Limited Abbey Barn Business Centre Abbey Barn Lane High Wycombe Bucks HP10 9QQ 2014 Telegesis UK Ltd 34 ZigBee Communications Gateway
25. t 2 port This item specifies the port number for the dialout connection from 2 ETRX3 ZigBee module 3 This option only available in Gateway models with two ZigBee modules on board Please refer order codes 2014 Telegesis UK Ltd 17 ZigBee Communications Gateway telegesis 3 ZigBee Communications Gateway Secure Connection This option enables the SSL on the outgoing socket connection c Dialin TCP Sockets Dialin TCP Sockets Module 1 Enable Module 1 Port Module 2 Enable Module 2 Port Module 1 Enable The Gateway also allows an incoming TCP socket connection on a specified port which enables access to the 1 ETRX3 ZigBee module Module 1 Port The IP port number to access the 1 ETRX3 ZigBee module via incoming TCP socket Module 2 Enable The Gateway also allows an incoming TCP socket connection on a specified port which enables access to the 2 ETRX3 ZigBee module Module 2 Port The IP port number to access the 2 ETRX3 ZigBee module via incoming TCP socket d RS232 RS485 Tunnelling This is only available on GW357 gateway models which have the RS232 RS485 option see the order codes table A Module 2 check box will also be present if your GW357 has a second ETRX3 ZigBee module fitted This option creates a direct connection between the RS232 or RS485 port on the gateway and the ETRX3 ZigBee module The GW357 doesn t support addressing in multidrop networks Any data received on the RS485 port will
26. t secondary bootloader when gateway is rebooted with Update Bootloader flag is enabled c Configuration Settings Image All the configurations settings mentioned in Configurations page can be updated by this image type The settings will get applied after the gateway is rebooted No flag is necessary to be enabled for the configuration settings to be update Image Upload Process Click Choose File which opens a dialogue box to navigate to the image navigate to appropriate file and click open Now click Upload Newimage a pop up box will open to confirm correct file is uploaded Click OK to proceed Gateway activity LED will be blinking while the file is being transferred If the image is uploaded and stored successfully in Gateway FW image sent successfully message is displayed in a new tab in the browser 11 Recovery bootloader mechanism is not implemented in the initial release but will be implemented in subsequent release soon 2014 Telegesis UK Ltd 26 ZigBee Communications Gateway tel Csesis s ZigBee Communications Gateway Update Flags and Reboot Update Gateway Disabled Update Bootloader Disabled Wait for Serial command Disabled Update flags and Reboot Update Gateway If this flag is enabled upon reboot the gateway will validate the Gateway Image stored by image upload process mentioned above and updates the gateway firmware if a valid image is present Update Bootloader If this flag is enabled up
27. the Ethernet or ZigBee Visit Telegesis UK Ltd website for the Users Manual Authentication Required The server http 192 168 204 113 80 requires a username and password The server says Authorize User Name Password Figure 16 Logout page 2014 Telegesis UK Ltd 28 ZigBee Communications Gateway 09 9 lt telegesis o gt gt gt o ZigBee Communications Gateway 6 Appendix A 6 1 Bootloading ETRX3 ZigBee module The procedure to upgrade firmware on ETRX3 module over a TCP socket is as described below 1 For this example assume the firmware of 1 ETRX3 ZigBee module is to be updated remotely over a TCP socket 2 Make sure dialin socket is enabled for the 1 ETRX3 ZigBee module as shown below Dialin TCP Sockets Module 1 Enable Module 1 Port Module 2 Enable Module 2 Port 3 Connect to the Gateway s dialin socket for the 1 ETRX3 ZigBee module using Telegesis terminal Version 4 or higher as shown below mere 192 168 204 113 Telegesis Terminal V 4 0 le eS File Connection Commands Log Tools Help i ja 2 gt Connection IP Address 192 168 204 113 Disconnect Port fao9s Status Connected to 192 168 204 113 4096 Default Group Figure 17 Dialin socket connection 2014 Telegesis UK Ltd 29 ZigBee Communications Gateway e 1 telegesisi te ZigBee Communications Gateway
28. the Gateway Disabled F inaccessible over the Ethernet or ZigBee Update Bootloader Visit Telegesis UK Ltd Disabled website for the Users Wait for Serial command Manual Disabled 2 Update flags and Reboot Copyright 2012 www telegesis com Figure 15 Firmware Upgrade page Stored Image Info stored Image Info Image Header GWS35 _APP_IMAGE Firmware Version 00010001 Image Size 0004E004 bytes This section gives the information of the Gateway firmware image stored in the Gateway Image Header Each image stored in the Gateway has an Image Header for identifying the type of image This field displays the image header of selected Image type Firmware Version This field displays the firmware version of image stored Image Size This field displays the size of stored image in bytes 2014 Telegesis UK Ltd 25 ZigBee Communications Gateway tel Csesis s ZigBee Communications Gateway Upload Images Upload Images select Uplaod Image Type Gateway Image Ka Choose File GW357_BRD Z_K60 img Upload New Image Select Upload Image Type Select the type of image to be uploaded to the Gateway Currently Gateway supports three types of images a Gateway Image This is the gateway upgrade image which will replace the current Gateway firmware when gateway is rebooted with Update Gateway flag enabled b Bootloader Image This is the recovery bootloader upgrade image which will replace the curren
29. ure 14 Web Terminal page RA O o eE a eeansemessaeneinaseceteanoesdacouee 24 Figure 15 Firmware Upgrade page ooccccccccoccccccnoconocncnononcnnnnonncnonnnnnnnnonnnnnnnnnnnrnonnnnnnnnonnnnnnnnnnnnns 25 Figure 16 Eos 018110 PAQO csiscscstsaiencotsancidesididacntsaecicntiiideowtsaesicetsuideoutshishontiuidsuutshictouisdideuudsidiceisuideouien 28 Figure 17 Dialin socket CONNECTION ccccccceeeceeeceeeceeeseeeeeeeceueceeeseeseeseeseeeseeeteeeteeeseeeteeeseeeseeees 29 Figure 18 ETRX3 Bootload prompt ccoocccoccccncnconcncncnccncncnncononnnoncnnnnnonnnnnnnnnnnnnnnnrnnnnnnnnnnonnrnnnanennens 30 Figure 19 Ready to receive upgrade image file via XMODEM ooncccccnccccncccnccncnconnncccnccncnnonnnnnnnss 31 2014 Telegesis UK Ltd 3 ZigBee Communications Gateway tel eagesiSis ZigBee Communications Gateway 1 Change Log Table 1 Version Comments Aug 28 2013 Initial draft Nikhil Sarnaik Oct 13 2013 Button command modified Nikhil Sarnaik 3 Jan 22 2014 Added Change Log Added pinout for RS232 485 Nikhil Sarnaik ports Added configuration options for Alex Wood RS232 R5485 ports Corrected order codes Restore factory defaults by button updated April 22 2014 Added license message Nikhil Sarnaik 2 Abbreviations PoE Power over Ethernet LED Light Emitting Diode HTTP Hyper Text Transfer Protocol UPnP Universal Plug and Play UDP User Datagram Protocol TCP Transmission Control Protocol SSL Secure Sock
30. y TG PM 510 ZigBee Communications e Gatewa telegesis y ZigBee Communications Product Manual 0510r4 Gateway Telegesis ZigBee Communications Gateway Product Manual Rev 4 Date April 2014 tel CSsesis s ZigBee Communications Gateway Table of Contents TT ERAN SIDO tr ee ee ee ee eee 4 2 ADO EVANS ana 4 A E AEA E 5 Ar P CON e a e a e a a a a e a a a ii 6 Al a A PPP A 6 A PP A O PO PES ES PROC OSO EE E EERE S 6 A O ea o OOO o O O 10 4A CED Indicators eniri ica 11 AS BUILOASACH N Sisi TN 12 4 5 1 ola arial e A oo A 12 4 5 2 Gateway reboot oocccoccccccccnccccncnconcncnanonnnnnoncnnnnnonnrnnnnrnnnnnnrnrnnnnnnrnnnnrnrnnnnnnrnrnrrnrnrnnennenns 12 4 5 3 Gateway recovery MOG occccoccnccccnccoccnocncnccnnnnnoncnonnnnnnnnnnnnnnnnnonnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnos 12 AO ISSUE ZIG BCS COMIMANA mario 12 SD FUNCIONOU iicsapesisctapesnciaprsiicsaanten tins E A A A 13 BA AUD 13 2 QdleWway DISCO VO Nero 13 5 2 1 Discovery on a windows 7 PC o coccccccccnccccncnconcnnnnnnnncnonnnonnnnnnncnnnnnnnnrnnnnrnnnnnnnnrnnnanennnns 13 5 2 2 Discovery on other platforms essa osea cunas dean adecco 14 do Gateway VV eDSENVGI mn 15 5 3 1 PUT ENUCATION A A E O UC 15 Eo A e 16 6 Appendix sica as 29 6 1 Bootloading ETRX3 ZigBee MoOdule oocccoccccccccccnccncnccncononnconcncnnnonnnnnonrnonnnnnnnnonnrnnnnnnnnnnos 29 Me Cuchi CO PPP eo ee ee ee re er ee 32 T A o OOO A 33 A EANN gee ame eee en eee ne eee ee eee aera eee ne ee eee
31. y front view Ethernet connector RJ45 Micro USB power socket Button 2 B2 Figure 3 Gateway without RS232 RS485 back view 2014 Telegesis UK Ltd 7 ZigBee Communications Gateway 00 0 o 0 telegesiSis ZigBee Communications Gateway RS232 TX Ethernet connector RJ45 GND Micro USB power socket RS232 RX Button 2 B2 RS485 D RS485 D Figure 4 Gateway with RS232 RS485 back view Compatible connectors for RS232 RS485 port MULTICOMP MCO00099 MULTICOMP MC000107 MULTICOMP MC000115 2014 Telegesis UK Ltd 8 ZigBee Communications Gateway Kidd 100 O b telegesis 5 i ZigBee Communications Gateway Anti slip pads Mounting holes SS Button 1 B1 Opening for battery and SD Button 3 B3 card holder LT Anti slip pads Figure 5 Gateway bottom view ZigBee Communications Gateway Power suppl s hues Rating S0OmA max S5VDC eee ratings Contains FCC ID S4GEMISXA te egesi 5 IC 8735A EM35XA Consult user manual before use Only replace with CR2032 3V Battery Gateway MAC address MAC 00 21 ED 20 00 21 Figure 6 Top label 2014 Telegesis UK Ltd ZigBee Communications Gateway telegesis Manufacture date Gateway serial number Gateway model number 4 3 Power ZigBee Communications Gateway Date 201331 iF Serial 000040 rat P N GW357 10 0 0 0 0 Figure 7 Bottom label The Gateway can be powered ON by pluggi
Download Pdf Manuals
Related Search
Related Contents
Bedienungsanleitung5089 CROSSTRAINER USER'S MANUAL Typ/Type 8485 Erdungsüberwachungsgerät Grounding vacon®100 x Manuel de l`applicatif pour la pompe solaire Compliance Forms Rando/explo Préparation Copyright © All rights reserved.
Failed to retrieve file